HomeMy WebLinkAboutSOUTHFORK WEST BLK 6 LT 3
Rick Mystrom.
Mayor
Municipality of Anchorage
Department of Health and Human Services
825 "u' Street
P.O, Box 196650 Anchorage. Alaska 99519-6650
http://www.ci.anchorage.ak.us
July 8, 1999
Michael & Karen Boylan
PO BOX 241283
Anchorage, AK 995241283
Subject:
SOUTHFORK WEST BLK 6 LT 3
Permit # SW980235 PID # 078-031-12
The subject permit, issued 7/15/98 by tNs office for a single family well and/or on-site
wastewater system, is due to expire as of 7/15/99.
If you have drilled the well, a well log must be sent to this office for documentation of the
installation and to close the permit.
Ifa licensed Professional Engineer has inspected the installation of the on-site wastewater
system, the original as-built inspection report must be sent to this office for review,
approval and documentation. All inspection reports must be submitted witNn 30 days of
construction completion.
A new permit must be obtained from this office for a well and/or on-site wastewater
system NOT installed by the expiration date. However a new permit can be issued free of
charge for a second year if the application for the renewal is received on or before the
date of expiration of the original permit for wNch a fee was paid.
When applying for a new permit after the original permit has expired or for more than a
second year, the fees are: $320.00 for an on-site wastewater permit and $120.00 for a well
permit.
If you have any questions, please call this office at 343-4744.
Program Manager
On-site Services
enc: Copy of Permit
MUNICIPALITY OF ANCHORAGE
Depatfment of Health and Human Services
On-Site Services Program
825 L Street, Room 502
P.O, Box 196650, Anchorage, AK 99519-6650
(907) 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT
Initial
Date Issued: Jul 15, 1998
Expiration Date: Jul 15, 1999
Permit Number: SW980235
Legal Description: SOUTHFORK WEST BLK 6 LT 3
Design Engineer: Tobben Spurkland, P.E.
Owner Name: PAUL C. WEISNER
Owner Address: PO BOX 772752
EAGLE RIVER, AK 99577-2752
ParcellD: 078-031-12
Site Address:
Lot Size: 149684 SQ. FT.
Total Bedrooms: 3 Permit Bedrooms: 3
This permit is for the construction of:
[] Disposal Field [] SepticTank [] Holding Tank [] Privy
[] Private Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling
(907) 343~4744( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
Issued By:
Date: 7 -',~'~ ~~'
Date:
203 W 15th. Avenue, Suite 203
ANCHORAGE, ALASKA 99501
(907) 279-3916
Fax (907)-276-6013
SEPTIC SYSTEM DESIGN
LOT 3 BLOCK 6 SOUTH FORK WEST
PAUL WEISNER
Municipality of Anchorage
Department of Health and Social Services
820 1 Street
Anchorage, Alaska 99501
June 12, 1998
We are submitting an application for the installation of a well and septic system for this lot. The
submittal consist of three (3) drawings showing the present improvements on the lot and the
adjoining properties, (sheet 1/3), the proposed improvements of the lot, of which only the well
and septic system are subject to this permit application, (sheet 2/3), and a schematic of the septic
system, (sheet 3/3). Soil logs and percolation tests of applicable testholes are also enclosed.
The septic system design is based on the following:
Ground Water at 5 ff.
Use 1250 STEP
Use 5-foot WIDE TRENCH WITH INFILTRATORS
Soil Rating. 10 mhKin = 1.6 gal per sq.fl/day
No. of Bedrooms 3
Required Area per Bedroom: 150/0.8 - 187.5 sq.ff..
Total area required: I87.5 x 3 = 562.5 sq ft
Length of Trench: 562.5 /5 -- 112.5 ft
SYSTEM CONFIGURATION
1250 STEP
5-FOOT WIDE
TOTAL LENGTH 2 x 60 - 120 FT
TOTAL WIDTH 5 FT
TOTAL DEPTH I FT
ROCK DEPTH NONE
COVER 3 FT
The installation of this septic system will not prevent wells from be installed on the adjacent lots.
There are no developed or natural surface / sub surface drainage courses on this or the ad.~acent lots.
The proposed septic system will not change the general slope of the area. Ponding and/or concentration of surface
runoffwill not result from this installation.
® W£LL J ~ ~
LL7T 3
(~ PE£C
TN~~2
~6W~/PE£C
TN ~
I
~,
LOT 8
LOT 4
VACANT
SO 100 ISO
SCAL~q' i' = 100
TOBBEN SPURKLAND P.E. II
203 W 15TH, AVENUE
II
ANCH. AK. 99501
SOUTH FORK LOT 3 BLOCK 6
V/EST RIVER DRIVE
EX/STING IMPROVEMENTS
I I SEPTIC SYSTEM DESIGN
DATE: JULY 17, 1996
SHEET: I/$ GRID:
25
150
iN SPURKLAND
NO, CE 2225
TOBBEN SPURKLAND P.E.
II
20,3 W 15TH. AVENUE
ANCH. AK. 99501
(907'1 279--3916
LOT 3 BLOCK 6 SOUTH FORK ~/EST
PROPOSED IMPROVEM£NI'$
PAUL WEISNER
SEPTIC SYSTEM DESIGN
DATE: JUNE 1~ 1998
SHEET: 2/3 GRID:SW 1059
SW9800XX P/D 078-051-12 SFKO60$2. DWO
~ £T
INFIL TRA TONS
5- ZlDE TRENCH
1-1/,1" PVB Schedule
Hol~s @ 18"
1250 STEP
J ,vt. of Cover
Founc/olion Cleon out
-I~" Disfibufion Pipe
Mirafi 140
INFIL TRA TONS
TOBBEN SPURKLAND P.£
205 W 15TH. AVENUE
~gNCH Ak 99501
O~ 279-791~
LO[ ~ BLOCK 6 SOUTH FORK WEST
PROPOSED CONSTRUCtiO~ SCHEMAtiC
J J SEPTIC SYSTEM DESIGN
DATE: JUNE 15, 1998
SHEEh 5/5 GRID: SWI059
SW9800XX PID 078-031-12 SFKO6055. DWG
,~ ~¢- Invert 7' -~,~
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
PERFORMED FOR:
1
2
3
4
5
8,
DATE PERFORME~
Township, Range, Section:
10 - WAS GROUND WATER
ENCOUNTERED?
11
IF YES, AT WHAT
DEPTH?
Del)ih Io Water Aller
13 - Monitoring? Date:
14-
15-
16-
17-
18-
19-
20-
SLOPE
SITE PLAN
Reading Date Gross Net Depth to Net
Time Time Water Drop
~- q~,' ~ ~ ?/~ ~-/~
PERCOLATION RATE / ~ (minutes/inch) PERC HOLE DIAMETER
P[CRFORMED BY: ~r~ ~'-~ i ~ ~' _ CERTIFY THAT THIS TEST WAS PERFORMED iN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUiDELiNES iN EFFECT ON THiS DA-~L DATE: ~'~ ~'¢~t (
72-008 (Rev. 4/85)
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502~0650
SOILS LOG -- PERCOLATION TEST
PERFORMED FOR; "~A[,~ ~..
LEGAL DESCRIPTION:
4-
5
6
7
8
g
10
11
12
13
14-
15
16
18
COMMENTS
LOT 5,
DATE FEREORME
Township, Range, Section:
SLOPE SITE PLAN
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT I (~
DEPTH? I 0 .
E
Monitoring? ' ' ~ 0ale: [/ ~,~
Reading Date Gross Net Depth to Net
Time Time Water Drop
PERCOLATION RATE / q~ ~*
(minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN FT AND ~ FT
PERFORMED BY: I,~ ' ~" "~) CERTIFY THAT THiS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES iN EFFECT ON THIS DATE. DATE:
/
72-008 (Rev. 4/85)
Rick Mystrom,
Mayor
Department of Health and Human Services
825 "L" Street
P,O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
August 28, 1997
Paul C Weisner
Sharon Buckley
PO Box 772752
Eagle River, Alaska
99577 2752
Subject: Lot 3 Block 6 Southfork West Subdivision
Permit #SW960272, PID #078-031-12
The subject permit, issued August 28, 1996 by this office for a
single family well and/or on-site wastewater system, has
expired as of August 28, 1997.
A new permit must be obtained from this office for a well
and/or on-site wastewater system NOT installed by the
expiration date.
If you have drilled the well, a well log must be sent to
this office for documentation of the installation and to
close the permit.
If a licensed Professional Engineer has inspected the
installation of the on-site wastewater system, the original
as-built inspection report must be sent to this office for
review, approval and documentation. Ail inspection reports
must be submitted within 30 days of construction completion.
When applying for a new permit, the fees are: $320.00 fo~ an
on-site wastewater permit; $120.00 for a well permit and
$440.00'for a combined on-site wastewater and well permit.
If you have any questions, please call this office at 343-4744.
SiCerely, ~f
J~ames Cross, P.E.
Program Manager
On-site Services
enc: Copy of Permit
cc: Tobben Spurkland, P.E.
PAGE
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT
PERMIT ATUMBER:SW960272
DESIGN ENGINEER:TOBBEN SPURKLAND, P.E.
OWNER NAME:WEISNER PAUL C 50% &
OWNER ADDRESS:P.O. BOX 772752
EAGLE RIVER, ALASKA 99577
DATE ISSUED: 8/28/96
EXPIRATION DATE:
PARCEL ID:07803112
LEGAL DESCRIPTION:
SOUTHFORK WEST BLK
6 LT 3
LOT SIZE: 149684 (SQ. FT.)
NUMBER OF BEDROOMS: 3 THIS PERMIT: 3
THIS PERMIT IS FOR THE CONSTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAACS0) .
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
i OF
8/28/97
SPECIAL PROVISIONS: /""
RECEIVED BY: ~~
ISSUED BY: ~ ~ ~~
T.SPURKLAND P.E.
203 W. 15th. AVE. SUITE 203 '
ANCHORAGE, ALASKA 99501
(907) 279-3916
Fax (907)-276-6013
RECEIVED
James Cross P.E.
Municipality of Anchorage
Department of Health and Social Services
820 1 Street
Anchorage, Alaska 99501
S ubj e ct:
SW960272
Southfork West Blk 6, Lot 3
Weisner Paul
April 15, 1997
Gentlemen;
My client would like to install Infiltrators in the proposed drainfield for his lot. Cost and less
damage to the lot by construction equipment are the main reasons for this request. I have enclosed
a revised drawing 3 of 3 that shows this proposed substitution. Please review and comment.
Yours
203 W 15th. Avenue, Suite 203
ANCHORAGE, ALASKA 99501
(907) 279-3916
Fax (907)-276-6013
SEPTIC SYSTEM DESIGN
LOT 3 BLOCK 6 SOUTH FORK WEST
PAUL WEISNER
RECEIVED
APR ? lag?
Municipality of Anchorage
Dept, Health & Human Services
Municipality of Anchorage
Department of Health and Social Services
820 1 Street
Anchomge, Alaska 99501
April 16, 1997
We are submitting an application for the installation of a well and septic system for this lot. The
submittal consist of three (3) drawings showing the present improvements on the lot and the
adjoining properties, (sheet 1/3), the proposed improvements of the lot, of which only the well
and septic system are subject to this permit application, (sheet 2/3), and a schematic of the septic
system, (sheet 3/3). Soil logs and percolation tests of applicable testholes are also enclosed.
The septic system design is based on the following:
Ground Water at 5 ft.
Use BioCycle
Use 3-foot WIDE TRENCH WITH INFILTRATORS
Soil Rating. 10 min/in - 1.6 gal per sq.ft/day
No. of Bedrooms 3
Required Area per Bedroom: 150/1.6 =93.75 sq.ft..
Total area required: 93.75 x 3 = 281.25 sq ft
Length of Trench: 281.25 / 3 = 94.0 ft
SYSTEM CONFIGURATION
BIOCYCLE
3-FOOT WIDE
TOTAL LENGTH 94 FT
TOTAL WIDTH 3 FT
TOTAL DEPTH 1 FT
ROCK DEPTH NONE
COVER 3 FT
The installation of this septic system will not prevent wells from be installed on the adjacent lots.
~ttere are no developed or natural surface / sub surface drainage courses on this or the adjacent lots.
The proposed septic system will not change the general slope of the ama. Ponding and/or concentration of surface
runoff will not result from this installation.
N
\
\
SPURKLAND
% CE-2225
TOBBEN SPURKLAND P.E. I
205 W 15TH, AVENUE
I
ANCH. AK. 99501
LOT 3 BLOCK 6 SOUTH FORK WEST
PROPOSED IMPROVEMENTS
PAUL Y/EISNER
SEPTIC SYSTEM DESIGN
DATE: JULY 14 1996
SHEET: 2/$ GRID:S~ 1059
Il
9,/ FT
1-I/4" PVC Schedule
5~/16'' Holes @
3- WIDE TRENCH
5 Ff. of Cover
SAND BACKFILL
Myers Pump ME40 4/10 NP
1-i/4" Oisfibufion Pipe
M/raft 140
d-INCH INSULATION
AIRCOMPRESSOR
LEGEND:
2.
3.
4.
5.
BIOCYCLE 6000
INFILTRATORS
REVISED: APRIL 15, i997
ADDED INFILTRATORS
DELETED SEWER ROCK
PRIMARY TREATMENT, ,~E~TIC TANK
AERATION TANK , :
CLARIFICATION TANK
DISCHARGE TANK !
SOIL ABSORPTION :" '"
BENCH MARK:
TOBBEN SPURKLAND P.E.
203 W iSTH. AVENUE
IANCH AK 99501
(90~I 2Y~-sgI~
SW960272
II BIOC¥CLE AERAT£D TREATMENT PLANT
LOT 5, BLOCK 6 SOUTH FORK WEST
PROPOSED CONSTRUCTION, SCHEMATIC
II SEPTIC SYSTEM DESIGN
DATE: JULY i7, i996
SHEET: 3/5 GRID: SWi059
P/D 078-051-12 SFKO6055. DWG
203 W 15th. Avenue, Suite 203
ANCHORAGE, ALASKA 99501
(907) 279-3916
Fax (907)-276-6013
SEPTIC SYSTEM DESIGN
LOT 3 BLOCK 6 SOUTH FORK WEST
PAUL WEISNER
Municipality of Anchorage
Department of Health and Social Services
820 1 Street
Anchorage, Alaska 99501
July 17, 1996
We are submitting an application for the installation of a well and septic system for this lot. The
submittal consist of three (3) drawings showing the present improvements on the lot and the
adjoining properties, (sheet 1/3), the proposed improvements of the lot, of which only the well
and septic system are subject to this permit application, (sheet 2/3), and a schematic of the septic
system, (sheet 3/3). Soil logs and percolation tests of applicable testholes are also enclosed.
The septic system design is based on the following:
Ground Water at 5 fi.
Use BioCyele
Use Standard 5 Wide Trench
Soil Rating. 10 rain/in - 1.6 gal per sq.fffday
No. of Bedrooms 3
Required Area per Bedroom: 150/1.6=93.75 sq.fi..
Total area required: 93.75 x 3 = 281.25 sq ft
Length of Trench: 281.25 / 5 = 56.25 If.
SYSTEM CONFIGURATION
BIOCYCLE
STANDARD 5 WIDE TRENCH
TOTAL LENGTH 57 FT
TOTAL WIDTH 5 FT
TOTAL DEPTH I FT
ROCK DEPTH .5 FT
COVER 3 FT
The installation of this septic system will not prevent wells from be installed on the adjacent lots.
There are no developed or natural surface / sub surface drainage courses on this or the adjacent lots.
The proposed septic system will not change the general slope of the area. Ponding and/or concentration of surface
runoff will not result from this installation.
WELL
£EP TI~~-
LOT $
I ,,, SCAL~C' ]'" = ZOO FL
TOBBEN SPURKLAND P.E.
205 W 15TH. AVENUE
ANCH. AK. 99501
SOUTH FORK LOT 3 BLOCK 6 11 SEPTIC SYSTEM DESIGN
V/EST RIVER DRIVE [[ DATE: JULY 17,1996
EXIST/NO IMPf~OVEMENTS SHEET: I/$ GRID:
25
150
No, CE 2225
TOBBEN SPURKLAND P.E.
20,3 W 15TH. AVENUE
ANCH. AK. 99501
LOT 3 BLOCK 6 SOUTH FORK ~FEST
PROPOSED IMPROVEMENTS
PAUL WEISNER
SEPTIC SYSTEM DESIGN
DATE: JULY 17, 1996
SHEET: 2/5 GRID:SW 1059
57 FT
~- 1-1/4" PVC Schedule
$/16" Holes ~ I$"
5- ~flDE TRENCH
5 Ft. of Cover
6" Sewer Rock
1-1/4" Oistibufton Pipe
M/raft 140
BIOCYCLE PLANT
Myers Pump ME404/IOHP
BENCH~IARKL:
TOBBEN SPURKLAND P.E.
205 W 15TN, AVENUE
~gNCH AK. 99501
07)' 279-5916
BIOCYC£E AERATED TREATMENT PLANT
LOT $, BLOCK 6 SOUTH FORK WEST
PROPOSED CONSTRUCTION, SCHEMATIC
J J SEPTIC SYSTEM DESIGN
DATE: JULY 17, 1996
SHEET: 5/5 GRID: SW1059
FOR THE MAINTENANCE OF AN
ON-SITE WASTEWATER DISPOSAL
SYSTEM
This agreement, dated ,7'0 J.y' ~ 199.~.~, is made between the Municipality of
Anchgrage Departg]~nt of Health ~d Human Services (DHHS) and tho.property owner(s)
of: ~o~3 y ~/ocA
This agreement is made for the purpose of maintaining an on-site wastewater disposal
system on the subject property.
The property owners agree to the following:
Allow the Municipality of Anchorage the perpetual right of entry to the property during
normal working hours, to allow for effluent sampling or evaluating the general state of
repair or function of the system.
Submit to the Municipality of Anchorage, on an annual basis, an inspection and operation
statement from a registered professional engineer. This inspection and Operation
statement shall verify that file engineer has inspected all effluent and air pumps, timers, and
alarms, and that any deficiencies have been repaired and that the system is functioning as
designed.
[Signature)
(Pfinmd Name)
(Signature)
(Printed Name)
My Commission E. xplres
March 4, 2000
(Notarize Here)
Rick Mystrom,
Mayor
Municipality of Anchorage
Department of Health and Human Services
825 "L" Street
P.O. Box 196650 Anchorage, Alaska 99519-6650
Dear Ho~neowner/Prospective Buyer:
The on-site wastewater disposal you are interested in purchasing is m "altemative" wastewater disposal
system. This system, known as a "Biocycle Aerated Wastewater Treatment System", is undergoing testing
within the Mm~icipality of Anchorage under the Alternative System section of the Wastewater Disposal
Regulations (AMC 15.65). Tliere are certain risks involved with the ownership of one of these systems:
This system has been shown to be effective in other areas. The system is currendy undergoing a
two year testing period in Anchorage under the guidance of the Department of Health and Human
Services (DHHS) and rite State of Alaska Department of Environmental Conservation (ADEC) to
determine its effectiveness in a subamtic environment. Testing results on systems installed in 1994
have been very encouraging. Copies of initial test results are available from the DHHS.
The Biocycle system has ]lot been tested and approved by tile National Sanitation Foundation
(NSF). Currently, Anchorage Municipal Code for Wastewater Disposal Regulations requires
proprietary equipment to have NSF approval. This approval or changes to tile Wastewater
Disposal Regulations through Municipal Assembly action will be necessary prior to this system
being approved as a standard system.
The "Biocycle" system for this property may have received vertical separation distance waivers
from both State of Alaska and Anchorage Municipal Codes to both ground water and bedrock.
These waivers were granted due to the system's expected performance within the site conditions on
this property. If the test results do not support these waivers, modification or replacement of this
system may be required.
If this system falls to meet the requirements set for it to become a standard, code approved
wastewater disposal system, it may have to be removed and replaced by either a holding tank or (if
possible) other wasfewater disposal system that meets Municipality of Anchorage requirements.
The cost of any conversions required to meet code requirements will be the responsibility of the
homeowner at the time of conversion.
I (we) certify that I (we) have read the above statements and am (are) aware of the risks outlined. I (we)
also certify thai I (we) am (are) in the process of. purchasing (propertT,legal description):
(Purohaser Name)
(Purchaser Signature)
~ Commi~on
M~4,~
-*x~. arch~er N%me)
(Purchaser Signature)