Loading...
HomeMy WebLinkAboutSOUTHFORK WEST BLK 6 LT 3 Rick Mystrom. Mayor Municipality of Anchorage Department of Health and Human Services 825 "u' Street P.O, Box 196650 Anchorage. Alaska 99519-6650 http://www.ci.anchorage.ak.us July 8, 1999 Michael & Karen Boylan PO BOX 241283 Anchorage, AK 995241283 Subject: SOUTHFORK WEST BLK 6 LT 3 Permit # SW980235 PID # 078-031-12 The subject permit, issued 7/15/98 by tNs office for a single family well and/or on-site wastewater system, is due to expire as of 7/15/99. If you have drilled the well, a well log must be sent to this office for documentation of the installation and to close the permit. Ifa licensed Professional Engineer has inspected the installation of the on-site wastewater system, the original as-built inspection report must be sent to this office for review, approval and documentation. All inspection reports must be submitted witNn 30 days of construction completion. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. However a new permit can be issued free of charge for a second year if the application for the renewal is received on or before the date of expiration of the original permit for wNch a fee was paid. When applying for a new permit after the original permit has expired or for more than a second year, the fees are: $320.00 for an on-site wastewater permit and $120.00 for a well permit. If you have any questions, please call this office at 343-4744. Program Manager On-site Services enc: Copy of Permit MUNICIPALITY OF ANCHORAGE Depatfment of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.O, Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Date Issued: Jul 15, 1998 Expiration Date: Jul 15, 1999 Permit Number: SW980235 Legal Description: SOUTHFORK WEST BLK 6 LT 3 Design Engineer: Tobben Spurkland, P.E. Owner Name: PAUL C. WEISNER Owner Address: PO BOX 772752 EAGLE RIVER, AK 99577-2752 ParcellD: 078-031-12 Site Address: Lot Size: 149684 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: [] Disposal Field [] SepticTank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343~4744( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date: 7 -',~'~ ~~' Date: 203 W 15th. Avenue, Suite 203 ANCHORAGE, ALASKA 99501 (907) 279-3916 Fax (907)-276-6013 SEPTIC SYSTEM DESIGN LOT 3 BLOCK 6 SOUTH FORK WEST PAUL WEISNER Municipality of Anchorage Department of Health and Social Services 820 1 Street Anchorage, Alaska 99501 June 12, 1998 We are submitting an application for the installation of a well and septic system for this lot. The submittal consist of three (3) drawings showing the present improvements on the lot and the adjoining properties, (sheet 1/3), the proposed improvements of the lot, of which only the well and septic system are subject to this permit application, (sheet 2/3), and a schematic of the septic system, (sheet 3/3). Soil logs and percolation tests of applicable testholes are also enclosed. The septic system design is based on the following: Ground Water at 5 ff. Use 1250 STEP Use 5-foot WIDE TRENCH WITH INFILTRATORS Soil Rating. 10 mhKin = 1.6 gal per sq.fl/day No. of Bedrooms 3 Required Area per Bedroom: 150/0.8 - 187.5 sq.ff.. Total area required: I87.5 x 3 = 562.5 sq ft Length of Trench: 562.5 /5 -- 112.5 ft SYSTEM CONFIGURATION 1250 STEP 5-FOOT WIDE TOTAL LENGTH 2 x 60 - 120 FT TOTAL WIDTH 5 FT TOTAL DEPTH I FT ROCK DEPTH NONE COVER 3 FT The installation of this septic system will not prevent wells from be installed on the adjacent lots. There are no developed or natural surface / sub surface drainage courses on this or the ad.~acent lots. The proposed septic system will not change the general slope of the area. Ponding and/or concentration of surface runoffwill not result from this installation. ® W£LL J ~ ~ LL7T 3 (~ PE£C TN~~2 ~6W~/PE£C TN ~ I ~, LOT 8 LOT 4 VACANT SO 100 ISO SCAL~q' i' = 100 TOBBEN SPURKLAND P.E. II 203 W 15TH, AVENUE II ANCH. AK. 99501 SOUTH FORK LOT 3 BLOCK 6 V/EST RIVER DRIVE EX/STING IMPROVEMENTS I I SEPTIC SYSTEM DESIGN DATE: JULY 17, 1996 SHEET: I/$ GRID: 25 150 iN SPURKLAND NO, CE 2225 TOBBEN SPURKLAND P.E. II 20,3 W 15TH. AVENUE ANCH. AK. 99501 (907'1 279--3916 LOT 3 BLOCK 6 SOUTH FORK ~/EST PROPOSED IMPROVEM£NI'$ PAUL WEISNER SEPTIC SYSTEM DESIGN DATE: JUNE 1~ 1998 SHEET: 2/3 GRID:SW 1059 SW9800XX P/D 078-051-12 SFKO60$2. DWO ~ £T INFIL TRA TONS 5- ZlDE TRENCH 1-1/,1" PVB Schedule Hol~s @ 18" 1250 STEP J ,vt. of Cover Founc/olion Cleon out -I~" Disfibufion Pipe Mirafi 140 INFIL TRA TONS TOBBEN SPURKLAND P.£ 205 W 15TH. AVENUE ~gNCH Ak 99501 O~ 279-791~ LO[ ~ BLOCK 6 SOUTH FORK WEST PROPOSED CONSTRUCtiO~ SCHEMAtiC J J SEPTIC SYSTEM DESIGN DATE: JUNE 15, 1998 SHEEh 5/5 GRID: SWI059 SW9800XX PID 078-031-12 SFKO6055. DWG ,~ ~¢- Invert 7' -~,~ Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: 1 2 3 4 5 8, DATE PERFORME~ Township, Range, Section: 10 - WAS GROUND WATER ENCOUNTERED? 11 IF YES, AT WHAT DEPTH? Del)ih Io Water Aller 13 - Monitoring? Date: 14- 15- 16- 17- 18- 19- 20- SLOPE SITE PLAN Reading Date Gross Net Depth to Net Time Time Water Drop ~- q~,' ~ ~ ?/~ ~-/~ PERCOLATION RATE / ~ (minutes/inch) PERC HOLE DIAMETER P[CRFORMED BY: ~r~ ~'-~ i ~ ~' _ CERTIFY THAT THIS TEST WAS PERFORMED iN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUiDELiNES iN EFFECT ON THiS DA-~L DATE: ~'~ ~'¢~t ( 72-008 (Rev. 4/85) Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502~0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR; "~A[,~ ~.. LEGAL DESCRIPTION: 4- 5 6 7 8 g 10 11 12 13 14- 15 16 18 COMMENTS LOT 5, DATE FEREORME Township, Range, Section: SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT I (~ DEPTH? I 0 . E Monitoring? ' ' ~ 0ale: [/ ~,~ Reading Date Gross Net Depth to Net Time Time Water Drop PERCOLATION RATE / q~ ~* (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN FT AND ~ FT PERFORMED BY: I,~ ' ~" "~) CERTIFY THAT THiS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES iN EFFECT ON THIS DATE. DATE: / 72-008 (Rev. 4/85) Rick Mystrom, Mayor Department of Health and Human Services 825 "L" Street P,O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 August 28, 1997 Paul C Weisner Sharon Buckley PO Box 772752 Eagle River, Alaska 99577 2752 Subject: Lot 3 Block 6 Southfork West Subdivision Permit #SW960272, PID #078-031-12 The subject permit, issued August 28, 1996 by this office for a single family well and/or on-site wastewater system, has expired as of August 28, 1997. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. If you have drilled the well, a well log must be sent to this office for documentation of the installation and to close the permit. If a licensed Professional Engineer has inspected the installation of the on-site wastewater system, the original as-built inspection report must be sent to this office for review, approval and documentation. Ail inspection reports must be submitted within 30 days of construction completion. When applying for a new permit, the fees are: $320.00 fo~ an on-site wastewater permit; $120.00 for a well permit and $440.00'for a combined on-site wastewater and well permit. If you have any questions, please call this office at 343-4744. SiCerely, ~f J~ames Cross, P.E. Program Manager On-site Services enc: Copy of Permit cc: Tobben Spurkland, P.E. PAGE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT ATUMBER:SW960272 DESIGN ENGINEER:TOBBEN SPURKLAND, P.E. OWNER NAME:WEISNER PAUL C 50% & OWNER ADDRESS:P.O. BOX 772752 EAGLE RIVER, ALASKA 99577 DATE ISSUED: 8/28/96 EXPIRATION DATE: PARCEL ID:07803112 LEGAL DESCRIPTION: SOUTHFORK WEST BLK 6 LT 3 LOT SIZE: 149684 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAACS0) . 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. i OF 8/28/97 SPECIAL PROVISIONS: /"" RECEIVED BY: ~~ ISSUED BY: ~ ~ ~~ T.SPURKLAND P.E. 203 W. 15th. AVE. SUITE 203 ' ANCHORAGE, ALASKA 99501 (907) 279-3916 Fax (907)-276-6013 RECEIVED James Cross P.E. Municipality of Anchorage Department of Health and Social Services 820 1 Street Anchorage, Alaska 99501 S ubj e ct: SW960272 Southfork West Blk 6, Lot 3 Weisner Paul April 15, 1997 Gentlemen; My client would like to install Infiltrators in the proposed drainfield for his lot. Cost and less damage to the lot by construction equipment are the main reasons for this request. I have enclosed a revised drawing 3 of 3 that shows this proposed substitution. Please review and comment. Yours 203 W 15th. Avenue, Suite 203 ANCHORAGE, ALASKA 99501 (907) 279-3916 Fax (907)-276-6013 SEPTIC SYSTEM DESIGN LOT 3 BLOCK 6 SOUTH FORK WEST PAUL WEISNER RECEIVED APR ? lag? Municipality of Anchorage Dept, Health & Human Services Municipality of Anchorage Department of Health and Social Services 820 1 Street Anchomge, Alaska 99501 April 16, 1997 We are submitting an application for the installation of a well and septic system for this lot. The submittal consist of three (3) drawings showing the present improvements on the lot and the adjoining properties, (sheet 1/3), the proposed improvements of the lot, of which only the well and septic system are subject to this permit application, (sheet 2/3), and a schematic of the septic system, (sheet 3/3). Soil logs and percolation tests of applicable testholes are also enclosed. The septic system design is based on the following: Ground Water at 5 ft. Use BioCycle Use 3-foot WIDE TRENCH WITH INFILTRATORS Soil Rating. 10 min/in - 1.6 gal per sq.ft/day No. of Bedrooms 3 Required Area per Bedroom: 150/1.6 =93.75 sq.ft.. Total area required: 93.75 x 3 = 281.25 sq ft Length of Trench: 281.25 / 3 = 94.0 ft SYSTEM CONFIGURATION BIOCYCLE 3-FOOT WIDE TOTAL LENGTH 94 FT TOTAL WIDTH 3 FT TOTAL DEPTH 1 FT ROCK DEPTH NONE COVER 3 FT The installation of this septic system will not prevent wells from be installed on the adjacent lots. ~ttere are no developed or natural surface / sub surface drainage courses on this or the adjacent lots. The proposed septic system will not change the general slope of the ama. Ponding and/or concentration of surface runoff will not result from this installation. N \ \ SPURKLAND % CE-2225 TOBBEN SPURKLAND P.E. I 205 W 15TH, AVENUE I ANCH. AK. 99501 LOT 3 BLOCK 6 SOUTH FORK WEST PROPOSED IMPROVEMENTS PAUL Y/EISNER SEPTIC SYSTEM DESIGN DATE: JULY 14 1996 SHEET: 2/$ GRID:S~ 1059 Il 9,/ FT 1-I/4" PVC Schedule 5~/16'' Holes @ 3- WIDE TRENCH 5 Ff. of Cover SAND BACKFILL Myers Pump ME40 4/10 NP 1-i/4" Oisfibufion Pipe M/raft 140 d-INCH INSULATION AIRCOMPRESSOR LEGEND: 2. 3. 4. 5. BIOCYCLE 6000 INFILTRATORS REVISED: APRIL 15, i997 ADDED INFILTRATORS DELETED SEWER ROCK PRIMARY TREATMENT, ,~E~TIC TANK AERATION TANK , : CLARIFICATION TANK DISCHARGE TANK ! SOIL ABSORPTION :" '" BENCH MARK: TOBBEN SPURKLAND P.E. 203 W iSTH. AVENUE IANCH AK 99501 (90~I 2Y~-sgI~ SW960272 II BIOC¥CLE AERAT£D TREATMENT PLANT LOT 5, BLOCK 6 SOUTH FORK WEST PROPOSED CONSTRUCTION, SCHEMATIC II SEPTIC SYSTEM DESIGN DATE: JULY i7, i996 SHEET: 3/5 GRID: SWi059 P/D 078-051-12 SFKO6055. DWG 203 W 15th. Avenue, Suite 203 ANCHORAGE, ALASKA 99501 (907) 279-3916 Fax (907)-276-6013 SEPTIC SYSTEM DESIGN LOT 3 BLOCK 6 SOUTH FORK WEST PAUL WEISNER Municipality of Anchorage Department of Health and Social Services 820 1 Street Anchorage, Alaska 99501 July 17, 1996 We are submitting an application for the installation of a well and septic system for this lot. The submittal consist of three (3) drawings showing the present improvements on the lot and the adjoining properties, (sheet 1/3), the proposed improvements of the lot, of which only the well and septic system are subject to this permit application, (sheet 2/3), and a schematic of the septic system, (sheet 3/3). Soil logs and percolation tests of applicable testholes are also enclosed. The septic system design is based on the following: Ground Water at 5 fi. Use BioCyele Use Standard 5 Wide Trench Soil Rating. 10 rain/in - 1.6 gal per sq.fffday No. of Bedrooms 3 Required Area per Bedroom: 150/1.6=93.75 sq.fi.. Total area required: 93.75 x 3 = 281.25 sq ft Length of Trench: 281.25 / 5 = 56.25 If. SYSTEM CONFIGURATION BIOCYCLE STANDARD 5 WIDE TRENCH TOTAL LENGTH 57 FT TOTAL WIDTH 5 FT TOTAL DEPTH I FT ROCK DEPTH .5 FT COVER 3 FT The installation of this septic system will not prevent wells from be installed on the adjacent lots. There are no developed or natural surface / sub surface drainage courses on this or the adjacent lots. The proposed septic system will not change the general slope of the area. Ponding and/or concentration of surface runoff will not result from this installation. WELL £EP TI~~- LOT $ I ,,, SCAL~C' ]'" = ZOO FL TOBBEN SPURKLAND P.E. 205 W 15TH. AVENUE ANCH. AK. 99501 SOUTH FORK LOT 3 BLOCK 6 11 SEPTIC SYSTEM DESIGN V/EST RIVER DRIVE [[ DATE: JULY 17,1996 EXIST/NO IMPf~OVEMENTS SHEET: I/$ GRID: 25 150 No, CE 2225 TOBBEN SPURKLAND P.E. 20,3 W 15TH. AVENUE ANCH. AK. 99501 LOT 3 BLOCK 6 SOUTH FORK ~FEST PROPOSED IMPROVEMENTS PAUL WEISNER SEPTIC SYSTEM DESIGN DATE: JULY 17, 1996 SHEET: 2/5 GRID:SW 1059 57 FT ~- 1-1/4" PVC Schedule $/16" Holes ~ I$" 5- ~flDE TRENCH 5 Ft. of Cover 6" Sewer Rock 1-1/4" Oistibufton Pipe M/raft 140 BIOCYCLE PLANT Myers Pump ME404/IOHP BENCH~IARKL: TOBBEN SPURKLAND P.E. 205 W 15TN, AVENUE ~gNCH AK. 99501 07)' 279-5916 BIOCYC£E AERATED TREATMENT PLANT LOT $, BLOCK 6 SOUTH FORK WEST PROPOSED CONSTRUCTION, SCHEMATIC J J SEPTIC SYSTEM DESIGN DATE: JULY 17, 1996 SHEET: 5/5 GRID: SW1059 FOR THE MAINTENANCE OF AN ON-SITE WASTEWATER DISPOSAL SYSTEM This agreement, dated ,7'0 J.y' ~ 199.~.~, is made between the Municipality of Anchgrage Departg]~nt of Health ~d Human Services (DHHS) and tho.property owner(s) of: ~o~3 y ~/ocA This agreement is made for the purpose of maintaining an on-site wastewater disposal system on the subject property. The property owners agree to the following: Allow the Municipality of Anchorage the perpetual right of entry to the property during normal working hours, to allow for effluent sampling or evaluating the general state of repair or function of the system. Submit to the Municipality of Anchorage, on an annual basis, an inspection and operation statement from a registered professional engineer. This inspection and Operation statement shall verify that file engineer has inspected all effluent and air pumps, timers, and alarms, and that any deficiencies have been repaired and that the system is functioning as designed. [Signature) (Pfinmd Name) (Signature) (Printed Name) My Commission E. xplres March 4, 2000 (Notarize Here) Rick Mystrom, Mayor Municipality of Anchorage Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 Dear Ho~neowner/Prospective Buyer: The on-site wastewater disposal you are interested in purchasing is m "altemative" wastewater disposal system. This system, known as a "Biocycle Aerated Wastewater Treatment System", is undergoing testing within the Mm~icipality of Anchorage under the Alternative System section of the Wastewater Disposal Regulations (AMC 15.65). Tliere are certain risks involved with the ownership of one of these systems: This system has been shown to be effective in other areas. The system is currendy undergoing a two year testing period in Anchorage under the guidance of the Department of Health and Human Services (DHHS) and rite State of Alaska Department of Environmental Conservation (ADEC) to determine its effectiveness in a subamtic environment. Testing results on systems installed in 1994 have been very encouraging. Copies of initial test results are available from the DHHS. The Biocycle system has ]lot been tested and approved by tile National Sanitation Foundation (NSF). Currently, Anchorage Municipal Code for Wastewater Disposal Regulations requires proprietary equipment to have NSF approval. This approval or changes to tile Wastewater Disposal Regulations through Municipal Assembly action will be necessary prior to this system being approved as a standard system. The "Biocycle" system for this property may have received vertical separation distance waivers from both State of Alaska and Anchorage Municipal Codes to both ground water and bedrock. These waivers were granted due to the system's expected performance within the site conditions on this property. If the test results do not support these waivers, modification or replacement of this system may be required. If this system falls to meet the requirements set for it to become a standard, code approved wastewater disposal system, it may have to be removed and replaced by either a holding tank or (if possible) other wasfewater disposal system that meets Municipality of Anchorage requirements. The cost of any conversions required to meet code requirements will be the responsibility of the homeowner at the time of conversion. I (we) certify that I (we) have read the above statements and am (are) aware of the risks outlined. I (we) also certify thai I (we) am (are) in the process of. purchasing (propertT,legal description): (Purohaser Name) (Purchaser Signature) ~ Commi~on M~4,~ -*x~. arch~er N%me) (Purchaser Signature)