HomeMy WebLinkAboutSPENDLOVE VIEW HEIGHTS BLK 3 LT 6P ndlove View Height lock Lot 6 021-021 -14 Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program, 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www.ci.anchorage.ak.us (907) 343-7904 Page of ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: sw950328 PID Number: 021-021-14 Name: Albert and Valerie Young Wastewater System: [] New [] Upgrade Address: P.O. Box 112071 Anchorage, AK 99511 ABSORPTION FIELD Phone: Number of Bedrooms: 5 ~' Deep Trench [] Shallow Trench [] Bed [] Mound [] Other: Soil Rating: Total Depth from odginal grade: LEGAL DESCRIPTION 1.2 GPD/Ft2 12-13 Ft. il', Lot: / Subdivision: Depth to pipe bottom from onginal grade: Gravel depth beneath pipe: '-2 Lc Spendlove View 6-7 6 ~ Ft. Ft Township: Range: Section: Fill added above original grade:Gravel Length: 2-3 Ft. 60 Ft, Well: [] New [] Upgrade Classification (Private, A, B, C): Total Depth: I Cased to: Private 386 Ft. Static VVst23er Level: Ft Ddller: Date Drilled: Alpine Drilling 7/3/96 21 Ft Yield: GPM Pump Set at: Casing Height Above Ground: 2 Ft. 2 Ft. SEPARATION DISTANCES ~ To I Septic I Absorption From '~ Tank Field Well I >100' >100' Surface Water I >100' >100' LotL~ r >5' >10' Foundation I >5' >10' C~ain Ora~n I None t Noted Remarks: Lift Station Holding Tank N/A N/A N/A N/A N/A N/A N/A N/A ~ublic/Private l Sewer Line I >25' Gravel width: 3 Total absorption area: 72O Installer: Harten Construction Ft. Ft2 Number of lines: Distance between lines: I - Ft. Pipe Matedal: ASTM D3034 PVC Date Installed: 6/96 TANK [] Septic [] Holding [] S.T.E.P. Manufacturer: Anchorage Tank Material: Steel Size: "Pump on" level at: LIFT STATION IManufacturer: OllI "Pump off" level at: in. Electrical Inspections performed by: Pump Make & Model [] Other: Capacity: 1,500 Gal. Number of Compartments: Two (2) High water alarm at: in. Installation Verified by Anderson Engineering. Original BENCH MARK Location and Description: Installation Inspected by James Sizemore, P.E. Door Threshold Near Foundation Clean Out. Assumed Elevation: Septic System Meets Municipal Code. 100.0 Ft Inspections performed by: J. Sizemore Dates: 1st 6/96 2nd 6/96 Development Services Department Approval Conditional Approval Date: ~/,~, ,, / ~f~?Date: /"'/"2 ~-'// ~e?v~i4~ed and approved by: ~ Permit Number: SW960145 Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 Page 2 of 3 PID No. 021-021-14 N 90°00'00"E 281.91' / / / / / / WE~ GRAVEL DRI oo~%¢~ RETAINING WALL S1 C4 28,6' 16.2' C5 38.2' NOTE: (~) 3~.--~ S1 Existing Septic System Constructed in 1996 by James HaMcen Construction and Inspected by Jim Sizemore, P.E. SPENDLOVE VIEW HEIGHTS ~ I VOLLEYBALL LOT 6, BLOCK 3 LEGEND: ~ COURT S2 CO - Cleanout SV - Septic Vent TH - Test Hole MT - Monitor Tube FCO - Foundation Clean Out PLAN AS-BUILT SCALE 1' = 40' Permit Number: SW960145 Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 On-Site Wastewater Disposal System or Well ~nspection Report Page 3 of 3 PID No. 021-021-14 Finished //91.95j SepticTank [ 9~1.75/ 95.0 96.6 O~nai-Gra~ Geotextile Fabdc 88.0- --~ Drainfieid Rock 82.0 97.0 88.0 60' (Trench Length) EXISTING TRENCH NOTE: Existing Septic System Constructed in 1996 by Harten Construction and Inspected by Jim Sizemore, P.E. PROFILE AS-BUILT No Scale A700 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT BRAGAW STREET ANCHORAGE, AK c)951c)-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: PERFORMED FOR: ALBERT YOUNG DATE: &/25/2011 PROJECT No.: PARCEL ID#: TECHNICL&N: DEPTH TEST HOLE A (feet) 1 OB/0G SLOPE 2 3 4 6 7 8 GRAVEL WITH SAND AND SILT 9 GW/GN/GP WAS GROUND WATER ENCOUNTERED? No ~ YES ~ WHAT DEPTH?.I DEPTH OF WATER AFTER MO~TOPdNG: NONE 11 DATE OF MO~TORrNG: &/25/Il 20-- BOH @ 20' LOT 6, BLOCK 3, SPENDLOVE VIEW SUBDIVISION A. HARALA PERCOLATION RATE: TEST RUN BETWEEN: SITE PLAN SEE SITE PLAN 2% _____--- DEPTH TO DATE READING GROSS TINE NET TINE WATER NET DROP (PIlNUTES) (PIlNUTES) (INCHES) (INCHES) __(MnW~NCH) PERC. HOLE DIA. .(FNCHES) FT. and FT. COMMENTS: TEST HOLE PLACED TO VERIFY NO BEDROCK WITHIN 6' OF BOTTOM OF TRENCH. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: Z,/25/2011 PAGE 1 OF 1 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW950328 DESIGN ENGINEER:JAMES SIZEMOORE & ASSOCIATES OWNER NAME:YOUNG ALBERT K & VALERIE J OWNER ADDRESS:P.O. BOX 112071 ANCHORAGE, AK 99511 DATE ISSUED:10/07/95 EXPIRATION DATE:10/07/96 PARCEL ID:02102114 LEGAL DESCRIPTION: SPENDLOVE VIEW HEIGHTS BLK 3 LT 6 LOT SIZE: 58601 (SQ. FT.) NUMBER OF BEDROOMS: ~THIS PERMIT: ~ ~ THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAACS0) . 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS RECEIVED BY: RECEIVED MAY 2 4 1996 Municipality of Anchorage Dept. Health & Human Services May 22, 1996 MUNICIPALITY OF ANCHORAGE DEPARTMENI' OP HEALi'H AND HUMAN SERVICES 825 ~L'? STREET, ROOM 502 ANCHORAGE, ALASKA 99519 AT'fENTION MR. DAN ROi'H: Dear Dan: Reference Permit No. ' SW950328 The owner of the property on which this proposed system is located has informed me that he intends to build a fbur bedroom house with the intention of later changing it to a five bedroom home. I informed him to install a 1500 gal septic tank and to make the drainfield large enough tbr the future 5 bedrooms. I have included a design for the five bedroom home, and changed the plans and specifications to show the five bedroom I request that the permit be modified to allow for the 5 bedroom home. Sincerely yours.~.fl/fi_e> James F. Sizemore P. E. MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 PAGE 1 OF ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW940396 DESIGN ENGINEER:JAMES SIZEMOORE & ASSOCIATES OWNER NAME:YOUNG ALBERT K & VALERIE J OWNER ADDRESS:P.O.BOX 112071 ANCHORAGE, AK 99511 DATE ISSUED:10/12/94 EXPIRATION DATE:10/12/95 PARCEL ID:02102114 LEGAL DESCRIPTION: SPENDLOVE VIEW HEIGHTS BLK LT 6 LOT SIZE: 58601 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: 4 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAACS0) . 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 (24 HOURS) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: DATE: James Sizemore & Associates 6410 Switzerland Drive /907) 345-1572 Civil Engineers & Surveyors Anchorage, AK 99516 WASTEWATER DISPOSAL SYSTEM SPECIFICATIONS LOT 6 BL3, SPENDLOVE VIEW HEIGHTS SUBDIVISION 1.0 GENERAL: 1.1 The scope of the project consists of installation of a gallon septic tank and a long by 9 ' deep, deep trench d~ainfield. 5~.£ - 1.2 Construction shall be as shown on the approved site plan and design drawings. Deviations from the drawings shall be co-ordinated and approved by the engineer conducting the inspections. 1.3 Ail construction procedures and material used to construct the system shall comply with Municipal and State regulations. 1.4 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading areas after the soil is compacted. Placement of topsoil and reseeding all areas disturbed by construction is also the responsibility of the homeowneer. 2.0 SEPTIC TANK: 2.1 The gallon septic tank shall be Municipally approved. 2.2 The septic tank shall be set level and shall be bedded as necessary to prevent settling or shifting of the tank. 2.3 Ail pipe connections to the septic tank shall be equipped with waterproof mechanical couplings. A cleanout shall be installed within 5 feet of the house foundation. A double cleanout whal] be installed within 5 feet downstream of the septic tank. 3.0 SOIL ABSORPTION DRAINFIELD: 3.1 The soil absorption drainfield shall be a deep trench constructe& to the dimensions shown on the drawings. The 9' deep by~,'Sfoot long trench shall be level. The trench shall be dug parallel to the contour of the lot. A total depth of 6.5 ft. of sewer rock shall be placed in the trench with 6 ft. of rock beneath the 4 in. perforated drain pipe. 3.2 Sewer rock shall be 0.5 - 2.5" screened gravel, with less than 3 % passing the #200 sieve. 3.3 Cleanout pipes and monitor tubes shall be 4" diameter and installed in locations shown on the drawings. The portion of the monitor tube extending through the sewer rock shall be perforated. 3.4 Approved filter fabric shall be placed over the top surface of the sewer rock. A minimum of 2 feet of soil cover is to be placed over the filter fabric. If the soil cover thickness is less than 3 feet, two inches of rigid, burial type insulation will be placed over the entire top surface of the sewer rock. 4.0 INSPECTIONS: 4.1 A minimum of three engineering inspections will be required during construction of the system. One after setting of the septic tank, one after excavation of the deep trench prior to placement of the sewer rock, and one after placement of the sewer rock and the perfoorated drain pipe and the clean outs and monitor tube. 4.2 The contractor shall coordinate with the engineer at least 24 hours prior to start of construction. PROBABLE IMPACTS TO ADJACENT PROPERTIES A) WELLS: The proposed disposal system is designed in accordance with the current 1994 Municipal Wastewater Disposal Regulations. The separation distances from wells on adjacent properties is greater than 100 ft., and the proper separation from the bottom of the trench to the ground water table is maintained, there should be minimal impact to adjoining propderty from this system. B) WASTEWATER SYSTEMS The size of this lot should minimize the impact on wastewater systems. adjacent C) RESERVED SPACE/SURFACE AND SUBSURFACE There is enough space on this lot to put replacement system and still maintain the required radiaa between wells and the disposal system. in another protective D) DRAINAGE The location of the disposal system will not interfere with any drainage. The area disturbed during construction of the system will be graded and sloped so as to not pond water. (,.,o,xV.,v. i"'~ 4---A Municipalily of Anchora e 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST N WAS GROUND WATER F(~ ENCOUNTERED? ., Reading Date Gross ~~ Net ~?th to Net ~ Time Time 'water Drop ~3 : ~1 I '~ ~. :~/~ PERCOLATION RATE , _ ( utes/Inc~[RO HOLE DIAMETER TEST RUN ~[TW[[N ~ FT AND ~' ~T ~* ¢~ CERTIFY THAT THIS TEST WAS PERFORMED IN Z2-008 (Rev. 4/85> 1 2 3 5 6 7 8 9 I0 12 14 17 18 20, DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 2 3 5 6 7 10 ~ WAS GROUND WATER  ENCOUNTERED? I IF YES, AT WHAT ..- __ __ 12 DEPTH? OepthloWaterA,e~.,~.~ ~ /~ ~1 1 3 Monitoring? _. /V~N~ Dale:'--~-~ 14 Reedin9 Date Gross Net Depth to Net Time Time Water Drop b~. t-~f~ :cfi ,, : .s ~.~ ¢ ,-~-- ~/.~ 20- PERCOLATION RATE ~' (mmutes/,nch) PERC HOLE DIAMETER /TEST RUN BETWEEN Tx 0 FT AND%~:> ACCORDANCE WITH ALL STATE AND ~NICIPAL GUIDEUNES iN EFFECT ON THiS DA,E. DATE:..I,. ¢/X /¢ 72-008 (Rev. 4/85) SOILS LOG -- PERCOLATION TEST . , ~ l~ LEGAL OEsOR,PT,O./_4. z~3 ~d/O~¢¢ ¢/¢~O~n~hi., .an.e. sec~,o.:¢~¢ 'i DEPTHS !MEASURED FROM:~] casing~. tdp' [] g~'ou~d 'S'[Jrfa~e BOREHOLE DATA: Depth Material 'Ty Color From To Depth of ho] Depth of' cas DEPTH'TO STATIC WATER LEVEL: · ~/ ftbelow ~ top of casing [] ground surface METHOD OF DRILLING: /r~ air rotary [] cable tool [] other ' USE OF.WELL: ~ domestic []irrigation [],'monitor [-I:public'supply [] other WELL:INTAKE OPENING TYPE: [] open end [] screened [] perforated ~. open hole Depths Of openings: to __ ft SCREEN TYPE: 'Slot/Mesh Size: GRAVEL PACK TYPE: Volume-used: GROUT TYPE: Depth: from DEVELOPMENT METHOD: Duration: _ _ Diem: in. Length: ft Depth to top:. Volume: _ ft to ft MunJcJpa ity ge aND YIELD: ~ hrs pumpin0 .~ gpm . . DEPTH: . ft Horsepower: D UPON COMPLETION~ 'YES"~-'~O S 0~ature of Author zed R~s~ ;s~wN .... '~' ~ ~ ~ ..... "n..,n.,, ....... [~ COPY OF LOG TO: '- ' ..... , .... ou]cst, Sute800 ' . ' P~ne"(907.}269,8639; Fax {907)562.1"384 PAGE 1 OF MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL SYSTEM PERMIT PERMIT NUMBER:SW960145 DESIGN ENGINEER:JAMES SIZEMOORE & ASSOCIATES OWNER NAME:YOUNG ALBERT K & VALERIE J OWNER ADDRESS:PO BOXl12071 ANCHORAGE, AK 99511 DATE ISSUED: 6/24/96 EXPIRATION DATE: 6/24/97 PARCEL ID:02102114 LEGAL DESCRIPTION: SPENDLOVE VIEW HEIGHTS BLK 3 LT 6 LOT SIZE: 58601 (SQ. FT.) HUMBER OF BEDROOMS: 4 THIS PERMIT: 4 THIS PERMIT IS FOR THE CONSTRUCTION OF: WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80) . 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWIHG SPECIAL PROVISIONS. SPECIAL PROVISIONS RECEIVED BY: ~~/2~.'~ ISSUED BY~i~2 / .L,~ BLS ,_,cp.F../,,,/~LOVE.. /-t E.'[ G h/T 5 .s u 5 Lb. .' %/TE. F'L.,A N/ Applicant Location: MUNICIPALITY OF ANCHORAGE Department Health and Environmental rotection 825 ~ Street, Anchorage, AK. 264-4720 * * ~ HANDWRITTEN PERMIT * * * W~LL AND/OR ON-SITE SEWER PERMIT l-.~ ~.,~ ~...y Mailing ? L hone u er: Legal Description, CoT & ~ S ~-~,m.£~L¢(,~__ LOt Size, Type of Soil Ab~ption System Is: Trench: &~ Drainfield: Seepage Bed: Holding Tank: Maximum Number of Bedrooms: ~ Soil Rating(sq.ft/br) ! The Required Size of the Soil Absorption System Is: DEPTH (>? ( LENGTH.--~C'~/--- C¢ /" _ . GRAVEL DEPTH ¢~J-'-'/ WIDTH The length dimension is the length(in feet) of the trenc~ or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between the outfall pipe and the bottom of the excavation(in feet). * * REQUIRED SEPTIC(HOLDING) TANK SIZE = /~"~3 GALLONS * * ~ermit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent to this property and the number Qf residences.that the well will serve. * * * TWO(2) INSPECTIONS ARE REQUIRED * ~ * Backfilling of any system without final inspection and approval by this department will be subject to prosecution. .~inimum distance between a well and any on-site sewage disposal system is 100 feet for a private well or 150 to 200 feet from a public well depending upon the type 2f public well. Minimum distance from a private well to a private sewer line is 25 feet and to a community sewer line is 75 feet. Well logs are required ~nd must be returned to this department within 30 days of the well completion. Dther requirements may apply. Specifications and construction diagrams are ~vailable to insure proper installation. * * * PERMIT EXPIRES DECEMBER 1 9 3 * * * I certify that: (1 I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2 I will install the system in accordance with codes. (3 I understand that the on-site sewer system may require enlargement if ther'~1esidence~i~re~modeled to include more th~ bedrooms. S igne~: '/'~ J~__ ..... Applicant ..... SWP/024(1/81) SOILS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST PERCOLATION TEST 1 2 3 5 6 7 8 10 11 12 13 14 15 16 17 18 19 20 SLOPE WAS GROUNO WATER ENCOUNTERED? DATE PERFORMED: "~/~, · SITE PLAN IF YES. AT WHAT DEPTH? COMMENTS /~/ ~.~ ~..J' Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE ~3 (minutes/inch) TEST RUN BETWEEN ~' ''7 ~'' FTAND ~'/' 7" '~ ET PERFORMED BY: /7,~/'~,'~( /V~/o (--~.-- 72-00B (6/79) C ERTI Fl E DBY: '~'~J~~ Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage; AK 99507 www. muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 021-021-14 GENERAL INFORMATION Complete legal description Lot 6, Block 3, Spendlove View Heights Subdivision Location (site address) 13501 Spendlove Drive Anchorage, AK 99516 COSA # OSC. i\\ I\ C~ Expiration Date: '7-..,~2.. ~ - / / Current Property owner(s) Albert and Valerie Young Mailing address P.O. Box 112701 Anchorage, AK 99511 · Day phone 727-7200 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, COSA will be held by DSD for pickup. NUMBER OF BEDROOMS: Five (5)' TYPE OF WATER SUPPLY: Individual Well [] Individual Water Storage [] Community Class ~ Well [] Public Water System [] TYPE OF WASTEWATER DISPOSAL: Individual On-site [] Individual Holding Tank [] Community On-site [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the rePresentations,given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by,a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. Phone 522-7773 Date 4/12/2011 DSD SIGNATURE j./// Approved for Disapproved. Conditional approval for bedrooms. ,~ .".~,.~,,_ ~/_~.~. / !.o~- bedrooms, with the following stipulationS: By: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory (Rev. 11/05) X Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: ~/)''~ ~ '~ / / Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www. muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: A. WELL DATA Well type Private Date completed 7/3/96 Total depth 386 ft. Parcel ID: 021-021-14 Lot 6, Block 3, Spendlove View Heights Subdivision IfA, B, or C provide PWSID # Sanitary seal (Y/N) Y Cased to 23 ft. FROM WELL LOG Date of test 7/3/1996 Static water level Unknown Well production 2 WATER SAMPLE RESULTS: Coliform 0 colonies/100 mL Arsenic: N/D ug/I B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Tank size 1,500 gal. Foundation cleanout (Y/N) Y Date of pumping 3/1/11 C. ABSORPTION FIELD DATA Well Log (Y/N) Wires properly protected (Y/N) Casing height (above ground) AT INSPECTION 3/19/11 46.8 ft. 1.4 g.p.m. g.p.m. Nitrate 1.40 . mg/L Date of sample: 4/8/11 Number of Compartments Two Depression over tank (Y/N) ... N Pumper Denali Sewer and Drain Y >18 in. Date installed 6/96 Soil rating (g.p.d./ft2 or ft2/bdrm) 1.2 GPD/SF Length 53 ft. Width 3.5 ft. Total depth 9 ft. Eft. absorption area 636 ft2 Monitoring tube Date of adequacy test 3/19/2Oll Results (Pass/Fail) Pass Fluid depth in absorption field before test 63 in. Elapsed Time: 1,185 min. Final fluid depth 61 Any rejuvenation treatment (past 12 mo.) (Y/N & type) N For Five bedrooms Water added 787 gal. New depth 68 in. in. Absorption rate >= 750 g.p.d. If yes, give date System type Deep Trench Gravel below pipe 6 ft. Y Depression over field N Date installed 6/96 Cleanouts (Y/N) High water alarm (Y/N) Other bacteria 0 colonies/100 mL Collected by: A. Harala LIFT STATION Date installed "Pump on" level at~ Datum in. E. SEPARATION DISTANCES Size in gallons "Pump off" level at__ Cycles tested SEPARATION DISTANCES FROM WELL ON LOT TO: in. Septic tank/lift station on lot >100' Absorption field on lot >100' Public sewer main N/A Sewer/septic service line >25' Animal containment areas >50' Manhole/Access (Y/N) High water alarm level at Meets alarm & circuit requirements? On adjacent lots >100' On adjacent lots >100' Public sewer manhole/cleanout Holding tank N/A Manure/animal excrete storage areas in. SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Property line >5' Water main N/A Water service line >10' Wells on adjacent lots >lOO' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: N/A >100' Property line >10' Water Service line >10' Curtain drain None Noted F. COMMENTS: Absorption field >5' Surface water >100' Building foundation >10' Water main >10' Surface water >100' Driveway, parking/vehicle storage >25' Wells on adjacent lots >lOO' Septic System Inspection Completed by James Sizemore, P.E. in June of 1996. Fluid Depth in Absorption Trench is Currently 63". Total Effective Depth is 72". G. ENGINEER'S CERTIFICATION I ce~i~ that I have dete~ined th~u h field ins ections and ~view of Municipal ~co~s that th~gabOve ~ms a~ in on , · r Prln N m Michael E Ander~n P E Enginee s ' ted a e .... COSA Fee $ Date of Payment Receipt Number (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www. ci. anchorage, ak .us (907) 343-7904 Septic System Advisory Certificate of On-Site Systems Approval # 111119 During a recent adequacy test on the septic system for Block 3, Lot 6 of Spendlove View Heights subdivision, 63 inches of standing water was observed in the absorption field. This indicates that approximately 88% of the absorption area is inundated. Although this system passed the adequacy test, the remaining life expectancy may be limited. This advisory must be attached to all copies of the subject Certificate of On- Site Systems Approval bJ Z L.i.I Q. SPENDLOVE DRIVE PLAT NO, 68-57 SPENDLOVE VIEW HEIGHTS LOT 6, BLOCK 3 58,601 SoF, N 90°O0'O0"E 281.91' WELL GRAVEL DRI PAVERs - RETAININg EXISTING ~3UILDING 50.9' SEPTIC SYSTEM VOLLEYBALL COURT BUILDING DETAIL SCALE: 1 "=20' AS BUILT ........ ' --' I HEREBY CERTIFY THAT I HAVE SURVEYED THE .... PROPERTY DEPICTED ABOVE ANB THAT NO GASTALDI LAND ENCROACHMENTS EXIST EXCEPT AS INDICATED. SURVEYING, LLC IT IS THE RESPONSIBIUTY OF THE OWNER TO JEFF A. GASTALDI, R.LS. DETERMINE THE EXISTENCE OF N4Y EASEMENTS, 2000 E. DOWLING RD., SUITE 8 COVENANTS OR RESTRICTIONS WHICH DO NOT ANCHORAGE, ALASKA 99507 APPEAR ON THE RECORDED SUBDIVISION PLAT. PHONE 248-5454 UNDER NO CIRCUMSTANCES SHOULD ANY DATA GRID DATE HEREON BE USED FOR CONSTRUCTION OR FOR 2942 8/25/2010 ESTABLISHING BOUNDARY OR FENCE LINES. ........... ANCHORAGE RECORDING DISTRICT, ALASKA FoB. JOB NO. NOTE: NO CORNERS SET THIS DATE. 98-03 SVH63 1"=40' SGS Ref.# 1111314001 Client Name Anderson Engineering Project Name/# Spendlove View Hghts Subd /:5 - .~ 2 ._ ~ Printed Date/Time 04/15/2011 9:28 Collected Date/Time 04/08/2011 13:45 Client Sample 1D Spendlove View l-tghts Subd Received Date/Time 04/08/2011 15:42 Matrix Drinking Water Technical Director Stephen C. Erie PWSID 0 Sample Remarks: Allowable Prep Analysis Parameter Results LOQ Units Method Container ID Limits Date Date Init Metals by ICP/MS Arsenic ND 5.00 ug/L EP200.8 C (<10) 04/12/11 04/14/11 SCL Waters Department Total Nitrate/Nitrite-N 1.40 0.100 mg/L SM20 4500NO3-F B (<10) 04/12/11 AYC Microbiology Laboratory E. Coil Negative 1 100mL SM20 9223B A 04/08/11 DLC Total Colilbrm Negative 1 100mL SM20 9223B A 04/08/11 DLC