HomeMy WebLinkAboutSTORCK BLK 3 LT 1 Municipality of Anchorage On-Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP231216 PID Number: 017-091-07 Dwelling: X Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New 0 Upgrade Name Margie Hudok ABSORPTION FIELD El Deep Trench Wide Trench El Bed El Mound Site Address 7220 Clarks Rd ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade (907) 748-3656 Three(3) 1.2 GPD/SF 5.8/6.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 3.8/4.0 Ft. Gravel depth beneath pipe 2.0/2.0 Ft. Subdivision Block Lot Storck 3 1 Fill added above original grade 1.3/0.2 Ft. Gravel length 44/44 Ft. Township Range Section Gravel width 5.0/5.0 © Ft. Beds: Number of Lines n/a Distance between lines n/a Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches 2 Dist. between trenches >6 From Tank Field Tank Line 440 Ft2 Ft. Well >100' >100' N/A N/A >25 TANK 0 Septic ❑ S.T.E.P. ❑ Holding ❑ other Manufacturer Infiltrator Capacity 1,060 Gal. Surface Water >1 >100' N/A N/A Material Plastic Number of compartments 2 Lot Line >5' >10' N/A N/A NA Foundation >1 0' > 10' N/A N/A L TION Manufacturer Capacity i Remarks 4" tank insulation. Trenches listed west/east Gal. Exposed end of existing trench & confirmed 5' tank separation Alarm location Electra i alled by PIPE MATERIAL House to tank D3034Tank to D3034 drainfield Installer Precision General Contractors Drainfield D3034 Co/MTD3034 Inspector M. Jakubisin BENCH MARK (Assumed elevation) 100 ft Inspection 1st 8/29/23 8/29/23 Location and description nd dates: 4th Lower Sliding Door Threshold 3rd 8/30/23 ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp OF �q Conditional Approval: Date ' , * *:49THjantai BenCE12592i11er ��¢ �'; Septic Syste Approved • ��'sjF9�0 Date .9/5/23 .�Aiw pROFESSIQ0 N : this approval does not include well permit requirem nts (Rev 05/02/111Y 9 6 0 . 0 9 7 0 . 0 9 8 0 . 0 9 9 0 . 0 9 5 4 . 0 95 6 . 0 9 5 8 . 0 96 2 . 0 9 6 4 . 0 9 6 6 . 0 9 6 8 . 0 9 7 2 . 0 9 7 4 . 0 9 7 6 . 0 9 7 8 . 0 9 8 2 . 0 9 8 4 . 0 9 8 6 . 0 9 8 8 . 0 9 9 2 . 0 9 9 4 . 0 Benjamin Schiller CE 12592R E GISTEREDPROFES S I O N A L E N GINEER 1"=50' CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE DV - DIVERTER VALVE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND 2CO2 MT2 TH#1 PERMIT # OSP231216 PID # 017-091-07 STORCK SUBDIVISION, BLOCK 3 LOT 1 2CO1 39.7 MH 83.6 2CO2 91.4 DV 93.5 15.0 73.2 81.9 83.6 FEET 0 50 100 2CO1 CL A R K ' S R O A D 3-B D R M H O M E AS-BUILT PLAN 9/4/23 20' CEA POWER EASEMENT DECK EXISTING TRENCHES TO REMAIN IN SERVICE NEW 1,060 GAL SEPTIC TANK CONFIRMED 5' SEPARATION FROM SEWER ROCK MT3 CO2 CO3CO1 CO4 TH#2 EXISTING WELL MT1 MT4 DV 2x 40' TRENCHES, 5' WIDE, 2' EFFECTIVE DEPTH TRENCHES WERE INSTALLED PARALLEL TO ACTUAL SLOPE. MT MT CO1 107.9 MT1 110.7 CO2 147.7 122.8 125.2 163.2 A B A B MT2 147.8 CO3 107.6 MT3 113.4 CO4 147.9 MT4 145.2 162.8 126.1 131.2 165.6 163.3 SV 89.279.4 CO CO CO CO BM PROFILE AS-BUILT (NO SCALE) 92.8 89.0 93.5 96.8 FC O MH SV 1060 GAL INFILTRATOR TANK 97.6 FINISH GRADE 40' DRAINFIELD ROCK MT 1 TH # 2 WATER AT 84.3 8/2/23 90.5 92.5 CO 1 CO 2 84.3 96.3 ORIGINAL GRADE MT 2 2C O 92.7 Benjamin Schiller CE 12592 R E GISTEREDPROFES S I O N A L E N GINEER 9/4/23 PERMIT # OSP231216 PID # 017-091-07 STORCK SUBDIVISION, BLOCK 3 LOT 1 TRENCH #1 - WEST TRENCH TRENCH #2 - EAST TRENCH 96.8 FINISH GRADE 40' DRAINFIELD ROCK MT 3 TH # 2 WATER AT 84.6 8/2/23 90.6 CO 3 CO 4 84.6 96.6 ORIGINAL GRADE MT 4 98.0 92.6 90.5 92.5 90.6 92.6 INSULATION MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP231216 Work Type: Septic Upgrade Tax Code Number: 01709107000 Site Legal Address: STORCK BLK 3 LT 1 G:3039 Site Mailing Address: 7220 CLARK'S RD, Anchorage Owner: GRAY REBECCA B Design Engineer: FORGE ENGINEERING This permit is for the construction of: Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Effective Date: Expiration Date Lot Size in Sq Ft Total Bedrooms: cnt Department 8/21/2023 8/20/2024 57064 ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: 'S S � 70 F-0,12— Ci C Date: Issued By: �� � Date: � 2/ �2 3 MUNICIPALITY OF ANCHORAGE Community Development Department � Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 017-091-07 Property owner(s) Margie Hudok Mailing address 7220 Clarks Road, Anchorage, AK 99516 Site address 7220 Clarks Road, Anchorage, AK 99516 Day phone 907-748-3656 Legal description (Sub'd., Block & Lot) Storck Subdivision Block 3 Lot 1 Legal description (Township, Range & Section) Lot Size 57,064 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field Initial 0 Single Family (SF) ❑X Septic Tank ❑X Upgrade El(w/wo AD U) Holding Tank ElRenewal ElDuplex (D) ❑ Privy ❑ Multiple Dwellings ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (signature of property owner or authorized agent) Permit/Rush Fees: 22 57 -1' 370 Waiver Fees: Date of Payment: 2,0 '-LO2 Date of Payment: Receipt Number: 9 Y -O Receipt Number: Permit No. {D 2.3 I2 -I C; Waiver No. S/g12 3 D�! 230 Permit App_ - : , �.,:C M M q 1637 \ \oZARkSRo 3' qo R444-46' N _ S 89059'10" E EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE RECORDED SUBDIVISION PLAT (66-53) ARE NOT SHOWN HEREON. THIS DOCUMENT DOES NOT CONSTITUTE BOUNDARY SURVEYAND IS SUBJECT TO ANY INACCURACIES THATA SUBSEQUENT BOUNDARY SURVEY MAY DISCLOSE. UNDER NO CIRCUMSTANCES SHOULD ANY OF THE DATA HEREON BE USED FOR CONSTRUCTION OF FENCES, IMPROVEMENTS, OR FOR ESTABLISHING PROPERTY BOUNDARIES. THIS SURVEY REPRESENTS A MORTGAGE LOCATION SURVEY PREPARED IN ACCORDANCE WITH THE ASPLS MORTGAGE LOCATION SURVEY STANDARDS. THIS MORTGAGE LOCATION SURVEY SHOULD ONLY BE USED FOR A SINGLE PROPERTY TRANSACTION. RE -USE OF THIS DRAWING BY THE ORIGINAL CLIENT OR BY OTHERS, FOR ADDITIONAL USES ATA LATER DATE WITHOUT EXPRESS CONSENT OF THE SURVEYOR IS A VIOLATION OF FEDERAL COPYRIGHT LAW. UNLESS GROSS NEGLIGENCE IS DISCOVERED, THE LIABILITY EXTENT OF THE PREPARER SHALL BE LIMITED TO THE AMOUNT OF FEES COLLECTED FOR SERVICES IN PREPARATION OF THIS PRODUCT. JOB # 23139 I NO CORNERS SET THIS DATE I SCALE 1" = 40' 0bo" 'w I ITII ITv. 1111, ' Y \,7, EO EO - 0 20' 40' AS -BUILT I HEREBY CERTIFY THAT I HAVE SURVEYED THE FOLLOWING DESCRIBED PROPERTY: LOT 1, BLOCK 3, STORCK SUBDIVISION ANCHORAGE RECORDING DISTRICT, ALASKAAND THAT THE VISIBLE IMPROVEMENTS SITUATED THEREON ARE WITHIN THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS EXIST EXCEPTAS INDICATED. DATED THIS 31 st DAY OF AUGUST, 2023, ATANCHORAGE, ALASKA. FIXED HEIGHT, LLC C.O.A.122554 Land Surveying Services 907.290.8949 225 W 23rd Ave., Anchorage, AK 99503 WWW.FIXEDHEIGHTCOM August 7, 2023 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Storck Subdivision Block 3 Lot 1 - 7220 Clarks Road Septic System Replacement Dear On-Site Services Engineer: The owner of the above lot has a septic system that has reached its end of useful life, so we are submitting this permit application for its replacement. The attached site plan identifies the location of the home as well as the wells and septic location. No conflicts exist between this proposed system and any other wells or septic system, whether on this lot or adjacent lots. We are replacing the septic tank with the same size designed for 3 bedrooms. The property is fairly flat in general, as is the area where the new trenches are designed. There are no slopes greater than 25% within 50’ downslope. Stormwater drainage will not affect this system, and the new trenches will be constructed parallel to the slope as much as possible. The new septic system will be a minimum of 100’ from all wells and surface water. Please refer to the attached test hole logs, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231216, Curtis Townsend, 08/21/23 // // // // // // 9 6 0 . 0 9 7 0 . 0 9 8 0 . 0 9 9 0 . 0 9 5 4 . 0 95 6 . 0 9 5 8 . 0 96 2 . 0 9 6 4 . 0 9 6 6 . 0 9 6 8 . 0 9 7 2 . 0 9 7 4 . 0 9 7 6 . 0 9 7 8 . 0 9 8 2 . 0 9 8 4 . 0 9 8 6 . 0 9 8 8 . 0 9 9 2 . 0 9 9 4 . 0 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 1"=50' CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE DV - DIVERTER VALVE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND 2CO MT TH#1 STORCK SUBDIVISION, BLOCK 3 LOT 1 FEET 0 50 100 FCO CL A R K ' S R O A D 3-B D R M HO M E SEPTIC PLAN 7/17/23 FS 20' CEA POWER EASEMENT DECK DECOMMISSION EXISTING 1000-GAL SEPTIC TANK PER UPC EXISTING TRENCHES TO REMAIN IN SERVICE NEW 1,000 GAL SEPTIC TANK MT CO CO CO COTH#2 EXISTING WELL MT MT DV 2x 40' TRENCHES, 5' WIDE, 2' EFFECTIVE DEPTH MAINTAIN 100' FROM WELL, 10' FROM PROPERTY LINE, AND 6' SEPARATION FROM EXISTING TRENCHES Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231216, Curtis Townsend, 08/21/23 TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 6" 4' 2' DESIGN FACTORS:SYSTEM REQUIREMENTS: 450 GPD PEAK FLOW PERK RATE: 1.2 MIN/IN APPLICATION RATE: 0.8 GPD/SF (CONSERVATIVE) 5-WIDE TRENCH SYSTEM 1000-GAL SEPTIC TANK BOTTOM OF TRENCH: 6.0' BELOW GRADE FLOW LINE ELEVATION: 4.0' BELOW GRADE 450 GPD / 0.8 GPD/SF / 5' WIDE * 0.70 RED FACTOR [2' DEEP] = 78.8 LF TRENCH REQUIRED (80 LF SPECIFIED) GEOTEXTILE FABRIC 8/18/23 PROVIDE ADDITIONAL MIN 6" FILL TO ACCOUNT FOR SETTLEMENT 5' STORCK SUBDIVISION, BLOCK 3 LOT 1 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231216, Curtis Townsend, 08/21/23 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 DEPTH (feet) TEST HOLE 1 DATE READING START TIME NET TIME (minutes) DEPTH to WATER NET DROP PERCOLATION RATE: (MIN/INCH) (inches)(inches) DATE OF MONITORING WAS WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING IF YES @ WHAT DEPTH? 1.2 7/25 1 2 3 4 5 6GM (SILTY SANDY GRAVEL) Professional Engineers Stamp: Yes Storck B3 L1 7/25/23 017-091-07 Rebecca gray 1:51 1 1' OB 5:38 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER PERC TEST LOCATION TECHNICIAN: M Jakubisin 7 12' 12' 8/2/23 COMMENTS: SITE PLAN 6 0 16 USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED 8/7/23 1 7 6 0 16 1 7 6 0 16 1 7 6 0 16 1 7 6 0 16 1 7 6 0 16 6:10 6:51 6:52 7:12 7:09 TH#1 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231216, Curtis Townsend, 08/21/23 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 DEPTH (feet) TEST HOLE 2 DATE READING START TIME NET TIME (minutes) DEPTH to WATER NET DROP PERCOLATION RATE: (MIN/INCH) (inches)(inches) DATE OF MONITORING WAS WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING IF YES @ WHAT DEPTH? 3.3 7/25 1 2 3 4 5 6GM (SILTY SANDY GRAVEL) Professional Engineers Stamp: No Storck B3 L1 7/25/23 017-091-07 Rebecca gray 3:05 1 1' OB 30:00 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER PERC TEST LOCATION TECHNICIAN: M Jakubisin 7 - - 8/2/23 COMMENTS: SITE PLAN 6 0 16 USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED 8/7/23 1 6 8 16 5 8 16 1 4 10 16 1 3 15 16 1 3 0 16 1 3 1 16 10:00 10:00 10:00 10:00 10:00 5 10 16 4 15 16 4 0 16 4 1 16 TH#2 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231216, Curtis Townsend, 08/21/23 l A c . i +ri C. ^ r. � / ZO POKIER ESMT F r? BARlJ AS 4 c r -4 vlwo 8z.z� N Sao 00'W $TOR. .1 �l 14 XA �ef'Cl W033114r,IS,# zcy4ELL, �4 34. i tf \, roIS `�. Q SEWER i YrNrS iOp �, SCALE J "- !JO' �� LEAC�.r I�IFr P1ELD NO I-.• bi a I V EASEMENTS OF RECORD, OTHER TOM THOSE W- N ON THE RECORDED ti PLAT, ARE: NOT SHOWN HEREON, I As Built NBA a 59'/O" j�/ /ro7. 72 No Corners Sit This Data Book No. Page No. �lCF I herei,y certify that I hove surveyed the fotlowing described property, Lot-1,._e1mit w OF Ak 51 DRC sS 5 V t p. Anchorpe recording Precinct, Alaska, and that A. eeee'�ei ee+„mss h the improvements situated thereon are within the property lines end do not overlap or (y ' ♦�,�+, oncroach on the property lying adjacent thereto, that no Improvements on property lying ediscom thereto encroach on the promisee In questlon and that there ere no• roadways, �e a ea s •re eee...e e transmission lines or other visible easements on'seid propirty'except as indicted hMeon. lie.e�NM N.7.e.M a of sae; eM Id Z Carts Hilda ON. ' I No. 13M4 Anchorage, Alaska • �FOe�ee. eeeMee i�h��ESitOttAL�OF Municipality of Anchorage Page DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: ~,,~- O~J~ PIDNumber: Ol'7'-'O~/-- Name: L (V!.C,[~-~ 'V,~.II,./ Wastewater System: [] New ~'Upgrade Address: -/~P-o ~{~ ~-~ ABSORPTION FIELD Phone: ~-- ~Z~ IN°'°fr~cOrns: [D Deep Trench ~ShallowTrench [3Bed []Mound [3 Other Total Depth from original grade: LEGAL DESCRIPTION S°il"ati"g:, /~ GpD/sq. pt. Lot: J BIock:~ Subdivision:~T~ ~ I.~. 3epth to pipe bottom from oriDinal gl~d e: FL Gravel depth beneath~pipe Ft, Township:l~''II Ran% Sec_~ Fill added above original grade:(~ Ft. Gravel length:~)~ (:~2~ Ft. WELL: [] New [] Upgrade Gravel~.J~lF ~,¢¢~4~. Numberofll~es: JOistancebetweenlines: ~ Ft. ~:~ t 0 Ft. Classification (Private, A,B,C): Total Depth: Cased To: " Total absorption area: Pipe material: Yield: GPM IPump Set at: Ft. ICasing Height Ab°va Gr°und:Ft. TANK SEPARATION DISTANCES ~ii~Septic [] Holding [] S.T.E.P. To Septic Absorption Lift Holding Pub m/P ~vate Manufacturer: Capacity in gallons: From Tank Field Station Tank SewerLines //~.~.~.~.~H~. ~-~b4. t~..,. we, t~-/ I o 2 ~/A t~/^ r~/,,A Uafer~:.~T.~l__. NumberofCompa,tments: Surface LIFT STATION Water ~ IC~:> ~ J:c'~3 Lot (~ { Line ,~) ~ ,~ ~ Size in gallons:I Manufacturer: t "Pump on" level at: "Pump off" level at: High water alarm at: F°undati°n '7~ Curtain Drain ~"~ l {..) ~' [ ~::) ~)~ [ [ Pump Make & M°de' I Electrical 'nspecti°ns perf°rme! bY: Remarks: BENCH MARK /ENGINEER'S SEAL Inspections performed by: ~,,~ Dates: 1st qo--, 'o~~~. 'Department of Health and Human Services approval ~;:,,~.;,>~ 72-013 (1/91) MOA 25 --I- __1 m I 104 9~[ 114 I 100 APP, E~GE DF 3£G ~$ 0 N 50 7.5 I00 Ip5 S£bLE; I' = 50 FI, TOBBEN SPURKLAND P,E, 203 W 15TH, AVENUE ANCH, AK, 99501 LL1T £ .BLLICK 3 STDRCK S/D LINDA KELLY 7220 CLARKS SEPTIC SYSTEM ASI)UILT ~A'rE, April Ip, 1992 SHEET, 2/3 OR~D, 3039 0 Monitor Clean [2ut _1 ~/ide Trenches: 5' Idfde £' Sewer rock 3' Cover 5 SCALE 5 ] ~ 1000 gal Septic tank Foundation Clean ou~; Miro£! I40 24 in o¢' tep~clc Rock Cleanou~cs -~. /~ Monlq;or S' Cover / / 85,5 boffo~ ~:,~'~hol~ N~ SCALE /' Ex/st, Ground ~~over Tank 1000 gal, sept:lc tank TBBBEN SPURKLAND P.E, 203 Vl5th Ave Anchorcoe Ak 99501 LDT 1 J~LDCK 3 £TDRCK S/J9 SECTIL1N $~ TI~N, R$1V LINDA KELLY SEPTIC SYSTEM ASBUILT ])~T~, April 13~ 199~ SHEET, 3/3 GRIll, 3035 PAGE 1 OF MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW920044 DESIGN ENGINEER:TOBBEN SPURKLAND, P.E. OWNER NAME:KELLY RICHARD P OWNER ADDRESS:7220 CLARKS ROAD ANCHORAGE, AK 99516 DATE ISSUED: 3/27/92 EXPIRATION DATE: 3/27/93 PARCEL ID:01709107 LEGAL DESCRIPTION: STORCK BLK 3 LT 1 LOT SIZE: 57064 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: '/~ ISSUED BY: 203 8 ~NCHO~AGE~ (907) 27%~918 LOT SEPTIC SYSTEM DESIGN BLOCK 3 STORCK LINDA KELLY Impervious L_ayer ( Bed Rock ) at 11 ~t. LJse Wi de Trench Soil Rating. From test Feb. 1'7~ 1992 15 rain/in = .8 gal/min Required Area per' Bedroom: 150/.8 = 187.5 squat.. Finished Floor Elevation Lowest Floor Fouodation Cteao Out Elevation Ground Sur'~ace at Absorption Field 100.00 96,, 96-97 Testhole Total Less 6 ~eet Rock Depth Reduct ioo Factor Depth 11 5 2 2 .7 Number of Bedrooms 3 Ler~gtln o-F Trench 187.5 x 3 x .7 / 5 = 78~75 SYSTEM CONFIGURATION WIDE TRENCH TOTAL LENGTH BO FT. TOTAL WIDTH 5 FT. TOTAL DEPTH 5 FT. BOCK DEPTH 2 FT. COVER 5 FT. SEPTIC TANK 1000 GAL. ABANDON EXISTING SYSTEM PUMP AND CRUSH EXISTING TANK PUMP, C~USH, AND BACKFILL EXISTING PIT Septic System Design L. ot 1 Block 3 Storck S/D The installation eq this septic: system will not prevent ~,ells ~rom be iostalled on the adjacent lots. There are nc) devel(:)p~?d c)r natL~ral surqac:e / sub sul'"~a(=e drainage c:our~.,.es on this or the adjacent lots. The proposed septic system wilt not change the general slope of the area. F'onding and/or ~or',centratioc, o~ sur'~ace runo~: will not result .~:rom this installation. Septic System Design Lot 1 Block 3 Storck S/D pg. 2 APP. Eg~E £F ££--G ~'~ £CALE; I' -- 100 FT, TOBBENSPURKLAND P.E,II L£T!, 203 W J5TN. AVENUE ANCH. AK. 99501 (~ll7) P7'~-,3~16 ~gLOCK 3 STORCK S/~ LIN~ KELL ~ 220 CLA£KS ROAD SEPTIC SYSTEN DESIGN DATE, MARCH 4, 1992 SHEET, 1/3 GRID, 3039 ~ EXI$ TING INSTALL IOD8 GAL ~ TANK EXItTING CRI~ INSTALL B8 L,F. 5 FT. WIgE TRENCH 2 g 48 LIN FT, ~ 5O N 75 lO0 125 SCALE~ 1' = 50 FT, 150 TDBBEN SPURKLAND P,E. 203 W 15TH, AVENUE ANCH. AK. 99501 LI]T L $L£CK 3 ST£RCK S/B LINBA KELLY 7220 CLA£K£ RDAB SEPTIC SYSTEM DESIGN DATDMARCH ~ 1992 SNEET, 2/3 GRID, 3039 Monitor · , CLEAN Cleon l]ut OUT [Vide Trenche_~ 5' ~ide 40' Long 5 · Mon/~cor .... - - CLEAN Clean Eu`c L]UT 5 ND SCALE J MlroFI 140 ~ 24 in o£ Sep~cic Rock ND SCALE TDBBEN SPURKLANI) P,E, 203 NdlD~ch Ave ~Anchor¢ge Ak 99501 LET ! BLDCK 3 STD£CK SECEIDN 35 TI~N, R3V LINDA KELLY 1000 gal Sep~clc `cank Exit`C, [;round 4' Mtn C_over ~over l'or~k gal, sep`c/c 'conk SHEET, 3/3 0Ri~,3035 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST LEGAL DESCRIPTION: 4- 5- 6- 7 8 9 10 11 12 13 14- 15 16 17 18 19 2O DATE PERFORMED: Township, Range, Section: SLOPE WAS GROUND WATER ENCOUNTERED? I]eplh to Water Aiteri% Gross Net Depth to Net Reading Date Time Time Water Drop 2' PERCOLATION RATE / [~'' (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN FT AND __ FT COMMENTS .ER.O.MED BY: '~& , 3 --'-'-'J' CERTI., ~H^'. TH,S ~-ES~- WAS PE.PORMEO.. ^GOO.OANCEW,T.A..S¥^TEANOMUN,C,.^,_~U,DE,_INES,N~..ECTO.¥.ISD^.E. D^~-E: /-3,.,~.} '/ ~ 72-008 (Rev. 4/85) PERFORMED FOR: LEGAL DESCRIPTION: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16- 17- 18- 19- 20- Municipality o! Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST LI I~1 D ,z~ V_l~, Lt..",/ Township, Range, Section: SLOPE WAS GROUND WATER ENCOUNTERED? S L IF YES, AT WHAT O DEPTH? p E Depth to Waler After Monilering? Date: SITE PLAN Gross Net Depth to Net Reading Date Time Time Water Drop ~/~{~1~- 11: ~,~ ~',.~ ~.,~, .1~ I; e~, - 8 3/,~, PERCOLATION RATE ,'~,~ (minutes/inch) PERC HOLE DIAMETER ~ __ ,~ ~ TEST RUN BETWEEN ~_/FT AN.D ~ FT COMMENTS THAT T IS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 72-008 (Rev. 4/85) ]Sth. Awnue~ Suit~ AN~HORAGE~ ~L6SKA 99501 (907) 279-3916 SEPTIC SYSTEM DESIGN REVISED: APRIL 2 1992 LOT BLOCK ~ STOFt~CK LINDA KELLY Soil Rating,, From t. est March 3i~ 1992 .cc min/:i.n = .6 ~;al/min 1 ~../.6 = /:5" sq.ft.. Firli f~hE.d F'loor E! ~va/tion L.o~.~c~st F1 oor FoL~dation Clean Out E].ew~tion Gr'c~und ,.)t.~r'+ace at Absor'p'~ion F'iel d 00.00 96. 96-97 T~?s'~iho].c.~ To'kal Depth Les~s~ 6 f(m~.:et 7 Rock De_,oth, .)":" USE 2 FT. R~ed uc'k i on Fac:t: of .7 ?.5: ,~.: .}'; >,' .7 / ~S --: t-5 SYSTEM COI~Fi GURATi ON WIDE TRENCH TOTAL LENGTH 105 FT. TOTAL WIDTH 5 FTi TOTAL DEPTH 6 FT. ROCK DEPTH 2 FT. COVER 4 FT. SEPTIC TANK 1OOO GAL. ABANDON EXISTING SYSTEM PUMP AND CRUSH EXISTING TANK POMP~ CRUGH~ AND BACKFILL EXISTING PIT During layout o~: the prc.¥)osed septic~ system it was discovered that the drain~ield was not completely covered by the or'iginal testhole. A seco)nd testhole ~as dug adjacent to the proposed drain -~ield. No bedrock was ~ound at a total depth o~ 13 ~eet. A peat and loam layer was also .~:ound at the depth of the proposed dra~nfield,, Because of these observations it was decided to install the drain.Field bet~.~een 4 and 6 ~eet. The soil at this depth perc'ed at 22 rain/inch. The total length o-~ the -~ie]l.d was changed accordingly. '--" _~e. pL].c syst:em will not: prevent wells Yrom be instal led on the adjac:ent ].ots. resL.~].t ~r'om this :Lnsta].].at:Lc~n,, UHC C PA L0TY OF H C H0Rk„ G � Development Services DepartmentPhone: 907-343-7904 `� On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 017-091-07-000 Expiration Date: 12/8/2023 Legal description STORCK BLK 3 LT 1 Site address 7220 CLARK'S RD Anchorage AK 99516 Current property owner(s) GRAY REBECCA B X The On-site system(s) is/are approved for 3 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: MOA is still waiting for pending water test results for Arsenic Original Certificate Date: 9/8/2023 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist Absorption Field Advisory Tank Age Advisory Other X Well Flow Advisory Nitrate Advisory Arsenic Advisory COSA ApprovaIjune 2022 MUNICIPALITY OF ANCHORAGE 'T ---- Development Services Department ` Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application --- ,6, a 1. GENERAL INFORMATION Parcel I.D. 017-091-07 Complete legal description Storck Block 3 Lot 1 Location (site address) 7220 Clark's Road, Anchora Current property owner(s) Rebecca Gray 2. ON-SITE SYSTEMS SIZED FOR � BEDROOMS e, AK 99516 Day phone 3. TYPE OF WATER SUPPLY: ❑■ Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: X Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel X Plastic ❑ Concrete ❑ Fiberglass Age <1 yr - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑ Deep Trench ❑■ Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: 99 Distance: By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $ [ �i p Waiver Fee $ Date of Payment COSA# osu2 3 ►33 R Date of Payment Waiver # COSA Application—June 2022 1.11 ** *Noted on 1992 COSA (depth of bedrock) **Arsenic result is pending. Once the results are received, paperwork will be updated. N/A N/A N/A > Benjamin Schiller, P.E. (907) 522-7773 Well Nater Advisory Certificate of On -Site Systems Approval # OSC231338 Subdivision: Storck, Block: 3, Lot: 1 This well's productivity was determined to be 0.6 gallons per minute. The minimum well productivity required under (AMC 15.55) for a 3 -bedroom residence is 0.3 gallons per minute or 150 gallons per day per bedroom. Although the subject well currently exceeds this minimum requirement, the production capacity can fluctuate and may be insufficient to meet your needs. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. MEMO as-ig-7 �� Mail�ng�Address P t0 Box 196650 *�4nchorage; Alaska 995196650 * wvyw inun��org � � MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of EnvironmentaJ Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. # 01-}- Oqt-O -~ HAA# ~P GENERAL INFORMATION Complete legal description Location (site address or directions) '7~2.o C. Io. ¢~ f~O Property owner Mailing address Lending agency Malting address Agent Address Day phone Day phone Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: ~ k~ TYPE OF WATER SUPPLY: Individual well ~' Community well Public water NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. 4. TYPE OF WASTEWATER DISPOSAL: NOTE: Individual on-site X Holding tank Community on-site Public sewer If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72~)25(Rev, 1/91) Front MOA#21 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm i '¢ ~ Ja-¢-~-I ~ u ¥'[~,L t ~.~,~¢ Address ¢¢-.0 ~ bY/' ,/S/--~/ ¢¢ 206 I=ngineer's signature ~ / Phone Date Disapproved. Conditional approval for bedrooms, with the following stipulations: Additional Comments The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not r(;sponsible for errors or omissions in the professional engineer's work. 72~325 (Rev. 1/91) 8ack MOA #21  Municipality of Anchorage Department of Health & Human Services HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: '13> ~Jc(~'~-~'--- Parcel I.D. ~l~/-O~'- A. WELL DATA Well type Log present (Y/N) Total depth Sanitary seal (Y/N) If A, B, or C, attach ADEC letter. ADEC water system number Date completed '~'~ [ ~'70 Driller Cased to r/~ ~' ~ ~,~'~cJ~:asing height Wires properly protected (Y/N) FROM WELL LOG Date of test Static water level Well flow Pump level SEPARATION DISTANCES FROM WELL TO: Septic/holding tank on lot ~ O 7' Absorption field on lot I Public sewer main Sewer service line g.p.m. AT INSPECTION /'5o ; On adjacent lots ; On adjacent lots Pdblic sewer manhole/cleanout Petroleum tank WATER SAMPLE RESULTS: Coliform {~ Nitrate / Date of sample: L/. ~ C~2.- (~). ~'~ fl Other bacteria Collected by: B. SEPTIC/HOLDING TANK DATA Date installed ~='//~1 ] q z_ Cleanouts (Y/N) High water alarm (Y/N) Date of pumping Tank size J ~ O Compartments '~- Foundation cleanout (Y/N) ~ Depression (Y/N) ~///,~ Alarm tested (Y/N) /"~'///'-~' /~/~ Pumper SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: Well(s) on lot TO property line Surface water/drainage On adjacent lots Absorption field 72-026 (Rev. 7/91) Front Foundation Water main/service line ''' ' ~ I'' bONTINU'ED ON BACK PAGE C. LIFT S'rATION ~ Date installed Size in gallons Vent (Y/N) High water alarm level _ "Pump on" level at Manufacturer Manhole/Access (Y/N) "Pump off" level at Cycles tested Meets MOA electrical codes (Y/N) SEPARATION DISTANCE FROM LIFT STATION TO: Well on lot On adjacent lots Surface water D. ABSORPTION FIELD DATA I)ate installed ~/~//~-- Length __10 _~ Width .-~ Total absorption area Depression over field (Y/N) Results (pass/fail) - Peroxide treatment (past 12 months) (Y/N) Soilrating .~?,/P~J/ Systemtype I-~/;c¢¢- 7-4.c¢¢.4--~ Gravel thickness ~ Total depth ~ Cleanouts present (Y/N) ¢ Date of adequacy test ~///A- for ~ bedrooms If yes, give date SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Well on lot JO '7 To building foundation Onadjacentlots__ ~/~ Surface water ~ / ~ Curtain drain I%t/E::) On adjacent lots ?/¢J-¢ Property line ~-~ To existing or abandoned system on lot Cutbank t~//,~ Water main/service line Driveway, parking/vehicle storage area E. ENGINEI--FI'S CER'I'IFICATION I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. Signature_ '~--'~__ ,-.~~ Engineer's Name HAlt Fee $ _ // '~) '~' Date of .aym,;nt Receipt Number 72-026 (ltov. 3/91) Bl~ck MOA 21 Waiver Fee: $ Date of Payment Receipt Number //~],~X-'' D'EPARTM~-.,~ ~ HEALTH AND ENVIRONMER:-~[ )~OTECTION~~ i[~-~2tl I ~ 825 'L Street, Anchoraom. Alaska~99501 , ~ ~-'~J ~'V ~.-~~eiv~.~arch 16, 1978 ~1: Time 2:~0~.m. ~[[~O~Y~p~ ~3: Time Date ~78 Friday Date ~ Date Insp~Pr~t% Insp ~t% Insp REQUEST FOR APPROVAL OF INDIVIDUAL SEWER AND WATER FACILITIES 1. Lending Institution Request: Mailing Address: Phone: 2. Property Owner: Leland S/Lavrna M. Boatriqht Phone: Mailing Address: Post Office Box 1847 99510 344-1228 Legal Description: Lot 1 Block 3 Storck Subdivision Corner of Clark's Road/Rabbit Creek, rust house Single Family Residence: (x) Number of Bedrooms: Three Multiple Family Residence: ( ) Number of Bedrooms: Well System: Permit ~ Construction Individual Well (x) CommUnity/Public System ( ) Depth of Well 135' Well Log on File Bacterial Analysis ( ) Sewage Disposal Permit ~ Septic Tank Size Absorption Area System: On-site System (x) Public utility ( Installed 1967 Installer Manufacturer Soils Rate Material Distances: Well to Septic Tank to Absorption Area to Sewer Line Nearest Lot line Absorption Area to Nearest Lot Line ,4'UNICIPALITY OF ANCHORAGE ' : ;,' Department of Health and Environmental Protection 26 - 7 o for Approval of Individual Sewer and Water Facilities Property Owner: Mailing Address: Name of Buyer: Mailing Address: 2; Phone: Lending Institution: Mailing Address: Phone: Realtor/Agent: Mailing Address: Phone: Legal Description: Street Location, Single Family Residence: ~) Number of Bedrooms: Multiple Family Residence: ( ) Number of Bedrooms: 7o If Individual Well, well depth ~,~.~'/ If Community System, name of system 8. Sewage Disposal System: *~n-site System (~ Public System ( If On-site System, date of installation: /f ~ ~ Water Supply:. *Individual Well ~) Public/Community System ( ) *NOTE: A well log is required on ALL wells drilled since 6/75. ** If on-site sewer system is over two(2) years old, an adequacy .test is required by this department. A fee of $25.00 must accompany each request before processing can be initiated. 3/77 Page~.Two Department of Health and Environmental Protection Request for Approval of Individual Sewer and Water Facilities Legal Description: Lot 1 Block 3 Storck Subdivision Comments: Affadavit Attache~d: ~) Approved: ~C. ~/~' Lette~ Attached: ( ) Date: ~' '"'""' ~"~-(~ '""' "~'~ P Disapproved: Date: Department Worksheet: