Loading...
HomeMy WebLinkAboutSTEFFES LT 33Cffes 33¢ #051 - 105-17 Municipality of Anchorage $UBMIr'Tu'a On-Site Water and Wastewater Program • (907) 343-7904 Page of b ON-SITE WASTEWATER INSPECTION REPORT SEP 0 4 2010 Permit Number: OSP151151 PID Number: 051-105-17 Dwelling: ® Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New ® Upgrade Name: David Benter ABSORPTION FIELD - EXISTING Address ® Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound PO Box 672218, Chugiak, AK 99567 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 3 -- GPD/SF -- Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot -- Ft. -- Ft. STEFFES 33C Fill added above original grade Gravel length Township Range Section -- Ft. -- Ft. Gravel width Beds:Number of Lines Distance between lines SEPARATION DISTANCES -- Ft. Ft. To Septic Absorption Holding Sewer Total absorption area Number of trenches Dist.between trenches From Tank Field Lift Station Tank Line -- Ft2 -- Ft. Well 100'+ -- 100'+ __ 25'+ TANK ®Septic ®S.T.E.P. 0 Holding ❑Other Manufacturer Capacity Surface Water 100'+ -- 100'+ -- ANCHORAGE TANK 1250 Gal. Material Number of compartments Lot Line 5'+ -- 5'+ -- STEEL 2 NA Foundation 5'+ -- 5'+ -- LIFT STATION Manufacturer Capacity Curtain Drain NAiy( 1<- NA -- Anchorage Tank 1250 Gal. Remarks Existing septic tank decommissioned Pump on level at Pump off level at High water alarm at per code. New tank and lines insulated. 44 in. 42 in. 48 in. Pump make and model Elec ical nspections performed by v � ,rQ LLC Franklin 2445040117-1/2HP PIPE MATERIAL House to tank D3034 Tank to D3034 Installer J Rs drainfield Drainfield -- CO/MT D3034 Inspector ARCTERRA BENCH MARK (Assumed elevation) 100 ft Inspdates:ection 1'6/5/15 2nd 6/11/15 Location and description 3'd 4th Bottom of Siding COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL 40„+•4441:No lik ,ar40 Conditional Approval: Date /�4`� A. \t'v4 I � / �4 `. CE 7111 / � � .."/>>IlI .. rt sstolo Approve �. ,-- V-7,___7-read...-4_ Date S-1 1 4\,,.-•". Inspection Report ST copy 3.doc AS-BUILT SYSTEM DETAILS/SITE PLAN Permit OSP151151 STEFFES LOT 33C PID# 051-105-17 2' CANT x B r Y ~ ® 28.0' Z c' W WELL U i 0 3i IN °° J N INSULATI I N ADDED TO r p CFI 37 iv LINES .,• HOUSE, R i= DECK FCO STE• do TO Fl �. �"`t' o LOT 33C ������� ADD.MT • �t��-,� Z w o — MT INSTALLED "VP, F— D R \ , CO EXISTING FIELD I° 00 O0— InOV o 6.0' X = C II/ CO D O cV r O2x10COz0N BW CANT II� I GRAVEL MH '6 Z O D ' `ft y x z 0 34.0' _ DUE TO SHALLOW 3527' C C A ELEVATIONS 1250—GAL c" X Q I STEP TANK INSTALLED 6 I x IM I I J N V 01 X Y 47, rn SHED o MT I N N 24.0' LY—x—x—x—x x - O co S89'57'34"E 153.61' (N89'59'10"E 153.07' R) 0 R Y I LOT 33B SCALE! 1' = 30' a i $o (101.8 101.7' I- A-C=31,6' o MB-C=52.0' ti I § A-D=29.9' FINAL GRADE B-D=58.0' I ORIGINAL GRADE F. VARA=S J o 12 0 ATIr4GAL .- .5. N STEP T TANK EXISTING FIELD 97.7 C.97.7 Lk)./ 1101 cn SCALE' NTS W / <S� �F At<Q\1 PREPARED FOR: CTERD orA� ' 1 DAVID BENTER �R"XIII P ' P❑ BOX 672218 o�' Y c * 4 9TH i' -/ * # Chuglak, AK 99567 a / 360-87-0646 (( Pib)'� ,cr / • KE•NNETH`� • S • / FIELD BOOKS COMPUTED s XNV` CE- u I BOUNDARY:BOUNDARY DRAWN: BMWZ •� 4 .1 • Ali/ /'s• ti STAKING: STAKING CHECKED' KMD `/ ''•1i 1 I �� ' ASBUILT: JLS DATE: 6/1115 + '� '�...�... o FESSIO _� `\_ DWG.FILE: GRID: N W1358 9G!, cc N N\Ac. 6^, ,� ACAD FILE: FILE Joe No.:15-151 `FR K.99577, 8 SWELL LOT 2 8 BASIS OF BEARING S89'59'20"W 153.07' (153.05' R) X —410 10' UTILITY ESMT r—x_--x—x—x—x --x— ,7 50' — W x 2' CANT X H C ®WELL 28.0' 4-1 LOT 33C Ew a04 o- z _Q -W C� N UI � - ry (n - C -' N N )1d0 C l iv-- DECK y O IW Z 1.-L.1 o — SEPTIC ?� O _ r— D \ tWP) O 2 p 6, 6.0' X =O "—2•x10' % ? 00 0 I E---)1Oc`l LL.I BW CANT • O N O O f-.� Z o GRAVEL z 11111I W z D/W o N Z O 34.0' U 52.7' CONC I X N I 01 1X > O O I SHED <?I • NK 24.0' 1) , V v y 1( 4- e 589'57'34"E 153.61' (N89'59'10"E 153.07' R) I LOT 33B ANCHORAGE RECORDING DISTRICT,ALASKA 0 = 1"IRON PIPE ASBUILT OF: STEFFES SUBDIVISION LOT 33c PLAT 67-166 �.���\Xxv OD S U SURVEY CERTIFICATE:I,John L.Schuller,Have conducted a physical survey of this property as shown on this drawing and that the j ��••O F''A•�`% yO pL LAND v.4)improvements situated hereon are within the property lines and no � ` IL enchroachments exist other than noted.Under no circumstance should / ' 49THany information on this drawing be used for construction of fences, I .structures,improvements,or for establishing boundary lines. r EXCLUSION NOTES:It is the owners res onsibili to determine / til the existence of any easements,covenants,or restrictions which JOHN L. SCHULLER: ��/ *� \`') do not appear on the recorded subdivision plat. LS-10408 'i . • MARK ORDER NUMBER: DATE: SCA/E: E-11/4L � -1831 Talkeetna Street JUNE 28, 2015 1"=30' 1;°p .6,v2-e).'t<j � (•,$), Anchorage, Alaska 99508 1)S-010 DRAM BY:CHECKED BY°"a'"" BOOK rAGE , fessionol L•� (907) 227-1455 office JLS NW1538 150214 \�\X‘"lb (907) 274-4992 fax ~--~UNICIPALITY OF ANCHORAGE ~._. Hea.] I and l~nvzronm(~ntal Protec Fourth Floor West 825 L Street Anchorage, Alaska 99501 264-4720 LOCA]~ON ~ ~ ~. ....... LEGAt_ DE~;CRIPTION SEPTIC TANK: NUMBER OF [)[SI/~NCE~B~ t,IAt4UFACIURENB_~S~ ..... h4ATERIAL __.~%~_~.~__~_COMPARTMENTS __ ~ TILE DRAIN FIELD: · T ~I',A L LENGTH [)iS'[/:,I,~('E [ ROM V/ELI ..... FOUNDATION ............... [NEAREST LOT LINE ................. OF [-INE ~ OE ~ihes ~ ..... DISIANCE GETWEEN [II~ES ~ _~g$.~TaENCH WIDTH$_~. IN. TOTAL EFFECTIVE :MPilh IOPOF THL I'(_) tIN$StlGR/'DE ~-/2~ _rv,AiERIAL[$ENEATHT LE.~_~__L._~.ABOVEI'ILE~ SEEPAGE PIT: DIAMETER ____ OR WIDT,'t ___, LENGTH ..... DEPTH ' ' · ])ept h: ~]1 Distance To: Lot Line tdg: Sewer Line: ' ,.lat_] _~1.~. of Bedroom.'~: ~ ' Loq Crib Rings Crib Size: DIAMETER .... DEPTH ..... DISTANCE FROM: WELL TOTAL EFF£CTIVE 13LJILI)IHG FC, UNDAI[C)H ~ NEARCSF LOT I_INE ~_~ ABSOflPTION AREA (WALL AREA) .......... Sq. FT. F'ERMIT N0. ,' r',e,e, 4 ', FFLI _.HMT t. 0 C R T I 0 N LEGRL JIM CRTLIN HELLuYR RORD L]:Z.':C z, TEFFE-, :.,UE,[. 825 '"L. STREET., RNE:HOP..RGE, BK. 279-25:L± P. 0. BO,~--: LOT SIZE 2±267 SQUARE FEET \0 /'~,¢~, ¢5 Mod TYPE OF SOIL RBSORBTION SYSTEM IS: DRRINFIELD MR2;IMIJM NIjMBER OF BEDROOMS = ~ ~OII_ RRTING THE.REQUIRED~ SI~¢'~THE SOIL RBSORPTION S,STErl I=,: _. -..-.. .. - -.- THE LENGTH DIMENSION IE[~ LENGTH (IN%EET) OF THE TRENC:H OR DRRINFIEL[.. THE DEPTH OF R TRENCH OR PIT IS THE DISTRNCE BETHEEN THE SURFRCE OF THE GROUND RND THE BOTTOM OF THE Eh',CRVRTION (IN FEET.'). THE TRENCH ~ [~NFZELD~IS Z .FEET. THE GRRVEL DEPTH I=, THE MINIMIJM DEPTH OF =BM,EL BETHEEN THE OLITFRLL PIPE RND THE BOTTOM OF THE EXCRVRTION (IN FEET). F::E,;~L~ Z [:EE:' SEPT Z C; F' R C: ~-::: R G E F' L R i'4 T el F' 'f ]; C" f-,~ R PRCI<RGE PLRNT MR"r' BE INSTRLLED RT THE PERMITTEE"S OPTION '_=;UBJECT TO THE FOLL. OIqING CONDITIONS: ±. EITHER R CLRSS I OR II NSF RF'PR'O'¢ED PLFINT MRY BE INSTBLLED. 2. R CONTINUOUS f"IRINTENRNCE RGREEMENT IS REQUIRED. IF R f"iRINTENRNCE RGREEMENT IS NOT KEPT CURRENT YOU MRY BE REQUIRED TO ENLRRGE THE SOIL RBSORPTION SYSTEM RND?OR "r'OU MRY BE SUBJECT TO PROSECUTION. ...... T t---It,:, ,:: ;.:' ::. Z I--~'~- F" E rS T I C,l".t'--.-~ F.4 F-: E F;:c E-.; L--:~ L~ Z RED E:RCKFILLtNG OF RNY SYSTEM HITHOUT FINAL INSPECTION FtND RPPF.'.O',/FtL Bk' THIS DEPRR]'MENT HILL BE SUBJECT TO PROSECUTION. MINIMUM DISTRNCE BETHEEN R HELL FIND RNY ON-SITE SEHRGE DISPOSRL SYSTEM IS :L00 FEET FOR R PF..'IYRTE [,]ELL OR 200 FEET FOR R PUBLIC HELL HELL LOGS FIRE REQUIRED FIND f,IUST BE RETURNED TO THE DEPRRTMENT HITHIN _--.':8 DR'CS OF THE HELL COMPLETION. OTHER REQUIREMENTS MRY FIF'PLY. 'SPECIFICRTIONS RND CONSTRUCTION DIRGRRP1S RRE FIVRILRBLE TO INSURE PROPER INSTRLLRTION. ; F-. E_. £-~ E C E f-1 B E F-: .~: ::L.. :.l PEF--:M Z T E.":-:,:F' .'[ ' '= ' I CERTIFY THRT ±: I RM FRMILIRR HITH THE DE:]_IREMENTS FOR uN-::,IrE SEHEP..S RND IIELL=, H=, _,ET FORTH E:'T' THE MUNICIPRLITY OF RNC:HnRRGE. 2: I WILL INSTRLL 'THE _-,~_,TEM IN RCCORDRNCE HITH THE L. ODE_. _-,: I UNDERSTFIN[:, TI-IRT THE ON-SI-rE _-,EHEF.. _~_TEH MRY REQUIRE ENLRRGEMENT IF ']-HE RE:.,IEEN_.E IS REMODELED TO INCLLtDE flJ~E THRN 7; EECRuuM_. ~//¢tF:F L i C:RNT JIM CFITL IN ISSUED B 'r~ :- -~/~-~~- -4~=~H .... DRTE ..... -~ ........... V]:. 0 " O~E CO. GEO/-'~CHNICAL 8- DEVEL/., MENT Box 90. Davis St., Eagle River, Alaska 99577 694 2774 or 688-2280 Russell Oyster 694-2774 Soils ~ Foundations Performed for: Legal Description: Depth (feet)_ 0 SOIL LOG Mailing Address_,' Soil ;Characteri stic) Tel. No. 7 lO 15 16 Ground Water Encountered: Yes No~_ If yes, what depth Proposed Installation: Seepage Pit.~ Drain Field " Comments'. Ear/Ellis 688-2280 Land Develooment Performed by: .:-- ,-,~L. , ,,:;,' ..... Date: t~',, "'~ :~ Well Owner Location Jemes Catlin DRILLING, DRILLING LOG []se of We]l Do~t. (address of: Township, Range, Section, if known; or distance main road Lot 33C ~iteffes Subd., Peters Creek Size of casing_ 6'' Depth of Hole Static water level 10 ff. Screen ( ); Perforated ( Describe screen or perforation N/A Well pumping test at ~ 5 gallons per of drawdown from static level. Date of completion 11/] 4/77 42 ' feet Cased to 40.5 feet (below) land surface. Finish of well (check one) open end ( ~l'x ). (minute) for 1 hours with 100% WELL LOG Depth in feet from ground surface Give details of formations penetrated, size of material, color and hardness ); 0 2 10 23 32 _TO 2 _TO. 3 TO 1 O _TO. 23 .TO. 32 .TO. 42 .TO. _TO. _TO. .TO. .TO. TO. .TO_ .TO_ .TO. ~smnK s tickuv Crganics Silty Kravel Water gravel Silty gravel Water sand and gravel 2 ' STATE MUNICIPALITY OF ANCHORAC~ OF HEALTH AND ENVIRONME1 !L PROTECTION 264-4720 Date Received: February 13, 1978 ~1: Time i:~P~I #2: Time 93: Time Date ~':/'~ ~;' Date Date Insp Pratt Insp Insp REQUEST FOR APPROVAL OF INDIVIDUAL SEWER AND WATER FACILITIES Lending Institution Request: Alaska Teamster's Federal Credit Union Mailing Address: 1200 Airport Heights Road Phone: Property Owner: James B/Olive Ann Catlin Mailing Address: Post Office Box 543 99567 Phone: 688-2782 Legal Description: Lot 33C Steffes Subdivision Single Family Residence: (x) Number of Bedrooms: Three Multiple Family Residence: ( ) Number of Bedrooms: Well System: Permit ~ Construction Individual Well (x) Community/Public System ( ) Depth of Well 4~ Well Log on File Bacterial Analysis (x~x Sewage Disposal System: On-site System (x) Public Utility Permit # Installed lg77 Installer Septic Tank Size IOOO Manufacturer ( ) Absorption Area Soils Rate ~-- Material Distances: Well to Septic Tank to Absorption Area to Sewer Line Nearest Lot line Absorption Area Nearest Lot Line Page Two ~- Department of Health and Environmental Protection Request for Approval of Individual Sewer and Water Facilities Legal Description: Lot 33C Steffes Subdivision Comments: Affadavit Attached: Approved: ~C ~~ Disapproved: Lettsr Attached: ( ) Date: Department Worksheet: ~a~Selsod snld) i~O~--'ll¥1AI 031JI/~130 ~lOJ /d1303~J · · ~, ' MUNICIPALITY OF ANCHORAC ~ '~ i Department of Health and Environmental Protection /f~!/ 825 L Street, Anchorage, Alaska 99501  / 264-4720 ~ "?~ ~quest for Approval of Individual Sewer and Water Facilities 1. Property Owner: =~ rY)~-S' ~ ~/TJ tP(= Mailing Address: ?' 0 ' ~ ~< ~ Phone: 6 Mailing Address: ~ Phone: Mailihg Address: Phone: o o o Realtor/Agent: Mailing Address: Legal Description: Street Location: Phone: Single Family Residence: Multiple Family Residence: Number of Bedrooms: Number of Bedrooms: Water Supply: *Individual Well K) Public/Community System If Individual Well, well depth ~/ ( ) If Community System, name of system Sewage Disposal System: *~n-site System ~) Public System If On-site System, date of installation: NOV' Iq ~ ~ ( ) *NOTE: A well log is required on ALL wells drilled since 6/~5'. ** If on-site sewer system is over two(2) years old, an adequacy test is required by this department. A fee of $25.00 must accompany each request before processing can be initiated. 3/77 Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www. muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. o5~--~-o5-~-7 1. GENERAL INFORMATION Complete legal description Steffes Lot ~-~C COSA #' Expiration Date: Location (site address) 2~.o39 Helluva Street, Chugiak, AK 99567 Current Property owner(s) Mailing address Lending agency Mailing address Robert Landmesser PO Box 672588, Chugiak, AK 99567 Day phone Day phone Real Estate Agent Barbara Crittenden/Prud Jack White Day phone 2/+2-2227 Mailing Address z66g5 Centerfield Drive, Eagle River AK 99577 Unless otherwise requested, COSA will be held by DSD for pickup. NUMBER OF BEDROOMS: TYPE OF WATER SUPPLY: Individual,Well Individual Water Storage Community Class __ Public Water System Well TYPE OF WASTEWATER DISPOSAL: [] Individual On-site [] Individual Holding Tank [] Community On-site [] Public Sewer The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Pannone Engineering Services, LLC Phone 272-82:L8 Address P.O. Box zoo2~.7, Anchorage, AK 99qzo Engineer's Printed Name Steven R. Pannone, P.E. Date 9/8;x//¢' Engineers Comments: In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MOA DSD Guidelines & Regulations. The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. PES can therefore not provide any warranty for future performance nor give any estimate of how long the system will continue to meet the operational requirements of the MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized nor will it confer any legal right whatsoever. 5. DSD SIGNATURE ~t/'"' Approved for -~ bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory X Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other '~'~°'~/--Original Certificate Date: Municipality of Anchorage DeVelopment Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: A. WELL DATA Well type Private Date completed ~.~.l',~,l~.q?? Total depth z,2 ft. Steffes Lot ~c Parcel ID: osz-[o~;-=.7 Date of test Static water level Well production z~; WATER SAMPLE RESULTS: Coliform /~__.b) colonies/100 mL Arsenic: ~.)~) ug/I B. SEPTIC/HOLDINO T/~IK DATA lank lype/Matedal Sunset/Fiberglass Tank size ~ooo. gal. Foundation cleanout (Y/N) Date of pumping C..I~SORPTION FI£LD DATA If A, B, or C provide PWSID # Well Log (Y/N) Y Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y Cased to ~o.~ ft. Casing height (above ground) =j6 FROM WELL LOG AT INSPECTION x:UaldX q7? el~ol=o', ~. 6 ff. 3.:z ff. g.p.m. 6+ g.p.m. in. Nitrate I-O(~ mg/L Date of sample: Other bacteria ,It,/~--~ colonies/lO0 mL Collected by: Laura Pannone Date installed Number of Compartments _~ Cleanouts (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N/A Pumper JR'S PUMPING Date inStalled Length 8o/~8 ft. Width Total depth 3, ft. Eft. absorption area ~o:1' ft2 Date of adequacy test 8/~o/~o~. Results (Pass/Fail) Fluid depth in absorption field before test DRY in. Elapsed Time: _o min. Final fluid depth DRY in. Any rejuvenation treatment (past 12 mo.) (Y/N & type) Soil rating (g.p.d./~ or ft2/bdrm) ~ ft. Monitoring tube Y PASS System type Deep Trench Gravel below pipe ~.~; ft. Depression over field N For 3 bedrooms Water added~5o gal. New depthDRY in. Absorption rate >=/,5o+ g.p.d. NONE KNOWN If yes, give date LIFT STATION Date installed "Pump on" level at __ in. Datum SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 92' Waived Absorption field on lot 98' Waived Public sewer main N/A Sewer/septic service line 25+ Animal containment areas ~oo+ Manhole/Access (Y/N) High water alarm level at Meets alarm & circuit requirements? On adjacent lots ~.oo+ On adjacent lots ~oo+ Public sewer manhole/cleanout N/A Holding tank N/A Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Absorption field 5+ Surface water ~.oo+ Water main N/A Driveway, parking/vehicle storage Building foundation 5+ Water main N/A Wells on adjacent lots ~oo+ Property line ~o+ Water service line 2=;+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 8,5' Waived Water Service line 25+ Curtain drain NONE KNOWN COMMENTS '4o~ sf absorption area per SRP. Building foundation ~.o+ Surface water ~oo+ Wells on adjacent lots zoo+ 10o+ 25+ in. G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Date Steven R. Pannone~ P.E. I?/// COSA Fee $. Date of Payment Receipt Number (Rev. 11/05) 00'-4 Waiver Fee $ Date of Payment Receipt Number SGS Ref.# I 114128001 Client Name Pannone Eng. Sty. Printed Date/Time 09/07/2011 15:29 Project Name/# Steffes Lot 33C Collected Date/Time 08/28/2011 11:30 Client Sample ID Steffes Lot 33C Received Date/Time 08/29/2011 11:00 Matrix Drinking Water Technical Director Stel~hen C. Ede Sample Remarks: Allowable Prep Analysis Parameter Results LOQ Units Method Container ID Limits Date Date Init Metals by ICP/MS Arsenic 5.00 U 5.00 ug/L EP200.8 C (<10) 08/31/11 09/06/11 NRB Waters Department Total Nitrate/Nitrite-N 1.08 0.100 mg/L SM20 4500NO3-F B (<10) 08/30/11 AYC Microbiology Laboratory E. Coli Total Coliform Negative 1 100mL SM20 9223B A 08/29/11 DLC Negative 1 100mL SM20 9223B A 08/29/11 DLC SEP-?-E011 14:43 FROM:JR'S SEPTIC PUMPING 90?3449821 TO:E?~B~11 P.1/1 JRs Pumping PO Box 773415 Eagle Rive. r, AK 99577 (91)7) 694-6454 i:Billi~g Information Pannone Engineering Po Box100217 Anchorage, AK 99510.0217 (907) 272-8248 Office # [Job Site Information Laura 21039 Helluva Street Chugiak, AK 99567 Job Description: P.O. Number. Terms: Salesmp: Map Book: Cross Streete: Job Comments: 10009 N~ 3O Dawn. Dawn Birchwood Loop Rd Service Agreement Number: 034226 Order Date: 29-Au9-2011 Service Date: 01-Sep-2011 Technician: Mike Tax %: 0 Job Type: Repeat Map Gdd: 27 - - Last Service '10/06/2009' single clean out on tank clean outs ok back flushed 2 times--clean 10009 Additional Location Comments 2 story ranch home Septic is next to porch Diagram; ~ 3Diaaram~2B8 ?',5.hmo II.jla Gallons Planned: 1000 Gal. Actual: Hose Length~ Double Tank: [] ~ Pump System: [] ~ Baffles Outlet: [] ,,, Service Type Qty Price Each Tax? Septic Serv 1000K I $185,00 No NonTaxable Total Estimated Charges; $185.00 Actual Charges: Customer agrees to me terms and aonditions Shown. ]'HIS IS A I~INDING AGREEMENT. Extension Actual $185.00 Taxable Total Tax Total Grand Total $0.00 $0.00 $185.00 - '--I Aooepted by JR~ Pumping .... I:)~te Accepted For your added convenience we accept; Dlccver, Visa and Master Card payments over the phone. AIle~ 30 Days account will be turned over to COLLECTIONS. $30.00 For NSF Checl($ Returned. Municipality of Anchorage Development Services Department Suilding Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onstte (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. o,:[3.-3.o{-17 1. GENERAL INFORMATION Complete legal description Steffes, Lot :~C COSA# Expiration Date: I/~..%//O Location (site address) 2~o¥~ Helluva Street, Chuqiak, AK qq567 Current Property owner(s) Olive Catlin Day phone Mailing address Lending agency 22oc Eureka St.. #3&2, Anchorage, AK qq~o~l Day phone Mailing address Real Estate Agent Doug Van Etten/Keller Williams Day phone 86,{-6549 Mailing Address Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class __ Public Water System Well TYPE OF WASTEWATER DISPOSAL.' [] Individual On-site [] Individual Holding Tank Community On-site [] Public Sewer The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of AJaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for propedies served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of Issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B weIIs or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and lype of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and Inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Pannone Enqineerinq Services, LLC Phone 272-8218 Address P.O. Box '~o2q~z,, Anchors§e, AK qq~;lo Engineer's Printed Name 5teven R, Pannone, P.E. Date ~ ~'/~/'~, Engineers Comments: In conducting an adequacy leSt, l attempt to provide a thorough, conscientious engineering analysis of thc system in accordance with MOA DSD Guidelines & Regulations. The reported results describe the performance of the system under the conditions encountered at thc time of the test, and separation distanceS measured Io readily identifiable features. Thc operational life or alt wells and septic systems depend on the local soil condition, ground water levels that may fluctuate during the year, and the water usage of thc family being served by thc system. ,~+ ,. ~.-_~.~,""'"~ ~.e These conditions are outside the control o f the evaluator of this system. All systems eventually fail and sat~sfactop/test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. PES can therefore not provide any warranty for future performance nor give any estimate of how long the system will continue to racet the operational requirements of the MOA DSD. The content of this report is for the sole benefit of the owner listed above Any rehance upon or use of this report by any other person or party is not authorized nor wdl it confer any legal right whatsoever. 5. DSD SIGNATURE t~ Approved for ~ bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitre, re Advisory ~ X Arsenic Advisory Maintenance Agreements Supplement,al Engineer's Report Other blJo[,~? r Original Certificate Date: Legal Description: A. WELL DATA Well type Private Date completed 3..q.~zJ3.c~77 Total depth ~,3. fl. Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.orglonsite (907) 343-7904 ~l;~ffes Lo~ CERTIFICATE OF ON-SITE SYSTEMS APPROVAL. CHECKLIST Parcel ID:L,~.m -3.m;-3.7 IfA, B, or C provide PWSID #' Sanitary seal (YIN) ~. Cased to ..~o."1 ft. FROM WELL LOG 3.3. 3. fl. g.p.m. Nitrate Date of sample: Number of Compartments ~= Depression over tank (Y/N) IN Pumper IR'~; PUMPING Date of test Static water level Well production WATER SAMPLE RESULTS: Coliform ~:~ .colonies/100 mL Arsenic: ugfl B. SEPTIC/HOLDING TANK DATA Tank Type/Material ~vn~et. JFibereless Tenk size ~.oee gal. Foundation cleanout (Y/N) Y Date of pumping =el6b, oo9 C. ABSORPTION FIELD DATA Date installed 3..~J22h. nT/ Length 8olz8 ft. Well Log (Y/N) Y Wires propedy protected (Y/N) Y Casing height (above ground) '~6 in. AT INSPECTION 3.2 ft. 6* g.p.m. Other bacteda O colonies/100 mL Collected by:. Luke Mattson Date Installed ~.al23[~77 Cleanouts {Y/N) y High water'alarm (Y/N) system type DeePTrench Gravel below pipe 3.."i Soil rating (g.p.d./ff Width ~1 ft. Total depth 3 ft. Eft. absorption area &ot* ft2 Monitoring tube Y Depression over field IN Date of edequac~ test 3.ohl',oon Results (Pass/Fail) PASS For 3 bedrooms Fluid depth in absorption field before test DRY in. Water addedgoo, gal. New depthDRY in. Elapsed Time: _o min. Final fluid depth DRY in. Absorption rate >= MID,' g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN .If yes, give date D. 'LIFT STATION Date installed 'Pump on' level at __in. Datum E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot Absorption field on lot Public sewer main N/A Sewer/septic service line Animal containment areas Manhole/Access (Y/N) High water alarm level at Meets alarm & circuit requirements? On adjacent lots. On adjacent lots ~.oo* Public sewer manhole/cleanout Holding tank N/A Manure/animal excrete storage areas. SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Absorption field ~* Surface water aoo* Water main. Driveway. parking/vehicle storage Building foundation ~;*. Property line Water main NIA Water service line Wells on adjacent lots SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Properly line 8..~' Building foundation Watar Service line ', ~;,, Surface water Curtain drain NONE KNOWN Wells on adjacent lots F. COMMENTS Well to tank/field & lot line waivers attached. */.o:~ sf absoretion area oar SRP. G. ENGINEER'S CERTIFICATION I cerfify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name 5raven R. Pannone. P.E. Waiver Fee $ Date of Payment Receipt Number / o.Fo COSA Fee $ Date of Payment Receipt Number (Rev, 11/05) in. Municip alit3~ o! Anchor age ~.:~ P.O. Box 196650 4700 Elmore Road Anchoraqe, Alaska 99519-6650 · (907) 343-7904 · Fax {907) 343-7997 http:l/www.muni.or.q/Onsite Development Services Department On-Site Water and Wastewater Proqram Department **** VARIANCE/WAIVER REVIEW **** WR//: 090062 HA#:090373 Permit: PID#: 051~-105-17 Legal Description: Steffes Lot 33C Engineer. PES Applicant: Olive Catlin Your request for a waiver of the items listed below has been approved. I. 100 foot well to septic tank separation distance waived to 90 feet, 2. 100 foot well to drainfield separation distance waived to 96 feet, 3. I 0 foot drainfield to property line separation distance waived to 7 feet, 4. 2 foot drainfield cover depth waived to 1.5 feet. This waiver approval applies to the four items listed above only. Any future upgrade to the on- site wastewater disposal system will require all separation distances be met or another approval from this department. Waiver is Granted: X Waiver Is ng~ranted: .n i Date: 1Q/?:~/09 Approved b~//~/) c~/'~ .. ...... .... .... . .... .. ........... ....~.:__...,.~.m.¥.?.?.,:.~.; .... . ..... ....... Rec#: 009447 Amount: $1,050.00 Date Paid: 10115/09 **** VARIANCE/WAIVER REVIEW **** Pannone En§ineerin§ Services LLC Steven R. Pannone, Principal Registered Professional En§ineer E-mail: stevet~oanen~ak.¢gm Oclober22, 2009 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program 4700 S. Bragaw Street Anchorage, Alaska 99519 Subject: Steffes S/D Lot 33C COSA Request/Waiver Requests Ladies and Gentlemen: I am writing to request that a Waiver be granted for this property and that a Certificate of On-site Septic Approval (COSA) be issued for this property. PES conducted an investigation on this lot on October 6, 2009. The well was able to produce in excess of six gallons per minute (6 gpm). The septic system was dry at the start of the test and remained so at the introduction of 900 gallons of clear liquid. This system is operating adequately for a three bedroom system. The system has a few minor code deficiencies that need to be addressed. These deficiencies are the subject of this waiver request. 1. Waiver Request. I request the following~r$: ~ ~"-~x~ a. Well to Septic Tank from 100 fff~t to 90 feet _. _ ,.., ~ ~ t s b. Well to Drain Field, from 100~feet to-9~-~eet etr~'~' r_ ~, lO/~TaT/Oq c. Drain field to Property line, fr~ ' The Septic tank was installed in 1977 and is constructed of fiberglass. It is unlikely that this tank is leaking due to the nature of it construction. A recent water analysis measured the nitrate levels in this well at 1.47 mg/l. The septic tank and drain field are located approximately three feet uphill from the well and a surface contamination is unlikely. The hydraulic gradient is 4.7 degrees towards the well The soils are silty gravels having an application rate of 125 sf per bedroom in 1977 (which equates to about 188 sf/br or 250 sf/br under the current code.) In review of the ADEC Waiver Memorandum the following points are tabulated: Mailing: P.O. Box 102954, Anchorage, Al( 99510-2954 Physical: 11301 Olive Lane, Anchorage, AK 99515 Telephone: {907) 272-8218 FAX: (907) 272-8211 Page 2 of 2 Section Points Water Table (11 fi) 1 Soil Sorbtion (silty Gravel) 3.5 Permeability 2 Water Table Gradient (-5%) 2.0 Horiz. Separation (90ft) 2.9 Total 11.3 points 8-12 Points, Contamination unlikely from bacteria but could be possible from chemicals or vires. The surrounding lots are developed. The existing septic systems are located greater than ten feet from the property lines. Granting this waiver will not affect the operations or availability of the surrounding lots to develop or install an on-site sewer disposal system. 2. Cover over Field: The field was installed with 1.5 feet of cover in 1977 and was approved at that time as installed. It has been in continuous operation since that time and has not had any problems with freezing or back-ups. Currently the field is dry and remained dry during our test. I request that the requirement to have three feet of cover be waived, as placing cover over this system would be extremely difficult and expensive. The proposed waivers will not affect the future development of the surrounding or existing lots nor endanger the health and safety of the public. If you have any questions or concerns, please contact me at 272-8218. Sincerely, Steven R. Pannone, P.E. Owner/Civil Engineer Attachments: Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 11301 Olive Lane, Anchorage, AK 99515 Telephone: (907) 272-8218 FAX: (907) 272-8211 lC~ UT~W PLOT PLAN __ AS BUILT ___X SCALE: 1' - 40' GRID NW 1,~58 Project No. 09-185 Lang &: Associates, inc. (907) 5~-e4?e Registered Land Surveyors (907) 522-4e25 kgtangts~alaska.nat / JclangleOalaska.net 11500 Dar,/I Avenue, Anchorage, Alacka 99515-3049 Phone Irax I hereby certify that I hove surveyed the following de,crtbed properb/: LOT 33C. STE~TES SUBOIV]SION (PLAT No. eT-ISB) Anchorage Recording BI~fdcto Alaska. and that the Improvements clfuated thereon ore wl~ln the praperty lines and do not encroach onto the property adjacent thereto, that no Improvements on the property I/lng adjacent thereto encroach on the surveyed premises and that there are no roadway., tr~nemlsslon lines or other visible eovements on lald properly except aa Indicated hereon. Dated this the~'tr-~ Day of c'~'~c~'ro~,~- ~ 't~<:~'~ , at Anchorage, Alaska It Is Ihs responsibility of the owner to determine the existence of any easements, covenants, or roe~dctlons whleh do not appear on the recorded eubdtvlslon plat.