HomeMy WebLinkAboutSPRING BROOK VISTA #1 BLK 3 LT 7 Municipality of Anchorage Community Development Department Page 1 of 3 On -Site Water & Wastewater Program 4700 Elmore St. - P.O. Box 196650 Anchorage, AK 99519-6650 - http://www.muni.org/onsite - (907)343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP171210 PID Number: 050-091-08 R New E Upgrade Name: RUSSELL & JULIE BOTT ABSORPTION FIELD Address: 0 Deep Trench 17-1 Shallow Trench 0 Bed 0 Mound 12221 E. PRINCE OF PEACE DR., EAGLE RIVER, AK 99577 0 Other Phone: No. of Bedrooms: Soil Rating: Total Depth from original grade: 694-9257 3 1.2 GPD/Sq. Ft. 9.12 (MAX.) LEGAL DESCRIPTION Depth to pipe invert from original grade: Gravel depth beneath pipe: SEE DWG. FL 1 6.0 Ft. Fill added above original grade: Gravel length: Subdivision: Block: Lot: SPRING BROOK VISTA #1 3 7 SEE DWG. 42 Ft. Ft, Township: Range: Section: Gravel width, Beds Number of lines: Distance between lines: 2.5 Ft. F, SEPARATIONDISTANCES Total absorption area: 504 Number of trenches: Dist. between trenches: Septic Absorption Lift Holding Public/Private Tank Field Station Tank Sewer Lines SQ. Ft. Ft. Well PUBLIC PUBLIC 25'+ TANK E Septic 0 S.T.E.P. OHolding 0 Other Manufacturer: G.P.ciry: Surface Water 100'+ 100'+ ANCHORAGETANK 1000 Gal. Lot Line 5'+ 10'+ N/A Material: Number of compartments, STEEL 2 LIFT STATION Foundation 5'+ 10'+ Curtain Drain NONE K NOWN Manufacturer ca Y: Gal. Remarks: OLD SEPTIC TANK ABANDONED PER UPC PER CONTRACTOR. 'Pump on'level at: High water alarm at NEW DRAINFEILD IS 20'+ TO 40% SLOPE. WAIVER GRANTED. SEE 1:2!:] Electrical Inspections performed by: WAIVER #OSV171079. PIPE MATERIAL House to tank D3034 Tank to D3034 drainfield Installer NORTHERN EXCAVATION Drainfield D3034 CO/IVIT D3034 Inspector G E G, Ltd. BENCH MARK (Assumed elevation) 106.25 Ft. Inspection Location and Description: Dates: 1st 811812017 2nd 8118/2017 3rd - 4th - BACK (GARAGE) DOOR THRESHOLD Community Development Department Approval ENGINEER'S SEAL Conditional approval: Date: # 0 149 —4--A 0 .... ..... . ... . .. ..... ..... .0 0 . .............. ......... i 0 h * 0- r -Garness JCE-7953 # Approved: Date: .............. 444P op- "ROFESS\ q,�\ LICENSE #AECC884 Inspection Report _1-1-12,doc PERMIT NUMBER: PARCEL ID NUMBER: OSP171210 ECO `IN 050-091-08 4J / 4 co ^ / f NEW DRAINFI / /KEY BOX ' �.._ :.•.-� ..: : r PHYSICALLY DRIVEWAY.;' :;" •, `.'''• VERIFIED A LOCATION r . / / EXISTING 3 BEDROOM / HOUSE APPROXIMATE WATER LINE. CONTRACTOR VERIFIED WATER LINE LOCATION IN CRAWLSPACE DURING CONSTRUCTION. A B FCO 19.0 33.6 STI 24.2 42.5 ST2 30.0 44.8 DBL1 31.9 46.0 DBL2 32.6 46.3 BR 36.6 45.6 C01 43.6 52.4 MT1 43.5 1 51.8 CO2 52.9 1 86.8 MT2 52.5 T 86.6 -APPROXIMATE LOCATION OF 1997 TEST HOLE BY LOUIS A. BUTEW BULL RUN (BR) VALVE NEW 1000 GALLON SEPTIC TANK 9 Ltd ti GME & ENVIRONMENTAL ENGINEERS _ �•- 3701 E TUDOR ROAD, SUITE 101 ` ANCHORAGE, AK 99507 - PHONE (907) 337.6179 ` FAX (907) 338-3246' WEBSITE w ,garner engineeringmm PREPARED FOR: RUSSELL & JULIE BOTT PHONE NUMBER: 694-9257 PROJECT/LEGAL DESCRIPTION: SPRING BROOK VISTA S/D #1; BLOCK 3, LOT 7 TYPE OF WORK: �. RECORD DRAWING OF SEPTIC SYSTEM UPGRADE PAGE NUMBER: 20F3 DRAWN BY: J.L.M. DATE: 8/24/2017 DRAINFIELD lq� ®*��ILcliI; 414 ...`.....�r a .:: "'4 .......... 0 A.acness w 0 0��E-,953 LICENSE44411S��"� ®� #AECC884 / -7 -- PERMIT NUMBER: PARCEL ID NUMBER: MIT UMB 0 OS SP171210 RECORD DRAWING 050-091-08 FINAL GRADE = 101.33-102.05 STI ST2 TOP OF TANK 2" OF INSULATION TOP OF TANK AT INLET = 97,34 PER CONTRACTOR AT OUTLET = 9732 NEW 1000 GALLON INVERT OF BUNG SEPTIC TANK AT INLET 96 73—/ (RATED FOR \—INVERT OF BUNG 10' BURIAL) AT OUTLET = 96.48 FINAL GRADE MT1 C01 99.82-10.0-6-4 MT2 11 CO2 ORIGINAL GRADE LOUIS BUTERA, P.E. @ HIGHEST TEST HOLE POINT= 99.46 2" INSULATION - PER CONTRACTOR FILTER FABRIC INVERT OF PIPE 9634 BOTTOM OF TRENCH = 90.34 RELAT�VE ELEVAT�ON OF GROUNDWATER ON 4/2/1997 PER LOUIS BUTERA, P.E 83.96 RELAT VE ELEVAT ON OF BOTTOM OF TEST HOLE PER LOUIS BUTERA, P.E = 82.46 A lq��swlakilak S VA 'A AV ARNESS ENG INEERIN(3 G"ROUP, Ltd .... 00 ---CIVIL& ENVIRONMENTAL ENGINEERS 0 IT .. . ............ 3701 E. TUDOR ROAD, SUITE 101 -ANCHORAGE, AK 99507 -PHONE (907) 337-6179 -FAX (907) 338-3246 WEBSITE: �.gamessengineedng.com 10 .......... . � .. ............. ........ PREPARED FOR: HONE NUMBER: PAGE NUMBER: 0 ko-- a ess 4Z Ar RUSSELL & JULIE BOTT 694-9257 3 OF 3 E-7951 AV' PROJECT/LEGAL DESCRIPTION: DRAWN BY: SPRING BROOK VISTA SID #1; BLOCK 3, LOT 7 J.L.M. .. ................ 4s, TYPE OF WORK: DATE: oro,411411 E LICENSE ya 1%k 1111L s RECORD DRAWING OF SEPTIC SYSTEM UPGRADE 8/28/2017 1 #AECC884 MUNICIPALITY OF ANCHORAGE On-Site Water &Wastewater Program .s.• � .�� PO Box 196650 4700 Elmore Road Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 http.//www.muni.orgionsite 10160,- I <•partinc•nt On-Site Wastewater Disposal System Permit Permit Number: OSP171210 Effective Date: 8/8/2017 Work Type: Septic Upgrade Expiration Date: 8/8/2018 Tax Code Number: 05009108000 Site Legal Address: SPRING BROOK VISTA#1 BLK 3 LT 7 G:0252 Site Mailing Address: 12221 E PRINCE OF PEACE DR, Eagle River Owner: BOTT RUSSELL D & JULIE I Lot Size in Sq Ft: 30489 Design Engineer: GARNESS ENGINEERING GROUP LTD Total Bedrooms: 3 This permit is for the construction of: 0 Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72)and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: 4 Date: $ 7 Issued By: 1.L/X' 1.'. �RJvur Date: e 8 , 0 = Municipaily ofAnchoira ue116 P.O. Box 196650 • 4700 Elmore Road Anchorage, Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997 http://www.muni.orq/Onsite Development Services Division On-Site Water and Wastewater Program **** VARIANCE/WAIVER REVIEW **** Waiver#: OSV171079 COSA#: Permit#: OSP171210 PID#: 050-091-08 Legal Description: Spring Brook Vista#1 Block 3 Lot 7 Engineer: Garness Engineering Group Applicant: Russ Bott Your request for a waiver of the required 50 feet horizontal separation from the absorption field to the excessive slope has been approved. The approved separation distance is 20.0 feet. See engineers waiver request and profile drawing for justification. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. ❑ Notarized letter(s) of nonobjection have been received from the owner(s) of the affected adjacent property. 11 Adjacent properties are not affected by this waiver. Waiver is Granted: X Waiver is not Granted: Date: 6V/old T 7 Approved by: P...Lkt ameel Name of Reviewer **** VARIANCE/WAIVER REVIEW *'k'k* MUNICIPALITY OF ANCHORAGE Community Development Department i- / Ph. 7904y- Development Services 7 : 9 -343-79 �p On-Site Water & Wastewater Program 0_ AUS i h LL11 " Mayor Dan Sullivan ti �6 'y On-Site Sewer/Well Permit Application c5A For A Single Family Dwelling 01 6 g L Parcel I.D. 050-091-08 Property owner(s) RUSS BOTT Day phone 694-9257 Mailing address 12221 E. PRINCE OF PEACE*EAGLE RIVER,AK 99577 Site address 12221 E PRINCE OF PEACE*EAGLE RIVER,AK 99577 Legal description (Sub'd, Block & Lot) SPRING BROOK VISTA#1, BLOCK 3, LOT 7 Legal description (Township, Section & Range) Lot Size Sq.Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DEWELLING: (®all that apply) Initial ❑ Single Family (SF) ix Absorption Field ® (w/wo ADU) Septic Tank ® Upgrade Duplex (D) ❑ Renewal ❑ Holding Tank ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE!WAIVER REQUEST FOR: DRAINFIELD TO SLOPES>25% Distance: 20 FOOT I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. (Signature of property owner or authorized agent) Permit/Rush Fees: 5 401 Waiver Fees: Date of Payment: gl ti f('i Date of Payment: . Receipt Number: D 0x 61 6 Receipt Number: 01 B 3aS-% Permit No. O5 PI \ 1 210 Waiver No. DSV I 1 b1 CI (Rev.01111) 0 t' QuaniCs GARNESS ENGINEERING GROUP, Ltd CIVIL&ENVIRONMENTAL ENGINEERS Qealer August 8, 2017 Municipality of Anchorage Development Service Department On-Site Water&Wastewater Program 4700 Elmore Road Anchorage, AK 99507 Ref: Proposed Septic System Upgrade for Spring Brook Vista #1; Block 3, Lot 7 To whom it may concern: The existing 3 bedroom house is served by a private septic and public water system. The drainfield is in a state of failure and needs to be upgraded. We are proposing to install a new 1000 gallon septic tank and deep trench type drainfield. We are also proposing to utilize the existing 1997 T.H. by Louis A. Butera, P.E. (attached) and the proposed drainfield is designed within its 30 foot radius. Comments regarding the design are summarized as follows: 1. SOILS: See the attached 1997 logs by Louis A. Butera, P.E. which shows the soil classification, groundwater monitoring, and the percolation test results. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: There are no surface water concerns. 4. TOPOGRAPHY AND WAIVERS: As can be seen on the attached topography drawing, the average topography around the proposed drainfield is 20-25%. However, there are slopes greater than 25% less than 50 feet from the proposed drainfield. Therefore, we are requesting that your department issue a variance from the required separation distance of 50 feet to slopes greater than 25 feet down to 20 feet. As can be seen on the attached profile drawing, a 25% line drawn at 2 feet above the top of rock does not intersect within 50 feet of the existing grade. We are unaware of any adverse impacts this installation or waiver would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your assistance. - ely - -re - . �. - �-.E., M.S. Presii t 3701 East Tudor Road,Suite 101 *Anchorage,Alaska 99507-1259 Phone: (907)337-6179 Fax: (907)338-3246*Website: www.gamessengineering.com W EE O W 0 Q W d SPRING BROOK VISTA#1; BLOCK 1,LOT 5 Al 0 L11 SERVED BY U AW�MJ WATER Er- a. SERVED BY AWWU WATER SPRING BROOK VISTA#1; BLOCK 1,LOT6-A1 Q� �Qli SPRING BROOK VISTA#1; BLOCK 3,LOT 6 SERVED BY <(� �� AVVWU WATER max.• SERVED BY SPRING BROOK VISTA#1; :1004-..• 4- BLOCK AWWU WATER BLOCK 1,LOT 7 �Q COULD NOT PHYSICALLY \ LOCATE WELL;DRAINFIELD IS GREATER THAN 100'FROM THE NORTHWEST LOT CORNER . i I /' � SPRING BROOK VISTA#1; �i L�' BLOCK 5,LOT 5 i � CJS A SPRING BROOK VISTA#1; \� BLOCK 3,LOT 8 SPRING BROOK VISTA#1; G SERVED BY BLOCK 5,LOT 4 AVNMJ WATER • �� '4 / / N. 0 /� -- \\ ��� \\ 100' 1 Q- I ApPRO s1US IGJQ SPRING BROOK VISTA#1;/ I WELL \ I BLOCK 5,LOT 3 . E.A(20 N ppP • '.kus I / \\ \NE1-1-'. I / \ // SCALE: 1 \\ i 1 \ /' 1"=100' GARNESS ENGINEERING GROUP, Ltd = *` .'1. - '•* • CIVIL&ENVIRONMENTAL ENGINEERS • ,�� 0 3701 E.TUDOR ROAD,SUITE 101'ANCHORAGE.AK 99507'PHONE(907)337-6179'FAX(907)338-3246•WEBSITE www ♦ .garnessengineenrg.com •, • , PREPARED FOR: PHONE NUMBER: PAGE NUMBER: ♦ ' : 'I y •:�Ga ess J W IN RUSS BOTT 694-9257 1 OF 3 ♦�J,'••• rC 79 '•_� PROJECT/LEGAL DESCRIPTION: DRAWN BY: 9 i 9 • SPRING BROOK VISTA#1; BLOCK 3, LOT 7 L.K.B. ♦1 "•,''•••••••.....•••`.. .,4. • TYPE OF WORK: DATE: LICENSE ,1�1v„S`lhlb4 SITE PLAN 7/31/2017 #AECC884 K" 7 / / \\ DESIGN CRITERIA: GEG,Ltd.HAS A 8 PAGE SPECIFICATION LETTER THAT PERTAINS TO THIS DESIGN.TO NOTE:THE CONTRACTOR NUMBER OF BEDROOMS:3 OBTAIN A COPY OF THE LETTER CONTACT GALLONS PER DAY(GPD):450 GEG.BY PROCEEDING FORWARD WITH THIS SHALL HAVE THE NORTH & PERCOLATION RATE/S:*2.3 MIN/INCH INSTALLATION,THE ENGINEER,WELL DRILLER, EAST LOT LINES FLAGGED BY A PROPOSED APPLICATION RATE:1.2 CONTRACTOR AND PROPERTY OWNER AGREE REGISTERED LAND SURVEYOR MINIMUM DRAINFIELD SQ.FT.:375 FT2 THAT THEY HAVE READ THESE PRIOR TO CONSTRUCTION. `PER LOUIS A.BUTERA T.H.IN MOA RECORDS SPECIFICATIONS AND AGREE TO ACCEPT THE TERMS AND CONDITIONS OUTLINED. DRAINFIELD DESIGN: MAXIMUM DEPTH: 9.5 FEET / !/. PROPOSED DRAINFIELD WIDTH:2.5 FEET `, LENGTH:40 FEET /. // EFFECTIVE:6 FEET Q / � EXISTING DRAINFIELD TO REMAIN IN ACTUAL SQ.FT.:480 FT' �•� / PLACE FOR FUTURE USE / v C.F / / �P 4` /// S��O ♦ �Q co���// ' /. APPROXIMATE LOCATION OF 1997 / C• • . 2P/�ESTHOLE BY LOUIS A.BUTERA,P.E. APPROXIMATE / /'O 44P/ M k ` '- LOCATION OF KEYBOX / `V ' PER LOUIS A.BUTERA, �� ,`� // x\`1`10 PLS 11-2-98 SURVEY / /}\,` ‘,......,/, / �`�� 35% 5%.3,,... ♦ `C // 1`��;: SPRING BROOK VISTA#1;BLOCK 3,LOT 6 / �Q / 11�� SERVED BY AWWU WATER ♦ ° M • P :/. • D FD / ° �. G • APPROXIMATE LOCATION OF TOP OF TOE; ° SLOPES SHOT IN WITH CLINOMETER / • IDRIVEWAY1 d• �� / / • • �� 12k FE / /1 °. ., ♦ A./ .a ` 55% / / EXISTING 1000 GALLON SEPTIC TANK TO BE DECOMMISSIONED PER UPC ♦ PROPOSED 1000 GALLON STEEL SEPTIC TANK; EXISTING 3 INSTALL DOUBLE CLEANOUTS AFTER THE TANK BEDROOM HOUSE *4 INSTALL FCO IF ONE IS NOT PRESENT j%/././ / /Z,// / // / . / // „`0/ PRIOR TO INSTALLATION OF THE \ SEPTIC SYSTEM;THE WATER // SERVICE LINE IS TO BE // PROFESSIONALLY LOCATED. /// �a4. / 5� \, // G4P `\� / •\� // �.�G // a� SCALE: SPRING BROOK VISTA#1;BLOCK 3,LOT 8 / / 1"=40' SERVED BY AWWU WATER ....4\\\ ' 1111 GARNESS ENGINEERING GROUP, Ltd ; SCALE 1 " = 10' EXISTING GRADE CO MT 25%SLOPE AT 2 FEET ABOVE TOP OF ROCK(DOES NOT INTERSECT) 10% 40% 9.5 FEET 6 FEET 25% 22% -.-20 FOOT WAIVER REQUEST oF Aqs,157 1;7i , Ltd ;i GARNESS ENGINEERING GROUP : 4. ,..; . • CIVIL&ENVIRONMENTAL ENGINEERS 37D1 E TUDOR ROAD,SUITE 101'ANCHORAGE.AK 99507'PHONE(907)3378179'FAX(907)336-3246•WEBSITE.wwwgamessengneerng.corn PREPARED FOR: PHONE NUMBER: PAGE NUMBER: RUSS BOTT (907) 694-9257 3 OF 3 �j�', y Ass LEGAL DESCRIPTION: DRAWN BY: • .r C 79 r� SPRING BROOK VISTA#1; BLOCK 3, LOT 7 D.J.G. •�j FO�O� Z,•"' TYPE OF WORK: DATE 4444 RO ES":4 PROFILE DRAWING FOR SLOPE WAIVER 8/1/2017 J • ■y •a.N - ••• .. ,.-t1.1:"'' Municipality of Anchorage 1' -t .1+ DEPARTMENT OF HEALTH & HUMAN SERVICES .M � •• N• 825 "L" Street, Anchorage, Alaska 99502-0650 r0° Louis A. gutarn w �,+. t:g-6736 .�4r ,40 SOILS LOG — PERCOLATION TEST 4�� '+•V iii •''•"`� PERFORMED FOR: !/\.yJJ ": -- DATE PERFORMED: 3 -/3 -S•2 SPie7.v0.r iepuor ,/rP.R sz/ LEGAL DESCRIPTION. La f 7 4'/4- J Township, Range,Section: SLOPE SITE PLAN 1 2 1111111111. N 3 -off , 4 G/ 5 ' SrNs�j G... w/t.it I 111` lyleif. .,,r-e_ fr 6 - 8i w.,,, 7 4 $ O 9 )9- t0 , ` GROUND ENCOUNTERED?WATER YFI 11 O IF YES,AT WHAT L 12 DEPTH? /6'/ P ter. E 13 ‘? Oeplh to Waler Atter Monitoring? /5:6 gale: `1-a--77 14 •- p Reading Data Gross Net Depth to Net 15 Time Time Water Drop `J 7'-.L v,." 16 io., ,no' 7 %. 6 a V 4//g.' ? r 2; 70 17 .2 : Yo /o .n..,; 7 /is r 18 G 04, '2'SI /0 7 '-6 -(7;4yJ44" 19 20 PERCOLATION RATE (minutesnncht PERC HOLE DIAMETER g. TEST RUN BETWEEN 2 FT AND E FT COMMENTS PERFORMED BY: ........ c.___t CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: "a 5? 72-008(Rev.4/85) 1 V IV1 i nr --/--__-.\ '' ' ''''''•.-\ 116 1°1 V • --...„ \ IS.t , t 0hi ' _- - /:alp• ' tp�. 0 • \ \ ,\ 1'0 NN La \ \�'� S `• 6°' al � . .. - Io. "/ 46 ` Z z /0/ `.."1/4\:, .. / II- ,/ 4 ' / k\\ / 4 CZ;\ . / I 0 T 7 61 /fil ..,. Aie ...\, N4 ASBUILT SEWARD & ASSOCIATES LAND SURVEYING 694-082q I HEREBY CERTIFY THAT I HAVE SURVEYED THE SCALE'd_ / ,�og,�,‘% FOLLOWING DESCRIBED PROPERTY: _ _mmoatelommemmame_ .„,„-•. .., aF A L ��4 sa.Qlti, ')v -f /,,U/.--"/O,/zp7-z,'-.7- DATE- p � •- ' �i' t. AND THAT NO ENCROACHMENTS EXItT EXCEPT AS ��/� 4V& INDICATED. IT IS THE RESPONSIBILITY OF THE ` .1:..-'' ' OWNER TO DETERMINE THE EXISTENCE OF ANY GRID: i EASEMENTS, COVENANTS, OR RESTRICTIONS ./2S2. 0l� � WHICH DO NOT APPEAR ON THE RECORDED SUBDI- --- 0. Duane Mark Seward k 0 VISION PLAT. UNDER NO CIRCUMSTANCES SHOULD FB: , t �.•. 7.:riy." y ANY DATA HEREON BE USED FOR CONSTRUCTION _ may'�7 •t `a`�•,- �54+* • OF FENCE LINES, OR FOR ESTABLISHING BOUND "' ' ' 'i '� �ft.'r- .,...0 4- s‘, ARY LINES. DI`2AWN= ��,,,.a Municipality of Anchorage Page DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 . On-Site Wastewater Disposal System and/or Well Inspection Report Name:Wastewater System: ~ New D Upgrade Address: ~ /o N , Phone: ~X'~ IN°'°fBedr~ms: ~ Deep Trench ~ Shallow Trench ~Bed ~Mound ~Other LE GAL D ESC R IPTI O N S°il Raling: /, ~ GPD/Sq. Ft. Total Depth from original grade:~,~ Lot: Block: Subdivision: Depth to pipe botlom from onginal grade: Gravel depth beneath p~pe Township: Range: Section: Fill added above original grade: Gravel length: WELL: P~/'~ ~ New ~ Upgrade O~,e~w~dth: Number of lines: 0[stancebelweenlines: Classification (Private, A,B,C): / Total Depth: ¢Cased To: Total absorption area: Pipe material: Driller: / Date D Static Water Level: Installer: Date installed: Yield: .~ PumpSetat: ~ Casing Height Above Grou;;: TANK SEPARATION DISTANCES ms~i~ a Holding ~ S.T.E.P. TO SepllC Absomllon LiII Holding Public/Private ~anufacturer: Capacity in gaJJo~s: From Tank Field Station Tank Sewer Lines ~ ~ ~ ~ Material: Number of Compartments: Surf~c. , W/4 LIFT STATIO N Water ¢/~ ¢/oo ' ~__ ~ LineL°t %¢ / / ~ f ~ % I Size in gallons:%~ufacturer:% "Pump on" level at: ~ump off" level at: H~ter alarm at: Foundation /~ ~ 5~ ¢ ~1% % Curtain ~ ~ ~ Pump Make & Model Electrical~tions performed by: Drain Remarks: BENCH MARK Location and Description:  Assumed Elevation: Inspections performed by: ~,E,~, Dates: 1st s-/¢/¢~ ¢~,~~~~~ Department of Health and Human Services approval '~.,, *'~'~;,%,;;: Reviewed and approved by: Date: ~ 72-013 (Rev. 9/91) MOA 25 Permit No, -- Page 2 of 2 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P,O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 545-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Legal Description: Spring Brook Vista .1 L7 BIk 3 PID No.: -- ! 000 GAL 5fi, PT C TANr. Garage / LOT 6 SEPTIC PIPE o YX32' SWING TIES A-C = 26,3' B-C = 36.5' A-D -- 80.1' B-D = 67.7' o o SEPTIC PIPES LOT 8 ELEVATIDNS (NOT TO SCALE) ORIGINAL GROUND LEVEL AT: 93.7~ TANK ~3,5~90.8 ~ ~90.8 ~@4.8 ~ - TEST HOLE · - MONITOR TUBE o SEWER CLEANOUT + KEYBOX -- LEACHFIELD EASEMENT WATERLINE SCALE 1"=50' 8/19/97 r ENGINEER'S SEAL ~^R^~E C0NC. S,,,~ / / ~ ~P." 49 m ~. "..~, / '~'~':t~~ ......... :... /~ ~b; N2<~ .......... , ~== ~ "~ /~$". ~oui~ A. eut~,o ..'~ PAGE 1 OF 1 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALAStCA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW970085 DESIGN ENGINEER:EAGLE RIVER ENGINEERING SERVICES OWNER NAME:RUSSEL BOTT OWNER ADDRESS:1830 E.PARKS HWY. #539 WASILLA, AK. 99564 PARCEL ID:05009108 DATE ISSUED: 5/07/97 EXPIRATION DATE: 5/07/98 LEGAL DESCRIPTION: SPRING BROOK VISTA #1 BLK 3 LT 7 LOT SIZE: 30489 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: THE ATTACHED APPROVED DESIGN. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18A_AC72) AND DRINKING WATER REGULATIONS (18AAC80). THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT} FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABsoRPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: TOTAL DEPTH OF TRENCH MUST NOT EXCEED 9 FT. BELOW ORIGINAL GRADE. RECEIVED BY: A ~ ~ J [ ~ ISSUED BY: ~:"' ~ J ! DATE: '7 ~ Ea le River En ineerin ervices Louis Butera, P.E. P.O. Box 773294 (907) 694-5195 tel ]~agle River, AK 99577-3294 (907) 69'[-3297 fax March 17, 1997 Jim Cross, P.E. Manager, On-Site Services Municipality of Anchorage P.O. Box 196650 Anchorage, AK 99519 Re: Spring Brook Vista #1 Lot 7, Block 3 Narrative & Permit Application Dear Mr. Cross: The proposed septic system will have very limited impact following reasons: 1. 2. 3. 4. If you have any questions please call our office at 694-5195. on adjacent properties for the The surrounding lots are large, allowing sufficient room for septic sites. Immediate neighboring septic systems are all +30' distance. Reserve space is adequate, due to absorption capacity, and public water supply. Drainage will not be affected and is not a major consideration in our design. Sincerely, Louis Butera, P.E. \ 1997\97-009A-NAR.DOC ] a le River En ineerin Services Louis Butera, P.E. P.O. Box 773294 (907) 694-5195 tel Eagle l~iver, AK 99577-B29~ (907) 69~-B297 fax LEGAL: A. 1. 2. 3. 4. 5. SPECIFICATIONS FOR ON-SITE SEPTIC SYSTEM Spring Brook Vista #1 Lot 7, Block 3 03/17/97 GENERAL The septic plan is for a single family residence only. The drawing and or site plan shall be a part of this specification. All materials and workmanship shall meet the Anchorage Department of Health requirements. All soil tests are advisory to the design and are to be verified or modified itl the field by the engineer. All excavations and depths are advisory and are to be verified in the field by the contractor to meet Municipality of Anchorage requirements. 6. It is the responsibility of the owner to obtain all necessary permits or easements and to locate any adjacent multi-family ~vells. 7. The excavation is to be exactly in the area shown on the site plan, any deviation requires engineer approval. 8. it is always recommended that a surveyor locate the nearest lot line position and the location of any easements. 9. Any remaining open test hole excavations shall be filled. B. SEPTIC TANK 1. Septic tank shall be a minimum of 1,000 gallons, and of MOA approved design. C. TRENCH 1. The trench is to follow the natural land contour to maintain uniform total depth of the trench bottom. 2. The bottom of the trench shall be level, plus or minus 1.5". 3. The total depth of the trench excavation is not to exceed 9' at any point. 4. The effluent line within the trench shall be laid level wittfin 0.03'. 5. The trench gravel is to be covered with typar fabric material. 6. Soil or combination of soil and extruded board insulation to a depth of 3' or equivalent is to be placed over the leachfield. 7. The area over the trench is to be finish graded to prevent ponding of surface water runoff. 8. The septic tank and leachfield must not be closet' than 100' to any existing private well, 150' to any Class "C" well, or 200 feet to any community well. RECOMMENDED LEACHFIELD DIMENSIONS: TOTAL DEPTH = 9' GRAVEL DEPTH = 6' under pipe, 2" over pipe TRENCH LENGTH = 32' TRENCH WIDTH -- 3' SO1L RATING = 1.2 GPD/SF BEDROOM CAPACITY = 3 SEPTIC TANK = 1,000 gallons minimum Twenty-four (24) hours notice required for all inspections. \1997\97-009a-spc.doc rr6~/~ / "X LOT 6 / .q,/ ~ .... T-~.4~-m. ~,x~, T~NC, . o - SEWER CL~NOUT PUBLIC WATER - NO WELLS / EASEMENT NO SURFACE WATER NO KNOWN CURTAIN DRAINS / PROPOSED LEACHFIELD SEPTIC SITE PLAN LEGAL: SPRING BROOK VISTA ~1 LOT 7 BLK 3 ' CONTRACTOR: N/A ~:~9TH~., EAGLE RIVER ENGINEERING ~ERV]CES P.O. Box 773294 EAGLE RIVER, AK. 99577 (~o7) ss4-s~s5 FAX: (SO7) SS4-SZ97 EAGLE RIVER ENGINEERING SERVICES P.O. Box 773294 Eagle River, Alaska 99577 (907) 694-5195 ERES Project No.: 97-009 Calculated By: LB Date: 5/7/97 Legal: SPRING BROOK VISTA#1 LOT 7 BLK 3 Single Family 3 Bedroom Dwelling TEST HOLE Deep Trench Subsurface Wastewater Disposal Field Water use at 150 gallons per bedroom = 450 gallons Percolation rate = 2.3 minutes per inch Wastewater application rate = 1.2 gallons per day per square foot Required absorption area = 375 square feet Trench width (W) = 3 feet Gravel depth (D) = 6 feet Required length = Required absorption area / 2 / D Required length = 375 / 2 Required length = 32 feet Total Excavation Depth = 9.0 feet / 6 77 SINGLE FAMILY ON-SITE WORKSHEET ERES PROJECT NUMBER: g7-00g CALCULATED BY: LEGAL DESCRIPTION: SPRING BROOKVISTA #1 LOT 7 BLK3 NUMBER OF BEDROOMS: WATER USE PER BEDROOM: PERCOLATION RATE: DEPTH TO GROUNDWATER: DEPTH TO IMPERMEABLE LAYER: ANTICIPATED DEPTH OF COVER: MOUND OR BED SYSTEM WASTEWATER APPLICATION RATE: ABSORPTION ARE;A REQUIREMENT: MINIMUM BED LENGTH 12 FEET WIDE BED 15 FEET WIDE BED TRENCH SYSTEM WASTEWATER APPLICATION RATE: ABSORPTION AREA REQUIREMENT: SHALLOW TRENCH OPTIONS 5 FEET WIDE TRENCH LB 3 150 GALLONS 2.3 MINUTES PER INCH 15,5 FEEl' 16 FEET USABLE SOIL STRATA 3 FEET TOTAL USABLE DEPTH: USABLE SOIL STRATA DEPTH: 0.8 GAL/SQ.FT 563 SQ.FT 10 7 47 FEET 38 FEET 1.2 GAL/SQ.FT 375 SQ.FT DEEP TRENCH OPTIONS 3 FEET WIDE TRENCH EFFECTIVE REQUIRED TRENCH EFFECTIVE REQUIRED TRENCH DEPTH (FT) ENGTH (FT) DEPTH (FT) ENGTH (FT) 1 66 4 47 2 53 4.5 42 2.5 48 5 38 3 44 5.5 34 3,5 4O 6 31 4 38 7 27 8 NA 9 NA D (B=BED, S=SHALLOWTRENCH & D=DEEP TRENCH) 6 FEET 3 FEET 32 FEET DESIGN SPECIFICS FIELD SYSTEM: GRAVEL DEPTH: TRENCH OR BED WIDTH: LENGTH: TOTAL EXCAVATION DEPTH: 9.0 FEET PERFORMED FOR: LEGAL DESCRIPTION: Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST DATE PERFORMED: ~ -/-~ - ~" ? Township, Range, Section: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19- 20- COMMENTS SLOPE WAS GROUND WATER ENCOUNTERED? ,,(//~S IF YES, AT WHAT DEPTH? Oeplh Io Waler Afl0r Monitoring? ,),~" SITE PLAN Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE ,~-' ~ (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN '~ FT AND ~' FT PERFORMED BY: ,,~-~,~-J'*' I CERTIFY THAT THIS TEST WAS PERFORMED IN 2 ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDEL[NES IN EFFECT ON THiS DATE. DATE: 72-008 (Rev. 4/85) ' Municipality of Anchorage • °`_ °° { On-Site Water&Wastewater Program \ll (907)343-7904 Y. CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 050-091-08 Expiration Date: 1 ? �� 1. GENERAL INFORMATION Complete legal description SPRING BROOK VISTA SID#1; BLOCK 3,LOT 7 Location (site address) 12221 E. PRINCE OF PEACE DRIVE, EAGLE RIVER,AK 99577 Current Property owner(s) RUSSELL AND JULIE BOTT Day phone 694-9257 Mailing address 12221 E. PRINCE OF PEACE DRIVE, EAGLE RIVER,AK 99577 Real Estate Agent Day phone 2. TYPE OF DWELLING: • Single Family (w/wo ADU) ❑ Duplex E Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual On-site Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System U Public Sewer ❑ WaiverNariance request for N/A Distance: Received by: Date: f /(0 71-7 COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee $ t(i Waiver Fee$ Date of Payment 1/ $1 `!"t Date of Payment Receipt Number 0Receipt Number COSA# 6 -3C-1e7-134C19 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, i verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. /further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179 Address 3701 E. TUDOR ROAD, SUITE 101 'ANCHORAGE,AK,99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date 143 )240, Engineers Comments: In conducting this evaluation,GEG provided an engineering evaluation of the well andlor septic system in accordance with the #41�11C t%k M 1 guidelines and regulations established by the Municipality of Anchorage and industry practices. OF The reported results describe the �4< condition of the systemic on the date/s of the evaluation.Separation distances were measured to readily identifiable features. ♦� Hidden defects or encroachments may exist that were not identified during the evaluation.The operational life of all wells and septic �r •"•,•,,,•••i �j systems depend on a variety of variables including,but not limited to,soil conditions,groundwater levels(that may fluctuate during �� the year),quality ofconstnrdion(materials and workmanship),and the water usage of the family utilizing the systernrs.These '411 A / '\ •;* ' conditions can vary,and are outside the control of GEG.Satisfactory test results do not guarantee future performance of the �/ (Y/ system/s;therefore,GEG makes no warranty(express or implied)regarding the future performance of the well or septic system. i • GEG makes no representation whether an alternative well or septic system can be installed on the property in the event either of the f r 11r� � M current systems fail.The content of this report is for the sole benefit of the personlparty who retained GEG.Reliance upon the •:r f '' tr~ • r^ 4�Je ,ey A. Garness : Lia information provided in this report by any other person or party,including but not limited to subsequent property purchasers,is not � ,41" authorized.In short,GEG disavows any legal duty to anyone other than the person/party who paid for this report. �* 172C E- 79531,1 <(/)),,,_••••., (6!2-43 .(, '''� ': 6. DSO SIGNATURE ��� '°ROFESSIA�4_� LICENSE ,Mti�%is*** 11 ttAECCBB4 System#1 Approved for bedrooms. System#2 Approved for bedrooms. Le Disapproved. r � ri_Y i S i i-E WATER AND ¶. Conditional approval for bedrooms, with the following:lstipuiatG sifvn -E`: C • B 1111111MIEWOriginal Certificate Date: c ' S —I 7 The Municipality or Anchorage Develop,emt Services Division(DSD)issues Certificates of On-Site Systems Approval(COSA)based only upon the represenalations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTCHMENTS: COSA Checklist Nitrate Advisory • Septic System Advisory Arsenic Advisory Well Flow Advisory Other lRov 1N17/171 If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: SPRING BROOK VISTA SID#1; BLOCK 3, LOT 7 Parcel ID: 050-091-08 A. WELL DATA SERVED BY PUBLIC WATER Wel ••e If A, B, or C provide PWSID# Well Log (YIN) Date complete. Sanitary seal (Y/N) Wires properly protect-c /N) Total depth ft. Cased to ft. Casing hei.• above ground) in. FROM WEL •G NSPECTION Date of test Static water level . ft. Well production g.p.m. g.p.m. WATER SAMPLE RES : Coliform colonies/100 ml. Nitrate mg./L. Collected by: A lc: ug./L. Date of sample: B. SEPTIC/HOLDING TANK DATA Tank Type/Material STEEL Date installed 8/18/2017 Tank size 1000 gal. Number of Compartments 2 Cleanouts (Y/N) YES Foundation cleanout(Y/N) YES Depression over tank(Y/N) NO High water alarm (Y/N) N/A Date of pumping NEW Pumper - C. ABSORPTION FIELD DATA I*BELOW FINAL GRADE Date installed 8/18/2017 Soil rating p.dor ft2/bdrm) 1.2 System type DEEP TRENCH Length 42 ft. Width 2.5 ft. Gravel below pipe 6 ft. Total depth *9.5-10.3 ft. Eff. absorption area 504 ft2 Monitoring tube YES Depression over field NO Date of adequacy test NEW Results (Pass/Fail) - For 3 bedrooms Fluid depth in absorption field before test - in. Water added - gal. New depth - in. Elapsed Time: - min. Final fluid depth - in. Absorption rate >= - g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N &type) NONE KNOWN If yes, give date - INFORMATION ON 1997 TRENCH IS IN THE MOA RECORDS D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at .. wa er alarm level at in. - -•• Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: SERVED BY PUBLIC WATER Septic . . .. tation on lot On adjacent lots Absorption field on lot On adjacent lo Public sewer main '.e ' sewer manhole/cleanout Sewer/septic service lin- Holding tank .'••: ontainment areas Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5+ Property line 5'+ Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS ..4•%_ OFlookism',1 IA111 G. ENGINEERS CERTIFICATION P.,.•••" z--.-:•1"...... z--.-:•11! 1♦ I certify that I have determined through field inspections and :;:\,19* �� ••* �•review of Municipal records that the above systems are inconformance with MOA COSA guidelines in effect on this ••• ''} - ttix date. • Gney A. Gorness::c�! Engineers Printed Name JEFFREY A. GARNESS • --- :% CE-795 • Date .? '_ 'I -,- 11 PROFESS��P�•� LICENSE 11�11%s"s��� #AECC884 (Rev. 10/12/12) , • 6 A)51);11, . azst, 11/ id ;4/,. 0 1/v. iI 1 ° J) r .. i::: -.St s w � It ' • \\*:11.r.-- •--- IQ/ �� ,IDZai, // fig z . Zr del.. a 61.., • g oh ,‘ ,,,,\ liv 7 �V� 11 \ A" /-g 1/��G�� 29•7;--/L5-47 ASBUILT SEWARD & ASSOCIATES LAND SURVEYING 694-0829 I HEREBY CERTIFY THAT I HAVE SURVEYED THE SCALE=S0��$ a � � FOLLOWING DESCRIBED PROPERTY: J�D � ..5:4,1-;f.,-;.6:,--- t `/�7��,u ��D,/CoT7,BF ".- DATE- ,a�; .. .• S AND THAT NO ENCROACHMENTS EXIST EXCEPT AS ��O a�k . •' .:t. INDICATED. IT IS THE RESPONSIBILITY OF THE �� r . 47" �1 ,'_ *4 OWNER TO DETERMINE THE EXISTENCE OF ANY GRID= '`"" 4 EASEMENTS, COVENANTS., OR RESTRICTIONS '' ..5"Z "#.C €„� ;/ ,' d WHICH DO NOT APPEAR ON THE RECORDED SUBDI- p---- . Duane Mark Seward .-� VISION PLAT. UNDER NO CIRCUMSTANCES SHOULD F&may'�� t ... Ls yS A$ � 4 ANY DATA HEREON BE USED FOR CONSTRUCTION _ r- `4,• ,5 4' OF FENCE LINES, OR FOR ESTABLISHING BOUND- DRAWN: 1.'��r'i-e Skr.;t; . C.�,�' ARY LINES. �,� ra•a.:l• i MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. # ~,~,~,Z-~'~ ¢~'-E~¢~//,¢ ~' HAA # ~.~ 1. GENERAL INFORMATION Complete legal description Location (site address or directions) Property owner Mailing address Lending agency Day phone Mailing address Agent Day phone Address Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: TYPE OF WATER SUPPLY: Individual well Community well Public water NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. TYPE OF WASTEWATER DIBPOSAL: Individual on-site Holding tank Community on-site NOTE: Public sewer If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-4)29 (Rev. 1/91) Front MOA #21 STATEMENT OF INSPECTION BY ENGINEER .. ~. As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm ]~agJe ]~{ver Eng~eez-j_a~' SerMces Phone P.O. Box ~73294, Ea~le l~dver, AK 99577.32o~ Address Engineer's signature Date 11- ~-q-~' DHHS SIGNATURE Approved for Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: Additional Comments The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DH HS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025(Rev. 1/91) Back MOAf¢21 DEC 03 1998 Municipality of Anchorage MUNICIPALITY OF ANCHOP..AGE ~'~. ~ DEPARTMENT OF HEALTH & HUMAN SEL~I~I~NTALSERWCES Environmental Services Division 825 L Street, Room 502 · Anchorage, Alaska 99501 · (907) 343-4744 Health Authority Approval Checklist A. WELL DATA Well type Log present (Y/N) Total depth Sanitary seal (Y/N) ~t./~ If A, B, or C, attach ADEC letter. ADEC water system number Date completed Cased to Cas~ t (h~above ground) Wir~roperly protected (Y/N)  AT INSPECTION FROM WELL LOG Date of test Static water level / Well production ~ ~/~iRmSAM P~'S TI~S: Nitrate D~l~sample: B, SEPTIC/HOLDING TANK DATA g.p,m. Collected by: Date installed ~L--/,~ .-,~ ~ Tank size Foundation cleanout (Y/N) Date of I~"'u~Ping g.p.m. Other bacteria / ¢'¢"~.?~ / Number of Compartments ~ Cleanouts (Y/N) Depression (Y/N) ,"¢/~' High water alarm (Y/N) ~¢/x,,,¢ Y C. ABSORPTION FIELD DATA Dateinstalled ~"--/~"~ _ Soil rating (g.p.d./ft~orft~/bdrm)/,?-- Length '~'~- ~ '~/ Width , Gravel thickness below pipe Effective absorption area ~ ~z' ~- ............. Monitoring Tube present (Y/N) ~ Date of adequacy test /f-/'// Results (pass/Fail). ,/b,",,¢ Fluid depth in absorption field before test (in.); Fluid depth ////"~ (ins) Minutes later: Peroxide treatment (past 12 months) (Y/N) System type ~' / Total depth · Depression over field (Y/N) For ,.'>/,,'¢ 4'~ Immediately after///,(gal, water added (in.): Absorption ram = /~/~ g.p.d. If yes, give date /~/,'~ /4,,/ .bedrooms 72-026 (Rev. 3/96)* D, LIFT STATION Date installed Size in~q~s'''''''~~ Manhole/Access (Y/N) ~~n~ ...... Pump off" level at* High water alarm level at*__ ~ *Datum E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELLON LOT TO: Septic/holding tank on lot Absorption field on lot Public sewer main On adjacent lots ~a~jaconi o s Public sewer manhole/cleanout Lift station SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO: Foundation [ j, i Property line ~-~' Absorption field Water main/service line '~ Surface water/drainage .~D Wells on adjacent lots Property line Surface water Curtain drain SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: J ')-- ~ Building foundation ,4-~- ' Water main/service line Driveway, parking/vehicle storage area Wells on adjacent lots ~/~ ENGINEER'S CERTIFICATION I certify that/have determined thru field inspections and review of Municipal in conformance with MOA H~ guidelines in effect on this date. Engineer's Name Date 11~ HAA Fee $ (,...~,¢L~ , .--- Date of Payment Y~ Recei pt Number ~ ~ ~ S~ ('7~=~) 72-026 (Rev, 3/96)* Waiver Fee $ Date of Payment Receipt Number