Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
STOLLE BLK 3 LT 6
Stolle Block 3 Lot 6 #020-021 - 18 Municipality of Anchorage,,,:• Development Services Department fw: I',!,. U. Building �. ���. Safety Division On -Site Water and Wastewater Program, 4700 S. Bragaw St P.O. Box 196650 Anchorage, AK 995196650 Page' of 3 www.cl.anchorage.sk.us (907) 343.7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: � ogo3gC% O _0D I _ to PID Number: N.m. DO ki Mr) Wastewater System: ❑ New ❑ Upgra e• ABSORPTION D P'• r NwnO« N BMoanF 7 0 DFp Trarwh O SM1Mor Tr«rA O BM Mpny py, LEGAL DESCRIPTION '"° TNat1) le.rll«l nr „d. &ttA lr auebMron' / 3 6 Gpod•P D«aM1N«pa troll «qwr rWa .avM ,eiWM FI To• p R.V. •L/` BMlon' Fl. Fe add6" nal anal radaz Gr +.lL«gln fl Well: ❑New ❑Upgrade ar.W diM1 � w FI. R«ro.rr Dl.l.nc. GINY.uaon (pf ala. A. FTI.1 Tar Dpal C. Iolr ab.. «aa FI. M -1.0q I Ft. Fl Near. •+i.a, blare W.I. l•«N YlraMr', Oal. anlN.d YI«d Ft G FI. L TANK SEPARATION DISTANCES iRSeptic ❑ Holding ❑ S.T.E.P. ❑ Other: Absorption Lilt Field Slalion Hoklmg ubliul"Ovate Tank Srner line,/��orN �� ^ 1M.I«W ^ «WGUn ISepticc LIFT STATION 1 ov1�.ar ' rm.t /y� ' pllnV {44. { {lpdr ENtlrK�l «ap.ctlpn. p«1«mM E,twj Ii •5 16g A4 11 It I A BENCH MARK Lor i,onw De« ps n rile ale AQ nti, it whit\{tamit ! OF S i S tNGINttRINC Inspections performed by: 117034 Eaglet River loop Read, Ne.f2DIQs: 1" "j I..—: Myer, Alaska 99377 M1a »»�,ff�� a ::•• 2 / O �e ROBERT C COWAN,rC j Developme t Services Department Approval ��` CE 88„1 �,,,• +�11rf Reviewed and approved by: Date: �e[rkfle- PERMIT No. SW040399 PACE 2 OF 3 Municipalit of Anchora e DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 •Anchorage, Alaska 99519-6650 • Telephone 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT LEGAL LOT 6, BLOCK 3, STOLLE S/D P.I.D. NO. 020-021-18 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — MT•�EXIgryNG LCAC DBU t DBL2 yygR£q "HC/f(p I Ti ST uv Tut vt fkS I TOECµ 'Y6 4/ 0 C04 N I o pEC a I I I g QI I (INTI f X�Sr�NC G W I R4 V f(. ORiV W f{yAr SCALE: V b0' ,Iop? X ............ \ T •• ROBERT C_ tOWAN % Q 01 ca 01 \ \ 1'1 CSR. M ^,.�•`,n �. PERMIT NO. SW040399 PACE 3 OF 3 DEPARTMENT OF AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 *Anchorage, Alaska 99519-6650 • Telephone: 343-4744 W ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT LECAC, LOT 6, BLOCK 3, STOLLE S/D P.I.D. No. 020-021-18 ST 1 ST2 � 101 .1 FINAL GRADE NEW 96.4'1300 GALLON POLYETHYLENE SEPTIC TANK 2" INSULATION 96.1' N. T. S. A B FCO _1 10.0 11.0' §T 16.5 17.5 ST2 19.5 20.5 TMT 72.5 16.0 DBL1 22.0 23.0 D81-2 23.5 25.0 2" INSULATION 96.1' N. T. S. MUNICIPALI7YOFANCHOR4GE Ip'�L.( MDO Development Services Department 1 On -Site Water 6 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Sep 22, 2004 Expiration Date: Sep 22, 2005 Permit Number: SW040399 Parcel ID: 020-021-18 Legal Description: STOLLE BLK 3 LT 6 " Design Engineer: 0003 S & S Engineering Site Address: Owner Name: DAN TOOMEY Lot Size: 64504 SQ. FT. Owner Address: 16000 HONEY BEAR DRIVE Total Bedrooms: 4 Permit Bedrooms: 4 ANCHORAGE. AK 99511-3103 This permit Is for the construction of: Q✓ Disposal Field E✓ Septic Tank Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be In accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3• The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By. Date: '76- 3 /o Y Issued BDate: ?z . \ Municipality of Anchorage 1 ••a e•, • Development Services Department ; • .r / Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.cf.enchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE F=AMILY DWELLING Parcel I.D. 0 a0 d f ` f 4 Permit Number SW Propertyowner(s) T>ASS TOO MEy Day phone ZZ1I"503 ailing address (1) e , o address (2)I(�a Zip Code lig S 1 \ U Legal description (Lot, Block & Sub'd.) kD . �i S%o�jfi S t' p Legal description (Section, Township & Range) Lot Size 6 A E�4 •-Aeres/Sq.FI. THIS APPLICATION IS FOR: Number of Bedrooms _+ Sewer Only ❑ Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade 1R THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above Information Is correct. 1 further certify that this application is being made for a Single Family Dwelling and is In accordance with applicable Municipal Codes. 7 (Signature of property owner or authorized agent) Permit Fees:• �% G 0 • Waiver Fees: Dale of Payment: q//'7/0 Y Date of Payment: Receipt Number: o S S ; f _ �pM Receipt Number: (Rev. 12100) S & S ENGINEERING Eagh Rh o Alaska 99577 ROBERT C. COWAN, P.E. CML ENGINEERS (907)6942979 FAX(907)694.1211 September 14, 2004 IEALTNARNONTY APPROVALS MUNICIPALITY OF ANCHORAGE Development Services Department SENER&WATER P.O. Box 196650 LVMDOEPSKM Anchorage, AK. 99519 REFERENCE: Lot 6, Block 3, Stolle Subdivision SEWER a WATER WSPECraN It is requested that you issue a permit to upgrade a septic system to serve the existing four bedroom dwelling on the referenced property. ENGMEERW3Sn MS ANOREPORTS The existing septic tank has been compromised & is no longer adequate for use. This septic tank needs to be replaced to allow the existing system to function properly again. WELL WSPECTION A proposed upgrade design is attached & permit is requested to proceed with installation of a FLOW TEST a new septic tank immediately to replace the existing compromised septic tank. This new septic tank will be connected to the existing leachfield. SITE PLANS We do not anticipate any adverse effects on neighboring wells, septic systems, reserve areas or drainage patterns by the installation of the proposed septic system. The construction of this system will not prevent any future development on any of the adjacent PpADDES*, properties. If you require additional information, please contact us. NEST Sincerely,, PERCOLAno, -& 2Z,,— TEST Rdbert C. Cowan, P.E. RCC/jhm aTRucTLaLa Enclosure LIEC'wRrx E45PECTIdb CA SITE WASTEWATER 06POSALSYSTEM DESIGN 17034 NORTH EAGLE RNER LOOP • SUME204 • EAGLE RNER ALASKA 99577 SEPTIC SYSTEM UPGRADE I"= mfg :ED@ V V m Eo I 0 A Nyw 1 I Amo o c ani 2 I o Ns�� O 8q0 ZO n I C~Z 55 N Inn QQ o mwq Z I Y srnava i13m.00I. I V V m o I 0 A Nyw 1 I N m� Z'� ani 2 I fig O 8q0 ZO n I �mz r I rri 1 o srnava i13m.00I. i D X D X 8 n n 1p p O T J r ZI Z v z NZ I Z'� o ml O N y I Z� I A I I I I I I I I I I I I I i D X D X 8 n n 1p p O T J 1ICJ ROBERT C. COWAN, P.E. CML ENGINEERS (907) 694-2979 ON-SITE WASTEWATER DISPOSAL SYSTE1IIiFAAX(907)694-1211 CONSTRUCTION PRACTICES and HEACHA ffHO M MATERIAL SPECIFICATIONS APPROVAL! REFERENCE: Lot 6, Block 3, Stolle Subdivision SEWERSWATER September 14, 2004 ►ori FMEl6gN9 GENERAL: SEWER/WATER 1. The scope of this project includes the upgrade of the existing system, INSPECTION with replacement of the 1250 gallon septic tank to serve the existing four bedroom residence located on the referenced property. EN ?XV W43T"-S 2. Construction shall be in accordance with the approved site plan and ANOREPORTS design drawings, Municipal permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. WELL NSPECRON MCWTEST 3. The contractor shall be responsible for obtaining any necessary underground utility locates. SAMPWB 4. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. RCM DESIGN 5. Contractors installing wastewater disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval from the SOI TEST Municipal Health Department. PERCOLATION TEST SEPTIC TANK INSTALLATION: I. A septic tank is to be constructed by a certified septic tank manufacturer. STRUCTNMII Construction shall include two 4" cleanouts for pumping access. MCHANCAL INSPECTIONS 2. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. ONSITE WASTEWATER OISPOSALSYSTEM DESIGN 17034 NORTH EAGLE RIVER LOOP • SUITE 204 • EAGLE RIVETI, ALASKA 99577 Page 2 Lot 6, Block 3, Stolle SID September 14, 2004 3. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 4. Septic tanks installed with less than 4 fl. of cover shall be insulated. 5. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 fl. from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. 6. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. 11IINIDIUDI MATERIAL SPECIFICATIONS: 1. Any septic tank proposed for installation must be constructed by a Municipal approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Tyne of Pine Perforated Solid Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (11DPE) Yes No ASTM D2662 (ABS) Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. Page 3 Lot 6, Block 3, Stolle SID September 14, 2004 6. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the #200 sieve. 7. When sand is being used as a filter material, its gradation specifications must conform to current M.O.A. or D.E.C. requirements, which ever requirement applies. INSPECTIONS: Typically there will be a minimum of three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: 1. The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. 2. The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement of any other backfill. 3. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required. Especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre -construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractors activities. The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractors activities. Final acceptance of the contractors work rests with the owner and the M.O.A. S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOR/INSTALLER /l-\ MUNICIPALITY OF ANCHORAGE �1 DE ITMENT OF HEALTH AND HUMAN SER% cS Environmental Health Division 825 "L" Street, Anchorage, Alaska 99502, Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NameDISTANCES Br °5W(jkf7�� TO FROM SEPTIC TANK K ABSORPTION FIELD WELL AtltlfeSS 16000 koyle 4ea� Permit Nff No. of Bedrooms IRS-05-08 I 3 WELL /l `,EOPhone(s) LOT LINE LEGAL DESCRIPTION Lot Block � Subdivision S � FOUNDATION Township. Range, Section a? �+/ / �// sJ 6 AS-BUILT DIAGRAM tlrrveway, water bodies, (Show location of well, etc.) septic system, property lines, foundation, TANKS SEPTIC ❑ HOLDING t Pr ap,.PrTy00 7I ManufacturerCapacity in gallons 2 e® Material No. of Compartments TYPE OF SYSTEM (,TRENCH ❑ BED ❑ W. DRAIN ❑ OTHER i - 1$4j. n! Depth to pipe bottom fromTotal original grade q a7 FT depth from original grade /' (� FT —5 76 -r E ff 9 S,e FII added above original grade FT Gravel depth beneath pipe FT Gravel length � FT Gravel width , 3 m FT _ Total absorptmn area 141/9 SQ FTJ Distance between lines FT Number of Imes Soil rating g� SOFT Pipe material 1' PVC Installer �E Dale Installed �v` ha Vei. �` WELLS PRIVATE ❑ OTHER pdentiivl Classification (A,B,C) Total Depth 3 2_ (0FT Cased to / .3Z CO FT Installer �r Alf Date Installed. REMARKS: o2 !412i-cl//,. !La I i/ Wit/ e r ,� l / Seat Inspections re or``med by: ENGINEER'S SEAL ®®®��® OF 44 �� o°e0000 A �y °doe op°¢, Q d7�g roD�O%�M l o ® o °0000000vooS e °moeoo $o°000e e ®Gt oo 3-0mes B. Nowak �Q � o°° ME 5903 Date �j /y �/(i I ` I ly thal is 1 ins Ilion was peliormed according to all u icipal and Slate guidelines in ellecl an Ihis tl te: Health Department Approval: Dat©®FppAp°00°e e: 72-013 (3/85) V — ^ P1 M-11 §�J 1 :1 W--" n- L 1 C] F= AN P4 CC FA C3 FT AN C3 EL_ DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L STREET, ANCHORAGE, AK 99501 264~4720 . PERMIT NO: 850508 DATE ISSUED: 08/15/85 ` � APPLICANT: BILL SHVLER , ADDRESS: 2861-W INTERNATIONAL AIRPORT RD. ANCHORAGE, AK 99501 * ` CONTACT PHONE: 276-6664 LEGAL DESCRIp: SUBDIVISION: STOLLE LOT: 6 BLOCK: 3 � SECTION: 16 TOWNSHIP: 11N RANR& A LOT SIZE: ,5A (GQ.FT" OR ACRES) MAX BEDROOMS: 3 Listed below are the options available to you in designing your septic system. Choose the option that best fits your site! ___._~-__- ___________--. 'T- lit 107 01 C2 1-1 :EF.�t TEP IVJ 11 ID�C-4h I P10 DEPTH TO PIPE BOTTOM (FT.) 3"0 4"0 4"0 GRAVEL DEPTH (FT") ` 3"01 0^5 2"0 TOTAL DEPTH (FT,) 6^0 4"5 6"0 GRAVEL WIDTH (FT.) 2A 19"0 5"0 GRAVEL LENGTH (FT.) 73"0 35"0 62"0, GRAVEL VOLUME (CU. YDS. 23"7 . 24,7 28"8 TANK SIZE (GALS) 1,000"0 ** 1,000^0 ** 1,000"0 ** SOIL RATING (SQ,FT"/BR) 146 146 146 ** DEPTH TO PIPE BOTTOM < 3^5 FT" REQUIRES INSULATION ** DEPTH TO PIPE BOTTOM < 4"0 FT" MAY REQUIRE A LIFT STATION ** TANK MUST HAVE AT LEAST _.~_-______^^~_____~___~-__--_~__.__.-_-__ TWO COMPARTMENTS � ` I certify that: 1" T am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage (MOA) and the State of Alaska" 2. I will install the system in accordahce with all MOA codes and regulations/r and in compliance with the design criteria of this permit. 3. I will adhere to all MOA and State of Alaska requirements for the set back dAstances from any existing well, wastewater disposal system or public sewerage system on this or any adjacent or nearby lot. 4. I understand that this permit is valid for a maximum of 3 bedrooms and any enlargement will require an additional permit" ^ ' IF A LIFT STATION IS INSTALLED IN AN AREA COVERED BY MOA BUILDING CODES� THEN (1) AN ELECTRICAL*PERMIT AND INSPECTION MUST BE OBTAINED; (2) AR-BUILTS WILL NOT BE APPROVED WITHOUT AN ELECTRICAL INSPECTION REPORT; AND (3) THE ELECTRICAL WORK MUST BE DONE BY A LICENSED ELECTRICIAN" SIGNED DATE: APPLICANT ER ISED BY DATE: ---~--- ----- yn------~~ 0 November 4, 1983 Mr, Bill Shuler c/o Coffman Engineers, Inc. 550 West Seventh Avenue, Suite 700 Anchorage, Alaska 99501 SUBJECT: ON-SITE WASTEWATER DISPOSAL SYSTEM FOR LOT 6, BLK 3, STOLLE SUBDIVISION LOCATED WITHIN NE 1/4, SECTION 6, TOViNSHIP 11 N, RANGE 2 W, SEWARD MERIDIAN Gentlemen: This report presents the results of the subsurface soils investigation of the above - referenced lot in Stolle Subdivision. The testing was accomplished on October 20th, and 21st, 1983. The purpose of this investigation was to assess the soil for suitability of on-site wastewater disposal systems. Included in this transmittal are: 1. Test Hole Location Sketch. 2. Test Hole Log. The subsurface investigation was conducted using a minuteman drill fitted with a continuous flite solid stem auger. The drill is owned by Bomhoff and Associates, Inc. Drilling was supervised, the test hole logged, and the percolation test performed by Rick R. Koch, Civil Engineer with Coffman Engineers, Inc. After drilling was completed the test hole was backfilled to the bottom of the strata to be tested and was filled with water and continously refilled for a period of two hours before testing. Prior to the test, the water level was lowered to the top of the strata to be tested, and the drop in water level was carefully monitored over the next 60 minutes, Using the above test, the observed minimum percolation rate was 6.7 minutes per inch. We recommend that the seepage trenches be inspected prior to installing the system as the above percolation rates are based on the result of a three and one-half inch test Mr. Bill Shuler November 4, 1983 Page 2 hole. The seepage trench will provide a much clearer picture of the subsurface conditions than the test holes. If conditions are different from those encountered in the test hole, it may be necessary to lengthen or enlarge the trenches. I hope this report meets your present needs. If I can be of further assistance to you, please feel free to contact me. Sincerely, Jan M. Nick, P.E. Civil Engineer hlkw OF A<Ar a, -i*'49T .i ..:ee...r:�...1�•....... . 9 • •: C • : y � ® C .• Jon M. Wick. f, J'l. '•� CE -5838 Vim/ ' ,ST NC LE tory el', /3 /cc k 3, 5'�c//r OD VIII 61-"c3rvw., crJc'^t,c Salt 4�( ,, S; P0 Sc„tri �rc�c1. rL 0. . G E�� r It, bui r oc_k 15 AAA• p�Optl // ` IOCdIiOn ®wem Coffman Engineers, Inc. �3oi�ar, 0 1301-( 'j I� • c SftBel M DD n0 cM1ecked dote ry ff -. st ax w� P.rY.- AS!'/'RDI u u 15 P r f• •f /flC TCST r•�ol-C- Ir M /Arfp J N G'S`'It'C 1//!'Sit \2• I d � tr ,5 •� (14 Ar 1G� Sfl'1• " a � !L Ac lG Zai A 77 Ac F.r }A let cT 1 Lrc tmf l.a v..rw.<c�� M'r's "\ !!7AC l i / 6 i .• I �'r!5\�, '�.�� J- K� �� a v t \\ � 'I fr S \ `•'D •� i 7f C � N f• �. ,TN' ire r trr.' Easel C� ` \ S �. Fr.'4t17 Av 0 • 1 / t t Ac �. Irl '1 AA /7/. 01 S^ t�,,r Npn►C� ¢ 4�y /16 �s � ♦zc� s 4J✓tu< !' � '� � tt F Lar/ -T i �r&t/ 4/� �' S � � yt.r/ / y�t3r rY • y efst or/sf.�7DJ 3 /0, Wf s - BLJC ® � � ILA& a PROJ ECT:.SfkiLE-11 WAN%IL lvju, - DATE: Coffman Engineers, Inc. JOB NO.: MEMO { ...ire. NOT purpose: 7S Ti 0 R®x 13695, STAYS lRouwR A ANciaouAcmv ALASKA 99502 844-7714 SIX INCH WATER WELL DRILLED AND CASED OUT TO THE DEPTH OF 337 Feet. DRILLED AT THE RATE OF 23.00 PER FOOT. Cha&e Pt 32-J A ofL%. PROPERTY OWNER ft. &illy• BtU. & Thaac l4 SCkULCR 248-22.32 276-6664 LOCATION OF WELL SITE a. Bdk. Sub. g&andvtw- DRILLER BeJvu.e Ctau4 a� Rampant !fttitt ¢ bJo&k4. WELL LOG: 0----16' S.i,4 4an.dy. fAne ghavet. 40% cLaty bin.deA. 16---24' Coa 4e dW 9,,muet. 24--337' Bed&ock. A 4edt-aaan tph.ic. tock. UnU4414V4 hand. Ra watelt p2oductioa 4h04 ng Wl tU 255 to 258 �,t. A_ �urur {arc maty i a G �i e Cd+n& about 1 1 /2 9—& 291 to 294 A a 4O 4how4 about 1 1/2 V& IRa2e azeao ./ham 315 to 321 4 41au' at One H044e SubmeU4,&te 4hould be ttwtal teal 20 .fit o" bottom. OMAN Co,jt o.- aVAUn.g: $23.00 Aet .fit x 325 4: $7475.00 SM 8 T d33 ILO 02 4et. up. coot. N0110310dd 1b1N3WN0dIAN3 9 H1lV3H do ud3Q ........ ------�s- SovdOHJNV 40 d11lVdI01NnW 1112.�.1.p,AUt,{�.�I1L,w'�it'u ?— . & lIULJ. B.11l. 6nda j th,i 23-%d, 198�r . COST INCLUDES ALL LABOR AND MATERIAL FOR COMPLETION OF SAID. LLING@ Pard to TwU .. s WRITE CHECK PAYABLE TO RAMPART DRILLING WORKS FOR THE SUM OF ---------------- THANK YOU VERY MUCH. BERNIE CLAUS OF RAMPART DRILLING WORKS DATE;"g 27th., 1984 7w-> a SERVICE CHARGE OF IV,% PER MONTH WILL BE ASSESSED ON PASTD ACCOUNTS. Parcell.D, 020-021-18 e� Municipality of Anchorage On -Site Water and Wastewater Program (907) 343-7904 Certificate of On -Site Systems Approval 1. GENERAL INFORMATION Complete legal description STOLLE BLOCK 3 LOT 6 LJExpiration Date: / /, JL Location (site address) 16000 HONEY BEAR CIR., ANCHORAGE, AK 99516 Current Property owner(s) DAN TOOMNEY Mailing address Real Estate Agent Day phone 229-5031 Day phone 2. TYPE OF DWELLING: -T x❑ Single Family (w/wo ADU)4 ❑ Duplex F-1 Multiple Dwellings(Single Family and/or Duplex) JUN 18 2014 L 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual 0 Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public (Nater System ❑ Pi,hlic $awar F-1 WaiverNariance request for: NONE Distance: ___ Received by _ 'ZL -� Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 52-(*— Waiver Fee $ Date of Payment (c I I �I (H l.V`a, Date of Payment Receipt Number oi%-1 � Receipt Number COSA# oe,,CtLi��A Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm SPURKLAND ENGINEERING Address 203 W. 15TH AVE.,STE.202A, ANCHORAGE, AK 99501 Engineer's Printed Name LARS SPURKLAND �IWPI:I-*1 1elLlGYlq:4 Phone 279-3916 Date 6/17/2014 -<i .OF ....A... It r a H 9� �......... .. ...1..., f f System #1 Approved for bedrooms �, LAR �nSPURLAND.-'&-7 ".K ; System #2 Approved for bedrooms15 0 rr Disapproved�$,P Conditional approval for bedrooms, with the following stipul��#brts���'` By: Original Certificate Date: i' The uni6 alit f Ancf). a Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the repreantationt ggiven in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSAblueshaetr .- .. If more than 1 septic system is on the lot: COSA Checklist # 1 of 1 Structure served by this system 1 Certificate of On -Site Systems Approval Checklist Legal Description: STOLLE BLOCK 3 LOT 6 A. WELL DATA Well type PRIVATE If A, B, or C provide PWSID # - Date completed 9/18/85 Sanitary seal (Y/N) Y Total depth 337 ft. Cased to >40 ft. FROM WELL LOG Date of test 9/18/85 Static water level 75 Well production 5.5 WATER SAMPLE RESULTS: ft. Coliform NEG colonies/100 mL Nitrate 0.148 mg/L Arsenic ND ug/L Date of sample: 5127/14 B. SEPTICIHOLDING TANK DATA Parcel ID: 020-021-18 Well Log (Y/N) Y Wires properly protected (Y/N) Y Casing height (above ground) 12+ in. AT INSPECTION 5/27114 192 1.2 Fill g. p. m. Collected by: ANSON MOXNESS Tank Type/Material SEPTIC/SHDPE Date installed 10/14/04 Tank size 1300 gal. Number of Compartments Cleanouts (Y/N) Y Foundation cleanout (YIN) Y Depression over tank (Y/N) N High water alarm (Y/N) N Date of pumping 6/2014 Pumper A+ HOME SERVICES C. ABSORPTION FIELD DATA Date installed 9123/85 Soil rating (g.p.d./ft2 or ftz/bdrm) 146 System type TRENCH Length 75 ft. Width 3'5 ft. Gravel below pipe 3 ft. Total depth 6'5 ft. Eff. absorption area 600 f 2 Monitoring tube Y Depression over field N Date of adequacy test 5/27114 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 15 in. Water added 530* gal. New depth 31 n. Elapsed Time: 180 min. Final fluid depth 16 in. Absorption rate >= 600 g p d Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date D. LIFT STATION Date installed Size in gallons_ Manhole/Access (Y/N) - "Pump on" level at W in. "Pump off" level at — in. High water alarm level at Datum E. SEPARATION DISTANCES WELL ON LOT TO: Cycles tested Septic tank/lift station on lot100+ Absorption field on lot 100'+ Public sewer main NA Sewer /septic service line 25'+ Animal containment areas 50+ Meets alarm & circuit requirements? _ On adjacent lots 1001+ On adjacent lots 100'+ Public sewer manhole/cleanout NA Holding tank NA Manure/animal excrete storage areas 100'+ SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5+ Property line 51+ Water main NA Water service line 10'+ Wells on adjacent lots 100'+ ABSORPTION FIELD ON LOT TO: Property line 10+ Building foundation 10+ Water Service line 10'+ Surface water 100'+(N.O.) Curtain drain 50'+ (N.O.) Wells on adjacent lots700+ F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name LARS SPURKLAND Date 6/17/14 COSA brown sheet_10.10.12.doc Absorption field 51+ Surface water 100+ Water main NA Driveway, parking/vehicle storage10 in. Spurkland Engineering Environmental Consulting and Design SEPTIC SYSTEM DESIGN STOLLE BLOCK 3 LOT 6 Municipality of Anchorage Development Services Department On Site Water and Wastewater Program 4700 Elmore Road Anchorage, Alaska 99519 Subject: Ladies and Gentlemen: COSA Application June 25, 2014 The septic system adequacy test was at the above referenced property was conducted on May 28th, 2014. Over a 6 hour period, 530 gallons of clean water was added to the drain field. This caused a rise from an initial water level of 15 inches to 31 inches. Over a 3 hour period the water level dropped 15 inches. During this 3 hour period the drain field disposed of approximately 290 gallons, by extrapolation, over the next 21 hours the drain field could dispose an additional 6090 gallons. If you have any questions or concerns, please contact me at 279-3916. Sincerely, i Lars Sptland, P.E. Civil Engineer 203 West 15t" Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland@gci.net t ' ug Address `} Unless otherwise requested, HAA will be heI 2 .NUMBER OF BEDROOMS: �jq q Day phone a 76 x767 individual on-site At. n, Holding tank Juu attesting to the Is a 5. STATEMENT OF INSPECTION BY'ENGINEER As certified bymy seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply q and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my invest�qation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this 'nspection. Name of Firm' ', A LA3V_a 'WA-,�JZ �j LUU44S u/ Phone . 3? 7—b %7q Address 0411 Q �- 4.. c4 - Date'. .. /I Z 4' Engineer's signature " + , OfMA if 3 , t kPROFESS\ O• .6. DHHS-SIGNATURE .. , Approved for ° `•bedrooms if � il.f ` t +... I i P,� 4 � Disapproved Conditional approval for bedrooms, with the following stipulations The Municipality ofAnchorage,Department of Health and Human Services (DHHS) issues1 1, Heaith'Authority .a Approval Certificates based only upon the representations given in, paragraph 5,Pby an independent professional engineer registered in the State of Alaska. The DHHS does th is as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct Inspections orYanalyze data before a certificate is issued The Municipality of Anchorage is not responsible forerrors orr omissions int herofessional engineers work.',,, p 9 0, 6401 1N T2-025 (Ra 1le1) B•ck MOA Nit � - i, r , Municipality of Anchorage Department of Health and Human Services HEALTH AUTHORITY APPROVAL CHECKLIST Lo -r6) BK 3 Legal Description: 51r0 t LF-- 511> Parcel I.D. A. Well Data 6 i 2 Feu m � M C � M t� 4O N a Well type 121 �� +'�F- If A, B, or C, attach ADEC letter. ADEC water system number � Log present (Y/N) Nkr= S Date completed 2 6 Driller {ZPMP Z rr c Z 0 Q z z 0 c Total depth 3 37 Cased to 337 Casing height 12 f Sanitary seal (Y/N) VAS Wires properly protected (Y/N) FROM WELLL G AT INSPECTION Date of test %Z /3 + 1013C)A+ Static water level 75 1 S(S�F covUL Well flow 4 . 5— 5. 57 g,p,rn. I g.p.m. Pump levels 20 Fr. cF=F BQrm-Pi UNK+uawtJ SEPARATION DISTANCES FROM WELL TO: Septic/holding tank on lot Absorption field on lot l 90�+ ; On adjacent lots Dy / Public sewer main A Public sewer manhole/cleanout N 44 r Sewer service line t o0 Petroleum tank NIA -I- On adjacent lots >> (00 WATER SAMPLE RESULTS: Coliform d Nitrate (o mG h Other bacteria Date of sample: loboo&E Collected by: S -V B. SEPTIC/HOLDING TANK DATA Date installed 7,SS Tank size 12 50 Compartments 2 Cleanouts (Y/N) Foundation cleanout (Y/N) Depression (Y/N) High water alarm (Y/N) t4 G Alarm tested (Y/N) W( - Date of pumping ISS/ -GS 10/z�t�Pumper �SSFI GS SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: Well(s) on lot I I a 1+ On adjacent lots > > 00 Foundation 6 To property line 35r ` Absorption field �r Water main/service line >I�r oPPoSr 5,06S of /-loaS£ Surface water/drainage Nom 06SEP_Vf_.O 72-026 (3/93)` Front CONTINUED ON BACK PAGE C. LIF STATION Date installe _ Size in gallons_ Vent(Y/N) "Pump Manufacturer Manhole/Access "Pump off" Level at W High water alarm level C cles tested AA Meets MOA electrical codes (Y/N) 3 SEPARATION DISTA�FROM LIFT STATION TO: z Well On adjacent lots Surface water D. ABSORPTION FIELD DATA "PFS ,d4g4 � Date installed %,S-7 Soil ratin (GPD/Ftz) / (4(o 66prtco/f Systetype Length i5 Width3 , a� Gravel thickness 4 `J Total dept G l� C 2 2' 'Ft Cleanout present (Y/N) Total absorption area ��� SuMP Depression over field (Y/N) N � / Date of adequacy test i0/ 3(0/q4 -Results (pass/fail) for Bedrooms �j Water level in absorption field before test SUMP wAS DRy After test —f Peroxide treatment 12 f`I If date (past months) (Y/N) 118 yes, give SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Well on lot � 30 / * On adjacent lots N 14 / 100 Property line I To building foundation 2 8 On adjacent lots » rroNE o$SE¢vE� Surface water Curtain drain _ _ N E. ENGINEER'S CERTIFICATION 1 certify that 1 have checked, verified, Signature Engineer's N ✓ Date / To existing or abandoned system on lot a� E of Qo�o 101 ofpoS� Srots Cutbank kU (? K Water main/service line W= L SE / Driveway. parking/vehicle storage area 3C± Pte' 1913.9 444 PA062W012-4 z, pe /2- 19Ss AS -Burr -7 to all MOA and HAA guidelines 642 ®®A or t�eE55t��� ti :` HAA Fee $ JOb Waiver Fee $ Date of Payment///Date of Payment Receipt Number T �J �% J J7�� Receipt Number. 72-026 (3/93)' Back Alaska Water & Wastewater Services "Preserving The Last Frontier" November 7, 1994 Municipality of Anchorage Department of Health and human Services Division of Environmental Services on -Site Services Section P.U. Box 196650 Anchorage, Alaska 99519-6650 Ref: Well and septic system adequacy test at Lot 6, Block 3, Stolle S/D. To whom it may concern: The subject test/inspections were performed an 10/30/94. The results are summarized as follows: WELL ADEQUACY TEST: The static water level in the well. was 175 fleet below the top of the casing. The test was performed by pumping water at an average rate of 2.34 gpm over a period of 192 minutes (450 gallons). The actual pumping rate varied between 2.36 gpm and 5.18 gpm, but was intermittently stopped to allow the well to recovery_ the pumping is summarized as follows: Time mint!tes O 17 43 56 70 93 Flom Lallons 0 88 216 272 311 351 Water Level 175 217 269 290 300.5 303 Erratic Stopped flow for 12 minutes to allow well to recover 105 351 299 (also filled pressure tank) 122 391 303 Erratic 135 409 303 Erratic Stopped flow for 45 minutes to allow well to recover 180 409 not read 1.92 450 300 approx. The recovery of the wall was then monitored over the next 60 minutes. The results are summarized as follows: Telephone: (907) 337-6179 . Fax: (907) 338-3246 . 8471 Brookridge Drive . Anchorage, Alaska 99504 Time minutes) Water t_evel Meet Vol. in casing (gal.) 0 300 approx. 0 6 296 5.88 1s 289 16.2 20 285 22.1 30 277 33.8 40 270 44.1 s0 263 54.4 60 256 64.7 The volume recovered in the well casing during one hour was 64.7 gallons. This corresponds to recovery rate of 1.08 gpm, when the well is near maximum drawdown. The ability of the well to sustain this recovery rate over an extended period of time is uncertain; however, based upon this data, it appears that the well is adequate for a 3 bedroom house (.313 gpm) at this time. NOTE: The results of the test are only valid for this given day, as the adequacy may fluctuate due to seasonal conditions, seismic activity, annual precipitation, ect. SEPTIC SYSTEM EVALUATION= According to the as -built records the existing trench has 48 inches of drainrock below the sewer pipe_ Prior.to beginning the test it was noted that the sump at the end of the trench was completely dry.. Water was introduced into the trench at the same pumping rate/cycle for the well. test. During the entire test, the liquid level in the sump did not rise, indicating that the water was being absorbed as fast as it was being introduced. TRENCH LOCATED NEXT TO CUTSANK: The existing trench is located at the edge of a 40% cutbank. On the day of my site visit there was snow on the ground; consequently, I was not able to visually see if "daylighting" was occurring. According to the property owner there have not been any operational problems with the septic system. If you have any questions, please contact me at 337-6179 Sincerely, Own, n�ultant s, P E,, M.S. iMurphy2.wps Commercial Testing & Engineering Co. Environmental Laboratory Services�v®�oo�o�®®��o��oo�oma��000©�voo®0000 90B LABORATORY ANALYSIS REPORT CT&E Ref.# 94.5566-1 Client Sample ID 16000 HONEY BEAR CIRCLE Matrix WATER Client Name AK WATER & WASTEWATER SERVICES Ordered By JEFF GARNESS Project Name Project# PWSID UA Sample Remarks: ROUTINE SAMPLE COLLECTED BY: GARNESS. WORK Order 10496 Printed Date 11/02/94 @ 17:04 hrs. Collected Date 10/30/94 @ 13:00 hrs. Received Date 10/31/94 @ 10:55 hrs. Technical Director STEPHEN C. EDE Released Byyv..„ 'W ----------------------------------- ------- -------------- ==== --------------------------------'_________------___'___---_________- * See Special Instructions Above UA Unavailable ** See Sample Remarks Above NA = Not Analyzed ,,U = Undetected, Reported value is the practical quantification limit. LT = Less Than QD Secondary dilution. GT = Greater Than cv IL 5633 B Street, Anchorage, AK 99518-1600 —Tel: (907) 562-2343 Fax: (907) 561-5301 ENVIRONMENTAL FACILITIES IN ALASKA, COLORADO, FLORIDA, ILLINOIS, MARYLAND, NEW JERSEY, OHIO, UTAH, WEST VIRGINIA QC Allowable Ext. Anal Parameter Results Qual Units Method Limits Date Date Init ____________________________________________________________________________________________________________________ Nitrate -N 0.60 mg/L EPA 353.2/300.0 10 10/31/94 MCE ----------------------------------- ------- -------------- ==== --------------------------------'_________------___'___---_________- * See Special Instructions Above UA Unavailable ** See Sample Remarks Above NA = Not Analyzed ,,U = Undetected, Reported value is the practical quantification limit. LT = Less Than QD Secondary dilution. GT = Greater Than cv IL 5633 B Street, Anchorage, AK 99518-1600 —Tel: (907) 562-2343 Fax: (907) 561-5301 ENVIRONMENTAL FACILITIES IN ALASKA, COLORADO, FLORIDA, ILLINOIS, MARYLAND, NEW JERSEY, OHIO, UTAH, WEST VIRGINIA ..... .......... ........ _OCT 25 '94 11:31 REMRX PROPERTIES RFX60 i �0T /2 v �09# . zoo 91 /\/ 69" Lot 6 , Block J/O//e JUZ)c1iv%siar? Anchorage Retarding Precinct, Alaska TIFICATIO I heroaY cerijfy that 1 have aarveyed tt p!aperlY &wwn 04 "1Erf hneon�ard thdl the Wnprovemern sitUdled thareao ate within the pr ptY lima and donor Overlap a encrdadh an adladent pr*Wy and t irwo"Mem de adlocmv propetiy overidp dr enuoaep do the prenM m queatlan and titer theta are np roadwdy6� viitily liriee d dher vN�i01! adxnferd* on 50id 0!aWI Oxaept as indicatad rrorean. scale Date 1 0:5 —.50 Ref. Fa Io. 3S J" 0_ O T a = • r C4^V&'L F�c/ST/Nt IN aa' -® wecc S CA Q p i � Cl� f� Prepared by: R. t.. ourrON Rwa/s*w Gard Swmw - + /9071279-8200 1/9 W, £!g'hM Aw. Anc'h rVe, Akskc -9---If a MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION is DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4720 Application Date^ I 118S range) Location (address or directions) (b) Applicant Namur I r � Sr-%uL�—Telephone: Home VIE -060 � Business�7 Applicant Address 16---20 f (c) Applicant is (check one): Lending Institution ❑ ; Owner/builder Ok; Buyer ❑ ; Other ❑ (explain); (d) Len ding Institution Oifeer;(C Telephone ,. Address (e) 'Real Estate Company and Agent Address Telephone (f) Mail the HAA to the following address: zm_� 1 Co r—�PtA-) aj,51-.v .5 s -5o 4)4-sT 7-n4 Su rzG 70-z l j 2. TYPE OF RESIDENCE i Single -Family X Multi -Family ❑ Other Number of Bedrooms 3. WATER SUPPLY Individual Well o Community ❑ Public ❑ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 4. SEWAGE DISPOSAL Onsite Public ❑ Community ❑ Holding Tank ❑ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Page 1 of 2 72-025 (11184( 5. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. �J Nnmp of Firm f.G-��t.e� "� CiriP ,c... o_P %' Telephone Engineer's Seal 6. , DHEP APPROV i Approved for i bedrooms by { Approved Disapproved Terms of Conditional Approval Conditional CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & ` n J ENVIRONMENTAL PROTECTION MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 264.4720 R;CLJ Y Legal Description: DoT 6 fi3OclC J 1 dLLLL v A. WELL DATA Well Classification 4?eIf A, B, C, D.E.C. Approved (Y/N) 41 Well Log Present (Y/N) ._ ___ Date Completed - f em Yield 57a Total Depth Cased to� Z G Depth of Grouting Static Water Level %S� Pump Set At 'lOit Casing Height Above Ground Sanitary Seal on Casing (Y/N) Electrical Wiring in Conduit (Y/N) Depression Around Wellhead (Y/N) Separation Distances from Well: To Septic/Holding Tank on Lot On Adjoining Lots /�0✓� To Nearest Edge of Absorption Field on Lot j 3I On Adjoining Lots To Nearest Public Sewer Line � ✓LP To Nearest Public Sewer Cleanout/Manhole wol To Nearest Sewer Service Line on Lot Water Sample Collected by ��/,t" Date ` Water Sample Test R sults �, Comments GT 5'ce, IW B. SEPTIC/HOLDING TANK DATA 12i„O Date Installed Bb Size —�— No. of Compartments Ze Standpipes () N) Air -tight Caps (Y/N) ? Foundation Cleanout (Y/N)— Depression over Tank (Y/N) N Date Last Pumped Pumping/Maintenance Contract on File (Y/N) k ; for Holding Tank High -Water Alarm (Y/N) u Temporary Holding Tank Permit (Y/N) Separation Distances from Septic/Holding Tank: m/ To Water -Supply Well ul% To Building Foundation p To Property Line S'D r To Disposal Field %q To Water Main/Service Line A9/a/+4�O' To Stream, Pond, Lake, or Major Drainage Course Comments Page 1 of 2 72-026(11/84) C. ABSORPTION FIELD DATA Soils Rating in Absorption Straaattaa/ �6 Type of System Design rl?,FA/GL % Date Installed a L Length of Field zs"'� Width of Field 3 ��, TT Depth of Field Gravel Bed Thickness # r Square Feet of Absorption Area Fr�aO / Standpipes Present (Y/N) I Depression over Field (Y/N) Results of Last Adequacy Test Date of Last Adequacy Separation Distance from Absorption Field: r To Water -Supply Well /20 To Property Line / To Building Foundation L 76 f–/ To Existing or Abandoned System on Lot evii. e ; On Adjoining Lots Ae&1.26 @ To Water Main/Service Line 1"4 LQ To Cutbank (if present) oV0,01, e To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area Comments — D. LIFT STATION Date Installed . Size in Gallons ^9 4e "Pump On" Level at High Water Alarm Level at Tested for Electrical Codes (Y/N) Comments. Dimensions Manhole/Access (Y/N) "Pump Off" Level at ** Check Permitted Bedroom Rating Against HAA Request ** Vent (Y/N) Pumping Cycles during Adequacy Test. Meets MOA I certify that I have checked, ve j i , or co formed to all MOA and HAA (guidelines in effect on the date of this inspection. Signed / Date Comp ny r MOA No. S T 8y 2 96 Receipt No. J •3� �� Date of Payment�'c�� Amount: $%' Page 2 of 2 72-026 (11/84) James B. Navrak ME 5903 August 9, 1985 n, DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTIO!! James B. Nowak Genesis Engineers Inc. 1801 E. Dowling Road Anchorage, Alaska 99507 Subject: Lot 6 Block 3 Stolle Subdivision After review of the as-builts submitted for the above referenced property, there are some descrepancies that need to be corrected ?r=or to appoval of this installation. (1) All permits expire at the end of the calendar year if not installed during the year of issuance. This permit expired December 31, 198, and the property owner has not obtained a 1985 permit to install En on-site sewer system. The owner or his representative must come _n this office and obtain a 1985 On-site Sewer Permit. The per --;t fee V� is $20.00. l�(2) There is bedrock at a depth of twelve(12) feet; the bottom of any i system must be six(6) feet above bedrock. Therefore, the total dept= i should not be greater than six(6) feet; the as -built shows 71-2- feet CfE vJ total depth. e p� (3) The as -built says trench design, however, the total absorption coe_ not compute for a trench; the desigh for a three(3) bedroom system 2(sidewalls) x 4.5(gravel depth) = 9 x 75(total lenght) = 675 total square foot absorption area. The total amount on the as -built is 1,680 square feet. 4) The owner needs to submit a well log for his well to this office D'- for record. Before this Department can give approval, the above items must be corrected. If there are any further questions, please call this office at 264-4720. Sincerely, Laura J. Ward Acting Engineer Tech II cc: Bill Shuler 16000 Honeybear Circle Anchorage, Alaska 99515 PG; r1{ F--:`- :4M—M Ar: C rI Q: i DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTIO!! James B. Nowak Genesis Engineers Inc. 1801 E. Dowling Road Anchorage, Alaska 99507 Subject: Lot 6 Block 3 Stolle Subdivision After review of the as-builts submitted for the above referenced property, there are some descrepancies that need to be corrected ?r=or to appoval of this installation. (1) All permits expire at the end of the calendar year if not installed during the year of issuance. This permit expired December 31, 198, and the property owner has not obtained a 1985 permit to install En on-site sewer system. The owner or his representative must come _n this office and obtain a 1985 On-site Sewer Permit. The per --;t fee V� is $20.00. l�(2) There is bedrock at a depth of twelve(12) feet; the bottom of any i system must be six(6) feet above bedrock. Therefore, the total dept= i should not be greater than six(6) feet; the as -built shows 71-2- feet CfE vJ total depth. e p� (3) The as -built says trench design, however, the total absorption coe_ not compute for a trench; the desigh for a three(3) bedroom system 2(sidewalls) x 4.5(gravel depth) = 9 x 75(total lenght) = 675 total square foot absorption area. The total amount on the as -built is 1,680 square feet. 4) The owner needs to submit a well log for his well to this office D'- for record. Before this Department can give approval, the above items must be corrected. If there are any further questions, please call this office at 264-4720. Sincerely, Laura J. Ward Acting Engineer Tech II cc: Bill Shuler 16000 Honeybear Circle Anchorage, Alaska 99515