Loading...
HomeMy WebLinkAboutLot 03 MUNICIPALITY OF ANCHORAGE l DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAl_ SYSTEM AND/OR WELL INSPECTION REPORT T4AME PHONE I ~NEW VAILING ADDRESS LOCATION NO, OF BEDROOMS DISTANCE TO: Manufacturer ~_~__~ Width IF HOMEMADE: Well ~_ Dwelling Manufacturer Material No. of co~l~a~rtments Insidelength Liquid depth PERMIT NO. /-'4 ~ Liquid capacity in gallons Well li~ DISTANCE TO: ~ ~,.~.~"~ / Length Trcnch wid,~ h ~ Top of tile to finish~.~ Material b~Ln'e~[~.z ~ ~V'~', t'~ inches Total effective absor Length ~ Width Depth ~ PERMIT NO. · Type of crib Crib diameter Crib depth Torsi effective absorption area Well Building foundation Nearest lot line DISTANCE TO: ~ -- -- Distance to lot Jlne PERMIT NO. DISTANCE TO: Building -- Sewer line~ Septic tan~_ Abso~rption area(s) OTHER PIPE MATERIALS REMARKS APPROVED DATE LEGAL 72-013 {Rev. 3/78) DEPARTMENT OF' HERLTH AND ENV~ONh'IENTAL PROTECTION 825 L STREET, RNCHORRGE, AK 9950± 264-4720 F'ERMIT [:,ETE ISSUE[:,: :4E0]'2 ENGINEEF:E[:, [ E_.,~ alq .:l_...,.. El._,, : 4 FIF'PLICFINT: DFI'¢ID RN[.', [:,ONNFI MCCFIRRE*/ FIDDRESS: 12.740 F:I TFINFI[:,FI LEiOP RNCHORREiE, RK 995±5 CONTRCT F'HONI,E: ]:45-5807 · i...EGFIL DESCRIP: SUDDIVI_c;ION: STEVRHN 'SECTION: 25 TOHNSHIP: LOT SIZE: :].5600 (SQ. FT. OF;'. RCRES) LOT: RRNGE: E:LOCK ~~¢///4 CERTIFY THRT: :t.. I FIM FRMI!_IRR Hi-f'H THE F:EQUIREfqENT5]. FOR ON-SITE SEI,IERS RND HELLS RS SET FORTH B'T' TFIE PilJNICiPFILIT'¥' OF FINCHORFIGE (i'tOFI) FIND THE S'I'RTE OF RLRSKR. 2. t .[,.iIL. I... tNSTRLL THE SYD;TEPI IN FIC:C:ORDRNCE HITH FILl.. I'"IOR CODES RN[:' REGULRTIONS, RND IN CC$]F'I_IRNCE HI'TI'"I ]"FIE DESIGN CRITERIFI OF THIS PE~;E'IIT. _'3.._i HILL R[:,HEF..'E TO RLL. MOR RND STRTE OF' FILRSKR REQUZR'EMENTS FOR T'HE SET BRCK [:,I';E;TRi'ICES FROM FIN"r' E;:':',tSTING HELL, PJRSTEHRTER DTSPOSRL S?S]'EH OR PUBLIC L'-:qEI.qEF.'FIGE SYSTEM ON THIS OF..' RN'¢ RD..TRCENT OF'. NERF..'B'¢ LOT. IF Fi LIFT STFITiOi'",i iS INSTRLLED IN FiN FtREF! COVERED 8"r' MOR DUILDING CODES., THEN (:L) FiN ELECTRICFIL. PERMIT RND INSPECTION MUST BE O8]"FIINE[:'.~ (2) FIS-BUILTS HILL. NOT BE RF'PRO"/ED HITHOUT RN EL. ECTRICRL INSPECTION REPORT.~ FIND (33' THE EL. EC:TRIC:FIL I.'.IORK MUST DE DONE B'T' FI LICENSED EL. ECTRICIFtN .:, I bi ~[.'.[ DRTE: FIF'F'L. I ClZli",IT: [)i.:1',,,' I [:' F~i'-,l[::, [:~Oi"JNI::I ISSUED D"/. DRTE: MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L, Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST SOILS LOG PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: SLOPE DATE PERFORMED: SITE PLAN 10 11 12 13 14 15 16- 17 18 19- 20- COMMENTS PERFORMED 72-008 (6/79) WAS GROUND WATER S ENCOUNTERED? ~//~ .~ L Gross Net Depth to Net Reading Date Time Time Water Drop ¢',¢~ ~/~/ /~ .'o¢ /,~,/ ~ /~: /~ i~ ~ /~',~o lO /,~7 .D~ PERCOLATION RATE ~ ~/__"OO i/inch) ' TEST RUN BETWEEN CERTIFIED BY: ALASKA eI UIROIlmeI1TAL COI1TROL $eRuI'Ce$, ~n§inecrin9 6 ~nuironmcnl~l Sludies InC. SPECIFICATIONS FOR ELEVATED BED ALTERNATIVE WASTEWATER TREATMENT SYSTEM- LOT 3, STEVAHN SUBDIVISION 1.0 GENERAL 1.1 THE DRAWINGS, SHEETS 1 THRU 3, SHALL BE A PART OF THIS SPECIFICATION. 1.2 ALL MATERIALS AND WORKMANSHIP SHALL MEET THE REQUIREMENTS OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION PERMIT. 1.3 IT IS THE RESPONSIBILITY OF THE OWNER TO OBTAIN ALL NECESSARY PERMITS OR EASEMENTS. 2.0 THE LIFT STATION 2.1 THE STOCK MATERIAL FOR THE LIFT STATION SHALL BE EITHER GALVANIZED STEEL (ASTM A-4444-76), OR ALUMINUM CULVERT, CAPABLE OF BURIAL TO 10 FT. 2.2 THE 24" PIPE FOR THE LIFT STATION SHALL HAVE A WELDED WATER TIGHT BOTTOM OF THE SAME THICKNESS AND COMPOSITION AS THE CULVERT. 2.3 ALL PENETRATIONS OF THE LIFT STATION SHALL BE WELDED AND WATER TIGHT.. ALL WELDS SHALL BE CLEANED OF SLAG. WELDS ON GALVANIZED STEEL WILL BE SPRAYED WITH ZINC RICH PAINT OR COATED WITH BITUMASTIC. 2.4 THE TOP CAP SHALL BE RAIN TIGHT AND SECURELY FASTENED WITH SCREWS. 2.5 ALL ELECTRICAL FITTINGS AND CONNECTIONS IN THE LIFT STATION SHALL MEET THE REQUIREMENTS FOR A WATER TIGHT SERVICE. 2.6 THERE SHALL BE A HIGH LEVEL ALARM,PEABODY BARNES 6147 OR EQUAL SET AT THE LEVEL OF THE SOIL PIPE FROM THE SEPTIC TANK. THE BUZZER SHALL BE LOCATED NEAR THE ELECTRICAL CONTROL PANEL OR IN A LOCATION DESIGNATED BY THE HOMEOWNER. 2.7 THE SUMP PUMP SHALL BE CAPABLE OF DELIVERING 10 GPM AT A HEAD OF 20 FEET. 2.8 THE SUMP PUMP SHALL BE SUSPENDED NOT LESS THAN 6 INCHES OFF THE BOTTOM OF THE LIFT STATION WITH A CHAIN OR NYLON LINE. 2.9 THE ELECTRICAL CONNECTIONS OF THE LIFT STATION SHALL MEET THE MUNICIPALITY OF ANCHORAGE BUILDING CODES AND SHALL BE IN COMPLIANCE WITH APPLICABLE ELECTRIC CODES. 3.0 SEEPAGE BED 3.1 THE GRAVEL FOR THE BED SHALL BE SIZED BETWEEN 0.5 TO 2.5 INCH AND RELATIVELY FREE FROM SILT OR SAND. 3.2 THE BOTTOM OF THE EXCAVATION SHALL BE RAKED WITH THE BACKHOE BLADE TO INSURE THAT THE BOTTOM HAS NOT BEEN COMPACTED DURING EXCAVATION. THE BOTTOM ELEVATION SHALL BE PLUS OR MINUS 2". 3.3 THE DISTRIBUTION PIPE SHALL BE 4 INCH RIGID PVC OR POLYETHYLENE. THE PIPES SHALL BE LAID LEVEL. 3.4 AN OBSERVATION PIPE SHALL BE PLACED AS SHOWN IN THE DRAWINGS. IT SHALL BE RIGID PVC, ASTM 3033 q-3034. THE SECTION SHOWN WITH HOLES MAY BE EITHER DRILLED' 0.5" HOLES @ 6 INCH CENTERS ON OPPOSITE SIDES OF THE PIPE OR A REGULAR SECTION OF REGULAR PERFORATED 1200 J]Jesl 33rd Aucnue, SuiJe B · AncJmracl¢, Alaska 99503 · (907) 276-1361 DISTRIBUTION PIPE MAY BE CLAMPED TO THE SOLID SEGTION WITH A NO HUB COUPLING OR SOLVENT JOINT. A RUBBER RAIN- CAP (JIMCAP OR EQUAL) SHALL BE PLACED ON THE TOP THE PIPE. 3.5 THE INSULATION SHALL BE DOW EXTRUDED BLUE STYROFOAM BOARD OR ARCO GEOFOAM EMBANKMENT INSULATION BOARD OF THE THICKNESS SHOWN ON THE DRAWINGS. ALASKA ENVIRONMENTAL CONTROL SERVlCE/~!NC. 1.200 West' 33rd Avenu~ ouite B ANCHORAGE, ALASKA 99503 Phone 276-1361 SHEET NO. ' OF ~ CALCULATED BY ~/' ~7~ CHECKED BY DATE DATE SCAL~ Y~r4, /"= Z' h~r,~. I"= ~' ) So;Is' /?~/,',~. 2Z5 (/, ALASKA ENVIRONMENTAL CONTROL SERVICE,~'~NC. 1200 West'33rd Avenue' .,uite B ANCHORAGE, ALASKA 99503 · 'Phone 276-1361 SHEETNO, if~ OF CALGULATEO BY t~f- Z ~ DATE CHECKED BY DATE SCALE CONTROL SERVICES, INC. S.EE~ NO 1200 WEST 33RD AVE., ?-~!TE B I ANCHORAGE ,' ALASKA 9:, - J3 I CALCULATED BY . . PHONE 276-1361 CHECKED BY. SCALE 1, URETHANE FOAM BELOW GROUND 2,..COAT BOTTOM 2 3, USE .~ OR ~ ~ FLEXtB~.E ~..S£E SPECIFICATIONS FOB, DATE DATE . :NOTE S SHOULD BE APPLIED TO A. DEPTH OF 4 SURFACE AT A THICKNESS OF ] INCH, FEET INSIDE WITH_BITUMASTtC PAINT. HOSE TO FIT .PUMP. IV:, AT EP, IALS. FEET .. - .GROUND .LIFT :STAT tON SCREMS.. NEMA 4 BOX- F!LLET WE-LD ~ ALL AROUND> CHAIN OR NYLON ROBE- -PUMP POWER CE No; ~'METAL CAP WITH ~/2" URETHAI:,~E FOAM LLET WmL. AROUND TO 4" COUPLING L~INPT NIPPLE ~.: i_] ~F.~x ~OSE. ' ~¼ C~ECX VA.L.V.E ' suMP- 'pUHp .' -ALARM CORD -] .... ':.4 ':'j STEEL' N:IPPLE"~___J~) (tt PIPE ~ i .. I . __ 1___'_~' ~ METAL :PLATE~ ~ 24* .4 I~OX 1869, STArt I{OI~TE A ANCHOIIAGI!I, ALASKA 9950~ ~.oo DRILLED AT THE RATE OF PER FOOT. .PROPERTY OWNER ~. LOCATION OF WELL SITF DRILLER B~ ~ WELL LOG: 0 .... 16' Sand~ 9.za~e.L ~i.td~ 45~ o~e.t cZa4F. 16---34 ~ Ra. rdpzuz. A c. ea~ ¢.~wed.. Se~e. zaZ 4mad. L ~oudde.~. 34---49' Corw..Lome.za,t~. a L,,ro£e~ ~,ed.,toc~ ma. te~. ~ ~ ~o ~ ~ 49 ~. 49--255' B~o~. a ~ ~ ~~ ~. g~ ~ o~ ~o~ I 1/2 ~2~ ~ 188 ~ 194 ~ ~ a ~ ~ ~ ~ ~ 242 .to 248 ,fd:, ~a,t.e,,r p,,~r~ aL Lou. z gPi?Z ,hz {z ,f..o.t.a,L p,to&Lc~on..~a 5 1/2 ~?~?l. Th,,~ ~LL .oeem.~ ;Lo Th~ /~ed.L wa~ pa. Ld. -foe Zn. 7u~L be ,th.e /flc. Ca~eu~ ,O~ 1984 COST INCLUDES ALL LABOR AND, MATERIAL FOR COMPL~'~ION OF SAID DRILLING. WRITE CHECK PAYABLE TO RAMPART DRILLING WORKS FOR THE SUM OF THANK YOU VeRY MucH. BERNIE CLAUS OF RAMPART DRILLING WORKS DATfS~l~L~2Od~,1984 <~~ SERVICE CHARGE 0 F 1~a% PER MONTH WILL BE: ASSESSED ON PAST DUE ACCOUNT$. ~ ~n On MUNICIPALITY OF ANCHORAGE DIVISION OF ENVIRONMENTAL HEALTH DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION APPLICATION FOR HEALTH AUTHORITY APPROVAL CERTIFICATE 1. General Information Application Data -~/ ~ ~ / (a) Legal Description (include lot~ block, subdivision, saction, township, ranga) Location (address or directions) (b) Applicants Name Applicants ~dress Telephone - Home 5WU' ~-~fi~iness (c) Applicant is (check one) Lending Institution Buyer ~-~; 0ther~__~ (explain); Address (e) Real Estate Co. & Agent Address Telephone (f) Mail the HAA to the following address: Other (describe) Multi-Family~ 2. Type of Residence Single-Family~ Number of Bedrooms 3. Water Supply Individual Well~ Telephone'p~?-1~5% Note: If community well system~ must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Sewag~ Disposal Note: If community well system~ must have written confirmation from the State Departmeut of Environmental Conservation attesting to the legality and status. [Page 1 of 2] 5. Engineering Firm Providing Inspections~ Tests, File Search, Data and Information As certified by my seal affixed hereto and as of the validation date shown below~ I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that, based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site ~mter supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regula- tions in effect on the date of this inspection. Name of Firm Address ;z Date 6o DHEP Approval Telephone Approved for~__~.~ bedrooms Approved~__~.._~ Disapproved Terms of Cond±tional Approval CAUTION THE ~JNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION (DHEP) ISSUES HEALTH AUTHORITY ~PPROVAL CERTIFICATES BASED SOLELY UPON THE REPRESENT- ATIONS GIVEN IN PARAGRAPH 5 ABOVE BY AN INDEPENDENT PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF ALASKA. THE DHEP DOES THIS AS A COURTESY TO PURCHASERS OF HOMES AND THEIR LENDING INSTITUTIONS IN ORDER TO SATISFY CERTAIN FEDERAL AND STATE REQULRE- MENTSo EMPLOYEES OF DHEP DO NOT CONDUCT INSPECTIONS OR ANALYZE DATA BEFORE A CERTIFICATE IS ISSUED. THE Ffu-NICIPALITY OF ANCHORAGE IS NOT RESPONSIBLE FOR ERRORS OR OMISSIONS IN THE PROFESSIONAL ENGINEER'S WORK° (DHEP SEAL) RR4/eJ/D18 [Page 2 of 2] 7-19-84 HE~ilCAL & G~'OLOGICAL LABORATORIES OF ALASKA, INC. 5633 B Street Drinking Water Analysis Repo~ for Total Coliform Bacteria TO BE COMPLETED BY WATER SUPPLIER WATER SYSTEM: LD. NO. (*) See h on back Water System Name City State Mo. Day Year Zip Code SAMPLE TYPE: [] Routine [] Check Sample (for routine sample with lab ref. no, [] Special Purpose [] Treated Water [] Untreated Water SAMPLE NO. I I LOCATION Time Collected Collected By //~' ~"~ TO BE COMPLETED BY LABORATORY Analysis shows this Water SAMPLE to be: Sadsfactory [] Unsatisfactory [] Sample too long in transit; sample should not be over 30 hours old at examination to indicate reliable results. Please send new sample via special delivery mail. Time Received Analytical Method: [] Fermentation Tube ,[~embrane Filter Lab Ref,~ No.Result* Analyst I?~-~ ~ r-Fq ~ I ~ I ~-1 BACTERIOLOGICAL WATER ANALYSIS RECORD READ INSTRUCTIONS BEFORE COLLECTING SAMPLE Membrane Filter. Direct Count Collformll00ml Verification: LTB BGB Final Membrane Filter De,~ulls ReporledSy '~ ~~L..-' Date // ?line: ! INIC = Too Numerous To Count / ~CollformllOOml A. WELL DATA r"-'"~ · "~ MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & MUNICIPALITY OF ANCHORAGE (MOA) ENVIROIqMENYAL P?Off-CTION ~EALTH AU't'~OR.[TY APPROVAL (HAA) I,i/ i? 5 1985 Well Classification Well Log P~esent ~) Date Completed Total Depth ~%~' Cased to Static Water Level r ~.~ Puff Set At Casing Height Above Ground /, Electrical Wit-lng in Conduit ~/N) Separation Distances f~c~ Well: To Se~tic/ll01ding Tank on Lot ; On Adjoining Lots TO Nearest Edge of Absorption Field on Lot To Nearest Public Sewer Line ~J A Cleanout/Manhole Wate~ Sample Collected By Water Sample Test P~sults Cc~aYents ~ F,-~-o ~ TO Nearest Public Sewer Nearest Sewer Service Line on Lot Date 3/t Z./~ 5 ; On Adjoining Lots B. SEPTIC/HOLDING TANK DATA Date Installed 8/i~ /0~1 Size I~oo ¢~,~%\un3 No. of CQ~ga~tm~nts ~ Standpipes ~/N) Ai~-ti~t Caps ~) Foun~tion Cleanout ~) ~ession o~ Ta~ (Y~ ~te ~st P~d N A C~ l~ P~ing~intenan~ ~n~a~ ~ File (Y~)~ ; fo~ ~ ~ Holding Ta~ High-Wate~ ~a~ (Y~) ~ A ~ Holdi~'Ta~ Pe~t (Y~) ~p~ation Distan~s ~ ~ptic~olding Ta~: To Water-Supply W~ To P~ope~ty Line To Weter Main/Se~vic~ CoUrse iOd ? ¥ To Building Foundation ~ To Disposal Field ~' ~ To Stream, Pond, Lake, car Major D~ainag~ Comments ~', ~'rot'. Receipt ~ q~q~? Date Paid: q-i%-~b~ Araoun t: z~_~' ¢30 [Page 1 of 2] 2-15-84 C. ABSOBPTION FIEIZ) DATA Soils Bating in Absorption Date .Installed 9/ Width of Field Square Feet of Absorption A~ea Depression over Field (Y/~ Results of Last Adequacy Test [2~/~ ~Typ~ of System Design Length of Field 5 Depth of Field ~'~ Grail ~d Thick,ss (z" Stan~i~s ~esent ~) ~te of ~st A~a~ Test To Water-Supply Wall TO Building Foundation Lot ~ ~ To Wate~ Main/~.~vice Line To Stream/Pond/Lake/o~ Major D~ainage CoL~se To D~iveway, P~:king A~ea, o~ Vehicle Sto~age A~ea Separation Distance from A~sc~ption Field: To P~ope~ty Line I~' ~ I ~. %~ TO Existing or' ~ndo~d System i~~ .+ To ~t~(if p~e~nt) ~ A bell .w D. LIFT STATION Date Installed Size in Gallons "].~ On" Level at High Water Ala~n Level Manhole/Access (Y/N) "Pump Off" Level at Vent (Y/N) Tested for Electrical Codes(Y/N) Comments Dime ns ions kJ J% Pumping Cycles du~ing Adequacy Test. Msets MOA ** Check Permitted Bedroom Rating Against HAA Bequest I c~tify that I have checked, verified, o~ oonfc~med to all MOA HAA Guidel on the date of this inspection. Signed /~7 ~"~ Date Company /~ { 5 J~ MOA No. 67 KB1/d5/s [Page 2 of 2] 2-15-84 DTIO01?02 i