HomeMy WebLinkAboutSUNSET HILLS WEST BLK 1 LT 7Lo "
.¢IUNIClPALITY OF ANCHORAGE
DEPARTMENT OF HEAL'rH & ENVIRONMENI'AI_ PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street - Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL. SYSTEM AND/OR WELL INSPECTION REPORT
NAME
UPGRADE
MAILING ADDRESS
LEGAL DESCRIPTION
LOCATION
~' I DISTANCE TO', IWell IAbs°ipti°n area
~ Inside I~th
/
~zL DISTANCE TO:
Dweliin9
~ ~ ~ No of lines Length of each Ibm
I ~ ~'~~ ~ ~ ~d~ ~ Material beneath tile
~ Top of tile to finlsh grade
NO, OF BEDROOMS
Dl~elling .... PERMIT NO.
Material No. of compartments
Liquid depth
PERMIT NO.
Liquid capacity in gallons
PERMIT NO.
Material 19 ~IZ
Nearest lot line
Trencl~ width
"~ ~) illches
[ Length Width
I ~(~f crib Crib diameter
DISTANCE TO: Well
Class Depth
~llS~ Building foundation
OTHER
PIPE MATERIALS
SOIL TEST RATING
INSTALLER
Total effective absorption area
10 F~r.~'~'~ ?~L4O_~.~TZCf~_¢_¢_,_ ____
PERMIT NO,
Crib depth Total effective absorption orca
Building foundation Nearest lot line
Driller Distance to lot line / PERMIT NO,
Sewer line Septic tank ] Absorption area(s)
REMARKS
~ , No. ~oa-~
APPROVED ~J '~' · ,~ 0~.~ ~~ DATE
LEGAL
/G .--
........................... I ~ .L
Yro:~s-d Ir, stalla':~,n--~uepage Pit ~ ' Drain Field
Desert Of ~,,1-. l)eptn '/o Bottom Of ~fit Or 'french
~~--~"~ .......
Data Ce~t}.flcd
D-
R&M
Civil Engineers
ENGINEERING & GEOLOGICAL CONSULTANTS
229 EAST 51st. AVE. - P.O. BOX 6087 - ANCHORAGE, ALASKA 99503
TELEPHONE 907-279-0483 TELEX 090-35419
Geologists Land Surveyors
JAMES W. ROONEY, P. E,
MALCOLM A. MENZIES, P.E., L,S.
JAMES H, WELt. MAN, P.E.
RALPH R. MIGLIACClO
Eilglneerlng Geologist
June 4, 1974
R & M No. 461007
McClurg Enterprises
3106 East 84th Avenue
Anchorage, Alaska 99507
Attn: Mr. Dave McClurg
Re: Lot 7, Block 1, Sunset Hills Subdivision, Sanitary Sewer Backfill
Material
Gentlemen:
In response to your request an inspection was made at subject site for
the purpose of identifying and sampling granular backfill material
placed around the seepage pit. A collected sample was returned to our
testing laboratory and the grain size distribution is reported on the
attached form.
A single test pit was excavated to a depth of six feet immediately
adjacent to the concrete ring and a combined sample was collected from
the vertical length of the exposed granular backfill. The backfill
material was identified as a well graded sandy gravel (GW) containing
a trace of silt. As indicated, the silt size particles for the recovered
sample were measured to be 5 percent passing the #200 sieve.
While the above gradation borders closely to a slightly silty sandy
gravel (GW-GM), we do not feel that this material will have any detri-
mental effect on the performance of the seepage pit.
Should you have any questions regarding the above, please do not hesitate
to contact us.
Very truly yours,
R & M ENGINEERING & GEOLOGICAL CONSULTANTS, INC.
Vice President
JWR:ph
Attachment
ANCHORAGE FAIRBANKS JUNEAU
TEST ON Classified Backfill
PROJECT NO, ,PROJECT NAME--McClurg Enterprises
SAMPLED FROM Lot 7 Bk 1 Sunset Hills S~U~UBMITTED BY Duncan
SOURCE. Sandlake Aggregate Corp Pit Kincaid Road
LOCATION Anchorage, Alaska
GRAIN SIZE DISTRIBUTION
%PASSING
SIEVE
DEPTH.
0-6' DATE SAMPLE[) 6-1-74
CLASSIFICATION
UNIFIED AASHO FAA
#4
-f/-s CLASS GW
# ~o
#4o
#DO
STATIC IMMERSION
BRAND, 0% --. I/Z°/o--
DELETERIOUS MATERIAL SPEC FINE
MINUS ~'~ 200 MESH
ORGANIC COLOR
R~M PROJECT NO. 461007
LAB NO, 73A-474
FIELD NO. FS#1
DATE REPORTED 6-3x74
DATE RECEIVED 6-1-74
COMPACTION
MAX. WET DENSITY __
MAX. DRY DENSITY
CORR· MAX, DRY DENSITY
% FRACTURE
METHOD
NATURAL DENSITY- __
NATURAL MOISTURE ......
WEIGHT LOOSE--
WEIGHT RODOED ....
MOISTURE - PERCENT
F~V[ Englnesring ~(3eologlcal Con~ultont3
· 06B372
QGRE,~
~R ANCttORAGE AREA BO~' "~GI~I
Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
LOCATION
_ MAILING ADDRESS -~/(,*/'-)- ;~"/'//,~ _ PHONE
SEPTIC TANK:
DISTANCE
FROM WELt_ /~0'
INSIDE LENGTH
MANUFACTURER
INSIDE WIDTH
MAT E RIAL (/~ ~P/VfJ~:'~' ~f ~ _
NUMBER OF
COMPARTMENTS
LIQUID DEPTH ~- LIQUID CAPACITY //~'->(-) ,GALLONS.
SEEPAGE PIT:
NUMBER OF PITS / DIAMETER OR WIDTH ¢~/./ LENGTHen,/ DEPTFI ¢ /
LINING MATERIAL ~//~'~ CRIB SIZE: DIAMETERJ~ DEPTH~ /DISTANCE FROM: WELL~2~
";- X '
BUILDING F'OUNDATION~~(~ ( NEAREST LOT LINE O'-/' TOTAL EFFECTIVE
· ABSORPTION AREA (WALL AREA)
SQ. FT.
ADDITIONAL ABSORPTION
WELL:
TYPE ~/~? f,,.(~Li', __CONSTRUCTION d~ A.-
r DEPTH
BUILDING NEAREST NEAREST SEPTIC
FOUNDATION LOT LINE SEWER LINE TANK
CESSPOOL OTHER SOURCES
APPROVED DISAPPROVED REMARKS
DISTANCE FROM:
SEEPAGE
SYSTEM
BISTANCES: /,? ~
LOT SLOPE:
RFMARKS:
Form No, EQ-031
DIAGRAM OF SYSTEM
APPROVED
GREATER ANCHORAGE AREA BOROUGH
DEPARTMENT OF ENVIRONMENTAL QUALITY
pERMIT NO,
SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMI'T
INSTALLATfON OF': SEPTIC TANK
TYPE AND SIZE OF FACILITY TO BE SERVED
FINANCED THROUGH
,oil T sT RES"I_TS
SEEPAGE PIT__ r'~ _, DRAIN FIELD
., OTNER
NOTE: THIS PERMI'r IS NOT VALID wrrHOUT SOIL TESl'
~v
WELL TO SEPTIC TANK - /CO ., SEEPAGE PIT ,~O0
SEPTIC TANK, ~OD/ SEEPAGE Prr /¢ O , DRAIN F[ULD
CAST ]RON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF
GRAVEL BACKFILL
CONFORM 'to BOROUGH REGULATIONS REGARDING INSTALLATfON.
TYPE
~-I~/__
CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ,~rHE/~E
ANCNORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE BOVE
~i-'0 ~h ULIN I C I PA L 1 1Y OF ANCI IORAG E
// .~..}e'a~ ~ ....
~;,~, I}EiU~RTMEN. Jk HEA[.TH AND _HVIRONPIENI
DaLe Received:
dlOT[i C T 1 ON
9950I
Lend J.n g
Mai'ling Address:
Property OWl'leU:
Mai. ling Address:
3. [,ega]
InsLitul:ion Requesu: First National Bank of Anchorage
Pos% Office Box 720 99510 Phone: 276-6300
D./Barbara J. Bennett ~2 ............ Ihone:
% Clyde Lower, Jack White Company 277-1553
Descript.~on: Lt 7 Block 1 Sunset Hitls~ubdivision
Single ~.ara_L]y Residence: (x)
Multiple Family
Number of Bedrooms: Three
Nurnbor (Df RedY'loms:
We].l Syseem: .l. ndividta] Wc].]. (x) Co[mnunxty/l'ubl.i.c Sy. t.m
Permit ,, l)epth of Wel.1 }VEIN Log :}n I;'J].e
Construction Bac. i_e~ 1 ti Analys~s
{ /
Sewage Dispesal Sysucm: On--site System (x) Public Uti] [ty
Permit "- ................ Instol] ed __3~_~_~ ........ Instal. lot ...[~[~-g.x~__~
z - ~ Mimufac'turer . ~D~t~.J{--.
Septic Pank S~ze .... ~3_~,:~:1~ .... ~
Absorptzon Area _333~_~ ...... Soils Rate ,' Material
.... ~ZX~ ..............................
7. Distances: Wel.l. to SeptJ. c 'J'ank ~:c Al')sorpu:Lon area .................
cc) Nearest Lot Line
Page
Reque,~.,'t tot Apl~rova]
llc~al kh and ~,nv~.ronm~:.nL, .I. Pvot':~cl ion
Affadavit Attached: ( ) i,et'La~]7 At:tachecl: ( )
Appr ovecl: ......................................... DaLe
D J. sapproved: ................................... l)ake:
Department Worksheek:
1. Type of Inspection:
2.
MUNICIPALIry OF ANCHOkAGh
MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION ENVIRONMENTAL PROTt~CiION
825 L Street, Anchorage, Alaska 99501
279-2511, ext. 224, 225
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER and WATER FACILITIES
VA
NOV 9 1977
FHA__CONV
· Property Owner:_ BENNET]?, D. & Barbara J.
c/o Clyde Lower
Mailing Address: Jack White Cs., 3201 C St.
Day Phone:
277-1553
3. Name of Buyer:
I~myne L. Melchert & Joyce M. Melchert
Mailing Address: 411 Eqavik Drive Day Phone:_ 272 6057
4. Name of Lending Institution:_ The' First National Bank of Anchorage
Mailing Address:____P' O. Box 720, Anchorage, Ak Phone: 276-6300
5. Name of Realtor or Agent:. Clyde ~ower, Jack Nhite Company
Mailing Address:_ 3201 C Street, Anchorage, Phone: 277-1553
6. Legal Description: Lot 7~ Block 1~ Sunset Hills West
Location: 14321 Jarvi Drive, Anchorage, Alaska
7. Type of Facility to be Inspected:
8. Water Supply
Type of Supply:
residence
No. Bdrms..
Public Utility_
.Individual.
well
If Indi~ ' '-"~ number of dwelling~ presently served
If Individual, depth of well
Sewage Disposal System
Type of System: Public Utility
If Individual, date of installation
1
septic tank
Individual (on-site)
72-003(3/7O)
/do
December 28, 1977
First National Bank of Anehorage
Post Offico Box 720
Anchora~[e, Alaska 99510
Attention~ Inge
SubJeot~ I~t 7 Bloak 1 Sunset Hills We~t ~.,ubd. ivision
[)./Barbara J. Beanett Proper~y
The adequacy test of fha existing sewer sy.~te~ failed°
jfl~-~epartn~e~%t~¥;'lll grant a ~onditional ~proval if
~lds are ?scrolled to upgrade th~ absorption area by
~lmspe~LOatlon,~ for tho upgra<lo arc a~ follows:
Option
Absorption Trench ,- Lenghh, seventeen(17) fe~t
Gravel backfill ~epth,
ten(10) feet
Total depth w~riabl~
Option
Absorption Treneh- Length, thirty(30) feet
Gravel backfill depth,
six (6..) feet .
'~:otal f%epth w~r~able
If the. l~e are any fuz'ther questions, plaago contact this
office at 264,-4720.
Sincerely t
~'~s N. Buchholz,
ICenior Environmental Specialist
LNB/lJh -