HomeMy WebLinkAboutSUNSET HILLS WEST BLK 2 LT 1 GREA,! ANCHORAGE AREA BORe Department of Environmental Quality 3500 Tudor Road Anchorage, Alaske 99507 3H INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM /"-'~ -- /¢/~ O./¢L': MAILING AD DRESS ~/~ Z/~, SEPTIC TANK: DISTANCE .~ /) NUMBER OF INSIDE LENGTH_ ~ INSIDE WIDTH ~ LIQUID DEPTH__*"~ LIQUID CAPACITY/¢2~'1~ GALLONS. SEEPAGE PIT: / / LINING MATERIAL __~~.~.~: DIAMETER____DEPTH. DISTANCE FROM: WELL/ X_ TOTAL EFFECTIVE / BUILDING FOUNDATION , NEAREST LO1:"'~NF~.. , ABSORPTION AREA (WALL AREA) / SQ. FT. ADDITIONAL. ABSORPTION __ ~--., / WELL: TYPE ~Jq¢ ~£4'~ CONSTRUCTION DEPTH BUILDING "~"~~ NEAREST SEPTIC SEEPAGE FOUNDATION , LOT LIN E--"'--'----"--~-~F..~ , TANK_ , SYSTEM_ CESSPOOL , OTHER SOURCES APPROVED DISAPPROVED REMARKS DISTANCE FROM: DISTANCES: INSTALLED BY: PIPE MATERIAL: LOT SLOPE: REMARKS:_ g~' Form PW-02a G.A.A.B. C~ GREATER ANCHORAGE AREA BOROUGH PERMIT NO,- SEWAGE DISPOSAl. SYSTEM -- APPLICATION AND PERMIT OTHER - NOTE~ THIN PERMIT lB NOT VALID WITHOUY SOIL TI~ST INSTALLATION LOCATION LEGAL DESCRIPTION ~ TYPE AND SIZE OF FACILITY TO SE SERVED .-~L~J~/~/~I __~/V~; ~-~/~' ~--~l TO BE INSTALLED BY FINAL INBPECTION~ ~4 ItOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPEC.¥10N BY THE HEALTH DEPARTMENT AUTHO~I~ WILL. BE ~UBJE~T TO PROSECUTION. MINIMUM DIBTANCES. REQUIREMENTS 5 ft. FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PiT . 20 ftc DRAIN FIELD ~].0 SEPTIC TANK TO SEEPAGE PIT WAlL ~[~ (~' e .... WElt. TO SEPTIC TANK __ J~ SEEPAGE P~ ~ ~ DRAIN FIELD ALSO CON~IDER AREA WELLS WATER MAIN TO SEPTIC TANK ~ SEEPAGE PIT ~0 ~00 TO RIVER, ~AKE, STREAM. -, t~RAIN FIELD ~.0 ft. GF DEP~ ~TER ANCHORAGE AREA BOROU~ MENT OF ENVIRONMENTAL QUAL,TY CASE #_____~_ 3500 TUDOR ROAD ANCHORAGE, ALASKA 99502 6910 Performed For Western Enterprises , . Date Performed_ 8/30/72 ~ Legal Descript-'Tb-~-~--r- B-g]o-~-k- 2 Subdlvl~ion ,89ns~tHills ,__ This Form Reports Soils~g 5~-- Percolation Test__ Depth ,Feet Soil Characteristics 2 , 3 ~ 4 ~ 5 ~ 6 7 8 ~ 9 ~ ~0 ,, Ogang'e red silt (ML) Silty sand (SM) Silty gravel (GM) S~ndy gravel (dW~ Was Ground Water Encountered? If Yes, At What Depth? Reading Date Gross Time lO[lnute Net Time Depth to H20 Net Dro Proposed Instal-T'~-t-lon: Seepage Pit x Drain Field Depth Of Inlet Depth To Bottom Of Pit ~l'renc~---~, COMMENTS: 85sq.£t. per---b-'Cdrodmatadep--~hbelow4foot. ~ Te s t Pe rfp rme d ' By ?itz_p~trick Date: ,TER ANCHORAGE AREA B 'OUGH Department of Environmental Quality 3500 Tudor Road Anchorage, Alaska 99507 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM ~¥~' SEP-T+6-T A N K: DISTANCE FROM WELL'~J ~ , MANUFACTURER INSIDE LENGTH INSIDE WIDTH_ NUMBER OF MATERIAL ~'~'~ I~O t~__ COMPARTMENTS__ I _ LIQUID DEPTH__ LIQUID CAPACITY_ GALLONS. SEEPAGE PIT: NUMBER OF PITS DIAMETER ___ OR WIDTH__, LENGTH DEPTH -[JNING MATFRIAL ~CT~ SIZE: DI~*ETE'R----DE~LTI4~- ~[21SZ~CE FROM: WELL TOTAL EFFECTIVE BUILDING FOUNDATION__ NEAREST LOT LINE____. ABSORPTION AREA (WALL AREA) __.SQ. FT. ADDITIONAL ABSORPTION ___ WELL: TYP~_,Y~, [.~A"~"'~'~r~ CONSTRUCTION BUILDING NEAREST FOUNDATION LOT LINE CESSPOOL OTHER SOURCES_ APPROVED __ DISAPPROVED DEPTH DISTANCE FROM: NEAREST SEPTIC SEEPAGE SEWER LINE TANK SYSTEM REMARKS DISTANCES: INSTALLED BY: PIPE MATERIAL: LOT SLOPE: __ REMARKS: Form PW-026 DIAGRAM OF SYSTEM I I~/ G,A.A,B, GREATER ANCHORAGE AREA BOROUGH SEWAGE DISPOSAl. SYSTEM -- APPLICAI'ION AND PERMIT , OTHER NOTE~ THI~ P£1~MIT IS NOT VALID WITHOUT BOIL Ti:ST , . PFRM_i.T__V. ALLD_.ONLY_EAR i .~ FINAL INaPEGTION~ 24 HOUR NOTICE: REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL IN~PEC'rlON BY THE FOUNDATION TO SEPTIC TANK '~ FOUNDATION TO SEEPAGE PIT ~0 ~:t, DRAIN FIELD SEPTIC TANK TO SEEPAGE PiT WALL WELL 1'O SEPTIC TANK---- , SEEPAGE PII _ DRAIN FIELD .... ALSO CONSIDER AREA WELLS. WATER MAIN TO =SEPTIC 'rANK 10 f~' SEEPAGE PIT ~0 SZPT~C TA.~, 25 f%.. S~EPAOE ,,T .100 ft. DRAIN FIELD ~0 TO RIVER, LAKE, STREAH. CAST IRON INTO AND OUT OF SEPTIC TANK AND ]NTO CRiB CROSSING GAP OF