Loading...
HomeMy WebLinkAboutSTUART Lots 1 & 2 Plat# 98-58 S-10206 MUNICIPALITY OF ANCHORAGE COMMUNITY PLANNING AND DEVELOPMENT P.O. Box 196650... Anchorage, Alaska 99519-66S0 PRELIMINARY PLAT APPLICATION Please fill In the Infon,natlon requested below. Print one letter or number per block. 1. Vacation Code 2. Tax Identification No. 3. Street Address ' OFFICE .USE REC'D BY: 4. NEIlII abbreviated legal description (T12N R2W SEC 2 LOT 45 OR SHORT SUB BLK 3 LOTS 34). L~I4~I 1~l~l,14el~l~l 1.1,1414,1~J.I 1~,.4 IIIIIII /I IIIIIIIl-IIIIIIIIII/ll/I 5. ExI~rlNG abbr~viated legal des~rlptlo~ (T12N R2W SEC 2 LOT 45 OR SHORT SUB SLK 3 LO;~'S 3~')'~fUii'l~al on back page. LIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 6. Pstifloner's Name ([.ant- Flint) ....... 7; Petitioner's Representative ~'- ~ IMitj t, ler ~, ~,: 't" 4 4 El I I I I I I IIIII / IIIIIII IIIII Address P.o. Box 771747 Address (3~_Eaqle River S~le Ak 99577 . C~. ' Phone#907-694-7112 Zip 99577 Phone# II 8. Petition AmaAcreage ~1.1/1~1 I I I IIIIIl_l 9. Proposed 10. Existing Number Lots Number lots 11. Grid Number ~_lq I~lzl I IIIIII 12. Zone H +t 13. Fee $_ 14. Community Council B. I hereby cerllfy that (I am) (I have been authorized to act for) the owner of the property described above and that I desire to ~ubdivide it in oonformancowith Chapter 21 ofthe An~omge Municipal Code of Ordinances. I understand that payment ofthebaslosubdlvision feels nonrstundable and Is to cover the costs associated with processing this application, that It does not assure approval of the subdivlSlon, lalso understand that additional fees may be assessed if the Munlcipality's costs to process ti'ils application exceed the basic fee. I further understand that assigned hearingdates amtentative and may haveto be postponed by Planning Statfl Platting Board, Planning Commission, or the Assembly due to administrative reasons. Date: Signature *Agents must provide written proof of authorization. MEMORANDUM DATE: April 16, 1998 R [ C [ IV E D TO: Jim Cross, P.E. AP[:I ] (~ 1098 FROM: Mike Anderson, P E ~ ~0,.- Muni'c,pality of Ancho[age . . Dept. Health & Human Services SUBJECT: Lots 1 and 2, Stuart Subdivision S- 10206 Attached is a drawing of the proposed Stuart Subdivision showing the location of the septic system reserve areas. These areas encompass 12,000 square feet in m'ea based on percolation rates of 3 minutes to 11 minutes per inch which were achieved on the soils encountered in the testholes on the lots. The reserve area for Lot 1, Stum't Subdivision is hampered by the location of the well on Lot 1 of Section Lot 11 immediately to the north. This well was apparently placed without a permit after the construction of the septic system on Lot 1 of Stuart Subdivision. We have located the reserve area out of the 100' protective radius of this well. The well currently on Lot 1, Stuart Subdivision will eventually be relocated to the front of the lot. It will then be mom than 100' from any portion of the septic system reserve m'ea and from any septic system in the area. Please review this drawing and advise if you have further questions. [ have also enclosed the Summary of Action for this subdivision. If you tu'e in agreement with the locations of the reserve areas please initial Item No. 4 with your approval. Thank you for your cooperation with this matter. ;,minimum PERFORMED FOR: LEGAL DSSCRIPTION.'T.o~ I 7 8 9 10 11 '12 13 14 I;; 16 17- 18 19- 20- · Munl~pality of AnChorage 825 "L" Street. Ancl~erage, Alaska I]9502~850 't~ e,~;.'..~:,~.n :;~~ ,. · ' :~.' ~ Stuart Gilbert , ' __ DATE PERFORI~II~/O/~'~ COMMENT~ Township, Range, Re=tion: SLOPS WAS GROUND WATI'~I ENCOUNTERED? IF YE~, AT WHAT DEPTH~ SITE PLAN PF. RCOLAllON RATE // ~,mmute~;nch) FERC HOLE DIAMETER ~ '.__~ ~oo,D^.o, ~,.. A.. ~^,~ A.D MU.,C,FA~ GU,D....,. ~=:' O...,-" ~A,~ D^~"' ' /~'/~ ~ (Rev, 4185! Munl~lpalilV of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 $OI1.$ LOG ,-- PERCOLATION TEST PERFORMED FOR: Stuart Gilbert DATE lEGAL DESCRIPTION:Lot I R .1 ~,. $. 8- GM 9- 20- COMMENI~ R1 2 .T1 4N.R2W Township, Range, Section: SLOPE SITE PI.AN WAS OROUND WATER ENCOUNTERED? NO Gro~ Net Raedlng ~ Time Time Wirer Drop -~1 ,zll J97 /~ ~ - II ,, _ _~ ~:~4 ~- IZ,l~, I~/~', PERCOLA'rlON RATE '-~ (m~nutes,'lnch) PERC HOLE DIAMETER 'TEST RUN SS3WEEN ~,~,,,~ FT AN D ~ .FT (Rev, 41851 IN Munlidplill,/of AniJtlorage DEPARTMENT OF HEALTH & HUMAN SERVICES 625 "L" Street, Ancltomge, AIf~I~ 99502-0650 8OILS LOG --. PERCOLATION TEG'T PERFORMED FOR: Stuart Gilbert CEGAI. DESCRIIr'flON:Lot'- 1 8 ~1 2 .T1 4N,R2W 1 2 3- :12 - I'~- 15- 17- '~0'ITOt'~ 0 ~ ELOPE SITE PI.AN WAS GROUND WATER . EnCOUnTF.~EO? ,~o IF ¥1~. AT WHAT ~' DEPTH? ~ pO E IllIMtld~t L~ ACCORDANCE ~TN a~ ~A~ AND MUNImP~ aUlDmNB IN EF~ ON ?HI8 OAT[ DA~ 1/~/~ , P~IDC}].ATION ~TE /~ (mmut~nfl~) pE~C HOI.E DIAME'~R /~" I~'~T RI, IN BETWEEN /~ irt AND 5-- FT Dam Gro~ Net ~ m N~ Time . ,~J~v ~:sa - ~/w, ~:~7 , ~ /1~10. / ?/~,, ~;/~- ¥ ' I~ I ~ II 'A~" I ~/~" 50] ~// (~78o97 STATE) / ~ ~' N OOQO$'37"E 279,07' (MEA$) / PROPOSED LOT LINE N OOe(~6'35"W 280.~' (MEAS) [ ~80,20 (STATE) o~ "1 LOTS I & 2, STUART SUBDIVISION SEC, LOT I~' SEC, LOT 17 -- $~'e9"55' $~9,76' WFJ..L 0 ' 0 L TH ~ 1 .... ~/ELLy SEC. SEC, EAGLE RIVER ROAD SEPTIC SYSTEM RESERVE AREAS SCALE 1" = 100' April 2, 1998 Municipality of Anchorage Department of Heath & Human Services 825 "L" Street Anchorage, AK 99502-0650 Attention: Jim Cross, P.E. R cCEIVED APR 2. 1998 Municipality of Anchorage Dept, Health & Human Servioo~ Subject: Stuart Subdivision - Lots 1 and 2 S - 10206 Water Availability Study Dear Mr. Cross: I have recently completed a study of the lots surrounding the proposed Stuart Subdivision to determine the depths and production rates of the wells aud overall water availability and quality. The results of the study indicate the majority of the wells are betweeu 80' and 150' deep and produce water at rates from 6 gallons per minute to over 20 gallons per minute. Water quality tests taken in 1997 on Lot 17 of Section 12 indicated no coliform or other bacterial and 1.93 mg/L of nitrate coutent. Similarly the water on Lot 18 was found to contain no coliform or other bacteria aud 2.43 mg/L of uitrates. Both wells am approximately 80' deep and were drilled in the early 1950s. The shallowness of the wells could account for the minor amouut of nitrates fouud. Lot 18 of Section 12 is the subject parcel for this subdivision. It will be split in two equal parts to form Lots 1 and 2 of Stuart Subdivision. The well currently in place will serve Lot 1. This well is 80' deep with casing to the bottom. The well has beeu in place since the early 1950s. Some modifications to the well head will be required to bring it into compliance with curreut requirements. The owner of the lot has indicated these repairs will be made this summer when conditions am better. We am hopeful the subdivision call be recorded prior to these repairs being made. In general it appears that the well to be placed on Lot 2, Stuart Subdivision will be between 80' and 150' deep and can be expected to prodnce at least 5 gallons per lniuute depending on the depth aud level of development. The quality of the water should meet or exceed curreut drinking water requirements. Backup documentation concerning other wells in tile area are included for your review. know if you have any questions. Sincerely, Michael E. Andersou, P.E. Attachments Please e~ me