HomeMy WebLinkAboutT15N R1W SEC 8 LT 25 Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP211001 PID Number: 051-092-30 Dwelling: ❑■ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New 0 Upgrade Name SANTIAGO JONATHAN JAMES AORPTION FIELD ❑ D Trench El Wide Trench El Bed El Mound Site Address 20805 S Birchwood Loop Rd Other Phone Number of Bedrooms Soil Rating Total depth from original grade 4 D/SF Ft. LEGAL DESCRIPTION Depth to pipe invert from original ode Ft, Gravel depth beneath pipe Ft. Subdivision Block Lot 25 Fill added above original grade Ft. G el length Ft. Township Range Section T15N R1 W SEC 8 Gravel width Ft. Beds: Number of Lines Dis ce between lines Ft. SEPARATION DISTANCES To Septic Absorption Holding Sewer Total absorption area Number of trenches Dist. between nches From Tank Field Lift Station Tank Line Ft2 t. Well > 100' na na na > 100' TANK 0 Septic [IS.T.E.P. ❑ Holding El Other Manufacturer Capacity Greer 1500 Gal. Surface Water > 100' na na na Material plastic Number of compartments 2 Lot Line > 10' na na na NA Foundation > 10 na na na LI STATIONManufacturer Capacity Gal. Remarks Alarm location Electric ' Ile d by PIPE MATERIAL House to tank 3034 Tank to 3034 drainfield Installer JRs Septic Drainfield CO/MT3034 Inspector Curtis Townsend BENCH MARK (Assumed elevation) 100 ft Inspectiond151 7/2/2021 Z„d 10/8/2021 Location and description top of concrete retaining wall 3b 4°i ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp *X Date �°'�I A Aw Conditional Approval: -:�%!Wk co AQ TH . ............... Curtis L T wns . Date 10 It • W 110 Septic Syste / App veld' Date 2� ve No. CE 11904 ����F�PROFE5510NP4e�� Note: this approval does not include well permit requirements. (Rev 05/02118) 1982 WELL, 160' DEEP 1985 WELL, 208' DEEP 00 0 a _ cn p C� m mDRI VEWA Y SUMP m I O SLOPE FLAT I A o III l septic \ EXISTING 42' x 56" x 6' EFFEC TI VE DEPTH TRENCH ASF DECK SUPPORT' " BM TYP NEW SEPTIC TANK �I r� m HOUSE SCOPE OF WORK 1. REMOVE EXISTING SEPTIC TANK. BACKFILL SEEPAGE PIT. 2. NEW 1,500 GALLON PLASTIC SEPTIC TANK DRAINING TO THE EXISTING ABSORPTION SYSTEM. THE TANK WAS PROVIDED WITH MINIMUM 20" 0 MANWAY RISER SERVING THE FIRST COMPARTMENT. DOUBLE CLEANOUTS WERE INSTALLED AFTER THE TANK. A FOUNDATION CLEANOUT WAS PROVIDED. 3. ALL CONSTRUCTION WAS IN ACCORDANCE WITH ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65. LOT 24 I LOT 23 LOT 26 NEIGHBORING SEPTIC IS > 10' FROM PROPERTY LINE X100, mow` tv w 1985 WELL �w LOT 26A 100' 1982 WELL CASING WAS \ STRAIGHTENED � NEIGHBORING SEPTIC IS > 70' \FROM PROPERTY LINE \ KRYST L LANE SPECIAL PROVISION SCOPE OF WORK 1. 1982 WATER WELL WAS CONNECTED TO THE HOUSE. 2. THE THIRD WELL ON THE LOT WAS LOCATED AND DECOMMISSIONED. LOT 39B Record Drawing Prepared for 1, JONATHAN SANTIAGO `��P�. OF q4�s��`o 20805 Birchwood Lp Chugiak Ak 99567 ' %��� T15N R1 W SEC 8 LT 25 . �} TH 4 AN.....'........:......0 .. OSP211001 AN �.............. ..............................10 EKLUTNA ENGINEERING, LLC DATE: 10/11/2021 �#=;CURTIS TOWNSEND:�� �� No. C 11904 '19162 MOUNTAIN. ROAD DRAWN: CLT •� / 0/,I���r�,: CHUGIAK, ALASKA 99567 SCALE: V, = 50'�♦4�. ""..SS\ —0 .. .0 (907) 406-1058 44' PID: 051-092-30 SHEET 2 OF 3 z Z `� I— W N mZ m—,Q MARK A B ST1 20'-3" 21'—l" ST2 23'-8" 24'-5„ DCO 25'-8" 26'-i" Record Drawing Prepared for DECK SUPPORTS ARE DRIVEN STEEL PILES. THE PILES ON EITHER SIDE OF THE TANK ARE > 5' FROM TANK. THE BOTTOM OF THE PILE NEAREST THE TANK IS BELOW THE BOTTOM OF THE SEPTIC TANK. THE TANK DOES NOT PENETRATE THE SOIL BEARING PRISM OF THIS PILE. JONATHAN SANTIAGO 20805 Birchwood Lp Chugiak Ak 99567 Tl 5N R1 W SEC 8 LT 25 EKLUTNA ENGINEERING, '19162 MOUNTAIN ROAD CHUGIAK, ALASKA 99567 (907) 4-06-1058 OSP211001 LLC DATE: 10/11/2021 DRAWN: CLT SCALE: 1" = 5' PID: 051-092-30 SHEET 3 OF 3 OF ..... �C�S°�®� ®........................................:...... 0 0 , 0 ® ..............................................0 CURTIS TOW NSEND tZi- Ar ®�� '• No. CE 11904 •••._...........klilklAS ®® 01-p-, ME / 1.9 fl =�a zNm \ a� t C or > A / m 9p \ O £O A 1 M) G) @ CD p ' 1 A 3 OD 3 / LLn W \ .� — 3 m m 3 �\ _� ml PA -acnz Ip, z ti Z m e~ h d � o � Ip op 4p, / p - < 02/ v N o (W) ,b9'6IEI Qd❑a cl❑❑-I (100/MH3IdE1 S m Chi WIg) ,99'OZEI /'Mr00,S0vOON Npd •0'M•b 6l�2 6d 291 N8 anaasaa lmn/ orpoob }ua}.nd .09 F- 0 W OW N Cf] M Nn hh E>n H co o =�a zNm \ a� A ZZ C v > A A\ m O £O A COX G) @ CD ` A 3 OD (�D co • mn m W m o. � — 3 o� 3 zn N� _� a -acnz C4 V O py 'DVW N \� N O N ` � S0 � n hA m n r I . c o TT I DD -A D r � � O r X � �N0� Q t D Z, x �caC:91 M f s �=r w ' m s 3 w co o o N O N C,QNC rcno m C) °� v° zn < O 3 AA O N �Co NK a. A O< A \o � _ rn m 1 •0'M•b 6l�2 6d 291 N8 anaasaa lmn/ orpoob }ua}.nd .09 F- 0 W OW N Cf] M Nn hh E>n � Q «f WIg) 102'0££ 3 rOE,70.00 S o =�a zNm \ a� o - v E00 (a <21 W�8) OZ'OEE -00, 3 COX ` 3 z OD c, mn m W o� h �} n =1 9On _� a py 'DVW N N O N hh � S0 n hA I . wm M- ON D � � n Q t 3 / s � Q «f WIg) 102'0££ 3 rOE,70.00 S o =�a a� o - v tcl 3 � Q «f WIg) 102'0££ 3 rOE,70.00 S Municipa%c of Anchorage Community Development Department Ori-$Tte Water and'Albsteaater Program 4170 Luno c, 8t. - P.C. Box 196650 Anch,:)rage, AK99519-6650 + llttp�-P4vk%�%v.muni-orgionse - (E-07) 343-704 L,,-q;!l oda Irr--.a: Subdivision Block Lot T 1 RR, Section Lot r1 f),-4-rhn & va"irray.4amr Pmr-,r7.rr, e.-x-r'ifx,-ft rartzm-rr r4).-tf;-rt-.rn:l rm- m -t dtbm,-rTuL--;mrimj: PNO dectaftf:mlonirp date AMC 15.55.06OLl a.71 b.71 r—mv luv�liw. Utie the scga-r- LvtLk�w k., vuesj,� a 61 Of Ily-' P'D--ttvVICTAil-I'4 111-4 r0baw',iII4 items. No7n a7m* '71n:, -,:7 m Tm i 5 Si r -n,.! 0 vs,- r' N.JIL-T w -AN a -I I wo -,,_Pafafe 3srs7 ti= di.-�1notIL trwar YVIA Mwon 00 CIE. dravoring. Noftt; The!;Mrr _4 lit! cibsiarrx.,.stall he rill - r lei MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP211001 Work Type: SepticTank Upgrade Tax Code Number: 05109230000 Site Legal Address: T15N R1 W SEC 8 LT 25 G:1357 Site Mailing Address: 20805 S BIRCHWOOD LOOP RD, DUPL, Chugiak Owner: MCEWEN MELVIN L & ILENE B Design Engineer: EKLUTNA ENGINEERING, LLC* This permit is for the construction of: Effective Date Expiration Date Lot Size in Sq Ft: Total Bedrooms: Depai-mient 1/12/2021 1/12/2022 108900 ❑ Disposal Field 21 Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: 1. The Record Drawing is to confirm that the 1982 well has been connected to the house. 2. The Record drawing is to address the third well on the lot. Received By: Date: Issued By: Date: 2 Z 4 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 051-092-30 Property owner(s) MCEWEN MELVIN & ILENE Mailing address 20805 Birchwood Loop Chugiak Site address 20805 Birchwood Loop Chugiak Day phone AK 99567 AK 99567 Legal description (Sub'd., Block & Lot) T1 5N R1 W SEC 8 LT 25 Legal description (Township, Range & Section) Lot Size 108,900 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) ❑ (w/wo ADU) Septic Tank M Upgrade Q (D) ❑ Holding Tank ❑ Renewal ElDuplex Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the abov information is correct. I further certify that this is in accordance with applicable Municipal o0es. (Signature of p owner or authorized 2,o -z f Permit/Rush Fees: $225 Waiver Fees: Date of Payment: 111 d, Date of Payment: Receipt Number: 0 1 0 3 3 b Receipt Number: Permit No. OSP211001 Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client FonnsTermit Application.doc Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211001, Deb Wockenfuss, 01/12/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211001, Deb Wockenfuss, 01/12/21 FD BC/BOX 1/4 S5/S8 Detail S8 T15N R1W S.M. (Not to Scale) utility EAST 330.07' E 4' Peds ave Eave j P Anchor Chnln irdc Fence N/ SHED W Frame do o 64' Note: This survey was performed / a HouseEave n during the winter with appx. 2' of = Z Drive Gate / 1 CD _ Posts standing snow. Every effort was / Canto CC Peek made to ensure a complete survey. 49 v' Shop d o 0 Deck \ Eave o r \ 4 e9 a o 83, See w �:; ag, � � Detail o sVIC � Z m 4.5'x12' D o 6'x9' Stairs 20'x60' tJ C3 septic® shed❑ Conc. Pad m0 C) W 10'41' WQl • I Shtd W OF q�gS \` CD oN Elec r>7 ®ll o • 9 / _ .- W * :TH Retaining o �? tante ...'..4�. :... Wall Posts s i A hony P. Boneta - byBLM Electric CrJ Post Pit? LS-10393D _ 3 3 Lot 25 p t f t t ESS I ONPS- Septic ���� pp I Pipes rn I hereby certify that 1 have surveyed the following described A property: Lot 25, Sec 8, TI 5N, RI W, S.M., and that no T encroachments exist except as indicated hereon. This As-built �' tv cnw„ Roade 5 1 Polte R strve will only show the easements as described and recorded in /DN Elec Mk Fie Bk 162 Pp 279 ARD, Book 162, Page 279, Anchorage Recording District; c{ KRYSTAL LANE under no circumstances should this data hereon be used for FD RBR the construction or establishing of boundary or fence lines. Se T15N1Riw S.M. i WEST �iin,0' APB Land Surveying o �80 Sec 8,T15N,R1W ASBUILT SURVEY SHEET Y • SCALE IN FEET / 12204 East Prince of Peace Drive Lot 25 Melvin L & Ilene Mcewen Eagle River, Alaska 99577 1" = 60' Anchorage Recording District 20805 Birchwood Loop of GRID: NW1357 Chugiak, Alaska 99567 / 1(907) 227-1361 Surveyed: Dec. 21, 2020 DRAFTED: RWR I CHECKED: MUNICIPALITY OF ANCHORAGE DE ~ITMEN'r OF HEALTH AND HUMAN SER ~-S Environmental Health Division ,. 825 "L" Stre(;f~, Anchorage, Alaska 99502, Telephone 264-4720 ON-SITE SE:WAGE DISPOSAL SYSTEM AND/OR WELl.. INSPECTION REPORT ~m~ DISTANCES SEPTIC ABSORPTION A~ , FRO~~.~_ TANK FELD WELL -- LST LI~E Z: ~ / ~'~¢ / ~ 5-~ /~/~ I ~ ; FOUNDATION TANKS I ; - ~ SEPTIC ~ HOLDING T S~.l ~. ~ - ~ ~ TYPE OF SYSTEM ~ ~TRENCH ~ BED '~ W. DFIAIN E~ OTHER ~'/~'~9tl~ ..... Grave w dth '~ ~ ---- -- Number gl lin .... /~,~ WELLS ] ~ PRIVATE ~ OTHER](Identifv) RE'lARKS: ~- -- -- Date Eaglo River, AK 99571 I ~ ~¢'~ . ceMily tllal 1Pis inspecliou wss performed ~ccordin{I to all Municipal and Slate Duidelines in eilect on Ihis~: _ ~. ~ ~ ~ealth ~parlme n, Ap proval~"~~'~ ' ~¢- Date ~.,¢. '"¢,~. 72-013 (3/85) ( 1"l(3rq ) amd hD. 'l:.l'l aJ,], LAGLE RI[V R ENGIN ING S ICES "~lW~II~] Eagle River, Alaska 99577 ] ~UN(ci~(i ~elephone (907)694.-5195 Mr. Steve Morris J Civil Engineer, On-site Services MunicipalityAnchorage,P'O' Box 196650AK°f99519Anchorage'~ REF: Lot 25, T15N R1W Sec.]8 Dear Mr. Morris: The enclosed applzca~lon zs resubmztted for issuance of a septic upgrade permit for a 4 bedroom home usage on the above referenced lot, in addition 'to an upgrade lpeemit for a 3 bedroom trailer on the same lot. The lot currently has. a seepage pit in 'the western section (to be called section A) that w~s installed with no inspection in 1983. The owner has agreed to ins'tail a new leaohfield and a new soil log has been performed. The area idoes not have a ground water problem and therefore the existing see~page pit will be used as an inline grease trap. The existing pit was installed to a depth of 14' and it is noted that the pit contained 62'! o~ standing water demonstrating the effectiveness of the underlying soil layers as a filter material. The recommended trench design ils specified versus use of a sand filter design in 85 material due Itc lack of water table and underlying soil layer that acts as a filt8r (see well loss). I~a sand filter is a blanket requirement in ali 85 soils~ the bed designs enclosed are submitted as alternatives; Each design requires waiving lot line setback requirements to zero. These lot line setbacks should not be a problem due to large (100'~) road easem, ents in the area. The 2nd septic sy'ste~ will serve a 3 bedroom trailer on the eastern side of the lot (~o 'be ealled section B). We are asking for permit approval for section B ia advance of the 7 day monitor, with the condition that the test h61e water monitor be checked at time of actual installation, 6/30/86. The two trailers located on the original site plan have been removed. Each well, section A and B~ will serw~ only one residence, therefore ~hey are private wells. The attached design is recommended. If there are any questions or if additional information is required please feel free lto contact me at 694-6195. Sincerely, [~f~GI~E RIVER I:NGINb. ER..NG- ' ..... I SERVICES P · 0. BOX RIVER, AhASK~*~ 99577 SPECIFI(:ATIONS FOR ON'SIrE eel IlO, oYo lEM I,~EG¢~L:Lot 25, TLSN, R2N, ,~eo. 8 GENERAL .L. [he NeI1 and sepb~o >lan ape for a single -FamiIy residence use only,, 2. The drat~ing and of site plan shali be a par-t o'P this epeol-t'~oa~ion. 5. AII ma~eriaIs andi~orkmanship sha].l meet ~he Anchorage DepaP~rnenb of Health and State D.E.C.. 4. A~iI sell teste arx~ advisory to tshe des:i,g~ and ape to be verified of medi-P~ed J.n Lhe I:~eld by khe engineer-, 5. (/],1 exoavalsions a~d depths are advzsor-y and are Lo be veril:led or modified in the f:~eld by the oontractor bo meet HO~/, D.E.,O recluir~e-'. menks. 6. It is the r'espone~bJ,].:tky of the owner Be obtain ail i']eoessal'-y per'mits or easements and to leoate any adjacent muIti-family wells. '7. The exoavals&on is}bo be exaotly An bhe area shoMn on tshe s).ke plan, any dev%ation r'equir'es elqg2neer appr'eva}. 8. It is al~ays r-eoo~mended that a surveyor looate the line [)oe:[ [:~_011 and the ].ooab~on ot: any ~aeemerlte. DRAiNFIELD 1~ Fhe drainfieId is 1;o ¢ollo~ the natural land contour t;o mainLain uni'fomm total depth of the bed bottom. 2. The bottom of the!bed shall be level, plus or' minus 1.5". 3. 'rhe totaI depth of the bed exoavation J.s r/et to exoeed i4' at any point (seotion i:} ,}~ J,O'). 4. The semen :Line isjto be oonneeted to khe ex,~.sLing sewer line that leads to tl~e exist:Lng seepag8 pit in suoh a mannen that the k~asbe from kine seepage (>it over"f].o~e to the ].eaohfield (seokion (~). l'F the existing line ie oot usable it; should be r'eplaoed. 5. ~N oIeanout is ~o be plaoed at the junction of old fao hen l:Ll/eS. ~., The bed gr'aveI is~ to be oever'ed with typar- 't'abrio matet-~al. 8. SoiI oF eombJ, nati6r~ of soil and exbr'uded beard insular;ion Lo a depbh of 4' or equivale(/t is to be placed oveP the drain-t~ield. 9., 1he area over~ ~he~bed is to be -finis/ graded t;o prevent pending ot: su r'-~ ace iO. The septzc Lank a~d leachfield mus~ not be closer than 100 Fee~ to any existing private ~ell, 150' to any Claes "0" tael],, or- 200 feet to any oommunity RE(}OMMEN]DED LE(~ONFIEI_})' DIMENSIONS (-~: TO'I'(~L DEPTH= 8' GRf~VEL DEI~THz 6" BED LENGTFI: 42' BED taIDI'Hx I8' B: DEMI'Hz 9' GIR~VEL.,I DEPTH:-' 6" BED LENGTN:: 4V' BED WIDTH:: 12 NOTE: Both sept:Lo sysbems above aEe~ to have a 2' sand t:ilter plac:ed be,}_oN bhe Ieaoh r'oek. This k~ill require exoavation of exisking sand and 9r'aveI, ~ith replaoement using sand~ designaked as "filter sand," -[his is a muK~loJ, pal nequir'emenk and is notJ neoessat-ily Peeommer~ded by designing engirleer, rill8 to laok eT Mater table LOCATIO~N OF WELL (Pleoee complete either I~ lb or lc.) I · . L-+-e'-°'-I J. OISTANCE AN? DIRECTION FROM ROAD1NTERSE~TIONS WELL LOG Feet Belo. w 16. WATER WELL CONTRACTOR'S CERTIFICATION'. : Form O2~WWR (Il/BI) WATER WELl. RECORD STATE OF ALASKA DEPARTMENT OF NATURAL RESOURES Division of Geological ~ Geophysicol Surveys · Drilling Permit No, A,D.L, NO, sO wE] $, OWNER OF WELL; ~,~ ~/~ 5. DATE OF COMPLETION ~. ~Oobl, ,oo, ORatory Oorlvo~ C3o.g ['~.Auger O.detfed [] Bored FI O~her: [] Oome,.c ~ub g?Supp y [] !ndustr¥ [] Irrigation [] Recharge [] Commorloal diam. S~ln. [] Throade~, [~' Welded diam. In. to ft* Depth Stlcku 9. FINISH OF WELL; Type: ' ~'" Dlameler: I0, STATIC WATER LEVEL:. / ,~,~ ' ft. [] Abovo or E] Below land ,urtoce Equipment used'; ft. Oate fl. afler _~!hre. pumping Length Of Drop;Pipe ~C~" COpoclfy ~g.pmm. 15. W.ator Tempera:lure ~ F 0 C December 29, 1978 I~780186 i Robert E. Lee ~ 185 ~ Chugiak, Alaska 99567 Subject. T15N RIW Section 8 Lot 25 A perm~.t ~Lssued by ~hls department for well and/or sewer system has expired. Permits are issued On a calendar year basis, as stated on 'the permit, by a~thority of Municipal ordinance. .If you have dril. le(t~the well, a well log should be sent to this department to document the installation date° If there are any further questions~ please contact this ofz/oce at 264-4720. Sincerely, Les No Buchholz~ Senior Environmental Specialist I~B/ljw enc: copy of permit h'll':f::-:',]: I'"llJh'l I'.,[I...IHli~:IEI~: OF E:IEI])I:.;:OEfl'"I!~; TIlE I:;~:E:I:;¢J:[F:EE:, :5:[;;:~IE OIur THE :50]:1.. IE;:,~ EE:: ~!:::::" "/'-' ~1'-~ ~ :::: .... ';;:::" L .~ E~E ~"-,,il ~C~ "'~" ~-,,.~1 ::~ .... 'I'HE l..[~::[.,l(:~'l'l-I E) :1: I"lEh]~; ]: Efl'q :[ ~; THE 'LENGTH ,:: :[ I",1 F:'EIE"I' ) O1:::' THE TI:;?.IEI"4CH O1:;;: I)F:F:I :[ F,II::; ]: IEI..I:). THE: DIEF'TH OF' I::1 "I'Fi:E:NE:H O1:~: F'];'I'~ :1:~; TI..IIE D:(t?];TI::II'.,E:[~: E:E'I"HIEIEN THE: ~;I. II(',F:'FII;j:E CII::: THE G[;i:OIJh,[[) I:::ff',lD THE E:CFI'TOH OF; 'f'llE:! E:',:,::C:F:I',,,'F:IT]:EII'.~ (IN F'E:ET::,, 'I'I..IIEF;:E ]::~; IqO E;E:'I" P.I]:I)TH F:'OF4'. 'l'hl~E GF;:FI',/EL E:,E:F'TII )::~; 'f'HE H]:N:[~¥11.JH E:,IEF'TH OF' GI:?.Ft',,,'EL. I:]~[ETHI:EF~:N TI.IE: OI..ITF:'f:II~,L, F:']:F:'IE 1:::II'.4D THE E:O'T"t"EH"I OF' THE: E~:]:<:CI:::IVFI? ]: ON (:~:1'-4 F:'IEET::,. F'IEF:I"I:[T I:tF'F'I..:I:C:FIi",IT HI:':I'_"5 THE l:;?.liE:iil;i:::'CH'q',iii; ]: E', ]: l_ :[ T'.? TCI :[ NrS'I-FIL.LFIT :[ CIN ]: N~!i;F'EE:I' :!: ON:iii; OF FIN'¢ HIE[.I...:5 F:ID..:rFIC:IEi'.,IT TO '1"1-1]: ~; P I r I F I FIN[::, TFI1E J'.,ll..ll','llili~E:l:;i: OF' I;;:E?.ii;:I:E:,EI'.,tC:IES TI..IFFF 'THE I.,.lti;L..[.. I,.1:[I...I.. ..................... 'T' D,.It tl::E;, ,,:::: ;;?_" ::,, % ~'..,,1~ ::E~;; F" lEE: it::::: '-~1' EH:::ICI.:::F]Et..L:[I'.,IG OF' I::11'.,1'.~' :5'.?:5'I"EH I,.I]:THOLFI' I:::' ]: NFIL DL.:F'F:IF:THENT I,.I]:L.I... DIE :E;I...IEi',..]'E:C:'T' 'TEl I','l:l:l'.,!:l:l','ll_.ll,'l E:,]J':'~;'IFINE:E; DE:THE[EN FI 14E:L.L I::INI) F1N"r JJ':i!uZI F:IEE:T F'OI:(: F:I I:::'F:]:',,,'FITE: I.,.1[~:[...[....~ OF:I :I.!~iiE~ '1'(:) ;:?.~!u;i!l F:E:IET F:'I:::'.OH F'I F'LJE',I.:[C: I.,.IE:L.L. E:~E:F'Etq[::,:I:NG IJF'ON "f'HE T'¢I:::'E: (:il:::' F'LIE',L.]:C: I.,IEIJ O't"H!iEI:;i: REI]:!I_I:I:Fi:Ii!:HEi:I",IT~i; I'"ff::t"r' FII::'F'[.."¢. :51::'E:C:]:F:[CFIT]:ON':'5 I:'I',,,'F:I]:LI::IBt_.E; 'FIE) ]:N'_::':;UF~'.E l::'[('.CIl::'li::'l:;]: ~ ~ . II . l 1% 'IF- J::::_ ,, ... I~..... :lie If .... I~ ........ E:', EE: ICi::: EEl Ih"ll IEii~ tEE; IF;;~:: -2~: :::]1 ..... Russell Oyster 694-2774 Civil Engineering Soils 19 Foundations Performed for: 0 8' E EIvG/NEERING 8 DEVELOt'MENT' CO. Legal Descrlptlon._~,j~-~, '~,-,~ Depth (feet). 0 B )X 90, Davis St., Eagle River, Alaska 99577 694-2774 or 333-5240 SOIL LOG Mailing Addr~ess: Ebrl Ellis 333-5240 Surveying Land Oevek)pment ,~oil Characteristics 2 3 4 5 6 7 8 9 10 11 12 Ground Water Encountered: yes No ~ If yes, what depth_~_ , Proposed Installation: Seepage Pit Drain Field_~. Comments: ~ ,~ ~:~Jo_-, t~g,;~, k-g- ~ ~ ~ ~ ,~ Perfomed by: 5'% ~ ~ MUNICIPALITY OF ANCHORAGE Development Services Department; Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 051-092-30 1. GENERAL INFORMATION Expiration Date: 12- — / -2 l/ Complete legal description T1 5N R1 W SEC 8 LT 25 Location (site address) 20805 Birchwood Loop Chugiak AK 99567 Current property owner(s) SANTIAGO JONATHAN Day phone Mailing address 20805 Birchwood Loop Chugiak Real estate agent Day phone 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 AK 99567 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well Q Private Septic R Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ Date of Payment Receipt Number Waiver Fee $ Date of Payment Receipt Number COSA # Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm Eklutna Engineering, LLC Address 19162 Mountain Rd Chugiak AK 99567 Engineer's Printed Name Curtis Townsend, PE Phone 907.406.1058 Date Z` w�. .� %S 6. DSD SIGNATURE Xt GIUJCCG System #1 Approved for A bedrooms ?.9 . D ecutsLo % .� �• �STAMP�� System #2 Approved for bedrooms Disapproved ����sIF�P :No � ,'t.. P���v �OY�®m�gO Conditional approval for bedrooms, with the following stipulations: s3 Original Certificate Date: —2 C9' The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet Eklutna Engineering, LLC curtistownsend(@gmail.com October 12, 2021 Subject: T15N R1W SEC 8 LT 25 OSC211105 Narrative The existing 3 bedroom house is served by a private well and septic system. The septic system consists of a 42' x 36" x 72" effective depth trench. MOA issued permit OSP211001 to replace the septic tank draining this house. The scope of work for this permit was to replace the septic tank at the house and backfill the seepage pit upstream of the new septic tank. This work has been accomplished. In addition to this permitted work, the existing tank draining the old mobile home was removed, and the field abandoned in place. There is an additional well located in the southeast corner of the property. This well was found summer 2021 and decommissioned by Anchorage Well and Pump Service in July 2021. A decommissioning log is included. The casing of the 1982 well was straightened. This well was determined to have water. The water line was routed to provide water to the house. Previously conditional COSA OSC211105 was issued. At this time, we request a full COSA be issued for this property. Sincerely, Curtis L. Townsend, P.E. Attachments ..... qs• p�91 Q i ..... all . No. CE ii . Legal Description: T15N R1 W SEC 8 LT 25 If more than 1 septic system on lot: COSA Checklist # 2 of 2 A. WELL DATA F0 Well log is filed with Onsite (or attached) Date drilled 1982 Total depth 160 ft Cased to 160 ft Q Sanitary seal is functioning correctly W Wires are properly protected Casing height (above ground) ' 12 in. Date of flow test for COSA Parcel ID: 051-092-30 house Structure served by this system well only Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by Anchorage Well and Pump Date of Sample 5'2a,2021 Static water level at beginning of test ft. Comments this describes the 1982 well. well casing was straightened and connected to house B. TANK DATA Age of tank(s) years Tank type/material Measured operating fluid level in septic tank ❑ Standpipes/foundation cleanout per record drawing Date of pumping tank removed summer 2021 D. ABSORPTION FIELD DATA Which system tested (date installed) ❑ ALL standpipes present per record drawing Total measured depth from grade ft (rr Measured depth to pipe infrom grad ft (min) ❑ N/A —pressurized field ❑Monitor tubes go to bottom effective. If not, state depth into effective ❑ Code -required so' over over field ❑ System pre aked (Required i acant for greater than 30 days prior to date ofj st) C. LIFT STATION ❑ Required maintenance completed Age of lift station years Lift station material. Comments:. j Adequacy test date Results ❑ Pass For bedrooms Fluid depth prior to test in Water added gal New depth in Elapsed time min Final fluid depth in Absorption rate gpd Any rejuvenation treatment (past 12 months) lons introduced gallons If yes, enter date al ments/Deficiencies: 1986 field was abandoned summer 2021 COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' Community Sewer Manhole/Cleanout > 100' M Yes if No ft ❑✓ Yes if No ft Neighboring Tank > 100' M Yes if No ft Private Sewer/Septic Line > 25' F-/� Yes if No ft Absorption Field on Lot > 100' r-,(-1 Yes if No ft Holding Tank > 100' Yes if No ft Neighboring Absorption Fields > 100' Animal Containment > 50' F/� Yes if No ft ❑✓ Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' M Yes if No ft r/1 Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ❑ Yes if No ft Surface Water > 100' ❑ Ye if No ft Property Line > 5' ❑ Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' ❑ Yes if No ft Private Wells > ❑Yes if No ft Water Main > 10' — ❑ Yes if No ft Com i y Wells > 200' ❑ Yes if No ft Water Service Line > 10' F-1Yesif No ft eptic tank is under driveway comment below From Absorption Field on Lot to: (Please enter di rfic( Building Foundation > 10' ❑ Yes o ft Property Line > 10' ,❑'es if No ft Water Main > 10' ❑ Yes if No ft Water Servi ine > 10' ❑Yes if No ft Su ce Water > 100' ❑ Yes if No ft if less than required) If absorption field is under driveway comment below Wells on Adjacent Lots: Private Wells > 100' ❑ Yes if No ft Community Wells > 200' ❑ Yes if No ft F. ENGINEER'S COMMENTS summer 2021, the abandoned septic tank formally draining the mobile home was removed. The septic bed formally draining the mobile home was abandoned in place. The 1982 well produces water and was connected to the house. G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. 49 T -H �rtts L, TAv�nsenC COSA Checklist yellow sheet `�� ��;• Date / %/I ee* , ������ 'ORO FESSl—t"-���� � Legal Description. T15N R1 W SEC 8 LT 25 If more than 1 septic system on lot: COSA Checklist # 1 of 2 A. WELL DATA N Well log is filed with Onsite (or attached) Date drilled 1985 Total depth 208 ft Cased to 208 ft ❑ Sanitary seal is functioning correctly 0 Wires are properly protected Casing height (above ground) ' 12 in. Date of flow test for COSA '2'2912929 Static water level at beginning of test 56.5 ft. Comments this describes the 1985 well B. TANK DATA Age of tank(s) < 1 years Tank type/material septic 1plasl,c. Measured operating fluid level in septic tank FW� Standpipes/foundation cleanout per record drawing Date of pumping tank replaced July 2021 D. ABSORPTION FIELD DATA Which system tested (date installed) 1986 Al ALL standpipes present per record drawing Total measured depth from grade 10 ft (max) Measured depth to pipe invert from grade 4 ft (min) ❑ NIA — pressurized field 0 Monitor tubes go to bottom of effective. If not, state depth into effective Q Code -required soil cover over field ❑ System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced gallons Comments/Deficiencies: COSA Checklist yellow sheet Parcel ID: 051-092-30 Structure served by this system house Well production at time of test 3.4 gpm Water storage tank volume 0 gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) Arsenic 4.519 ug/L ❑ Arsenic less than MRL (ND) Collected by Curtis Townsend Date of Sample 11512021 C. LIFT STATION ❑ Required maintenance complete Age of lift station y Lift stationmaterial Comment Adequacy test date 12'2912929 Results ❑✓ Pass For 4 bedrooms Fluid depth prior to test 0 in Water added 895 gal New depth 0 in Elapsed time 261 min Final fluid depth 0 in Absorption rate ' 600 gpd Any rejuvenation treatment (past 12 months) no If yes, enter date E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' El Yes Community Sewer Manhole/Cleanout > 100' ✓v7 Yes if No ft M Yes if No Neighboring Tank > 100' M Yes if No ft Private Sewer/Septic Line > 25' F,_/� Yes if No Absorption Field on Lot > 100' E] Yes if No ft Holding Tank > 100' M Yes if No Neighboring Absorption Fields > 100' Yes if No Animal Containment > 50' Yes if No 0 Yes if No ft if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' ❑✓ Yes if No ft 0 Yes if No From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' 0 Yes if No ft Surface Water > 100' ft ft ft ft ft M Yes if No ft Property Line > 5'✓1 El Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' ❑✓ Yes if No ft Private Wells > 100' 0 Yes if No _ Water Main > 10' R! Yes --if No ft Community Wells > 200' 0 Yes if No _ Water Service Line > 10' F✓ Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' El Yes if No ft If absorption field is under driveway comment below Property Line > 10' rj✓ Yes if No ft Wells on Adjacent Lots: Water Main > 10' Yes if No ft Private Wells > 100'. Yes if No Water Service Line > 10' F/ Yes if No ft Community Wells > 200' Yes if No Surface Water > 100' 0 Yes if No ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATION I certify that / have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet ..... . .. ..... Curtis L. Tov enil 2 NO.CE``�A kit PRO FESst t �.� ft ft ft ft Ekiutna Engineering, LLC curtistownsend@Bmail.com March 16, 2021 Subject: T15N R1W SEC 8 LT 25 Request for Conditional COSA The existing 3 bedroom house is served by a private well and septic system. The septic system consists of a 42' x 36" x 72" effective depth trench. MOA has issued permit OSP211001 to replace the septic tank draining this house. The scope of work for this permit is to replace the septic tank at the house and backfill the seepage pit upstream of the new septic tank. in addition to this permitted work, the existing tank draining the old mobile home will be removed, and the field abandoned in place. There is an additional well located in the southeast corner of the property. It is labeled as 'abandoned' on an older survey. The well casing was not located in December 2020 as the ground was frozen. When equipment is on site to replace the septic tank, a further search for this well will be conducted and it will be verified if it has been decommissioned per MOA water code. The condition of the 1982 well is not known. The well casing is bent just above the pitless. The well casing will be straightened and if water is found in this well and the water quality is sufficient, a new pump will be provided and the water line will be routed to provide water to the house. It is proposed that this repair work will be completed during the summer months when weather and ground conditions are more favorable. The work will be complete by June 15, 2021. Money is being held in escrow to complete this work by First National Bank. See accompanying letter. At this time, we request a conditional COSA be issued for the sale of this property. Recent water samples show that nitrates are absent from the 1985 well water on this property. There is no eminent hazard created by granting this conditional approval. Wastewater is not overflowing the field and the 1982 and 1985 well heads are intact. Sincerely, Curtis L. Townsend, P.E. Attachments GENERAL INFORMA'rlON (a) : MUNICIPALITY OF ANCHORAGE DEPARTMENT oF HEALTH AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATI-- OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OS-SITE SEWER AND WATER FACILITY OF ~ 264-4720 I Application Date July 9 ~_~986 Legal Description (include lot, block, subdivision, section, townshm, range) Lot 25 Sec. 8 T15N R1W Location (address or directions) (b) Applicant Name Dennis Sm_J. th _Telephone: Home 69q-'33~3 Business Applicant Address _P.O, Box ??0922 EaC~TLe Rlver. Alaska 99%?'7 (c) Applicant is (check one): Lendingilnstitution []; Owner/builder El; Buyer []; Other [] (explain); (d) Lending Institution _C3_t,y Mo: Address 40_5 W. (e) Real Estate Company and Agent Address (t) Telephone 'tgage ~uite 100 _Telephone _ 26~-237_9 Anchorage, Alaska 99503 Mail the HAA to the following addiess: Pickup by applicant or engineer TYPE OF RESIDENCE Single-FamilylXl Multi-Family [] Oilier Number of Bedrooms 4 3,: WATER SUPPLY Individual Well [] Community [] Plublic [] Note: If community well system, must h ~ve w~ tten confirmation from the State Department of Enwronmental Conservation attesting to the legality and status. SEWAGE DISPOSAL Onsite [] Public [] Community [] Note: If community well system, must ha' attesting to the legality and status. Page 1 ol 2 Holding Tank [] 'e written conlirmation h'om tile State Department of Environmental Conservation 72-025 (11184) 5,.~i ~ENGINEERING FIRMI ROVIDING .,,IS~EC'FIONSi. TESTS~ FILE SEARCH; I;)A'l,, AND INFORMATION :? - As cerbfled by my seal afb×ed hereto and;es of the vahdahon date shown below, I verdy that my mvesbgabon of th~,~ Health Authority Approval shows that the on-sitewater supply and/or wastewater disposal system is sate, functiona~ and ad'equate for the number of bedrooms and type of ~tructure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date df this inspectioq. Name of Firm "' Address ' ~A~- EE~IVER ~N61NEEBNu uci:W'ICES' Telephone P. 0~, BOX 773294; b"g;'l --5'195- DHEP APPROVAL Approved for Approved bedrooms b ~ _ Disapprove~ _ _ Condithd'nal Date Engineer's Seal Terms of Conditional Approval CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon !he representations given in paragraph 5 above by an independent professional engineer registered in the State ol Alaska. Tbe DHEP does tbis es e courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal end state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-025 nl/84) MUNICIPALITY OF ANCHORAGE (NIOAj h,~C¥~AI~.a'H,.~.. AUTHORITY APPROVAL (HAA) ~ .~[~HECKLIST - FEBRUARY 1984 ~O~C~u~ 264-4720 Legal Description . WELL DATA Well Classification Well Log Present (Y/N) _ Total Depth _ ,~o,~-' Cased to Static Water Level _ / ?/¢/,"~ Casing Height Above Ground /~, Electrical Wiring in Conduit (Y/N) _ Separation Distances from Well: To Septic/Holding Tank on Lol DePth of Grouting Sanitary Seal on Casing (Y/N) Depression Around Wellhead ',Y/N) f A. B, C, D.E.C. Approved (Y/N) Date Completed 7- .5- - ,~'5- Yield : On Ac.o~nlng Lots ~/~' / To Nearest Edge of Absorption Fielc (~n Lot ¢7'~z;'/ : On Aolo~mng Lots ~'2¢,¢ ' To Nearest Public Sewer Line /¢,Z~.. To Nearest Public Sewer Cleanout/Manhole /"'//"~ . To Nea. rest Sewer Service L~ne on LOt Water Sample Collected Dy ~-~_r ~;i /"'~.,c-~-1 ~'--,,~ ,,~ee ,'/~!J- . Date Water Sample -I-est Results _ ._~-;~ ?z/.~_ ,~ Comments B. SEPTIC/HOLDING 'TANK DATA Date Installed /2-~ ~' Standpipes (Y/N) _ y -- Depression over Tank (Y/N) Pumping/Maintenance Contract on File (Y/N) Holding Tank High-Water Alarm (Y/N) Separation Distances from SeDtic/Hotding Tank: To Water--Supply We ¢;'~'~ / To Property Line To Water Main/Service Line ¢'/~ ' Course . Size /,~3--/'~?~'1, No. of Corr pmtments '-~ Air~t ght Caps (Y/N) ~" Foundation Cleanout (Y/N) /~'/ Date Last Pure aed ~/7/~¢?G /~/4 . for /¢/.,4 _ Temporary Holding Tank Permit (Y/N) ..,v/,~.¢_ To Building Foendation / ' To Disposa Field '-'~"~-- ' To Stream, Pond, Lake, or Major Drainage Comments Page 1 of 2 72 026(11/84) C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata Date Installed Width of Field Square Feet of Absorption Area Depression over Field (Y/N) Results of Last Adequacy Test Separation Distance from Absorption Field: To Water-Supply Well '~/~/~ To Building Foundation ,-~E, x Lot ~°/ ,¢ To Water Main/Service Line -¢'"~ / To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area Comments Type of System Design Length of Field Z/..2 / Depth of Field /:z / Gravel Bed Thickness ¢' / Standpipes Present (Y/N) Date of Last Adequacy Test To Property Line /,~- / To Existing or Abandoned System on ; On Adjoining Lots ¢.~o / To Cutbank (if present) LIFT STATION/t~/A Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Electrical Codes (Y/N) Dimensions Manhole/Access (Y/N) ~Pump Off" Level at Vent (Y/N) Pumping Cycles during Adequacy Test. Meets MOA Comments ** Check Permitted Bedroom Rating Against HAA Request ** I certify that I have checked, verified, or conformed to ~11 MOA and HAA guidelines in effect on the date of this inspection. Signed ~,-~~ Date Company ~,~-~-~-~-~-~-~'~/~-f~, MOA No. Receipt No. ~ ~/ ~8te of Payment Page 2 of 2 72-026 (11/84) To EAGLE RIVER ENGINEERING SERVICES INC. P. O. Box 773294 EAGLE RIVER, ALASKA 99577 Phone694-5195 Steve Morris MOA-DHHS It was determined that t]~e septic tank for lot gallon tank. The 800 gallon pump was a result LETTER Date 7/10/86 Subject Lot 25 , Sec. 8 T15N, R1W 25, system A is a 1250 of the tank being pumped two weeks previous, and ~ot being full at time of secound pmnping. Sanitary pumping serviceihas provided a reciept for 1250 gallons. Health ^uthor±gy approval is being applied for Based on approval of this upgraded septic system. [] Please reply ..~ No reply ne!essary Lo.u_Bt~e~a~ February 21~ 1985 Mr. Dennis Smith Chug'iak, Alaska ' b~ar ~.~'~'-"Smith: In reference to our phone conversation of February this letter is to ~onfirm '-' -~ ouz company in fac'b~ install a sewer system at your residence on Sou%h Birc~wood Loop in Octc, ber of 1983. Th,% system utilized a 125Q-gallon! two-~compartment septic tank and a 300-gallon seepage pit~ Th.e suSsurface soils w~e a well-gradedl.sand and grave], of an 85 square feet. - ,-: ¢~ ground ~ater was. encountered pet':bedroom ~u~n~? and no ~t is my opinion that the system is more than adequate to service a four-bedroom homer and because ~t is a recent installation~ no upgrade would' De necessary at t~J~s' time: If our company cani~ be of any not/~esitate to ~aill~ further ass.istancer please do Site Preperatlon I l Concreto Foundations I Trucking / Grading LIcenaed Contractor / Top Soil / Sand & Gravel MUNICIPALITY OF ANCHOR/AGE DE! TMENT OF HEALTH AND I-.IUI~IAN SER~ :S I Environmental Health Division 825 "L' Street, Anchorage, Alaska 99502, Telephone 264-4720 ON-srr'E SEWAGE DISPOSAL SYSTEM AND/OR WELl. INSPECTION REPORT Address LEGAL DESCRIPTION TANKS ,~ SEPTIC [] HOLDING Marshal / No: Compadmenls TYPE OF SYSTEM [] TRENCH J~l BED ~ W, DRAIN E~ OTHER F~r_ Fei added above ongmal grad; /--- ~ //.~..f 2D.._J ' Z~-~~ sQ Ff [~' PRIVATE Gravel depU~ benealh pipe ) -2 WI=bIS L~ OTHERi ildentit¥~ 1sial Depth 7' Cased to ~T REMARKS: FT Mueicipal end SBte guidelines in ellect on Ihis da Health Deparlment Approvah 72-013 (3/85) DISTANCES '~]---T[ SEPTIC ADSORPTION FROM ~ TANK FIELD WELL WELL }~- / '~luo / LOT LINE ~- / '2 6-' ,~0 / FOUNDATION /// Scale: Inspections Pedormed by: Eagle River EnCneering Services -P71~, uox ?/329T bate: Eagle Rive.r; ^K 99577 __ certify Ihal Ihis inspeclion was pedermed accordinll to ell _ rE N ¢iN'E~ii'~,'¢EAL'' DEF::'AI::':IT'IENT ]"Jllii:Al..'ltl AND li!:NV:I:RDNMI!]xI'I'AI d)ILC I iON E12'.5 I... ,~ TI:~EEi:'I~, F~IfM'IUF~.II'.'IE. AK 995 2 6 4-'4 7~:~ Il.) ...... ~ ). I,()l,I. ,, NA :LSN RANL.)I:: 1W with all MOA (;::(::~(:l~i:~!~i Nil I NOt BE AI:::'PRE)VI:[O N:t: I'H[I/FI AN ELI~:C'IRICAL. ]:NSF'ECl"ION REPOR'I"; AN[) (3) THE ..... ~ DA Il=.: ................. ii[ LAGLE RIVER ENGINE]ERING SER ICES ,/k. ; Lo,, ~l~~ ~ Eagle Rivm', Alaska 99577 all[ li Telephone (907) 694..5195 June 19, 1986 Mr. S'5eve Morris ~ Civil Engineer, On-site S~rvices Municipality of Anchorage[ P.O. Box 196650 Anchorage, AK 99519 REF: Lot 25, T15N R1W See.8 Dear Mr. Morris: The enclosed applie~ticn is resubmitted for issuance of a septic upgrade permit for a 4 be~,dr¢om home usage on the above referenced lot, in addition to an upgradel permit for a 3 bedroom trailer on the same lot · The lol; currently has a seepage pit in the western secti, on {to be called section A) that was installed with no inspection in 1983. The owner has agreed to inst~ll a new leachfield and a ne~ soil log has been performed. The are~ does not have a ground water problem and therefore the existing seepage pit will be used as an inline grease trap. The existing pit ~as installed to a depth of 14' and it is noted that the pit contained 62" of standing water demonstrating the effectiveness ef the und&rlying soil layers as a filter material. ThD_ 'trench design is specifi~ed~_yersus use of,a_sand filter d~esign in 85 material du~ .ge lsck of_ ~ater !;ab._ .l_e and~und~r_l~ri~L~ soil layer that_~a~t_~s The 2nd septic systdm will serve a 3 bedroom trailer on the eastern side of the lot (~to be called section B). We are asking for B permit approval for section in advance of the 7 day monitor, with the condition 'that the test hole water monitor be c. hecked at time of actual installation, 6/30/86. The two trailers located on the original site plan have been removed. .Each well, section A and B, will serve only one residence, therefore ithey are private wells. The attached design is recommended. ] If there are any' questions or if additional information is required please feel fre~ to contact me at 694--5195. Sincerely, Leu Butera, P.E. LkGAL; Lot ~5~ EAGL, g ][VIER ENGINEERING SERVICES P.O. BOX 77~294 EAGLE R~VER, AL&~KA 99577 J 694-5195 SPEO.[FIOAT~ONS FOR ON-SI'rE SEPTIC 'l'lSN, R2W, Sect 8 GENERAL 1,, The well sepLio plan]ace for a single family residence use only. 2. The drawing and or slte plan shall bo a part of this speoifioahion. 5, All maherials and ~or'kmansh~p sh¢,ll meet the t-equiremenks of the Anoho'~age Depamtrpent o~ Health and State 4. All soil beslss are aCvisory ~o the design and. are to be veF:Lf.i, ed or modifiedjin I;he f~old by l;he engineer'. 5. All excavations atnd depths are advisory and are bo be verlfied of modsfied in Line 't:iel~ by the oonhr'aoLor Lo meek MOA, D.E.O roquir'e-,- 6. It is tine responsibility off the owner ko obtain a],l per'mits or easementsland to locate any ad/laoent multi-family we,}].s. 7. ]'he excavation is to'be exactly in the area sho~n on the sike plan ]:t is al. ways '*eoomme¢~ded ghat a SLIUVgyOP looa~e the nearest lois line position and Line looag:i, on of any easement;s. DRAZNFIELD 1. Fhe draJnfield is tsol fo].low th(.~ r'~atural land contour Lo mainkain uniform ~oLa] depth 6f ~he Ecenoh bo~om. 2 The bottom of the hr'0nch shall be lew~l, plus OF minus 5 The total dephh o'F the tr'enoh excavation is not 'Lo exceed 14' at any po-Lnl: (sectS, on B- 4 The se~eP ~ne :ts ~o be connect;ed Bo ~l]e exisLS, ng se~er ]ire bhaL leads to ~he exisL}n~ seepage p&t in such a manner ~ha~ ~he epee l;.he seepage p}t;,J overflows l;o ~he leaehfil~l.d (section A),. Zf ex,sting line ~s not;l, usable &B should be replaced, 5: A oleanouh ~s I;o be p}aoed a~ th(~ 9unction of o}d ~o ne~ ].:Jr]es. 7. The Lrer/oh gravel isl to be covered ~h bypar fabr-;i.o raa~er~.a}. 8. Soil or combination OP soi~ and extruded boaPd tnsuLatJ, on to a dephh of 4' or equ~valen~ ~.s to be placed over the dr'ainfie}d. 9, The ar'ea over ~he be~ ~s bo be f~nish graded ho preven~ ponding of surface uaber cunpff. lO. The septic tank and ~eachf~eLd rnus~ not be c}osec ~han lO0 feet; ho any existing pr~v~x~8 we~, 250' t;o any CLass "0" ~e.L~, of 200 Lo any oommun&t.y RECCOMENDED I E'ACHFIEI,,]) ])]]NENSIONS A: TOTAl- DEF'X'I'~z ],4' Gr~AVEL DEPTH:: 10' TRENCH LENGFH: 57.5' B: TOTAL DIEPTH:: 10' GRAVE~ DEPTH: 4.5' TRENCH LEIqGTH:: 29' NOrE: If the existJ, ng seX) less than 4' be]ow the b6 decreased and the bren bio tank outlet is aL a ro]lative elevation of ~noh location the hotal grav~;1 depth may Iqave to bt] length inoreas?,ed to oornpel']eate on septic PERFORMED FOR: LEGAL DESCRIPTION:_ 2 4z 5- 7 8 9 10 11 12 13 14 15 16 17 18 19 2O MUNICIPALITY OF ANCHORAGE DEPARTMENT O~ HEALTH AND ENVIRONMENTAL PROTECTION 82§ L, S~reet Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST SOILS LOG [] PERCOLATION TEST SLOPE SITE PLAN COMMENTS WAS GROUND WATER S ~NCOUNTERE[3? /Y~JO L O iF YES, ATWHAT ~ DEPTH? Gross Net Depth to Net Reading D~te Time Time Water Drop ..j~3C,~-A-T-t~N RATE ~-~-- ~/'-'/~ ~ (minutes/inch) ~I'EST RUN BETWEEN FT AND FT PERFORMED BY:_ 72-o08 (6/79) P. U. U0X 713294 Eagle Elve~ AK g§§77 694-51S§ CERTIFIED BY: ~'~ PERFORMED FOR:. LEGAL DESCRIPTION: 1 2 4 $ 7 ~3 ~4 17 ~.- 20- COMMENTS ~-re -,,04 PERFORMED BY: 72-008 (6/79) MUNICIPALITY OF ANCHORAGE DEPARTMENT OF!HEALTH AND ENVIRONMENTAL PROTI:CTIC)N 825 L, St?eet, Anchorage, Alaska 99501 264-4720 SOIL;S LOG -" PERCOLATION ]'EST SLOPE SOILS LOG [] PERCOLATION TEST PLAN 7:,22. :- /z// P. O. Box 773294 Eagle Rlyor, AK 99577 694-5195 WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT 'Tr~e~ DEPTH? ] C) ,7"-~ ! ~_'~ ~ ',~1' '~/~. (minutes/inch) ,P ~i~ ,'qD~'/VTd~4N RATE ' ]TEST RUN BETWEEN .... FT AND , FT. .' CERTIFIED BY: /:~~ DATE:~/~/~'' hereby certify that LOT ~-~'- ~-~t~¢Cl:--'~~/a~ ~' chorage Recordln9 ]]lstrlct~ hlaskal~ has bee~ survexed by me and at no encroachmenl~ exist except als shown hereon. It is the sponsibtltty of the o~ner to. determine the'existence of any sements~ covenants, or restrictioffs uhtch do not appear on the corded subcli~ision plat. Listed dlslances prevail and scaling ould not be attempted to determine,.unshown dimensions. Th'is ~vey is not adequate for, nor should it be used for tablishing boundary or fence lines. JOB NTTO'/'~--/:]O Gn|O /,4a//gg"J FIELD Division of Geological ~ Geophysical Surveys .t ,%. ,%. Comde4eviaAk CcDsA- MUNICIPALITY OF ANCHORAGE �^ �� Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Parcel I.D. 051-092-30 Certificate of On -Site Systems Approval Expiration Date: l9 —&-2-' Complete legal description T1 5N R1 W SEC 8 LT 25 Location (site address) 20805 Birchwood Loop Chugiak AK 99567 Current property owner(s) MCEWEN MELVIN & ILENE Day phone Mailing address Real estate agent 20805 Birchwood Loop Chugiak Aaron Asbury 2. TYPE OF DWELLING: Fxj Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 AK 99567 Day phone 907.231.1159 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well El Private Septic F Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 13 4 () r Date of Payment /�/ ' Z Receipt Number Cq q y D COSA # 05G2 I f 105 Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm Eklutna Engineering, LLC Phone 907.406.1058 Address 19162 Mountain Rd Chugiak AK 99567 / Engineer's Printed Name Curtis Townsend, PE Date ( 2 �.� OF A/ ,all�� 5'c, ��a • 6. DSD SIGNATURE �•••��. Y o CurSs L Tovm nd System #1 Approved for bedrooms ��•. Date /0I�2o2{.`a-'` No.CE11 •.<c System #2 Approved for bedroomsPROFESSIO`�A�~ Disapproved _�� Conditional approval for bedrooms, with the following stipulations: -.+ av- k, , V d s P 241 n0 ( 1-1 11 By: Original Certificate Date �3- OF- 2 l The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet Legal Description: T15N R1 W SEC 8 LT 25 If more than 1 septic system on lot: COSA Checklist # of A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled 1985 Total depth 208 ft Cased to 208 ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) ' 12 in. Date of flow test for COSA 12/29!2020 Parcel ID: 051-092-30 Structure served by this system Well production at time of test 3.4 gpm Water storage tank volume 0 gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) Arsenic 4.519 ug/L ❑ Arsenic less than MRL (ND) Collected by Curtis Townsend Date of Sample 1/512021 Static water level at beginning of test 56.5 ft. Comments this describes the 1985 well, currently connected to house B. TANK DATA Age of tank(s) years Tank type/material Steel Measured operating fluid level in septic tank ❑ Standpipes/foundation cleanout per record drawing Date of pumping tank to be replaced June 2021 D. ABSORPTION FIELD DATA Which system tested (date installed) ❑ ALL standpipes present per record drawing Total measured depth from grade 10 ft (max) Measured depth to pipe invert from grade 4 ft (min) ❑ N/A —pressurized field ❑ Monitor tubes go to bottom of effective. If not, state depth into effective ❑ Code -required soil cover over field ❑ System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced gallons Comments/Deficiencies: COSA Checklist yellow sheet C. LIFT STATION ❑ Required maintenance comp) Age of lift station y Lift station material Comment Adequacy test date 12/29/2020 Results ❑✓ Pass For 4 bedrooms Fluid depth prior to test 0 in Water added 895 gal New depth 0 in Elapsed time 261 min Final fluid depth 0 in Absorption rate ' 600 gpd Any rejuvenation treatment (past 12 months) no If yes, enter date E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' F71 Yes if No Community Sewer Manhole/Cleanout > 100' ❑✓ Yes if No ft / Yes if No ft Neighboring Tank > 100' F/71 Yes if No ft Private Sewer/Septic Line > 25' Fv-� Yes if No ft Absorption Field on Lot > 100' 0✓ Yes if No ft Holding Tank > 100' M Yes if No ft Neighboring Absorption Fields > 100' Yes if No Animal Containment > 50' 171 Yes if No ft 0✓ Yes if No ft if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' MYes if No ft � Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' 121 Yes if No ft Surface Water > 100' ® Yes if No ft Property Line > 5' F71 Yes if No ft Wells on Adjacent Lots: Absorption Field? 5' F/� Yes if No ft Private Wells? 100' 0✓ Yes if No ft Water Main > 10' 0✓ Yes if No ft Community Wells > 200' ❑✓ Yes if No ft Water Service Line > 10' Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' Yes if No ft If absorption field is under driveway comment below Property Line > 10' Q Yes if No ft Wells on Adjacent Lots: Water Main > 10' Yes if No ft Private Wells > 100' Q Yes if No ft Water Service Line > 10' Q Yes if No ft Community Wells > 200' Q Yes if No ft Surface Water > 100' 0 Yes if No ft F. ENGINEER'S COMMENTS MOA has issued OSP211001, this work will be completed summer 2021. We seek a conditional COSA at this time. New tank will meet separation distances. G. ENGINEER'S CERTIFICATION I certify that l have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. ENGINEER'S COSA Checklist yellow sheet Legal Description: TI 5N R1 W SEC 8 LT 25 If more than 1 septic system on lot: COSA Checklist # of A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled 1982 Total depth 160 ft Cased to 160 ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) ' 12 in. Date of flow test for COSA Parcel ID: 051-092-30 Structure served by this system Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? ❑ Yes ❑ Nc ❑ Coliform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by Date of Sample Static water level at beginning of test ft. Comments this describes the 1982 well. water is not currently able to be drawn. will be tested later. B. TANK DATA Age of tank(s) 35 years Tank type/material septic Measured operating fluid level in septic tank ❑ Standpipes/foundation cleanout per record drawing Date of pumping tank to be removed summer 2021 D. ABSORPTION FIELD DATA Which system tested (date installed) ❑ ALL standpipes present per record drawing Total measured depth from grade ft (max) Measured depth to pipe invert from grade ft (min) ❑ N/A — pressurized field ❑ Monitor tubes go to bottom of effective. If not, state depth into effective ❑ Code -required soil cover over field ❑ System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced gallons Comments/Deficiencies: 1986 field to be abandoned summer 2021 COSA Checklist yellow sheet C. LIFT STATION ❑ Required maintenance com Age of lift station ye -as Lift station materia Comment Adequacy test date Results ❑ Pass For bedrooms Fluid depth prior to test in Water added gal New depth in Elapsed time min Final fluid depth in Absorption rate gpd Any rejuvenation treatment (past 12 months) If yes, enter date E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' if No ft ❑ Yes Community Sewer Manhole/Cleanout > 100' ❑ Yes ❑, Yes if No ft ED Yes if No ft Neighboring Tank > 100' ITV Yes if No ft Private Sewer/Septic Line > 25' El Yes if No ft Absorption Field on Lot > 100' Q Yes if No ft Holding Tank > 100' Yes if No ft Neighboring Absorption Fields > 100' Animal Containment? 50' Yes if No ft ITV Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' MV Yes if No ft � Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ❑ Yes if No ft Surface Water> 100' ❑YeifNo ft Property Line > 5' ❑ Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' ❑ Yes if No ft Private Wells > ❑ Yes' if No ft Water Main > 10' ❑ Yes if No ft Com ity Wells > 200' ❑ Yes if No ft Water Service Line > 10' ❑ Yes if No ft -�l eptic tank is under driveway comment below From Absorption Field on Lot to: (Please enter di afi"( Building Foundation > 10' ❑ Yes o ft Property Line > 10' Water Main > 10' / W:c-e- Serv' ine > 10' Su Water > 100' ,LJ -Yes if No ft ❑ Yes if No ft ❑ Yes if No ft ❑ Yes if No ft if less than required) If absorption field is under driveway comment below Wells on Adjacent Lots: Private Wells > 100' ❑ Yes if No ft Community Wells > 200' ❑ Yes if No ft F. ENGINEER'S COMMENTS summer 2021, the abandoned septic tank will be removed. The septic bed will be abandoned in place. If this well produces water, it will be connected to the house. We seek a conditional COSA. G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet �-Ikk � ' Curtis ' ' qvm' nd' •� • Date ••G� Z..ctr• C E 1 .004 ;ate s rESS, ENGINEER'S Eklutna Engineering, LLC curtistownsend@gmail.com March 16, 2021 Subject: T15N R1W SEC 8 LT 25 Request for Conditional COSA The existing 3 bedroom house is served by a private well and septic system. The septic system consists of a 42' x 36" x 72" effective depth trench. MOA has issued permit OSP211001 to replace the septic tank draining this house. The scope of work for this permit is to replace the septic tank at the house and backfill the seepage pit upstream of the new septic tank. In addition to this permitted work, the existing tank draining the old mobile home will be removed, and the field abandoned in place. There is an additional well located in the southeast corner of the property. It is labeled as 'abandoned' on an older survey. The well casing was not located in December 2020 as the ground was frozen. When equipment is on site to replace the septic tank, a further search for this well will be conducted and it will be verified if it has been decommissioned per MOA water code. The condition of the 1982 well is not known. The well casing is bent just above the pitless. The well casing will be straightened and if water is found in this well and the water quality is sufficient, a new pump will be provided and the water line will be routed to provide water to the house. It is proposed that this repair work will be completed during the summer months when weather and ground conditions are more favorable. The work will be complete by June 15, 2021. Money is being held in escrow to complete this work by First National Bank. See accompanying letter. At this time, we request a conditional COSA be issued for the sale of this property. Recent water samples show that nitrates are absent from the 1985 well water on this property. There is no eminent hazard created by granting this conditional approval. Wastewater is not overflowing the field and the 1982 and 1985 well heads are intact. Sincerely, Curtis L. Townsend, P.E. Attachments March 16, 2021 RE: Escrow Holdback: Buyer(s): Jonathan James Santiago Property Address: 20805 S Birchwood Loop Road, Chugiak, AK 99567 This letter concerns the above listed property. Funds will be collected and placed into an Escrow Holdback Account to ensure the completion of the items listed below. The deadline for completion is 07/31/2021. Please see the attached Escrow Hold Back request for Loan Number 0102071973. Items to be completed/repaired: • remove/replace existing septic tank with a 1250 gallon tank at the house, provide double cleanouts • backfill the seepage pit at the house; At the old MH site, remove the septic tank & backfill; Decommission the '82 well OR connect it to the house, well casing needs to be straightened out • For the SE well, either decommission or verify that it is decommissioned • Completed/ApprovedCOSA; First National Bank Alaska will release the escrowed funds upon receipt of a final unconditional Certificate of On - Site Systems Approval issued by the On -Site Water & Wastewater Section. Should you have any questions, please do not hesitate to contact me. Sincerely, Lita Beck VP/Underwriting Manager 907-777-5678 LBeck@fnbalaska.com First National Bank Alaska, NMLS #640297 101 W 36th Avenue, Ste 216 • P.O. Box 100720 • Anchorage, AK 99510-0720 Escrow Holdback Request Loan Number: 0102071973 Subject Property: 20805 S Birchwood Loop Road Borrower Last Name: Santiago Chugiak, AK 99567 Escrow setup: Escrow Required Completion Date: 07/31/2021 Escrowed Funds Provided By: Borrower: Seller: X Request to hold funds for the following repairs: ® remove/replace existing septic tank with a 1250 gallon tank at the house, provide double cleanouts ® backfill the seepage pit at the house; At the old MH site, remove the septic tank & backfill; Decommission the '82 well OR connect it to the house, well casing needs to be straigtened out ® For the SE well, either decommission or verify that it is decommissioned ® Completed/Approved COSA Escrow calculation: Bid Completed By: Contractor Total Bid Amount: (Using the larger of the two bids provided, multiply the total estimated bid by 1.5 to calculate total bid amount) $ 125,698.00 Appraisal: Re -inspection Fee: $ 1,490.00 Total Funds Escrowed: (Total Funds Escrowed will be held at closing) $ 127,188.00 Approval: Underwriter Approval: Date:// Senior Management Approval (If Applicable): ** Attach all bids / email approvals / additional documentation as applicable ** D `¢SMP sE� Bill To Anchorage Well & Pump Service, Inc. 330 East 76th Avenue Anchorage, Alaska 99518 (907) 243-0740 John Santiago 20805 South Birchwood Loop Chugiak, AK 99567 Quote Invoice #: 20206045 Ship To: John Santiago 20805 South Birchwood Loop Chugiak, AK 99567 SALESPERSON YOUR NO. SHIP VIA COL I PPD SHIP DATE TERMS DATE PG. TYLER S RIDGWAY QUOTE Net 10 1/6/2021 1 TY. I ITEM NO. DESCRIPTION PRICE DISC % EXTENDED TX. PRICE 1 ! Scope of Work: PART 1 SITE UPGRADE GAIN ACCESS TO 'BENT WELL" PITLESS ADAPTER TO PERFORM PUMPING HEAD TEST/ FLOW TEST ON WELL. DETERMINE IF WELL IS USEABLE, IF NOT -ABANDON WELL CASING APPROX 150— FT 1 INSTALL GAIN ACCESS TO PITLESS ADAPTER, $1,500.00 $1,500.00 PULLING WELL PUMP, INSTALLATION OF TEMPORARY WELL TEST EQUIPMENT, PERFORMING PUMPING HEAD TEST, FLOW TEST, SAMPLES 1 SAMPLES COLIFORM /ARSENIC / NITRATE $160.00 $160.00 1 EQUIPMENT EQUIPMENT DAILY CHARGES: $175.00 $175.00 GENERATOR RENTAL Subtotal $1,835.00 1 OPTION: IF PUMPING HEAD TEST, FLOW TEST, AND SAMPLES PROCURE SATISFACTORY RESULTS - INSTALL NEW.EQUIPMENT INSIDE OF WELL (CONSTANT PRESSURE SYSTEM), AND UPGRADE WELL CASING (24" ABOVE GRADE) WITH NEW SANITARY WELL SEAUCONDUIT 1 NOTE: PRICING BASED OFF OF WELL DEPTH ESTIMATION BEING AROUND 150-200 FT THIS EXCLUDES ANY UNDERGROUND WORK TO PITLESS ADAPTER OR UNDERGROUND LINE - TO BE COVERED BY THE EXCAVATOR SALE AMT.FREIGHT We appreciate your business. SALES TAX TOTAL AMT. PAID TODAY BALANCE DUE 4aCH0RgCm D PS Anchorage Well & Pump Service, Inc. 330 East 76th Avenue Anchorage, Alaska 99518 (907) 243-0740 John Santiago 20805 South Birchwood Loop Chugiak, AK 99567 Quote Invoice #: 20206045 Ship To: John Santiago 20805 South Birchwood Loop Chugiak, AK 99567 SALESPERSON YOUR NO. SHIP VIA COL PPD SHIP DATE TERMS DATE PG. TYLER S RIDGWAY QUOTE Net 10 1/6/2021 2 :)TY. ITEM NO. DESCRIPTION PRICE DISC % EXTENDED TX. PRICE 1 I INSTALL INSTALLATION CHARGES $1,500.00 $1,500.00 1 I GRUNDFOS GRUNDFOS PUMP: 10WQE07-240 $1,800.00 $1,800.00 1 GRUNDFOS CU -301 CONSTANT PRESSURE $900.00 $900.00 CONTROLLER + TRANSDUCER 1 j MW01 Well Seal WTCC-6 Midwest Code $70.00 $70.00 200 Pipe-PVC1.25" Pipe -PVC -1.25" $3.90 $780.00 8 Pipe -PVC -Coupling PVC Drop Pipe Coupling $5.00 $40.00 1 Flomatic 1.25" ECK Bronze Check Valve1.25" LeadFree $71.00 $71.00 215 E005 12/3 Flat Jacketed Cable/Grd $2.00 $430.00 1 E000 Submersible Splice Kit $15.00 $15.00 1 GBR1.25 X 1 GALV. BELL REDUCER 1.25' X 1" $19.00 $19.00 1 1 RBN 1 X 2 NIPPLE $10.00 $10.00 6 WELL CASING 6" ASTM SCHEDULE 40 $28.00 $168.00 1 BAKER 100BT-1" PITLESS ADAPTER 100BT-1" $138.00 $138.00 1 FLARE 1 X 1 MIP 1 X 1 FLARE MIP $44.00 $44.00 600 E016 12/3 Underground Cable/Jky/Grd $1.80 $1,080.00 1 EQUIPMENT EQUIPMENT DAILY CHARGES: WELDER $175.00 $175.00 RENTAL 1 EQUIPMENT EQUIPMENT DAILY CHARGES: $175.00 $175.00 GENERATOR RENTAL Subtotal $7,415.00 1 OPTION: IF WELL DOES NOT PRODUCE SATISFACTORY RESULTS - ABANDON WELL PER MOA CODE 1 INSTALL INSTALLATION CHARGES: CUT WELL $900.00 $900.00 CASING OFF BELOW GRADE, FILL WITH 3/8 HOLE PLUG BENTONITE, WELD ON 6" DOME CAP, SUBMIT ADBANDONMENT FORM TO MOA 1 Weld Cap Domed Weld On Cap 6" $86.00 $86.00 We appreciate your business. SALE AMT.FREIGHT SALES TAX TOTAL AMT, PAID TODAY BALANCE DUE c�08 1 % P Bill To: Anchorage Well & Pump Service, Inc. 330 East 76th Avenue Anchorage, Alaska 99518 (907) 243-0740 John Santiago 20805 South Birchwood Loop Chugiak, AK 99567 Quote Invoice #: 20206045 Ship To: John Santiago 20805 South Birchwood Loop Chugiak, AK 99567 SALESPERSON YOUR NO. SHIP VIA COL PPD SHIP DATE TERMS DATE PG. TYLER S RIDGWAY QUOTE Net 10 1/6/2021 3 TY. ITEM NO. DESCRIPTION PRICE DISC % EXTENDED TX. PRICE 55 BENTONITE 3/8 Hole Plug $43.50 $2,392.50 1 EQUIPMENT EQUIPMENT DAILY CHARGES: $175.00 $175.00 GENERATOR RENTAL Subtotal $3,553.50 1 Scope of Work: PROPER ABANDONMENT OF WELL NOT CURRENTLY IN USE (THIRD WELL ON SITE) 1 INSTALL INSTALLATION CHARGES: CUT WELL $900.00 $900.00 CASING OFF BELOW GRADE, FILL WITH 3/8 HOLE PLUG BENTONITE, WELD ON 6" DOME CAP, SUBMIT ADBANDONMENT FORM TO MOA 1 Weld Cap Domed Weld On Cap 6" $86.00 $86.00 55 BENTONITE 3/8 Hole Plug $43.50 $2,392.50 1 EQUIPMENT EQUIPMENT DAILY CHARGES: $175.00 $175.00 GENERATOR RENTAL Subtotal $3,553.50 SALE AMT. $16,357.00FREIGHT We appreciate your business. $0.00 SALES TAX $0.00 TOTAL AMT. $16,357.00 PAID TODAY $0.00 BALANCE DUE $16,357.00 �cNOR D Anchorage Well & Pump Service, Inc. v, 330 East 76th Avenue Quote Anchorage, Alaska 99518 (907) 243-0740 Invoice #: 20211031 John Santiago 20805 South Birchwood Loop Chugiak, AK 99567 Ship To: John Santiago 20805 South Birchwood Loop Chugiak, AK 99567 SALESPERSON YOUR NO. SHIP VIA COL PPD SHIP DATE TERMS ( DATE PG. I TYLER S RIDGWAY QUOTE 2 Net 10 1/7/2021 1 TY. ! ITEM NO. DESCRIPTION PRICEDISC % EXTENDED TX. I PRICE 1 Scope of Work: PART 2 SITE UPGRADE FURNISH EQUIPMENT INSIDE OF BUILDING PRESSURE TANK, PRESSURE SWITCH, CONTROLS, PLUMBING OF TANK/FITTINGS, CONTROLLER ETC 1 INSTALL INSTALLATION CHARGES $1,600.00 $1,600.00 1 WX-302/CM17002 86G-WELL-X-TROLTANK $1,046.00 $1,046.00 2 Flomatic 1" E CK Flowmatic 1" Check Valve-LeadFree 100E $52.00 $104.00 2 CMA1 COPPER MALE ADAPTER/SWT/1.0" $10.00 $20.00 6 AYM: DEU 1" Dielectric Union 1" FIP X SWT $12.00 $72.00 4 C901 COPPER 90/SWT/1.0" $10.00 $40.00 6 AYM:RBNipple 1" X Close RBNipple 1" X Close $6.00 $36.00 1 TANK T KIT -1" T -SWITCH -GAUGE -CK -VALVE -FTG $220.00 $220.00 1 CT1 COPPER TEE/SWT/1.0" $21.00 $21.00 1 MW02 Pressure SwitchFsg-2 40/60 SqD $40.00 $40.00 15 CP1 COPPER PIPE -TYPE M-1.0" $8.00 $120.00 2 TBV1.0 THREADED BALL VALVE 1.0" $36.00 $72.00 1 FILTER BIG BLUE TRIPLE FILTER HOUSING $600.00 $600.00 1 FILTER CARTRIDGE SEDIMENT, IRON, CARBON FILTER $260.00 $260.00 CARTRIDGE 1 PARTS: MISC FITTINGS/HARDWARE $200.00 $200.00 Subtotal $4,451.00 1 OPTION: OVERHAUL IN -USE WELL EQUIPMENT 1 INSTALL INSTALLATION CHARGES $800.00 $800.00 1 GRUNDFOS GRUNDFOS PUMP: 10SQE07-240 $1,800.00 $1,800.00 1 f GRUNDFOS I CU -301 CONSTANT PRESSURE $900.00 $900.00 CONTROLLER + TRANDSUCER 1 MW01 Well Seal WTCC-6 Midwest Code $70.00 $70.00 200 Pipe-PVC1.25" Pipe -PVC -1.25" $3.90 $780.00 We appreciate your business. SALE AMT. FREIGHT SALES TAX TOTAL AMT. PAID TODAY BALANCE DUE Bill To: Anchorage Well & Pump Service, Inc. 330 East 76th Avenue Anchorage, Alaska 99518 (907) 243-0740 John Santiago 20805 South Birchwood Loop Chugiak, AK 99567 Quote , Invoice #: 20211031 Ship To: John Santiago 20805 South Birchwood Loop Chugiak, AK 99567 SALESPERSON YOUR NO. SHIP VIA COL PPD SHIP DATE TERMS DATE PG. TYLER S RIDGWAY i QUOTE 2 Net 10 1/7/2021 2 TY. I ITEM NO. DESCRIPTION PRICEDISC % EXTENDED TX. PRICE 8 Pipe -PVC -Coupling PVC Drop Pipe Coupling $5.00 $40.00 1 Flomatic 1.25" ECK Bronze Check Valve1.25" LeadFree $71.00 $71.00 215 E005 12/3 Flat Jacketed Cable/Grd $2.00 $430.00 1 E000 Submersible Splice Kit $15.00 $15.00 1 GBR1.25 X 1 GALV. BELL REDUCER 1.25" X 1" $19.00 $19.00 1 RBN 1 X 2 NIPPLE $10.00 $10.00 1 PVC -Tape Premium All Weather -Black $6.00 $6.00 I i i i Subtotal i i I $4,941.00 We appreciate your business. SALE AMT. $9,392.00FREIGHT $0.00 SALES TAX $0.00 TOTAL AMT. $9,392.00 PAID TODAY $0.00 BALANCE DUE $9,392.00 JR's Septic Pumping and Excavation PO Box 773415 Eagle River, AK 99577-3415 Name / Address John Santiago 20805 S. Birchwood Loop Rd. Chugiak, AK 99567 Date Estimate # 2/11/2021 35 Signature Phone # E-mail 9076946454 jrsseptica gmail.com Project Description Qty Rate Total Septic tank installation and excavation at 20805 S. Birchwood Loop 1 62,849.00 62,849.00 Rd. Including well abandonment confirmation, tank replacement, exploratory digging for edge of field by tank, rerouting water lines to house per permit, removing existing septic tank by 1986 field, and backfilling seepage pit by house per permit. I look forward to working with you! Total $62,849.00 Signature Phone # E-mail 9076946454 jrsseptica gmail.com Northern Excavation and Construction, LLC 15861 South Birchwood Loop Road Chugiak, AK 99567 (907)694-1373 NorthernExcavation@GmaiI.com 1752 01/20/2021 1 I JI V III VV %JlLtl J L- 1 -GJ 20805 S BIRCHWOOD LP Thank you for the opportunity to provide you with this estimate. Changes which increase the specific tasks of machine/labor time spent of this contract, will be submitted in writing by the owner and accepted by the contractor and the contract modified accordingly. Payment to the Contractor for modifications to this contract which increase the work will be charged. All agreements are contingent upon accidents, design changes, or delays beyond our control. Northern Excavation & Construction, (NEC) shall not be held liable for the affects that may occur to the property during and after the install. Affects such as damage and structural integrity of decks or deck supports in or close by the work zone, trees left in close proximity of where machine work takes place or having to stock displaced excavated material around trees to be retrieved, damage and structural integrity of retaining walls that may need to be partially removed or traveled close too, disturbance to driveways, disturbance to any landscaping, etc. All methods and materials shall be in accordance with MOA regulation. Payment in full is due upon completion of backfill. Payments received after 30 days of completion shall be charged a 1.5% monthly fee on unpaid balances. Services TANK REPLACEMENT: Install new 1250 gallon septic tank and remove both existing tanks in accordance with engineered and MOA approved design. INCLUSIONS: 1250 gallon Greer tank w/ riser kit. Bedding material. Pumping. Disposal of tanks offsite. Fill in existing crib. Pipe/Supplies. Machine/Labor/Compaction time. Services 1985 WELL: Install new waterline from existing well stubbed up under the footing of existing home. INCLUSIONS: 1 inch copper tubing. Conduit. Well wire. New pitless installed. Machine/Labor time. Please note that a 48 hour notice to start digging is required by the State of Alaska for utility locates. 29,740.00 10,570.00 1982 W -1-L: Instal► new waterline from existing well stubbed up under the footing of existing home. Straighten or replace portion of casing. INCLUSIONS: 1 inch copper tubing. Conduit. Well wire. New pitless installed. Machine/Labor time. 'Northern Excavation and Construction, LLC is not liable for any utility lines not located by 811 public utility locate e.g., any lines running to detached structures. Please notify contractor of any power/gas/communications lines, prior to starting the job, so private locate services can be called. An extra charge will be incurred for private locate services. Accepted By Accepted Date Please note that a 48 hour notice to start digging is required by the State of Alaska for utility locates. Proposal ADDRESS John Santiago 20805 South Birchwood Loop Chugiak, AK 99567 ARM Septic Services, LLC 17933 Old Glenn Highway Chugiak, AK 99567 (907) 688-9433 ARMServicesAK@outlook.com www.ARMServicesAK.com PROPOSAL # 1735 DATE 02/15/2021 ACTIVITY QTY RATE AMOUNT Excavation 1 15,726.00 15,726.00 Installation of a new septic tank, and proper abandonment of old components per the terms of Proposal 1729. Please read and sign the "Residential Addendum A" provided as it applies to this contract. All work on this estimate/proposal shall require at least a 60% deposit. Excavation Excavation site work for new water lines and associated work. T&M (time and materials) rates of $2495/day shall apply for heavy equipment, operator and laborer. All work shall be billed out accordingly based upon the actual amount of time spent working onsite, plus materials (with markup). (If additional site work is required, see specifications as outlined in proposal 1730) Site Work Well and water system work per specifications outlined on AWPS estimates 20206045 and 20211031 to include well abandonment and water system work. These rates are based upon a typical well depth of 150'. If the well(s) to be abandoned are found to be abnormally deeper, additional charges will apply. 15,600.00 15,600.00 28,613.00 28,613.00 By signing below, the client agrees to the proposed work, terms, TOTAL $59,939.00 and price. The client has also read and signed the "Residential Addendum A" and agrees to the terms. The client acknowledges that ARM Services, LLC has the right to lien this property. Accepted By Accepted Date ARM Services, LLC