HomeMy WebLinkAboutT15N R1W SEC 8 LT 112 Address: Phone: Municipality of Anchorage . Page _1 .ot;~ DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION' P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well"lns'pectiori Report · ~ ,,,.,~ '~ ~'.0 1 ~'O RID Numberi'- 0"~1'~'1~1'~7'0 '" Permit Number: -,.> ---- No. el Bedrooms: LEGAL DESCRIPTION LOt: ~ ~"~'~ To,~.~h'~:~ WELL; Bl°ck: t~,~ [~' ~,New [] Upgrade Tolal Deplh: ased TO: lot Ft. OO SEPARATION DISTANCES from astewaletSYstem: 'ECNew [] Upgrade ABSORPTION FIELD Trench [] Shallow,T,rench",':[D Bed [] Mound [] Other Deplh to pipe bogom hem origlnsl ~rade: Gravel depth benealh pipe Fill added above original grade: I Gravel 1eriCh: travel width: / Number el Lines: Surface Water Size in [lallona: Lot Line ) on" level at: Foundalion Curtain t'4/~ Drain Remarks: ¢:~o ~ L. g ',~ I ~ v~,-~.,,..,-¢ AC P6-,~ ~J) alien and Descrlptiom TANK Septic [] Holding [] S,T.E,P. tuber of Compartments: LIFT STATION High water alarm at: Electrical Inspections performed by: BENCH MARK Inspections performed by: '--~-'~- ~'~""~5'~- Dates: lst~ Department of Healft~h a,.nd Human Serwces app~ova~ Reviewed and approved by: ~/"/~"~/~ '¢'?~ . Date:-/-//~ ~o Permit No. ~./q~'o ~'(:) Page . ~ of ~ Municipality of Anchorage DEPARTMI-'NT OF HEALTH AND HUMAN SFRVICES ENVIRONMENTAL SI-'RVICES DIVISION', .... .. P.O. Box 196650 · Anchorage Alaska 99519-6650° Tslepbone: 343.-4744 O,*~Si~e Wastewater Disposal System and/or Well n~pection' Report. '. Legal De~ ,'iption: :~ID NO.:. ~ .O'E;'I- I'¢'/-"?-~ o~ e/o Alaska Water & Wastewater Seru~ar~c. "Preserving The Last Frontier" F~X: 338-3246 ~%, J DATE: __ g ~ NUMBER OF (Including Cow~r) TO:' ~. ~, A ~ ~ FROM: ~ ,._-:- ~S~GE: ~45,..,- - .,..: ~/~ .~ . . _~ ,., O~ner/Consul tant~ ~ '~l~ ~ Telephone: (907) 337-6179 · Fax: (907) 338-3246 · 8471 Brookridge Drive · Anchorage,-Alaska 99504 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519 6650 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PAGE 1 OF 1 PERMIT NUMBER:SW950150 DESIGN ENGINEER:ALASKA WATER & WASTEWATER SERVICES OWNER NAME:WILD RODNEY L & BETTSIE M OWNER ADDRESS:20726 JAYHAWK DR. CHUGIAK. AK 99567 DATE ISSUED: 7/11/95 EXPIRATION [lATE: 7/11/96 PARCEL ID: 05115120 LEGAL DESCRIPTION: T15N R1W SEC 8 LT 112 LOT SIZE: 108900 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAAC80) . 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: // RECEIVED BY:_ / ~t~//~/~ ~ DATE: DATE: Alaska Water ~uly L, 1995 "Preserving The Last Frontier" Municipality of AnchoragE; Department ef Health and Human Sr~,rvioes Division of Environmental On-Site Services Section P.O. 8o× 196,650 Anchorage, ~laska 99519-6650 & Wastewater Services Fhe as1 Ref: New Well & Septic System at Lot ~12, Sec 8, T15N, RIW, SM, Chug{ak, ~laska.. -re whom it may concern: Attached is the application, site plan, 'For the sub3ect wei1 and septic system. tile proposed system are as fell. owe: and design drawings Comments rega rdio(j 1. PERCDLAT!ON TEST: The percolation teste for' this design were done=. by David R. Daybon, P.E., who is now deceased. It is my understanding that bhe homeowners may have a copy with his original signature on it, If necessary, they Call present it to your office prior to issuance of the permit. I inspected the site on 6/16/95 and monitored for groundwater. Both monitoring tubes were dry. During construction I will visually inspeob the soils to eneure that they are consistent with David Dayton's pencolation tesbs. 2. TRENCH DESIGN: As can be seen from reviewing the~ attached percolation test results, the soil "perked" 1.5-20 minutes/inch at the location proposed for the system.. Ibis corresponds to an application rate of .6 gpcl/ft2. Since the proposed home has ~ bedrooms, the total design flow is 450 gpd. Based upon this, the minimum amount of absorption area is 750 ft2. The propose(:{ trench is 2 feet wide, 5 feet deep and 75 feet long, providing an absorption area of 750 ft2. 3. SEPI'IC TANK: : The homeowner wants to install a t500 gallon septic tank rather than a 1000 gallon tank; 4. INSTALL~%TION TO BE DONE BY HOMEOWNER:: ]'fie homeowner has; expressed an interest in doing the installation himself. I informed him that he milZL need bo provide yeur office with a resume' outlining his construction experience, prior te issuance o¢ the permit. You should be receiving ~t shortly. Telephone: (907) 337-6179 · Fax: (907).338-3246 · 8471 Brookridge I)riw~ · Anchorage, Alaska 99504, 5. SLOPES: Tile lol; ~S generally flat in the area were the house and well are going to go. Zn the northwest corner the IcL, s~arting approximately a~ the ~00 foot we~l radius, and proceeding to the northwest property corner, topography drops off at abou~ 15~. the relative elevation ef the property corners are noted OR the 1" = 40' site plan. Ln summary, there are no slope CORCeI'RS N&~h ~ll8 proposed trench design. 6. SURFACE WATERS: I walked the area within 100 feet of the proposed septic system (6/16/95) and did not encounter any surface ~aters. I anl Ln]aNare ef any negative impacts that this installatien would i~/pose en adjacent wells, or sepl;ic systems. If you ave any question, pleaee call Be 8 357--6179. Sincerely, ]~ ~ O~n~r/~msu ~nt Wildl. wps , A. Game. oF-' M~.~.I M',,'M ~ July 22, 1994 Betsy Wild Jayhawk Dr. Chugiak, Alaska 99567 Dear M~s. Wild~ P~r your ,request we have excavate~ test ho~es, done ~erc: tests a bour~ary survey on Lot 112, Sec 8, ~15N, R1W, S.M., Alaska. The test holes w~re dug to a dept~ of 14 ft. No 9~ound wa'l~_~T,' during the ~eavatLon or after ~l.e mar~atory 7 day monitoring ~e~'iod. No water.was four~! on July 19,~994'wh.,en the final bollnd~ry survey work wa~ done. Both holes had Pe~:c t~t r~uits '~a~isfa¢;tory for septic Enclosed are c~pies of the soils information as well as the survs~ If there are any q~ e.stions~ please call. I OEPA.RZ,.ME.NT OF H~LTH & HUMAN ~RvIcE~' ....... .' · SOILS LOG -- PERCO~T ON TEST PERFORMED FOR; LEGAL DESCRIPTION:. ~1' t.~AJ ~.IUJ Township, Range~ Secti.0n: . 10 ~ ' ...~ WAS O~OUND WAT~a ' ENCOUNTERED'/ ,, //~ m ' 11 ~2~ IF YES. AT WHAT ~ ' . 14 - [~ o~ Reading Date ', Gr0~s Net Depth ~ ..... -[, Nat:. r ~9 PERGO~TION RA~E laut~lnc~) P~R~ HOL~ ~IAMST~ ~ ~/ . TEST RUN eETWEE~ ~ FT AND __ ~.FT COMMENTS DavJ~ R, DaylOrl P~ .... ~ .... PERFORMED ~y; .... Chucl~a~,. _ _. A[a~_ ~. .... I .. ..... CERTIFY THAT THI~ T~'r WAS PERFORM~b ACCORDANCE WITH ALL STA~E IN EFFECT ON THISDATE, qATe .' ~r ' ~.~ -' ~UIDELINE~ 72-~ (R~. 4/~) pERFORMED FOR;.. 9- 10 11 12 1:3- 14 16 17 18- 19 20 14:23 MASON & GRIFFIN 'P.O? DEPARTMENT OF HEALTH & HUMAN SERVICES Township, ~ange, Seotlo~: ~NCOUNT~RED? Water Afte~/'A'~ Zro ' Nat Depth ~.~ Net Reading [)ateline Tille _ W~tar ~ DrOF --- _. PERCOLATION RATE ~ {mlnule~lnCh) eBRO HOLE DIAMBTER David R, Dayton P.E. TEST RUN BETWEEN 4~ FT AND COMMENT~ 20~'10 ~aI~r ~t. . ¢hugl~k~ Alaska 99S67 PERFORMED BY: ACCORDANCE WiTH ALL STATE AND MUNICIPAL GU~DELINE~ IN EFFECT ON THIS OATE. DAT~ ~ ~ ~.1~_ _ 72.008 {Rev. 4/~5) hereby certify thor I hove surveyed the folfowtng described ~rop~rt:,', ~ //~L A-n~'h-~'r]ge R~¢or~lln~l ~acinct, ~l~k~ ~ ~o improve- ' merits situated thereon are withlnlhepro~Hyll~et enddo net overlap or enc~oagh on the p~opert~ yl~,~ ~dJ~ent thereto~ th~t noimpr~vements on,pro~rt~lylng adJaoont thereto enorooch on the premJ~n queshon and thql there am no ro~dw~ys, trqnsmlsslon lines or other vls~ble e~sements on s~ld property except as indicated hereon, Dated at Chu91~ Alaska D~ivld R, Doylon / ~ ~::~',':D~' W.O, Rodney & Bettsie Wild 20726 Jayhawk Dr. Chugiak, Alaska 99567 907-688-9453 Municipality of Anchorage Department of Health & Human Services On-Site Sewer/Well Permit Application RECEIVED JUl.. 1 3 1995 MunJc~pahly ol Anchorage Dept. Health & Human Services Re: Rodney & Bettsie Wild's On-Site Sewer/Well Application Legal Description: Lot112, Sec 8, T15N, R1W, SM, Chugiak, Alaska To Whom It May Concern: This letter is in regards to our on-site sewer/well application. As indicated on our application, we plan on putting in our own system. We feel capable of perforlning the work for the following reasons: 1. My husband is knowledgeable in operating heavy equipment as he worked for Cook Inlet Pipeline as a utility pipeliner. Duties included operating vm'ious pieces of equipment such as dozers and backhoes. 2. Our father will be assisting and has experience as he installed his own system. Hopefully the above information is adequate in the issuing of our permits. If not, please contact me at 274-5546 for additional information or any questions you may have. Sincerely, Bettsie M. Wild