Loading...
HomeMy WebLinkAboutT15N R1W SEC 8 LT 124Onsite File T15N R1W Section 8 Lot 124 #051-154-07 Municipality of Anchorage Page ► of DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Permit Number: SW �7��39 PID Number: os��syo7 Name: le Wastewater System: ❑ New 'Upgrade Address: Z123/i T ltrw�' pr �+� i�� /�il� 99l'�i ABSORPTION FIELD Phone: No. of Bedrooms: 3 ❑Deep Trench ❑Shallow Trench XBed ❑Mound ❑Other LEGAL DESCRIPTION Soil Rating: D Total Depth fromor/i�inalgra de: y,O ��i�/L•O �'Ck GPD/Sq. Ft. Lot: Block: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe ��.� �• insii Ft. � � Ft. Township: %lS� Range: Section: Fill added above original grade: (. O Gravel IeVh: 1/7 Ft. Ft. // WELL: Fit= ❑ New OUpgrade Gravel width: 1S,31 Number of lines: Distance between lines: y.s- P14HS --e,41 5%T<- Svd-S. Ft. Ft. Classification (Private, A,B,C): Total Depth: Cased To: Total absorption area: 6Y5- Pipe material: lFg7te, 11A 3--'13�1 DRi✓Arr= Ft. Ft. SO. Ft. �ccrL� C Driller: Date Drilled: Static Water Level: Installer: pp— 0609 Date installed: Ft. %'✓a Yield: Pump Set at: Casing Height Above Ground: TANK GPM Ft. Ft. SEPARATION DISTANCES Septic ❑ Holding ❑ S.T.E.P. To Septic Absorption Lift Holding Public/Private Manufacturer: Capacity in gallons: From Tank Field Station Tank Sewer Lines HL�iJ. /rje,, k �p40 Well 1 7-s- 138 "� // 4 ! / ^ /V f� Material: TE-E_SurfacL Number of Compartments: �- +iso LIFT STATION Water Lot O qZ3J 2 I �O i Size in gallons: Manufacturer: Line Foundation l/ ' /t/,� "Pump on" level at: "Pump of " evei a' High water alarm at: curtain ��� � } Pump Make el I Electrical Inspections performed by: Drain Remarks: ,2 ,/PEC fi ro��!i�• s�� BENCH MARK Location and Description: Assumed Elevation: / O!�; 40 Ft- ENGINEER'S SEAL / .low � ..�` OF A�►t • �% Inspections performed b : F� E s 6- 23-577 p p y Dates: 1 st •cb a• 6V * % 2nd 6- 2s �� 49Ili . "f...,s...«.«.«.......... Department of Health and Human Services approval Loufs A.Butera ; % d Reviewed and approved by: Date: F`-( anal tc CE -6736 0I +'�}•• •�.•• 1 72-013 (Rev. 9/91) MOA 25 vV �`�wy��srCk of 2 Permit No. SW970139 Page 2 Municipelity of Anchoroge DEPARTME-"NT OF HEALTH AND HUMAN SERVICES FNVlRONMI=NTAL SERVICES DIVISION P.O. Box 196650 · Anchorege, Alasko 99519-6650 Telephone: 345-4744. On-Site Wastewater Disposal System and/or Well Inspection Report Legal Description: Lot 124 T15N R1W ,Sec 8 PID No.: 05115407 N Bgd57'0" E 329.90 ~ TEST HOLE / 1000 --- ~,~SC~E~T LWL SEPTIC TANk TH 1 ® /°o. ,X4.3' A C -- 24.7' FILTE~ 5AND B C - 4g,.2' LAYE¢~ A-D -- 72.1' ~ ~ C = 70.5' ABANDONED z u 5EPTIC 3 ~ TAN~ ABANDONED SEPTIC AREA EXISTING WELL TO BE ABANOONED NOTE: EX[SlING HOUSE IN PI~OCE55 OF BEING I~EI'iOVEI) 329.90 S 89d57'0' W WELL LOCATION SCALE 7/1/98 1" = 60' 89.5 �rrttffirb DAttn I' 1 by '.-�VIECEIVED DOC Co, dba SULLIVAN WATER WELLS JUN 2 4 1998 P.O. BOX 670272, CHUGIAK, ALASKA 99567 * TELEPHONE 688-2U9MUl'l:0ipality of Anchorage ept, Health & Human Services OWNER OF LAND DEPTH OF WELL ADDRESS CO IlY LEGAL DESCRIPTIO DATE - Started Ended PERMIT NUMBER 44 KIND OF FORMATION: STATIC LEVEL OF WATER FT. bRAW DOWN FT. GALS. PER HR KIND OF CASING From Ft. to Ft. to _—Ft Ft. to i J I C From Ft. to Ft. From From Ft. to Ft. Ft. Froi-n —Ft. to Ft. From Ft. to 0 Ft. From Ft. to Ft. From Ft. to Ft. S' From —Ft. to Ft., From Ft. to Ft. Y From Ft. to Ft. From Ft. to Ft. "4xi, __r;�04,lj From Ft. to Ft. From--.- Ft. toL.L­� Ft. From Ft. to Ft. '–Ft. From L Ft. to i Ft. i "j From to Ft. 'I 4 %.JFrom Ft. Ft., From Ft. to , Ft. to From 5--i Ft. to`, "2,' Ft. J4-:jU'.1c,11Z .V,�LJ-r'9 From Ft. to Ft. From---! Ft. to '2 F t. From —Ft. to Ft. From Ft. to _,Ft. From Ft. to Ft. From Ft. to Ft. From Ft. to Ft. From Ft. to Ft. From Ft. to Ft. From Ft. to Ft. From Ft. to Ft. MISCL. INFORMATION: From Ft. to Ft. From Ft. to Ft. From Ft. to Ft. From Ft. toFt DRILLER'S NAME PAGE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALAS[CA 99519-6650 ON-SITE WELL AND WASTEWATER DISPOSAL SYETEM PEP, MIT PERMIT NUMBER:SW970139 DESIGN ENGINEER:EAGLE RIVER ENGINEERING SERVICES OWNER NAME:BISSELL CLIFFORD V & JANE ANN OWNER ADDRESS:21234 JAYHAWK DR CHUGIAK, ALASKA 99567 DATE ISSUED: 6/17/97 EXPIRATION DATE: PARCEL ID:05115407 LEGAL DESCRIPTION: T15N R1W SEC 8 LT 124 LOT SIZE: 108900 (SQ. FT.) NUMBER OF BRDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAl, FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: THE ATTACHED APPROVED DESIGN. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SANE DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING THE FOLLOWING SPECIAL PROVISIONS. 1 OF 6/17/98 SPECIAL PROVISIONS: [ ECEIVED BY: DATE: [ agle I iver P.O. Box 773294 Eagle River, AK ))577-3294 Engineering Louis Butera, P.E. ervice s (907) 694-5195 tel (907) 694-3297 fax May 23, 1997 Jim Cross, P.E. Manager, On-Site Services Municipality of Anchorage P.O. Box 196650 Anchorage, AK 99519 BLMlot 124 T15nRlw Sec 8 Narrative & Permit Application Dear Mr. Cross: The proposed well and septic system will have very limited impact on adjacent properties for the following reasons: 1. The surrounding lots are large, allowing sufficient room for septic sites. 2. Immediate neighboring septic systems are all +30' distance. 3. Reserve space is adequate, due to absm!otion capacity. 4. Drainage will not be affected and is not a major consideration in our design. If you have any questions please call our office at 694-5195. Sincerely, Louis Butera, P.E. / \1997\97-030-NAR.DOC ~ 'rHt .5eP'nc. TANK ~Q ~-,- , i ~ ' /~" P~OP J AR~ .- WELL TO A~AN DON NOTE: ~ISTING HOUSE TO 5~ ~EHOVEO S 89d57'0' ~ / ~ TEST HOLE J MONITOR ~BE a S~ER C~NOUT ~ ~. - WELL NO SURFACE WATER ~- ~SEMENT ;~:'..~ . NO KNOWN CURTAIN DRAINS ~--~ PROPOSED ~CHFIELD .... ,,~ ..... ~- ~I~ING L~CHFELO OWNER: BISSEL ';:' - CONTRACTOR:::.NfA .. · . . ~ ~.'' JOB~ 97-050 IDATE: 5/29/97 I SCALE 1" =.6~ ~~~""~ .. ~ P.O. Box 773294 ~ EAGLE RIVER, AX 99577 '*;% "" .... '" ~ ~ ~ (907) 694-.5~95 FAX: (907) 694-3297 EAGLE RIVER ENGINEERING SERVICES P,O. Box 773294 Eagle River, Alaska 99577 (907) 694-5195 ERES Project No,: 97-030 Calculated By: LB Date: 5/21/97 Legal: BLM LOT 124 TI5N R1W SEC 8 Single Family 3 Bedroom Dwelling TEST HOLE1 Bed Subsurface Wastewater Disposal Field Water' use at 150 gallons per bedroom = 450 gallons Percolation rate = 0.3 minutes per inch Wastewater application rate = 0.7 gallons per day per square foot Required absorption area = 643 square feet Bed width(W)= 15 feet Gravel depth (D) = 0.5 feet Required length = Required absorption area / Bed width Required length = 643 / 15 Required length = 43 feet Total Excavation Depth = 1.5 feet 2' APPROVED FILTER SAND LAYER REQUIRED BELOW SEPTIC ROCK SINGLE FAMILY ON-SITE WORKSHEET ERRS PROJECT NUMBER: 97-030 CALCULATED BY: LEGAL DESCRIPTION: BLM LOT 124 T15N RIW SEC 8 NUMBER OF BEDROOMS: WATER USE PER BEDROOM: PERCOLATION RATE: DEPTH TO GROUNDWATER: DEPTH TO IMPERMEABLE LAYER: ANTICIPATED DEPTH OF COVER: MOUND OR BED SYSTEM WASTEWATER APPLICATION RATE: ABSORPTION AREA REQUIREMENT: MINIMUM BED LENGTH 12 FEET WIDE BED 15 FEET WIDE BED TRENCH SYSTEM WASTEWATER APPLICATION RATE: ABSORPTION AREA REQUIREMENT; SHALLOW TRENCH OPTIONS 5 FEET WIDE TRENCH LB 3 150 GALLONS 0.3 MINUTES PER INCH 6 FEET 10 FEET USABLE SOIL STRATA 1 FEET TOTAL USABLE DEPTH: USABLE SOIL STRATA DEPTH: 0.7 GAL/SQ.FT 643 SQ.FT 2 1 54 FEET 43 FEET N/A GAL/SQ.FT #VALUE! SQ.FT DEEP TRENCH OPTIONS 3 FEET WIDE TRENCH EFFECTIVE REQUIRED TRENCH EFFECTIVE REQUIRED TRENCH DEPTH (FT) ENGTH (FT) DEPTH (FT) ENGTH (FT) 1 #VALUE! 4 NA 2 NA 4.5 NA 2.5 NA 5 NA 3 NA 5.5 NA 3.5 NA 6 NA 4 NA 7 NA 8 NA 9 NA DESIGN SPECIFICS FIELD SYSTEM: GRAVEL DF' PTH: TRENCH OR BED WIDTH: LENGTH: TOTAL EXCAVATION DEPTH: B (B=BED, S=SHALLOW TRENCH & D=DEEP TRENCH) 0.5 FEET 15 FEEl' 43 FEET 1.5 FEET Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 525 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG .-- PFRCOLATION TEST PERFORMED F 0 R: __,~/~')"~_//' LEGAL DESCRIPTION: I,?.. y Township, Range, Section: 1 2 3 4 5 6 7 8 9- 10- 11 12 13 1,4 15 16 17 18 19 20- SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? /V~ IF YES, AT WHAT / DEPTH? Depth to Water Alter i'donitoriflg? ~ Date: Reading Date Gross Net Depth to Net Time Time Water Drop PERCOLATION RATE L~'~ [m,nutes/,nch) PERC HOLE DIAMETER (~ '/ TEST RUN I~ETWEEN ~:-.-- FT AND ~ F'r I ' ~'~"~ ~'~ ~'~'"~'~'~'"'""~ ~'~ CERTIFY THAT THIS TEST WAS PERFORMED IN PERFORMED BY: ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE DATE: E gle River Engineering Louis Butera, P.I~. P.O. Box 773294 Eagl~ River, AK 99577-3294 ervices (907) 694-5195 tel (907) 694-3297 f,,× SPECIFICATIONS FOR ON-SITE SEPTIC SYSTEM LEGAL: BLM lot 124 T15N RIW Sec 8 5/23/97 A. GENERAL 1. The well & septic phm is for a single family residence ooly. 2. The drawing and or site plan shall be a part of this specification. 3. All materials and workmanship shall meet the Anchorage Department of Health reqairements. 4. All soil tests are advisory to tile design and are to be verified or modified in the field by the engineer. 5. All excavations and depths are advism3' aod are to be verified in the field by the contractor to meet Municipality of Anchorage requirements. 6. It is the respoosibility of the owner to obtain all necessary permits or easements and to locate any adjaceot multi-family wells. 7. The excavation is to be exactly in the area shown on the site plan, any deviation requires engineer approval. 8. It is always recommended that a surveyor locate the nearest lot line position and the location of any easements. 9. Any remaioiog open test hole excavations shall be filled. B..SEPTIC TANK 1. The septic tank shall be a minimum of 1000 gallons and shall be of approved MOA design. C. BED 1. The bed is to follow the natnral land contour to maintain uniform total depth of the bed bottom. 2. The bottom of the bed shall be level, plus or minus 1.5". 3. A 2' filter sand layer shall be required at a total depth of 4'. Material shall be an ADEC approved filter saod. 4. The total depth of the gravel layer is oot to exceed 0.5' at any poiot. 5. The effiuent liue is to be 3034 PVC fi'om the taok to the bed, and FSI0 perforated pipe within the bed. 6. The bed gravel is to be covered with typar fabric material. 7. Soil or combination of soil and extruded board insulation to a depth of 3' or equivalent is to be placed over tile bed. Mounded side slopes not to exceed 3:1. 8. The septic tank and leachfield must not be closer than 100' to aoy existiog private well, 150' to any Class "C" well, or 200 feet to any commuoity well. RECOMMENDED LEACHFIELD DIMENSIONS: BENCHMARK - 100.00 ASSUMED DATUM at flagged uail in tree BOTTOM OF 2' FILTER SAND LAYER = 4' BELOW GRADE BOTTOM OF GRAVEL LAYER = 2' BELOW GRADE' SAND FILTER THICKNESS -- 2' of ADEC approved material GRAVEL THICKNESS = 6" under pipe, 2" over pipe BED LENGTH -- 43' BED WIDTH = 15' SOIL RATING = 0.7 GPD/ft5 BEDROOM CAPACITY = 3 SEPTIC TANK = 1000 gallon Twenty-fonr (24) hours notice required for all inspections. \1997\Bed-sa-l.doc MUNICIPALITY OF ANCHORAGE Development Services Department �`' p P �- =- Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 051-154-07 1. GENERAL INFORMATION Complete legal description T15N R1W SEC 8 LOT 124 Expiration Date: 3 ^2I - 20 Z Z Location (site address) 21234 JAYHAWK DRIVE, CHUGIAK AK 99567 Current property owner(s) Mailing address Real estate agent LIFFORD V. BISSEL PO BOX 670033, CHUGIAK, AK 99567 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone Day phone 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well ® Private Septic Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Received by: COSA to be released to the engineer, unless otherwise requested by the engineer. Date: COSA Fee $ Waiver Fee $ Date of Payment f 5 ZO2 1 Date of Payment Receipt Number 715 15 7 Receipt Number COSA # 0SC 2 11 '7 1 '7 Waiver # Distance: 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm FIRST WATER CONSULTING Phone 907-350-9566 Address 13030 SUES WAY, ANCHORAGE, AK 99516 Engineer's Printed Name _CURTIS HUFFMAN, PE Date 12/15/2021 Comments: This investigation was completed in compliance with MOA guidelines, regulations, and best industry practices / methods. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year, quality of construction (workmanship & materials), the water usage of the family being served by the system and maintenance. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, any estimate of how long a system will function satisfactory ��Q: •' • . • �) for current or future occupants or guarantee that no unseen encroachments, deficiencies or rg• '.9 `r discrepancies exist can be given by First Water Consulting & % *: TH Fwrs �. .. .......� 6. DSD SIGNATURE" ��'•. "" '...." • • Curtis Huffman System #1 Approved for bedrooms CE 128991 -,����� 4_•12/15121-�f System #2 Approved for bedrooms �1,F�'°ROFESSIONP 4 Disapproved Conditional approval for bedrooms, with the following stipulbin �t�d WA pg"TR Z� v''ATE o Original Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Adviso y Well Flow Advisory Other _S�+tfa le K Legal Description: T15N R1W SEC 8 LOT 124 Parcel ID: 051-154-07 If more than 1 septic system on lot: COSA Checklist # A. WELL DATA ® Well log is filed with Onsite (or attached) Date drilled 6/1997 Total depth 120 ft Cased to 72 ft ® Sanitary seal is functioning correctly ® Wires are properly protected Casing height (above ground) 18+ in. Date of flow test for COSA 12/7/2021 Static water level at beginning of test 28 ft. Comments B. TANK DATA Age of tank(s) 24 years Tank type/material SEPTIC / STEEL Measured operating fluid level in septic tank 49" ® Standpipes/foundation cleanout per record drawing Date of pumping 12/6/2021 D. ABSORPTION FIELD DATA Which system tested (date installed) 6/23/1997 ❑ ALL standpipes present per record drawing Total measured depth from grade *3_9 ft (max) Measured depth to pipe invert from grade *3_3 ft (min) ❑ N/A — pressurized field ® Monitor tubes go to bottom of effective. If not, state depth into effective of — Structure served by this system _ Well production at time of test 2+ gpm Water storage tank volume NA gallons Well disinfected for coliform test? ❑ Yes ® No ® Coliform bacteria is Negative Nitrate 1.96 mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ® Arsenic less than MRL (ND) NES Collected by ' Date of Sample 12/8/21 C. LIFT STATION ❑ Required maintenance completed Age of lift station — years Lift station material Comments: SEE MOA TANK ADVISORY Adequacy test date 12/7/2021 Results 2 Pass For 3 bedrooms Fluid depth prior to test 0 in Water added 600 gal New depth 4 in Elapsed time 1330 min ® Code -required soil cover over field W/ INSULATION Final fluid depth 0 in ® System presoaked Absorption rate 450 gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) N date of test) — Gallons introduced 2000 gallons If yes, enter date Comments/Deficiencies: *AT MT & CO. ELEVATION SHOTS TAKEN SHOW 0.79-1.23' ED BELOW LATERAL. F- Surveyor missed pipes under snow - all pipes located per MOA record IR. E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' El Yes if No ft Wells on Adjacent Lots: Community Sewer Manhole/Cleanout > 100' ® Yes if No ft ® Yes if No Neighboring Tank > 100' ® Yes if No ft Private Sewer/Septic Line > 25' ® Yes if No Absorption Field on Lot > 100' ® Yes if No ft Holding Tank > 100' ® Yes if No Neighboring Absorption Fields > 100' Surface Water > 100' ® Yes Animal Containment > 50' ® Yes if No ® Yes if No ft Community Sewer Main > 75' ®Yes if No ft Manure/Animal Excreta Storage > 100' ® Yes if No From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ® Yes if No ft Surface Water > 100' P rt L' ft ft ft ft 111 ® Yes if No ft rope y ine > 5 El Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' ® Yes if No ft Private Wells > 100' ® Yes if No Water Main > 10' ® Yes if No ft Community Wells > 200' ® Yes if No Water Service Line > 10' ® Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ® Yes if No ft If absorption field is under driveway comment below Property Line > 10' ® Yes if No _ ft Wells on Adjacent Lots: Water Main > 10' ® Yes if No ft Private Wells > 100' ® Yes if No ft Water Service Line > 10' ® Yes if No ft Community Wells > 200' ® Yes if No Surface Water > 100' ® Yes if No ft F. ENGINEER'S COMMENTS ORIGINAL WELL DECOMMISSIONED BY COLE SULLIVAN DECEMBER 2021. G. ENGINEER'S CERTIFICATION l certify that l have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. ft ft Septic Tank Advisory Certificate of On -Site Systems Approval #OSC211717 Subdivision: T15N R1W Sec 8 lot 124 Starting at 20 years of age the MOA issues Advisory's for steel septic tanks. The septic tank for this property is 24 years old. Typical replacement costs range from $9,000 to $12,000 This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. This is an example of what the metal of a 20 -year-old steel tank MAY look like. 100 Cn U7 Oo O W r7 M > N' z O Li! ct� a U t1) 00 Oo Z0 z a X w V) w X 3i 0= 0 V) BASIS OF BEARING N89°57'00"E 329.72' (329.93' R) _ JAYHAWK DRIVE 50' R.O.W. RESERVE HCP RAMP • ®� r GRAVEL SEPTIC• w Z W w D/W VENT a r C a (tYp) O o -Z to t O RO r a.o ab SHED LOT 124 N89`55'12"E 329.69' (N89°56'30"E 329.97' R) ANCHORAGE RECORDING DISTRICT, ALASKA AS -BUILT OF: BLM LOT 124 T15N R1W SEC8 S.M. BLM PLAT MAY 13, 1955 SURVEY CERTIFICATE: I, John L. Schuller, Have conducted a physical survey of this property as shown on this drawing and that the improvements situated hereon are within the property lines and no enchroachments exist other than noted. Under no circumstance should any information on this drawing be used for construction of fences, structures, improvements, or for establishing boundary lines. EXCLUSION NOTES: It is the owners responsibility to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. DEC 14, 2021 1"=50' 1 schulleer6uk.net 21-169 eoacirAM JLS N W1257 220108 SHED 8:0' 0 0 SHED = FND MONUMENT ® = FND 5/8" REBAR OF 4 i " % J�p 1,HN L. SCHULLER; LS -10408 fessiono� Low M ry to 0 M 0 U O n P r - O 00 z0 z O L NDSa4l�g �} R 0C� 1831 Taikeetna Street Anchorage, Alaska 99508 (907) 227-1455 office (907) 274-4992 fax Municipality of Anchorage Community Development Department On -Site Water & Wastewater Program 4700 Elmore St. ® P.O. Box 196650 w Anchorage, AK 99507-6650 m www.rnuni,orgZonsite m (9071343-7904 Legal Address: Subdivision -j Block Lot T_ R i (, Section Lot Ig L� On-site Water & Wastewater Program certified contractor performing the well decommissi7nin : Name:, , i i I `1 Signature A AGb(-6U11 ) r Company:f<<t+i Well decommissioning date: o! r Method of decommissioning: AMC 15:55.0601-1 a. ❑ b. ❑ c. i Location: Use the space below to provide a drawing of the property showing the following items; • North Arrow • Decommissioned well, • Other water wells on the property, • Two separate swing -tie distances for each well shown in the drawing, Note: The swing -tie distances shall be measured from either permanent structures of property corners. ----- -- __ :�O,yi1u LJ 1, Tarr