HomeMy WebLinkAboutT15N R1W SEC 5 LT 21
Municipality of Anchorage Page I of 2_
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: ~W'c/c~0.~Z-7 PID Number: ,,"~5"/~.~2. ll
Name:
~-¢~'~7' ~ ~ur~ /~ ~ ~ Wastewater System: ~ New ~ Upgrade
Address: ABSORPTION FIELD
~o. ~ox ~7o~q
~U~/~, ~ ~ a Deep Trench ~ShallowTrench aBed DMound aether
Total Depth from original grade:
LEGAL DESCRIPTION ~ SoilRating: /.2 GPD/Sq. Ft.
Lot: ~ S~n: ]epth to pipe bottom fram original g~ade: Gravel depth beneath pipe
Ft.
Township:/~ ~ I""""> ~ Filladdedaboveoriginalgrade:. '', 7 Ft. Gravollength: *~ Ft.
~ ~ New ~ U pg rede Srave~ width: Number of lines: Distance etweea lines:
~Ft. / J ~ Ft.
WELL:
Classification (Private. A,B,C): Total Depth: Cased To: Total absorption area: Pipe material: F~/~
-- ~ V~ Ft. Ft. ~1~ SQ. Ft.
Driller: Date Drilled: SlaticWater Level: Installer: Date installed:
Yield: GPM IPump setat: Ft. ICasing Height Ab°ye Gr°und:Ft.TANK
SEPARATION DISTANCES ~Septic ~ Holding ~ S.T.E.P.
To Septic Absorption Lift Holding ~ublic/Private Manufacturer: Capacity iQ
From Tank Field Station Tank Sewer Lines ~C/~ ~ ~
Surface '~ ' I ~ LIFT STATION ~
Water /~ /~ ~ ~ ~
Lot , ~ ~ Size in gallons: ~ Manufacturer:
Line /~ ~ /~ ~
I
Foundation ~/, 7/1 ~ ~ ~ 'Pump on" level at:~ level at: J H,gh water alarm at:
CudainDrain '~0~ ~ ~ J Electrical lnspections performed by:
Remarks: BENCH MARK _
I Assumed Elevation:
17034 Eagle River Loop Road, No. 2~
inspections performed by: ~.1~ Liver. Alaska 995~ Dates: 1st /~ -Zo-e9
Department of Health,a ~H ceD approval '~;:': ...... ~ ·
Reviewed and approved by: ate: -*,:-~ z,::
72-013 (Rev. 9/gl) MOA 25
Permit No. SW940327
Page 2 of 2
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Descriptionl~OT: 21, SECTION 5, RIW, T15N PID No.: 05103211
Legal
C01i C02
N~W
lq00 GAL
SEPTIC
TA~K
N;T:S'."
A B
FCO 8.7 2,1
C01 5.9 2.8
C02 29.0~ 25.8
C03 34.~ 93.0
.CO~ 53~ 48.5
C05 53.~ 54.8
MT1 50,~ 57.9
50' E.0.~W. ESMT
NEW
NEW 1000 GAL. SEI~TIC
LOT 21i ~¢~
· FINAL GRADE
co~&
MT ii
C04
)4.5'
CO4&
91i5
· 85.~' NO WATER FOUND
lID
~o ~
PAGE 1 OF 1
MUNICIPALITY OF ANCHOKAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PER~4IT.
,olz 3:ooem
PERMIT NI/MBER:SW940327 DATE ISSUED: 8/31/94
DESIGN ENGINEER:S & S ENGINEERING EXPIKATION DATE: 8/31/95
OWNER NAME:SOUTER ROBERT D &
OWNER ADDRESS:P.O. BOX 670994MIELKE ST
CHUGIAK, AK 99567
PARCEL ID:05103211
LEGAL DESCRIPTION: T15N R1W SEC 5 LT 21
LOT SIZE: 108900 (SQ. FT.)
NUbK~ER OF BEDROOMS: 3 THIS PERMIT: 3
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AIqD THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 (24 HOURS)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS
RECEIVED BY:
ISSUED BY:
ROBERT SHAFER, P.E.
ROGER SHAFER, P.E.
August 12, 1994
CIVIL ENGINEERS
(907) 694-2979
FAX 694-1211
HEALTH AUTHORITY
APPROVALS
SEWER & WATER
MAIN EXTENSIONS
SEWER &WATER
INSPECTION
ENGINEERING STUDIES
AND REPORTS
WELL INSPECTION
& FLOW TEST
SITE PLANS
ROAD DESIGN
SOIL TEST
PERCOLATION
TEST
STRUCTURAL &
~IECHANICAL
INSPECTIONS
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
825 'L' Street
P.O. Box 196650
Anchorage, Alaska 99519-6650
REFERENCE: Lot 21, Section 5, T15N, R1W
Request you issue a per~it to drill a well and install a septic system
to serve theproposedthreebedroomhouse out he referenced property-
A test hole was excavated and a percolation test performed. The
approximate location of the test hole is located on the attached site
plan. The monitoring tube within the test hole has been checked and
found to be dry.
There are no protective well radii which encroach upon the property.
There are no points of contamination within the proposed well radius
which can be seen on the attached site plan. The proposed 1000 gallon
septic tank is to be placed outside the well protective radius.
This property has enough area for a future septic upgrade which can be
seen on the attached site plan. We do not anticipate any adverse
effects on neighboring properties by the installation of the proposed
septic system.
If you have any questions, or require additional information for your
ON SITE
WASTE WATER
DISPOSAL SYSTEM
DESIGN
17034 NORTH EAGLE RIVER LOOP ° SUITE 204 ° EAGLE RIVER, ALASKA 99577
0
+,OOI
0
d I
I
I
OVO~] q~AV~[D
N¥'ld 311S ,og =: ,,!-
U
]I¥.L3(]/NOIIO3S-XI
g
L~
'S'I'N
ON-SITE WA~T~NA~'~ DISPOSAL SYSTEM
CONSTRUCTION PRACTICES
and
MA~'~LIAL SPECIFICATI(XE%~
R~F~f~NCE: Lot 21, Section 5, T15N, R1W
The scope of this project includes the installation of a 1000 gallon
septic tank and a five foot wide drainfield to serve the proposed three
bedroom residence for the referenced property.
Construction shall be in accordance with the approved site plan and
design drawings, Municipal permit with any special provisions or
conditions, and all applicable State and Municipal Wastewater Disposal
Regulations.
The contractor shall be responsible for obtaining any necessary
underground utility locates.
Unless specifically agreed otherwise, the property owner shall be
responsible for final grading areas subsequently depressed from soil
settling. On all leachfield mound systems, the property owner shall be
responsible for ensuring a satisfactory vegetation growth over the
mounded area.
Contractors installing wastewater disposal systems must be certified by
the Municipal Health Department for system installations. Owners
installing their own systems must also receive prior approval from the
Municipal Health Department.
SEPTIC ~
1. A septic tank is to be constructed by a certified septic tank
manufacturer. Construction shall include two 4" cleanouts for pumping
access.
2. The septic tank shall be sufficiently bedded to prevent settling or
shifting of the tank.
3. Ail standpipes on the septic tank shall extend a minimum of 12 inches
above final grade.
4. Septic tanks installed with less than 4' of cover shall be insulated.
Page Two
Lot 21, Section 5, T15N, R1W
August 12, 1994
A foundation cleanout shall be installed one to four feet from the
building foundation. In the line between the tank and the leachfield
there shall be two adjacent cleanouts (unless an effluent pumping system
exists within the septic tank). These cleanouts shall be located on
undisturbed soil not more than 10' from the tank. The first cleanout,
in line, shall be to clean toward the leachfield. The second cleanout
shall be to clean toward the septic tank.
6. Final grading over the septic tank shall be such that a positive slope
exists away from the septic tank.
ABSORPTI(~ TRENCH/DRAINF~.D INST;~LLATION:
Excavate the proposed trench to the dimensions shown on the design. The
bottom of the excavation shall be within 2 inches of level. If the
sidewalls of the excavation become smeared, they must be raked or
scratched (roughed-up) before gravel (sewer rock) placement.
Once the gravel is installed, the distribution pipe is to be installed
level with the perforations faced downward. Gravel is then to be placed
over the distribution pipe to provide a minimum of 2 inches of cover
over the pipe.
o
A silt barrier must be installed between the final gravel layer and the
native soil backfill. Ensure the silt barrier covers the entire gravel
surface before placing backfill.
Monitor tubes shall be of four (4) inch diameter and installed
approximately in the locations shown on the design. The portion of the
monitoring tube extending through the gravel shall be perforated from
the bottom of the trench to the invert of the distribution pipe. This
is equivalent to the effective depth of the gravel as noted on the
design.
Backfill over the final gravel layer must not be less than twenty-four
(24) inches. Insulation must be installed when the backfill depth is
less than thirty-six (36) inches. The finish grade over the trench must
be mounded to prevent the formation of a depression after settling.
MINIMUM MAT~LIAL SPECIFICATIONS:
1. Any septic tank proposed for installation must be constructed by a
Municipally approved septic tank manufacturer.
Page Three
Lot 21, Section 5, T15N, R1W
August 12, 1994
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Type of Pipe Perforated
Solid
Cast Iron Yes Yes
ASTM D3034 (PVC) Yes Yes
ASTM F810 (HDPE) Yes No
ASTM D2662 (ABS) Yes Yes
Use of a type of pipe other than listed above must be approved by the
inspecting engineer.
3. Insulation shall be at least 2" thick extruded direct burial polystyrene
(Dow Chemical Company Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Fernco, or equal).
A permeable nontoxic silt barrier (Typar 3401, Mirafi 140/N, or equal)
must be installed between the final leachfield gravel layer and the
native soil backfill.
6. Ail leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel
with less than 3% passing the #200 sieve.
7. When sand is being used as a filter material, its gradation
specifications must conform to current M.O.A. or D.E.C. requirements.
INSPB~L-I~3.0NS:
Typically there will be a minimum of three (3)
installation of the wastewater disposal system.
follows:
inspections required during the
These inspections will occur as
1. The first inspection must be conducted after the excavation of ditches,
pits, trenches, or beds and before the installation of any gravel. A
septic tank may be set in place, but may not be backfilled before this
inspection.
2. The second inspection must be conducted after the placement of the silt
barrier, gravel, distribution lines, standpipes, cleanouts, and
insulation, but before the placement of any other backfill.
Page Four
Lot 21, Section 5, T15N, R1W
August 12, 1994
3. The final inspection is to occur upon final grading of the property.
Often there will be more than these 3 inspections required, especially with the
installation of multiple trenches, sand filters, pressurized distribution
systems, etc. Thus, the inspecting engineer is to be contacted at least 24
hours prior to the start of construction. If necessary, a pre-construction
meeting will take place on-site. The inspecting engineer will not coordinate,
direct or control in any way the contractor's activities.
The owner shall contract with the contractor to perform the work outlined in
these specifications and plans and in accordance with the attached M.O.A.
permit. There will be no contractual arrangement existing between the
contractor and S & S Engineering. S & S Engineering shall be the owner's
representative and will inspect the work as stated above to document the
contractor's activities. Final acceptance of the contractor's work rests with
the owner and the M.O.A.
S & S Engineering shall have no liability to the owner or to others for acts or
omissions of the contractor or any other persons performing work on this project
or the failure of the contractor to carry out the work in accordance with these
construction documents. S & S Engineering's inspecting engineer will not be
responsible for the construction means, methods, techniques, sequence,
procedures or the safety precautions incident to this project.
CONTRACTOR/INSTALLER
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
1
2
5
6
?
8
9
10
PERFORMED FOR: ~- '~ DATE
LEGAL DESCRIPTIoN:L(~)"~'O'~ !/ S~---~-- ~,/7'/~A-~./~l~J,T°wnshiP;LRo;r~ge' Section:
12
13
14
15
16
17
18
19
20
COMMENTSf~)~SM ~,. '~'~
(ENGINEER'S SEAL}
SITE PLAN
WAS GROUND WATE~
ENCOUNTERED?
IF YES, AT WHAT .~ 0
DEPTH? Pm
Monitoring? ~,-) Date: .
Gross Net Depth to Net
Reading Date Time Time Water Drop
~:d~ ~ ~YY
: f~ ~ ~ ~'/~ (y?"
; 2fl ~- ~" lye"
PERCOLATION RATE .
TEST RUN BETWEEN
(minutes/inch) PERC HOLE DIAMETER --
$ & S ENGINEERING
PERFORMED BY: 17034 Eagle River Loop Road NO. '~0~ CERTIFY THAT THIS TEST WAS PERFORMED IN
Eagle River Alasl(~ Y~tf~ll
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
72-008 (Rev. 4/85)
10/10/1094
15:49
90?6941211
S AND S ENGINEERING PAGE 02
10/19/1994 15:49 90?$941211 S AND S ENGINEERING PAGE 03
MUNICIPALITY OF ANCHORAGE
· DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street- Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
IPHONE I
LEGAL ~ESCR I?TJ ON ' -~
DISTANCE TO:
, ~ ] Well Dwelling PERMIT NO.
O Z ~ I Manufacturer Material Liquid capacity in gallons
~= ~jJ NO. of Ii.es / Length ~a~e Total ,~ ~nes Trench w~o' Mches"
~ : Top of tile to finish graOe~ -- Material beneath tilo /~ Cinches
Length Width Depth PERMIT NO,
~ ~ Type of crib Crib diameter C~i~ept~ I Total effective absorption area
m Well Building foundation Nearest lot line
~ DISTANCE TO:
~ ~ C~/~/~_ D~/~ ~ 7 ~ ~er Distancetolotline PERMITNO.
~ DISTANCE TO: ' ~ilding foundation Sewer line Septic tank Absorption area(s)
OTHER
PIPE MATERIALS
72-013 (Rev. 3/78)
DEF'ARTMENT OF HEALTH AND ENVIRONMENTAl_ F'ROTECTION
8:-25 L o]REE], ANCHORAGE, AK 99501
,~64-
(]tXl---~_-~ ]~ ]'E SIEI~J~ZF~ WELt.- PER~'~I ][ -F
PERMIT NO:
DATE ISSUED:
8426~7
07/26/84
APPLICANT: BOB SOUTE~
ADDRESS: % S&S ENGINEERING
EAGLE RIVER, AK 99577
CONTACT PHONE: 694-2979
LEGAL DESCRIP: SUBDIVISION: NA.
SECTION: 5 TOWNSHIP:
LQT SIZE: 2.5A (SQ.FT. OR ACRES)
MAX BEDROOMS." 3
LO"r: 2. 1 ~.,~..Obl ....NA
:L5N RANGE:
Listed below are th~=_ optior~s available to you
system. Choose thR option that best
DEF:'TH 'TO PIPE BOTTOM (FT.) 3.0 ** 3.0
GRAVEL DEPTH (FT.) 0.5 1.0
TOTAL DEPTH (FT.) 3.5 4.0
GRAVEL WIDTN (ET.) 14.0 5.0
GRAVEL LENGTH (FT.) 28.0 45.0
GRAVEL VOLUME (CU.YDS.) 14.5 12.5
TANK SIZE (GAL_S) ~000.0 .~,~ 1~000.0
SOIL RATING (SQ. FT./BR) 85 85
in designing your septic
fits your site,,
~,'~ DEPTH TO PIPE BOTTOM --':: 3.5 FT. REQUIRES INSULATION
· ~ DEPTH TO PIPE BOTTON < 4.0 FT. MAY I~~E:[..UII~E~ ' ~ ' ~' A LIFT STATION
~ TANK MUST NAVE AT LEAST TWO COMPARTIdENTS
I certi£y that:
1..I ,=nm £amiiiaP with the requiremenLs ¢or on-site sewers and wei].s as set
£orth by {he Municipality of Anchorage (MOA) and tine State oF Alaska.
2. I will ins{all tine system in accordance with all MOA codes arid reguIations~
al~d in compliance wi'Lb the design cPJ. tepia o¢ this per'mit.
3.' I wilI adhere to a].I MOA a~'~cl Gtat. e of Alaska requirements Cop the set back
distances Crom any existing welI wastewaten di. sposa] system of public
sewerage system on this or any adjacen~ or nearby lot.
4. I undenstar~d that this permi{ &s valid ¢o~ a maximum of 3 bedPooms arid
any enlargement will nequine an addi{ionaI 0epmit.
SIGNED
APPI_ICANT:
ISSUED BY
IF A LIFT STATION IS INSTALLED IN AN AREA COVERED BY MOA BUILDING CODES,
]FWEN (1) AN ELECTRICAL PERMIT AND INSPECTION NUST BE OBTAINED; (,'-2) AS-BUILTS
WILL NOT BE APF'ROVED WITNOUT AN ELECTRICAL INSPECTION REPORT; AND (3) TI4E
,~.LE[,TRICAL WORI< MUST BE DONE BY A LICENSED ELECTRI[,.[AI,I.
............................. .....
NUN X
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
825 L STREET, ANCHORAGE~ AK 99501
264-4720
PERMIT NO:
DATE ISSUED:
APPLICANT:
ADDRESS:
~]N---S ~ TE SE~ER ~-~- ~gEL. L. F"E~R~d I ]"
840627 k~
07/26/84
CONTACT PHONE:
BOB SOUTEC
% S,~o ENGINEERING
EAGLE RIVER, AK 99577
694-2979
I_EGAL DESCRIP: SUBDIVISION: NA.
SECTION: 5 TOWNSHIP: 15N
LO]' SIZE: 2.5A (SQ.FT. OR ACRES)
MAX BEDROOMS:
Listed below are the options available to you
system. Choose the option that best fits your
LOT: 21
RANGE:
BLOCK. NA.
~n designing your septic
site.
DEPTH TO ~IPE BOTTOM (FT.)
GRAVEL D~FTH (FT,,) '
TOTAL DEFTH (FT.) 7.0 - 8.0
GRAVEL LENGTH (FT.) 34 0 66.0
TANK SIZE (GALS) 1~000;0 ~'~ 1~000.0
SOIL RATING (SQ. FT. /BR) 125 125
TANK MUST HAVE AT LEAST TWO COMPARTMENTS
I certify that:
1. I am ¢amiliar with the requirements {or' on-site sewers and wet'ls as set
¢opth by the Municipality oF Anchopage (MOA) and the State o£ Alaska.
2. I will install the system in accordance with all MOA codes-and regulations~
and in compliance with the' design cpiteria oF this permit.
3.. I will adhere to all MOA and State o£ Alaska pequipements fop the sel back
distances Fpem any existing well~ wastewaten disposal system ep pwblic
sewerage system on this or any adjacent or n'earby lot.
4~ I understand, that this permit is valid Cop a maximum o£ 3 bedrooms and
any~enlargement will require an additional permit.
IF A LIFT STATION IS INSTALLED IN AN AREA COVERED BY MOA BUILDING CODES,
]'HEN (1) AN ELEGTRI~E~-~ERMIT AND INCPECTION MUST BE OBTAINED~ (2) ~S-BUILTS
WILL ~.OT BE A~PRO~E~.D W¢~:~O_UT AN ~//TRICAL INSPECTION REPORT;' AND (.~) THE
.......
MONIClPALITY OF ANCHORAGE
825 L, Street, Anchorage, Alaska 99501 264-4720
SOILS LO~ -- PERCOLATION TEST
2
8
11
13-
14-
15-
16-
17-
18-
19-
20-
SLOPE SITE PLAN
WAS ~ROUND WATER A JO S
ENCOUNTEREd? L
O
P
E
IF YES, AT WHAT
DEPTH?
Gross Net Depth to Net
Reading Date Time Time Water Drop
PERCOLATION RATE (minutes/inch)
COMMENTS
TEST RUN BETWEEN FT AND , FT
CEflT, FI ED I~n¢~~
72-008 (6/79)
MUNICIPALITY OF ANCHORAGE
DIVISION OF ENVIRONMENTAL MEALTH
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
APPLICATION FOR HEALTH AUTHORITY APPROVAL CERTIFICATE
1. General Information
Application Date
(a) Lega%.Description (include lot, block, subdivision, section, township, range)
Location (address or directions)
Applicants
(c) Applicant is (check one) Lending Institution
Buyer~; Other~-~ (explain);
(d) Lending Institution /OL~--;_~-
Telephone - Home Business
~--~ ; Owner/builder ~
Telephone
Address
(e) Real Estate Co. & Agent
Address
(f)
Telephone
~f't~he HAA to the following address:
~'& ~ £M8INE~RINM SR~ 19S~, ·
2. Type of Residence
Single-Family.~.
Number of Bedrooms
Multi-Family
Other (describe)
3. Water Supply
Individual Well ~ Community ~--~ Public ~--~
Note: If community well system, must have written confirmation from the State
Department of Environmental Conservation attesting to the legality and status.
4. Sewage Disposal,
Community~
Holding Tank~--~
Note: If community well system, must have written confirmation from the State
Department of Environmental Conservation attesting to the legality and status.
[Page 1 of 2]
Engineering Firm Providing Inspections~ Tests~ File. Search~ Data and Information
As certified by my seal affixed hereto and as of the validation date shown below, I
verify that my investigation of this Health Authority Approval ehows that the on-site
water supply and/or wastewater disposal system is safe, functional and adequate for
the number of bedrooms and type of structure indicated herein. I further verify that,
based on the information obtained from the Municipality of Anchorage files and from my
investigation and inspection, the on-site water supply and/or wast,water disposal
system is in compliance with all Municipal and State codes, ordinances, and regula-
tions in effect on the date of this inspection.
Name of Firm Telephone
DHEP Approval -~. ~'~.~ ~.~"~
Approved for/~Z~(~y bedrooms By~~ ~ Date ./
Approved ~ Disapproved __ Co~ition~
CAUTION
THE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
(DHEP) ISSUES HEALTH AUTHORITY APPROVAL CERTIFICATES BASED SOLELY UPON THE REPRESENT-
ATIONS GIVEN IN PARAGRAPH $ ABOVE BY AN INDEPENDENT PROFESSIONAL ENGINEER REGISTEEED
IN THE STATE OF ALASKA. THE DHEP DOES THIS AS A COURTESY TO PURCHASERS OF HOMES AND
THEIR LENDING INSTITUTIONS IN ORDER TO SATISFY CERTAIN FEDERAL AND STATE REQUIRE-
MENTS. EMPLOYEES OF DEEP DO NOT CONDUCT INSPECTIONS OR ANALYZE DATA BEFORE A
CERTIFICATE IS ISSUED. THE MUNICIPALITY OF ANCHORAGE IS NOT RESPONSIBLE FOR ERRORS
OR OMISSIONS IN THE PROFESSIONAL ENGINEER'S WORK.
(DHEP SEAL)
RR4/ej/Di8
[Page 2 of 2]
7-19-84
A®
MUNICIPALITY OF ANCHORAGE (McA)
HEALTH AUTHORITY APPROVAL (HAAi
CHECKLIST - FEBRUARY 1984
Well Log P~esent/ (Y~)
Total Depth ~ ~x , Cased to
Static Water Level 3~
Casing Height Above Grc~nd 30 *'
Electrical Wiring in Conduit (~
Separation Distances f~om Well:
MUNI¢ PA~, I'IY OF ANC:HOPAG~
DEPT. OF HEALTH &
ENVIRONMENTAL PROTECTIOIq
Legal Description: ~E~D ~-~
If A, B, ~ C, D.E.C.~ / ~/~Pr°~d(Y~~---/-~YieldF ~
~te ~leted /~
Pump Set At
Depth of G~outing
Sanitary Seal on Casing~/~)
Eep~ession A~ound Wellhead (Y~)
To Septic/N~ Tank on Lot
To Nearest Edge of Absorption Field on ~ot/~ '
To Nearest Public Hewer Line ~J /~ To Nearest Public Sewer
Cleanout/Manhole ~r ~ f~_ To Nearest Sewer Service Line on Lot
Water Sample Collected By~I~ C~4~/~4~'~//O~; Date
Wate~ Sample Test Results ~F~} ~[~ ~z~4~-~ To/'~?
C~tu~nts
; On Adjoining Lots /OO
; On Adjoining Lots
Be
Date Installed /O/~ Size /~_~ No. of C~%~a~tm~nts
Standpipes~ / ' . Ai~-ti~t ~ps~ Foun~tion Cloanout~)
~ession o~ Ta~ (~ ~te ~st P~d ' ~
P~ing~intena~ ~n~a~ ~~/File .(Q~ ; fJ ~ ~ ~--~/,
Holding Ta~ High-Wate~ ~a~ (Y~ ~ Holdi~ Ta~ ~t (Y~/~
~p~ation Distan~s ~ ~ptic~olding Ta~:
To Water-Supply ~11 /~ ~ To ~ilding F~ndation
To ~o~ty Li~ /d ~ To Dis~al Field
To ~ter ~ip~Se~vi~ Lir~ /~ ~ To S~e~, ~nd, ~e, ~ ~jor ~aina~
~ ~ ~ ~
Receipt #
Date Paid:
Amount:
[Page 1 of 2] 2-15-84
ABSORPTION FIE~LD DATA
Soils Rating in Absorption, Strata
Date Installed
Width of Field
Square Feet of Absorption A~ea
Dep=ession ove= Field QY~
Results of Last Adequacy Test
t~ of Last Ad~=quacy Test
Separation Distance from Absorption Field:
To Weter-Supply Well //~3 ~ To P=operty Line /~P
Type of System Design
Length of Field ~5~
Depth of Field
Gravel Bed Thickness
Standpipes P~esent
To Building ~ion
Lot ; On Adjoining Lots
To Water ~J~c. ln/Be~vice Line /O 7L To Cutbank( if present)
TO Stream/Pond/Lake/or Major D~aina~e Course
TO Driveway, Pa=king Area, c~ Vehicle Storage Area
ComTe nts /~3 o
~ ~ To Existing or Abandoned System cn
D. LIFT STATION
Date Installed
Size in Gallons
"Pump On" Level at
High Weter Alarm Level at
Tested fo=
Electrical Codes(Y/N)
"Pum~/Q~" Level at
Vent (Y/N)
Pumpxng Cycles during Adequacy Test~
Meets MOA
Con~aents
** Check Permitted Bedroom Rating Against HAA Request **
I (~rtify that I have checked, verified, or eonforr~d to all MOA HAA
on the date of this inspection.
KB]./d5/s
Date
MOA No.
[Page 2 of 2]
in effect
2-15-84