Loading...
HomeMy WebLinkAboutT15N R1W SEC 9 LT 70 T15N R1W SEC 9 LOT 70 #051-104-37 Permit Number:OSP251413 Tax Code Number:05110437000 Work Type:Septic Upgrade Effective Date: Design Engineer: Site Legal Address:T15N R1W SEC 9 LT 70 G:1358 Owner:BOLLARD RICHARD DALE & DONNA M Site Mailing Address:21928 BIRCHWOOD LOOP RD, Chugiak Lot Size in Sq Ft:108900 Total Bedrooms:3 This permit is for the construction of: Disposal Field Septic Tank Holding Tank Privy Non-Public Water Well Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Coodinate with On-Site staff regarding preferred method. 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing 11/20/2025 11/20/2026 FORGE ENGINEERING Expiration Date: þ þ ¨¨¨¨ Issued To: Issued By: Date: Date: 11/20/2025 11/20/2025 FORGE ENGINEERING Isatou B Njie MUNICIPALITY OF ANCHORAGE On-Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On-Site Wastewater Disposal System Permit November 17, 2025 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: T15N R1W SEC 9, Lot 70 - 21928 Birchwood Loop Rd Septic system design Dear On-Site Services Engineer: The owner of the above lot has a 3-bedroom home on the property, so we are submitting this permit application for the construction of a new septic system. The attached site plan identifies the location of the home and the proposed septic system. There are no conflicts with any other well or septic system on this lot or adjacent lots. The lot is generally flat, and the septic system is located in the flattest area. There are no slopes greater than 25% within 50 feet downslope of the site. Contours on the site plan show grade and flow direction. Stormwater drainage will not impact the system, and the trench will be constructed parallel to the slope. The well on this lot is shown. Wells on adjacent lots are not within viewing distance. The septic system will be a minimum of 100’ from all wells and surface water, and more than 5’ from the septic tank. Please refer to the attached test hole log, plan, and profile pages for the septic design. Following this design will ensure no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251413, Isatou Njie, 11/20/25 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 1"=50' CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND MT TH#1 T15N R1W SECTION 9, LOT 70 FEET 0 50 100 FS 3-BDRM HOME SEPTIC PLAN 10/30/25 CO 50 ' R O A D W A Y & U T I L I T Y R E S E R V A T I O N EXISTING 1000-G TANK TO BE DECOMMISSIONED EXISTING LOG SEEPAGE PIT TO BE DECOMMISSIONED 50' ROADWAY & UTILITY RESERVATION 2CO MT COMT CO MT CO 2 @ 45' x 5' LONG x 0.5' EFFECTIVE DEPTH NEW 1000-G TANK FCO TO BE FOUND AT TIME OF INSTALL OR 2CO TO BE INSTALLED BEFORE TANK EXISTING WELL 235 240 235 230 230 230 235 2CO LOT 69B WELL NOT IN VIEW PORT LOT 69A WELL 100' RADIUS LOT 87 WELL NOT IN VIEW PORT LOT 71 WELL NOT IN VIEW PORT 10 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251413, Isatou Njie, 11/20/25 T12N R1W SECTION 9, LOT 70 TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER DESIGN FACTORS:SYSTEM REQUIREMENTS: 450 GPD PEAK FLOW PERK RATE: <1 MIN/IN APPLICATION RATE: 1.0 GPD/SF 5' WIDE TRENCH SYSTEM 1000-GAL SEPTIC TANK BOTTOM OF TRENCH: 4.0' BELOW GRADE FLOW LINE ELEVATION: 3.5' BELOW GRADE 450 GPD / 1.0 GPD/SF / 5.0' WIDE * 1.0 RED FACTOR [0.5' DEEP] = 90 LF TRENCH REQUIRED (90 LF SPECIFIED) 10/30/25 6" 5' 2' 6" 3' 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK GEOTEXTILE FABRIC PROVIDE ADDITIONAL FILL TO ACCOUNT FOR SETTLEMENT MOA APPROVED SAND Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251413, Isatou Njie, 11/20/25 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 DEPTH (feet) TEST HOLE 1 DATE READING NET TIME (minutes) DEPTH to WATER NET DROP PERCOLATION RATE: (MIN/INCH) (inches)(inches) DATE OF MONITORING DEPTH TO WATER AFTER MONITORING <1 10/16/25 1 2 3 4 5 6 GM (GRAVEL WITH SOME SAND) Professional Engineers Stamp: T15N R1W SECTION 9, LOT 70 10/16/25 051-104-37 RICHARD BOLLARD --- OB --- Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER PERC TEST LOCATION TECHNICIAN: JARED E --- NONE 10/23/25 COMMENTS: SITE PLAN --- USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED EXCEPT WHERE NOTED. 10/30/25 MOISTURE NOTED AT TIME OF DIGGING?NONE A S FAS T A S IT W A S P O U R E D Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251413, Isatou Njie, 11/20/25 GAAB-HD- I G; ~TER ANCHORAGE AREA BORO! DEPARTMENT OF ENVIRONMENTAL QUALrlY 3500 TUDOR ROAD ANCHORAGE, ALASKA 99507 279-8686 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM LOCATION SEPTIC TANK: MAILING ~¢. ADDRESS PHONE. ,LEGAL DESCRIPTION Z'/ DISTANCE FROM WELl ¢7 LIQUID CAPACITY____-/-C7'' ~",)C~ .MATERIAL GALLONS. INSIDE LENGTH. NUMBER OF / COMPARTMENTS INSIDE WIDTH, DEPTH SEEPAGE SYSTEM: SEEPAGE PIT: NUMBER OF PITS. // __OUTSIDE DIAMETER LINING MATERIAL~'(~' ¢~/. ,~¢~'(~./~)' *' '~ NEAREST LOT LINE -~,~-~! ¢ '~* /(~ .... OR WIDTH /~" , LENGTH /~ , DEPTH __ DISTANCE FROM WELL ///~ ' , BUILDING FOUNDATION TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) ~'~: ~-'~C~ SQ. FT. TILE DRAIN FIELD: DISTANCE FROM WELL_ NUMBER OF LINES__ __x/ ABSORPTION A~/_ ~ .NEAREST LOT LINE DISTANCE BETWEEN LINES_~"'-~ TRENCH WIDTH SQ. FT. LENGTH OF EACH LINE~'"'"'"'~ DEPTH: fOP OF TILE TO FINISH GRADE TOTAL LENGTH OF LINES DEPIH OF FILTER MATERIAL BENEATH TILE IN. ABOVE TILE WELL: TYP E'~'¢', J J',~ b DEPTH c'~' '~~' ,__ NEAREST SEPTIC LOT UNE ., SEWER LINE TANK DISTANCE FROM - ' WATER ,BUILDING FOUNDATION. ~'~'~ _SAMPLE ~OO~,~6 , NEAREST C~ '~! SEEPAGE //~,~ / ,. OTHER , SYSTEM , CESSPOOL , SOURCES__ DISTANCES: DIAGRAM OF SYSTEM APPROVED DA, E /fy -//7/ GAAB-HD-2 GREATEI~ ANCHORAGE AREA' HEALTH DEPARTMENT 327 Ea~le St. Anchorage, Alaska 99501 ~ROUGH 279-2511 Case No. SEWAGE DISPOSAL SYSTEM - APPLICATION & PERMIT R ES,OENCE A D DH ESS _~ ~,~ LO CAT,ON OF,NSTAL'AT'ON ~ LEOALDESCRIPTION ~ 7~' ~ / APPLICATION TO INSTALL: SEPTIC TANK ~, ,SEEPAG~PIT~,DRAIN FIELD ,OTHER FINANCED THROUGH TO BE INSTALLED BY PERCOLATION TEST RESULTS /~¢'~'~' .ANTIOIPATEB BAT 60M"LETION BELOW TO BE FILLED OUT BY HEALTH DEPARTMENT . THIS IS TO SERVE AS z~,.,~¢ "~"-"' PERMIT TO INSTALL A ~-ir- ~ ~- - : ¢-'~/.¢.~¢.~"~ AS DESCRIBED BELOW, SIZE OF UNIT TO BE SERVED ~.~ ': . SEPTIC TANK SIZE /¢'~¢ ~;'~' TYPE/¢?~'~/ SEEPAGE AREA TYPE DIAGRAM OF SYSTEM DISTANCES: I certify that I am familiar with the requirements of Greater Anchorage Area Borough Ordinance No, 28-68 and that the above described system is in accordance with said code. APPLICANTS SIGNATURE