Permit Number:OSP251413
Tax Code Number:05110437000
Work Type:Septic Upgrade
Effective Date:
Design Engineer:
Site Legal Address:T15N R1W SEC 9 LT 70 G:1358
Owner:BOLLARD RICHARD DALE & DONNA M
Site Mailing Address:21928 BIRCHWOOD LOOP RD, Chugiak
Lot Size in Sq Ft:108900
Total Bedrooms:3
This permit is for the construction of:
Disposal Field Septic Tank Holding Tank Privy
Non-Public
Water Well Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Coodinate with On-Site staff regarding preferred method.
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
11/20/2025
11/20/2026
FORGE ENGINEERING
Expiration Date:
þ þ ¨¨¨¨
Issued To:
Issued By:
Date:
Date:
11/20/2025
11/20/2025
FORGE ENGINEERING
Isatou B Njie
MUNICIPALITY OF ANCHORAGE
On-Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On-Site Wastewater Disposal System Permit
November 17, 2025
MOA Development Services, On-Site Water & Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: T15N R1W SEC 9, Lot 70 - 21928 Birchwood Loop Rd
Septic system design
Dear On-Site Services Engineer:
The owner of the above lot has a 3-bedroom home on the property, so we are submitting this
permit application for the construction of a new septic system. The attached site plan identifies
the location of the home and the proposed septic system. There are no conflicts with any other
well or septic system on this lot or adjacent lots.
The lot is generally flat, and the septic system is located in the flattest area. There are no slopes
greater than 25% within 50 feet downslope of the site. Contours on the site plan show grade and
flow direction. Stormwater drainage will not impact the system, and the trench will be
constructed parallel to the slope.
The well on this lot is shown. Wells on adjacent lots are not within viewing distance. The septic
system will be a minimum of 100’ from all wells and surface water, and more than 5’ from the
septic tank. Please refer to the attached test hole log, plan, and profile pages for the septic design.
Following this design will ensure no adverse impacts to adjacent properties.
Sincerely,
Benjamin Schiller, PE
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251413, Isatou Njie, 11/20/25
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
1"=50'
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
MT
TH#1
T15N R1W SECTION 9, LOT 70
FEET
0 50 100
FS
3-BDRM HOME
SEPTIC PLAN
10/30/25
CO
50
'
R
O
A
D
W
A
Y
&
U
T
I
L
I
T
Y
R
E
S
E
R
V
A
T
I
O
N
EXISTING 1000-G TANK TO BE
DECOMMISSIONED
EXISTING LOG SEEPAGE PIT TO
BE DECOMMISSIONED
50' ROADWAY & UTILITY RESERVATION
2CO
MT
COMT
CO
MT
CO
2 @ 45' x 5' LONG x 0.5'
EFFECTIVE DEPTH
NEW 1000-G TANK
FCO TO BE FOUND AT
TIME OF INSTALL OR
2CO TO BE INSTALLED
BEFORE TANK
EXISTING WELL
235
240
235
230
230
230
235
2CO
LOT 69B WELL NOT IN VIEW PORT
LOT 69A WELL 100' RADIUS
LOT 87 WELL NOT IN VIEW PORT
LOT 71 WELL NOT IN VIEW PORT
10
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251413, Isatou Njie, 11/20/25
T12N R1W SECTION 9, LOT 70
TYPICAL TRENCH SECTION
(NO SCALE)
NOTES:
1. GRADE AREA OVER TRENCH TO DRAIN AWAY
2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
DESIGN FACTORS:SYSTEM REQUIREMENTS:
450 GPD PEAK FLOW
PERK RATE: <1 MIN/IN
APPLICATION RATE: 1.0 GPD/SF
5' WIDE TRENCH SYSTEM
1000-GAL SEPTIC TANK
BOTTOM OF TRENCH: 4.0' BELOW GRADE
FLOW LINE ELEVATION: 3.5' BELOW GRADE
450 GPD / 1.0 GPD/SF / 5.0' WIDE * 1.0 RED FACTOR [0.5' DEEP] = 90 LF TRENCH REQUIRED
(90 LF SPECIFIED)
10/30/25
6"
5'
2'
6"
3'
4" PERFORATED PVC
(HOLES DOWN)
DRAINFIELD ROCK
GEOTEXTILE FABRIC
PROVIDE ADDITIONAL FILL TO
ACCOUNT FOR SETTLEMENT
MOA APPROVED SAND
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251413, Isatou Njie, 11/20/25
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE: PARCEL ID#:
SOILS LOG AND PERCOLATION TEST
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
DEPTH
(feet)
TEST HOLE 1
DATE READING NET TIME
(minutes)
DEPTH to
WATER NET DROP
PERCOLATION RATE: (MIN/INCH)
(inches)(inches)
DATE OF MONITORING
DEPTH TO WATER AFTER MONITORING
<1
10/16/25 1
2
3
4
5
6 GM (GRAVEL WITH SOME SAND)
Professional Engineers Stamp:
T15N R1W SECTION 9, LOT 70
10/16/25 051-104-37
RICHARD BOLLARD
---
OB
---
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
PERC TEST LOCATION
TECHNICIAN: JARED E
---
NONE
10/23/25
COMMENTS:
SITE PLAN
---
USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED EXCEPT WHERE NOTED.
10/30/25
MOISTURE NOTED AT TIME OF DIGGING?NONE
A S FAS
T
A
S
IT W
A
S
P
O
U
R
E
D
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251413, Isatou Njie, 11/20/25
GAAB-HD- I
G; ~TER ANCHORAGE AREA BORO!
DEPARTMENT OF ENVIRONMENTAL QUALrlY
3500 TUDOR ROAD ANCHORAGE, ALASKA 99507 279-8686
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
LOCATION
SEPTIC TANK:
MAILING ~¢.
ADDRESS PHONE.
,LEGAL DESCRIPTION Z'/
DISTANCE FROM WELl ¢7
LIQUID CAPACITY____-/-C7'' ~",)C~
.MATERIAL
GALLONS. INSIDE LENGTH.
NUMBER OF /
COMPARTMENTS
INSIDE WIDTH, DEPTH
SEEPAGE SYSTEM: SEEPAGE PIT:
NUMBER OF PITS. // __OUTSIDE DIAMETER
LINING MATERIAL~'(~' ¢~/. ,~¢~'(~./~)' *' '~
NEAREST LOT LINE -~,~-~! ¢ '~* /(~
.... OR WIDTH /~" , LENGTH /~ , DEPTH
__ DISTANCE FROM WELL ///~ ' , BUILDING FOUNDATION
TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) ~'~: ~-'~C~ SQ. FT.
TILE DRAIN FIELD:
DISTANCE FROM WELL_
NUMBER OF LINES__ __x/
ABSORPTION A~/_
~ .NEAREST LOT LINE
DISTANCE BETWEEN LINES_~"'-~ TRENCH WIDTH
SQ. FT. LENGTH OF EACH LINE~'"'"'"'~
DEPTH: fOP OF TILE TO FINISH GRADE
TOTAL LENGTH
OF LINES
DEPIH OF FILTER MATERIAL BENEATH TILE IN. ABOVE TILE
WELL: TYP E'~'¢', J J',~ b DEPTH c'~' '~~'
,__ NEAREST SEPTIC
LOT UNE ., SEWER LINE TANK
DISTANCE FROM - ' WATER
,BUILDING FOUNDATION. ~'~'~ _SAMPLE ~OO~,~6 , NEAREST
C~ '~! SEEPAGE //~,~ / ,. OTHER
, SYSTEM , CESSPOOL , SOURCES__
DISTANCES:
DIAGRAM OF SYSTEM
APPROVED
DA, E /fy -//7/
GAAB-HD-2
GREATEI~ ANCHORAGE AREA'
HEALTH DEPARTMENT
327 Ea~le St. Anchorage, Alaska 99501
~ROUGH
279-2511
Case No.
SEWAGE DISPOSAL SYSTEM - APPLICATION & PERMIT
R ES,OENCE A D DH ESS _~ ~,~ LO CAT,ON OF,NSTAL'AT'ON ~
LEOALDESCRIPTION ~ 7~' ~ /
APPLICATION TO INSTALL: SEPTIC TANK ~, ,SEEPAG~PIT~,DRAIN FIELD ,OTHER
FINANCED THROUGH TO BE INSTALLED BY
PERCOLATION TEST RESULTS /~¢'~'~' .ANTIOIPATEB BAT 60M"LETION
BELOW TO BE FILLED OUT BY HEALTH DEPARTMENT
.
THIS IS TO SERVE AS z~,.,~¢ "~"-"' PERMIT TO INSTALL A ~-ir- ~ ~- - :
¢-'~/.¢.~¢.~"~ AS DESCRIBED BELOW, SIZE OF UNIT TO BE SERVED ~.~
': . SEPTIC TANK SIZE /¢'~¢ ~;'~' TYPE/¢?~'~/ SEEPAGE AREA TYPE
DIAGRAM OF SYSTEM
DISTANCES:
I certify that I am familiar with the requirements of Greater Anchorage Area Borough Ordinance No, 28-68 and that the
above described system is in accordance with said code.
APPLICANTS SIGNATURE