HomeMy WebLinkAboutT15N R1W SEC 9 LT 123A
GREA-"~R ANCHORAGE AREA BORr
Department of Environment QUality
3500 Tudor Road
Anchorage, Alaska ggS07
~GH
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
SEPTIC TANK:
DISTANCE ~
FROM WELL/'¢'~g2
INSIDE LENGTH
MANUFACTURER .~'~y..~.z~'¢',~ MATERIAL
NUMBER OF
COMPARTMENTS
INSIDE WIDTH
LIQUID DEPTH
LIQUID CAPACITY/,~/)~ GALLONS.
TILE DRAIN FIELD:
DISTANCE FROM WELL /'~'~ '/' FOUNDATION ~ ~ '¢ OF LINES
NEAREST LOT LINE '~' · TOTAL LENGTH
NUMBER OF LINES ~/ DISTANCE BETWEEN LINES ~'~ ,F
TRENCH WIDTH :2~ ~N. TOTAL EFfECTiVE
ABSORPTION AREA SQ. FT, LENGTH OF EACH LINE I~/~F ~/''~-' ~ /1~'" 'ZO ~'
DEPTH: TOP OF TILE TO FINISH GRADE_ ~,t* DEPTH OF FILTER ! ~./
MATERIAL BENEATH TILE ~ IN. ABOVE TILE IN.
WELL:
TYPE
BUILDING
FOUNDATION ~.t.~ ~.,
CESSPOOL
APPROVED
CONSTRUCTION
NEAREST ~ ~'
LOT LINE ,
OTHER SOURCES
DISAPPROVED
NEAREST SEPTIC ~
sEWeR L,NE lU/4 , TAN
REMARKS
DEPTH ~'<:~') DISTANCE FROM:
SEEPAGE
SYSTEM
DISTANCES:
INSTALLED BY:
SEWER LINE DEPTH:
PIPE MATERIAL:
LOT SLOPE:
REMARKS:
DIAGRAM Of SYSTEM
G.A.A.B.
Form PW~027
greATer ANCHOrAgE AREA borOUgh
DEPARTMENT OF ENVIRONMENTAL QUALITY
SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT
PERMit NO,
INSTALLAT]ON LOCATION
INSTALLATION OF: SEPTI~ TANK ~ SEEPAge PIT ~
FINANCED THROUGH TO BE INSTALLED BY __
FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY Will BE SUBJECT TO PROSECUTION.
__., DRAIN Field
TO NEAREST LOT LINE.
WELL TO SEPTIC TANK --?
WATER MAIN TO SEPTIC TANK
, SEEPAGE Pit //~ /
ALSO CONSIDER AREA WELLS.
, SEePAge P'T /0 /
DRAIN Field /~ I
SEPTIC TANK, __/ /~/~1___,~ - SEEPAGE PIT //~/)~) ~ , DRAIN FIELD
/
TO RIVER, LAKE, STREAM.
CAST iRON iNTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF
EXCAVATION 5 FEET INTO UNDISTURBED SOIL.
4 INCH DIAmeter CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE Pit
FVrTED WFT~{ Al RTIGHT ~EMOVABLE CAPS.
GRAVEL BACKFILL
CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION.
[ CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 2~-68 AND THAT THE ABOVE
DESCRIBED SYSTEM IS IN ACCORDANCE With SAID CODE.
O ~ E GEO'i-,CliNICAL 6t DEVELL2MENT CO.
Box 90, Davis St,, Eagle River, Alaska 99577
694-2774 or 688-2280
Russell Oyster
694-2774
Soils ~t Foundations
Performed for:
SO[L LOG
Name: '-.~/4 /~/E/7T, z///d
Matltng Address: ~, 0 ./~c;x .2o ~ ~
Legal Description:
De0th (feet)
/~/g r ~'Z~ ~o~-/z3 ,5, ~/,
S~ll {haractertstlcs
Earl Ellis
688-2280
Land Development
..Tel. No. ~ F r-Z~TM
0
1 ,.. M/Z-
¸2,
G~ound Water Encountered: Yes ~ No
P~oposed Installation: Seepage Pit
Co.~ents:
If yes, what depth
Drain Fie~d
Date: