HomeMy WebLinkAboutCLEARY LT 1i5N cw�� taw% NEyy y Lot MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP251205 Effective Date: Work Type: Septic Upgrade Expiration Date: Tax Code Number: 05110276000 Site Legal Address: CLEARY LT 1 G:1359 Site Mailing Address: 22813 DALLON CT, Chugiak Owner: HAEUSSLER KATE S & PETER JOHN Lot Size in Sq Ft Design Engineer: FIRST WATER CONSULTING Total Bedrooms: This permit is for the construction of: 6/27/2025 6/27/2026 55775 Z Disposal Field Z Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: � Issued By: 3 Date:' s Date: ON -SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 051-102-76 Property owner(s) Kate & Peter Haeussler Mailing address 22813 Dallon CT, Chugiak, AK 99567 Site address 22813 Dallon CT, Chugiak, AK 99567 Legal description CLEARY LT 1 Number of Bedrooms 3 Engineering Firm First Water Consulting Building Permit Number Day phone Not Applicable R APPLICATION IS FOR: APPLICATION IS AN: (N all that apply) Absorption Field F&I Initial ❑ Septic Tank Upgrade F&I Holding Tank ❑ Renewal ❑ Privy ❑ Well ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: Permit/Rush Fees: �rqs_o Waiver Fees: Date of Payment: 6ha Date of Payment: MP Permit No. Waiver No. Q �Li Qo� 13030 Sues Way, Anchorage, AK 99516 907-350-9566 / firstwaterAK@gmail.com ! !! June 26, 2025 Municipalities of Anchorage On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 RE: SEPTIC SYSTEM UPGRADE PERMIT LEGAL: CLEARY LOT 1 The property owner has requested we obtain a permit to upgrade the failed & undocumented septic system of the above referenced lot. We propose to install one deep trench and a 1500- gallon deep-burial HDPE STEP tank to serve the 3 -bedroom residence. The design is based on the recent test hole conducted on May 22, 2025. No groundwater was observed at test hole excavation or monitoring. The slopes are flat at the proposed upgrade location. The lot and area are served by private water. The design will not impact any of the neighboring properties. Please contact us if you have any questions. Sincerely, Curtis Huffman, P.E. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251205, Curtis Townsend, 06/27/25 9 First Water . CONSULTING 13030 Sues Way, Anchorage, AK 99516 907-350-9566 / firstwaterAK@gmail.com September 4, 2025 Municipalities of Anchorage On -Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 RE: OSP251205 SEPTIC SYSTEM UPGRADE PERMIT LEGAL: CLEARY LOT 1 The undocumented septic system was located today and therefore in lieu of one long pressurized trench the design was amended to install 2 trenches per the attached. The lot and area are served by private water. The design will not impact any of the neighboring properties. Please contact us if you have any questions. Sincerely, Curtis Huffman, P.E. FFS1 "� �t� IE. I tIEWhI ER 1'P 1%'. IEk4N1110 DESIGN DETAILS: c c It -I INSTALL NEW 1500-GAL DEEP -BURIAL HDPE STEP TANK. INSTALL TWO 32'L x 2'W x 6'ED TRENCHES - 8' OG. MAINTAIN 10'+ FROM FOUNDATION, 200' TO PUBLIC WELLS, 100' TO PRIVATE WELLS & 100, TO SURFACE WATER, 5' TO FIELD & DECK SUPPORTS & ALL OTHER REQUIRED SEPARATIONS WITH 4' OF COVER OR INSULATION. OVER TANK & 3'+ COVER OVER FIELD OR 2'+ OF FIELD COVER W/ INSULATION. INSTALL PER AMC 15.65, 15.55, & MASS ... TANK BEDDING, SEPARATIONS, MATERIALS,...VERIFY & STAKE ANY REQUIRED SEPARATIONS PRIOR TO CONSTRUCTION v17� o LOG HOME • \ \ r \ 9 r r o r o �, 8 o 21. 3.5 •• z 69.5' \ r z v.1 � GREEN w /'� o M. \ r \ r r r N O . H pUSE o // \ 35.3 i r r Go ■ oom J R r l r / FCo U N 12.7 S r I r INSTALL i C r I r FCO / r r DECOMMISSION J EXISTING SEPTIC TANK / I r r & INSTALL NEW APPROX I 100' WELL ' ' 1500-GAL p/ FIAT HOPE STEP TANK. RADIUS r I r r r ASSUME UNDOC STAKE 100' WELL RADIUS / r ( r FIELD AREA DCO PRIOR TO CONSTRUCTION / r ( r J r I r MAR TAIN 12'+ TO ANY MH c° --- r r SEP & C FIELD & REMOVE REPLACE WITH MN FIAT NO WELLS WITHIN I SITU NEEEDBE Lo 125" PVC 100' OF PROPOSED ; —12'+ I SEPTIC TANK OR , i EXCAVATED , APPRCX`- MT I MT c°J N TH25-1 / EXISTING FIELDS. r I r LEACH LD FLAT ' MT FLAT r r /J FLAT r I r MT / TWO TRENCHES / ---oU--- RG IlSION 0 _ _ - 32'l x 2'W x WED- 8'OC�°- - - ---- --- I - - -- - - - - I FLATT&E ESM T., / FAT STAKE PROPERTY LINES AND EASEMENTS PRIOR TO CONSTRUCTION DALLO N 30' - - - - W W FLAT �co APPROX V 100' WELL / n ) O� r RADIUS SUPPORT SERVICES: CLEARY LT1 ! OF PREPARED FOR: EUSSLER* �FH ��`Q� , 22813 DALLON CT � � � � �� CHUGIAK, AK 99567 FIRST WATER CONSULTING DATE: 09/04/2025 /` rtis Huffman SURVEY. TJB , CE 128991 13030 SUES WAY DRAWN: FWCS , 09/04/202V W ANCHORAGE, AK 99516 SCALE: 1" = 30' 907-350-9566 FirstWaterAK@gmail.COM PAGE: 2 OF 2 ��``°�� DESIGN CALCS: 3BR X 150 GPD = 450 450 GPD/0.6 GPD/SF = 750 SF SAS 750 SF / (2 X 6' ED) = 63 FT. TRENCH USE 2 TRENCHES - 32'(L) X 2'(W) X 6'(ED) TOTAL MAX DEPTH FROM EXISTING GRADE: -8' 64 LF 1.25" PVC W/ ij" HOLES ® 2.1' SPACING 15 HOLES PER TRENCH LATERAL (30 TOTAL). / II i I \ I I I 1 I ,ar WILLRADIUS I I II II II II i I i i i N 1 \\ I 1 O O Fw_ 7 �o Q \ i \ 0 J2 �,1 Q \ \9 o NO SLOPES >25% WITHIN 50'OF PROPOSED FIELD. STAKE PROPERTY LINES, WELL RADII, ESMTS, OR OTHER SEPARATIONS... PRIOR TO CONST. z28CLEAR n li� SHED SUBDI VlSlO ONE STORY LOG HOME O 69.5' \ z GREEN \ I HOUSE i 1 I I I 127 i I I i I I \17 t� I I I i III i I FOD AREA I I , Mlr+TOw iE1D tVM ' 1 I I ! aEs,wcc w,x 9l.T�uV13 i I I i !® BE I 7i I E ' _� LEACHF F i I I M - - —IIU MT LOT I (PLAT 98-82) 5� N Room h I ,.?S PVC nT I WT MT tl M', YT O/ 3n MTM c W, T&E Eswmr/ MT i 1 \i 1 1 1 I ROK , NEL i RA I RA oEls IU 1 I � 1 1 Iz 1 I M 'N 1 ' LIJ ' I� ' u7 h Qi CN I U71 ao I W 1 pq o N �, 0 0 1— cs � Z 0010 o i i Z 1 � � 1 1 1 l0 Ir 1 �o� z i IPw i IZW I i IOU IJ1— i IOU J I I 1. W I 1 I 1 1 ..�D-..--...--...--.. ' OBERG `r- P�°"ro'" DALLON Nr-- - - - - -- UBDI VISION ; 3Uj v .iw LOT A-2 RADIUS N-j(r)Q,-+---------------- (PLAT 2012 92) w IL + TRACT A CLEARY LT1 SUPPORT�SERVICES: +\\ low OF F PREPARED FOR:PETER & KATE HA �4� , 22813 DALLON CT EUSSLER CQ ffg H* CHUGIAK, AK 99567 FIRST WATER CONSULTING DATE: 09/04/2025 tls Huffman / SURVEY. TJB , CE 128991 13030 SUES WAY DRAWN: FWCS t 09/04/25� ANCHORAGE, AK 99516 SCALE: 1" = 50' 907-350-9566 FirstWaterAK4gmail.com PAGE: 1 of 2 \�\�.�►�"� 13030 Sues Way - Anchorage, Alaska 99516 Tel. 907-350-9566 firstwaterAK@gmail.com SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: CLEARY LOT 1 PERFORMED BY: FWCS / FWC - I CURTIS HUFFMAN CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE & MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 06/04/2025 DEPTH FEET OG SOILS 1 ORG/OL 2 3 4 5 6 7 8 GM 9 10 11 12 13 14 15 16 17 BOH 18 19 20 Reading Date Gross Time Net Time Depth to Water Net Drop 06/03/25 30 min 6” 1 13/16” 30 min 6” 1 12/16” 30 min 6” 1 13/16” PERCOLATION RATE 17 (MIN / INCH) TEST RUN BEWTWEEN 4 & 5 FT PERC HOLE DIAMETER 6” PRE-SOAKED PRIOR TO TEST & ALL READINGS TO THE 1/16TH. GROUND WATER ENCOUNTERED: NO IF YES, AT WHAT DEPTH: NA DEPTH TO WATER AT MONITORING: DRY DATE: 5/30/2025 TESTHOLE # 25-1 DATE PERFORMED: 5/22/25 SEE SITE PLAN FOR SLOPE & LOCATION COMMENTS: VERIFY GROUNDWATER MT AT TIME OF CONSTRUCTION PERFORMED FOR: KATE & PETER HAEUSSLER 06/04/25 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251205, Curtis Townsend, 06/27/25 � m c > 6 n (. �'O� v o r _ o Z w p�*W >o ■(onm �' % �: cr Ci > r .0D 1 0 0o r a0 _0 > N v0 N ■��� • �`♦ <� to J c0 � _U • I N rn gZ o ELSIE _ `' PLACE NORTH ;o mz CD o pa� v--T �.wo n» _ rt-.d .�-1'• W T.` n «. n o o' - w m o o a.0 (mi m = a O a O O -•" Ul "-nm�we�n" C � �o3_�ww N_ 7_ m s OD r n a. -• •. a rt'w rt� o o -. ¢ m 0 0 0 0 a < — < m m U) Q0 fl o„ 0 8 (D fD 7 c CD 1 � A m c r -O (D 7 m Vl < •.c •.. � �o•f I}, �,ri i .� o o - O .1+ •- � w .. -. � x .c � a. -• a � rt � rt .G 7a -•W ¢n w �oo� o •w¢ - c' m rty O U) S •G O O m m D-� �N.n. O n c¢- O ® .w.�¢.o. d a N .. M (7 f/1 < rt I Z 1 i ' 00•�•ac sm _m my¢ o -0Z0m m Z rtO. d n O � -..••..2♦ O .«n < m O : ti m� � O 0MT m w. �rt — J(D W`in, Z � o oc m 0 N CL IjIf � ` �. D m n m •a3 s c O •� Z W :.:5 . r�, T rtha w= on. . a "'.a• _ , ••' m a aA N owao'w— ovwn o 3CL m0 L v) t o (D (D 7 -• fn U) (D 1I µHm c Lt w 6n o o rt p S Z m 0 o m 0 c EID 2�mwy�s0 rt0 Z , L O o9+ rt o w o m ¢ m (b rLIE •, , -• N m o 0 m w m 7 rt c , » 7 m n -• o o _- = a m irV I� 0 n rt omo¢ N -� V0 y w m 9'10 m O y � om �n O w r womw .•c �m mm�m+ OlG o_m rf x x x II OD '` x x x N NQ o >' Is,� ,� � o TI Zm z -0 � �n -0 � �n I - g D -Di c "�� -V --1 m, (n c) N m m � o cn WzEq TI pC -n C r m m (.n �p m� �p �p to m r mr^ n D(l1 z z 'n m J C) o o p ;o� 0 r C7 OD p p z C.i n Y o I�� O0 m C m n OWE O m wm oA I/V C ND N D> D r- r- r'I Z Eln �� m 0 W %IAv� m mD �- n () `- Z C� � - - - - - _ - - - - - m D p -------- - - - - - -_ - --- (NO °03'16" E --------------- 305.00) - - - - - - - - - - - - - - - - - - - - NO°00'30"W r 305.26' n 'moo ,F - rn Fn o ^, ram rDZ tye rn� ,m r ; m 'mz �r \0&, r 95.7' !r � t:.f' �,,-4, wig ' Y' rn �rn � re.SN r I•x N 1, rh LW 1, u a 0 "- �.,.. •coA W �1 • - - - - - - - - - - - - •- - - - - - - - - -- -10' TELECOMMUNICATION & ELECTRICAL EASEMENT 1 _ .NO°18'17"W 305.13' 10' TELECOMMUNICATION (NO ° 1 B'17'W 305.01) & ELECTRICAL EASEMENT BASIS, OF BEARING / 7- IL AT 1\ 1, PERMIT NO. [~EPARTMENT nF HEALTH AND ENVIRONMENTAL PROTECTION 825 ~ STREET, ANCHORAGE., 279-251:J. ( 7708D ) 688-25i6 AF'PLICIZlNT E:,A.LLON_.OBERG P 0 BI..I.,,. ;~7¢i I_:HU..iIHK LOCA'I" I ON 08ER,O RD, , LEGAL W::L,'21NW'I,'~NE:I.../~NEit.,"4~sglril-.-,f'~Ri'LW LQT SIZE 54450 SQ..ARE FEET MINIMUM DISTANCE BETWEEN A WELl_ AND :1.00 FEET FOR R PRIVATE WELL OR 200 FEET FOR A PUBLIC WELL. WELL LOGS ARE RED. UIRED AND MUST BE R. ETURNED TO THE DEPARTMENT WI]"HIN ".~0 DR"r'S OF ]'HE WEL. L CQMPLE'T'ION. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE A',/FIILABI_E TO INSURE PR[]PER I NS'T'AI_LA'[ I ON. F-"' E;R I'"1 I 3F "¢RLI D F,]mR IZ)I'-.IEE ".r" b'] FIF-: F'F~:,]:,I"'J ][ I CERTIF'¥ THAT ±: I AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS RS SET FORTH 8~¢ THE MUNICIP8LIT9 OF ANCHORAGE. 2: I WILL INSTALL THE S'¢STEM IN ACCORDRNCE WITH THE CODES. RECE VEO (gertifiei Drilling by A & L DRILLING COMPANY BOX 97, EAGLE RIVER, ALASKA 99577 · TELEPHONE 694-2588 OWNER OF LAND ~/~],LLoe',d Q~/-,ef.~ DEPTH OF WELL ADDRESS -~Z c~ STATIC LEVEL OF WATER FT. LEGALDESCRiPTION_C_~,~ ~ c~r'ol~z~I:- /~2d~'~. t~tfdq_~'~t3 DRAW DOWN FT. DATE-Started---- $//~a/7 7 Ended ~/~ $-/77 GALS. PER HR PERMIT NUMBER __ ~l 70~ci KIND OF CASING ~ d~ ~ Or9' KIND OF FORMATION: From ~) Ft. to ~ Ft. From_ ~ ~d Ft. to Ft. From q ~i' Ft. to /ff'~F Ft. From /';~!' Ft. to / ~-t Ft. From ;'~5" Ft. to From [cID Ft. to From Z'(~zj Ft. to ~)r; From __.Ft. to Ft. From__.Ft. to Ft. From__.Ft. to.__Ft. From__Ft. to Ft, From__.Ft. to Ft. From__.Ft. to Ft. From__.Ft. to__ _Ft. From Ft. to Ft. From Ft. to Ft. From__Ft. to FI From _ _~Ft. to From_ Ft. to From From__ From From_ From From From From Ft. Ft. Ft. Ft Ft~ Ft Ft. to Ft. Ft. to Ft. Ft. to Ft. Ft. to__Ft. .Ft. to Ft, Ft. to__Ft, Ft. to__Ft, Ft. to.__ Ft Ft. to__ Ft. to Ft. to Ft. Ft ..... Ft. MISCL. INFORMATION: DRILLER'S NAME