HomeMy WebLinkAboutT15N R1W SEC 30 LT 84Onsite File 15N RIW Sec 30 0 M16121A :: 299EI "11% AVEC Septic System  I MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT [] UPGRADE LEGAL DESCRIPTION NO. OF BEDROOMS -- ~ 9 ~ Abs°rpti°n area ' Dwe,ling ' z Manufacturer 6~ Material No. of compartmentsx ~ DISTANCE TO: /7~ ~ Trench ~h /5~ No. of lines Len th f ach li~ Total ]en th of lines Distance between lines Top of tile to finish grade ~ ~ /¢ Material beneath tile ~ ~ inches Length Width Depth PERMIT NO, ~ DISTANCE TO: OTHER PERHIT NO~ APPLICBNT LOCATION LEGAL MYERES CONST TiSNRiWS20 L84 PO BM 25i CHUGIAK LOT SIZE 54000 SQUARE FEET TYPE OF SOIL ABSORPTION SYSTEM IS: TRENCH MAXIMUM NUMBER OF BEDROOMS SOIL RATING (SQ FT?BR)= 2~8 THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: [:.EF"T H= 7. 5 LE[4"-STH= --'-': ± :=: ,3R R %-'EL [:,EPTH= 2~ THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRAINFIELD. THE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE AND THE BOTTOM OF THE E~CBVRTION (IN FEET). RE[:" SEF'T I C: TRNK S I ZE= 22513~ ~_SRLLElf4S PERMIT APPLICANT HRS THE RESPONSIBILITV TO INFORM INSTRLLATION INSPECTIONS OF ANY WELLS RDJRCENT TO HUMBER OF RESIDENCES THAT THE WELL WILL SERVE. THIS DEPARTMENT DURING THE THIS PROPERTY RND THE BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS ±00 FEET FOR A PRIVATE WELL OR ±50 TO 200 FEET FROM A PUBLIC WELL DEPENDING UPON THE T~PE OF PUBLIC WELL. MINIMUM DISTANCE FROM A PRIVATE WELL TO A PRIVATE SEWER LINE IS 25 FEET AND TO A COMMUNITY SEWER LINE IS 75 FEET. OTHER REQUIREMENTS MAY RPPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVBILABLE TO INSURE PROPER INSTALLATION. F"EF-:i-"'I :[ T' E::'=:F' 'ii' F~'ES [:.E¢-:E ~-'IBE F." -----=:t.. t.~qE:--TM I CERTIFY THAT ±: I AM FAMILIAR WITH 'THE REQUIREMENTS FOR ON-SITE SEWERS RND WELLS AS SET FORTH BV THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTFILL THE SYSTEM IN AC:COR[:,AHCE/4~4ITH ~H~ COD~S. 2: I UNDERSTRN[:, THRT THE GN-SITE/SEWER S'~T~i'I h'lR~ REQUIRE ENLRRGEMENT iF THE RESICENCE IS REMODELEB TU IHZ:LLC~ MERE T~RNI~: BEDRF-M'~ ~ . _~ - ~ ....... ~ If * APPLICANT~ t"lk~ CONSF/ ¢ V -- "Y I~l~I ¢ - .~ [] SOILS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG -- PERCOLATION TEST PERCOLATION TEST 3 ,gCc go 13- 14- 15- 16- 17- 18- 19- 20- COMMENTS SLOPE SITE PLAN WAS GROUND WATER y ~_~ ~ ENCOUNTERED? ~ IF YES, AT WHAT i/~_/ E Gross Net Depth to Net Reading Date Time Time Water Drop : :., 2o /o.,:: 6 % PERCOLATION RATE TEST RUN BETWEEN % PERFORMED BY: 72-008 (6/79) DEPARTMENT OF NATURAL RESOURES Division of Gsologicol & Geophysicol Surveys gTol,,A.C.' A.o D"ECT'O" ''OM "OA0 I"TEN,ECTlO,, ,.OW,E, OFWELL= ~ ~. Sfree+ Ad~e~l and Aria of Will Locaflo~ 2. WELL LOG Feet Oelow 4. WELL__DEPTH:r(final) 5, DATE OF COMPLETION_ ........... M oterlol Type Top 80tram ~ft. _ _ -'P~ ......... *~ .~ o ...,..., - F~~~' , ,~ -~,~' ,.c.~, ~T~,..,.~ ~ /7 ,l,,. *...o ~ ,,. o,p,h w.~,~, -. ,./,,, ' ~/ ~// diem. In, to fl, Depth lfllkul , fl, -.- lO, STATIC WATE~ LEVEL: ft. .................. fi, after .bra. pumping 00.bm, ~ Jet ~ Centrifloal 0 Other ~ 0~ · 5~5 ' APPLI¢ -NT FILLS OUTUPPER HA[- ONLY Property Owner .~,~? YL~ ~ ~ 0/~/3/~L~[/~ ~ Phone Mailing Addre~ /~? F ~-~ ~ ~ / Zip Code ~-~ ~y- ~/~ Buyer Zip Code Address ~ Lending Institution /:/IC~ ~"~) ~:~ ~ ~.. Phone Address ~/( ~ (/2 ,~//~/~ . ZiP C°de ~ ~ Realty Co. & A~nl Phone Address Zip Code Street Locati~ Type of Resi~nce ~ Single Family ~le Family No. of Bedrbo~ ~ y~ ~L ~ Water S pply Individual A~ACH WELL LOG. A w~l log is required for ag wells drilled since June 1975. ~mun[ty For wells drilled prior to that date, give well depth (attach log if available). ~ Pubgc Utility Sewer Disposal n~]vidual Year ~ndividua~ Installed: /~ blic Utility When Connected to Public Uti~ty~ ~ ~ Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH RE~EST BEFORE ~OCESSlNG CAN BE tNITIATED. Time Time Time Time Date Date Date Date Inspector Inspector Inspector Inspector Field Notes: .~ ~n__~. .... Mu,icJpali~,,Dep.. ....... '*'CONdlT NS oF APPROVAL fi (~)( ) APPROVEDDisAPmOvEDBEDROOMS ~ ~. ~~ ~ Protection" ( ) CONDITIONAL APPROVAL' lled Well To ~sorption Area Well Log Received SOHs Rating Date ~ Well to Tank Septic T~k Size 72.023 (3/82) I I /- MUNICIPALITY OF ANCHORAGE Development Services Department Phone: (907)343-7904 On -Site Water & Wastewater Section Fax: (907)343-7997 Parcel ID 051 -302-29 Certificate of On -Site Systems Approval OSC251553 Expiration Date: 12/9/2026 Legal description T1 5N R1 W SEC 30 LT 84 Site address 19111 STEPHANIE BLVD Current property owner(s) OWEN MICHAEL F X The On-site system(s) is/are approved for 8 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or conditions: No comments By-./ Original Certificate Date: 12/30/2025 This rtificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject sy em(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, development Service Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's submittal. ATTACHMENTS: COSA Checklist X Well Flow Advisory X Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 051-302-29 Complete legal description T15N R1W Sec 30 Lot 84 Location (site address) 19111 STEPHANIE BLVD Current property owner(s) Michael Owen 2. ON-SITE SYSTEMS SIZED FOR 8 BEDROOMS Day phone 3. TYPE OF WATER SUPPLY: A Private Well serving # I dwelling units ❑ Other Non-public well as regulated by MOA ❑ Water Storage ❑ Community Well or Public 4. TYPE OF WASTEWATER DISPOSAL: I Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank E Community Septic or Public Sewer 5. SEPTIC TANK: X Steel ❑ Plastic ❑ Concrete ❑ Fiberglass Age 7 - See advisory if steel or fiberglass older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑E Deep Trench ❑ Wide Trench ❑ Seepage Pit Waiver request for: ADEC Septic Distance: Expedited review requested: ❑ By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $_ 25(/ Date of Payment IZNOS COSA# 05(ZS01 Waiver Fee $ Date of Payment Waiver # COSA App11ca0on_Ap2025.doc Legal Description: COSA Checklist T15N R1W Sec 30 Lot 84 Parcel ID: 051-302-29 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system A. WELL DATA F/❑ Well log is filed with Onsite (or attached) Well production at time of test 0.35 gpm Date drilled 2/911983 Total depth 245 ft Water storage tank volume 800 gallons Cased to 30 ft Well disinfected for coliform test? ❑ Yes No ✓❑ Sanitary seal is functioning correctly ✓❑ Coliform bacteria is Negative ❑� Wires are properly protected Nitrate mg/L ❑✓ Nitrate less than MRL (ND) Casing height (above ground) 25 in. Arsenic ug/L ❑✓ Arsenic less than MRL (ND) Date of flow test for COSA 12/15/25 Collected by Arcterra Consulting Static water level at beginning of test __2,&_ft. Date 1219/25 Comments Southern most well used for COSA well flow test. Water sample from combined water spigot from all 3 wells on property. . DATA ADEC Septic Measured operating flus tic tank Date of pumping ❑ Required maintenance completed, if AWWTS Comments: DISPOSAL FIELD DATA ADEC Septic Which tem tested (date installed) ❑ ALL stan ' s present per record drawing Total measured dept m grade ft (max) Measured depth to pipe inve om grade ft (min) ❑ N/A — pressurized field. ❑ Per record drawings, field is insula ❑ Monitor tubes go to bottom of effective. If not, state depth into effective ❑ Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) If yes, enter date Comments/Deficiencies. COSA Cheddist_May2025.docx C. LIFT STATION ❑ Required maintenance completed A e of lift station years Lift station ma Comments: Adequacy test date Results II Pass Fluid depth prior to test in Water added gal New fluid depth in Elapsed time min Final fluid depth in Absorption rate gpd 7LD STATUS — POST RECOVERY EffectE depth (per record drawings) Effective dep sed in Effective depth ramal in in E. SEPARATION DISTANCES From Well on Lot to: (Please enter distances if less than required) Septic Tank/Lift Station on Lot > 100' 0 Yes if No ft Neighboring Tank > 100' M Yes if No ft Disposal Field on Lot > 100' ✓❑ Yes if No ft Neighboring Disposal Fields > 100' ✓❑ Yes if No ft Sewer Line/Main > 100' ❑✓ Yes if No ft Sewer Manhole/Cleanout > 100' ❑✓ Yes if No ft Sewer Service/Septic Line > 25'Z Yes if No ft Holding Tank > 100' ✓❑ Yes if No ft Animal Containment > 50' ✓❑ Yes if No ft Manure/Animal Excreta Storage > 100' Tank to Property Line > 5' ❑✓ Yes if No ft ❑ N/A — Served by Community Well (not on lot) or Public Water eptic/Holding Tank and Disposal Field(s) on Lot to: (Please enter distances if less than required) Tank to Foundation > ❑ Yes if No ft Surface Water > 100' ❑ Yes if No ft Field to Foundation > 10' ❑ Yes ft Wells on Adjacent Lots: Tank to Property Line > 5' ❑ Yes if No ft IIs > 100' ❑ Yes if No ft Field to Property Line > 10' El Yes if No ft Community We Mrivew�ay Yes i�No ft Water Main/Service Line > 10' ❑ Yes if No ft If tank or field is undemme ADEC Septic F. ENGINEER'S COMMENTS G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Arcterra Consulting Phone (907)-696-6111 Engineer's Printed Name Kenneth Duffus Date Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the i��r*s►�� conditions as of the day tested. The flow and absorption rates may change due to 4 e s��,G 01, -Ai- * subsurface conditions that may not be observed from the surface, changes inland use, local # soil characteristics, groundwater levels that may fluctuate during the year and the water i usage of the family being served by the system. The operational life of all well and septic * . systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, ArcTerra can not give any estimate of how long a system will function satisfactory for current or future occupants f i{E4VETI s V. S 4J or can ArcTerra guarantee that no unseen encroachments, deficiencies or discrepancies ri >> , 5 exist. ■ COSA Cheddist_1V1ay2025.docx Legal Description: COSA Checklist T15N R1W Sec 30 Lot 84 Parcel ID - 051 -302-29 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system A. WELL DATA Well 2 (middle well) ❑ Well log is filed with Onsite (or attached) Date drilled UNK Total depth UNK ft Cased to UNK ft 0 Sanitary seal is functioning correctly ❑v Wires are properly protected Casing height (above ground) 23 in. Date of flow test for COSA 12/15/25 Well production at time of test 0.35 gpm Water storage tank volume 800 gallons Well disinfected for coliform test? ❑ Yes✓❑ No ❑2 Coliform bacteria is Negative Nitrate mg/LNitrate less than MRL (ND) Arsenic ug/L ❑✓ Arsenic less than MRL (ND) Collected by Arcterra Consulting Static water level at beginning of test 28 ft. Date S Comments Southern most well used for COSA well flow test. Water sample from combined water 3 wells on property. DATA Measured operating ADEC Septic tank Date of pumping ❑ Required maintenance completed, if AWWTS Comments: DISPOSAL FIELD DATA ADEC Septic tested (date installed) ❑ ALL Stan -S" resent per record drawing Total measured dept m grade ft (max) Measured depth to pipe inve m grade ft (min) ❑ N/A -pressurized field. F-1 Per record drawings, field is insula ❑ Monitor tubes go to bottom of effective. If not, state depth into effective ❑ Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) If yes, enter date Comments/Deficiencies COSA Cheddist_May2025.docx C. LIFT STATION ❑ Required maintenance completed Age of lift station years Lift station Comments: Adequacy test date Results ❑ Pass Fluid depth prior to test in Water added gal New fluid depth in Elapsed time min Final fluid depth in Absorption rate gpd MELD STATUS - POST RECOVERY from all Effec=depthper record drawings) in Effecsed in Effective depth in E. SEPARATION DISTANCES From Well on Lot to: (Please enter distances if less than required) Septic Tank/Lift Station on Lot > 100' 0 Yes if No ft Neighboring Tank > 100' 0 Yes if No ft Disposal Field on Lot > 100' 0 Yes if No ft Neighboring Disposal Fields > 100' 0 Yes if No ft Sewer Line/Main > 100' 0 Yes if No ft Sewer Manhole/Cleanout > 100' 0 Yes if No ft Sewer Service/Septic Line > 25'Z Yes if No ft Holding Tank > 100' 0 Yes if No ft Animal Containment > 50' 0 Yes if No ft Manure/Animal Excreta Storage > 100' ❑ Yes if No 0 Yes if No ft ❑ N/A — Served by Community Well (not on lot) or Public Water eptic/Holding Tank and Disposal Field(s) on Lot to: (Please enter distances if less than required) Tank to Foundation ? ❑Yes if No ft Surface Water > 100' El Yes if No Field to Foundation > 10' ❑ Yes i ft Wells on Adjacent Lots: Tank to Property Line > 5' ❑ Yes if No ft IIs > 100' ❑ Yes if No Field to Property Line > 10' ❑ Yes if No ft Community We _ 0' ❑ Yes if No Water Main/Service Line > 10' ❑ Yes if No ft If tank or field is under driveway comme ADEC Septic F. ENGINEER'S COMMENTS ft ft G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Arcterra Consulting Phone (907)-696-6111 Engineer's Printed Name Kenneth Duffus Date ,2&4C - Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to theOF conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes inland use, local = � *� soil characteristics, groundwater levels that may fluctuate during the year and the water usage of the family being served by the system. The operational life of all well and septic *� * A systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, ArcTerra can not give i any estimate of how long a system will function satisfactory for current or future occupants 4i Fi1JS1a;ii or can ArcTerra guarantee that no unseen encroachments, deficiencies or discrepancies CE 116 exist. �f * I� J;0�� r COSA Cheddist_May2025.docx CASA Checklist Legal Description: T15N R1W Sec 30 Lot 84 Parcel ID: 051-302-29 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system A. WELL DATA Well 3 (North well) ] Well log is filed with Onsite (or attached) Date drilled UNK _Total depth UNK ft Cased to UNK ft 0 Sanitary seal is functioning correctly ❑/ Wires are properly protected Casing height (above ground) 28 in. Date of flow test for COSA 12/15/25 Well production at time of test 0.35 gpm Water storage tank volume 800 gallons Well disinfected for coliform test? ❑ Yes✓❑ No ✓❑ Coliform bacteria is Negative Nitrate mg/L❑ Nitrate less than MRL (ND) Arsenic ug/L ❑✓ Arsenic less than MRL (ND) Collected by Arcterra Consulting Static water level at beginning of test _15 _ft. Date12/9/25 Comments Southern most well used for COSA well flow test. Water sample from combined water 3 wells on property. DATA Measured operating ADEC Septic tank Date of pumping ❑ Required maintenance completed, if AWWTS Comments: DISPOSAL FIELD DATA ADEC Septic Which tem tested (date installed) ❑ ALL Stan i s present per record drawing Total measured dept m grade ft (max) Measured depth to pipe inve m grade ft (min) ❑ N/A — pressurized field. ❑ Per record drawings, field is insula ❑ Monitor tubes go to bottom of effective. If not, state depth into effective ❑ Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced _gallons date Any rejuvenation treatment (past 12 months) If yes, enter date Comments/Deficiencies COSA Cheddist_May2025.docx C. LIFT STATION ❑ Required maintenance completed Age of lift station years Lift station Comments: Adequacy test date Results II Pass Fluid depth prior to test in Water added gal New fluid depth in Elapsed time min Final fluid depth in Absorption rate gpd HELD STATUS — POST RECOVERY from all Effec=dep er record drawings) in Effecsed in Effective depth in E. SEPARATION DISTANCES From Well on Lot to: (Please enter distances if less than required) Septic Tank/Lift Station on Lot > 100' ✓❑ Yes if No ft Neighboring Tank > 100' F7 Yes if No ft Disposal Field on Lot > 100' ✓❑ Yes if No ft Neighboring Disposal Fields > 100' ✓❑ Yes if No ft Sewer Line/Main > 100' ❑✓ Yes if No ft Sewer Manhole/Cleanout > 100' ✓❑ Yes if No ft Sewer Service/Septic Line > 25'Z Yes if No ft Holding Tank > 100' ✓❑ Yes if No ft Animal Containment 2:50' 0 Yes if No ft Manure/Animal Excreta Storage > 100' ❑✓ Yes if No ft ❑ N/A — Served by Community Well (not on lot) or Public Water F eptic/Holding Tank and Disposal Field(s) on Lot to: (Please enter distances if less than required) Tank to Foundation > ❑ Yes if No ft Surface Water > 100' ❑ Yes if No ft Field to Foundation > 10' ❑ Yes Tank to Property Line > 5' ❑ Yes Field to Property Line > 10' ❑ Yes Water Main/Service Line > 10' ❑ Yes F. ENGINEER'S COMMENTS ft Wells on Adjacent Lots: if No ft IIs > 100' if No ft Community We _ if No ft If tank or field is under driveway ADEC Septic ❑ Yes if No ft ❑ Yes if No ft G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Arcterra Consulting Phone (907)-696-6111 Engineer's Printed Name Kenneth Duffus Date _ -1 L &o y� Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the ��x�aa conditions as of the day tested. The flow and absorption rates may change due to ����� � subsurface conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that may fluctuate during the year and the water i ` usage of the family being served by the system. The operational life of all well and septic �7 *� systems are subject to these various and dynamic characteristics and are outside the 1 4921 control of the evaluator of the well and septic system. Therefore, ArcTerra can not give 0 any estimate of how long a system will function satisfactory for current or future occupants ,�yyfm rFt1S 4, or can ArcTerra guarantee that no unseen encroachments, deficiencies or discrepancies *1� CE 7i exist. 44 y� + tF" COSA Chedclist_May2025.docx arR�*fw»���; MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT1 Al� 907-343-7904 On -Site water and wastewater Section Fax: 343-7997 www.muni.org/onsite Well Water Advisory Certificate of On -Site Systems Approval # OSC251553 Subdivision: T15N R1W, Block: Section 30, Lot: 84 This well's productivity was determined to be .35 gallons per minute. The recommended well productivity under (AMC 15.55) for a 8 -bedroom residence is .83 gallons per minute or 150 gallons per day per bedroom. Water storage may be necessary to accommodate your needs. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval.