HomeMy WebLinkAboutTHUNDERBIRD HEIGHTS #3A BLK 6 LT 2Thund rbird Heights lock 6 Lot 2 051 - 582 -47 Municipality of Anchorage Development Services Department i~ltf~ [.l12d~ Building Safety Division On-Site Water and Wastewater Program, 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 Page of www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL iNSPECTION REPORT Permit Number: 0sP101104 PID Number: 051-582-47 Name: Barry and Terri Schimmack Wastewater System: [] New [] Upgrade Address: 24888 Teal Loop Chugiak, AK 99567 ABSORPTION FIELD Phone: Number of Bedrooms: 4 [] DeepTrench ~ Shallow Trench [] Bed [] Mound [] Other: LEGAL DESCRIPTION Sci, Rating: Total Depth from odginal grade: 1.2 GPD/Ft2 4 Ft. Block: 6 Lot: 2 Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: Thunderbird Hts. No. 3A 1 Ft. 3 Ft. Township: Range: Section: Fill added above original grade: Gravel Length: 2.7 Ft. 65 Ft. Well: [] New [] Upgrade Gravelwidth: 5 Ft. Numberofiines:l Distance between lines:_ Ft. Classification (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material: AVVVVU Ft. Ft. 560 Ft2 ASTM D3034 PVC Ddller: Date Drilled: Static Water Level: installer: Date Installed: Ft, Royce Martin 10/13-15/2010 Yield: GPM PumpSetat: Ft. CasingHeightAboveGround: Ft. TAN K SEPARATION DISTANCES [] Septic [] Holding [] S.T.E.P. [] Other: T~To Septic Absorption Lift Holding ~ublic/Private Manufacturer: Capacity: From~ Tank Field Station Tank Sewer Line Anchorage Tank 1,250 Gal. Material: Number of Compartments: Well N/A N/A N/A N/A >25' Steel Two (2) k · surface water >100' >100' N/A N/A ~ ~ LIFT STATION Size: Manufacturer: Lot Line >5' 1 .... N/A N/A Gal. "Pump on" level at: "Pump off" level at: in. High water alarm at: Foundation >5' > 10' N/A N/A in. in. Curtain Drain None Noted Pump Make & Model Electrical Inspections performed by: Remarks: · **See Lot Line Waiver. BENCH MARK Location and Description: Exterior Deck. Assumed Elevation: 100.0 Et, Inspections performed by: A. Harala Dates: 1't 10/13-14/10 2nd 10/15/2010 Development Services Department Approval Conditional Approval Date: Reviewed and approved by: ~:~.~ 9 fi:;~,'///~/, ate: .;,~. ' / Permit Number: OSP101104 Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 THUNDERBIRD HEIGHTS SUBDIVISION NO. 5A LOT 2, BLOCK 6 22,369 S.F. Page 2 of 3 PID No.: 051-582-47 S2 48.4123.1 S1 18.8121.5 C5 57.9148'9 M1 80.0 63.0 M2 65.7 52.9 Existing 24' x 40' Absorption .Bed. Existing Tank Decommissioned In Accordance With Municipol Code. M2 e(~room ~ome LEGEND Sl - Septic Vent C4 - Cleon Out M1 - Monitor Tube FCO - Foundotion Cleon Out FDV - Flow Diverter Velve [] - Existing [] - Proposed NOTE: Subdivision Served by Community W(~ter System. No Conflicts with Adjacent Septic Systems. PLAN AS SCALE 1" = 40' BUILT NOTE: Drawing Not Completed from Surveyor As Built. Locot~ons Mey Not Be Ex(~ct. Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 EImore Road Anchorage, AK. 99519-6655 - 343-7904 On-Site Wastewater Disposal System or Well Inspection Report Permit Number: OSP101104 Page 3 of 3 PID No. 051-582-47 94.8 Final ~de 92.1 ound Original 2' s t n ...................... nuao Geotext e FabTic Geotextile Fabric _ _ ~~ 91.2 91.2- --~ Drainfield Rock 88.1--/ 88.1 ~ 82.1 I 65' (Trench Length) I PROFILE AS-BUILT No Scale On-Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 EImore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP101104 Tax Code Number: 05158247000 Work Type: Septic Upgrade Permit Effective Dates: July 09, 2010 to July 09, 2011 Design Engineer: ANDERSON ENGINEERING Subdivision: THUNDERBIRD HEIGHTS #3A Site Legal Address: THUNDERBIRD HEIGHTS #3A BLK Owner/Address: SCHIMMACK BARRY & TERRI A 24888 TEAL LOOP CHUGIAK AK 995675114 6 LT 2 G:1865 /.2.: Site Mailing Address: 24888 TEAL LOOP, Chugiak Lot Size in Sq Ft: 22369 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field Y SepticTank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Murticipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: Permit includes waiver OSP101105 allowing the drainfield to be 1 foot from the property line. Munica of Anchorage ip lity P.O. Box 196650 · 4700 Elmore Road Anchorage, Alaska 99519-6650 · (907) 343-7904 · Fax (907) 343-7997 http:llwww.muni.orglOnsite Development Services Department On-Site Water and Waste~vater Program **** VARIANCE/WAIVER REVIEW **** WR#: OSP101105 HA#: Permit: OSP101104 PID#: 051-582-47 Legal Description: Thunderbird Heights #3A, Block 6, Lot 2 Engineer: Anderson En,qineerin,q Applicant: Barry Schimmack .Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 1.0 foot. This waiver approval applies to the existing absorption field to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. Waiver is Granted: X Waiver is not Granted: Date: ..... 9/29/2010 Approved b~~~~ ~,,fN~me of Reviewer ' Rec~: 04596C Amount: $200.00 Date Paid: 6/30/2010 **** VARIANCE/VVAIVER REVIEW **** On-Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP101104 Tax Code Number: 05158247000 Work Type: Septic Permit Effective Dates: July 09, 2010 Design Engineer: STEVE ENG Subdivision: THUNDERBIRD HEIGHTS #3A Upgrade to July 09, 2011 Site Legal Address: THUNDERBIRD HEIGHTS #3A BLK 6 LT 2 G:1865 Owner/Address: SCHIMMACK BARRY & TERRI A 24888 TEAL LOOP CHUGIAK AK 995675114 Site Mailing Address: 24888 TEAL LOOP, Chugiak Lot Size in Sq Ft: 22369 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field Y SepticTank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: Permit includes waiver OSP101105 allowing the drainfield to be 1 foot from the property line. Issued By: ...~53 ~.///~o¢ ~ [/~/~¢-'¢~ Date: Date: Municipality of Anchorage P.O. Box 196650 ® 4700 Elmore Road Anchorage, Alaska 99519-6650 · (907)' 343-7904 · Fax (907) 343-7997 .h.ttp:!lwww.m u ni.or.qlOnsite Develor~ment Services Department On-Site Water and Wastewater Program **** VARIANCEFWAIVER REVIEW **** WF~: OSP101105 HA#: Permit~: OSP101104 PID~: 051-582-47 Legal Description: Thunderbird. Heights #3A, Block 6, Lot 2 Engineer: North Rim En,qineedn,q Applicant: Barry Schick Your request for a waiver of the required 10 feet hOrizontal separation from the absorption field to the property line has been approved. The approved separation distance is 1.0 foot. This waiver approval applies to the existing absorption field to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval 'from this.department. Waiver is Granted: X Waiver is not GranteAJ: .~ Da : 7/9/2010 ApProved [ /Yl~ameof'Revi~wer v Recg: 04596C Amount: $200.00 Date Paid: 6/3012010 **** VARIA~NC,E~AIVER ,REVIEW **** Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, Alaska 99507 www. muni.org/onsite (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION 'F~,'~'o-v~c~: O-CPl¢l( ~.~,~ FOR A SINGLE FAMILY DWELLING Parcel I.D. 4~'/- '~c'(JC'Z'~'/' "~--<3oo Property owner(s)/~ ~'¢'r~' Mailing address~/--/' 0 Day phone Zip Code Site address '~r.+~ ~_ Zip Code Legal description (Sub'd., Block & Lot) Legal description (Township, Range & Section) Lot Size 2 2/ ..~ ~"7 Sq. Ft. Number of Bedrooms THIS APPLICATION IS FOR ([~ all that apply): Absorption Field Septic Tank Holding Tank Privy Private Well Water Storage THIS APPLICATION IS AN: Initial [] Upgrade ~'- Renewal [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: ,,~-- 3 ~ Waiver Fees: Date of Payment: ~ - ~ C'~ - //~; Date of Payment: Receipt Number: ~ ~ ~ ~ ~ Receipt Number: (Rev. 11/05) ANDERSON ENGINEERING P.O* BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) September 25, 2010 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 Elmore Road Anchorage, AK 99519-6650 Subject: Lot 2, Block 6, Thunderbird Hts. Subdivision, Addn. 3A Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The existing absorption system on the subject lot has failed and must be upgraded to prevent a health hazard. We are therefore requesting a permit be issued for the upgrade of the septic system to accommodate the four-bedroom home on the lot. The attached Site Plan and backup documentation identify the location and configuration of the existing and proposed septic system. The existing 1,250 Gallon septic tank will be pumped, crushed and backfilled on site. The existing absorption bed system will be tied in to the new system with a flow diverter valve. The new septic tank and absorption trenches will be placed as shown. Also identified on the plans are the locations of the existing water service on this lot and adjacent septic systems. No conflicts exist between the proposed septic system and the water service on this or adjacent lots. The subdivision is served by a community water system. Drainage arrows are shown indicating the current drainage patterns. The drainage patterns will be maintained after construction. The test holes recently placed on the lot indicated sand with some silt (SW). The percolation rate was determined to be 1 to 5 minutes per inch. We have designed the system to an application rate of 1.2 gallons per day per square foot. We are proposing to place a 1,250 gallon septic tank and 2 - 30' long trench by 5' wide trenches with a 3' effective depth. The total depth of the system will be 4'. A flow splitter valve will be placed to assure even flow to each trench. A flow diverter valve will also be placed to tie in the old absorption bed. The ground surface on the lot slopes to the northwest in the area of the absorption trench at a slight grade. The trench will be placed parallel to the contours of the ground Lot 2, Block 6, Thunderbird Hts. No. 3A September 25, 2010 Page Two as much as possible and in conformance with design criteria. A minimum of 100' will be maintained between all components of the septic system and any surface water in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (F~) September 29, 2010 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Lot 2, Block 6, Thunderbird Heights Subdivision No. 3A Separation Distance Waiver Absorption Trench to Lot Line Dear On Site Services Engineer: Lot 2, Block 6, Thunderbird Heights Subdivision No. 3A is a small lot with only 22,369 square feet of surface area. The existing septic system has failed and must be replaced with a new four bedroom system. A test hole recently placed at the southeast corner indicates sandy soils which will support a new absorption system. This area, however, encroaches into the 10' setback from the property line on the east side. Placement of the absorption trench within 1' of the eastern lot line will not adversely affect neighboring lots. The subdivision is served by a public water system and all service lines are more than 10' from the septic system as designed. We hereby recommend a lot line waiver be issued allowing placement of the absorption system within 1' of the eastern lot line. Sincerely, Michael E. Anderson, P.E. ~ 12 NOTE: No Conflicts with Wells or Septic Systems in the Area. Surrounding Lots Served by Public Water System. No Slopes Greater than 25% Within 50' of the New Absorption Trenches. ~..~~:~ A R E A M AP ee_~x_;.~_~_~.~..~,~ ~ ~--SCALE = 100' THUNDERBIRD LOT HEIGHTS 2, BLOCK 22,569 S.F. SUBDIVISION' 6 NO. 3A / / / / / /  Existing 24' x 40' Absorption Bed. Dispose of Existing Ta?k In Accordance With Municipal Code. Place New 1,250 Gallon Septic Tank, Two Post Tank Cleanouts, Flow Diverter Valve, Flow Splitter Valve and Two ,30' Long x 5' Wide x Effective Depth Absorption Trenches. -1' ec~roorn Borne LEGEND SV - Septic Vent CO Clean Out MT - Monitor Tube FCO - Foundation Cleon Out FDV - Flow Diverter Valve FSV - Flow Splitter Valve [] - Existing [] - Proposed o*; ~. ......... ~, ~,,~xY..: ...... ~%, NOTE: NOTE: ~ ~2 q ~ ~ ~ ~ to be Located by Registered Land ~'~,,~;~:.'.;--~,,,~,,,,~..~ Suweyor Prior to Construction. ~2(nX No CE-4381 Z ~ SI TE PLAN '~~ SCALE 1" = 40' Subdivision Served by Community Water System. No Conflicts with Adjacent Septic Systems. LOT 2, BLOCK 6, THUNDERBIRD HEIGHTS SUBDIVISION, ADDN. 3A DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home 5' Wide Trench System Perc. Rate: 1-5 Min./Inch 1,250 Gallon Septic Tank Application Rate: 1.2 GPD/SF 3' Drainfield Rock 4 Bedrooms X 150 GPD/1.2 GPD/SF (Application Rate) = 500 SF Absorption Area 500 SF/5 SF/LF*.58 (Red. Factor) = 58 LF Trench Length THEREFORE: Construct 2-30' Long x 5' Wide x 3' Effective Depth Absorption Trenches at the Location Shown. Flow Line Elevation in Trench to be 1'0" Below Original Ground Surface. Total Depth to be 4' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. Place a Flow Diverter Valve to Tie in Existing Trench and a Flow Splitter Valve to Insure Even Flow to Each New Trench. ~ N'~tural~'~'"~ Backfill ~ 6" Geotextile ~-- Fabric 6" ~('~ 4" Perforated PVC (Holes Down) Drainfield Rock TYPICAL 5' WIDE TRENCH SECTION - - --(~-b--~c~ .... NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation FromSeparati°n From Bedrock._~'~""'/"'"'~' ~~.. ~ ................... , ..... Minimum 4' Groundwater. Minimum 100' Separation From Wells in the Area. Minimum 100' Separation From Su¢ace Water or Streams. . &700 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT ELMORE ROAD ANCHORAGE, AK c)c)51c9-6650 SOILS LOG - PERCOLATION TEST LOT 2, BLOCK 6, THUNDERBIRD HTS. 3A BARRY SCHIHMACK LEGAL DESCRIPTION: PERFORMED FOR: DATE: 9/23/10 PARCEL ID#: TEMP: 55° DEPTH (feet) 1 0B/OG 2 3 4 5 SW 6 7 8 9 PROJECT No.: 05 I-582-47 TECHNICIAN: TEST HOLE A LOOSE, WELL GRADED, DRY SAND, BLACK SUART GILBERT SLOPE SITE PLAN SEE SITE PLAN 20 BEDROCK WAS GROUND WATER ENCOUNTERED? No IF YES ~ WHAT DEPTH? ! ] DEPTH OF WATER AFTER MONITORING: NON~ DATE OF MONITORING: 9/30/I0 DEPTH OF DATE READING GROSS TIME NET TIME WATER NET DROP (MINUTES) (MINUTES) (INCHES) (INCHES) 9/23/10 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 4:08/4:18 l0 10.75/1.75 9.00 2 1140/1150 10 10.50/1.63 8.87 3 1150/1200 10 10.75/1.75 9.00 4 1200/1210 10 10.63/1.63 9.00 5 1210/1220 10 ,10.50/1.50 9.00 6 1220/1230 10 10.75/1.75 9.00 PERCOLATION RATE: I. I ,(MIN/INCH) PERC. HOLE DIA. 6 (iNCHES) TEST RUN BETWEEN: 3 FT. and h ,FT. COMMENTS: TEST CAVITY PRE SOAKED PRIOR TO PERCOLATION TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 2, BLOCK 6, THUNDERBIRD HEIGHTS SUBDIVISION, ADDN. 3A GENERAL: The scope of this project includes the pumping, crushing and backfilling of the existing septic tank currently on site. Work also includes the furnishing and placement of a new 1,250 gallon steel septic tank and the construction of 2 new 30' long X 5' wide X 3' effective depth absorption trenches at the location also shown on the Site Plan. The distribution line in the trenches will be placed at 1' below the existing ground surface. Total depth of the trenches will be 4' below the existing ground surface. The new absorption trenches must be placed a minimum of 100' from any surface water in the area and 10' from the water service line on this and adjacent lots. A minimum of 3' of cover is required over the absorption trench and 4' over the septic tank. A flow diverter valve must be placed to tie in the existing absorption bed for future use. A flow splitter valve must be placed to insure even flow to each new trench. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor must also verify the location of wells in the area and assure that the separation distances are met. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. Contractors installing wastewater disposal systems must be certified by the Municipal Development Services Department Building Safety Division On Site Water and Wastewater Program for system installations. Owners installing their own systems must receive prior approval from the On Site Water and Wastewater Program before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 1,250-gallon septic tank must be procured from an approved source and installed at the location shown. Lot 2, Block 6, Thunderbird Heights No. 3A September 25, 2010 Page 2 of 3 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below the distribution line must be perforated. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. Lot 2, Block 6, Thunderbird Heights No. 3A September 25, 2010 Page 3 of 3 MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as-built of the completed system. M '! EERING MEMO Steve Eng, PE, PH P.O. Box 770724, Eagle River AK 99577 (907) 694-7028 tel northrimeng@aol.com Date: 6/29/10 Number of Pages: To: MOA On-Site Services Subject: Thunderbird Hts #3A, Block 6, Lot 2 The subject property septic tank has failed. We are replacing the entire septic system with a new 1250 gallon septic tank, followed by a parallel absorption trench. Excellent soil was evident in the test hole. Public water serves the area lots and are shown in drawings. The owner wishes to obtain the permit as soon as possible, since the tank has failed. We are requesting a 1' lot line waiver due to the tight configuration. The old leach field will be connected via a valve. Please review the wastewater system design for the single family home. I have included design plans & specs, design guidelines, & soil tests. If them is need for additional information or clarification please give me a call. Thanks-Steve THRIM Thunderbird Hts #3A, Block 6, Lot 2 SPECIFICATIONS & DESIGN GUIDELINES Wastewater System Sizing: This is an existing 4-bedroom, single family home. The septic tank has failed. Upon inspection it was found that the absorption trench was flooded. A new design is submitted for a new trench & new septic tank. The neighboring lots are developed as indicated in the drawing. New soil tests were conducted. A 4' deep trench will be excavated with new septic tank. The old tank will be removed or properly abandoned in place. No water wells are in the area. Public water serves all the neighboring lots. No adverse impacts are expected from septic system replacement. No conflicts to the other lots will take place by this septic system construction. The easements are located on the drawing and are not encroached upon. The soil tests revealed a clean sand soil. A conventional septic system will be used, application rate of 1.2 GPD/FT2. Trench Length = 500 FT2/5'x 0.58 reduction factor = 58'; 2 lines ~ 29', 3' effective depth. Old leach field will be connected via "Bull Run Valve". Due to the lack of room, a lot line waiver is requested to 1'. Specification Requirements: All components and work must comply with the Municipality of Anchorage Specifications (AMC) & State of Alaska Drinking Water Regulations and Wastewater Regulations. · Two compartment, 1250 gallon septic tank. Watertight couplings on inlet & outlet. · 5' minimum between the tank and bed. 10' to property lines. · 3' of cover or insulation is required for trench; 1" insulation may be substituted for one foot soil cover. · Tank & solid pipe must be set on well compacted, stable soil. · 4 inch diameter cleanouts with airtight caps are required 1' to 4' from foundation wall, prior to any 90 degree bend in 4 inch line, in each tank compartment, and two adjacent opposing cleanouts between the tank and the absorption field, not more than 10' from the tank positioned to provide cleanout access towards the tank and towards the absorption field. · All cleanouts must extend to at least ground level. · In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron. · Trench to be placed level, minimum of 4' to groundwater, 6' to bedrock from drain-rock. · Drain rock to be ½ inch to 2 ½ inch screened. Drain rock to be distributed uniformly throughout the trench. · Perforated pipe to be installed level with perforations down. · Silt barrier (filter fabric) to be installed above the drain rock. · Smeared trench sides must be raked or scarified before drain rock placement. · Backfill over drain rock must not be less than 36", 24" with 1" insulation. · The finish grade must be mounded to promote drainage over the trench. · Insulation must be placed over any pipe installed under driveways or parking areas. · Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789, ABS ASTM D2661, · Sewer Service Line is minimum 2% slope. · Septic Tank to be pumped every two years or when required. · Insulation board to be extruded direct burial polystyrene (Dow Styrofoam HI or equal) · Old Septic Tank to be removed or pumped, filled with sand/gravel, crushed, & buried. DESIGN NOTES: 1. Total Depth of Trench is 4'. Septic Site is Close To Level Slope. 2. Sewer Service Line minimum 2% slope. 5. Abandon/Decommission Old Septic Tank 4. Lots Serve, tOld Leachfit Line To Old Le, 11Connect To Piping Public Water System. TH \ Gallon Tank Decommission Old Tank --Bull Run Valve To Old Field CB/MT THUNDERBIRD HTS #3A 3LDCK 6 LBT 2 NEW TRENCH/TANK SEPTIC SYSTEM 1' = 40' WASTEWATER ~ LAYBUT i 7/9/10 ¢ 3 ~ Septic System ~ons~ruc~io~ . Does No~ Prec--~de A( '"'l,_o~s From Sai,,rf'~a~ion :~p\rovemen~s, SEPTIC SYSTEM \ \ \ \ \ \ J Bm[ STATI[] =20 28.24 / / / / / / 2 SEPTIC SYSTEM PRF1PDSE] SEPTIC NEW ,'SEPTIC SYSTEM SEPTIC SYSTEM THUNDERBIRD HTS BLE]CK 6, LBT P SUBDIVISIE]N LAYE]UT AREA PLAN 50' ISHEET: 6/29/io ~ Dote: C 0 > 0 0 U' 'q- 0 0 0 0 _C U C (~ (4- 0 C W 0 _Q 0 0 W THRIM Performed For 1 3 4 5 6 - 7 - 8 - 9 - 10 - 11 - 1P - 13 - 14 - 15 - 16 - 17 - 18 - 19 - 20 - 21 - Legal Description: Flrgcnic SW w/GraveL DEPTH (FEET) ~////////~ ,. .~ :...;. ~ :' ~ Comments: Presoaked SOILS LOG - PERCOLATION TEST Date Performed: 5/19/10 3arry Schimmack Thunderbird Hfs ~3A, BLock 6, Lot 8 T,H, Locction: See Attcched Design ~5% SLope Groundwater? No Depth Water Depth AFter Monitorinq, None Date: 5/88/10 $~ Dote Gross Time Net Time Depth Net Drop 1 5/19 0 -- 8 5/19 10 10 mir, 16' 5' 3 5/19 18 11' -- 4 5/19 22 10 mir, 16' 5" 5 5/19 85 -- 11' 6 5/19 35 10 mir, 16' 5' 7 5/19 37 -- 11,, __ 8 5/19 47 10 Mir i~'~ 5" 9 5/19 50 -- 11,, -- 10 5/19 60 10 Mir 16" PercoLation Rate 2 min,/inch Perc HoLe Diameter Test Run ~etween 3' ~nd 4' PerFormed ByNorthRim Eng, I PerFormed in Accordance with ON THIS DATE, DATE: 5/28/10 ~ CERTIFY ALL Sro, re/MunicipaL THAT THIS TEST WAS GuideLines in EFFect NOR THRIM ~,,,~,~..~ PO Box 770724 ~% ;, ~. i~ ':.~! -- TESTHOLE LOG GEOTECHNICAL T, H, 1 5/28/10 T RIM SOILS LOG - PERCF1LATIBN TEST Dance PerFormed: 5/i9/i0 PerFormed For: Barry Schimmcck LeDcL Description: Thunderbird H~s ~3A, BLock 6, Lo~ a 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 10 - 11 - 1P - 13 - 14 - 15 - 16 - 17 - 18 - 19 - 20 - 2i - DEPTH (FEET) ~///////~ · .:'.~. ~...::'.~ s.".".': ~'"/ ~.'.:"~.~ ."~...."~",> :' 'T':: T,H, Loca~cion: See A~c~cached Design FIrD~nic ~5Z SLope SW w/Gr~veL Perk Tes~ Groundwater? No Depth Wa~er Depth AFSer Noni~orin9, None ~ Da~ce Gross Time Ne~c Time Dep~ch Ne~ Drop 1 5/19 0 -- 4,, __ 2 5/19 10 10 mir 9' Sm 3 5/19 12 -- 4, __ 4 5/19 22 10 mir 9~ 5~ 5 5/19 P5 -- 4,, __ 6 5/19 35 10 mir 9" 5" 7 5/19 37 -- 4,, __ 8 5/19 47 10 mill 9,, 5· 9 5/19 50 -- 4" 10 5/19 60 10 mir 9" 5" PercoLc~ion Ra~e 2 min,/inch Perc HoLe Dicme~er 6x Tes~ Run Between 3' and 4' CommenCes: Presoaked , PerFormed :By Nor~chRim Eng, I ~ CERTIFY THAT THIS TEST WAS PerFormed in Accordance wi~ch At[ S~ca~ce/Municipo[ Guidelines in EFFec~c UN THIS DATE, I)ATE: 5/;~8/10 N 01~ THI~IM EN GINEEI~IN ~ 1=0 I9o~ ?70724 Eogle River, AIosko 99577 907.694. 7028 TESTHOLE LUG GEBTECHNICAL T, H, 2 ~ ' MUNICIPALITY OF ANCHORAGE , DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME LEGAL DESCRIPTION LOCATION PHONE [] UPGRADE Well AbsorPtion area Dwelli Manufacturer r Mate:5 bj(. IF HOMEMADE: Inside length DISTANCE TO: Well Dwelling Manufacturer Total len g~c~nes Material beneath tile DIST^NCE*O= Iwe" f'OR¢~ No. of lines ~ I Lengtl~.~eacJ~}ine Top of tile to finish grade ~ ~ I Length Width Material Nearest lot line Tre c wi t o I ,nches Depth NO. OF BEDRO~/S No. of compartment~ Liquid depth PERMIT NO. Liquid capacity in gallons Distance between lines Total effective¢~i~ ,re8 PERMIT NO. Type of crib irib diameter Crib depth Total effective absorption area Well Building foundation Nearest lot line DISTANCE TO: Class Depth Driller Distance to lot line Building foundation Sewer line Septic tank DISTANCE TO: OTHER INSTALLER REMARKS DATE z I APPROVED 72-013 (Rev, 3/78) LEGAL Permit ~ Applicant: Location: Legal Description: ~0~ ~ Type of Soil Absorption System Is: Trench: Drainfield: ~ Maximum Number of Bedrooms: ~ . MUNICIPALITY 0F ANCHORAGE Department/~5 Health and Environmenta3~'¥rotection 825 ,~ Street, Anchorage, AK. ~ ~501 264-4720 * * * HANDWRITTEN PERMIT * * * ON-SITE SEWER PERMIT Ro Mailing Address: Phone, Number: Seepage Bed: Holding Tank: Soil Rating(sq.ft/br) The Required Size of the Soil Absorption System Is:' DEPTH ~ LENGTH ~/ RAVEL DEPTH WIDTH The length dimension is the length(in feet) of the ~ren~O~ or dralnfleld. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between the outfall pipe and the bottom of the excavation(in feet). * * REQUIRED SEPTIC(MSC-D-t-NG) TANK SIZE = /~00 GALLONS * * Permit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. * * * TWO(2) INSPECTIONS ARE REQUIRED * * * Backfilling of any system without final inspection and approval by this department will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 feet for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line is 25 feet and to a community sewer line is 75 feet. Well logs are required and must be returned to this department within 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. * * * PERMIT EXPIRES DECEMBER 3L 1 9 8 3 * * * I certify that: (1) I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2) I will install the system in accordance with codes. (3) I understand that the on-site sewer system may require enlargement if the residence is remodeled to include mor~ tha~3 b~dro?2~ Signe~: ~/%~3 ~z-) Issued by. ,~__~~_ A~plica~ %~ Date: ,~7~2 SOILS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION [] PERCOLATION TEST 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST SLOPE SITE 'P ~]' 1 2 3 4- 5- 6- 7 8 9- 10- 11 13- 14- 15- 16- 17- 18- 19- 20- COMMENTS PE.FORMED 72-008 (6/79) O P E IF YES, AT WHAT DEPTH? Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE TEST RUN BETWEEN FT AND -- FT / CERTIFIED BY: J ~/~x (minutes/inch) • • Municipality of Anchor. • 6 8 9 '0 '' ,t _ - ,L . . - On-Site Water and Wastewater Progr-• i►'�`.� ,;;, '-. IAA 1- i , (907) 343-7904 ` SAFETY JUL 162.°1 1" Certificate of On-Site Systems A 4''t w ` A oval 051-582-47 g 020) 0201 '1 Parcel I.D. Expiration`i =:8 J� 1. GENERAL INFORMATION Complete legal description Thunderbird Heights #3A, Block 6, Lot 2 Location (site address) 24888 Teal Loop Chugiak, AK 99567 Current Property owner(s) Barry & Terri Schimmack Day phone • Mailing address 24888 Teal Loop Chugiak, AK 99567 Real Estate Agent Day phone 2. TYPE OF DWELLING: O Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: Four 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual 0 Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System 0 Public Sewer ❑ WaiverNariance request for: Distance: • Received by: l/, Qii'it1 I1'!i J Date: /up y the engineer,unless otherwise requested bythe engineer. COSA to be released to g q g COSA Fee $ 52-c Waiver Fee $ Date of Payment 1(418 Date of Payment Receipt Number 014115t' Receipt Number COSA# 03CI47 t 3'45 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Forge Engineering Phone (907) 522-7773 Address PO Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. Date 7/15/2018 j* 49 TH /\ *��/ 6. DSD SIGNATURE e..- System System #1 Approved for / bedrooms . Michael E.Anderson System #2 Approved for bedrooms �fi,�T, .l 4381-E� � �,��� Disapproved iq,P.R.OFEssok\\\\....0... Conditional approval for bedrooms, with the following stipulations: car ANC6. OWS W ATE AGER o Wp,Roc'RPM P C._ •1.A,, By: fatteA � m �c��cv1 a Original Certificate Date: (J .90� G201 8 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: .:" •, ^, COSA Checklist X Nitrate AdvisSr�y."_ .. Septic System Advisory Arsenic Ad'isdry Well Flow Advisory Other • ' j`� r • COSA blue sheet s c If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: Thunderbird Heights #3A Block 6 Lot 2 Parcel ID:051-582-47 A. WELL DATA Well type Public Water If A, B, or C provide PWSID# Well Log (Y/N) Date completed Sanitary seal (Y/N) Wires properly protected (Y/N) Total depth ft. Cased to ft. Casing height(above ground) in. FROM WELL LOG AT INSPECTION Date of test Static water level ft. ft. Well production g.p.m. g.p.m. WATER SAMPLE RESULTS: Coliform colonies/100 mL Nitrate mg/L Arsenic ug/L Date of sample: Collected by: B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Date installed 02/18/2011 Tank size 1250gal. Number of Compartments 2 Cleanouts(Y/N) Y Foundation cleanout(Y/N) Y Depression over tank(Y/N) N High water alarm (Y/N) N Date of pumping 7/2/2018Pumper Alaska Quality Septic C. ABSORPTION FIELD DATA Date installed 10113 1512010 Soil rating (g.p.d./ft2 or ft2/bdrm) 1 .2 System type Shallow Trench Length 65 ft. Width 5 ft. Gravel below pipe 3 ft. Total depth 4 ft. Eff. absorption area 560 ft2 Monitoring tube Y Depression over field N Date of adequacy test 7/12/18 Results (Pass/Fail) Pass For 4 bedrooms Fluid depth in absorption field before test 0 in. Water added 609 gal. New depth 0 in. Elapsed Time: 0 Mia. Final Final fluid depth 0 in. Absorption rate >= 600 g p d N Any rejuvenation treatment(past 12 mo.) (Y/N &type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot On adjacent lots Absorption field on lot On adjacent lots Public sewer main Public sewer manhole/cleanout Sewer/septic service line Holding tank Animal containment areas Manure/animal excrete storage areas SEPTIC/HOLDING TANK ON LOT TO: Building foundation >1 0' Property line >5' Absorption field >5' Water main Water service line >10 Surface water >100 Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: '* >10' Property line Building foundation >10' Water main ' Water Service line 0 Surface water >100 Driveway, parking/vehicle storage >10' Curtain drain None Noted Wells on adjacent lots >100' F. COMMENTS *See Lot Line Waiver OSP101105. G. ENGINEER'S CERTIFICATION OF A/ 4 -r �A • sly I certify that / have determined through field inspections and -C '•• 4A--'11-e0 • ,1- review of Municipal records that the above systems are in r: • '9 / * • 4'9TH �\ ..*�r conformance with MOA COSA guidelines in effect on this date. r Engineer's Printed Name Michael E. Anderson, P.E. Date 7/15/2018 �FA �,••Michael E.Anderson •:� . 4381-E .• (4,•-•,4%- % ' �k %ROFESSI��'� COSA brown sheet 10-10-12.doc 3 •0 601 (' \ r `N ,.. TArt / t \ . . v A / .t. c_ 0. v0 / o° . f ". , q , A / • • • 47„ r I5 / i , W �O �p cc:P 0 G o o i ! i ` D1 0 ,. 9 66br .tl, , ,i, (X 1/11 11 • 1 ASBUILT—NO CORNERS SET THIS DATE. SEWARD & ASSOCIATES LAND SURVEYING 688-4566 I HEREBY CERTIFY THAT I HAVE SURVEYED THE SCALE: FOLLOWING DESCRIBED PROPERTY: yo . .0-4-•-s .; •,;,�OF A�) yi=� -'1 -0�;� /.‹.4.f .",. )--'� - -e,i;: '4.?c'-2e2--= DATE: �v���' .'��5• AND THAT NO ENCROACHMENTS EXIST EXCEPT AS INDICATED. IT IS THE RESPONSIBILITY OF THE / J ,,*7. • Li OWNER TO DETERMINE THE EXISTENCE OF ANY GRID: .; .�. .! %•.*.4 EASEMENTS, COVENANTS, OR RESTRICTIONS : ..�/,..'6 ii WHICH DO NOT APPEAR ON THE RECORDED SUBDI— 4'' � "$ �t VISION PLAT. UNDER NO CIRCUMSTANCES SHOULD FB: • ora LS-WS Merk sewa ANY DATA HEREON BE USED FOR CONSTRUCTION r% '�/' Q OF FENCE LINES, OR FOR ESTABLISHING BOUND- �� � ''�� � � ARY LINES. DRAWN ��Fh �zfa1�±,'" MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING 1. GENERAL INFORMATION Complete legal description Location (site address or directions) Property owner Mailing address Lending agency Mailing address Agent ~'~/YlCr~ - Address Day phone Day phone Day phone Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: TYPE OF WATER SUPPLY: individual well Community well Public water NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. TYPE OF WASTEWATER DISPOSAL: individual on-site Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev. 1/91) Front MOA#21 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my inves_ti_gation and inspection, the on-site water sui~ply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. David R. Dayton P.E, Phone ~ ' ~/,,~. -;..~././'/7 Name of Firm Address Engineer's signature 20210 Donalar St. Chuglak, .~la~ka 99567 o DHHS SIGNATURE ~,, Approved for ~'z"~/~-~/ Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: Additional Comments The Municipality of Anchorage Department of Health and Human Services {DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The D HHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72~)25(Rev. 1/91) Bsck MOA#21 Municipality of Anchorage /~ Department of Health and Human Services HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: A. Well Data Well type Log present (Y/N) Total depth Sanitary seal (Y/N) 7_~ ~p~,-- (~ Parcel I.D. ~ ~ / -- ~- If A, B, or C, attach ADEC letter. ADEC water system number Date completed Driller Cased to Casing height Wires properly protected (Y/N) FROM WELL LOG Date of test Static water level Well flow Pump level1 SEPARATION DISTANCES FROM WELL TO: Septic/holding tank on lot Absorption field on lot Public sewer main g.p.m. ATINSPECTION ; On adjacent lots ; On adjacent lots Public sewer manhole/cleanout Sewer service line Petroleum tank WATER SAMPLE RESULTS: Coliform Nitrate Other bacteria Date of sample: Collected by: B. SEPTIC/HOLDING TANK DATA Date installed ¢/ Cleanouts (Y/N) Tank size Foundation cleanout (Y/N) Compartments High water alarm (Y/N) Date of pumping SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: On adjacent lots Absorption field ~/ . Depression (Y/N) Alarm tested (Y/N) / Pumper ~A~~ -- Well(s) on lot '~,,/,~ To property line Surface water/drainage Foundation Water main/service line 72-026 (3/93)* Front CONTINUED ON BACK PAGE C. LIFT STATION Date installed Size in gallons Vent (Y/N) High water alarm level /,2/4 "Pump on" level at Manufacturer Manhole/Access (Y/N) "Pump off" Level at Cycles tested Meets MOA electrical codes (Y/N) SEPARATION DISTANCE FROM LIFT STATION TO: Well on lot On adjacent lots D. ABSORPTION FIELD DATA Date installed ¢/ ~/ff ~ Length ¢~ Width Total absorption area Date of adequacy test '~//~./¢'~; Water level in absorption field before test Peroxide treatment (past 12 months) (Y/N) SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Sudaoe water Soil rating (GPD/FF) /'5"~ -¢~./'Z'~/~ System type Gravel thickness (~// Total depth '~, Cleanout present (Y/N) ¥ Depression over field (Y/N) Results (pass/fail) /¢~,/~-¢~ for '¢- Bedrooms ~ ~ ~.Crc After test /J Well oil lot '"~///~-/ / To building foundation On adjacent lots ~ '~-~- Surface water / ~-O Curtain drain E, ENGINEER'S CERTIFICATION If yes. give date On adjacent lots .~,/% Properly line ~. / To existing or abandoned system on lot Cutbank /L,)¢,',~'z~ Water main/service line Driveway. parking/vehicle storage area I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in David R, Dayton P,E, 20210 DonaJar St, Chugiak, Alaska Signature Engineer's Name , HAA Fee $ Date of Payment Receipt Number 72-026 (3/93)* Back Waiver Fee $ Date of Payment Receipt Number D¢lvid R. Dayton NO. 2205-E MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING GENERAL INFORMATION Complete legal description Lot 2; Block 6; Thunderbird H~ights #3A Location (site address or directions) 24888 (104) T~. Loop = Property owner Mailing address. Lending agency Gordon & Rita S~hmidt Day phone 24888 T~l Ln~p Chugiak~ Alaska 99567 Day phone 688-4545 Mailing address Agent Th6a RE/MAX PROPERTIES, INC. 2600 Cordova Str6et Address Suite, # 100 Anchorage, Alaska 99503 Unless otherw~erequeste~ HAA will be held forpickup. Day phone 257-0125 NUMBER OF BEDROOMS: TYPE OF WATER SUPPLY: Individual well Community well Public water NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer NOTE: If community wastewater system; provide written confirmation from State ADEC attesting to the legality and status of system. 72-025(Rev, I/91) Front MOA#21 s~.uowwqo leUOF!.!pp¥ .u +~ , ,.. :suogelnd!js 15U!MOIIOt eqj qi!M 'swooJpeq 'swooJpoq Jot I'~AoJdde ~uo!l!puo0 'peAoJddes!C JOJ peAoJdd¥ ~ . gI:InJ.VNOIS SHHQ '9 eJn~euB!s s,Jeou!Ou3 sseJppv ~NI~a~NI~N] ~ ~ ~ 'uo!loedsu! s!q~ ~o elep aq) uo ~oo~e uI suo!leln~eJ pue 'seoueu!pJo 'sepoa e~S pug I~d!o!un~ I1~ q]l~ eaU~lld~oo u! s! ~e3s~ lesods!p ~e3e~e~s~ ~o/pu~ ~lddns ~e~ e~!s-uo eq~ 'uo!~oadsu, pu~ uo!~8!~seAu! ~ ~o~j pu~ Sel!j eO~Joqauv jo ~!l~d!o!un~ eq3 ~oJj peu!~3qo uo!~ojul eq3 uo pas~q 3~q~ ~jpaA~eq~n;'l 'u!e~eq pe3~o!pu! eJmon~s jo ed~l pue s~oo~peq Jo ~eq~nu eq3 ~oj e~nbep~ pu~ I~UO!~ounJ 'ej~s s! ~els~s I~sods!p ~e3~e~s~ ~o/pu~ ~lddns Je3~ e~!s-uo eq3 3eq~ s~oqs uo!3~o!ldd~ I~Ao~ddv ~3poq3nv q31~eH s!q~ jo uo!~e8!3seAu! A~ ~eql ~!JOA I 'MOleq UMOqS e~p Uog~p!I~A eq~ jo s~ pu~ o~eJeq pex!J~ leOS A~ ~q pe!j!~eo sV ~=I:iNIDN=I Aa NOI.LO=IdSNI =lO .LN~ilN:~J.VJ.S 'g Municipality of Anchorage Department of Health & Human Services HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description:~''¢ ~-' I'~,V._.l~ "~'~O~o~.,15~/z-r'~ ~5 Parcel I.D. A. WELL DATA Well type /~ IfA, B, orC, attach ADEC letter. ADEC water sYstem number ~.11 I~'~, Log present(Y/N) Date completed Driller Total depth Cased to Casing height Sanitary seal (Y/N) Date of test Static water level Well flow FROM WELL LOG Wires properly protected (Y/N) AT INSPECTI MuNtCtpALITY Of ANCHOP-AGE ON.,.~.~ AL sERviCES DtVISIOt~ g.p.m. Pump level SEPARATION DISTANCES FROM WELL TO: Septic/holding tank on lot 'Z-~ ~ 4- Absorption field on lot ?...,~ o '~' ; On adjacent lots ; On adjacent lots. Public sewer main Public sewer manhole/cleanout Sewer service line Petroleum tank WATER SAMPLE RESULTS: Coliform Nitrate Other bacteria Date of sample: Collected by: B. SEPTIC/HOLDING TANK DATA Date installed °t "~ Cleanouts ~N) y High water alarm (Y~) Date of pumping Tank size ~.~'~b /~,~"1.~ Compartments Foundation cleanout (~N) ,,// Depression (Y/~ Alarm tested (Y/N) Pumper ..-2~ ~. Well(s) on lot ~,o~) To property line I o Surface water/drainage SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: On adjacent lots Absorption field '7 Foundation Water main/service line. 72-026 (Rev. 7/91) Front ~" " ' CONT NUED ON BACK PAGE C. LIFT STATION Date installed Size in gallons Vent (Y/N) __ "Pump on" level at High water alarm level Meets MOAelectric~ ~ ~NC E FRO M L' F~;~;~t 7c~; Manufacturer Manhole/Access (Y/N) ~ ---~'~ump off" level at ~cles tested Surface water D. ABSORPTION FIELD DATA Date installed o~ Length ~1 Width Total absorption area ~,'~ Depression over field (YL4"~ Result~fail) Peroxide treatment (past 12 months) (Y,~ Soil rating /~'(:::'~/~'¢- Gravel thickness ~.~' Cleanouts present ~N) Date of adequacy test for ,~0 ¢-.- (~) /-./~^/(¢ /~,,&/o ~'~" If yes, give date System type Total depth bedrooms SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Well on lot ~-~ ~ ~ ~ On adjacent lots ~J/A-' Property line To existing or abandoned system on lot Cutbank ,,-[' l ~,¢,* Water main/service line Driveway, parking/vehicle storage area .~'~ ' '+ To building foundation On adjacent lots Surface water Curtain drain 'U/~- E. ENGINEER'S CERTIFICATION I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. $ & S I~[NGINEEEING Signature 17034 Eagle River [.oep Eo~ No. 204 Engineer's Name Date ~--q ~ '?' : ..... ,^^ Fee $ Date of Payment .eee,ptNum er 72-026 (Rev. 3/91) B~ck MOA Waiver Fee: $ Date of Payment Receipt Number D. R. DAYTON, P.E., R.L.S. ~(~x~~(~(~ ChUgiak, Alaska 99567 20210 Donalar (so7) 696-2417 July 17, 1993 ADEQUACY TEST Legal Description: Lot 2, Block 6, Thunderbird Heights #3A Date of Test: July 16, 1993 Septic T~nk: 1250 gallon, 2 compartment, steel tank Absorption System: 24' x 40~ bed Soils Rating: 150 sq. ft. per bedroom Requirements: 4 BR - 600 gallons per day Test: Water was pumped into the absorption bed while measuring volume, time and rise in the liquid level in the bed. After pumping was stopped, the liquid level drop was measured at regular intervals. Results: There was no liquid in the bed before the test° 600 gallons of water were pumped into the bed with no rise in the bed. The system is currently functioning adequately for a 4 bedroom home. DEPT. OF ENVIRONMENTAL CONSERVATION : WALTER J. HICKEL, GOVERNOR ANCHORAGE DISTRICT OFFICE 800 E. DIMOND BLVD., SUITE 3-470 ANCHORAGE, ALASKA 99503 (907) 349-7755 March 11, 1992 FOR: S & S Engineering PWSID # 211156 My review of the records on file in this office reveals that the Eklutna Thunderbird Heights Subdivision, Class "A" Public Water System, is in compliance with the routine coliform bacteria sampling requirements listed in Table C, and with the inorganic sampling requirements listed in Table B of 18 AAC 80.200. Sincerely, Byron Roys Environmental Engineering Assistant BR/of MUNICIPALITY. OF ANCHORAGE DIVISION OF ENgIRONMENTAL HEALTH DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION APPLICATION FOR HEALTH AUTHORITY APPROVAL CERTIFICATE i. General Information ./ ApplicatiOn Date Z/f! /~6~ '(a) Legal Description (include lot, block,' subdivision, section, township, range) Location (address or directions) (b) Applicants NameG,.L~ ~k~,~ Telephone - Home Applicants Address Business (c) Applicant is (check one) Lending Institution Buyer~; 0ther~ (explain); (d) Lending Institution (e) Real Estate Co. & Agent Address Telephone (f) Mail the HAA to the following address: 2. Type of Residence Single-Family~ Number of Bedrooms 3. Water Supply Individual Well.'[ Multi-Family~-~ Other (describe) Community~ Publtc~-~ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Sewase Disposal, Onsite.~. Public~ Community~ Holding Tank~--~ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. [Page 1 of 2] 5. gn$ineerin$ Firm Frovidln$ Inspections~ Test% File Search, Data and Information. As certified by my seal affixed hereto and as of the validation date shown below, I verify that myinvestigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein.- I further verify that, based on the information obtained from the Mmnicipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wsstewater disposal system is in compliance with 8ll Municipal and State codes, ordinances, and regula- tions in effect on'the date of this inspection. Name of Firm (ENGINEER SEAL) Approved for.~.,k bedrooms Approved ~ Disapproved Terms of Conditional Approval Condi~al CAUTION THE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION (DHEP) ISSUES HEALTH AUTHORITY APPROVAL CERTIFICATES BASED SOLELY UPON THE REPRESENT- ATIONS GIVEN IN PARAGRAPH 5 ABOVE BY AN INDEPENDENT PROFESSIONAL ENGINEER REGISTERED IN T~ STATE OF ALASKA. THE DHEP DOES THIS A~ A COURTESY TO PURCHASERS OF HOMES AND THEIR LENDING INSTITUTIONS IN ORDER TO SATISFY CERTAIN FEDERAL AND STATE REQUIRE- MENTS. EMPLOYEES OF DREP DO NOT CONDUCT INSPECTIONS OR ANALYZE DATA BEFORE A CERTIFICATE IS ISSUED. THE MUNICIPALITY OF ANCHORAGE IS NOT RESPONSIBLE FOR ERRORS OR OMISSIONS IN THE PROFESSIONAL ENGINEER'S WORK. (DHEP SEAL) RRd/eJ/D18 [Page 2 of 2] 7-19-84 DEPT. OF ENVIRONMENTAL CONSERVATION ANCHORAGE/WESTERN DISTRICT OFFICE 437 "E" STREET, SUITE 303 ANCHORAGE, ALASKA g9501 BILL SHEFFIELD, GOVERNOR Telephone: (~07) Address: 274-2533 To Whom it May Concern: According to records on file in this office the Water Regulations Water System is in compliance with the State Drinking Si ncerely, MUN, ICIPALi.~ OF "~ ~OTEC~IO~ RECEIVED APPLI~'~"~IT FILLS OUT UPPER HAl.. 'ONLY Phone Property Owner T & D Construction Mailing Address Rnw ~'~?f*_ Pm. IneT'. AW ZipCode 99645 745--273i Buyer Gordon Schmidt Address 9430 Kylie Cir Anchorage zip Code 99502 Lendi,g restitution Alaska Pacific Mortgage Corn pany Pho,e 276-3110 Address Northern Lights zip Code ~X~ Realty Co. & Agent william Schleg~l Phone Totem Realty, Inc. Address 724. 15th Avenue Anmhroage zip Cede 99501 272-0571 Legal Description Lot 2, Block 6 Thunderbird Heights Street Locatio~ Raveu~iew Loop Type of Residence [] Multipie Family NO. of Bedroor~s 4 [] Other E~ Individual ~,<~ ~(.~,~ '~), ~ ATTACH WELL LOG; A well log is required for all wells drilled since June 1975. [~ Community ~'-'~ ~/~ ~ For weils drilled prior to that date, give well depth (attach log if available). Sewer Disposal ~ Individual Year Individual Installed: 1983 [] Public Utility When Connected to Public Utility: E] Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQOEST BEFORE PROCESSING CAN BE INITIATED, Time Time Time Time Date Date Date Date Inspector Inspector Inspector Inspector Field Notes: C'~ ~ ~, (-~ ' ~UNIClPALI~Y O~ k. ~f~J SC~.~' DEPT. OF H~i',LTH C ENVIRONMENTAL PROTEC[[ON NOV ~ 6" RECEIVED (~) APPROVED BEDrOOm8 *GONDITION8 OF APPROVAL ( ) DISAPPROVED ( ) CONOmONALAPP~OVAL' Well Log Received Well To ~sorption Soils Rating Date ~wer Installed~ 72.023(3/~) WELL DATA Well Classification ~' "~ Well Log Present (Y/N) Total Depth Cased to Static Water Level MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 264-4720 Legal DescriPtion:. ~4::~1~ ~. ~(0~ ~" Casing Height Above Ground Electrical Wiring in Conduit (Y/N) Separation Distances from Well: To Septic/Holding Tank on Lot To Nearest Edge of Absorption Field on Lot To Nearest Public Sewer Line Cleanout/Manhole Water Sample Collected by Water Sample Test Results Comments ff A, B, C, D.E.C. Approved (Y/N) Date Completed Yield Depth of Grouting Pump Set At Sanitary Seal on Casing (Y/N) Depression Around Wellhead (Y/N) ; On Adjoining Lots ; On Adjoining Lots To Nearest Public Sewer To Nearest Sewer Service Line on .Lot ; Date PROTECTION ¢E!_V ED B. SEPTIC/HOLDING TANK DATA Date Installed Standpipes (Y/N} Y Air-tight Caps (Y/N) Depression ever Tank (Y/N) Pumping/Maintenance Contract on File (Y/N) Holding Tank High-Water Alarm (Y/N) Separation Distances from Septic/Holding Tank: To Water-Supply Well ~, To Properly Line ~ To Water Main/Service Line ~ Size I P-.,..r~'o[ No. of Compaltments Foundation Cleanout (Y/N) Date Last Pumped ; for Temporary Holding Tank Permit (Y/N) To Building Foundation To Disposal Field ~, ,'O To Stream, Pond, Lake, or Major Drainage Course Comments Page 1 of 2 72-026(11/84) C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata Date Installed Width of Field Length of Field Depth of Field Gravel Bed Thickness Square Feet of Absorption Area Depression over Field (Y/N) Results of Last Adequacy Test Separation Distance from Absorption Field: To Water-Supply Well To Building Foundation ~ gO Lot _ J~, To Water Main/Service Line ~ To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area CommentsF'_ A~o",,C~Op ~e',=¢¢ Type of System Design Standpipe¢ Present (Y/N) Date of Last Adequacy Test To Property Line I,~ To Existing or Abandoned System on On Adjoining Lots ~ ,~O ' To Cutbank (if present) to ' D. LIFT STATION N, Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Electrical Codes (Y/N) Dimensions Manhole/Access (Y/N) "Pump Off" Level at Vent (Y/N) Pumping Cycles during Adequacy Test. Meets MOA Comments ** Check Permitted Bedroom Rating Against HAA Request ** I certify that I have checked, verified, or conformed to all MOA and HAA g uideli nes in effect on the date of this inspection. Company Flc~'~re~n re( ~ MOA No. ~' ~ Receipt No. ~!~ L