Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
TIMBERLINE LT 8
Tom Fink, Mayor unicipality of Anchorage Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 September 9, 1993 Delia Foley 2515 Telequana Drive Anchorage, Alaska 99517 Subject: Lot 8 Timberline Subdivision Permit %SW920273, PID %015-164-18 The subject permit, issued September 9, 1992 by this office single family well and/or on-site wastewater system, has expired as of September 9, 1993. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. If you have drilled the well, a well log must be sent to this office for documentation of the installation and to close the permit. If a licensed Professional Engineer has inspected the installation of the on-site wastewater system, the original as-built inspection report must be sent to this office for review, approval and documentation. All inspection reports must be submitted within 30 days of construction completion. When applying for a new permit, the fees are: $320.00 for an on-site wastewater permit; $120.00 for a well permit and $440.00 for a combined On-site wastewater and well permit. If you have any questions, ]yrog~ar9, ~lana.gez ~On-site Services for a please call this office at 343-4744. enc: Copy of.Permit cc: Flattop Technical Services MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 PAGE i OF ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW920273 DESIGN ENGINEER:FLATTOP TECHNICAL SERVICES OWNER NAME:FOLEY CELIA & OWNER ADDRESS:10831 TRAILS END RD ANCHORAGE, ALASKA 99516 DATE ISSUED: 9/09/92 EXPIRATION DATE: 9/09/93 PARCEL ID:01516418 LEGAL DESCRIPTION: TIMBERLINE LT 8 LOT SIZE: 66997 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: 4 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: DATE: DATE: THEODORE F. MOORE, P.E. PH: (907) 345-1355 TECHNICAL:SE 14530 ECHO ST. August 26, 1992 ANCHORAGE, ALASKA 99516 M.O.A. DHHS P.O. Box 19-6650 Anchorage, AK 99519 Dear Sirs: The purpose of this letter is to provide the required design narrative in support of our application for a permit to construct wastewater disposal facilities on Lot 8 of Timberline S/D, located at 10831 Trails End Road. Soils logs, perc test results, a site plan, design drawings and specifications are enclosed for your review. The proposed system will be constructed between test holes #4 and #5. As can be seen from the soil log, the native material between 2.5' and bedrock at 6' is a gravelly somewhat silty sand with a measuied perc rate of less than 1 minute per inch. The rapid perc rate coupled with the shallow bedrock mandates that 2.5 feet of filter sand be used to bring the bottom of the bed up to the present ground level. Using the soil application rate of 0.7 gpd/sq, ft. specified in the wastewater ordinance for filter sand, this 4 bedroom residence requires a total absorption area of (4 x 150)/0.7 = 857 square feet. The proposed 15' wide by 58' long soil absorption bed design has a total absorption area of 870 square feet. The topography in the vicinity of the proposed construction site slo?,es to the west at 5% - 10%. As discussed with Dan Roth during our 8/11/92 field inspection, there is a 4 high cutbank located approximately 15' west of the northwest corner of the proposed bed which will necessitate issuance of a waiver of the normally requh'ed 50' setback. The enclosed letter to Dan Roth confmning our discussion sets forth the rationale for issuance of the waiver. The reason why the proposed bed has to be within 15' of the cutbank is to preserve room for a future replacement site in the same general area. The proposed 1500 gallon STEP tank will be located in the vicinity of the present.soil absorption trench outside the 100 foot protective radius of the well serving tbis lot. As is also discussed in the enclosed letter confirming the site inspection with Dan Roth, we understand that the intermittent drainage course shown on the site plan does not constitute surface water requiring 100' separation foden septic system components. The proposed projeci will have no impact on present or future water supply and wastewater disposal systems serving adjacent properties, nor will it have any impact on reserved space/surface and subsurface, or on drainage. Please give me a call at 345-1355 if you have any questions on this submittal. Sincerely, Ted Moore, P.E. CIVIL & ENVIRONMENTAL ENGINEERING * ENERGY CONSERVATION & ANALYSIS THEODORE F. MOORE, P.E. 14530 ECHO ST. PH: (907) 345-1355 August 26, 1992 ANCHORAGE, ALASKA 99516 Dan Roth M.O.A. DHHS P.O. Box 196650 Anchorage, AK 995 !9 Dear Mr. Roth: On August 11, 1992 you and I met on Lot 8 of Timberline S/D at 10831 Trails End Road to determine the status of the "intermittent drainage course" on that lot, insofar as it affects the proposed upgrade of the wastewater disposal system. The site Plan in the attached upgrade permit application identifies the locations of the pertinent features. At the time of our site inspection (as was also the case on earlier inspections conducted by FrS) intermittent puddles of water were observable in low spots of the drainage course in question, hut there was no continuous flow path visible on the surface of the ground. You stated that DHHS would not interpret this as surface water requiting a 100 foot setback from septic system components. If continuous surface flow were to occur in this drainage swale at some future time, then it would be necessary to either relocate the drainage course (being careful to not let it impact wastewater disposal systems on adjacent lots) or install a culvert to contain the flow. We also looked at a Iow cutbank (approximately 4 feet high) beside the driveway Which will be 15 feet fi'om the closest part of the proposed soil absorption bed. You questioned whether effluent might daylight out of this bank after the system is in operation. I pointed out that om' soils logs for the test holes in that area indicated that a permeable gravelly sand extended down to bedrock at 6 feet, and said that in my opinion daylighting of effluent was unlikely because it could percolate through the permeable soils beneath the driveway. You indicated that DHHS should he able to issue a waiver of the normally required 50' setback from a cutbank in this case. Please let me know if the above is not a true representation of the DHHS position on these issues. cc: Bob Lohr and Celia Foley Sincerely, Ted Moore, P.E. LoT ~ }(A$i L OF HILLS EX[ST, $.T.-= .'P. TAN~ /eT WiTH LIFT STA I WEL~ LOT G HoU$~ TO BE 50~L ASs. SEt> I~ITHfN {00~' CouRSE, FlattSp Technical Services 14530 Echo Street ~nchorage, Alaska 99516 LoT 8 Tli,,1 BEE LIN E SITE PLAN NOTE,, THIS 15 NOT ALI. LocATfONg TA~K A 15' oF 5~r> ~ PLAN VIEM SCAL~: ),=/o, NAyW~ GRAV~LL~ SAND SECT/ON A-A S£AL~ ', J"= ~.~ ' Flattop Technical Services 14530 Echo Street Anchorage, Alaska 99516 LOT g TINBER LINE ~C/L SOIL ABSORPTION BED {>LAN /~N0 q_gosS-SECTION ScAI-~: AS NOTEb Flattop Technical Services 14530 Echo Street, Anchorage, AK99516 Phone (907) 345-1355 Lot 8 Timberline S/D 10831 Trails End Road Wastewater disposal system installation Specifications 1.0 General: 1.1 The scope of the project consists of abandonment of the existing septic tank and soil absorption trench and installation of a new 1500 gallon STEP tmrk which pumps effluent through a polyethylene pipe to a 15' wide by 58' long soil absorption bcd. 1.2 Construction shall be as depicted on the approved site plan and design drawings. Minor deviations from these drawings may be allowed or required by the engineer conducting the inspections. All construction procedures and material specifications shall confm~n with Municipal and State requirements. All sepm'ation distances shall be in conformance with Municipal requirements, miless specifically waived. 1.3 The contractoi: shall be responsible to obtain any necessary utility locates, and to work around any buried utilities. 1.4 The contractor shall provide adequate cover material and rough grading over all system components to ensure that proper drainage is aclfieved after settlement and that there are no residual depressions. Insofar as possible the contractor shall minimize damage to trees and existing lawn areas. 1.5 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading after the soil is compacted, as well as placement of topsoil and reseeding ail areas disturbed by the construction. 2.0 Septic Tank: 2.1 The existing septic tank is to be properly abandoned by pumping, removing or cutting out the top and backfilling with soil. 2.2 The new septic tank shall be Municipally approved 1500 gallon STEP tank with two compartments, and shall be set level on undisturbed soil. Each compartment shqll be equipped with a watertight manhole cover and a 4" cleanout. If the tank is buried less than 4 feet, it shall be insulated with 2 inches of approved burial type, rigid insulation. 2.3 All pipe connections to the tank shall be equipped with watexproof mechanical couplings. The waste line from the residence to the septic tank shall have a minimum slope of 1/4'" per foot, and the waste line between the tank and the soil absoq)tion system shall have a minimum slope of 1/8" per foot. A cleanout shall be installed within 5 feet of the building foundation, and a double cleanout shall be installed within 5 feet downs~eam of the septic tank. 3.0 Lift station: 3.1 The lift station mechanism shall be installed in the second compm'tment of the STEP tank. The lift station shall be an "Oreffco" package system as supplied by Anchorage Tank. The lift station compartment of the tank shall be equipped with a watertight manhole riser which extends above ground level. 3.2 The contractor shall be responsible to obtain the necessm3, Municipal eleCtric permit and inspection, and to provide a copy of the electrical inspector's report to the engineer overseeing the construction of the wastewater disposal system. 3.3 The on, off, and alarm floats shall be set at the elevations specified by the lift station supplier, and their proper operations shall be verified by the contractor. The high level alarm box shall be:m6unted inside the residence. 3.4 The discharge line from the lift station to the soil absorption bed shall be 1.25" diameter 160 psi HDPE pipe as supplied by Maskell-Robbins, or equal. An appropriate threaded adaptor shall be utilized to ' connect the HDPE into the lift station tank, and another appropriate adaptor used to transition to the 1.25" diameter Schedule 40 PVC distribution pipe in the soil absorption bed. 4.0 Soil absorption system: 4.1 The soil absorption system shall be constructed by stripping off the peat and reddish sandy loam strata from the designated construction site to expose the top of a gravelly sand stratum at a depth of approximately 2.5 feet below original ground. 4.2 The bottom of the excavation need not be level. Coarse sand complying with Municipal specifications for £dter sand shall be placed in the bottom of the excavation and compacted to create a level surface at the elevation of the original ground surface on the uphill side of the soil absorption bed. ' 4.3 A total of 9 inches of approved sewer gravel shall be placed on top of the filter sand with the 1.25" diameter Schedule 40 PVC distribution pipes laid level such that the pipe inverts are no less than 6 inches above the bottom of the sewer gravel. The.distribution laterals shall have 5/32" holes ch-ilied in the bottoms on 5' centers with the hole spacing staggered in adjacent rows. 4.4 Monitor tubes shall be of 4" diameter and installed in the locations shown on the design di'awings. The portion of the monitor tube extending through the sewer gravel shall be perforated. 4.5 Approved filter fabric shall be placed over the entire top surface of the sewer gravel. A ~ninimum of 2 feet of soil cover is to be placed over the filter fabric. If the soil cover thickness is less than 3 feet, two inches of rigid, burial type insulation is to be placed over the entire top surface of the gravel, in addition to the filter fabric. 4.6 The top surface of the cover material shall be raised a minimum of 6 inches higher than the surrounding terrain to allow for subsequent settlement, and shall be graded to smooth contom's. Fill slopes shall be no steeper than 3:1. 4.7 All area~s disturbed by the construction shall be covered with 4 inches of topsoil and seeded to promote rapid revegetation. This wurk shall be the responsibility of the owner. 5.0 Inspections: 5.1 A total of 5 engineering inspections will be required during the course of the project: (1) initial stakeout with the contractor to establish the location of the system and to discuss the plans, specifications and construction procedures, (2) after the native material has been excavated to expose the infiltrative surface to ensure that it is level and at the right elevation, and conforms with the soil test information, (3) after the sand leveling and/or filter material has been placed, (4) after the sewer gravel is in place and the distribution pipes have been laid and connected up to the septic tank, but prior to placement of insulation or filter fabric, and (5) after f'mal backfill and grading is complete. The septic tank requires one inspection after it is set level and the piping connected, but prior to backfill. This inspection may be incorporated with any of the above inspections. 5.2 The installer shall coordinate the timing of the inspections with the engineer sufficiently far in advance to ensure the availability of the engineer. 14530 Echo Sireet Anchoraae, A,l~ska 9951R Munlclp~lllty gl Anchorage - DEPARTMENT, OF HEALTH & HUMAN SERVICES 825 "L" Street. Anchorage Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR:.. BOB L©HR LEGAL DESCRIPTION: 1 2 3 4 6- 10- 11 12- SLOPE GP/Gi,,1 GRAY, SOt~E~H~T SILT'{, s~Nby GRAVEL pT CO~ IF YES. AT WHAT 16- 17- 20- Township, Range, Section: DEPTH? 7 ~&£~¢ Depth l0 Water Al[e:~,, (,/,~/~z Monitoring? 7 [~.~.Z, Dale:. Reading Date Gross Time SITE I~LAN Net Depth to Net ' ' Time . Water Drop COMMENTS _, T.~, PERFORMED BY:, AOOORDANOE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THiS DATE. 72-008 (Rev. 4/85) PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN __ FTAND FT ~I~,xALE , CERTIFY THAT THIS TEST WAS PERFORMED IN DATE; _..~/*~"/ ? ~ " 14530 Echo Sfreet AnChoracre, ~l~sk~ 9951g Munlclp~fliy ct ~ncnorage · DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG ~ PERCOLATION TEST ~.~Z PERFORMED FOR:,.. ~)B LC)HR LEGAL DESCRIPTION: LoT pT SM '~ Ebta 1St1 2 ML '~RA~ SILT 4- '14 15 16 17, SLOPE WAS GROUND WATER ENCOUNTERED? - ~0 IF YES, AT WHAT 12 - DEPTH? 19- 20- COMMENTS , , Oeplh (o Waler Alter Monliorlng? D~'~ Date: Township, Range, Section: SEC ~ T I'~ I~, K ~ ~ SIT~ 15LAN Reading Date Gross Time Net Time Depth to Water Net Drop PERCOLATION RATE TEST RUN BETWEEN -- (minutes/inch) PERC HOLE DIAMETER FTAND __. ~FT PERFORMED BY', ~I:I'A TT0~ TEc.~, ,~'b-'C._ ~ _ , ~""~_.._~'~._~. . CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ~/,~/~ ~ 72-008 (Rev, '4/85) ~: 14530 Echo Street Anchoracm, Alaska 9951R Munlclpllllty CT Anchorage ' DEPARTMENT. OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG ~ PERCOLATION TEsT 'T.H, PERFORMED FOR: J~C)B LEGAL DESCRIPTION: LOT ~ 4 6- · 7 8 9 11 16 17 · ' 18- 19- 20- LOHR TIF~R LHq£ FILL COMMENTS , pT' 4 ~i'5 ~g'DblSfl ~S ILT ~/' G~AV£L Township, Range, Section; SLOPE 5A~Y LoA~ WAS GROUND WATER ,Sec ~{ TI~N., 81TE ~LAN ENCOUNTERED? IF YES, AT WHAT DEPTH? Oeplh lo Water Alter Monllorlng? D P-.'{ gale: Reading Date +~ ~aL ~/tol~ PERCOLATION RATE TEST RUN BETWEEN Gross I ' Net Time Time Depth to Net Water Drop I;$2t/5 ICJ 1; Eg: 15' 2, · (minutes/inch) PERC HOLE DIAMETER FT AND /~' FI ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. 72-008 (Rev. ·4/85) CERTIFy THAT THIS TEST WAS PERFORMED IN DATE: <:~/~"/e ~ PERFORMED FOR= LEGAL DESCRIPTION; LoT ~ ~T 1 2, 3 SP/s~ · 7 12 ,'i4; 15.~ 16- 17 18 · 1,t530 ~.cho Street ~[nchorag. e Alaska 99516 Munlclpa lt¥ ot Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage. Alaska 99502-0550 SOILS LOG -- PERCOLATION TEST T.H. ~q LoHR DATE PERFORMED:., Township, Range, Section: SEC ~q , TI2 SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED7 IF YES, AT WHAT DEPTH? $ L 19 Oeplh (o Waler Alter Monitoring? D~' Dale: Reading Date Net Depth to Time Time Water 2;$'7: qo 25' 2'. S~: oD Drop PERCO[:ATION RATE ~ (minutes/inch) PERC HOLE DIAMETER , C~" ' · TEST RUN BETWEEN ~. ~' FT AND L~ ' FT PERFORMED BY: .. FLATTOP TECtl, ~VCF. m ~ ~ ACCORDANCE WITH ALL ST&TE AND MUNICIPAL GUiDELiNES IN EFFECT ON THIS DATE, 72-~8 (Rev.'4/~) CERTiFy THAT THIS TEST WAS PERFORMED IN F]dlt6~ Technics! Se'ffvic&s 14530 Echo Street AncSorc~g.e, AIc~skc~ g9518 Municipality of Anchorage DEPARTMEN'F OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST T.~. ~ PEREOR ED "OR,. LEGAL DESCRIPTION:, LoT ~ 2 3 4 5 ~.W, ~£bRock' 7- 9 10 11 LOHR 'l-l~ LI~ Township, Mange, Section: 16- ~ '18~ 20- · COMMENTS ,; ~OUTJ-{ ~Sbb~$f/ 5AHbY SLOPE WAS GROUND WATER ENCOUNTERED? SITE PLAN ~ " IF YES, AT WHAT DEPTH? Oeplh lo Waler Alter Meflltorl~g? 'DP-.¥ Date: Reading Cate Net Time Dept~ to Water Drop PERCOLATION RATE __ TEST RUN BETWEEN -- (minutes/inch) PERC HOLE DIAMETER .. FT AND , FT PERFORMED BY: _F-/ATTOP "r/~C//. ~WC'S".~ I . .'.~ ~ ACCORD~,NCE WITH ALL 8TA'Tt: AND MUNIOIPAL GUIDELINES IN EFFECT ON THIS DATE. 72-008 (Rev.'4/85) CERTiFy THAT THIS TEST WAS PERFORMED IN DATE: a/.~! ~ ~ ~.~,~ MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage.' Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT PHONE [] NEW MAILING ADDRESS LEGAL DESCRIPTION LOCATION ~n~ ~ ' '' DISTANCE TO: ]Well ~¢, ] Absorption area ~.~, Dwelling t~' PERMIT NO. ~<~= Manufacturer ~ ~ ~M Matorial ~ ~o. o, compa,tmants Well Dwelling PERMIT NO. ~ ~ ~ DISTANCE TO: O ~ Manufacturer Material Liquid capacity in gallons ~ Well Foundation Nearest lot line PERMIT NO. ~ ~ DISTANCE TO: ~ ~ ~ No. of b~es Length of each~1' Total length of lines Trench width Distance between lines <. ~ Type of crib Crib diameter Crib depth Total effective absorption area ~ ~ DISTANCE TO: Well ~ ~ ~ ~ Building foundatio~ ~ Nearest lot line ~0 ~ . . Class . Depth 5~, Driller Distance ,o lot I}~0, PERMIT NO. _ ~ DISTANCE TO; I ~ Sewer line Septic tank Absorption area(s) OTHER PIPE MATERIALS SOl L TEST RATING / ~ DATE - LEGAL 72-013 (Rev, ;/78) F'ERM ]]T NO. t')EPFffi?.TP!ENT C)F:' HEFil...'/"H RND E!',!V]iIi?.Ohff'IENTI::tI.. 2;~:9 14 COO!'( FIV. E;SU:i;Uig7 SQ!.II:;:tB:E FEET '['"?F:'E OF :FJOIL F!BSEIt;:E:TZOIq S"r'S'f'EM :IS: 'T'I:;::ENCH ["ll:::l::-:',):l'"l[.JPl NL.IhlE[E!:R O1:::' E:E::DF.'.OCI['~]'_'E; ~/2~ SOIL I:E'.F:I"I'.~P,IE~i ,::E~;Q F'T,.'"E:R; ..... :35 THE RIE(;)UiF?.E[) 'SIZE OF:' 'f'HE: SOIL F:IBE:OI:;d-:"F'ION S~,"S'!-EFI 'I"HE !.JENI}iT'H [) I MIL:iN."::: ;!: Ol",l I E~ "FHE L.E]'.,IGTH ,:: J: h!, FEE'f' ) !::if:: THE TI:;:'.ENC:H OR [:,1:;]:1:::i ]: N!::' :[ ELD. '['HE [':,EF"FH OF:' FI TRE:I",IC:H OR PIT [.:El THEE E)~fE:'I'F:I.t',ICE E:E'TI.,.![F:E{N THE '_:ii&II:,?.F'FIC:IE OF:' THE: I:~iF,~:i31..Jl'.,lt:) FIN[:, TI'IE E:OT"I'OI'"I OF THE: E??::CI::f,/'I:::I"FZON (]:['-,[ T!..IE!RE ]".SE; t~-,I[;:~ :"~;EZT' 1-,.C[[:q'H F'OI::~: 'f'F?.E:I',ICFIE'.E;. TIlE E!ff?.Ff,,,'EL. E:,EEf:'TH I Ei; THE:: FIIhlZfI'"IUP1 [:,EPTH OF C'iI:;.:Ff,/EL. BEI"I.,.IEE:I",I THE OUTF'FI[..[. FIN[) TI"tEE BOT]'CIM OF THE E',:':',C:Ff,/'FI'T'IEIN (!!"¢, FEE-F). I::'ERPI Z "1' F:II::'F'L. ]: CANT Hl::lf:; THE F;?.E'.E;PONfB X P I L. ]; 'I"'¢ 'TO [ i",!FOI:[:I'"I ]'H );N:!::;TFILL.FIT:EON .I'I"4:{;F'IEC:'FZO.t",!2~; OF I:':IN'T' I.,.IEL.L.:E; I::I[>J'FICE:I",IT 'TO 'TH]XE; F'ROPERI-'T' FIN[:' TI-IE I"~I. JP'IBEI:,~: OFr RE2;:[[:,E]",IC:E:E; THI::IT THE: P.IEL.L.I.,.K[LL SEI::?.',,,'E. E',F::IC:k:t::: ILL. I I",l(:!i EIF' FII",I"/ ::~;*'/51'E]'"I 141 'T'FIOI. JT' F .1; [qF[L ]:I",I:.'.-',PECT Z ON AND I':tF'F'F~:OVI:::IL. E¢¢ TH I S £)E;F'F!RTi'qE£NT IqZLL. E=E 51JE',J'E3]T ']'(] t'fi Z N ].' HUM [> ): ~STI:::!IqCE E:ETNEEN R ~-4EL..I.. FIND FIl",l"r' CII'4'-':E!; :[ 'T'E Ei;EI.,II::IEiE [:' ].' .'.-E;F'Er:'E;I::IL :E;"r':E;'TEI'"I I E; :!.E)E!I [:E:[E'/' F:OI?. ,":1 I::'RI',,"FIT'E t.'.IE.'[_L.~ 0[;?. J-59 TO .::.::EIEI FEE'F FF'::OM FI PUEiC..:[C I-'.IELL I)EPEI',![>]:NE4 UPON THE T"/F'E 01:: PL.II:ii~L.]:C !4EL.[ EITHEF4.' 1:4:EC!U]EF'~rEi'qENTE!; MFfT' RPPL¥. E;F:'EC.:f.F']ECF:ITZO[",I'.E; FIND CON'.;~['RUCT.I:C[I",I E)IF:IEff~:I::IM:!; I::~F?.E Ff,,,'FI:I:LFItEd_.E T'O IIqE;URE PROPEl::,: ENE;TF~LLFIT:[OI",I. F:'O!:;Ff'H liE:"," THE: I"IUi",I Z C Z PRE.. 1_' T'-," OF' I::INC:HORFIGE. 2: ]: bX!;I....[.. ZI',IS]'FI[J... 'f'HE E;"r":STEEI"! ZIq FiL-:CORE:'F:INCE 1.4ITH 'FHE COE:'E]E;. ]:: Z LII'~[)ER:!i;TFIN[:, 'I"I'IFIT 'THE: Of",I-L:~]:T'E '/.E;EP.IER %"r'STEfq I"IF:t'T' I:;?.EE:!UZI:;i:E E:NL.F:II:E'.[~f~:I"IENT CERT :[ F"!" THF:IT I I::ii'q FFIPI :[ [.. I FIR 14]:TH THE .F,.:EC!UIREi'qE?.,IT:i:: F'O[q: OI",I--E;.I]"I'E :iE;EZl,~!ER:::"; FIIqD 14EL. L:E; FIFE; :E;ET F:E:ii~ :i: [>ENCE :[ S )E:,EL.E[:, TO I1', JF¢'llE:E; :SCP'I[ :F'E':L E THFII",t :~: :!; ]: [:i!",lE [:,/I ' FIPF:'I_ :[ C:FIh ]: :.:];'.:.i;UE[:, L r .. THE YAMES Lo SCHEFFEL, PoE. 239 West Cook Avenue Anchorage, Alaska 99501 August 25, 1978 Municipality of Anchorage Dept. of Health and Environmental Protection Pouch 6-650 Anchorage, Alaska 99502 Subject: Soils Test / Lot 8 Timberline Subdivision Gentlemen: Attached is test hole data for the subject location. No ground water or bedrock was encountered. Based on the ~aterials and the two-bedroom house, a total absorption area of 190 sq. fro is required. If there are any questions, please contact meo /jss Sincerely, I. II I-[ ...... IIIqF L '"n:::F:l'l" l ON '.1 ..... ' [ ii ..... ':' ''"r' 3UE:''¢ SC'HEF'FE:L' XL:'J'--='': H' C:O01':~ I:::l"'"[!:; --I:'FEF OMFIL.LE;'T'"'''!'RFIIL'Z EI'"IE:' ..... LL:.: T I M~:: E'F'I 'r NE ':~ ,,'E' Lr '[ ...... ;' - J]:.l S¢..:!I. JF!I:;;:E: F:'EE:T ['11FiI ! I"IUH D I ZI"Fli",tE:L:. BETI.,.IEE[N FI HELL. FIi"~,E:, F!r.,Ih.' ON....'_=; ! TE ZEHFIGE: D I :E:iFIO':'SF:IL. 'J.:;'T'Z'I"E]"! I Z :L!EiEi FEET I'::'CIF~: Ft PRI',/FITE I,.IEL.L.~ OR: :!_50 TO 2el~Zl FEET F'!:.'OH FI F'UE:LIC NELL E:,EF'ENDING UF'Oh! THE "F'¢PE OF:' F'LIE:L. IC kiel..[ .... 14EI...L L. OCE5 FiRE I;::EQUIP. EE:, f:tND i"ILP:';-f' BE P. ETUF:'.NED TO THE: DEF'F:IP.'f'MEN'F' I.,.II-['HIN 2:1~:.~ C, FI"r'S OF THE I.'.IE:L.L C:OHPLETf'IOhl. CITHEF~'. F?EI::!U'[F~Ei'I1ENTE; MFl"r' f:IF:'PL'¢. SF'EC!FICFITIOI',!!; FIN[::' CONS'I"I?.IJC:T!ON I)IF:IGI:;;:F:Ii"I:i; F:IF;;:E FIVF!II._FIBLE 'TO INSLIF:'.E PR'OF'El:;?. INSTFILLFIT'IC~N. ! i:::ER'I":[F"r' 'Fl-If:IT i: I I:1i"1 FRHII_ZRR I.,.!I-I"H THE REQUIREMENT:;:i; F'OF'. ON-.~I'I'E SEI.qEF;:S f::lN[) HEL. LS RS SET FORTH B'¢ THE'.' MUNIE:IPRLI'T"¢ OF FINCHOP. FIGE. 2: I I.,.I:[LI_ INSTRLL 'T'HE :"5'CST'EM I['.,1 RC:COF.:DF:INCE P.II"FH 'THE CODE'.:.;. L .I. Jhl[_:.[.': ............ ::FifI,ly AUgUSt 1, 1978 James L. Scheffel 239 West ~ook Avenue Anchorage, AR~§ka SuSect: Lot 8 Timberline Subdivision Before this department maypprocess the request for sewer ~d water approval, several items will need to b~ completed. A one-hundred (100) foot separation bergen the well and the leaching area is required. Either your well or leaching area must be moved to comply with state and local health codes. The septic tank ~s fifty~six (56) feet from the well, which is satisfactory. If the well is moved the sewer system will need to be checked for adequacy. The firms in the Anchorage area who performed the test are attached with the letter. Before the test is performed, a four (4) inch olem%o?t m~st be installed to the seepage pi~. If the leaching area ls moved, a soil test will need to be obtained and prior to any constr~ction a permit must be obtained from this office. In the event the adequacy test performed on the existing system fails, an upgrade of the leaching area will be necessary. Prior to the upgrad$~a soils test must be obtained and a permit must be issued by this departmea/t. The septic tank must be pumped and the receipt should be made available to the office. The ~ell is presently ia a pit. The casing must be extended above gro~%d level and the pi~ filled with impervious type soil. Sincerely, Robert C. Pratt Sanitarian RCP/dea INSPECTION TIME TIME TIME 'INSPECTOR INSPECTOR INSPECTOR\~' ~UNICIPALI~ OF ANCHORAGE MUNICIPALITY OF ANCHORAGE DEPT. OF H~ALTH & ) ENVI RONMENTAL SANITATION DIVISION JU~ MAI LING ACDRESS PROPERTY RESIDENT (If different from above) PHONE 2. BUYER PHONE MAI LING AD DR ESS 3. LENDING INSTITUTION PHONE 4. REALTOR/AGENT /./~ I MAILING ADD~ESS 5. LEGAL DESCRIPTION STREET LOCATION 6. TYPE OF RESIDENCE NUMBER OF~BEDROOMS [] One [] Four [~SING LE FAMILY [~WO [] Five [] MULTIPLE FAMILY [] Three [] Six [] Other 7, WATER SUPPLY E~-~ NDIVIDUAL* * ATTACH WELL LOG. A well log is required for all wells drilled [] COMMUNITY since June 1975. For wells drilled prior to that date, give weir [] PUBLIC UTI LITY depth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM ~'~i'NDiviDUAL/ON_SiTE** /~7 ~' YEAR ON-SITE SYSTEM WAS INSTALLED. [] PUBLIC UTILITY NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010 (Rev, 6/79) ~ ] THIS SIDE FOR OFFICIAL USE ONLY 1, TYPE OF RESIDENCE NUMBER OF BEDROOMS [] SINGLE FAMILY [] ONE [] THREE [] FiVE [] OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2. WATER SUPPLY [] INDIVIDUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTILITY Connection Verified LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER E~INDIVIDUAL/ON -SITE DATE INSTALLED []PUBLIC UTILITY Connection Verified INSTALLER []Septic T~]~k or []Holding Tank Size: ~t.~ If Tank is homemade SOILS RATING give dimensions: TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4. DISTANCESwELL TO: Septic/Holding~ Tank Absorption(, c_"~Area Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line 5. COMMENTS (~APP ROV ED FOR ~-~-~ BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany certificate) []DISAPPROVED DATE BY 72-010 (Rev. 6/79) DEPARTMENT OF HEALTH & ~NVIRONMENTAL CTIbN~' ' · C,~, ~. : :: · ,'-)~ /EEEEEEEEEEEEEEEEE~ 825 L Street- AnchorVaJge, Alaska 99501 '; ~ Telephone 264-~20 ~~ ', } IRECTIONS: Complete ali parts on page 1. Incomplete requests will no~~ ~a~r pr~essi~ 1. PROPERTYOWNER MAILINGADDRESS /'~ J~ ~'.70 / PROPERTY RESIDENT (~fld~rent from above) PHONE F/~ 2. BUYER PHONE MAILING ADDRESS 3. LENDING INSTITUTION MAI LING ADDR ESS 4. REALTOR/AGENT ~]~ ,~/~ MAI LING ADDR ESS 5. LEGAL DESCRIPTION Lo-f- ~ ~ ~,m b~,.~-I;~ %~ ~o[~v;~;~-,-, STREET LOCATION NUMBER/OF BEDROOMS 6. TYPE OF RESIDENCE [] One [] Four [] Other__ J~ SINGLE FAMILY ~ Two [] Five [] MULTIPLE FAMILY [] Three [] Six ~d 7. WATER SUPPLY ~, INDIVIDUAL* *ATTACH WELL LOG. A well Icg is required for all wells drilled [] COMMUNITY since June 1975. For weUs drilled prior to that date, give well [] PUBLIC UTILITY depth (attach Icg if available.) ,~O / 8. SEWAGE DISPOSAL SYSTEM ]~ INDIVIDUAL/ON-SITE** **If individual/on-site, give installation date /~ If system is over two (2) years old an adequacy test is required [] PUBLIC UTILITY by this Department. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. · 72-010(3/78) THIS SIDE FOR OFFICIAL USE ONLY DATE RECEIVED INSPECTION APPOINTMENTS TIME TIME TIME DATE DATE DATE INSPECTOR I NSP ECTOR I NSP ECTOR DIRECTIONS: 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS [] SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2. WATER SUPPLY [] INDIVIDUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTI LITY Connection Verified LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER [~]INDIV~DUAL/ON -SITE DATE INSTALLED []PUBLIC UTILITY Connec~i0n Verified. INSTALLER [~Septic Tank or [~]Holding Tank Size: If Tank is homemade SOILS RATING give dimensions: TYPE OF TANK MANUFACTURER , TOTAL ABSORPTION AREA MATERIAL 4, DISTANCESwELL TO: Septic/Ho]ding Tank Absorption Area Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line [] CONDITIONAL APPROVAL (letter must accompany certificate} [~/DISAPPROVED DATE BY (Title) LEGAL DESCRIPTION 72-010 (Rev, 3/78)