On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP211440 PID Number: 015-164-16
Dwelling: ❑ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ❑ Upgrade
Name
C/O PARAGON PROPERTIES
ABSORPTION FIELD
❑ Deep Trench ❑ Wide Trench ❑ Bed ound
Site Address
11160 VOSIKOF PLACE ANCHORAGE, AK
EJ Other
Phone
Number of Bedrooms
Soil Rating
Total depth original grade
907-242-5287
3
GPD/SF
Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
Ft.
Gravel depth beneath pipe
Ft.
Subdivision Block Lot
TIMBERLINE; LOT 15
Fill added above original g
Ft.
Gravel length
Ft.
Township Range Section
Gravel width
Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION
DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total orption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
Fe
Ft.
Well
100,+
I
TANK 9 Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
GREER TANK
Capacity
1000 Gal.
Surface Water
50'+
Material
Number of compartments
Lot Line
5'+
NA
HDPE
2
Foundation 110'+
I
LIFT STATION
Manufacturer Capacity
Remarks OLD TANK DECOMMISSIONED PER UPC
Gal.
PER CONTRACTOR
Alarm location Electrical installed by
Installer
PIPE MATERIAL House to tank D3034 Tank to
drainfield D3034
A+ HOME SERVICES
Drainfield D3034/EXISTING CO/MTD3034
Inspector GEG AND MOA
BENCH MARK (Assumed elevation) 97.17 ft
Inspection 15` 12/8/2021 -
Location and description
2
3'd - 4t" _
TOP OF MANHOLE
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
00600 �
Conditional Approval: Date
........ ..............
(%E7� A.ess.
o
�� 9��o
Septic System X�Q�
Approved -�L` tet; Date
444�pr000��o�o
Note: this approval does not include well permit requirements.
#AEc
kmuv uuluLl ILS)
PERMIT NUMBER: PARCEL ID NUMBER:
OSP211440 RECORD DRAWING 015-164-16
A I B
MH 37.4 44.2
ST1 41.4 47.8
MH
42.5 48.6
DBL4 43.5 49.5
NOTE: PIPE LOCATIONS ARE SHOWN
PER GEG SHOTS TAKEN WITH LEICA
DISTO S910 LASER DISTANCE METER.
SWING -TIES TO HOUSE CORNERS
TIMBERLINE; LOT 14
/ RAISED DECK
WERE GENERATED IN AUTOCAD.
SURFACE WATER "PICKED UP" BY GEG ON 12/1/2021;
CREEK "DISSIPATES" AND COULD NOT BE "TRACKED" / �Do BRIDGE
THROUGH THE SNOW. HOWEVER, IT IS TRAVELING AWAY/ �F<
FROM THE SEPTIC TANK AND DRAINFIELD �q0
/ 7GS
PROTECTIVE BERM TO CREATE A 100'+ TRAVEL PATH
TO SURFACE WATERS -- SEE AS -BUILT SURVEY /
' PAVED
DRIVEWAY
EXISTING 3
EXISTING DRAINFIELD--\ BEDROOM
HOUSE
DBL1&2-
10' UTILITY EASEMENT
TRAILS END; BLOCK 1, LOT 4A
SHED
NEW 1000 GALLON \
HDPE GREER TANK
TRAILS END; BLOCK 1, LOT 6 & 7
N
SCALE:
v
1"=40'
I*.*****I%,%44
OF
*'0
...........T ...............�
.
r i
0..... ::...... ......... .
A A. Game s
E-7 2
LICENSE r,
#AECC884 `1�1•ilkIk /
ENGINEERING - SALES -, CONSULTING ..-:�, �.,_ :>..��•
3701 E. TUDOR ROAD, SUITE 101 'ANCHORAGE. AK 99507' PHONE (907) 337-6179' FAX (907) 33&3246' WEBSITE: www garnesseng,neenng com
PREPARED FOR:
PHONE NUMBER:
PAGE NUMBER:
C/O PARAGON PROPERTIES
907-242-5287
2 OF 3
LEGAL DESCRIPTION:
DRAWN BY:
TIMBERLINE; LOT 15
D.J.G.
TYPE OF WORK:
DATE:
�,_ SEPTIC TANK RECORD DRAWING
3/25/2022
N
SCALE:
v
1"=40'
I*.*****I%,%44
OF
*'0
...........T ...............�
.
r i
0..... ::...... ......... .
A A. Game s
E-7 2
LICENSE r,
#AECC884 `1�1•ilkIk /
PERMIT NUMBER: PARCEL ID NUMBER:
I OSP211440 RECORD DRAWING 015-164-16
TOP OF TANK AT INTLET = 94.65
INVERT OF BUNG AT INLET = 94.01
TOP OF MANHOLE = 97.17
FINAL GRADE = 97.0-97.09
NEW 1000 GALLON H.D.P.E. SEPTIC TANK
2" INSULATION PER CONTRACTOR
TOP OF TANK AT OUTLET = 94.64
INVERT OF BUNG AT OUTLET = 93.79
ENGNINEEM"INte-im GROUP%Ltd
ENGINEERING -- SALES o CONSULTING ,
3701 E. TUDOR ROAD. SUITE 101 'ANCHORAGE. AK99507- PHONE (907) 3374179* FAX (907)33&3246*MBVM.—.game ngneeiing.c
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
C/O PARAGON PROPERTIES INC. 907-242-5287 3 OF 3
LEGAL DESCRIPTION: DRAWN BY:
TIMBERLINE; LOT 15 D.J.G.
TYPE OF WORK: DATE:
�- SEPTIC TANK PROFILE 12/21/2021
... .........
4W
. . ......... ........... I...
#AECC884
ffrey A. Games Aff
—a
CE 7953 -Z;� a
?i 2- -2, coi AV
i I ...
...........
VOSIKOF PLACE
Scale 1" = 40' EDGE OF GRAVEL
('bad
1993
PROTECTIVE BERM
Lot 15
Timberline Subdivision
53,687 Sq. Ft. +/-
11160 Vosikof Place
3 Story Wood Frame House
With Attached 2 Car Garage
R
.,g•
C"
RAISED DECK
BRIDGE
CULVERT
CREEK
RET. WALL
3RD STORY
KICKOUT
2ND STOVY
WOOD DE PAVED
DRIVEWA Y
WOOD DECK
29.3
Cf)
12.0
ITS ( Q') 0sc
NOO 00' 00"E 20.00' 1
1a' VTIL I TY EA SEMEN T )
-------------------- ----------------------------
A r S890 53'08"W 330.08'
--f-T-m— i
—C".— — (M— OM— mss -ow— am— am— am— OW*— cm— cm— ow— Qw— am— om--j- om—
LOT 3 LOT 4A
I TRAILS END SUBDIVISION
M.
X Electric Meter c-0_) Telephone Pole 0 Concrete Bollard
A I/
T Tel. Pedestal Gas Meter Over Head Utilities
LIN
A
EElec. Pedestal ff-Cl Culvert Chain Link Fence
'S Septic
W1 Water Well
k,,,/) Septic Riser M.H.
.am
cieneral Notes
1. Excepting for gross negligence, the liability for this survey shall not
exceed the cost of preparing this survey. Dimensions to property lines
are plus/minus 0.1ft.
2. This document is created by Frontier Surveys for the purpose of An
as -built for Kristen Abegg, only.
3. This document is based on Plat No. 1974-113, Anchorage Recording
District.
-1.0 40.4 .8. 4
Cn
Fg------------------
_X .........
X X X
-N890 53'07"Lt 20.00'
NOO 01'23,�W 30.00'
T T
LOT 6
LOT 7 LOT 8
01
Disclaimer
1. This survey complies with the ASP
LS Mortgage Location Standards. The survey represents visible
irH 'of
improvements and conditions at the time of the survey. This document does not constitute a boundary �H
survey and is subject to any inaccuracies that a subsequent boundary survey may reveal. It is the ........
responsibility of the Owner to determine the existence of any easements, covenants, or restriction
which do no appear the record plat. Under no circumstances should this document be used for
construction or for establishing a boundary or fence line. PlerrM.S
gier
t.12
LS
210 40 8 1 0 3P/24/2022 IWA*
0,
Scale in Feet
ESSIM406
TRACT
AN AS -BUILT OF
LOT 15
TIMBERLINE SUBDIVISION
11160 VOSIKOF PLACE ANCHORAGE, AK
CONTAINING: 53,687 Sq. Ft. +/- (RECORD)
RECORD PLAT: 1974-113 ANCHORAGE RECORDING DISTRICT
PREPARED BY:
FRONTIER SURVEYS, LLC
650 W. 58th AVE. SUITE E, ANCHORAGE, AK 99518
907-460-1686
DRAWN BY: SS DATE: 12/22/2021 DRAWING ID: 21-910
CHECKED BY: PS SCALE: I"= 40' SHEET 1 of 1
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
pOBox 1m050 4700 Elmore Road
Anchorage, Alaska yeo19-so5o Phone: m* Fax: (yu7)u43-7yo7
Permit Number: OSP311440
Work Type: SepUcTankUpgmd*
Tax Code Number: 01518416000
Site Legal Address: TIMBERLINE LT 15 G:2641
Site Mailing Address: 1116OVOS|KDFPL, Anchorage
Owner: STEWARTCHARLES GRAHAM
Design Engineer: GARNESSENGINEERING GROUP LTD
This permit iofor the construction of:
[] Disposal Field RSeptic Tank [] Holding Tank [] Phvy
Effective Date:
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms
12/2/2021
12/2/2022
11 Private Well OWater Storage
All construction shall bainaccordance with:
1. The attached approved design.
2. All requirements specified inAnchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18/V\C72)and Drinking Water Regulations (18A\880)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65.Provide notification bycalling (QO7)343'7Q04(24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall boeither:
a. Opened and Closed onthe same day, or
b. Covered, sealed, and heated boprevent freezing
Special Provisions: The 1993 berm is required to be in place or rebuilt to ensure I 00'of travel for the effluent
prior to surface water.
Received By: _=�
Issued By:
Date: ( )— / :3) )_ /.
3
`k` A xt Tj OF
ANCHORAGE
` �� Phone.907-343-7904
Development Services Department �� �
On -Site Water G Wastewater Section Fax: 907-343-7997
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 015-164-16
Property owner(s) Paragon Properties, Inc.
Mailing address 11160 Vosikof Place *Anchorage, AK
Site address 11160 Vosikof Place *Anchorage, AK
Legal description (Sub'd., Block & Lot) Timberline; Lot 15
Legal description (Township, Range & Section)
Lot Size Sq. Ft. Number of Bedrooms 3
Day phone 907-242-5287
APPLICATION IS FOR: APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field ❑ Initial ❑
Single Family (SF) 0
(w/wo ADU)
Septic Tank 0 Upgrade M
(D) El
Holding Tank ❑ RenewalDuplex
❑
Multiple Dwellings ❑
Privy ❑
(SF and/or D)
Private Well ❑
Water Storage ❑
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that
this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: 4'Z?_G7 Waiver Fees:
Date of Payment: AZ I Date of Payment:
Receipt Number: _�252 726 Receipt Number:
Permit No. D_'-:� P 2 ) L LI Lfy Waiver No.
GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Clie nt FormsTermit Application.doc
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211440, Deb Wockenfuss, 12/02/21
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211440, Deb Wockenfuss, 12/02/21
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211440, Deb Wockenfuss, 12/02/21
i V PLACE
it
EDGE OF GRAVEL
Scale 1' 40'
KUM
wolm
NOO 00'00"E 20,00'
t� . t tt �`' �._
1(1 UTILITY' EASEMENT
— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —
A S890 53'08"W 330.08'
L J —ow— ow—cm— ow— ow— cm—ow— at— am— "—Ow— owl
:)am— ow— CM— DM— OW— QW— cm— 0"u— 0M ow—Q--,--- 0Om — OW — am — OW
LOT 3 1 LOT 4A
IGM0
Y,
Electric Meterc-0-3 Telephone Pole Concrete Bollard
A Over Head Utilities
T Tel. Pedestal Gas Meter
A
LES Elec. Pedestal Culvert Chain Link Fence
Septic
Lot 15
Timberline Subdivision
53,687 S. F. +/-
11160 Vosikof Place
3 Story Wood Frame House
With Attached 2 Car Garage
RAISED DECK,
BRIDGE
RQ CULVERT
CREEK
RET, WALL
3RD STORY
KICKOUT
PAVED
DRIVEWA Y
29.3
12,
Cn
r- 0
1.0 040.4 68.4
.3
CY)
SHr=[) c"� -------------------- *-
X -- X X --, X ---- X — X.
j"I- ftai-ftal- f"l- nw- 041- am- ow- am- CM- of
LOTLCAT7
TRAILS END SUBDIVISION
–N890 53'07'YE 20.00'
NOO 01'23"W 30.00'
OF At
luenera l Notes Disclaimer
1. This survey complies with the ASPLS Mortgage Location Standards. The survey represents visible
1 Excepting for gross negligence, the liability for this survey shall not
improvements and conditions at the time of the survey. This document does not constitute a boundary► H Z'
�0
exceed the cost of preparing this survey. Dimensions to property lines /-4
survey and is subject to any inaccuracies that a subsequent boundary survey may reveal. It is the
are plus/minus 0.1ft. responsibility of the Owner to determine the existence of any easements, covenants, or restriction
which do no appear on the record plat. Under no circumstances should this document be used for
2. This document is created by Frontier Surveys for the purpose of a plot ..... .... I
construction or for establishing a boundary or fence line. lPierr�m. --4ier 00
plan for Kristen Abegg, only. 00
00
3. This document is based on Plat No. 1974-113, Anchorage Recording 0 20 40 80 09/02/2021
St -
District. Z
fill
Scale in Feet PESSIONN-; S:1-
WINEMS
NOTM
#.%# I A P
TIMBERLINE SUBDIVISION
11160 VOSIKOF PLACE ANCHORAGE, AK
CONTAINING: 53,687 Sq. Ft. +/- (RECORD)
RECORD PLAT: 1974-113 ANCHORAGE RECORDING DISTRICT
PREPARED BY: i FRONTM
FRONTIER SURVEYS, LLC ul*vevs*
650 W. 58th AVE. SUITE E, ANCHORAGE, AK 99518
907-460-1686
DRAWN BY: SS DATE: 09/02/2021 DRAWING ID: 21-600
CHECKED BY: PS SCALE: 1" = 40' SHEET 1 of 1
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street- Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
NO. OF B~OOMS
~ Manufacturer ~~ ~ MateriS~ ,o, ofc?~ents
"~ Liq. capaz~ons IF HOMEMADE: inside length Width Liquid depth
~ ~ DISTANCE TO: Well Dwelling PER~IT NO.
O ~ ~ Manufacturer Material Liquid capacity in gallons
No. of lines ~inish grad~:n~ ~ne Total ,~f, ines ~inches Distance be~/:s
Total ef ctive ~sorption area
k~ Top of tile to Materla' beneath tile
~ Length ~th ' Depth '- PERMITNO~-
~ ~ Type of crib Crib diameter ., Crib depth Total effective absorption area
~ Well Building foundation Nearest lot line
~ DISTANCE TO:
~ Class Depth Driller Distance to lot line PERMIT NO.
~ Building foundation Sewer line Septic tank Absorption area(s)
~ DISTANCE TO:
OTHER
PIPE~ATEBIALS
INSTAL ER
72-013
DEFHRTfIENT C HERLTH RND EN',/IRONMENTRL ~ .OTEE:TION
':'": .... L" STREET., RNbHuRRuE., BK.
,=.64
~,,,-IEb b Ri"-~[:, Ei['-,~--"_.~ I 'Ti
_ ,--,OLdE, 2. c~
PERMIT Nn. ( '-' --~"-'
APPLICRNT CARL LUL. H::,INuER P. 0. E,U,,
LOCAT 1 ON ',,,'OS I EOF
LEGI=IL L 2.5 TIMBERLINE LOT _,I~.E
.
54888 =,&~IJRRE FEET
]'"r'F'E OF ,=-,OIL MB--,LRFTILN ~'r_,TEM TRENCH
, ' .:.L I L RRTINJ FT?BR)=
MR::--IIMUM NUflBEF.. ,OF E:ED, ROOMS=,-:-.~" '-] ' ' p (qLq_. ' "-'~
THE F.'E.] IRED' '- '~ OF '-' '- '' r. '-' '""
._ =,I,¢..E THE :,JIL RB_-,OF..FTIJN =,¢_-,TEM IS:
: : -'- -- 4'~
E:,EPTH= E L E t%~ L.~ FH
~--. E P T H =
THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRRINFIELD.
THE DEPTH OF R TRENCH OR PIT IS THE DISTRNCE BETWEEN THE SURFBCE OF ]'HE
GROUND BND THE BOTTOM OF THE E~CRVBTION (IN FEET).
THERE IS NO SET WIDTH FOR TRENCHES.
THE GRRVEL DEPTH IS THE MINIMUM DEPTH OF GRRVEL BETWEEN THE OUTFRLL PIPE
RND THE BOTTOM OF THE EXC:BVRTION (IN FEEl').
RE(~LIZRE[:, SEF'TZC: TRf4b:: SIZE~ '.{L~,~Z~ ISRLLOf-~S
F'ERMIT ttFFLI~.MNT HR-, THE RE=FuN_IE, ILITT TO INFORN THIS DEPRRTMENT [:,LRING THE
INSTRLLlaTION INsPECTILN.=, OF RN'.'r' HELL_, RD..TRCENT TO THIS PRAPERTY RND THE
NUflEER OF F..E_,IDENL. E_, THRT THE WELL HILL SERVE.
· R_.KFILLINu OF RNY _-,'r.=,TEM WITHOUT FINRL IN=,FEbTILN RND RPPROVRL BY THIS
DEF'RRTMENT WILL BE SUBJECT TO PRCSECLTION.
MINIMUM DISTFINCE BETWEEN R WELL 8ND RNY ON-SITE SEWRGE DISPOSRL SYSTEM IS
100 FEET FOR R PRIVRTE WELL OR 2.50 TO 200 FEET FROM 8 PUBLIC WELL DEPENDING
UPON THE TYPE OF PUBLIC WELL
MINIMUM DISTF~NCE FROM R PRIVRTE WELL TO 8 PRIVRTE SEWER LINE IS 25 FEET BND
TO R COMMUNI'FY SEWER LINE IS 7'5 FEET.
WELL LOGS RRE REQUIRED RND MUST 8E RETURNED TO THE DEPRRTMENT WITHIN ]:0 DRYS
OF THE WELL COMPLETION.
OTHER RE&]UIREMENTS MRY F~PPLY. SPECIFICRTIONS RND CONSTRUCTION DIBGRRMS RRE
RVRiLRBLE TO INSURE PROPER INSTRLLRTION.
F'EF-;r4 I T E:~:P ~ F-:ES [:,ECEf-~iBEF~ _-"3-2.,
I CERTIFY THRT~ ,
2.: I RN FRM.~L~R !~ITH THE REG~UIREMENTS FOR ON-SITE SEWERS RND WELLS RS SET
FCmRTH BY TH~ /~NIL. IPRLITY OF RNCHORRGE.
2: I WILL I/N~L THE SYSTEM IN RCCORDRNCE WITH THE bODES.
~:' I IINB, ER~T~:,~THFIT THE /N-SITE SEWER S'¢STE~ MR'T' REQ~IIRE ENLRRGEMENT IF THE
DOuGLAs A. STARK and ASSOCIATES. CONSULTANTS
957 Westbury Drive · Anchorage, Alaska 99503 * Phone: 277-4300
O¢:tober~ ~.~, i980
So il Te s:~-
D~t'~: o£' test~ October' 25, 1980: c>
Pareel~ Let 15,,~ Timberline ubdivxsxon~,, soutt~ end V, osikof Place
· Test. location,~ 10" north'~ 190" east of southwest: corner' of' 1'ot.,
Tes~c. me'thod~ al2? bac:khoe ~ole ~as" dug ~it~'a:shelf 6' down.
N~ groundwat'er was engountere~. ~ soul sample wag taken'at:
the~ 6~ leve~. ~eeause o£the desirah~'anature of the s'oi~,
a:per¢olatiom test was not?performeff.. THe' hole was'lef~ opem~
Att'achments~ lot map, soil gradat£om.'
Organization * Management * Engineering · Surveying * Plannin~a * Human Resource Development
PLACE
7
~4
At,,
1-~-4v- t4ot~
10.9.,.0.80
l! he~eb~"¢:erti'£y that I have surveyed L~t I5,
Timbe~I£ne Subdi~isi'on)~ ~nchorage, KIaska-
October' 20, i980
Location ....... ~?:. ..... (,.~. ..... :...,..Y~..(...~...~..~. ?,,~..~,.~ ..... ~./,~..: ..................................
/.)ate completed ....... ~...:.....],..:, ..... .,~,.~ ........................................................... i .........
Depth of well ......... ...,~.,..( .........................................................................................
~,ize of casing ...........................................................................................................
Distance to water .......~,0...( ...................................................................................
Di. stance to water while pumping .............. ~,~ .................................. at rate
of ................. -~..0~ .................... gallons per hour.
........... Formation
from
to
/0
DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On-Site Services Section E N
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744 APR' 03 1997
Parcel I.D. #
CERTIFICATE OF HEALTH AUTHORITY RECEIVED
APPROVAL FOR A SINGLE FAMILY DWELLING
1. GENERAL INFORMATION
Complete legal description
Location (site address or directions)
Day phone
Property owner
Mailing address
Lending agency
Mailing address
Agent
Address
Day phone ~-~'~
Day phone /"/~r-
Unless otherwise requested, HAA will be held for pickup.
NUMBER OF BEDROOMS: ~ \'
TYPE OF WATER SUPPLY:
Individual well ~'~
Community well
Public water
NOTE:
If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system.
TYPE OF WASTEWATER DISPOSAL:
Individual on-site
Holding tank
Community on-site
Public sewer
NOTE:
If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
79~025 (Rev. 1/91) Front MOA#21
5. STATEMENT OF INSPECTION BY ENGINEER.
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the dat~ this inspection.
Alaska Water &
Name of Firm w~t~water Services Phone
8471
Address
?
Engineer's signature Date /¢~///'~ '?
DHHS SIGNATURE
,~ Approved for
Disapproved.
edrooms.
Conditional approval for
bedrooms, with the following stipulations:
Additional Comments
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DH HS does this as a courtesy to purchasers of homes
and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineeCs work.
72~25(Re¥,1/91} Back MOA#21
Legal Description:
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVld~ C E i V E D
Environmental Services Division
825 L Street, Room 502 · Anchorage, Alaska 99501 · (907A1~{~3-434~97
...... Municipality of Anchorage
Health Authority Approval ~necKIml~%pt. Health & Human Services
~-o"r' {~"~ Tm~F-.~--c-m~E- ~/.0 ParcelI.D.: Ot~--/~4---J~
A. WELL DATA
V~ell type ~ gel-;,
Log present (Y/N) ~'~---~ Date completed
Total depth Cased to 4-0
Sanitary seal (Y/N) '~-~,~
IfA, B, or C, attach ADEC letter. ADEC water system number
Date of test
Static waLer level
Well production
WATER SAMPLE RESULTS:
Coliform
Date of sample:
Casing height (above ground)
Wires properly protected (Y/N).
B. SEPTIC/HOLDING TANK DATA
Date installed /~/~ O Tank size /O~3~:~ Number of Compartments ';~ Cleanouts (Y/N)
Foundation cleanout (Y/N) ~ . Depression (Y/N) ~O ~ High water alarm (Y/N)
Date of Pumping ~ Pumper ~+
C. ABSORPTION FIELD DATA
Date installed /o~O Soil rating ~or ff~/bdrm) /~ System type
Length ~ ~
Width _ ~ / Gravel thickness below pipe Total depth
Effective absorption area ~ f~ Monitoring Tube present ~/N) ~¢Depression over field (Y/N)
~Date of adequacy test ~/~/~ Results (Pass/~ail),~ For ~ bedrooms
/ ~ Flu,d depth in absorption field beforetest (in.); ~,, Imm~ely after' gal. water added(in.):
{ L Fluiddepth//~ (ins) Minutes later: /~ Absorption rate =_~4~O .g.p.d.
~ Peroxide treatment (past 12 months) (Y/N) po~ ~ If yes, give date
FROM WELL LOG AT INSPECTION
~-- g.p.m. ~' ~'~' ~ g.p.m.
Nitrate ~', ~ ¢~,v~/~. Other bacteria
Collected by:
D. L~ON
Manhole/Access (Y/N) __~ "Pump off" level at*
High water alar~ .~.~"- *Datum ~
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic/holding tank on lot /'.,O,'c~' f±
Absorption field on lot / ~'?~ ~
Public sewer main /'J IA-
I
~' IoO
Sewer/septic service line
On adjacent lots
On aOjacent lots
Public sewer manhole/cleanout
Lift station
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO:
Foundation ,~3 / '~'
-- Property line ~'_~/4- Absorption field
Water main/service line. ~lC'! Surface water/drainag~e (ciot- f~o/ Wells on adjacent lots
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line ~ '~/4-- Building foundation
Sudacewater~ '¢{'~,6I TD "7,~.[
Curtain drain I, Jo,'vE-
F. ENGINEER'S CERTIFICATION
Water main/service line
Driveway, parking/vehicle storage area
Wells on adjacent lots ~ I O O /
I certify that I have determined t~ field inspections and review of Municipal records
in conformance it OA 'A u defines in effect on this date.
Signature --
Engineer s Nam~ d~r~q/~ 4- ~:~.~$~
Date
are
HAA Fee $ '~.,~'¢~ ' ~
Date of Payment
72-026 (Rev, 3/96)*
Waiver Fee $
Date of Payment
Receipt Number
Water & Wastewatelr
April 2, 1997
8471 Brookrldge Drive ~ Anchorage ~ Alaska 99504
Phone (907) 337-6179 - Fax (907) 338-3246
Consulting Engineers
Municipality of Anchorage
Department of Health & Human Services
Division of Environmental Services
On-Site Services Section
P.O. Box 196650
Anchorage, Alaska 99519-6650
Subject: HAA for Private Well & Septic System. Lot 15, Timberline S/D.
To whom it may concern:
The subject lot has a 3 bedroom house on it which is served by a private well and septic SYstem.
The results of the field investigation and adequacy tests are summarized as follows:
A. WELL: On the day of my inspection (3/27/97) the static level was 34 feet below the top of
the casing. Water was pumped from the well at an average rate of 6.55 gpm for 100 minutes
(655 gallons). Throughout the pumping period, the water level remained at 37 feet (3 foot
drawdown). At the end of the pumping period the recovery was monitored for 10 minutes,
during which time it recovered completely. Based upon this data it was determined that the
capacity of the well exceeds the Municipal requirements for a 3 bedroom house (450 gallons per
day).
B: SEPTIC TANK: The existing septic tank was installed in October of 1980 (approx. 16.5
years old). According to the M.O.A records, it is 1000 gallons, has two compartments and is
made of steel. No warrantee is made regarding the future life of the septic tank.
C: DRAINFIELD: The drainfield is a single trench that is 3 feet wide, 39 feet long, and has an
effective depth of 5 feet. The elevation difference between the bottom of the sump, and the
cleanout invert (at the beginning of the trench) is only about 1.3 feet. In short, the sump does not
appear to go to the bottom of the drainrock.
Prior to beginning the adequacy test, it was noted that there was approximately 4 inches of
standing water in the clean-out at the beginning of the trench. It was assumed that there was a
blockage, and a pumper was contracted to jet clean the line. Bill McDonald (Old Mc,Donald, s
Pumping) indicated his jet line would not go any further than about 5 feet past the clean-out.
Based upon Mr. McDonald's findings, a contractor (Mike Blakeslee, A+ Home Services) was
retained to correct the problem. Mr. Blakeslee exposed the drainfield in the vicinity of the alleged
blockage, visually inspected the inside of the pipe, and determined there was no obstruction. He
did discover that the west end of the trench is about 4 inches lower than the portion of the
drainpipe that was exposed. This explains the surcharged condition observed in the eleanout.
Although this is not ideal (the drainpipe not level), given the fact that it has operated adequately
for almost 17 years, it is reasonable to assume that the future perforn~ance of the system will not
be impaired. It should be noted that the exposed drainrock looked very clean.
D. SEPTIC SYSTEM ADEQUACY TEST: Prior to beginning the test, the sump was dry.
Water was introduced into the cleanout and sump (alternated) at a rate of 6.55 gpm for a total of
100 minutes (655 gallons). The last 200 gallons of water rose the water level from 2.625 inches
to 5.375 inches (rise of 2.75 inches). This corresponds to 72.7 gallons/inch. During the first 15
minutes of the recovery period, the water level dropped 3.75 inches, indicating an absorption of
272 gallons. Based upon this data, it was determined that the absorption rate of the trench
exceeds 450 gallons per day, as required for a 3 bedroom house.
If you have any questions, please contact me at 337-6179, or on my digital pager at
1-800-481-1162. Thank you for your assistance.
Sincerely,
Jeffrty[ . Garness, P.E.,
M.S.
Principal
NOTE: The adequacy of a septic system is influenced by numerous factors, including, but not
limited to, seasonal surface water infiltration, groundwater variations, septic system
maintenance 05'equency of septic tank pumping, usage of biological additives), condition of
drain pipe and pipe joints (which can be damaged by seismic activi(v and deteriorate with age),
(ype of substances deposited in septic system (cigarette butts, sanitary napkins, misc. objects),
and the amount of water being introduced on a continual basis. Consequently, the results of this
adequacy test are only valid for the ,pecific day of the test. Furthermore, because of the limited
nature of this investigation, it is possible that there are hidden defects which may not have been
detected No warrantee is made regarding the fitture performance of this well or septic system
C.C. Bob & KT Tyler
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On-Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
Parcel I.D. #
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
GENERAL INFORMATION
Complete legal description
Lot 15 Timberline Subdivision
T12N R3W Sec 24
Location (site address or directions) 11160 VosJkof Place
Property owner Richard An,$huchz ~'~ ~ ~,C2.~'x IJ ~r ~ ~-~
Mailing address
Day phone--2~8-129~
Lending agency
Mailing address
Agent
Address
Day phone
Day phone
Unless otherwise requested, HAA will be held for pickup.
2. NUMBER OF BEDROOMS:
3. TYPE OF WATER SUPPLY:
NOTE:
Individual well x
Community well
Public water
If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system.
TYPE OF WASTEWATER DISPOSAL:
Individual on-site
Holding tank
Community on-site
Public sewer
NOTE:
x
If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72-025 (Rev, 1/91} Front MOA#21
STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage files and from my inves~i_gation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection.
Name of Firm
Address ,'~//
Engineer's signature ."?~ ~
DHHS SIGNATURE
~ Approved for ~ bedrooms.
Disapproved.
Conditional approval for
bedrooms, with the following stipulations:
Additional Comments
Date
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineer's work.
Municipality of Anchorage
Department of Health and Human Services
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: Lot 15 Timberline Subd:[vi~io~
A. Well Data
Well type Individual
Log present (Y/N) Yes
Total depth 40 '
Sanitary seal (Y/N)
Cased to
Parcel I.D. TI p~p~w ~r- 74
If A. B, or C, attach ADEC letter. ADEC water system number
Date completed 1/1,/R] Driller
,~n, Casing height
Wires properly protected (Y/N)
g.p.m.
FROM WELL LOG
Date of test 1/1/81
Static water level 30 o 3 '
Well flow 5
Pump level1
AT INSPECTION
5/18/93
29.R2'
8
18"
MUNIC!PALITY OF ANCHORAGE
ENVIRONMENTAL SERVICES DiViSION
; .'..Y 2 g 1993
g.p.m.
RECEIVED
SEPARATION DISTANCES FROM WELL TO:
Septic/holding tank on lot 125' ~-o S/P
Absorption field on lot 122' l:o S/?
Public sewer main N/A
Sewer service line N/A
WATER SAMPLE RESULTS:
Coliform 0
Date of sampte: 5/18/93
B, SEPTIC/HOLDING TANK DATA
Date installed 10/30/80 Tank size 1000
Cleanouts (Y/N) Y-es Foundation cleanout (Y/N)
High water alarm (Y/N) N/A
Date of pumping 5/18/93
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO:
Well(s) on lot 1].8' On adjacent lots 300 '+
To property line 20 '+ Absorption field 30 '+
Surface wateddrainage Drainage: 60' to 80'
; On adjacent lots 100' +
; On adjacent lots 100 ' +
Public sewer manhole/cleanout N/A
Petroleum tank N/A
Nitrate 3.28 reg./T, Other bacteria 0
Collected by: Davp Tc'c~t-Pr
Compartments 2
Yes Depression (Y/N)
Alarm tested (Y/N) N/A
Pumper Unknown
Foundation 23 '
Water main/service line N/A
CONTINUED ON BACK PAGE
72-026 (3/93)* Front
C. LIFT STATION
Date installed N/A
Size in gallons
Vent (Y/N)
High water alarm level
"Pump on" level at
Manufacturer
Manhole/Access (Y/N)
"Pump off" Level at
.Cycles tested
Meets MOA electrical codes (Y/N)
SEPARATION DISTANCE FROM LIFT STATION TO:
Well on lot On adjacent lots
D, ABSORPTION FIELD DATA
Date installed 10/30/80
Length 39' Width 3'
Total absorption area 375
Date of adequacy test 5/20/93 Results (pass/fail)
Water level in absorption field before test ri
Peroxide treatment (past 12 months) (Y/N) No
SEPARATION DISTANCE FROM ABSORPTION FIELD TO:
On adjacent lots
Surface water
Curtain drain
Well on lot 118 '
To building foundation 3R '
25~+
43.6 to 72'
Unknown
E. ENGINEER'S CERTIFICATION
Surface water
Soil rating (GPD/Ft2) ] 25 System type Trench
Gravel thickness 5' Total depth 8 '
Cleanout present (Y/N) Yes Depression over field (Y/N)
Pass for 3
After test
.If yes, give date
On adjacent lots 300 ' + Properly line ]5 '
To existing or abandoned system on lot
Cutbank N/A Water main/service line N/A
Driveway, parking/vehicle storage area gn ' +
I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect .~'~/¢~-'~d'~a~'o( this inspection.
Signature
Engineer's Name ~,'~/ ~ ~'~
Date %~ ~
Waiver Fee $
Date of Payment
Receipt Number
HAA Fee $ /7¢
Date of Payment
Receipt Number
No
Bedrooms
72-026 (3/93)* Back
it is the 'responsibility of the owner to determine
the existence of any easements, covenants, or re-
strictions which do not appear on'the recor&ed su
division plat. Under no circumstances should any
data hereon be used for construction or for estab-
ltshtog boundary or fence lines, l~e surveyor takes
responsib~lity'fo¥ the initial transacti'on onlY.
LOT /.5' BLOCK '~
SHOWN HI. EON.
Tom Fink,
Mayor
Department of Health and Human Services
825 "L" Street
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
May 28, 1993
Michael D. Travis, P. E.
RZA AGRA Alaska, Inc.
711 H Street, Suite 450
Anchorage, Alaska 99510-3442
Subject:
Waiver Request for Lot
Waiver Request
15 Timberline Subdivision
9WR930027, PID 9015-164-16, HA930261
Dear Mr. Travis:
Your request for a waiver(s) of the required 100 foot horizontal
separation of a septic system to the surface water has been
approved. The approved separation distance(s) ar~ the leachfield
to the surface water of 42 feet.
This waiver approval applies to the existing septic system to
surface water separation only. Any future upgrade to the septic
system will require all separation distances be met or another
approval from this department. Should the operation of the
subject wastewater disposal system cause any contamination or
degradation of the subject surface water, this waiver will
become void.
Sincerely,
Dan~el~. Roth
Civil Engineer
On-site Services
DR/ljm
~'~ MUNICIPALITY OF ANCHORAGE'~
Department of Health and Human Services
On-site Services Section
Waiver Review Worksheet
PID~ 105-164-16
WR9 WR930027
Date Received: May 21, 1993
Legal Description: Lot 15 Timberline Subdivision
Engineer: Michael D. Travis, P.E., RZA Agra Alaska,
711 H Street, Suite 450, Anchoraqe~
Applicant: Richard A. & Judy A. Anschuetz
Waiver Requested: Leachfield to surface water -
Permit
inc.
Alaska 99510-3442
42 feet
Criteria: 1. Geology: Points:
A. Water Table
B. Soil Sorption
C. Permeability
D. Water Table Gradient
E. Horizontal Separation
TOTAL:
2. Special Conditions:
3. Other:
Waiver is Granted: ~ Waiver
List Conditions or Reasons for above: D~
Rec ~: 24710
Amount: $ 590.00
RZA AGRA Alaska, Inc.
Engineering &Environrnental Services
May 10, 1993
711 'H' Street, Suite 450
Anchorage, Alaska 99501-3442
(907) 276-6480
FAX (907) 258-4128
31-1428
Dan Roth
Municipality of Anchorage
On-Site Services
811 "L" Street
Anchorage, Alaska 99501
Subject:
Dear Mr. Roth:
Request for Waiver
Anschuetz Property
Lot 15, Timberline Subdivision
Municipality of Anchorage
As mentioned in our previous discussions, a small, intermittent drainage traverses the subject property. The
drainage is within 100 feet of the existing septic system drainfield. The approximate location of the drainage
swale or stream with relation to the septic system and other improvements is shown on the attached sketch.
In our opinion, a waiver is not required because the drainage is intermittent. However, the owner is
presently contemplating sale of the property and because of timing, prefers to resolve any doubt at this time.
According to the microfiche records at the On-site Services Office, a 12-foot test boring was completed on
the property for the septic system design. The Icg of this boring indicates that the upper 3-4 feet of soils
consist of silty sand with gravel underlain by sandy gravel to the depth of the boring. The soils rating in the
absorption strata was 125, with the bottom of the system installed to 8-feet below grade. Unconfined ground
water was not observed in the test boring. The presence of the drainage was not indicated in the original
report (1980), or in the report dated 7/30/86 when the system passed an adequacy test. The bottom of the
leach field and the drainage are approximately the same elevation. The ground surface slopes toward the
drainage at approximately 10 degrees. At the closest point, the horizontal separation of the system and
seep is 42 feet. (See sketch.)
The site was visited again on Tuesday, the fourth of May, to take elevations and determine the source and
characterization of the drainage. Present flow in the drainage braids just beyond the Anschuetz property
and percolates into the ground. The flow does not appear to resurface in the immediate vicinity (checked
for approximate 300 yards down slope). The area was also traversed perpendicular to the drainage and was
not found to resurface. The area is dominantly alder vegetation. The water source consists of seeps and
a roadside drainage intercept upgradient from the Anschuetz property. One large seep contributes
approximately half of the stream volume and is about 300-yards from the subject property and just north
of the powerline. Approximate elevations taken with a hand level are shown on the area attached sketch.
To protect the drainage area from any potential impact associated with an overflowing drainfield event, we
propose constructing a small diversion dike between the system and drainage channel. The location of this
proposed diversion is shown on the attached sketch. The upslope terminus is above any area that could
~AGRA
Earth & Environmental Group
Municipality of Anchorage 31-1428
May 1993 Page 2
potentially be impacted by an overflow. The downslope terminus has a retention basin to capture any
overland flow. The design, incorporating an impervious liner, will provide a drainage break between the
system and drainage. A cross section of the dike is shown on the enclosed sketch.
We would appreciate your review of this matter, and if acceptable, issuance of a waiver. In the meantime,
if you have any questions, please contact us.
Sincerely,
RZA AGRA, Alaska, Inc.
Michael D. Travis, P.E.
Mey 10, 1993
~arth & Environmental Group
FAC$1PllLE TRANBHITTAL FO ,H
TOTAL ,'~ OF TRAN$t'. IlS5iONS (INCLUDING THIS PAGE): _~,
PART. (.-.- OF., ~
FA×~:
.... CONTACT NAME:
CONTACT~'
COMMENTS:
FROM:CHEMICAL AND GEOLOGICAL
LABORATORY OF AK.
A DIV. OF CT&E
5633"B"STREET
ANCHORAGE, AK 99518
/
PRELIMINARY: ~ FAX CHARGES:
FINAL REPORTS: BILLED ON INVOICE:
INVOICE TO FOLLOW
NO CHARGE
RZA AGRA Alaska, Inc.
Engineering & Environmental Services
711 'H' Street, Suite 450
Anchorage, Alaska 99501-3442
(907) 276-6480
FAX (907) 258-4128
May 26, 1993
31-1428
Dan Roth
MOA
On-Site Services
811 "L" Street
Anchorage, Alaska 99501
Subject:
Request for Waiver
Anschuetz Property
Lot 15, Timberline Subdivision
Dear Mr. Roth:
I inspected the leachfield improvements at the Anschuetz property. Dr. and Mrs. Anschuetz implemented
these modifications to fulfill your requirements for a waiver of the Health Authority Approval Guidelines. This
waiver is required because the absorption field is within the mandated 100-foot separation distance from a
surface drainage.
I enclosed as-built drainages of the new separation berm. This berm will stop any overland leachate from
the septic system from flowing into the drainage. The major difference from what we proposed in our May
10, 1993 letter is that no retention basin was constructed.
Because there is ample vegetation between the berm and the septic system, the lack of a basin will not
affect the performance of our design. The vegetation and berm will still allow the leachate to absorb into
the ground before reaching the drainage.
I believe the berm was adequately constructed. This modification will protect the quality of the area's
surface water. Please issue the waiver for this system.
Sincerely,
RZA AGRA Alaska, Inc.
Michael D. Travis, P.E.
Vice President
Enclosures:
As-builts
Waiver Application
Health Authority Approval Checklist
May 26, 1993
~AGRA
Earth & Environmental Group
rq
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
DIVISION OF ENVIRONIVlENTAL HEALTH
CERTIFICATE OF }NSPECTION FOR HEALTH AUTHORITY APPROVAL
OF ON-SITE SEWER AND WATER FACILITY
26~3-z~720
GENERAL INFORMATION
(a)
Legal Description (include lot, block, subdivision, section, township, range)
Location (address or directions)
(b) Applicant Name ~J~ ~OETE Telephone: Home ~' ~ ~O Business
(c) Applicant is (check one):'L~hding Institution ~; Owner/builder ~; Buyer ~; Other ~ (explain);
(d) Lending Institution" Telephone
Address ~ ~
TYPE OF RESIDENCE
Single-Family,J~ Multi-Family []
Number of Bedrooms
Other
· WATER SUPPLY
Individual Well ~ Community [] Public []
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status. ,.
SEWAGE DISPOSAL , ,
Onsite~ Public [] Community [] Holding Tank []
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status·
Page 1 of 2 72-025 {11/84)
ENGINEERING FIRM PROVIDIN~ ~NSPECTIONS, TESTS, FILE SEARCH, DA,~ AND INFORMATION
AS certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health
Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained
from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on
the date of this inspection.
Name of Firm /5~ ~..~ /_ i~,f ~..~ Telephone .~'/--,~-0 ~
Approved for ~ P (~, bedrooms by~7
Approved 74'.~ Disapprove/' Conditional
Terms of Conditional Approval
~ ' ¢~AUTION
The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority
Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional
engineer registered in the State of Alaska. The DHEp does this as a courtesy to purchasers of homes and their lending
institutions in order to satisfy certain federal and state requirements, Employees of DHEP do not conduct inspections or
analyze data before acertificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the
professional engineer's work.
Page 2 of 2
72-025 (11/84}
MUNICIPALITY OF ANCHORAGE (MOA)
HEALTH AUTHORITY APPROVAL (HAA)
CHECKLIST - FEBRUARY 1984
MUNICIPALITY OF ANCHORAGE
DEPT. OF HEALTH &
ENVIRONMENTAL PROTECTION
WELL DATA
Casing Height Above Ground
Electrical Wiring in Conduit ~}'N)
Separation Distances from Well:
Well Classification I/VDtMI DgR'/ ' If A, B, C, D.E.C. Approved (Y/N)
Well Log Present (~1) Date Completed ¢l/~(~ Yield
Total Depth ~ ~) / Cased to 6~/0 [
· Depth of Grouting /~//~
Static Water Level -~t¢), "~ / Pump Set At (]~V[~
3, I / Sanitary Seal on Casing ~'N)
Depression Around Wellhead (Y~
To Septic/Holding Tank on Lot I ,~.~/ TO ..,~/P ; On Adjoining Lots
To Nearest Edge of Absorption Field on Lot t2,2'/ /'O $/~2; On Adjoining Lots
To Nearest Public Sewer Line
Cleanout/Manhole
Water Sample Collected by
Water Sample Test Results
N'//~ To Nearest Public Sewer
N/fir To Nearest Sewer Service Line on Lot /~/~'
FAoT0 Y
Comments
B. SEPTIC/HOLDING TANK DATA
Date Installed ~ Size
Standpipes ~)/N) Air-tight Caps ~'N)
,
Depression over Tank (Y,~
Pumping/Maintenance Contract on File (Y/N)
Holding Tank High-Water Alarm (Y/N) N/~
separation Distances from Septic/Holding Tank:
To Water-Supply Well 12.~
To Property Line ~-O
To Water Main/Service Line
Course ! O0 / ~
No. of Compartments 2-
Foundation Cleanout
Date Last Pumped
~V -/~3r 'for
Temporary Holding Tank Permit (Y/N)
To Building Foundation 2.1~ /
To Disposal Field ¥~0 /
To Stream, Pond, Lake, or Major Drainage
Comments ·
Page 1 of 2
72-026(11/84)
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata
Date Installed
Width of Field
Square Feet of Absorption Area
Depression over Field (Y/~
Results of Last Adequacy Test
Type of System Design
Length of Field .~.~ /
Depth of Field ~ /
Gravel Bed Thickness ~ /
Standpipes Present ~}/N)
Date of Last Adequacy Test
71.5 F4¢'/'<Pg Y'
Separation Distance from Absorption Field:
To Water-Supply Well !2.2_
To Building Foundation -.~.~
Lot
To Water Main/Service Line
To Stream/Pond/Lake/or Major Drainage Course
To Driveway, Parking Area, or Vehicle Storage Area
To Property Line I,~' t
To Existing or Abandoned System on
; On Adjoining Lots ~-,~'
To Cutbank (if present)
/O0
Comments
LIFT STATION
Date Installed Dimensions ~'/"*"~'~¢"/
Size in Gallons Manhole/Access (Y/N) .~..--"~
~ Vent (Y/N)
/ Pumping Cycles during Adequacy Test. Meets MOA
"Pump On" Level at _ //~
High Water Alarm Level at
Tested for
Electrical Codes (Y/N) _/
Comments jJ
** Check Permitted Bedroom Rating Against HAA Request
, certify th at, havff~ee~., vLce;i fiT. or con for reed to ~a~ M CA, nd
Signed ~.'~7-~4-¢,¢'~/~ Date
Company / ~C~ I~Ci MOANo
Date of Payment
Amount: $ (~5~
/ WF&& 606
Page 2 of 2
72-026 (tl/84)
.2251 JR,~
ALASKA
el dlI OFIITleFITAL COFITI OL
~nqineerinq 6 ~nuironmenlol
InC.
RICHARD ANSCHUETZ
2841 DEBARR SPACE #32
ANCHORAGE ALASKA
99508
SELLER-SAME
AUGUST 4 1986
RICHARD ANSCHUETZ
2841DEBARR SPACE #32
ANCHORAGE ALASKA
99508
60419
LEGAL:TIMBERLINE BLOCK 0 LOT 15
ADEQUACY TEST FOR SEWER SYSTEM
ADEQUACY TEST DATE-JULY 30 1986
THE TYPE OF ABSORPTION SYSTEM IS A TRENCH WITH AN AREA OF 375 SQFT.
THE SYSTEM IS CAPABLE OF ACCEPTING 450 GALLONS OF WATER PER DAY.
THE SURGE CAPACITY OF THE SYSTEM IS 701 GALLONS.
BASED UPON THE TEST DATA THE SYSTEM IS ACCEPTABLE FOR A
8 BEDROOM HOME.
SEPTIC TANK ADEQUACY
THE EXISTING SEPTIC TANK VOLUME OF 1000 IS ADEQUATE FOR
THIS 3 BEDROOM HOUSE.
THE SEPTIC TANK/PACKAGE PLANT WAS PUMPED ON JULY 31 1986
THIS REPORT DOES NOT VERIFY THE INTEGRITY OP THE PIPING FOR THE WATER
SUPPLY OR WASTEWATER SYSTEM.
FLOW TEST ON WELL
WELL FLOW DATE-JULY SO 1985
A FLOW TEST WAS PERFORMED ON THE WELL, 701 GALLONS OF WATER WAS
PUMPED AT A RATE OF 8.76 GPM OVER A DURATION OF 1.5 HOURS.
THE DRAWDOWN WAS 4.1 ' WITH A RECOVERY TIME OF 10 MINUTES
AND THE STATIC WATER LEVEL WAS 30.3 FEET.
THE WELL IS ADEQUATE FOR THIS 3 BEDROOM HOME.
ALASKA ENVIRONMENTAL
CONTROL SERVlC~ INC.
12OO West 33rd Avenu~ Suite B
ANCHORAGE, ALASKA 99503
Phone 276-1361
Jo. IA5 7'/~_Et~LIN~ Sug
SHEET NO. OF
CHECKED BY DATE
so^LE ! % 20'
,/
INSPECTION APPOINTMEN
TIME TIME ~'~ TIME
DATE DATE DATE
,NSPEOTOR ,NSPEOTO. 'NSPEOTOR )x
~UNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTE~IPALI~ OF ANCHORAG~
825 L Street - Anchorage, Alaska 99501 DEPT.
ENVIRONMENTAL
P~,OTECTION
ENVIRONMENTAL SANITATION DIVISION
Telephone 264-4720 APR 2 3 1981
DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be proce~ed, Please allow ten (10) days for processing,
(if different from
PROPERTY RESIDENT above) PHONE
2, BUY . PHONE
3, LENDING I~I~UT ON PHONE
4. REALTOR/AGENT PHONE
STREET LOCATION
6. TYPE OF RESIDENCE NUMBER OF~BEDROOMS
~,~'~N [] One E~ Four
GLE FAMILY [] Two [] Five
[] MULTIPLE FAMILY I~'"Three [] Six
[] Other
7. WATER SUPPLY
~ INDIVI DUAL* * ATTACH WELL LOG. A well log is required for all wells drilled
[] COMMUNITY since June 1975. For wells drilled pr[or to that date, give well
[] PUBLIC UTI LITY depth (attach log if available.)
8. SEWAGE DISPOSAL SYSTEM
[~/ INDIVIDUAL/ON-SITE** J~ ~ ~ YEAR ON-SITE SYSTEM WAS INSTALLED.
[] PUBLIC UTI LITY
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
THIS SIDE FOR OFFICIAL USE ONLY
1. TYPE OF RESIDENCE NUMBER OF BEDROOMS
[] SINGLE FAMILY [] ONE [] THREE [] FIVE [~ OTHER
[] MULTIPLE FAMILY [] TWO [] FOUR [] SIX
PERMIT NUMBER
2. WATER SUPPLY
[] INDIVIDUAL DEPTH OF WELL
[] COMMUNITY
DATE DRILLED
[] PUBLIC UTILITY
Connection Verified LOG RECEIVED
3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER
[] INDIVIDUAL/ON -SITE DATE INSTALLED
[]PU.UC UT,L,TY
Connection Verified INSTALLER
[]Septic Tank or [] Holding Tank
Size: _l Oi~) If Tank is homemade SOILS RATING
give dimensions: /
TOTAL ABSORPTION AREA MATERIAL
5. COMMENTS
[] APPROVED FOR ~.~ BED[lOOMS
[~CONDITIONAL APPROVAL {letter must accompany certificete)
[] DISAPPROVED
72-O10 (Rev, 6/79)
825 "L" STREET
ANCHOPIAGE, ALAokA 99501
( 9071 264-4111
GEORGE M. SULLIVAN
MAYOR
DEPARTMENT OF ItEALTEI AND ENVIRONMENTAL p~tOFECTION
April 30~ 1981
Carl E. Luchsinger
Post office Box 10-374
Anchorage, Alaska 99511
Sub2ect: Lot 15 Timberline Subdivision
Approval for the individual sewer and water facilities
cannot be granted until the following items have been
completed:
(1) The water analys~s report needs to be delivered
to this office from the Chem Lab, 5633 B Street,
for our review.
(2) Exposed electrical wmres to the well head are in
violatzon of ~he Munmcmpatity of Anchorage codes and
musm be buried. Also, the water line needs uo be
buried and needs to be reinspected by this depargment~
If there are any further questions, please call this office
an 264-4720.
Sincerely,
Rober5 C. Pratt~ R.S.
Associate Spe¢:ialist