HomeMy WebLinkAboutTURNAGAIN #2 BLK 3 LT 4 GREK,,~:R ANCHORAGE AREA BOR~JGH Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM LOCATION LEGAL DESCRIPTION ~ g''~' ~ L~/~'~_'~_.(??-~[/~/Z~Z~..~,~: SEPTIC TANK: DISTANCE INSIDE LENGTH MANU FACTU ~ER ~ MATE RIAL INSIDE WIDTH LIQUID DEPTH COMPARTMENTS LIQUID CAPACITV~)~'~ GALLONS. TILE DRAIN FIELD: DISTANCE FROM WELL/00i FOUNDATION_ / - NUMBER OF LINES / DISTANCE BETWEEN LINES ABSORPT,ON AREA /¢O DEPTH: TOP OF TILE TO FINISH GRADE i_~ TOTAL LENGTH NEAREST LOT LINEd OF LINES /¥/,~ TRENCH W,DT.~ ,N. TOTAL EPPECT,VE SQ. FT. LENGTH OF EACH LINE /~'~ J DEPTH OF FILTER ¢ MATERIAL BENEATH TILE__~/// '~'¢4~ABOVE TILE y IN. WELL: BUILDING NEAREST NEAREST SEPTIC SEEPAGE FOUNDATION __, LOT LINE ~ SEWER LINE~, TANK SYSTEM DISTANCE FROM: CESSPOOL OTHER SOURCES APPROVED __ DISAPPROVED REMARKS DISTANCES: SEWER LINE DEPTH: REMARKS: DIAGRAM OF SYSTEM GREATEr ANCHORAGE AREA BOROUGH /, NAME OF APPLICANT INSTALLATION LOCATION LEGAL DESCRIPTION ~/~::% ~K~ MAILING ADDRESS ~7~ / E~//~-~/~K~ PHONE INSTALLATION OF: SePTiC TANK SEEPAGE PIT , DRAIN fIELD TYPE AND SIZE Of FACtLITY tO BE SERVED ~l ~ ~/ ~ O/~C~ ~ FINANCED THROUGH TO BE INSTALLED BY ~ ~' COMPLETION DATE ANT]CIPATED ~L /~ ~ NOTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTrC TANK size /~OO ,~/~L TYPE SEEPAGE AREA SIZE MINIMUM DISTANCES, REOUIREMENT5 FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE P~rP~ SEPTIC TANK TO SEEPAGE ~ WELL TO SEPTIC TANK DRAIN FIELD WATER MA[N TO SEPTIC TANK '" DRAIN FIELD , SEEPAGE TO RIVER, LAKE, STREAM. DRAIN FIELD ALSO CONSIDER AREA WELLS. SEEPAGE Pit DRAIN FIELD CAST IRON INTO AND OUT OF SEPT]C TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. CONFOR~I TO BOROUGH REGULATIONS REGARDING INSTALLATION. TYPE DIAGRAM OF SYSTEM I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO, 28-68 AND THAT THE ABOVE DATE ~) APPLICANT'S SIGNATURE~. October 9, 1975 R & M NO. 562139 C. B. Duke 3701 Eureka Space 4lA Anchorage, Alaska Test Hole and Soil Log Report for Sanitary System Lot 4, Block 3, Turnagain Subdivision ~1 Dear Mr. Duke: We are submitting herewith the test boring results and our comments regarding soil conditions encountered at the subject site. This inves- tigation was performed in accordance with your request of October 8, 1975, and those procedures outlined in a letter dated July 15, 1975, by. Mr. Rolf Strickland of the Greater Anchorage Area Borough Department of Environmental Quality. A single test hole was pu~ down within the Lot 4 area for the purpose of defining general subsurface soil conditions for the proposed sanitary system. Excavation was accomplished with a tractor-mounted backhoe and the test hole was extended to a total depth of 13.0 feet below ground surface. The final log prepared for the test hole has been included in Drawing A-01. Ground water was not encountered in the test hole. We appreciate being given this opportunity to be of service to you. Should you have any questions with regard to the above, please do not hesitate to contact us. Very truly yours, R & M CONSULTANTS, INC. Jmes .. Rooney ) Vice President ~ ' JWR/~,mD/ja Encl. xc: GAAB N KLATT ROAD Lot 4 /~ TH-1 ~ TH-1 10-8~75 ORGANICS w/SO~ SILT SO~ SAND TRACE GRAVEL LARGE I~OD FRAGMENTS (Fill?) SILT NO WATER TABLE 0.0t 4.01 13.0' T.D. no scale Log represents location of test hole Lot 4, Block 3, Turnagain Addition~l~2-~ Subdivision R Consultants nc. ~ ANC.O~^~ ~Am~.~S ALASKA JUN[AU ~D CHESTER DUKE PROPERTY Log of Test Hole Anchorage, Alaska IP~:~. NO. 562139, ,, IDv',~ NO. A-O1. OAT~ 10--9--75 IS¢~Lm 1"=3' laWN m~ WED , ICH~O ~¥ MUNICIPALITY OF ANCHORAGE Health and Environmental Protection Sewer and Water Section 264-4720 Soil Test Soil testing of each residential lot establishes sewer system design criteria. Testing is usually conducted by two(2) methods: (a) (b) Percolation Test - water absorption rate is determined by using an augered hole sixteen(16) to twenty(20) feet in depth and conducting visual and water absorption test in appropriate strata. This test is accurate for all types of soils. ~' Visual analysis is an excavatibn site of sixteen(16) to twenty(20) feet in depth. This is accurate for gravelly type soils ONLY. A percolation test is required if the visual analysis shows soils rated greater than 150 square feet per bedroom. (c) In all cases, the test must be run to a depth of four(4) feet below the bottom of the proposed disposal system. This is to ensure the system is at least four(4) feet above any water table. Soil tests determine the ability of soils to absorb sewage. The on-site sewer system design will incorporate total sewage productio~ and required absorption area for each residence. GRAVELS RATING GW - well graded gravel and sand GM - silty, sandy gravel GP - poorly graded gravels or gravel-sand 85 sq.~ feet per bedroom 225 sq. feet per bedroom 125 sq. feet per bedroom II. SANDS A. SW - well graded sands and gravel 125 sq. B. SP - poorly graded sand 150 sq. C. SM - silty sands 250 sq. feet per bedroom feet per bedroom feet per bedroom Iii. SILTS A. ML - silt, fine sand mix 275 sq. feet per bedroom IV. CLAYS A. CH - clay, silt and mix 350 sq. feet per bedroom *Percolation test required on soils greater than 150 square feet per bedroom. Rev. 10/79