Loading...
HomeMy WebLinkAboutTURNAGAIN BLK 3 LT 2Sic, ~--AMUNICIPALITY OF ANCHORAGE ,~_~ Hea'~, la and Environmental Prote( !on Fourth Floor West 825 L Street Anchorage, Alaska 99501 279-2511, x 224, 225 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM SEPTIC TANK: EROM WELL k/~ INSIDE LENGTH .~ .'~. ./~ ~] _ ,~ iN]UMBER OF INSIDE WIDTII LIQUID DEPTH LIQUID CAPACITY/<~. ALLONS. ~l~),~'O ~ / TOTAL LENGTH DISTANCE BETWEEN LINES _~ ~/~ TRENCH WIDTH~ IN, TOTAL EFFECTIVE ABSORPTION AREA___~_ SQ. FT. LENGTH OF EACH LINE ~ / / DEPTII OF FILTER ;~ DEPTII: TOP OF TILE TO PINISIt GRADE .._~ ' ._.MATERIAL BENEATH TILE .~ _IN. ABOVE TILE _~_ ~ SEEPAGE PI'r: DIAMETER -- OR WIDTH ..... LENGTH___, DEPTH Log.__ Crib Rings/CRIB SIZE: BUILDING FOUNDATION NEAREST LOT DIAMETER ..... DEPTlt____ DISTANCE EROM: WELL .. TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) ,SQ. FT. Class.~. Depth: Well Distance To: Lot Line Bldg: Sewer Line: Pipe Materials: # of Bedrooms: Installer: d~ ~ ~- Remarks: F'ERMIT NO. ( .... "~ FFL] _.Hr4T LOCFIT 1 ON - LEGFtL _,Fill ~ M_,LUNI E,R_HD[' '" - 'l..I.=,~MHl~.'r'- " "' R',¢'E L 2 B-... ~ TURNRGFIIN SD SRFl E,O,., LOT SITZE 2:44700~: 2L4000 SQIJRRE FEET T'¢PE OF =,CIL FlE:SORBTION bT_,TEM IS: FREN_.H MFIXIMUM NI_IMBER OF BEDROOMS SOIL RATING c'SQ FTzE, R .... :3~ THE REC!IJIRED bI~E OF THE SOIL FIBSORPTII]N _,9¢TEfl IS: [)EF'I-H= :.1_± L E I'-.!12~ T H = :'L '--'--~ THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DF.'.FIINFIELD. THE DEPTH CIF R TRENCH OR. PIT IS THE DISTFlNCE BETWEEN '/HE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCFIVRTION KIN FEEl"). THERE IS NO SET WIDTH FOR I'RENCHES. THE GRFlVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFFILL PIPE FIND THE BOTTOM OF THE E×CRVFITION (IN FEET). E:Ei~;~J .T. RED . :--_;EF"'T I C: TRNI<: S I ZE= PRI]i--'.R,3E F'LR['-.I]- OP'T I Cut'-,I ta PFIC:KRGE PLFINT MFl¥ BE INSTFlLLED FIT THE PERHITTEE'S OPTION SUBJECT TO THE FOLLOWING CONDITIONS: :t. EITHER tR CLFlSS I OR ti NSF FIPPRO'v'ED PLFINT MFlY BE INSTFlLLED. ;2'..FI CONTINUOUS HRINTENRNCE RGREEMENT IS REQUIRED. IF FI MFIINTENFINOE AGREEMENT IS NOT KEPT CURRENT k'OU MFl¥ BE REF4UIRED TO ENLARGE THE SOIL ABSORPTION SYSTEM FIND/OR YOU MFI'¢ BE SUBJECT TO PROSECUTION. BHL.[,FILLIN.~ OF FlN¥ _,T_TEM WITHOUT FINAL INSPEC:TION FIND FIF'F'ROVRL E,T '['HIS DEPFlRTNENT [,]IL..[. 6E ~U6JEL. T TO PROSECUTION. NINIMLIM DISTFINCE BETWEEN R WELL. RND AN9 ON-SITE SEWFlGE DISF'OSRL SgSTEM IS i00 FEET FOR R PRIVFITE WELL OR 200 FEET FOR R PUBLIC WELL.. WELL. LOGS ARE REQUIRED AND MUST BE RETURNED TO THE DEPFlRTMENT WITHIN 30 DAMS OF THE WELL. COMPLETION. OTHER REQUIREMENTS MFlY FlPPLY. SPECIFICFlTIONS FIND CONSTRUCTION DIFIGRRMS ARE FIVRILRBLE TO INSURE PROPER INSTFILLRTION. . - .-~ L]~ ~1_ .. dL _- F'EF:~-I ][ T E:=-~.F" .l: F._E_ [)E,:]E~-IBER ' I CERTIF'¢ THAT i: I FlM FFIMILIFIR WITH THE REC!UIREMENTS FOR ON-SITE SEWERS laND WELLS FlS SET FORTH B'¢ ]'HE MUNICIPFIL. IT¥ OF FtNCHORFIGE. 2: I WILL INSTALL THE SYSTEM IN FICCORDRNCE WITH THE CODES. $: I UNDERSTAND THFlT THE ON-SITE SEWER ~YSTEM MR'~ REQUIRE ENLARGEMENT IF THE RESIDENI]:E IS ~:EMOE:,ELED TO INmZ:LI_IDE MI]IRE THAN 3: E:EDROOMS. .- ~¢'PL. IC:RNT SAM '¢R.SC:ONI MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION Pouch 6-650, Anchorage, Alaska 99002 276-2224 SOILS LOG - PERCOLATION TEST ySOILS LOG [] PERCOLATION TEST PEREOR~O ~oR: ~h~Y~ 2 10- 11- SLOPE WASGROUND WATER ENCOUNTERED? 12 13 14 15 16 17 18 19 20 DATE PE.FO.MEO: "'7-- 5o - '7 -7 SITE PLAN IF YES, AT WHAT DEPTH? Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE (minutes/inch) TEST RUN ~ETWEEN '~"~ FT AND ~" , FT .-* 72-008 (7/'76)