HomeMy WebLinkAboutTURNAGAIN BLK 3 LT 4O/(x-I q ,lS,'o° MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME John Lowe ~AILINGADDRESS 8620 Jade Street, Anchora?; Alaska Qq~fl? LEGAL DESCRIPTION iht 4: Rln£k 3 , Turnagain Subdivision LOCATION Broadus Street Sunset Plastl cs 2500 I IF HOMEMADE: DISTANCE TO: Well Manufacturer . IWell NDt In 5 ft. PHONE [~NEW 243-5547 []]UPGRADE Absorption area 17 ft. Insidelength Dwelling DweUing 1 5 ft. Width Material Foundation Nearest lot line 50 ft. Trench w dl0 ft. Total length of lines 50 ft. inches Material beneath tile +~" screened qravel 7 ft. inches Depth NO. OF BEDROOMS ~]ex-8 bdrms, PERMIT NO. 780902 Liquid depth PERMIT NO. Liquid capacity in gallons PERMIT NO. 780902 Distance between lines Total effective absorption area 700 sq. ft. PERMIT NO. Crib depth Total effective absorption area Building foundation Nearest lot line Driller Distance to lot line PERMIT NO. Sewer line Septic tank Absorption area(s) OTHER PIPE MATERIALS Pln~t~c AgTM D-3Q34 Sb ~ L~'~EST RATING 85 INSTALLER C & O Excavating REMARKS .=~8 3:00 p.m. 1st Inspection o ~ 2nd Inspection 9-29 9:30 a,m. 3rd Inspection 9-29 3:30 p.m. ~%~ ~o. 1783-[ ..~ ~AIAL ~)~,~°G-GREY & ASSOCIATES, INC. D~-T2~9-78 LEGAL By: Alvin R. Zeman, P,E. 72-013 (Rev. 3/78) PERMIT NO. r-luN I C I ~ AL I TY OF ANCH,~RA*~E DEPARTMENT OF HEALTH 8ND ENVIRONMENTAL PROTECTION 825 'L' STREET, ANCHORAGE, AK. 9950i 264-4?20 WELL A~4D O~4--~SITE SEWER PEAr4 IT ( 780902 > APPLICANT LOCATION LEGAL JOHN LOWE BROADDUS L 4 BLK ~ 8620 JADE ST LOT SIZE 24~ 5547 14400 SQUARE FEET TYPE OF SOIL 8BSORATION SYSTEM IS: TRENCH MAXIMUM NUMBER OF BEDROOMS = 8 SOIL RRTING (SQ FT?BR>= 85 THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: DEPTH= ii LENGTH= 49 GRAVEL DEPTH= 7 THE LENGTH DIMENSION IS THE LENGTH (IN FEET> OF THE TRENCH OR DRAINFIELD. THE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION <IN FEET>~ THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRRV~ BETWEEN THE OUTFALL PIPE AND THE BOTTOM OF THE EXCAVATION (IN FEET>. RE~'-.!~J I RED SEPT I C TANK S I ~'E= 2250 PERMIT APPLICANT MAS THE RESPONSIBILITY TO INFORM THI~ DEPARTMENT DURING THE INSTALLATION INSPECTIONS OF ANY WELLS MDJACENT TO THIS PROPERTY 8ND THE NUMBER OF RESIDENCES THAT THE WELL WILL SERVE. T~O (~ 2 ) I N~PECT I OFIS ARE REQU I RED BACKFILLING OF 8N¥ SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTfNCE BETWEEN 8 WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS 100 FEET FOR 8 PRIVATE WELL) OR 150 TO ~00 FEET FROM 8 PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL. WELL LOGS ARE REQUIRED AND MUST BE RETURNED TO THE DEPARTMENT WITHIN ~0 DAYS OF THE WELL CGMPLETION. OTHER REQUIREMENTS MAY APPLY, !SPECIFICATIONS AND CONSTRUCTION DIAGRAMS 8RE AVAILABLE TO INSURE PROPER INSTALLATION. PERM I T EXP I R~S DECEMBER --~l.. i~78 I C£RTIF~ THAT i: I AM F~MILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWE~ AND WELLS AS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE, ' 2: I WILL INST~LL THE S~STEM IN 8CCORD~NCE wITH THE OODES~ ~: I UNDERSTAND THAT THE ON-SITE SEWER S~STEM M8~ REQUIRE ENLARGEMENT RESIDENCE IS REMODELED TO INCLUDE MORE THAN 8 BEDROOMS. ..... 8P~ JOHN LO~ IF THE V-~. 2 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION Pouch 6-E50, Anchorage, Alaska 99502 276-2221 SOILS LOG - PERCOLATION TEST [] SOILS LOG [] PERCOLATION TEST PERFORMED FOR: DATE PERFORMED: LEGAL DESCRIPTION: 7- 8- 9- 10- 11 12 13 14 15 16 17 18 19- 20- SLOPE WAS GROUND WATER ENCOUNTERED? SITE PLAN IF YES, AT WHAT DEPTH? Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE (minutes/inch) COMMENTS TEST RUN BETINEEN FT AND FT PERFORMED BY: 72-008 (7/76) CERTIFIED BY: /"[O~'---N~,q~,-- ~.~.V ~ DEPT. OF ENVIRONMENTAL CONSERVATION SOUTHCE~TRAL REGIONAL OFFICE / ~3~ DE~ALI STRE~ / Ma~Y BUILDINg, ROOM 1~ A~CHO~E September 21, 1978 Buster Newton Newton Investment Company 411 E. 36th Avenue .Anchorage, AK 99503 Subject: L4, B3 Turnagain Subd. Dear Mr. Newton: We have received and reviewed the plot plan of the subject lot showing the proposed well and septic system locations. As discussed, the horizontal separation between the well and septic system will be 164 feet. Thus, the project is hereby approved for the features with which this department is concerned. The results of a bacteriological analysis of the well water should be submitted to this office as soon as possible upon completion of well construction. Sincerely, ~Ja~/~s O.~ Star~ Environmental Engineer cc: DHEP gml POUCh 6-650 ANCHORAGE, ALASKA 99502 (907) 264-4111 GEORGE M. SULLIVAN, MA YOR DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION (825 "L' Street) October 12, 1978 John Lowe 8630 Jade Street Anchorage, Alaska 99502 Subject: Four-plex on Lot 4 Block 3 Turnagain Subdivision This department can not approve the sewer installation on the subject property. The leaching trench is placed in the right-of-way easement. In order for you to get final approval,.you will need to move the leaching trench within the lot lines on the subject lot or get an easement waiver from the owner of the easement. If there are any further questions, please contact this office at 264-4720. Sincerely,~ Robert C./~r/a~[, R.S. Associate Specialist RCP/ljw October 12~ 1978 J~% Starr State of Alaska Department of E4%vironmental Conservation ¥~c Kay Building 338 Denali Street Anchorage, Alaska 9950]. Subject~ F0ur-plex Located On Lot 4 Block 3 Turnagain Subdivision Enclosed is a copy of a letter sent to Buster Newton. ~lis department has received numerous complaints re~arding the protective radius between the subject well and ? neighboring private sewer systems. After investigating the complaints, I'found the following: (1) The four-plex well is one-hundred thirty five(135) feet from the seepage pit standpipe located on Lot 5 Block 3 Turnagain Subdivision, and one-h~%dred nineteen(il9) feet from the septic tank standpipe located on Lot 2 Block 3 Turnagain Subdivision. (2) The four-plex's well is one-hundred forty-flve(145) feet from the septic tank serving the subject property. If there are any questions, please contact me at 264-4720. Sincerely, Robert C. Pratt~ ~ Associate Specialist RCP/ljw co: File MUNICIPALITY OF ANCHORAGE  DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTI~t~/IRONMENI'AL ~,,; ~.CTION ~ 825 L Street - Anchorage, Alaska 99501 ENVIRONMENTAL ENGINEERING DIVISION APR 9 ~979 Te,ep.o.e 2B4-472o R E CcE, j_ygsD REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FA I MUNICIPALITY OF A~FIOP~G~ DEPT. O; ~4SALTH & / , ~ ~' DIRECTIONS: Complete all parts on page 1: Incomplete requests will not be processed, Please allow ten (10) days for processing~ PHONE 1. PROPERTY OWNER MAILING ADDRESS PROPERTY RESIDENT (If different from above) PHONE PHONE 2, BUYER PHONE MAI LING A DDR ESS PHONE 3. LENDING INSTITUTION MAILING ADDRESS~ 4. R E~T~O R/AG ENT STREET LOCATION B. TYPE OF RESIDENCE NUMBER OF BEDROOMS (-~/ [] One [] Four ~ Other [] SINGLE FAMILY [] Two [] Five ~' MULTIPLE FAMILY [] Three [] Six 7. WATER SUPPLY INDIVIDUAL* [] COMMUNITY [] PUBLIC UTI LITY 8. SEWAGE DISPOSAL SYSTEM P~ INDIVI DUAL/ON-SITE** [] PUBLIC UTILITY * ATTACH WELL LOG. A well log is required for all wells drilled since June 1975. For wells drilled prior t~that date, give well depth (attach iog if availabJe.) ~ ,,~. **1 f individual/on-site, give installation date If system is over two (2) years old an adequacy test is required by this Department. NOTE: THE INSPECTION FEE MUST AccoMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. THIS SIDE FOR OFFICIAL USE ONLY DATE RECEIVED INSPECTION APPOINTMENTS TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR INSPECTOR 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS [] SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2. WATER SUPPLY [] INDIVIDUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTI LITY Connection Verified LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER L~INDIVIDUAL/ON -SITE DATE INSTALLED E3PUBLIC UTILITY Connection Verified iNSTALLER []Septic Tank or [] Ho]ding Tank Size: If Tank is homemade SOILS RATING give dimensions: TYPE OF TTANK MANUFACTURER TOTA L~-BSOR PTION AREA MATERIAL 4. DISTANCESwELL TO: Beptic/HoJding Tank Absorption Area Sewer Line Nearest Lot Line ~bsorption Area to nearest Lot Line 5. COMMENTS ~PPROVED FOR ~ BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany certificate) [] DISAPPROVED ~ATE BY (Titl LEGAl_ DESCRIPTION 72-010 (Rev, 3/78) ROOM 1208 RECEIVED Howard Grey Moening - Grey & Associates 715 L Street, Suite 8 Anchorage, Alaska 99501 Subject: L4, B3 Turnagain Subdivision Dear Mr. Grey: We Have received and reviewed your request for a waiver of the separation distance requirements pertaining to the class C well drilled on the subject lot. The waiver is hereby approved pro- viding the well casing is grouted down to the clayey sand layer (33 feet). This office should be notified when the grouting operation is arranged as we will need to inspect the process. I have not beenlable to locate a copy ef the drilleris log in · · Please our file so I~apprecmate it mf you would send us a copy. feel free to contact me if you have any questions regarding the conditions of this waiver. Sincerely, James O. Start Environmental Engineer cc: DHEP - Bob Pratt llm 18-O6LH DEPT. OF ENVIRONMENTAL CONSERVATION 338 DENALI SREET MACKA Y BUILDING, ROOM 1206 ANCHORAGE, ALASKA 99501 April 13, 1979 Howard J. Grey Morning-Grey & Associates 715 L Street, Suite 8 Anchorage, Alaska 99501 'MUNIcIpALITy OF ANCFIORAGE EI'~VIRoh '~ : F NT,~j. . CT/ ON RECEIVED Subject: L4, B3 Turnagain Subdivision Dear Mr. Grey: At your request we have reexamined our conditional approval of the separation distance waiver for the class C Well lo- cated on the subject lot. It is our feeling that the poten- tial for contamination is sufficient in this case to justify grouting of the upper soil strata. If this was a flowing artesian well, we agree that contamination from the surface would be highly improbable. This, however, is not the case as the static water level is about 50 feet below the ground surface. In addition, I feel we were misled when the case was first presented for construe-ion a~since the in- formation regarding the neighboring septic systems was not furnished. This res~ulted in the well being drilled before we l~~_~he >s~p_a~ation ~c~u~b~- IS'~AC/80.020 ~ not be satisfied. ~o~r-~h~asons~We~ar~nq ¥~r ~equest t~at grouting of the upper 33 feet ofithe well not be requi~ed.~-~n--~the-r~words, the conditional a~proval contained in my April 6, 1979 letter remains in effect.. If you still feel justified in seeking an unconditional waiver, you do have a right to an adjudicatory hearing to con- test the department's denial. A request for an adjudicatory hearing must be made within 30 days of receipt of this letter by mailing or delivering a statement of issues to the Alaska Department of Environmental Conservation, Pouch O, Juneau, Alaska, 99811. The statement of issues must state the basis 18-O6LH Howard J Grey Page 2 James O. Starr for the hearing request and otherwise conform With AS 4~62.370. A failure to request a hearing within 30 days of receipt of this letter constitutes a waiver of your right to administra- tive or judicial review of this action. Please feel free to contact me at 274-5527 if you have any questions regarding the contents of this letter. Sincerely, James O. Starr Environmental Engineer ,~/cc: DHEP - Bob Pratt ANCHORAGE, ALASKA 99502 (907) 279 2511 GEORGE M. SULLIVAN, MAYOR DEPARTMENTOF HEALTNAND ENVIRONMENTAL PROTECTION (825 "L" Street} April 11, 1979 Henry T. Newton/John Lowe 411 East 36th Avenue Anchorage, Alaska 99503 Subject: Lot 4 Block 3 Turnagain Subdivision Approval for your individual sewer and water facilities will not be granted until the following items have been. completed: (1) The top of the well casing is sealed with a sanitary seal so that it is air tight. (2) The water analysis report be delivered to this office from Chem Lab, 5633 B Street, for our review. (3) See the attached letter. Notify this department for a re-inspection whe~ descrepancies have been corrected. If there are any further questions, please contact this office at 264-4720. Sincerely, Robert C. Pratt, R.S. Associate Specialist RCP/ljw CC: Security National Bank Mortgage Loan Department 880 H Street 99501 MOENING-GREY ~ ASSOCIATES, INC. GEOLOGISTS AND ENGINEERS April 19, 1979 James O. Starr Environmental Engineer State of Alaska Department of Environemtnal Conservation Southcentral Regional Office 338 Denali Street McKay Building, Room 1206 Anchorage, Alaska 99501 Re: Lot 4, Block 3, Turnagain Subdivision Dear Jim: In accordance with your letter of April 13th, the periphery of the well casing for the Lot 4 water supply well was grouted'. This was accomplished by jetting grout pipes to the pre- determined 33 foot elevation,.and withdrawing these as the grout was pumped under pressure. 2~wo grout pipes were inserted for this purpose in order to provide an uninterrupted curtain around the well casing. The grout pump has a maximum pressure capacity of 150 PSI. As recommended, the grout procedure was discontinued at 15 feet in order not to encase-the pitless adaptor. If you concur in the above stated procedure and agree that the work as completed will meet the requirements set forth in your letter of April 13th, please sign in the space provided. We Page 2 James O. Start Lot 3, Block 4, April 19, 1979 Turnagain Subdivision have attached an additional copy of this Thank you for your cooperation. Sincerely, MOEN~G-GI~E~S, INC. Howard J. Gr~J~,/ HJG/tg letter for your files. I CONCUR IN THE ABOVE STATED GROUTING OPERATION. James O. Starr Environmental Engineer Date