Loading...
HomeMy WebLinkAboutTURNAGAIN BLK 3 LT 6 > DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME ~ PHONE I Abs°rpti:~-'a ~alnside length IF HOMEMADE: Well Dwelling PERMIT NO. Liquid depth Manufacturer I Material Liquid capacity in gallons T°t al le~'f~flines I Tren~l '~h inches Material ~eneath tile Depth DISTANCE TO: [Well z /~--O / Length f h ne Width Length DISTANCE TO: OTHER PIPE MATE RIALS Di st a n c e I/~.,~'.~n e s' Total effective absorption area PERMIT NO.~' (~ (~1 Type of crib Crib diameter Crib depth Total effective absorption area DISTANCE TO: Well Building foundation Nearest lot line 3Jass Depth Driller Buildln9 foundation Sewer line Distance to lot line Septic tank REMARKS DEPARTMENT OF HEALTH AND ENVIRONMENTAL P OTECTION 0~4--S I TE PERMIT NO. ( 800013 > ROBERT SLEININGER SEWARD HWY LT. ~ BU.',3 TURNRGAIN S?D'~ LOT SIZE APPLICANT LOCATION LEGAL iG000 SQUARE FEET <SQ FT,,.'BR)= ~~ TYPE OF SOIL ABSORPTION SYSTEM IS: TRENCH MAXIMUM NUMBER OF BEDROOMS = 4 SOIL RATING THE REQUIRED SIZE OF THE SOIL ABSORPTION ~¥STEM IS: DEPTH= ii LEF4GTH= 43 I]RA%~EL DEPTH= THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRAINFIELD. THE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE AND THE BOTTOM OF THE EXCAVATION (IN FEET). REQUIRED SEPTIC TANK SIZE= -1250 GALLONS PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE NUMBER OF RESIDENCES THAT THE WELL WILL SERVE. THO (2) I t~SPECTIOt~S ARE RE(;~L~IRED BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS 100 FEET FOR A PRIVATE WELL OR 150 TO 200 FEET FROM A PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. PERM I T E~<P I RES DECEMBER I CERTIFY THAT ±: I AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS RS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE 2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. -?.: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THAN 4 BEDROOMS. S I GNED: ......... , , ~. AFPLICRNT ROBERT SLEINI~ER ~) '~ / '9'4. 0 February 13, 1980 R&MNo. 051001 Robert Sleininger Star Rt. A, 1388C Anchorage, Alaska Subject: Soil Investigation for Sanitary Sewer System, Lot 6, Block 3, Turnagain Subdivision, Anchorage, Alaska Dear Mr. Sleininger: At your request of February 4, 1980, we conducted a snbsurface soils investi- gation at the proposed location of the sanitary sewer system on the subject lot. The investigation complied with those procedures required by the Municipality of Anchorage Department of Health and Environmental Protection. This ~nvestigation, which was accomplished on February 13, 1980, consisted of a test hole drilled to a depth of 20 feet below the existing ground surface. The test hole was sited according to your instructions and its location is shown in attached Drawing A-01. Drilling was accomplished with a rotary drill rig using continuous flight solid-stem auger with an outside diameter of 6 inches. A sample was taken at the depths shown on the soils log in Drawing A-01. The sampl~ will be held in storage at our lab for approxi- mately six months. In addition, all material brought to the surface by the augers was continuously monitored by an experienced engineering geologist. The topography at the drilling site is generally horizontal. At the time of the investigation the site had original vegetation consisting of birch and spruce. The top of the test hole was located at original ground surface. February 13, 1980 Robert $1eininger Page -2- The soils encountered in the bore hole are shown in the test hole log in Drawing A-O1. This log displays specific conditions encountered at the test location. However, subsurface conditions may vary in other parts of the lot without any apparent surficial evidence of the change. Groundwater was not' encountered. Bedrock was not encountered. At the time the hole was drilled seasonal frost was present from the surface to a depth of 1.5 feet and permafrost was not encountered. Based on the visual classification of the soil and the requirements set forth by the Muncipality of Anchorage, a percolation test was not necessary within the test hole on the subject lot. We appreciated this opportunity to be of service to you. Please contact us if you have any questions concerning this letter or if we can be of addi- tional service. Very truly yours, R&M CONSULTANTS, INC. Jeff Ayres Staff Geologist JA: GS/dj/ATSI-A NUMBER Date Completed: SOIL DESCRIPTION SILTY SAND (SM-ML) Brown, Moist, Med. Dense 2.0 SILTY SAND w/SOME GRAVEL (SM-ML) Brown, Slightly Moist __~3.0 SAND (SP) Brown, Fine Dry Medium Dense 6.5I GRAVELLY SAND (SP) Brown, Dry, Med. Dense 9.5~ SANDY GRAVEL (GW) Occasional C6bbles Brown,Dry, Dense 15' SAND (SP) Brown, Dry, Dense T.D. 20' Groundwater Not Encountered LOCATION SKETCH Lot 6, Block 3 Turnagain Subdivision No Scale !,Existing House 3 "~1 ~ TH 1 NOTE; DISTANCES SHOWN ARE APPROXIMATE AND HAVE NOT BEEN MEABUREO BY SURVEYING METHODS. EXPLANATION ~ ..~ ORGANIC MATERIAL ~:¢ Little Visible Ice O:10' Vx ~ SAMPLE NUMBER _~ ~i9-'c- ~'Ss,72,5ZlO/o,85.9pcf q I/LWATER cogENT 5 ~: ~ BEDROCK t~FROZEN GNOUNO ~/2-WHILEDNILUNB TYPICAL SOILS LOG ~. A.~-AFTERRORINS Sh ~5" BP~IT SPOON W/TH S40 £~ HAMMER SAMPLER TYPE SYMBOLS J. SOIL SYMBOLS R &~M ?ONSULTANTS~ INC./1 LOG OF TEST HOLE ROBERT SLE IN]NGER ANCHORAGE, ALASKA GRID, .DE10 I LDWG~O. ~-0i,' ) PE'Rkt I't" N ]., ~..,rt-L.~ ..mn,~ ROE;i!.:-'R]' ,,~,, SL.EZIi'q)J'qGli':'iR STAR RI]U'FE A E)OX L..JuA z..~'~ iiC,! BROA[.)C, UW I F'ilAI LOT 6 I~LOcK B 'I'URNAgAiN r---..) . ........... ~fLi LOT SiZE 99507 ~ :[~Jp()O S(iUAHE FEE'i' M:i.n:imum d:i.s't~s',,'~!::e between a well and any om--s~te sewage di. sposal system ~.s !0(} -Feet ~(:)*" a pp:i. vate well on :1.50 to ;6:00 ~:eet 'Fr'om a publ/.c ,~e:l.:t. depending upon the ~:ype o.F public ,~el)... I~l:i.n~.i~u'm d~.?~ance ~Pom a pp~.vate well to a pP~va'te sewer' l:i. ne ~s ~S .Feet and to a c:emm{m:i.t'y se~,¢ep l:[ne :is '7S {:eet. Well legs ,~?e Pequ:ined and must be ne'tur, ned to the deDaptment wJ. tt"~n 30 days o'F the well compiet:[on~ Othem re.'4u:i.r'emen'ts may apply, Spec~.'F:[catJ. ons and constr'uct{or, diagr'mms ace aua:i, leble to :i. nsupe pr. oper. :i. nstali~t:i, on,. i cer"t{~y tk, a~t I~ i am Fam~.:!.iac w:i. th the requir'ements for' on-site sewens and wells as set 'Fop~:h !:)y 'the idi..mJ.¢::[p;]l~::y o'F ./'4nchopa..'.3.'e. ~2;', i w~.ii :i.!'~--]tail the system :in accopdance wi. th the codes. i"IUN I ¢ I ~I=IL I TY OF R~4CHORRGE · DEPFIRTMENT HEALTH FIND ENVIRONMENTRL/~<~OTECTION~ ~ 264-472~ LOT SIZE " SOIL RATING (SC PT/MR)= MRXIMUM NUMBER OF BEDROOMS = SQLIFIRE FEET THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: DEPTH= - LENGTH= GRAYEI DEPTH= THE L~NGTH DIMENSION IS THE LENGTH <iN FEET) Of THE TRENCH OR DRAINFIELD. THE DEPTH OF 8 TRENCH OR PIT IS THE DISTFINCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFRLL PIPE RND THE BOTTOM OF THE EXCAVATION (IN FEET). RED TRNK :S; I ZE~ PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE NUMBER OF RESIDENCES THAT THE NELL WILL SERVE. TWO ( 2 ) I N;~,PECT I 01'4~ RRE REQU I RED BACKFILLING Of RNY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTRNCE BETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS 100 FEET FOR A PRIVATE WELL~ OR 150 TO 200 FEET FROM ~ PUBLIC NELL DEPENDING UPON THE TYPE OF PUBLIC NELL. WELL LOGS ARE REQUIRED AND MUST BE RETURNED TO THE DEPARTMENT WITHIN ~0 DRYS OF THE WELL COMPLETION. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS RND ~ONSTRUCTION DIAGRAMS FIRE ~VFIILABLE TO INSURE PROPER INSTALLATION. PERMIT EXPIRES DECEMBER I CERTIFY THAT l: I RM FRMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS FIND WELLS RS SET FORTH BV THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTALL THE SYSTEM IN ~CCORDRNCE WITH THE CODES. 3: I UNDERSTAND THRT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLRRGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THAN ~ BEDROOMS. RPPL I CANT V~. 2 825 "L" STREET ANCHORAGE, ALASKA 99501 (907) 264-4111 GEORGE M. SULLIVAN, MA ~'OR DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION December 31, 1980 Robert G. Sleininger Star Route A Box 1388C Anchorage, Alaska 99507 Permit ~ 800049 Subject: Lot 6 Block 3 Turnagain Subdivision A permit issued by this department for well and/or sewer system has expired as of this date. Permits are issued on a calendar year basis, as stated on the permit, by authority of Municipal Ordinance. If you have drilled the well, a well log should be sent to this department to document the installation date. If an engineer inspected the installation of the on-site sewer system, please have them send us the as-builts for our files. If there are any further questions, please call this office at 264-4720. Sincerely, sLeenSioN; ~nUvC~hro°n~ntR~'~cialist LNB/ljw enc: Copy of Permit SWP/057 t DATE RECEIVED ,' . INSPECTION APPOINTMENTS TI~E TIME TIME DATE DATE DATE INSPECTOR INSPECTOR ~V~UN C PALITY OF ANCHOEAGE MUNICIPALITY OF ANCHORAGE DEPT. O~ ,.' ~',~'~'"'  DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTIO  825 L Street - Anchorage, Alaska 99501 ) ENVIRONMENTAL SANITATION DIVISION MAR 2 0 Telephone 264-4720 MAILING ADDRESS PROPERTY RESIDENT (If different from above) / PHONE 2, BUYER PHONE MAi LING ADDR ESS 4. REAL~OR/AGENT PHONE 5. LEGAL DESCRIPTION STREET LOCATION 6. TYPEOFRESIDENCE SINGLE FAMILY ~ MULTIPLE FAMILY NUMBER OFtBEDROOMS [] One [] Four [] Two [] Five ~ Three [] Six [] Other 7. WATER SUPPLY ~]' INDIVIDUAL* * ATTACH WELL LOG. A well log is required for all wells drilled [] COMMUNITY since June 1975. For wells drilled prior to that date, give well [] PUBLIC UTI LITY depth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM ~ INDIVIDUAL/ON-SITE** I(~.[~, YEAR ON-SITE SYSTEM WAS INSTALLED. [] PUBLIC UTILITY NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-olo (Rev. 6/79) THIS SIDE FOR OFFICIAL USE ONLY 1, TYPE OF RESIDENCE NUMBER OF BEDROOMS E3 SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER E] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2. WATER SUPPLY [] INDIVIDUAL DEPTH OF WELL E~ COMMUNITY DATE DRILLED E} PUBLIC UTI LITY Connection Verified LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER []INDIVIDUAL/ON -SITE DATE INSTALLED E~PUBLIC UTILITY Connection Verified INSTALLER ~}Septic Tank or [] Holding Tank Size: _ If Tank is homemade SOILS RATING give dimensions: TYPE OF TANK MANUFACTURER TO~-AL ABSORPTION AREA MATERIAL 4. DISTANCESwELLTO: Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line AbS~rl)tio~ Area to nearest Lot Line 5, COMMENTS ~ APPROVED FOR BEDROOMS ~'UONDITIONAL APPROVAL (letter must accompany certificate) ~ DISAPPROVED 72 O10 (Rev, 6/79)