Loading...
HomeMy WebLinkAboutTERI #2 LT 2 of : cho 'agc Department of Health and Human Services 825 'L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 October 31, 1996 Alaska Eastern Partners Alaska Eastern, Inc. PO Box 240367 Anchorage, Alaska 99524 0367 Subject: Lot 2 Ter:L Subdivision #2 Permit #SW950367, PID #050-751-25 The subject permit, issued October 31, 1995 by this office for a single family well and/or on-site wastewater system, has expired as of October 31, 1996. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. If you have drilled the well, a well log must be sent to this office for documentation of the installation and to close the permit. If a licensed Professional Engineer has inspected the installation of the on-site wastewater system, the original as-built inspection report must be sent to this office for review, approval and documentation. Ail inspection reports must be submitted within 30 days of construction completion. When applying for a new permit, the fees are: $320.00 for an on-site wastewater permit; $120.00 for a well permit and $440.00 for a combined on-site wastewater and well permit. If you have any questions, please call this office at 343-4744. SincJrely, P~ogram Manager On-site Services enc: Copy of Permit cc: S & S Engineering PAGE 1 OF 1 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW950367 DESIGN ENGINEER:S & S ENGINEERING OWNER NAME:PIERSON JOHN 50% & OWNER ADDRESS:2402 EAGLE RIVER ROAD EAGLE RIVER, ALASKA 99577 DATE ISSUED:10/31/95 EXPIRATION DATE:10/31/96 PARCEL ID:05075125 LEGAL DESCRIPTION: TERI #2 LT 2 LOT SIZE: 93785 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAACS0) . 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: DATE: DATE: ROBERTC. COWAN, RE. ROBERTA. SHAFER, RE. SEWER&WATER MAIN ~(TENSIONS SEWER&WATER INSPECTION ENGINEERINGSTUDIES AND REPORTS WELL INSPECTION & FLOWTEST SITE PLANS ROA~ DESIGN SOILTEST PERCOLATION TEST STRUCTURAL & MECHANICAL INSPECTIONS October 23, 1995 CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 MUNICIPALITY OF ANCHORAGE Department of Health and Human Services P.O. Box 196650 Anchorage, AK. 99519 REFERENCE: Lot 2, Teri Subdivision Request you issue a permit to drill a well and install a septic system to serve the existing three bedroom house on the referenced property. A test hole was excavated and percolation test performed. The approximate location of the test hole is located on the attached site plan. At the time of excavation no water was encountered in the test hole and after seven day ground water monitoring, the monitoring tube was found to be dry. This property has enough area for a future septic upgrade which can be seen on the attached site plan. We do not anticipate any adverse effects on neighboring wells, septic systems or drainage patterns by the installation of the proposed septic system. There are no points of contamination within the proposed well radius which can be seen on the attached site plan. If you require additional information, please contact us. Sincerely, Robert C. Cowant RCC/gk PoEo Enclosure 17034 NORTH EAGLE RIVER LOOP · SUITE 204 o EAGLE RIVER, ALASKA 99577 ,50' SITE PLAN UPGRADE ~/ / ~ , m x C) _Lo 0 2u~ <-- r_-_Em z PERFORMED FOR: Municipality of Anchorage DEPARTMENT OF HEAL'¥H & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PEFICOLATION TEST LEGAL DESCRIPTION:~ '~' ~"~¢-\ ~'~:~ ~-~"- 1 2 3 5 6 7 8 9 10 11 12 13 14- 15- 16- 17- 18- 19- 20- ...... %'~.;,~. cE- 880 DATE PERFORMED~; ,~O.~,;~5 ,,", Township, Range, Section: SLOPE SITE PLAN WAS GROUND WATER ~. ENCOUNTERED? O IF YES, AT WHAT F~[ I~ DEPTH? ~ pO E Depth ID Waler Aller Mofliloring? ~'¢'~ Dale: co -7'5 -fi~- Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE ~ (mmutes/mch) PERC HOLE DIAMETER __ TEST RUN BETWEEN ~' ~--- FT AND ~ FT COMMENTS PERFORMED BY: 1 ~'0~4 [a~l- I~IvAp ! ~._~ ~.-~ ,~,~,, ~04 ~-'~''~ ~ ~J p CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCEW THALL~TA~EA~D ~I~GU D~L NESIN EFFECT ON THIS DATE. DATE: 72-008 (Rev. 4/85) SEWER & WATER M~IN EXTENSIONS ENGINEERINGSTUDIES AND REPORTS WELL INSPECTION & FLOW TEST ROAD OESIGN SOILTEST PERCOLATION TEST STRUCTURAL& MECHANICAL INSPECTIONS meemnq ROBERT C. COWAN, RE. ROBERTA. SHAFER, RE. ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES and MATERIAL SPECIFICATIONS CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 REFERENCE: Lot 2, Teri Subdivision ~t2 October 23, 1995 GENERAL: 1. t The scope of this project includes the installation of a 1000 gallon septic tank and five foot wide drainfield to serve the existing three bedroom residence for the referenced property. The existing outhouse is to be abandoned completely. Construction shall be in accordance with the approved site plan and design drawings, Municipal permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The contractor shall be responsible for obtaining any necessary underground utility locates. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. On all leachfield mound systems, the property owner shall be responsible for ensuring a satisfactory vegetation growth over the mounded area. Contractors installing wastewater disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval from the Municipal Health Department. SEPTIC TANK INSTALLATION: A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 2. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 17034 NORTH EAGLE RIVER LOOP · SUITE 204 · EAGLE RIVER, ALASKA 99577 Page Two Lot 2, Teri Subdivision t12 October 23, 1995 All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. Septic tanks installed with less than 4 ft. of cover shall be insulated. A foundation clsanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. ABSORPTION TRENCH/DRAINFIELD INSTALLATION: Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls cf the excavation become smeared, they must be raked or scratched (ruffed-up) before grave]. (sewer rock) placement. Once the gravel is installed, the distribution pipe is to be installed level with the perforations faced downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. Monitor tubes shall be of four (4) inch diameter, installed approximately in the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. Page Three Lot 2, Teri October 23, Subdivision ~2 1995 Backfill over the final gravel layer must not be less than twenty-four (24) inches· Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. MINIMUM MATERIAL SPECIFICATIONS: Any septic tank proposed for installation must be constructed by a Municipally approved septic tank manufacturer. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Type of Pipe Perforated Solid Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (HDPE) Yes No ASTM D2662 (ABS) Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. Ail leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the II200 sieve. When sand is being used as a filter material, its gradation specifications must conform to current M.O.A· or D.E.C. requirements. Page Four Lot 2, Teri Subdivision ~2 October 23, 1995 INSPECTIONS: Typically 'there will be a minimum of three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement of any other backfill. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required° Especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre-construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractors activities. The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above 'to document the contractors activities. Final acceptance of the contractors work rests with the owner and the M.O.A. S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineerlng's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOR/OWNER