Loading...
HomeMy WebLinkAboutTHAYERMOORE HEIGHTS BLK 2 LT 3Thayermoore Heights Block 2 Lot 3 #015-081-17 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On-Site Water & Wastewater Section Fax: 907-343-7997 Pump Installation Log Well Drilling Permit Number: _______________ Date of Issue: ____-____-____ Parcel Identification Number: ____-____-____ Legal Description Block Lot Property Owner Name & Address: Pump Installation Date: _____-_____-_____ Pump Intake Depth Below Top of Well Casing: __________ feet Pump Manufacturer’s Name: ___________________________ Pump Model: _____________________________________ Pump Size: ____________hp Pitless Adapter Burial Depth: _________ feet Pitless Adapter Manufacturer’s Name: _________________________ Pitless Adapter Installer: ____________________________ Well Disinfected Upon Completion? XX Yes No Method of Disinfection: _____________________________ Comments: Pump Installer Name: __________________________________ Company: ___________________________________________ Mailing Address: ______________________________________ City: ___________________ State: __________Zip: _________ Attention: The pump installer shall provide a pump installation log to On-site within 30 days of pump installation. Municipality of Anchorage - •. Development Services DepartmentQ- r' Building Safety Division OnSfte Water and Wastewater Program, 4700 S. Bragaw St. P.O. Box 196650 Anchorage. AK 99519-6650 Page of www.d.anchorage.skus (907) 343.7904 ONSRE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW060024 PID Number: 015-081-17 Remy James & Linda Von Bose Wastewater System: ❑ New El Upgrade 7230 Thayer Circle °�"` ABSORPTION FIELD Rumor a Beamamr 3 C3 DIOPTrwctr El atnrow Tnrce❑eea ❑t,m Mounter LEGAL DESCRIPTION Sol Rat" 0.8 Tab D"MNm nj�i�• 9 eyycn 2 wt 3 Thayennoore HIS GmFY3.5 D.Pm m aP. eamen m m a q �i oma. R. G^m 0-pa,b—m Pa. Townavp; Reaps eamorc W 2.412.4 E Fl. W 1.011.0 E Pt Fe egiE etnve on" pal Gila Lwvn wo.5h0.1E R. 2x50=1100 Well: ❑ New ❑Upgrade ornawYm: 5 n. Rumlrar ee peY ce rarwlnaRe Culnornn (R % ti e. cP Taa De Pa Gla b' R TanlWlrglan erect 2 12 R RP* Yepaat OreYv Deft Drava R SYa We*,t t anteater 675 PVC Del nmla v"'a A+ Home Services June 2, 2006 Ransera. algtiognt Pov.Gmu.aR GPM a• Ft. TANK SEPARATION DISTANCES ❑SePflc ❑ Holding Q S.T.E.P. E] Other To Septic ADso hon LIR 9 ieFrNwe From Tank Fkld Station Tank sewvuna ly Y� e�1e1 Anchorage Tank 1250 Gel Wall 101' 124' 110' N/A 72' meant Steel NinOifpCpi'w'ea."" 2 100'+ 100'+ 100'+ N/A LIFT STATION Lot late 39' 11' 45' WA ,e 1250 Get a 1ef Anchorage Tank & Welding Pwaatan 29' 38' 38' N/A 1'umP aa•raa vumPar Yva et "qn wew eWmer 32 n 22 n 36 h cmoin wan N/A N/A N/A N/A PunP Yee a Yoaa EMteKN knpayane ", nw ter 0°120 MOA Remeaat BENCH MARK Locemn Yq Decnpua. Northwest comer of back deck. mesawoa. 100.00 F` h,�P inspections performed by: Cindy W. Ellis .r 5/30/2006 * �9 9E••>& Dates: 1 ' .2nd 5/31112006 Development Services Department pproval�; Cl dy W Ellis :: Reviewed and approved by �_ 12.OG CE•too" f O e Date: .tool r 4 5,12°p249"V� FCO 3 BR lloox I Dcck Deck N>>°4.52j'W 186 07 A B FCO 10.2 42.9 STI 32.6 51.4 ST2 39.0 53.5 LS 41.2 54.6 C01 40.3 74.9 CO2 73.7 79.0 MT1 73.6 70.2 MT2 74.8 39.4 MT3 88.0 73.7 MT4 102.5 64.4 5,12°p249"V� FCO 3 BR lloox I Dcck Deck N>>°4.52j'W 186 07 AS -BUILT Thayermoore Heights Bik 2 Lot 3 Record Drawing Ohm I \1 o � s� Linda &James Von Bose Parcel col exist location of 1981 ID: 015.081.17 trench is unknown. Permit No. SW060024 0 0.:..... Cindy W. Ellis, RE P.O. Box 110443 ISTI / Anchorage, Alaska 99511-0443 �0�•,• •............... Scale 1 Inch - 30 R Phone: (907) 349-1851, Fax: (907) 349-1934 S z MT / MT3 TH hflZ / AS -BUILT Thayermoore Heights Bik 2 Lot 3 Record Drawing �o4OF q 4 �a.•• ••••••4q �4 of Septic Upgrade o � s� Linda &James Von Bose Parcel Watkins Engineering, Inc 9 9' °o !4 ID: 015.081.17 49 TH• Permit No. SW060024 0 0.:..... Cindy W. Ellis, RE P.O. Box 110443 S CI Y WOs� ELLIS p• '. June 8, 2006 Anchorage, Alaska 99511-0443 �0�•,• •............... Scale 1 Inch - 30 R Phone: (907) 349-1851, Fax: (907) 349-1934 �Ctpo FCO ST1 FINAL GRADE = 89.16 STEEL STEP TANK 1250 GALLON MT1 FINAL GRADE = 100.65-101.46 Filter Fabric + Insulation 111 SEWER ROCK 97.38 97.57 50.0' — West Trench 100.11 100.28 98.53 98.38 MT2 FINAL GRADE = 103.59 -103.71 MT4 101.26 Filter Fabric + Insulation To 1981 Trench NOTE: ORIGINAL GRADE 100.78 -100.88 NOTE: RELATIVE DEPTII OF TEST IIOLE = 82.88 NO NATER NOTE: ORIGINAL GRADE 103.46 -103.61 NOTE: RELATIVE DEPTII OF SEWER ROCK 101.11 TEST HOLE = 85.61 NO HATER East Trench 50.0' AS -BUILT Thayermoore Heights Blk 2 Lot 3Septic Record Drawing o �� ....OF Parcel ID90 5e 81-17 Watkins Engineering, InC. �p0o f9�0� Permit No. SW060024 Grid # 2439 00��?49TH O e . '.• ,..... 0 ......•._... • 0 .l.11�.. .. . *,cl DV W. ELLis 0o-; . E - ,0577......- : o Cindy W. Ellis, P.E. P.O. Box 110443 June 6, 2006 Anchorage, Alaska 99511-0443 00•,• ' •.•1 - � No Scale Phone: (907) 349-1851, Fax: (907) 349-1934e�Op...... oo EDS ELECTRIC INC 907 272 4590 06/06/06 07t S2pn P. 001 From +19078308507 Tu• Sun 6 04:30:36 20OG Page 1 of 1 INSPECTION REPORT MUNICIPALITY OF ANCHORAGE, BUILDING SAFETY DIVISION 4700 SOUTH BRAGAW INSPECTION INFORMATION &HELP: 343-7982 INSPECTION: VOICE 343-8300 INSPECTION: FAX (907)249-7777 ww .munl.org/BSDAnspecfl n .cfm NAME: n PERMIT Y: 06-7977 COMPANY: ED'S ELECTRIC - INSPECT DATE: 6/7/2006 PHONE C 272-4591 PHONE M: PHONE #: ADDRESS: 7230 THAYER CIR LOT 3 BLOCK 2 SUBDIVISION: THAYERMOORE HEIGHTS GRID 0: SW2439 COMMENTS or DIRECTIONS AM CALL FOR MEET ON SITE TYPE OF INSPECTION: final Electrical COMMENTS: (FOR INSPECTOR USE ONLY) PRINTED NAME .1•� •t• -= DATE: ': '�/• : �' /•�• MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Feb 22, 2006 Expiration Date: Feb 22, 2007 Permit Number: SW060024 Parcel ID: 015-081-17 Legal Description: THAYERMOORE HEIGHTS BLK 2 LT 3 Design Engineer: 0844 WATKINS ENGINEERING Site Address: 007230 THAYER CIR Owner Name: JAMES & LINDA VON BOSE Lot Size: 18800 SO. FT. Owner Address: 7230 THAYER CIR Total Bedrooms: 3 Permit Bedrooms: 3 ANCHORAGE. AK 99516-6554 This permit is for the construction of: 0 Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specked in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By. Date: _7 _Z_— d(o Issued By. TI I� – Date: Municipality of Anchorage WSZ44 P.O.IloxIIXWiO-Anchony:c,AhGslut9'ki19-(,rZO-Tcicphooc(907)313-MI-Paz(9(7), -9- M00 47110 BntkNw Sheet - Anchomgc, Alaska 99507 winv.muni.org Mayor Mark Begic/t Building Snfci}• Dii3sion February 22, 2006 Cindy Ellis Watkins Engineering P.O. Box 110443 Anchorage, Alaska 99511 Subject: Waiver Request for Thayermoore Heights Block 2 Lot 3 Waiver Request WR#: 060004 Parcel ID # 015-081-17 PERMIT # SW060024 Dear Cindy Ellis: Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 0.0 feet. 0' lot line waiver from existing septic absorbtion field to north property line. This waiver approval applies to the existing absorption field to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-7904. Sincerely, oodall Civil Engineer On -Site Water & Wastewater Program Comnlunity, Security, Prosperity Municipality of Anchorage Development Services Department Building Safoy Division On-Sitc Wetcr and Wastcwatcr Program 4700 Bragaw Strcct P.O. Box 196650 Anchoragc, AK 99519-6650 www.ci.anchoragc.ak.us (907)343-7904 Waiver Review Worksheet WR#: 060004 PID#: 015-081-17 HA1Permit# PERMIT # SW060024 Date Received: February 22, 2006 Legal Description: Thayermoore heights Block 2 Lot 3 Engineer. Cindy Ellis Watkins Engineering P.O. Boz 110443 Anchorage, Alaska 99511 Applicant: JAMES VON BOSE Waiver Requested: 0' LOT LINE WAIVER FROM EXISTING SEPTIC TO NORTH PROPERTY LINE Criteria: Geology Points: A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation Total: ...........................................................some.......... Waiver Is Granted: X List Conditions or Reasons for above: Waiver Is not Granted., Date: By: Joe Goodall Name of Reviewer ..................................................................... see. Rec#: Amount: $ Date Paid: 2/22/2006 Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 www.muni.org/onsite (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 015-081-17 Property owner(s) James & Linda von Bose Day phone Mailing address 7230 Thayer Circle, Anchorage Zip Code 99516 Site address same Zip Code Legal description (Sub'd., Block & Lot) Thayermoore Heights, Block 2, Lot 3 Legal description (Township, Range & Section) Lot Size 18,800 Sq. Ft. THIS APPLICATION IS FOR (® all that apply): Absorption Field Q Septic Tank Q Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ Number of Bedrooms 3 THIS APPLICATION IS AN: Initial ❑ Upgrade Q Renewal ❑ I certify that the above information is correct I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. IVN_�V,PE. (Signature of propeHy owner or authorized agent) PermMush Fees: 100 Waiver Fees: Date of Payment: Date of Payment: Receipt Number. Receipt Number. (Rev. 1 U05) I 30,13-51 Watkins Engineering, Inc. RO Box 110443, Anchorage, AK 99511 (907)349-1851 cwellis@gci.net February 21, 2006 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 RE: Thayermoore Heights, Block 2, Lot 3 Proposed Septic System Upgrade To Whom It May Concern: Attached please find the application and supporting documentation to upgrade the septic system for the referenced 3 bedroom house. The original septic system was installed in 1981, and the drainfield is now surcharged. It is proposed to retain the old drainfield and abandon the septic tank in place. The proposed design is based upon a test hole dug on February 7, 2006. The hole was dug to 18 ft with no water encountered. After a 7 day monitoring period, no water was detected. The proposed shallow trench drainfield will be installed in a silty sand layer between 2.5 ft and 5.5 ft. A percolation test between 3.5 ft and 4 ft resulted in a rate of 12 minutes per inch. The underlying silt layer had a percolation rate of 80 minutes per inch. An application rate of 0.8 gpd/ft' is used in the design. The soil log is attached. Proposed Soil Absorption System: 3 Bedrooms x 150 GPD/BR = System Type: Application rate: 450 GPD / 0.8 gpd/ft2 = Maximum Depth: Effective Depth: Reduction Factor: Proposed Length: Absorption Area: 450 GPD Shallow trench 0.8 gpd/ fl? 563 fP required 3.5 ft 1.0 ft 0.87 100 ft (240) 575 fP Sewer Upgrade Permit Application for Thayermoore Hts Blk 2 Lot 3 Watkins Engineering, Inc.; February 21, 2006; page 2 There are no surface waters or private wells within 100 ft of the proposed septic system. There are no slope concerns. A lot line waiver is requested for the old drainfield, to 0.1 ft from the north lot line. The drainfield was installed in 1981. I am not aware of any adverse effect that this upgrade or the lot line waiver would have on any adjacent properties' water and wastewater treatment needs. Thank you for consideration of this permit application. If you have any questions or need further information, please call me at 349-1851. Yours truly, Cindy W. Ellis, P.E. President Test Hole 217/06 ML 2.5 pero rate 12 minfin SM a.s 5.5 Proposed Trenches 1.25" pipe wt 0.25" holes 24" OC 1.0 It sewer rock Well radius, east easement line and south property line to be marked by a registered land surveyor prior to construction. DESIGN DETAILS 3 BR, 450 GPD 0.8 gpd/ft2 Requires 563 ft2 Shallow Trench 1.0 ft effective Reduction Factor 0.87 100 ft long Max 3.5 ft deep Thayermoore Heights Blk 2 Lot 3 Proposed Septic Upgrade Design Linda & James Von Bose Parcel ID: 015-081-17 Grid 2439 Cindy W. Ellis, P.E. February 21, 2006 Scale 1 Inch - 30 ft rMT ♦ o,Om Proposed Trenches (2) 50'long, 1'ef., 3.5'deep, ML 1.250PVC w/0.25'holes o S4GP� No Water BOH G�O�CO�'G 18.0 e�O e�Pc eo I m ro 1000 gal steel septic tan k-\ to be abandoned in place. b Proposed �J well 1250 gat STEP tank 7230 I Thayer Circle Existing MT 3BR House / Driveway / / qTH/ MT DESIGN DETAILS 3 BR, 450 GPD 0.8 gpd/ft2 Requires 563 ft2 Shallow Trench 1.0 ft effective Reduction Factor 0.87 100 ft long Max 3.5 ft deep Thayermoore Heights Blk 2 Lot 3 Proposed Septic Upgrade Design Linda & James Von Bose Parcel ID: 015-081-17 Grid 2439 Cindy W. Ellis, P.E. February 21, 2006 Scale 1 Inch - 30 ft rMT ♦ o,Om Proposed Trenches (2) 50'long, 1'ef., 3.5'deep, ° 1.250PVC w/0.25'holes 24" On Center. Minimum 3'soil cover. QF•Ac, Watkins Engineering, Inc. o .......TH " P.O. Box 110443 Anchorage, Alaska 99511-0443 Phone: (907) 349-1851, Fax: (907) 349-1934 �t 10577 a 1A ► IC ► i 1 B 10'x 30' CFA Emt 1 �I e� ► c� I / / Existing Existing Septic Syst well , 36R Hous well ell Of wen I / 1 HAYF k �� � I Proporse`a( Septic Syst m \ — Or / 2 \ / ► 5 / _ � I I _ I septic area (I I well I\ 100' radius Thayermoo a Heights Bloc 2 4 Approximate well location Thay rmoore Heights, BIOck\ / ► / ► I — — —� well/ — I I _ _ — \ I 20-00' Anchor Esmt \ I Thayermoore Heights. Block I � ► �aF i vim, 1 10 4 �RC3 \�� UUL� ► 5 5 4 II Thayermoore Heights Bilk 2 Lot 3 tic Bose ade Site Plan es *oo����op ...rj UnProda & Jamosed Von Watkins Engineering, Inc. Parcel 10: 015-081-17 �� �� ''�F' y �0 Grid 2439 TH p .../.49 - . .'.... Cindy W. Ellis RE P.O. Box 110443 Anchorage, AK 99511.0443 *CINlb " ,February .. 21, 2006 Phone: p �U•. Scale Y - 100' (907) 349-1851 Fax (907) 349-1934. •....••.....'oma pp•• .•o TO LOT 18 SEPTIC l TO LOT 1B WELL +100' TO PROP. LINE 1B I 1C INSTALL NEW 1000 CAL SEPTIC TANK. INSTALL DOUBLE CLEANOUTS AT OUTLET 1•M1•'L' a>'t nn 10' UTIL ESMi — _ 10' UTIL ESMT 'rte' _"��� —• ��—�\ 100 1.50 resro- 2 N N ao• C PROPO[EO TW EM" �\ \ RAOI(/$ S VE AREA SUM QUNCERNAE $LAO [i� 01.0 \ \ N. N0. 1 1 \\ / ®T ST HOLE pp ks-' 5 tP0\VoP*f �1 RPO\Jc� Ca .--- _L� THAYER CIR. NOTES: NO NEIGHBORING WELLS +100' NO SURFACE WATER +100' NO KNOWN CURTAIN DRAINS 3 OR > i 'I I > i I plo_. 3� � I� �I 1 � b 1 LOT 3 SEPTIC AREA J SEPTIC SITE PLAN LEGAL: LOT 2, BLOCK 2 THAYERMOORE SUB. OWNER: ERIC PERSSON DATE: 10/02/96 SCALE: 1" = 40' BRENT P. EATON, P.E. 11835 SPYGLASS CIRCLE ANCHORAGE, AK 99515 PH. 229-3777 LEGEND 0 0 N + h w w 0 U F CL Lu En J WELL w TEST HOLE PROP. TRENCH DRAINFIELD O PROPOSED CLEANOUT (CO) • PROPOSED MONITOR TUBE DESIGN ONLY Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci anchorage all (907) 3437904 Soils Log - Percolation Test Performed For. Linda & James von Bose Date Performed: Febuary 7, 2006 Legal Description: Thayerinoore Heights, Blk 2 Lot 3 Township, Range, Section: Cir: WAS GROUND WATER Depth ENCOUNTERED? No Net Time (Feet) Or9ayjjC_5 IF YES, AT WHAT DEPTH? — L Depth to Wat" After 2_ ML E 2 2.5 3- 3.5 2.5 4- 5M 3:32 5- 6" - 3.5 2.5 4 5 5 6- 6" - 3.5 2.5 7- 8_ rA L 9- 10- It- 12- 13- Cir: WAS GROUND WATER Date ENCOUNTERED? No Net Time Depth to Water s IF YES, AT WHAT DEPTH? — L Depth to Wat" After D P atonhoring? None E Dale: 2-14-06 Reading Date Gross Time Net Time Depth to Water Net Drop 1 2/7/06 2:32 0 6" — 2 3:02 30 3.5 2.5 3 3:32 30 6" - 3.5 2.5 4 4:02 30 6" - 3.5 2.5 PERCOLATION RATE 12 (,milnhcn) PERC HOLE DIAMETER 6" TEST RUN BETWEEN 3.5 FT AND4.0 FT COMMENTS Presoak prior to test PERFORMED BY: Cindy Ellis/Rocky Trainor I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDE NES IN EFFECT ON THIS DATE. DATE: 1-11,06 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street • Anchorage, Alaska 99501 Telephone 264.4720 —' ONSITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME PHONE 33'3— SINEW ❑UPGRADE MAILING ADDRESS 9-137710 'e5- x LEGAL DESCRIPTION Lot f LOCATION i2 NO. OF BEDROOMS VY DISTANCE TO: Well O Absorp[ion area O Dwelling PERMIT NO. — �Q N~ Manufacturer Material No. of compartments Liq. capacity in gallons IF HOMEMADE: Inside length Width Liquid depth d Y JZ2 DISTANCE TO: Well Dwelling PERMIT NO. Manufacturer Material Liquid capacity in gatlons O W = DISTANCE TO: Well Foundation Ig Nearest lot line Z 5,241 PERMIT NO. —1a2 �2w � No. of lines Length of each line Total len th of lines Trench width inches Distance between fines Cf O Top of tile to finish grade/ Material beneath tile inches Total effective absorption area r f 2 W tl Length Width Depth PERMO. IT N a F Wd Type of crib Crib diameter Crib depth Total effective absorption area u' DISTANCE TO: Well Building foundation Nearest lot line J J Class Depth Driller Distance to lot line PERMIT NO. W i DISTANCE TO: Building foundation Sewer line Septic tank Absorption arm(s) OTHER - PIPE MATERIALS SOIL TEST RATING INSTALL R CL v EP REMARKS � E i in M APPROVED DATE LEGAL / 2viu[nev.3r781 11� z 2� $101d I H� d� 1 � Nj 'Pot ii al � � o: r+ 01 di ,� m o , a co }^ 1 O� 1 o. Y q 44 14 m >{!t q(� i >� i pV14 V 11dd >i cd i tall i IV, IQ to:r4 ily-IIS q� ltl ri >1, rl Cd n! o 'Q! C1 1 m rl m I .4 D: U r I >I gni m F; m i +++ m m:v 1 a+. oo i a,': m $4 m! m E. 'v 1+ i PI m wl e� of l c0 03 .4 .-1;0 o,Im S at: 1.1 o s ,4: F! i m: m+v i b1 b f.+ # i N N N j 07: ; CVi 0] , %O i O 1 l� i O vl C.- co ; O� ii .-1pp1 i ! + CO' .�• n. d 1 W O�•'+ N' NiVkj Nj COi t8£Tbb£ W3nR 11"nv IJ.1 «cT>m #i r{ � Nj 'Pot W � � v a co }^ 1 O� 1 o. Y q 44 14 m >{!t q(� i >� i pV14 V 11dd >i cd i tall i IV, IQ to:r4 ily-IIS q� ltl ri >1, rl Cd n! o 'Q! C1 1 m rl m I .4 D: U r I >I gni m F; m i +++ m m:v 1 a+. oo i a,': m $4 m! m E. 'v 1+ i PI m wl e� of l c0 03 .4 .-1;0 o,Im S at: 1.1 o s ,4: F! i m: m+v i b1 b f.+ # i N N N j 07: ; CVi 0] , %O i O 1 l� i O vl C.- co ; O� ii .-1pp1 i ! + CO' .�• n. d 1 W O�•'+ N' NiVkj Nj COi t8£Tbb£ W3nR 11"nv IJ.1 «cT>m #i r{ • -- —� DATE RECEIVED -- INSPECTION APPOINTMENTS 6. TYPE OF RESIDENCE T I PTE TIME TIME _ ❑ Two ❑ Five - ❑ MULTIPLE FAMILY DAOTE DATE �� � - DATE 1 / - 1 =L I--ll=-zaf INSPECTOR -- INSPECTOR-l� INSPECTOR,,.-._ -- since June 1975. For wells drilled prior to that date, give well MUNICIPALITY OF ANCHORAGE MM�� ICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECYIObb,T. OF HEALft1 & - 825 L Street - Anchorage, Alaska 99501 - EhIVIRONMENTAL PROTECUON ENVIRONMENTAL SANITATION DIVISION Nr)v ?, Q 1981. Telephone 264-4720 REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND AZEb�aV- fl.9 ®C7 F �N DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for prod 1. PROPERTYOWNER MAILI GADDFI `l �O ��o� v��, qj( b� PROPERTY RESIDENT (if different from above)-- - PHONE 2. BUYER - 1 PI 0 INE— — MAILINGADDRESS - 3. L--��IIE'^N��'�D�ING INSTITUTION II PHONE c' MAILING ADDRESS 4. REALTOR/AGENT V PHONE —,N�— - MAILING ADDRESS - - 5. LEGAL DESCRIPTION - --- - - - 1,,-�-�- C jA STREET LOCATION 6. TYPE OF RESIDENCE _ NUMBER OF,BEDROOMS SINGLE FAMILY 1:1 One ❑ Four Ell Other _ ❑ Two ❑ Five - ❑ MULTIPLE FAMILY Three ❑ Six 7. WATER SUPPLY - ----- [ INDIVIDUAL* * ATTACH WELL LOG. A well log is required for all wells drilled - ❑ COMMUNITY since June 1975. For wells drilled prior to that date, give well ❑ PUBLIC UTILITY depth (attach log if available.) ------- 8. SEWAGE DISPOSAL SYSTEM --- —-- �] INDIVIDUAL/ON-SITE** ``��,,�� �- ` _YEAR ON-SITE SYSTEM WAS INSTALLED. ❑ PUBLIC UTILITY NOTE:TINSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. e 72-010 (Rev. 6/79) THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE ❑ SINGLE FAMILY ❑ MULTIPLEFAMILY NUMBER OF BEDROOMS ❑ ONE ❑ THREE ❑ FIVE ❑ OTHER ❑ TWO ❑ FOUR ❑ SIX 2. WATER SUPPLY ❑ INDIVIDUAL ❑ COMMUNITY ❑ PUBLIC UTILITY Connection Verified PERMIT NUMBER DEPTH OF WELL DATE DRILLED LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM ❑INDIVIDUAL/ON -SITE ED PUBLIC UTI LITY Connection Verified PERMIT NUMBER DATEINSTALLED (( INSTALLER ❑Septic Tank or ❑Holding Tank Size: 1 0 If Tank is homemade give dimensions: SOILS RATING TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL <'- 1 4. DISTANCES WELL TO: Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line 5. COMMENTS '1O�APPROVED FOR - BEDROOMS ❑ CONDITIONAL APPROVAL (letter must accompany certificate) ❑ DISAPPROVED 19 DATE BY 72-010 (Rev. 6/79) Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 995195650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 015.061-17 1. GENERAL INFORMATION I =' COSA#_N066.5-O Expiration Date: _ / — D 6. Complete legal description Thayermoore Heights, Block 2, Lot 3 Location (site address) 7230 Thayer Circle, Anchorage, AK 99516 Current Property owners) John Hale & Jodi Elliott Mailing address Lending agency Mailing address Real Estate Agent Mailing Address 7230 Thayer Cir., Anchorage, AK 99516 Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF 3. TYPE OF WATER SUPPLY: Individual Well ✓❑ Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ Day phone Day phone Day phone TYPE OF WASTEWATER DISPOSAL: Individual On-site 0 Individual Holding Tank ❑ Community On-site ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given In paragraph 4 by an independent professional civil engineer registered In the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also Issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineers work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my Investigation, based on procedures outlined In the Certificate of Onsite Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. l further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and Inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Finn Watkins Engineering, Inc. Phone 349-1851 Address PO Box 110443, Anchorage, AK 99511.0443 Engineer's Printed Name Cindy W. Ellis Date 6-7-2006 0 5. DSD SIGNATURE * W. Ellis l% Approved for _� bedrooms. CE -torn Disapproved. ssror ri Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other By: az Original Certificate Date: (R«. IM) . � }�\ §| !§ ! |)( E § .9L-69 t &=•*mo Ng - \■ } _TY CASEMENT\ | M w — — — — — — — — — — — — — — — — ;v�_ ., -------------------- § lz=, .>.� . " \\2I . |;|. . . g|! 9d|Z# \) §|§ § (I |�)� E� - \ ' §2 § ' J \ |§ ®----------- Ad, * \ �( fNo E u -CV / |r % _ m a §§ �� ) / / | 2 E! ®| §, ||® i�i"oz §§ I'm'Fo-� |,! L . s,., e |»- § | .|_ M § 2|| �o % /,E /- w� /§ g!E h! |�� » § §o (®�ZWI} I | . u \ Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 1%650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 015-061-17 1. GENERAL INFORMATION COSA # CIP 006 1) Expiration Date: 6'-- a ,2,- d C, Complete legal description Thayermoore Heights, Blk 2, Lot 3 Location (site address) 7230 Thayer Circle, Anchorage, AK 99516 Current Property owner(s) James & Unda von Bose Day phone Mailing address Lending agency Mailing address Real Estate Agent Mailing Address same as above Homestate Mortgage Day phone Rob Delucia / Prudential Day phone Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: Individual Well r❑ Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ TYPE OF WASTEWATER DISPOSAL: Individual On-site o❑ Individual Holding Tank ❑ Community On-site ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered In the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of Issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage Is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined In the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system Is (are) safe, functional and adequate forthe number of bedrooms and type of structure Indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my Investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) In compliance with all applicable Municipal and State codes, ordinances, and regulations In effect at the time of installation. Name of Finn Watkins Engineering, Inc. Address P.O. Box 111443, Anchorage, AK 99511 Phone 349-1851 Engineer's Printed Name Cindy W. Ellis Date 2121106 5. DSD SIGNATURE''ti Approved for bedrooms. CE -1057 ' Disapproved. 001'E _ Conditional approval for A bedrooms, with the following stipulations: Money to be escrowed in the amount of $ 23.555. to construct a new wastewater disposal Ustem including engineering and surveying pursuant to permit number SWO60024 Money in escrow shall not be released until this office has given final approval. Construction shall be completed no later than June 15, 2006. Attachments: COSA ChecIdist X Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report X Other By: Original Certificate Date: V— -.;L:z - 0 G (Rw. 11106) Municipality of Anchorage Development Services Department Building Safety Dlvlsion Or -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 198850 Anchorage, AK 99519.8850 www.muni.org/onske (907) 943-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: 1 ►1 al 4r wle Ati�K4y gkZ (SPC3 PamellD: 015-081-17 A. WELL DATA Well type Prt If A, B, or C provide PWSID Date completed 919/81 Sanitary seal (Y/N) Yes Total depth 118 R. Cased to 12L_ft. FROM WELL LOG Date of test September 9, 1981 Static water level 61 R. Wall production 15 9 - p.m -WATER SAMPLE RESULTS: Coliform 0 cwlonies/100 mL Nitrate 424 nigh Arsenic: 0 mg/l Date of sample: 217108 S. SEPTICIHOLDING TANK DATA Tank Type/Matedal Steel Septic Tank Tank sae 1000 gal. Number of Compartments 2 Well Log (YM) Yes Wires property protected (Y/N) Yes Casing height (above ground) 22.5 in. AT INSPECTION Febuary 7, 2006 rt. 7.0 9 - p.m - Other bacteria 0 colonies/100 ml Collected by: Rocky Trainor Date installed September 1981 Cleanouts (YIN) Yes Foundation cleanout (Y" Yes Depression over tank (YM) No High water alar (YIN) N/A Date of pumping NA Pumper NA - Septic failed C. ABSORPTION FIELD DATA Date inslatied 9/1981 609 rating (g.p.dJf? orfelbdmo275 System type deep trench Length 75 rt. Width 8 rt. Gravel below pipe 5 R. Total depth 10 R. Eff. absorption area 1350 ftp Monitoring tube __Y Depression over Heid No Date of adequacy test 1/10/2008 Results (Pass/Fa10 Failed For 3 bedrooms Fluid depth In absorption #aid before test 70 in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth kr. Absorption rate >- g.p.d. Any rejuvenation treatment (past 12 mo.) (YM 3 type) If yes, give date D. LIFT STATION Date instaued N, Size in gallons Manhole/Access (YM) 'Pump on' level at _ in. •Pump ofr level at _ in. High water alar level at in. Datum Cycles tested Masts alarm b circuit rwMremerrts9 E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank= station on lot 100.9' On adjacent lots 100'+ Absorption field on lot 101.5' Public sewer main 100+ Sewer /septic service line ±r On adjacent lots 100'+ Public sewer manhole/cleanout 100+ Holding tank N/A Animal containment areas 100'+ Manure/animal excrete storage areas I W+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 32.3' Property line 27•7' Absorption field 1' Water main 100+ Water service line 50+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 0.1' Building foundation 30+ Water main 100+ Water Service line 60+ Surface water 100'+ Driveway, paridng/vehide storage 80' Curtain drain NfA Wells on adjacent lots 100'+ F. COMMENTS: Conditional COSA requested. Septic system to be upgraded. Lot line waiver requested for 1981 drainBeld to north lot line. G. ENGINEER'S CERTIFICATION I car* that I have determined through geld lospecdons and review of Munidpel records that the above systems are in cOnftmance with MOA COSA yuldeUnes in eAbrx on this date. Engineer's Printed Name Cindy W. Ellis, P.E. COSA Fee S 4-10 • Gc� Date of Payment `�IJ1 64 Receipt Number qir ?moi (Rev. 11/05) lam Waiver Fee S ��•5 D� Date of Payment Receipt Number 9,qZ( Watkins Engineering, Inc. RO Box 110443, Anchorage, AK 99511 (907)349-1851 cwellis@gci.net February 21, 2006 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 RE: Thayermoore Heights, Block 2, Lot 3 Request for Conditional COSA Attention: Mr. Jeff Poet Dear Jeff, On behalf of the owners of the subject property, I am applying for a conditional Certificate of Onsite Approval for the existing 3 bedroom house. A permit application has been submitted to upgrade the septic system. The COSA checklist and water samples are attached. The proposed septic upgrade is based upon a test hole dug on February 7, 2006. The drainfield will be installed in a stratum between 2.5 ft and 3.5 ft. I request approval to install the septic system in the spring due to frost concerns. When the test hole was dug, there was frost down to about 2.5 ft. I am concerned that the stratum adjacent to the sewer rock could currently be frozen. The current septic system is functioning marginally. There is no evidence of sewage surfacing, although the drainfield is surcharged. I do not believe that delaying the installation of the septic system would cause any risk to human health or the environment. The new homeowner will need to be cautious to avoid overloading the system. Three bids have been obtained to install the septic system. The high bid is $14,920. Funds in the amount of 150% of this high bid will be put in escrow at closing for septic system installation. The installation will be performed as soon as possible in the spring, and prior to June 15, 2006. Conditional COSA Application for Thayermoore Hts Blk 2 Lot 3 Watkins Engineering, Inc.; February 21, 2006; page 2 Thank you for consideration of this application. If you have any questions or need further information, please call me at 349-1851. Yours truly, Cindy Ellis, P.E. President SCS Re[k 1060633001 All Dates/Times are Alaska Standard Thne Client Name Watkins Engineering Printed Date/Time 02202006 8:03 Project Named Water Samples Collected Date/Time 02/072006 14:00 Client Sample ID Thayermoore IIts Bk2 Lot3 Received Date/Tine 02/082006 11:45 Matrix Drinking Water Technical Director Stephen C. Ede PWSID 0 Sample Remarks: Arsenic ND 5.00 ug/L Parameter Results PQL Units Method Container ID Allowable Units Prep Analysis Date Date Init Nitratc-N 4.24 0.100 mgt EPA 353.2 B (< 10) 02/08,'06 )C Metals by ICP/MS Arsenic ND 5.00 ug/L EP200.8 C (<10) 02113/06 02/15/06 TK Microbiology Laboratory Total Coliform 0 col/100m], SMI -09222B A (�I) 02108106 TLF FROM : Denali Excavation PFMIE NO. : 3461388 Feb. 16 2OeG 05:21AM P1 MM2" EX C,:A 1,i4T 1 . N t P UNI#P I�IV L , L, 651 East 10e Avenue Phone (907) 346-3338 Anchorage, Alaska 99515 Fax (907) 346-1388 FAMILY OWNED AND OPERATED VISA AND MMTERCARD ACCEPTED I ima'and lames Von Bose 2116/2006 C/o Cindy Ellis - Waaam Engineering RE: Proposed septic upgrade for 7230 Thayer C =k The fonowing is a hump sum quote for the Proposed septic upgrade at 7230 Thayer Circle, as designed by Wattats Engineering. Inc, plans dated 2/13/06: Lump sum total gnmc — Installation before Junc IR S15 684.00 Lump sum tell quote—hrstanatim after June I". $14920.00 The above quotea include all oquipment, labor, a>pervidon, and materials to excame and install a new 1250 gallon STEP tank; two new leach field trenches totaling 1001mear feet; abandonment of existing tank; comariwi to a daft leach field; electrical connection: and backfill and grading ofimpaeted areas. Please note the following tondmons/eaclustons: • This quote does not kdude any import or mpott of soils or gravel beyond that which is required for the effecth-c depth of the leachtmIds Additional material can be imported or arporte , on a unit price basis at bomeavner's request. o This quote does not include any laodsamg, topsoil work, or sending of vupacaed areas: Said • . audceg4 be pe:formcd at homeowner's tegaest and experue. • This quote does mt include any surm)ing or fiaggirtg. • An allowance of $1100 Is included in these quotes for the electrical connection iap»re& Should circanutanoes roquire more than $1100 of electrical work. additional charges will be homeowner's responsibility. • SbouM��unforese n conditions warrant any variation in original design, additional charges will be • Unless otherwise VeciSed or agreed upon, payment is due in full upon completion and final inspection of work. If you have any qucslions, please feel free to call. Thank you for considering Dcaali Excavation for your project! Sincerely. clary L'- eggs [II rad-e1-eV4b 03:198 FROM: �vn TO:3491934 P:1�1 proposal Pogo No. of n A+ HOME SERVICES, INC. 7501 E. 140th Avenue Anchorage, Alaska 99516 (907)345-1890 a Fax(907)868-6770 PROPOSAL SUBMITTED TOPHONE DATEs e--�e}'�"F-mda=TaeBr-e `. ._3 0' WO hafty su l npO.tanOna anp sefim"M" ver. Ar Home Services, Inc- appreciates the opportunity to bid and Would be happy to envate and install a new 1250 gallon STEP. tank completely abandoning the earstmg septic took. To install a drainfiield that is 100 long and 3 5 deep lewAne the remaining drainf;dd as a future reserve site. To meet.A.LL er-gineem specificatians per design dated 2-14-06. WinterIndallatioa $17.690 Summer Installation S14'm If you have any questions or coacems, or would like a site visit, please do not hesitate to call our effete at the number listed above. We are not re-sponsible for underground Utilities unless located by the Locate Call Ceater or settlement over disturbed areas - tilt ;OropOSt hereby to furnish material and labor - complCtc In accordance with above spec fk ations, for the sum Of: PAYmoM to be made as fdlews. donars (S AI martens: b guaranteed b be PS SPWiad. NI work to be oemoieted in A worknunrke manrrr attmOing t0 standard praQiC01. Any OseraWn er dr,4 m from above vm!5- Authorized carkna A"OMng 0aea ooate wit: be eaaCUted omy upon w.ltten order", sno will Datums Signature _ an *Arra ehWge Over and 800" the sadmate. A/ agreements OOntingant upon Snik". ottidorts 0r duos e"ye"d 01 dpnUot. owner ro carry am, tomaoo. and our, ne i NOTE: TNs proposal may eerybekru n""e, our "kat ars busy ewa,ed by WOrkmen's Compnua*n erufaue withdrawn by US n not accepted within U clays. 2rapWllm of proposal —The above prices, specifications and con. — ddlons are aatisfaemry and are hereby accepted. You aro authorized to do Signature the work as specified. Payment wnl be made as ovtGnod above. Date of Accoptaneg: Signature -- .. -., r........ -1"0%0 VVNIMML I1NU INV. eme / Address Watkins Engineering Inc. P.O. Box 110443 Anch. Ak 99511-0433 749-1651 hm349-1934 N Job: Linda A James Yon Bose 907-868-1019 p,t PO Box 111373 z Anchorage, Alaska 99511.1373 907-242-9650 0 Fax 907-868.1019 Estimate Gate T Estimate fJ 2/17r200G227 Project Description Oty Rate Total Install new septic "em as per Watkins Engineering Inc. (this is 14,500.00 14,500.00 based on a standard tank and riser and access floor & neighbors yard to the north). Cost increase if done nen week 52300 (due to frozen ground) Exclusions Top soil, landscaping Deep burial tank and riser if needed Foam to cow field or tank if needed Total 614,500.00 1 Ae—Built" 1 hereby certify that a survey of the following descrlbed property LvT 3 P, o<r 2 if vEP was made on . and j �are vllhin the prapnrty Ilnns and do 'not that Overlapeormencroach nan the p opertyuatedrean adjacent thoroto,that no Improvements on property lying adjacent thereto encroach on the praminse In quention•and that there aro no roadways, transmission lines or other visible oassmants on sold property except. ea Indicated hereon. Oatod of Anchorage, Alaskathis /_7 day of pGT.. /4/�/ —`_, CONTRACTING ENGINEERS A ASSOC. 7J2 E. International Airport Road j Anchorage, Alaska 99502 ' Phone: 278-3773 1 Ca9e� . .........if;dq b.,......o•... u7 i.. %'. Donald O. Spur J �•, f+ a, .• NO 2233-S y4' e48 n�oressmnnL�a`�•ti , SEAL.'