Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
THE LANDINGS BLK 1 LT 8
Lo'r Municipality of Anchorage On -Site Water and Wastewater Section - (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP221444 PID Number: 020-061-15 Dwelling: H Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ❑® Upgrade Name C/O TIM MILLER ABSORPTION FIELD ❑ Deep Trench ❑ Wide Trench X Bed ❑ Mound Site Address 16145 WINDJAMMER CIRCLE, ANCHORAGE, AK ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 907-223-3438 3 **1.0 GPD/SF SEE DWG. Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade SEE DWG. Ft. Gravel depth beneath pipe 0.65 Ft. Subdivision Block Lot THE LANDINGS 1 8 Fill added above original grade SEE DWG. Ft. Gravel length 30 Ft. Township Range Section - - Gravel width 20 Ft. Beds: Number of Lines 6 Distance between lines 5 Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 600 FF - - Ft. Well *50'+ *50'+ *50'+ - 25'+ TANK © Septic N S.T.E.P. El Holding E] Other Manufacturer INFILTRATOR SYSTEMS Capacity 1060/540 Gal. Surface Water *50'+ *50'+ *50+ - Material Number of compartments Lot Line 5'+ 10'+ 5'+ - NA PLASTIC 2/1 Foundation 10'+ 10'+ 10'+ _ LIFT STATION Manufacturer Capacity Remarks `AWWTS. `*CAT III APPLICATION RATE USING INFILTRATOR/QUANICS 475 Gal. CAT II AEROCELL SYSTEM WITH 2 -FOOT SAND FILTER Alarm location INDOOR Electrical installed by M.O.A. Installer PIPE MATERIAL House to tank D3034 Tank to D3034/ drainfield D1785 ELEVATE CONSTRUCTION Drainfield D3034 COJMT D3034 Inspector GEG CONSULTANT, JODY MAUS BENCH MARK (Assumed elevation) 100.00 ft Inspeection iw 12/28/22 12/28/22 Location and description 2ud 3' 12/28/22 4u' 12/29/22 TOP OF CONCRETE RETAINING WALL NEAR FRONT ENTRY. ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineers S}amp Conditional Approval: Date oo6oO� 4. �..... e......... D . Septic System Approved Date l Z / 2 ef`- A. Ga ess. 0 1 y"�--- o 9 C -79 3 -• zp QprP '' �• t• �.Z�. Note: this include _o �4p0000 % 1=1 approvales not well permit requirements. �CCe knuv voivu ivj 01 PERMIT NUMBER: PARCEL ID NUMBER:ORCCR® DRAWING 020-061-15 I i i i NOTE: PER THE CONTRACTOR, THE OLD / SEPTIC TANK AND THE OLD LOG CRIB WERE DECOMMISSIONED PER UPC. NOTE: A LETTER OF NON -OBJECTION FROM THE UTILITY COMPANY HAS BEEN GRANTED FOR THE SEPTIC SYSTEM TO s9� BE WITHIN THE 40' ELECTRIC EASEMENT. O -BENCHMARK = TOP OF RETAINING WALL i RETAINING A WALL INSTALLED �+ DOUBLE ,. CLEANOUTS NEW IM -1060 INFILTRATOR \�� \+` (DBLI & DBL2)�% 3 LISTING \ DROOM TWO COMPARTMENT \ HOUSE i- SEPTIC TANK A B FCO 49.3 28.8 INSTALLED \ IPA % DBL1 59.1 57.7 DOUBLE DBL2 59.9 58.6 CLEANOUTS MHi 61.5 60.3 (DBL3 & DBL4) STI 66.6 65.8 NEW IM -540 Pa DBL3 67.9 63.5 INFILTRATOR PUMP DBL4 68.6 62.9 TANK WITH PUMP AND +Goy ` 1 WELL RADIUS MH2 71.0 61.1 QUANIGS CONTROLS Goa FOKAWWTS VP1 77.4 54.9 NEW A-400 AEROCELE On y \ POD1 80.1 55.2 UNIT (POD1 & POD2) POD2 76 0 i 497 G �. NEW DRAINFIELD— 0 0 \ �G Q NOTE: PIPE LOCATIONS ARE SHOWN PER GEG SHOTS TAKEN WITH LEICA DISTO S910 LASER DISTANCE METER. SWING TIES TO HOUSE CORNERS WERE GENERATED IN AUTOCAD. ' J / a mimialk It OF A IF Tp ..�.. 4 . .. .............10 . ENGINEERING o; SALES 0 CONSULTING 4 = 110- 3701 EAST TUDOR ROAD SURE 101 'ANCHORAGE, ALASKA' PHONE (907) 3376179' WEBSITE. www.gamenonginoenng.comrl ++r ...1,.+ ... . �y....r. 1^ • �•V PREPARED FOR: PHONE NUMBER: PAGE NUMBER: ®� e rey`Ay mess 4� Aw TIM MILLER 907-223-3438 2 OF 3 ®0� E-7 3� PROJECT/LEGAL DESCRIPTION: DRAWN BY: ®®®�I�I J'a �••.•' ���®V THE LANDINGS; BLOCK 1, LOT 8 DATJ. M ®4 �O p' , . ES® TYPE OF WORK: 4 ROFES � RECORD DRAWING OF SEPTIC SYSTEM UPGRADE 1!16/2023 #LI ENSCC8Ulkljljlk OSP221444 1"X C ka V M U U I'CH V V I jN U 020-061-15 FINAL GRADE = 96.62-96.71 SEE FINAL GRADE NOTE - TOP OF MH1 = 96.91 TOP OF TANK @ INLET = 94.61— INVERT OF INLET PIPE = 94.03— IM-1060 TWO COMPARTMENT INFILTRATOR SEPTIC TANK - -4" OF INSULATION (PER CONTRACTOR) -----� -a------------AA--------- FINAL GRADE NOTE: ADDITIONAL FINAL GRADING TO BE COMPLETED IN THE SPRING/SUMMER OF 2023. 1 TOP OF TANK @ OUTLET = 94.55 INVERT OF OUTLET PIPEINVERT OF = 93.83 INLET PIPE ="Rn— -TIMED DOSED CONTROLPANEL TOP OF MH1 = 97 TOP OF TANK @ INLET = QA R'A- IM -540 SINGLE COMPARTMENT INFILTRATOR PUMP TANK — INDOOR REMOTE ALARM NAL GRADE = 96.85 TOP OF 4" OF INSULATION TANK @ (PER CONTRACTOF OUTLET = QA Ri-, I I INVERT OF RETURN LINE PIPE = 93.75 *TIMER OVERRIDE FLOAT - 475 GALLONS CAPACITY WHEN FLOAT IS ACTIVATED. *HIGH WATER FLOAT - 455 GALLONS CAPACITY WHEN FLOAT IS ACTIVATED. *TIMER ENABLE FLOAT (ON/OFF) - 261 GALLONS CAPACITY WHEN FLOAT IS DEACTIVATED. GOULDS PE51 M EFFLUENT PUMP 4CRETE BLOCKS ,-400 AEROCELL UNIT TOP OF POD = 96.59 VP2 RETURN LINE 20% DISCHARGE TO DRAINFIELD PROPOSED PUMP TANK FLOAT SETTINGS INFILTRATOR TANK MODEL IM -540 TOTAL CAPACITY 552 GALLONS WORKING CAPACITY 475 GALLONS INLET INVERT 44" TIMER OVERRIDE FLOAT 34" *42" HIGH WATER ALARM 32" *40" TIMER ENABLE FLOAT 20'('28') FLOAT LEVELS ARE FROM BOTTOM OF PUMP (*MEASUREMENT FROM BOTTOM OF TANK). NOTE: MEASUREMENTS ARE WHERE THE FLOAT WIRE ATTACHES TO PIPING WITH A 3.5 INCH TETHER FROM PIPING TO FLOAT. WANGLE FLOATS. OJ U- w Q� ai- a 00 M d' co mM 2 CV :3 w0 Zrn a w ca M ?� ZO wch a m� Z-1 o CO - O 04 co uir 0 .�. 0, rey AGaress�®,A • •........ LICEN E 44 ®0 ME C884 1,4 z Z O� ow �g U? g wz -j= a. - w H Z O > U) Guy -j U .` Z. �~Y W ZN W; U O �w m O Z n oz D gir L.L wW 0 = 0O - LL LU 0 0~ aOf L CF �J o 3 ®.......... ........... ...® .�. 0, rey AGaress�®,A • •........ LICEN E 44 ®0 ME C884 \( 0 I \ paM@ § G ®\$» N ) awa$ p e k %\L § \ ®4/G m ure2 2a± ®sS9 k3% \\%/ PS uj \\\ m$§e z�% Sae$@o7$ \SmE[$@3 «m3«m@am %3§/m>9\ »go¥>a {E%o»3AE E\{ / $/E( {%2%>mK£ ))§�\)�\ ogmawe(s \ee>2mz %t o�a�a�� (6{ \O\ f +6,; w ya 2 \ \\\ \ C e E v \\ \± e% QZ Q . 3\Q , \§ \\\ \ \/ \ \\\ e \\ \ \\\\\ ®e \ /\%«\\ m «° \ Lij � % / rz \ LQ § &% « *Qj LLJ \ paM@ § G ®\$» N ) awa$ p e k %\L § \ ®4/G m ure2 2a± ®sS9 k3% \\%/ PS uj \\\ m$§e z�% Sae$@o7$ \SmE[$@3 «m3«m@am %3§/m>9\ »go¥>a {E%o»3AE E\{ / $/E( {%2%>mK£ ))§�\)�\ ogmawe(s \ee>2mz %t o�a�a�� ®$)# \O\ f +6,; paM@ § G ®\$» N ) awa$ p e k %\L § \ ®4/G m ure2 2a± ®sS9 k3% \\%/ PS uj \\\ m$§e z�% Sae$@o7$ \SmE[$@3 «m3«m@am %3§/m>9\ »go¥>a {E%o»3AE E\{ / $/E( {%2%>mK£ ))§�\)�\ ogmawe(s \ee>2mz %t o�a�a�� MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP221444 Work Type: Septic Upgrade Tax Code Number: 02006115000 Site Legal Address: THE LANDINGS BLK 1 LT 8 G:3235 Site Mailing Address: 16145 WINDJAMMER CIR, Anchorage Owner: MILLER ARVIN A& MARJORIE I Design Engineer: GARNESS ENGINEERING GROUP LTD This permit is for the construction of: Effective Date Expiration Date: Lot Size in Sq Ft: Total Bedrooms: ,yv�ent `fir. Department 11/23/2022 11/23/2023 28810 Q Disposal Field CEJ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing - iae By: -E ss cAe,_,i to r G,_ - Issued Issued By: Date: Date: 3 MUNICIPALITY OF ANCHORAGE Development Services Department `� _ ; Phone: 907-343-7904 On -Site Water & Wastewater Section -- Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 020-061-15 Property owner(s) C/O TIM MILLER Day phone 907-223-3438 Mailing address 16145 WINDJAMMER CIRCLE *ANCHORAGE, AK Site address 16145 WINDJAMMER CIRCLE *ANCHORAGE, AK Legal description (Sub'd., Block & Lot) THE LANDINGS; BLOCK 1, LOT 8 Legal description (Township, Range & Section) Lot Size Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field 0 Initial ❑ Single Family (SF) (`N/wo AD U) Septic Tank 0 Upgrade 0 (D) ❑ Holding Tank ❑ RenewalDuplex ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: 5-gS Date of Payment: o Receipt Number: G _�- �Z !1 `Z. Gj Permit No. a S2 2 Waiver Fees: Date of Payment: Receipt Number: Waiver No. GADevelopment Services\Building Safety\On Site Water and WastewaterTorms0lent FormsTermit Application.doc Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221444, Deb Wockenfuss, 11/23/22 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221444, Deb Wockenfuss, 11/23/22 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221444, Deb Wockenfuss, 11/23/22 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221444, Deb Wockenfuss, 11/23/22 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221444, Deb Wockenfuss, 11/23/22 MUNICIPALITY OF ANCHORAGE VANCED WASTEWATER TREATMENT SYSTE MAINTENANCE AND REPAIR AGREEMENT i THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEN,4ENT" made and entered into as of this 'Vc� Day of of 20 .22, by and bi etween herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advanced W I asteivater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as AV located at (legal description) /6AX 2. Maintenance; Repairs and Al (Owner is required to read, understand and initial each section) c7X4lY---- Throughout the term of this Agreement. the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septi effluent in accordance wii h the equipment's approval for operation in the Municipality. It shall be the responsibility of the Owner during the terra of this Agree?-ent to pay for all repair(s), mainienance, aqiustment(s), replacement costs, and inspection ;costs. This includes an annual maintenance fee (typically $400 to $600). Owner agrees that only maintenance and repair personnel approved by the Municipaliq or the manufacturer's representative will inspect and make any necessar}� maintenance, repairs or permitted alterations to the system. Owner acknowledgesI that regular maintenance of an AWWTS reduces tl�le potential failure of the system, which could include sewage backup and costly repairs or drainfileld replacement. (rev. 05/18/2018) Pagel of WIAL Owner acknowledges that the Municipality may request records of mat] repairs fromthemanufacturer's representative or maintenance providei Owner acknowledges that the fine for failing to maintain and repair an', assessed in accordance with AMC 14.60.030. Owner agrees to grant the Municipality reasonable access to test and id., AWWTS. The Municipality will give at least 24-hour notice. i Owner agrees that any sale or transfer of title of the property will not Certificate ofOn-Site Systems Approval. Owner agrees that the AWWTS installation and maintenance requireme by the AWWTS vendor/installer and approved by the Municipality are Ilt guidelines f6f, the construction, maintenance and repair of the Owner's Owner agrees; to maintain remote monitoring of the AWWTS as require( AWWTS approval. 3. Terni. The term of this Agreement shall begin on the date of approval b Municipality to operate the installed system., or upon transfer of title. all( -while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a pr 9 Agreement shall in no way constitute a waiver of the provisions. nor in a the validity of Agreement or any part hereof. or the right of the Mun thereafter to enforce every provision hereof. 5. Amendment. ,This Agreement shall only be amended by authorized repr the Owner and, Municipality. Any attempt to amend this agreement by e'i unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of La Any civil action arising from this Agreerri brought in the Superior Court for the Third Judicial District of the State 6 Anchorage. The laws of the State of Alaska shall govern the rights and 61 parties under this Agreement. 7. Severability. Any provisions of this Agreement decreed invalid by a cou jurisdiction shall not invalidate the remaining provisions of the Agreeme n (rev. 05/18/2018) and WWTS may be pect the without a new IS as provided ie governing WWTS. by the , the shall continue 'ision of this iy way affect ipality ;sentatives of her an �tlt shall be Alaska at ligations of the t of competent Page 2 of 3 Ow 0 (signature) Date: ll (print name) STATE OF ALASKA ) THIRD JUDICIAL DISTRICT ) ss. The foregoing instrument was acknowledged before me this,?,, of (�10 20,3D. by IitG11',�YI� �1'1� I1� r Nouvy NOTARY PUBLIC FOR ALASKAat81 a � toot My Commission expires: i�c 8 MUNICIPALITY: I By: (signature) Date: (print name) Title: (rev. 05/18/2018) 3 6e �- 2024 Page 3 of 3 zozz-oriels-o A Recording Dist: 301 - Anchorage s 11 /21/2022 08:35 AM Pages: 1 of 4 1103-04A Grid 3235 EN22037 020-061-15 ENCROACHMENT PERMIT This permit is between Chugach Electric Association, Inc., an Alaska non-profit electric cooperative (herein "Chugach"), whose address is P. O. Box 196300, Anchorage, Alaska 99519, and Arvin A. Miller and Marjorie 1. Miller (herein "Permittee"), whose address is 16145 Windjammer Circle, Anchorage, Alaska 99516. 1. Easement. Chugach is the grantee or user of an easement for the construction and maintenance of electrical facilities, as follows: Dedicated by the plat of the subdivision known as The Landings Subdivision, according to Plat Number 69-37, recorded on the 2nd day of April 1969, on file in the office of the District Recorder, Anchorage Recording District, Seward Meridian, Alaska, Described in that certain written instrument recorded on the 24th day of April 1956, at Volume 130, Page 367, on file in the office of the District Recorder, Anchorage Recording District, Seward Meridian, Alaska, herein "Easement'') which pertains to the following described real property: The westerly Ten Feet (10') and the southeasterly Ten Feet (10') of Block One (1), Lot Eight (8), The Landings Subdivision, according to Plat Number 69-37, recorded on the 2nd day of April 1969, and the easterly Forty Feet (40') of the southwesterly Fifty Feet (50') according to the easement recorded at Volume 130, Page 367 on the 24fl, day of April 1956 on file in the office of the District Recorder, Anchorage Recording District, Seward Meridian, Alaska, Permittee acknowledges the validity of the Easement. Permittee warrants and represents that Permittee is the owner of the fee simple interest in the land subject to the Easement and the following described real property to which the Easement is adjacent: Lot Eight (8), Block One (1) of the Landings Subdivision, according to the plat filed under Plat Number 69-37, Records of the Anchorage Recording District, Third Judicial District, State of Alaska. (herein "Parcel") Encroachment Permit - Page 1 of 4 eRecorded Document Encroachment. Permittee plans to construct, the following improvements on or within the real property subject to said Easement: Septic system including a septic tank, 3 bedroom treatment pod, and Twenty Foot (20') x Thirty Foot (30') drainfield to encroach Twenty Feet (20') into the westerly side of said Forty Foot (40') easement, an existing approximately Ten Foot (10') x Fifteen Foot (15') deck and log crib (to be decommissioned per UPC) that encroach approximately Ten Feet (10') into the easterly side of said Forty Foot (40') easement, and approximately Five Foot (5') x Five Foot (5') and Five Foot (5') x Ten Foot (10') portions of an asphalt driveway that encroach approximately Five Feet (5') into the northeasterly side of said Forty Foot (40') easement. (herein "Encroachment"). 3. Permit. Chugach hereby authorizes Permittee to construct and continue the existence of the Encroachment in its proposed location subject to the covenants set forth in this permit. 4. Indemnification. Permittee shall indemnify and hold Chugach harmless from any claims for personal injury, property damage or other loss arising in any way from the continuation of the Encroachment. 5. No Expansion or Increase. Permittee shall not in any way expand or increase the extent to which the Encroachment occupies any of the real property encumbered by the Easement without the prior written consent of Chugach. Chugach has no obligation to provide such consent. 6. No lii mewl i:i ltesl Estate i c%L red. Permittee hereby acknowledges that the Encroachment and any additions thereto, even if in violation of this permit, has not and shall not in the future give rise to any interest or estate in the real property subject to the Easement or any other real property. Without in any way limiting the foregoing, Permittee acknowledges that the Encroachment is not adverse to any interest of Chugach and its continuation is entirely with the permission of Chugach for purposes of the common law doctrine of adverse possession. This permit creates no interest in the real property subject to the easement. 7. If the electric utility facilities located within the Easement are upgraded, added to, replaced or reconstructed, Permittee shall pay that portion of Chugach's total costs for such modification which is reasonably attributable to accommodating or preserving the Encroachment. If such payment is not made within thirty (30) days of written demand for same, Chugach may terminate this permit in accordance with paragraph 9, below. 8. Covenants RUnlii1%1 witli the Land. The obligations of the Permittee arising from this permit shall be covenants running with the land which shall burden the Parcel and the Permittee's interest in the land subject to the Easement and shall benefit the Easement. Encroachment Permit - Page 2 of 4 2 of 4 eRecorded Document 301-2022-041655-0 9. Termination. Chugach may terminate this permit after the giving of thirty (3 0) days written notice of such termination if: a. The Encroachment is enlarged, increased or extended within the real property affected by the Easement. b. The Encroachment is damaged by 'any means to an extent of more than thirty percent (30%) of its replacement cost at the time of destruction. C. Permittee fails to make the payment described in paragraph 7, above. 10. Term. This permit shall, if not sooner terminated by Chugach, expire forty (40) years from the date hereof. 11. Emire Nucernem. This written permit constitutes the entire agreement between the parties with respect to the subject matter hereof and supersedes all other prior or contemporaneous agreements, oral or written, between the parties. No modifications, amendments, deletions, additions or alterations of the permit shall be effective unless in writing and signed by all of the parties hereto. CHUGACH ELECTRIC ASSOCIATION, INC. q+V-th� Karen Keesecker, Manager Land Services Department Date:- 11 0 eRecorded Document PERMITTEE Arvin A. Miller Date: 1 I 4 -q lvlar or 1. Miller Date: 1, % 1 -.91,0 61 - Encroachment Permit - Page 3 of 4 3 of 4 301-2022-041655-0 STATE OF ALASKA ) ) ss: THIRD JUDICIAL DISTRICT) The foregoing instrument was acknowledged before me this K day of 2022, by Arvin A. Miller. NOTARY PUBLIC Lorraine Aldea Lehman STATE OF ALASKA My Commission Expires June 25, 2024 ry Pullic d for My commission expires: --T : a5; :;?()a STATE OF ALASKA ) ) ss: THIRD JUDICIAL DISTRICT) The foregoing instrument w" acknowledged before me this day of 2022, by Marjorie I. Miller. NOTARY PUBLIC Lorraine Aldea Lehman STATE OF ALASKA My Commission Expires June 25, 2024 STATE OF ALASKA ) ) ss: THIRD JUDICIAL DISTRICT) 4ot�aryyPublic t d for My commission expires:, d tk The foregoing instrument was acknowledged before :me this_%day of _ �y`��Z 2022, by Karen Keesecker, Manager, Land Services Department, of Chugach Electric Association, Inc., an Alaska corporation, on behalf of the corporation. NOTARY PUBLIC LorraineAldea Lehman STATE OF ALASKA MLCoremisslon Expires June 25,2D24 RETURN TO. Chugach Electric Association, Inc. P.O. Box 196300 Anchorage, Alaska 99519-6300 Attn: Land Services Department ar} Public in and for the State of Alaska My commission expires:1�.�_i�;_ Encroachment Permit - Page 4 of 4 4 of 4 eRecorded Document 301-2022-041655-0 O OFgt4%%4 C'9`49 r SHANE A. HOLT...' p LS -6914 0` Q�a o �Arofessiona� foa o O�� SHED CORNER ENCROACHES 59' THE INFORMATION HEREON IS FOR THE USE OF LENDING INSTITUTIONS SPECIFICALLY TO SHOW ANY CONFLICTS BETWEEN EXISTING STRUCTURES AND PLATTED LOT LINES AND/OR EASEMENTS, AND IS NOT TO BE USED FOR POSITIONING ADDITIONAL STRUCTURES, IMPROVEMENTS, OR FENCELINES. EASEMENTS OF RECORD OR OTHER RIGHTS OF WAY, OR ANY ENTITY NOT ON THE RECORD PLAT ARE NOT SHOWN HEREON, UNLESS NOTED. NOTE. FENCELINES THAT MAY APPEAR ON THIS DRAWING ARE NOT TO BE USED TO DETERMNE PROPERTY LINES OR POSITION ADDITIONAL IMPROVEMENTS. ANY PAVING SHOWN HEREON MAYBE APPROXIMATE DUE TO EXCESSIVE SNOW AND/OR ICE. • SEWER SYSTEM PIPE THESURVEYDATA AND MEASUREMENTS HEREONAREPREPARED FOR THE OWNER OFRECORD AS OF THEDA TE OF THIS SURVEY ANYUSE OF THIS DRAWING BY THIRD PARTIES IS PROHIBITED UNLESS WRITTEN PERM/SS/ON IS PROV/DED. AS-BUILTSURVEY I" =301 NO CORNERS SET THIS DATE I HEREBY CERTIFY THA TI HA VE PERFORMED A SURVEY OF THE FOLLOWING DESCRIBED PROPERTY LOT 8 BLOCK 1 THE LANDINGS SUB, ANCHORAGE RECORDING DISTRICT, ALASKA, AND THAT THE VISIBLE IMPROVEMENT S SITUATED THEREON ARE WITHIN THE PROPER TYLINESAND NO VISIBLEENCROACHMENTS EXIST OTHER THAN NOTED. DATED ATANCHORAGE,ALASKA THIS 87-H DAYOF AUGUST , 2022 HOL TLAND SURVEYING 9309 GROVFR DRIVE ANCHORAGEAK 99507 15580 225-22 223-8615 ~ %TER ANCHORAGI.: AREA BOROr'~H HEALTH DEPARTMENT 327 EAGLE ST. ANCHORAGE, ALASKA 99501 279-2511 N? 637 INSPECTION REPORT ON-SITE SEWAGE DISPOSAl. SYSTEM MAILING _ A D D RE S S ~j'..L.,¢.2 LEGAL DESCRIPTION SEPTIC TANK: NUMBER OF DISTANCE FROM WELl , )~'~ / __MATERIAL C~;/',L/~,C%~'~-.ZZ.--~-- COMPARTMENTS '/~'¢/~'~'~/ "/'~'~:'~/ Z'/~'/'¢'~/'~'~¢'~¢"¢'>~"'~¢' LIQUID LIQUID CAPACITY ;/,~/JZ~.~,,~,,' __GALLONS. INSIDE LENGTH INSIDE WIDTH. DEPTH. SEEPAGE SYSTEM: SEEPAGE PIT: NUMBER OF PITS / OUTSIDE DIAMETER. / OR WIDTH ,/'~¢¢./~//'~ ~, LENGIH ,¢';'~:~/ x , DEPTH LINING MATERIAL ,-~- ~' /'-( ~-'J~¢~","'~'~' ,,) DISTANCE FROM WELL NEAREST LOT LINE _/_~,/./1/..4~, TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) ~-.-.-.-~4:~ SQ. FT. TILE DRAIN FIELD: DISTANCE FROM WELL / ~.--~'~, FOt~NDATION_ NUMBER OF LINES / DISTANCE BETWEEN LINES ABSORPTI~AREA SQ. FT. LENGTH OF EACH LINE DEPTH: TOP OF TILE TO FINISH GRADE ~'NE~EST LOT LINE H WIDTH .DEPTH OF FILTER MATERIAL BENEATH TILE TOTAL LENGTH , OF LINES IN. 1OTAL EFEECTIVE IN. ABOVE TILE WELL: /~¢' '¢'¢~"¢~-~ '-.- / DISTANCE FROM / WATER T Y P E.~'~-/Z//~ -~--'~-~;~ DEPTH.-'(~/ ,BUILDING FOUNDATION.~__SAMPLE ,/V",~ NEAREST NEAREST ~' SEPTIC ~.~ / SEEPAGE LOT LINE //*/~ / ~2~' , SEWER LINE_//~' , TANK ~ ~J¢ , SYSTEM__ .///.~: ,CESSPOO[ .,.'¢/'~,.~SOURCE8 DISTANCES: DIAGRAM OF SYSTEM GREA~ER ANCHORAGE AREA BOR',.JUGH SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT PHO'E ? , OTHER NOTE= THIB PERMIT,,, IS NOT VALID WITHOUT?~OI~ ~TE~ FINAL INSPECTION: 24 HOUR NOTICE RE, QUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPEGTiON DY THE HEALTH DEPARTMENT AUTHORITY WILL BE SUBJEGT TO PROSECUTION. (,/z >'o J FOUNDATION TO SEPTIC TANK J~ / FOUNDATION TO SEEPAGE PIT ~2 O ~ , DRAIN FIELD SEPTIC TANK TO SEEPAGE Pit WALL SEPTIC TANK '~ ~ . SEEPAGE Pit ~ * -, DRAIN FIELD TO NEAREST LOT LINE, WATER MAIN TO SEPTIC TAN~ ~ /~ DRAIN FIELD / ~ SEPTIC TANK, ~ / / SEEPAge PIt ~ ., DRAIN FIELD SEEPAGE PIT /~/ ALSO CONSIDER AREA WELLS. SEEPAGE PIT /~/ CAST IRON INTO AND OUT OF SEPTIC 'rANI( AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTed WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. HEALTH AUTHORITY OR LICENSED DESIGNER I CERTIFY THAT ] AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAI~ CODE. DATE ~./~/ APPLICANT'S SIGNATURE