HomeMy WebLinkAboutTURNAGAIN INDUSTRIAL PARK Onsite Sewerage Disposal Systems December 4, 1975 DOWL Engineers 4040 "B" Street Anchgrage, AK 99503 Attention: Mr. Maurice Oswald Subject: Turnagain Industrial Subdivision Gentlemen: In response to your request we have formulated an opinion with regard to the site's ability to accept onsite sewerage disposal systems. The site has been previously developed as a commercial sand and gravel source. Similar developments to the west, east and south indicate the exposed soils to be general to the area. Exploration in the northwest indicates clean permeable soils exist to significant depths. The attached photographs and logs of stockpiles and cut faces indicates the undisturbed soils to be permeable, and to be predominately in the SM and SP groups with some layers of GP's, SM's and ML's. We expect the soils to have sufficient ML layers to be rated as SM upon remixing and use as borrow. We understand that %he waste piles of overburden which include SM's, ML's and organic matter are to be removed. We understand that the topography is to be substantially altered, with deep cuts and thin fills to be the general condition. DOWL Engineers December 4, 1975 Page 2 und water is encountered to the northwest and follo ~x~~l-rainage to the west. Based on these data including 13 locations throughout property we do not expect percolation to be a general problem to the subdivision. the We recommend that percolation, soil type, and water table be verified after the general grading plan is impl~nd as the structures are adjusted by consideration of the general area. Very truly yours, A LA S KA T E S T LAB ~. ~ ~R .~i~e e~ HRL:mm Attachments .4-1