Loading...
HomeMy WebLinkAboutUS SURVEY 3200 LT 23Onsite File US Survey 3200 Lot 23 #090-041-26 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343.7997 hllp://www. muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP201470 Work Type: Septic Upgrade Tax Code Number: 09004126000 Site Legal Address: US SURVEY 3200 LT 23 G:4454 Site Mailing Address: 199 INDIAN RD, Indian Owner: SPENCER JOHN S Design Engineer: ANDERSON CONSTRUCTION & ENGINEERING This permit is for the construction of: Effective Date: Expiration Date Lot Size in Sq Ft: Total Bedrooms: 11/17/2020 11/17/2021 126759 21 Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: 1. A portion of the proposed primary and alternate absorption fields is outside the 30 ft radius of the percolation test. An additional percolation test is required prior to construction of the absorption field. If results require a design change, construction shall stop pending review and approval of a change order. Please submit results 41, with the inspection report (or change order, if required). A 2. MOA GIS maps show slopes greater than 25% that appear to be within 50 ft of proposed drainfields. Slopes shall be verified by MOA at time of inspection. a Received By: Issued By: Date: ( I u? Zo Date: qi Q ii MUNICIPALITY O Development Services Department '`� Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION , Parcel I.D. 090-041-26'� JOHN SPENCER Property owner(s) Day phone Mailing address HC BOX 8801, INDIAN AK Site address SAME Legal description (Sub'd., Block & Lot) US SURVEY 3200 LT 23 Legal description (Township, Range & Section) Lot Size 126,759 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field F-1 Initial ❑ Single Family (SF) 0 (w/wo ADU) Septic Tank 0 Upgrade Q El (D) Holding Tank ElRenewal ElDuplex Multiple Dwellings ❑ Privy El (SF and/or D) Private Well ❑ j 4� Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: � 71 y V I d- i �) Date of Payment: 1 I 1 5 ZD '?_0 Receipt Number: 06 5 'Z -] Z Permit No. o S�, a O i y� o Waiver Fees: Date of Payment: Receipt Number: Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc Nov. 16, 2020 Municipalities of Anchorage Departments of Health and Human Services P.O. Box 196650 Anchorage, Alaska 99519-6650 Fax 249-7847 Re: Septic Permit Legal: US SURVEY 3200 LT 23 To Whom it may concern: This is a request for a septic permit on the above referenced lot. One test hole was excavated and found silty gravels & sands (GM/SM) for the entire depth with water at 14 feet after the 7 day monitoring period. A new 1250 gallon plastic tank will be installed and a gravity flow deep-trench system. The perc rate was 26 minutes. The lot slopes to the south at 4.5 to 1 with the slope getting steeper (3.5 to 1) on the west side. This new system will not impact any of the surrounding neighbors. Sincerely Michael N. Anderson, P.E. 4661 Natrona Anch, Ak 99516 Ph 727-8864 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201470, Rebecca Carroll, 11/17/20 SEPTIC FIELD SECTION DESIGN CRITERIA: 7.0' EFFECTIVE 4 BDRM X 150 = 600 GPD SOILS = 600/0.6 = 1000 SQ FT REQ'D 1000/2(7.0) = 71.4', USE 72' 2.0' WIDE 72' LONG (1) TRENCH 8' DEEP -16' (TH#1) -1' SM/GM OR 2.0'2.0' -8.0' -1.0 MOUND OVER FILTER FABRIC SEWER ROCK ‘ 3,3( GRADE 1"=200' PROPERTY LINE PROPOSED DRAINAGE FIELD EXISTING HOUSE 7.0'EXISTING WELL/SPRING 100' RADIUS SCALE: DJRDRAWN: DATE: US SURVEY 3200. LOT 23 Indian, Alaska JOHN SPENCER 10/8/2020 ALAS K A R AI L R O A D SEW A R D HIGH W A Y -INDIAN ROAD-EXISTING SEPTIC & INSULATION Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201470, Rebecca Carroll, 11/17/20 1"=50' PROPERTY LINE EXISTING HOUSE NEW 1250 GALLON PLASTIC TANK W/ 20" RISER W/ 5' MIN. BETWEEN TANK & FIELD EXISTING UNDOCUMENTED SYSTEM TO BE DECOMMISSIONED PER UPC DRIV E W A Y SLOPE, 3.5.0:1TYP.WELL/SPRING US SURVEY 3200 LOT 23 SCALE: DJRDRAWN: DATE: US SURVEY 3200. LOT 23 Indian, Alaska JOHN SPENCER 10/8/2020 US SURVEY 3200 LOT 22 US SURVEY 3200 LOT 24 CO DCO DCO TCO TCO CO MT CO TH#1 SLOPE, 4.5:1 TYP.NO SLOPES OR CUT BANKS WITH 50' OF SITE NEW TEST HOLE REQUIRED PRIOR TO EXCAVATIONSLOPE, 4.5:1 TYP.SLOPE, 4.5:1 TYP. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201470, Rebecca Carroll, 11/17/20 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201470, Rebecca Carroll, 11/17/20 S t W/ircv _ y/Gyw-4 Y 555726 W I AS -BUILT I LJodiFedA"Frame House with cause Wayaffac)iad Nloin>lenance Shao Gavernm�en�LoiP3 U. S.Surv�u-3ZOO Registered Land Surveyor PO. Box 111551 345 5339 Anchorage, Alaska. 99511 345 0927 4 i3 � / 8.,0, 1 14 4 54 1/ of / R M SIGNED I:IEPLY SIGNED . .. _._.R~lr't"~M. 4S 472 SEND PARTS 1 AND 3 INTACT - ................. PART 3 WILL BE RETURNED WITH REPLY. DATE / carbonless POLY PAK (50 SETS) 4P472 Scale Drawn by F. 8. Grid Sheer /'~/oo' ~.~.~. 2~,~ ~.,,z~4 / of/ X 0 •A, > r4 h m�:oe•.mom ' c1 James J. Rodgers a N.. 43d7S F9F0n'eyo•..eoN•a RQFFSSIONA4 ���' A 5-8UIL T Modifrre d fJ "Frame House wifh C041,56 -way nfachc • Moinfenarice S/7010 Goverrr,-neni Lo/ 23 U.S. Survc 320o JAMES B. RODGERS Registered Land Surveyor P. O. Box 111551 345 5339 Anchorage, Alaska.995ii 345 0927_ Date Scale I Drown by F. B. Grid I Sheet 4-i3< /"=ioo' ✓. B.,P �.�y '� 1s4 I of / unicipality of Anchorage MEMORANDUM DATE: TO: FROM: SUBJECT: April 29, 1988 Accounting & Budget ESD, On-site Services/Water Quality Request for Refund - Account # 2570-9426 Please make arrangements for the following refund of the permit application. After review, by staff, this well permit~ can not be issued without proper wastewater disposal system serving the property. USS # 3200 Lot 23 John Spencer HC 52 Box 8801 Indian, Alaska 99540 Receipt #1102/0S-20283 Amount $50.00 Laura j. Ward On-site Services/Water Quality attachments Municipality of Anchorage ~ OS-- DEPARTMENT OF HEALTH AND HUMAN SERVICES Environmental Services Division Telephone:.343-4744 ON-SITE SERVICES FEE DOCUMENTATION Name of Payer: (kJame on Check) Mailing Addre,ss: (Off o~r~heck.) ,kk c Legal Description(s): "~ ~ Permit Number: Receipt #: Check #: //0 O- Type of Payment: (Indicate Amount Paid) ?-alth Authority: 3ewer & Well Permit: Well Permit: Sewer Permit: Copy Request: 72-034 (Rev. 10/87) Excavator Permit: Engineer Permit: Pumper Permit: Well Driller Permit: Tank Manufacturer: (Waste Treatment) DISTRIBUTION: WAIVERS: Lot Line: Well to Tank: Well to Field Tank to Surface Water CANARY PROGRAM FILE · WHITE--MASTER FILE