Loading...
HomeMy WebLinkAboutUPLANDS Plat# 94-55 S-9403 ._ J , MUNICIPALITY OF ANCHORAGE ] OFFICE USE COMMUNITY PLANNING AND DEVELOPMENT P.O. Box 196650 REC'D BY: Anchorage, Alaska 90510-6650 PRELIMINARY PLAT APPLICATION Please fill in the information requested below. Print one letter or number per block. 1. Vacation Code 2. Tax Identification No, 3. Street Address 4. NEW abbreviated legal description (T12N R2W SEC 2 LOT 45 OR SHORT SUB BLK 3 LOTS 34). MJ lalnldlsl I Islulbldlilvlilslilol.I I I I I I I I I I I I IIIIIIIIIIIIIIIIIIIIIlll 5. EXISTING abbreviated legal description (T12N R2W SEC 2 LOT 45 OR SHORT SUB BLK 3 LOTS 34) full legal on back page. 6. Petitioner's Name (Last - First) Smith. Phyllis M 7. Petitioner's Representative Address P.O. Box 1605 City ~gl~ Rivsr State Alaska Phone# Zip 99577 Address 11940 Business Blvd. Suits 205 City Eaqle River State Alaska Phone #!694-4499 Zip 99577 8. Petition Area Acreage 9. Proposed Number Lots 10. Existing 11, Grid Number 12. Zone Number Lots 13. Fee $ ~-~-~,o~) 14. Community Council Eagle River Valley Date: I hereby certify that (t am) (I have been authorized to act for) the owner of the properly described above and that I desire to subdivide it in conformance with Chapter 21 of the Anchorage Municipal Code of Ordinances. I understand that payment of the basic subdivision fee is nonrefundable and is to cover the costs associated with processing this application, that it does not assure approval of the subdivision. I also understand that additional fees may be assessed if the Municipality's costs to process this application exceed the basic fee. I further understand that assigned hearing dates are tentative and may have to be postponed by Planning Staff. Platting Board, Planning Commission, or the Assembly due to administrative reasons. ~-~b~/~ Signature '~-~ ~' ~ *Agents must pro'~tde written proof of authorization. · Please ~heck or fill in the following: 1. Comprehensive Plan-- Lend Use Classification × Residential Commercial Parks/Open Space Transportation Related Marginal Land Commercial/Industrial Public Lands/Institutions X Alpine/Slope Affected Industrial Special Study 2. Comprehensive Plan-- Land Use Intensity Special Study Dwelling Units per Acre X Alpine/Slope Affected 3-9 Environmental Factors {if any): a, Wetland 1. Developable 2. Conservation 3. Preservation b. Avalanche c, Floodplain d, Seismic Zone (Harding/Lawson) D. Please indicate below if any of these events have occurred in the last five years on the properly, Rezoning Subdivision Conditional Use Zoning Variance Enforcement Action For Building/Land Use Permit For Army Corp of Engineers Permit Case Number Case Number Case Number Case Number E. Legaldescription for advertising. ND -~ of ~'~ ~, and W ½ of NN ~, and W ½ of SN ~, all ±n 'che SE ~ of Sec 8, T14N, R1W, S.M. F. Checklist TO ~3(~Copies of Plat P'~ Reduced Copy of Plat (8 1/2 x 11) Y Drainage Plan ~/ Certificate to Plat ~ .Topo Map 3 Copies /// Aerial Photo ~ Soils Repod 4 Copies Housing Stock Map ~"///~ Pedestrian Walkways ~'/ Zoning Map ~ [~ Landscaping Requirements Waiver '/ Water: / Private Wells Community Well Public Utility ~ Sewer: ~/'Private Septic Community Sys. Public Utility 20-003 Back (Rev. 992} · LAND SURVEYS TRAINING 4(c) McCLINTOCK LAND ASSOCIATES, INC. 11940 BUSINESS BLVD., SUITE 205, EAGLE RIVER, ALASKA 99577 April 19, 1993 Municipality of Anchorage Economic Development and Planning P.O. Box 196650 Anchorage, Alaska 99519-6650 Re: Proposed Uplands subdivision - DI~%IN~EN~RRATI~E Ladies & Gentlemen: We are submitting a preliminary plat for the above referenced subdivision. A total of two lots are being created from 1 original large parcel. No ~oad construction is anticipated other than a driveway from the end of Stewart Drive into Lot 1. The development of this subdivision will not impact the existing natural drainage. We request that the Platting Board approve this subdivision without any stipulations concerning drainage. Sincere ly, Bill McClintock Registered Land Surveyor Phone: (907J 69~ ~/,99 ~j~ Fax: (907J 694-3297 ~ AK Toll Free: 1-800-478-4499 4- 6 7 8 9 10 11 12 13 15 16- 17- 18- 19- 20 COMMENTS Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST ~--~ )~l'~'T°wnship' Range, Sect on'''''T'T.,/\~ , ~1 ~ ~--~, ~ ~ /4~ sLoPE S,TE~PLAN 3 2 4 199 WASGROUNDWATER ENCOUNTERED? IF YES, AT WHAT ~ross Net Depth to Net Reading Oate Time Time Water Orop ~ ~-" ~ Io~"', '~"/~' I~,' ~ ~:~ - ~ , ~/~" . PERCOLATION RATE . . TEST RUN BETWEEN -- (minutes/inch) PERC HOLE DIAMETER FTANO ~ FT PERFORMED BY: S & S ENGINEERING \-"-' ~' 17034 Eagle River Loop Read No, "M~ ACCORDANCE WITH ~[~.T~,iT~i~,~NI(~:~GUIDELINES IN EFFECT ON THIS DATE. 72-008 (Rev. 4/85) CERTIFY THAT THIS TEaT WAS PERFORMED IN DATE; ~ (~-- I'"~--~::~"~''"~ PERFORMED FOR:~'~~ ~¢ Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST LEGAL DESCRIPTION: 1 2 3 4 6 7 8 9 10 11 12 13 14 15 16 17- 18 19 2O Township, Range, Section:"~f-I~ ,,'~\ SITE PLAN SLOPE 'EWN~cSoGuRNOTL~%%D~?ATER ~'~f~ 's/I I I I I I I I I-~ IF YES, AT WHAT' O DEPTH? .- Depth lo Water Alter Monitoring? ~)~'~ Date' \ Reading Date Time Net Depth to Time Water ~ ~(,~' Net Drop PERCOLATION RATE TEST RUN BETWEEN (minutes/inch) PERC HOLE DIAMETER -- FT AND ~' FT COMMENTS S & S ENGINEERING ~ PERFORMED BY: 17034 Eagle River Loop Road No. 204 Is DATE ACCORDANCE WIT~e~:~'i¥/3~,'~[~h~l~L GUIDELINES IN EFFECT ON TH · 72-008 {Rev. 4/85) CERTIFY THAT THIS TEST WAS pERFORMED IN DATE: I, · ' DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephon.e~-~-172L~ 3 ~ ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL I~F~T]ON REPORT . o 5 ~.~w LEGAL / / ~ Welll/ / [~ I Absorption,area ~ Dwel]in9 ~ I ~ m I Liq. capacitv in galJons Inside length J Width Liquid depth ...~ ~ DISTANCE TO: Well Dwellin~ / ~ PERMITNO. O ~ < Manufacturer Material Liquid capaciw in gallons ~ DISTANOETO: /~"~ Foundation d¢ '~ Neares~ne'~ ~'~_ =. N°' °f lines / Length °f eac~lin~ = T°tal leng'h °f I~e~ -- T~n %i d * inches -- ¢ t¢ M terial bonea ,il, Total ef fectiv, a~o~tion area L~ngth Width ¢Oepth / ; PERMIT NO. ~ ~ Type of crib Crib ~ameter C ep Total effective absorption area Class ~ '" ' Depth Driller Distance to lot line PERMIT NO. ~ DISTANCE TO: Sewer line Septic tank I Absorption area(si PIPE MATERIALS 72-01 3/78) _,~rlI T NO, ;~;:..~ T"~-" ~"' 1--~I1"-4CI--¢' "IF~-.'FIF~E ' HEBLTH Ri"-.ID ENb'IRIDNMENTFIL , ,STECTION .:,,~5 '"L" STREET, RNCHORRGE, 264-472(t CH"4--S I TE SEI-4EF-.' LIP~SF-:RDE F'Et~-."r'l I T ( 888515 ) HTI _N.~ ,'~.IW SEC 8 :SE4' NE4-'NW4 "SW'21-;'~12 :SW4 1 ,PE ElF SOIL RE, SORF'TION ~-r'-,TEi',I IS: TRENCH 694-9444 =,I...!UFIR E FEFT ,,IMIJM NI_If'IBEF~: FIF BEDROOMS '-50IL RFITINCi (:St:-'.! FT,..'BR)= 158 {E REQUIRE[:, SIZE OF THE SOIL RBSORF'TION _,T_~TEi'I IS: · EF'TH= '--%~- LEI"--~G TH = 45 G F-: R ',,-' E b '[:,EP TH= 5 THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRRtNFIELD. THE DEPTH OF 8 TRENCH OR PIT IS THE DISTRNCE BETWEEN THE SURFRCE OF THE GROUND RND THE BOTTOM OF THE EXCRVRTION (IN FEET). THERE tS NO SET WIDTH FOR TRENCHES. THE GRRVEL DEPTH I5 THE MINIMUM DEPTH OF GRRVEL BETWEEN THE OUTFRLL PIPE RND THE BOTTOM OF THE EXCRVRTION <IN FEET). El::.!l_I I F-:E[:, SEPT I ~$ T~-91'-.II-=:.' S I ZE= ± ~-_---l~-Z-IO ISRLL~DI"-4S [Ri"IIT FIF'PLICRNT HFiS THE RE_,FON-,IE, ILITT TO INFORM THIS DEF'RRTMENT [,IIRING THE ,I.:,THLLHTIJN IHSPEI_-.'TIIZIN~ OF FiN'¢ WELLS FIDJFtCENT TO THIS FF_FEI~T'r FIND THE .IMBER OF RESIDENCES THFIT THE HELL !4ILL SERVE T 1.--~ ~z~ ':: 2 ::' :ICKFILL!NG OF Ri'.,I'¢ ~'r_TEM ~4ITHCILtT FINRL INx, PEL. TIuN RND RF"PROVFIL B'¢ THIS :'PFIRTMENT WILL BE SUBJECT TO FRu_,EuUTIUr.I. :NIM, UM DI_-,TFINbE BETWEEN FI HELL FIND FIN'T' ON-SITE _,EI..IHuE E:I_,FEI~HL _,-L, TEI'I I~ )E~ FEET FOR R PRIVFITE .{4ELL OR 2L50 TO 200 FEET FROM FI F'UBLIC: WELL [:,EPENDING :'ON THE T',?F'E OF PUBLIC ~.,.~ELL. ;NIMOM DISTRNL-:E FRFiM FI PRIVRTE !.4ELL TO FI FEI HTE _EHER LINE t_- .... FEET FIND ) R CFd'.IMLII'.,IIT'9 SEWER LINE IS 75 FEET: 'HER F'E;,_IF'EHENTS i"lR'¢ FIPPL¥. _,FEuIFIL. HTtON_, RND CONSTRUCTION DtM~aF. Ri'I_, RRE ,'RILRBLE TO INSURE PROF'ER INSTFILLFITION. PEFir-~ I T E.':-::F' I RES C, EC:Ei'"IE:EF-: .2'<--1 . _ 19:----:E~ -. .... THRT _.ERTIF? Fli"l FFII"IlLIFIR WITH THE REQUIREMENTS FOR ON-SITE SE.t4ERS FINE'., HELLS RS SET )RTH B'¢ THE i"IUNICIPRLIT'T' OF FINCHORRGE. WILL ti'..ISTRLL THE SYSTEM IN FICCORDFINCE .t4ITH THE CODES. ONDERSTFIND THFIT THE L-IN-SITE SE.t4ER '_-S'T'STEi"I i'dR'-? REQUIRE ENLARGEMENT IF THE ~SIE:,ENC:E I=,'- "REMODELED TO INC:LLIDE MORE THRN 3 E:EDROOMS [] $01L3 LOG MUNICIPALITY OF ANCHORAGE "' ' ':' DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION "~ PERCOLATION r.~-.: TEST ' =~ ~' ' :; 825 L. Street, Anchorage, Alaska 99501 2644720 / / / / SLOPE N SITE PLAN . 3 4 6 7 / / / jl 10 11 12 13 15- 16- 17- 18- 19- 20- COMMENTS PERFORMED BY: 72-008 (6/79) ENCOUNTERED? IF YES, AT WHAT DEPTH? Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE (minutes/inch) TESTRUN BETWEEN ~' FTANDt~ FT ¢ J / NORTH