Loading...
HomeMy WebLinkAboutUPPER EAGLE RIVER ESTATES BLK 1 LT 105 - ol GR ' ANCHORAGE AREA BO ,JGH Department of Environmental (~uality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM SEPTIC TANK: DISTANCE FROM WELL ~[0' INSIDE LENGTH MANUFACTURER ~(~/t~ &/g_~/ MATERIAL INSIDE WIDTH LIQUID DEPTH NUMBER OF COMPARTMENTS LIQUID CAPACITY /~00 GALLONS. SEEPAGE PIT: NUMBER OF PITS / , DIAMETER __ OR WIDTH /~/ LENGTH /''~'' DEPTH LINING MATERIAL ~,.'t/~.~"f~ CRIB SIZE: DIAMETER__DEPTH DISTANCE FROM: WELL /~/ , ,~ I TOTAL EFFECTIVE BUILDING FOUNDATION ~// NEAREST LOT LINE ~ ABSORPTION AREA (WALL AREA) ~ SQ. FT. ADDITIONAL ABSORPTION WELL: TYPe '?')1~/1"£~ CONSTRUCTION DePtH DISTANCE FROM: BUILDING NEAREST NEAREST SEPTIC SEEPAGE FOUNDATION LOT LINE SEWER LINE TANK SYSTEM CESSPOOL OTHER SOURCES APPROVED DISAPPROVED REMARKS DISTANCES: INSTALLED BY: PIPE MATERIAL: LOT SLOPe, WQ-~' REMARXS: /Z~ir~u~ $OlL ~OOD Form No. EQ-031 DIAGRAM OF SYSTEM GReATEr ANCHORAGE Area BorOUGh DEPARTMENT OF ENVIRONMENTAL QUALITY SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT (7 ,- .., , ,// . ,- //~?[ INSTALLATION OF: SEPTIC TANK TYPE AND SIZE OF FACILITY TO BE SERVED FINANCED THROUgh 5~/ ¢ PHONE SEEPAGE PIT ~ DRAIN FIELD , OTHER , _~.,~'/'~,~/ ROTE:, T'lS PERMit IS INOT VALID WITHOUT SOIl. TEST FINAL INSPECTION: 24 HOUR NOT~CE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY W~LL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE ~/~)~-~ ~t~(I, TYPE ~/~0~:-~. ~,~ SEEPAGE AREA SIZE TYPE ~1' U MINIMUM DISTANCES, REQUIREMENTS FOUNDATION TO SEPTIC TANK ~ [ FOUNDAtiOn TO SEEPage PIT ~ f) ~ , Drain FIEld SEPTIC TANK TO SEEPAge Pit WALL / ,Ej [ SEPTIC TANK , SEEPAge PIT /~ ~( DRAIN FIELD TO NEAREST LOT LINE. WELL TO SEPTIC TANK //~(~O , SEEPAGE PIT DRAIN FIELD [ (~(9~ t , ALSO CONSIDER AREA WELLS. SEPTIC TANK, ~(~0C /~0[ ~ SEEPAge PIT DRAIN FIELD . CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION S FEET INTO UNDISTURBED SOIL. INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT F]TTED WITH AIRTight REMOVABLE CAPS. [ CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. GREATER ANCHORAGE AREA BOROUGH DEPARTMENT OF ENVIRONMENTAL 333O ANCHORAGE, Performed For ~:5~ Legal Description: ~ot ? Block This Form Reports Soils Log / m Soil Test Must Be Logged To 4' Below Depth Feet Soil Characteristics 2-- 3-- 6-- 10-- 11-- 12-- 14-- Was Ground Water Encountered? If Yes, At What Depth? QUALITY "C" Street ALASKA 99503 Case # Dated Per fo rme d~/~__~_~ S ubdi vi s i o n_/~ ~ ~//~ ~, Percolation Test Proposed Seepage System - ! I I Reading Date Gross Time Net Time Depth to H20 Net Drop I Percolation Rate Minute Proposed Installation: Seepage Pit Depth of Inlet ~ Depth to COMMENTS: / Drain Field Bottom of Pit OP Trench' Test Performed BY , ~c . _ Date Certified BY: Date: G^:ATER ANCHORAGE AREA BOROUGh?' DEPARTMENT OF ENVIRONMENTAL QUALITY 3500 TUDOR ROAD DATE RECEIVED: INSPECT: TIME: APPROVAL REQUEST FOR APPROVAL OF INDIVIDUAL SEWER AND WATER FACILITIES FOR ADDRESS: P.ON~:~~=:~9'/?/ PROPERTY OWNER: REQUESTED ~BY: ~,,_~ PHONE: LEGAL DESCRIPTIONi TYPE FACILITY TO BE NUMBER OF BEDROOMS: WELL DATA: A. TYPE B. DEPTH C. D. E. SIZE CONSTRUCTION BACTERIAL ANALYSIS 6. SEWAGE DISPOSAL SYSTEM: SEPTIC TANK (IF HOMEMADE, SHOW DIAGRAM ON ~. AGE l~b 7' / BACK) APPROVAL REQUES~- FOR SEWER & WATER FACILITILS PAGE TWO B. SEEPAGE PIT l, SIZE 2. LINING C. DISPOSAL FIELD 1. NUMBER OF LINES 2. TOTAL LENGTH REQUIRED ~EASUREMENTS B. C D E F G H WELL TO SEPTIC TANK WELL TO SEEPAGE PIT WELL TO SEWER LINE WELL TO PROPERTY LINE WELL TO OTHER POSSIBLE FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT SEEPAGE PIT TO PROPERTY LINE 8. COMMENTS: CONTAMINATION APPROVED: I DISAPPROVED: APPROVAL VALID ~0~ ONE YEAR FROM DATE SIGNED. GREATER ANCHORAGE AREA BOROUGH DEPARTMENT OF ENVIRONMENTAL QUALITY