On-Site Wastewater Disposal System Permit
Permit Number: OSP181209 Effective Date: 7/31/2018
Work Type: Septic Upgrade Expiration Date: 7/31/2019
Tax Code Number: 05078107000
Site Legal Address: UPPER EAGLE RIVER ESTATES BLK 1 LT 5A G:0056
Site Mailing Address: 20321 RAVEN DR, APT B, Eagle River
Owner: HANSON JAMES R Lot Size in Sq Ft: 46207
Design Engineer: ARC TERRA CONSULTING INC Total Bedrooms: 4
This permit is for the construction of:
2 Disposal Field 0 Septic Tank 0 Holding Tank 0 Privy 0 Private Well 0 Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
•
Received By: Date: 7 3/
Issued By: ec.VCo'eti Date: 7®18
Municipality of Anchorage aF ,
, ,�
P.O. Box 196650 0 4700 Elmore Road
Anchorage, Alaska 99519-6650 • (907) 343-7904 ® Fax (907) 343-7997
http://www.muni.orglOnsite
Development Services Department
On-Site Water and Wastewater Section
**** VARIANCE/WAIVER REVIEW xxxx
Waiver#: OSV181050 COSA#: Permit#: OSP181209
PID#: 050-781-07
Legal Description: Upper Eagle River Estates Block 1 Lot 5A
Engineer: ArcTerra
Applicant: James R. Hanson
Your request for a waiver of the required 10 feet horizontal separation from the absorption field
to the property line has been approved. The approved separation distance is 2.0 feet.
This waiver approval applies to the proposed absorption field only. Any future upgrade to the
on-site wastewater disposal system will require all separation distances be met or another
approval from this department.
Waiver is Granted: X Waiver is not Granted:
Date: 7/31/16
16 Approved by:
Name of Reviewer
•
**** VARIANCE/WAIVER REVIEW ****
MUNICIPALITY OF ANCHORAG :1 JUL 18 zo18
. a. ti
4 ° ;:� 1 h
Community Development Department Phone: 90 --43-,`'ti" 9
Development Services Division Fax: 907-343- --
On-Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 050-781-07
JAMES R. HANSON 907-862-0566
Property owner(s) Day phone
Mailing address
8973 W PARKVIEW TERRACE LOOP, EAGLE RIVER, AK 99577
Site address 20321 RAVEN DRIVE, EAGLE RIVER, AK 99577
Legal description (Sub'd., Block & Lot) LAPP ER EA Ca L E RIVER ESY TES ,B LK 1 LT Si)
Legal description (Township, Range & Section)
Lot Size 46,207 Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
(Z all that apply)
Absorption Field Pi Initial ❑
Single Family (SF) El
(w/wo ADU)
Septic Tank P1 Upgrade Duplex (D) ❑
Holding Tank ❑ Renewal ❑
Multiple Dwellings ❑
Privy ❑ (SF and/or D)
Private Well ❑
Water Storage ❑
THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR:
772-&-A/C'ff 'TD /Wc)/ 'TV G/4" Distance: 2
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signatu - •/• •perty owner or authorized agent)
P: mit/Rush Fees: 5(o' Waiver Fees: 02//(5 //
Date of Payment: W ISY ?LS Date of Payment: 21t7
Receipt Number: 01570613 Receipt Number: 615706D
Permit No. Q3 P 1'I«0 ` Waiver No. (5V I1.1660
Permit App_9-1-12.doc
,FtcTERR,
ARC FRRA
CONSULTING, INC
o,T` r,,,�.� � 212 E.51°Ave,Anchorage,AK.99503
e Office(907)868-3791,Fax(907)868-3793
July 17, 208
Municipality of Anchorage
Development Services Department
On-Site Water &Wastewater Program
P.O. Box 196650
Anchorage, AK 99519-6650
Subject: Upgrade Sewer Permit& Lot-Line Waiver
Upper Eagle River Estates Bl, L5A
It has been determined that the absorption field of the subject property is
saturated. Subsequently, the owner has requested we proceed forward to obtain
a septic permit to upgrade the septic system.
The general slope of this lot is flat over the septic area. On June 26, 2018 a
testhole was performed to investigate soils and groundwater. The results of this
test are attached for your review. The proposed upgrade will serve the existing 4-
bedroom single-family residence. We propose to install two pressurized 50'
trenches. Due to lot layout and an unknown septic standpipe in the SW corner,
well radii, etc... we request a waiver to lot line of 2' from the proposed trench.
Groundwater was not encountered at excavation or at monitoring.
The property and adjacent lots are served by private water. There is no surface
water within 100' of the proposed system and there are no known curtain drains
within 50'. We do not expect there to be any adverse effect on adjacent lots by the
development of this system. If you have any questions, please contact me at 868-
3791 / FAX 868-3793.
Respectfully submitted,
ArcTerra Consulting, Inc.
Kenneth . !-_ , P.E.
Attachments: On-Site Sewer Application
Wastewater Absorption System Details/Site Plan
Soils Log/Percolation Test
20441 PTARMIGAN BLVD • EAGLE RIVER,AK 99577-8736 • PH(907)868-3791 • FAX(907)868-3793
WELL & WASTEWATER DISP❑SAL SYSTEM DETAILS/SITE PLAN
UPPER EAGLE RIVER ESTATES LOT 5 BLK 1
APPROX. WELL LOGO
•,;Z:, APPROX. WELL LOC.o
/Atilt&STAMM LOT 5B
• 11!d.'
\II'
FG. S 89'50'26' V 300.21'/ n sir
t• ' •e'
1
Lot 5A '
il.,
..
,• Block 1AshitsFIAT r�arF " "
°Oros nni
m _. W
LOT 6A $ ' I i`Pir'rKive"`�i\��
mm
_ FIAT _ g
.u n..x uc� ..Q-.
Tv MT•A MTR�, y
' Ct 4,7 M\O ��� fu
1 I now-in.„ MT PA 1o1 .. I�
b ,,,T 7!do-, $ I `-31 ;
I f , Y
"� '•47••' V 280.24' TILINT I
ar
RAVEN DRI
LOT 4 LOT 4A
cn 3 APPROX. WELL LOC.o
"0.
o
FLAG PROPERTY LINES
g, WELL RADII & EASEMENTS
PRIOR TO CONSTRUCTION Scale; 1'= 100'
135
DESIGN DETAILS PAGE 1 OF 2
CE 4 BDRM X 150 GPD = 600 GPD
L. 600 GPD/.6 GPD PER SQ. FT. = 1,000 SQ. FT
re w (1000 / 5 x 0.5 RF (4' GRAVEL) = 100 FT. TRENCH
USE 2 TRENCHES - 50' (L) X 5' (W) X 4' (ED)
a Total depth of system is 6' from original grade.
D Total depth of gravel below distribution pipe Is 4' ,
NO PUBLIC WELLS WITHIN 200' OF
PROPOSED SYSTEM. NOTES:
NO PRIVATE WELLS WITHIN 200' OF
Taj PROPOSED SYSTEM EXCEPT AS NOTED. 1. INSTALL 1500 GAL STEP & INSULATE TANK IF <4' COVER,
NO SEPTICSYSTEMS WITHIN 200' OF
2. INSULATE TRENCHES WITH 2' HD BURIAL FOAM IF < 3' OF FILL,
w PROPOSEDDWELL EXCEPTPTAAS NOTTED..
MIN. 2' FILL WITH INSULATION, >3' COVER NO INSUL REQ.
3. CONTRACTOR WILL ENSURE MINIMUM 2% SLOPE INTO SEPTIC TANK.
4. CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT
WELLS, SEPTICS EASEMENTS, PROPERTY LINES, ETC...
w —�\�
j<S OF �\ 1 PREPARED FOR: lE j?D
N �r��' ' 1 JAMES R. HANSON oti ''''‘ C `Cq ��
1 `r # 20321 RAVEN DRIVE ��
E r* . A %
WASTEWATER DISPOSAL SYSTEM DETAILS
UPPER EAGLE RIVER ESTATES LOT gA BLK 1
IRON PIPE S 89°50'26" W 300.21'
• •
In x I
('7 .-
ET
Lot 5A '
50' ° LINE PER
PLAT P-532
'-' - 0' UTILITY 40' GARA
ii EASEMENT EXISTING FIELD Block 1 6.= PLAT 78-159
t-11.11.11/.
+.1;--�
• •- -• ° CO 4a
CD
',el
x I /
0 / ---- C❑ 1
DECOMMISSION EXISTING S.T. i ,' 17.5'
23.0'
p x & LIFT STATI❑N PER CODE / 2.0'0, 28.0'
O I & INSTALL NEW 1500-GAL
x STEP TANK - ADD DIVERTER °01' r r STXR4 li.o'D 2-STORY FRAME
Z TO PROPOED & EXISTING FIELDS HOUSE 32.0
CO CO I I 79,0'
x •• 0 I+ 1 14 .5' 8.0' 24.0' 22.0'
FLAT MI _ _ 4,0
,E76< ADD INSUL, 111111 12D xCK24
'
Q� OVER DRIVE FLAT 1 S6' X135' 24.0' 111111 62
x 1.25 — PAVED DRIV STAIRS)
2 PVC ` 5' X 4'
Q
x Li o J
° 40.3'
TH18-1 MTs FLAT MTs 6' HIGH WOOD FENCE
xIS 2' +/- INSIDE OF
3 FLAT CI 1 PROPERTY LINE
N p---x , x x x x 2xFRN PL x x x x x x x x I x x +
F N PIPE 89°47' W 280,24'
30'
1
RAVEN DRI
m
U
W
a
D PRESSURIZED DISTRIBUTION SYSTEM HOLE SPACING DESIGN
1. RESIDUAL HEAD = 5'
2. HOLE SIZE = 3/16' = 1.00 GAL. PER HOLE @ 30 PSI
Eo- 3, 30 GALS (PUMP DELIVERY)/1,00 GALS./HOLE = 30 HOLES
W 4. 100 LF LATERAL/30 HOLES = 3.3' SPACING PER HOLE
`; 5, ALL HOLES SHALL HAVE CAPS INSTALLED PER MANUFACTURES SPECS,
Scale: 11= 40'
W .10:46`41"11101kPAGE 2 OF 2
<N OF r
`��\ PREPARED FOR: CTE
co
E �� 1 JAMES R. HANSON ti �R R�� �'
20321 RAVEN DRIVE
EAGLE RIVER, AK 99577 ,4'4° /,I�ek\� ''
N / * .4 : TH /�. �. ,Af / 907- 862-0566 , Ij II \
1 'M. D / 2f / FIELD BOOKS COMPUTED: ; IngI�Ian
Z , V1 Awa / BOUNDARY:BOUNDARY DRAM: BMW �,12CL' r��`1'
CE 711
�x Si ��`+ti* sTAX 4G: STAKING CHECKED: KMDco
t iii .`.ti,p�
cl `y' ' AS8UILT: DATE: '�•'`r�•-\'' �i
\ Py APB 07/17/2018 ‘.1°
9 ,,,' #
ESS O�� DWG. FILE: GRID: SW0056 c(F 0 \��e°�,
*4-4.NS 3 L
`\� ACAD FILE: FILE ,ae No.:- 8160 R, K 99577-°
RCTERR ARCTERRA �, ) OF AZ4 1
AY
� <
" CONSULTING, INC / Q' 4
i212 E. 51St Ave,Anchorage,AK.99503 / • '9
i • a Office(907)868-3791, Fax(907)868-3793 / ,k, 4 TH *
ovar
''<to 04,sul. ‘Nr•cfPi # "9 KENNET-F.1 ,`. tif .A. ,
SOILS PERCOLATION TEST I s
lik P •Ess •.4
Performed for: TAMES R. HANSON Date Performed: 6/26/18 \116..`""lb
Project: Upper Eagle River Est.B1,L5A TEST HOLE# TH 18-1
Depth
(Feet) SEE ATTACHED SITE PLAN
7,,v:.,.: FOR HOLE LOCATION
1- :,,, `, Org/OL
Was Ground water encountered? NO What depth? NA
2
Depth to water after monitoring? NA Date? 7/3/18
3- '0
4- .
' GM/SM Reading Date Gross Net ' Depth of Net
5- 'a? • -: Time Time Water Drop
6- . .,� , 1 7/3/18 1:00 - 6" -
I I
7-5' q 2 1:30 30 min 4 11/16" 1 5/16"
83 * 1:31 - 6" -
4 2:01 30 min 4 12/16" 1 4/16"
10- 5 * 2:02 - 6" -
1 1 • ,;. 6 2:32 30 min 4 12/16" 1 4/16"
12- ' 7
~
13- ' ' BOH 8
14- 9
15- 10
16- HOLE PRESOAKED 11
PRIOR TO TEST
17- 12
18- * Water Added
19- Percolation Rate 24 (min/in)Perc Hole Diameter 6"
20- Test Run Between 3 feet and 4 feet
I, Kenneth M. Duffus, certify that this test was performed in accordance with all State
and Municipal guidelines in effect on this date.
IRON PIPE S 89°50'26' W 300.21' CS---FD s/8• �--\
0 �\REBAR \
4ti)l- FD
Lot 5A 'TACK i IME F'i.G': I I I1.S'
l!7 Block 1 s .w 'i
;IT 4 GARAGE I I 11.8'
Ch O
® © I IM
In ,o .,
w
z
W
r vs• 230 47.3'-----.--
/ J
eo Zen4Z
r
i ; STAIRS:li!1!i l4 2-STORY FRAME CO
o , 1 ea HOUSE • o 3
Cr) ® 1 44• '4 eao• i O
00 DECK it 4 O \
1 1 STAIRS L,u fiu '
O x 33 2,0 e �, •
t 1
O • ', STAIRS 4 1 /fFDS/8
'
Z
6' HIGH VOOD FENCE 1 403 • --WOOD FENCE
/
IS 2' +1- INSIDE OF , , I
I
PROPERTY LINE i i V R= 20.00'
FD 3/4' ° • IS 89°47'00' W 280.24' AFD s////S/8• L- 31.39' LEGEND
IRON PIPE
�, REBAR
&SEPTIC PIPES ,
RAVEN DRIVE 0 WELL
•
I hereby certify that I have surveyed the following described r P �� S' wt.
ro Lot 5A, Block 1 Upper Eagle River Estates Subd., ''S;1'.
property: pPe b :' •9�
Plat No.78-159,Anchorage Recording District,and that no w4:' 49TH ';
encroachments exist except as indicated hereon. This As-built
will only show the easements that appear on the recorded •
.......
subdivisionplat No. 78-159,Anchorage RecordingDistrict; " (lN o P.10393Boa
8
under no circumstances should this data hereon be used for No. `0�
the construction or establishing boundary or fence lines. �'.'-o0,,„,•..B(Zo j/ •;;;;
rofassionat`ac
APB Land Surveying 2S '° Upper Eagle River Estates Subd. ASBUILT SURVEY SHEET
SCALE IN FEET Lot 5A, Block 1 Doug Hanson 1 /
12204 East Prince of Peace Drive As Depicted on: Plat No.78-159 20321 Raven Drive
Eagle River,Alaska 99577 of
Anchorage Recording District Eagle River,Alaska 99577 / 1
(907)227-1361 GRID: NW+0256
Surveyed:August 11,2014 DRAFTED: RWR CHECKED: 10, APPROVED:
Cerfift"O 40ritting In
by
COC CC. @r
SULLIVAN WATER WELLS
P.O. BOX 670272, CHUGIAK, ALASKA 99567 -TELEPHONE 688.2759
OWNER OF LAND:
ADDRESS:
LEGAL DESCRIPTION: J pf%.2 /-r I[ s,a �' A KtZ
r=s.— /3c_K / 4,t i $1
DATE: -7 / J y/D S'
PERMIT NUMBER: _,0 FL/ t C Date of Issue - L -0y
TAX IDENTIFICATION NUMBER: QY-q -L- 0-4
Is well located at approved permit location? (.Vl^S'j No
Method of Drilling: L3�rotary O cable tool
Depth of well: 33 �� Y -
Casing Type yscE7i Wall Thickness -25Z inches
'feet
Diameter—6 Incinches, depth 36 �
Liner Type:
Casing Stickup Above Ground: °� feet
Static Water Level: Qj I feet
Recover Rate: c?D gpm
Method of Testing: -4j1?
Well Intake Opening Type:n end O open hole
O Screened; Start feet Stopped feet
O Perforations Startfeet (topped
Grout Type: Aj' r""te' Vo/r d
lume
feet
Depth: from feet, to � O feet
Well Disinfected Upon Completion? &A< O No
Method of Disinfection: Cd see...,,= f 101ryi
Comments:
rZ S
J
0-4b,)t S'i rGC,tj0
_X,) 6jST
��i�.c.J,�/r✓'
Drillers Name
CC A. F ,F,444 r tr4.,.t
ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority. Municipality
of Anchorage: Department of Heath & Human Services and/or Department of Environmental Conservation. Matsu Borough:
Department of Environmental Conservation.
t d 69LZ 299 L06 SIIeM JeJEM uenlllnS e60:60 90 9Z BnV
ARCTIC PUMP & WELL INC.
Fl Jim Sullivan, CPI
ti �! PO Box 770197
I' Eagle River, AK 99577
�i a ewa (907) 688-2510
(907)258.2510
(907)745-2510
a+L,n'cl, imet
Pump Installation Log
Well Drilling Permit Number: SW080110
Parcel Identification Number: 050-781-07
Date of Issue:7-8-08
Legal Description:upper Eagle Property Owner Name & Address:
River EST Doug Manson
Lot:1 20321 Raven DR
e • Ps.tn River A1C QQC77
Pump Installation Date: 7-16-08
Pump Intake Depth Below Top of Well Casing:351 Feet
Pump Manufacturer's Name: Dempster
Pump Mode1:M-75
Pump Size: 11/2 hp
Pitless Adapter Burial Depth: 10 feet
Pitless Adapter Manufacturer's Name: Baker
Pitless Adapter Installer: Arctic Pump & Well, Inc.
Well Disinfected Upon Completion? Yes
Method of Disinfection: Chlorine
Comments:
Pump Installer Name:
Arctic Pump & Well, Inc.
Arctic Pump & Well, Inc.
Page I of I
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-SiteWater& Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WATER SUPPLY PERMIT
Initial
Date Issued: Jul 08, 2008
Expiration Date: Jul 08, 2009
Permit Number: SW080110 Parcel ID: 050-781-07
Legal Description: UPPER EAGLE RIVER ESTATES BLK 1 LT 5A
Design Engineer: 0000 ZZ - NONE NEEDED Site Address: 020321 RAVEN DR
Owner Name: DOUGLAS HANSON Lot Size: 46207 SO. FT.
Owner Address: 20321 RAVEN DRIVE Total Bedrooms: 4 Permit Bedrooms: 4
EAGLE RIVER. AK 99577 -
This permit Is for the construction of:
❑ Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy E Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours). ( Not required for a Water Supply Permit only).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By.
Issued By:
Date:
Date: Z,k_a�?
J\lunicipality of Anchorage
- Development ServicpS:Department
Building Safety Division �.
On -Site Water and Wastewater Program „ r,
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.orglonsite
(907) 343-7904
ON-SITE SEPTICMELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D.
Property owner
❑
-
-4 C61 - U A
Day phone �� '��a
;�oso
ts)
) lJ���l
�'� �� I�N`Jo�1
Mailing address Zip Code
Site addressO
Legal description (Sub'd, Block & Lot)
Legal description (Township, Section & Range)
Lot Size y(p r ;?D 1 Sq. Ft.
THIS APPLICATION IS FOR (®all that apply):
Absorption Field
❑
Septic Tank
❑
Holding Tank
❑
Privy
❑
Private Well
Water Storage
❑
I certify that the
SingleU61 y C
[
/`
(Signature of
C-fZ- ZiD Code
Number of Bedrooms
THIS APPLICATION IS AN:
Initial �
Upgrade I�
Renewal ❑
above information is correct. I further certify that this application is being made for a
ivellinq and islin accordance with applicable Municipal Codes.
2rdWdl`h&7
owner or authorized agent)
Permit/Rush Fees:
HSr1 ` c Waiver Fees:
Date of Payment: T/ r 8 Date of Payment:
Receipt Number. Receipt Number:
(Rev. 11/05)
MUNICIPALITY 01' ANCHOFIAGE
DEPARTMENT Or HEALTH AND HUMAN SEIIVICES
• Environmental Health Division
025 ••L•• Street, Anchorage, Alaska 99502, Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/ON WELL INSPECTION FIEPOFIT
,a nV
1I )ras.
Z0.3 UE/v�2
ur E:al I'Cuml ND
L0722�/
EEGAI DESCa,e DD
_pS Iinipx/ SuDdvnW�/
1�41U
TANKS
DI L'curoymx
L
1 SEPTIC L.) HOLDING
1 /�Slmalr,
Gn'ticd,y "•gallons
'v B ml
No. al LUrnpuNnWlls
TYPE OF SYSTEPA
f TRENCH ❑ OED ❑ W. DRAIN ❑ OTHER
FIELD
LC a r to t •pe Dplloln I,pin r lolal Dep;n bwll onyln;a ylaoe
r .p..a'Wnna S
FT —�� --- FT
1, dJ.r•] Joow onymJ, y,aUr
Gra.el 0,1,111Ut'nvaln ppe
�) r♦
1:7— GT
DISTANCES
TO
SEPTIC
AOSORPTIOU
WELL
FROM
TANK
FIELD
WILL
/20 r
/30
4 ,
IWill Up,•.
FT
F
•��sla u� —_
_
n
LOT LINE
FOUIIOATION
/2'
93 '
AS-DUILI GIAGAAM Ibhuw loranun ur ooa, xrpec ss s:cm, prop,+ls wws. ,ovncu;.on
V
.®
iEt.1t.RKS: _� g U�1LE
@ C1UujH -
_ ETI/
�E Cale:
11"T.U�liunaf,YllrDt,yU,db
!/ATE2 . i191�/c//ZZJE'/� TO
S & 5 ENGINEERING
I ttrtily IhJI leis insyccliul was y:rlunu^J Duurrliny to 7:1
.17034 Cac to River Loop Road No. 204
fr,4nlcip114V41%FFIG't:'P;sd1E41E1E°4057%° —
Itea,lh UepadmeDt Approval: _ _. fate.—
119 A7a51
mmm
ENGINEER 4 SZAL
:tt;1 �!y;✓ c.
w.a• i E.o t•. rr...j
J. FLs. 1457•d JlE�f;•�.r.
4 �j>•aa ff�r•r: A�°
I o�' 11 fUp •OF~ «l� ��4�
2, ,5 _—FT
la a ansogn�ou uea
�.�rvp,.l onn•cy On rdu�yl
_2 _LZ60 so FT
,-=-,a pa „
Urslpu:C ar.laeen I:n•••.
p�pu n•.4�na1 �—
D3o35�_�vC
Odle In51JneU
__
WELLS 1571h/G
PRIVATE ❑ OTHER IIAenlitvl
�.I.,t�nn J4yn IA,U.CI
IWill Up,•.
FT
F
•��sla u� —_
Dale im:aud
n
V
.®
iEt.1t.RKS: _� g U�1LE
@ C1UujH -
_ ETI/
�E Cale:
11"T.U�liunaf,YllrDt,yU,db
!/ATE2 . i191�/c//ZZJE'/� TO
S & 5 ENGINEERING
I ttrtily IhJI leis insyccliul was y:rlunu^J Duurrliny to 7:1
.17034 Cac to River Loop Road No. 204
fr,4nlcip114V41%FFIG't:'P;sd1E41E1E°4057%° —
Itea,lh UepadmeDt Approval: _ _. fate.—
119 A7a51
mmm
ENGINEER 4 SZAL
:tt;1 �!y;✓ c.
w.a• i E.o t•. rr...j
J. FLs. 1457•d JlE�f;•�.r.
4 �j>•aa ff�r•r: A�°
I o�' 11 fUp •OF~ «l� ��4�
ND
1189 54 00 E 30oD.2t CM .go',
• M
to' wnuri KAEUTs
� wo,2g35�
N
300. *X1
A Q�
g8a" rao' 2loaW � t
s9► ». sef. er�.Rc i:si
FPTm:g..� Pl=
T�k� F F
v 'CO
9 Me 41
2)a0.24`
O" W 30121
A**%p"*4V
�7
•Proposed
Weil g'
SE o eK•
well
Z
T -
i"N5o'
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES ©fo — 7Bl -- O 7
Environmental Health Division
825 "L" Street, Anchorage, Alaska 99502, Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Name
coomi;`So
TANKS G/ %
DISTANCES
SEPTIC
❑ HOLDING
TO
FROM
SEPTIC
TANK
ABSORPTION
FIELD
WELL
A°dress n
C C �c�7
. / (� U ft1 O2- h . - Z
WELL
�Z t7 r
/3� /
Material ^
u\'
Zee
Phones
d - 0'72 Z
Permit No. No. of Betlrogms
1990/549 zz
LOT LINE
//�
Go rT
/O r�
TYPE OF SYSTEM (�
LEGAL DESCRIPTION
Lot
cS�
Block
Subdivision
GI J!% L (/• EiT.
FOUNDATION
/Jg
S
/ FT LIQ FT
Township, Range. Section
n i / /, / i / �/
' V (
AS -BUILT DIAGRAM
dinveway. water bodies.
(Show location of well,
etc.1
septic system, property
Imes, foundation.
Gravel length/ braver wwm
`L0 9 FT 2,,S- FT
Total absorption area Distance between lines
A980 SQ FT /0,-/— FT
Number of hoesSoil rating Pipe material
2 Z60 SQ FT 03o3/- 6167
Install to Installed
e WELLS j5X(57/-h/6:
p PRIVATE ❑ OTHER (Identiiv)
I Installer
IREMARKS:
Date Installed.
FT
014
n
I7A
I(JppI I .I — L /G/�J /7 °� SCJ �t /`i wL Inspections P® orr9gd by: m
G LLJ r /r�E'k% s0Z_ L G /T1 0 /t% V Date:
S & S ENGINEERING certify [hat this inspection was performed according to all
Municipal al77034 Eagle River Loop Road No. 204
�tl Sta� �l�P:sd9$49F�°9�5�e C
Health Department Approval: �� —Dane: 30 V
c -u 10 (Jrbp)
TANKS G/ %
x]
SEPTIC
❑ HOLDING
Ma Iacwler
Capacity In gallons
eAll
/2 6_0
Material ^
u\'
Zee
/
No. of compartments
TYPE OF SYSTEM (�
rXTRENCH
❑
BED ❑ W. DRAIN ❑ OTHER
Depth to pipe bottom from
r Total depth from original grade
original grade
S
/ FT LIQ FT
Fill added above original grade
Gravel depth beneath pipe
FT
Lj FT
Gravel length/ braver wwm
`L0 9 FT 2,,S- FT
Total absorption area Distance between lines
A980 SQ FT /0,-/— FT
Number of hoesSoil rating Pipe material
2 Z60 SQ FT 03o3/- 6167
Install to Installed
e WELLS j5X(57/-h/6:
p PRIVATE ❑ OTHER (Identiiv)
I Installer
IREMARKS:
Date Installed.
FT
014
n
I7A
I(JppI I .I — L /G/�J /7 °� SCJ �t /`i wL Inspections P® orr9gd by: m
G LLJ r /r�E'k% s0Z_ L G /T1 0 /t% V Date:
S & S ENGINEERING certify [hat this inspection was performed according to all
Municipal al77034 Eagle River Loop Road No. 204
�tl Sta� �l�P:sd9$49F�°9�5�e C
Health Department Approval: �� —Dane: 30 V
c -u 10 (Jrbp)
MUNICIPALITY OF ANCHORAG
Department.. of Health &. Human Services;
825 I_. Street, Anchorage, Alaska 99 501 343-4720
'.0
O N -- S I T E:: S E 41 E_ R
Permit- Numbeara 880148 Upgrade_
Date Issued; 08/0 2/88 Engineer Designed
Owner .game. DOUG) HANSON
Owner Addreessn 20321. HAVEN DRIVE
EAGLE RIVER, AP': 99577
P E R lel I T
Parcel. Idg 050-701.--07
Lot Legal, Subdivivi.ona LIF'PE:R EAGLE FIVER ES
Section: 17 Townships 14N Rangel
Lot Size 46247 (scl.ft.. or acres)
Max Bedrooms; This Permit; 4 Total Capacityg
/f'
E::Z'5'd10*4
4' 6T,
Day Phone;
696-0722
Lot., `,A Blocks 1
1W
4
SEPTIC TANKN Minimum total septic: tank capacity: 1.,250 gallons. Each septic
tank dust have at.. least- 2 compartments. Depth to top of septic. tank (s) <:: 4,0
§Ncat requires 7.n5iiLd3.aAt:LCH-1 over tank(s).
INFORM D.,H,H.S. PRIOR TO IST & ?ND INSPECTIONS BY ENSINEER, It:
AFTER OFFICE HOURS, CALL... 343-46SI AND LEAVE A MESSAGE.
CONSTRUCT PER ENGINEERS ATTACHED APPROVED DESIGN.
PERMIT EXPIRES 12/31/88.
PERMIT VALID FOR A SINGLE FAMILY RESIDENCE:: ONLY.
I CERTIFY THATF
1.:. 1 am familiar with the requirements for on-site sewers and wells as set
forth by the Municipality of Anchorage (MINA) and the State of Alaska.
2. I will install the system in accordance with; all MOA codes and regulations,
and in compliance with the design criteria of this, permit.
3.: I wi.3.l adhere to all I°IC1A and t-at:.<:at.e of Alaska requirements for t..hc:r set- hack:
distances from any existing well, wastewater disposal system or public
sewerage system on this or any adjacent or nearby lot..:
4. 1 understand that this permit, is valid for a maximum of 4 bedrooms. I
also understand that the capacity of the total system is 4 bedrooms and
any enlargement will require an additional permit.,
Si.c'-lnec:l; DATE„
(Owner) I:iOUia -LANG hl Q
Icst.tsx::l T:ry, .3
-----------------------
PERFORMED
LEGAL DESCRIP
DEPTH
.I �=Tl
1
b'( -
2
'i<2
3 d
4 0
5
6
8
6
9
,o
12-
13-
14-
15-
16-
17
2 1314151617
18-
19-
20-
Municipality
81920
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
!AM
61111-266 ��le
MUNICIPALITY OF ANCHORAGE
DEPT. OF HEALTH &
ENVIRONMENTAL PROTECTION
AUG 121988
SLOPE
R E C E I V E4GROUND WATER A j i
R')Alyi of ``D%
COMMENTS —/ CJ v //"✓c - "
PERFORMED BY: S & S ENGINEERING
17034 age littyar ®op Ka
ACCORDANCE WITSeeb Rt"IF MMIMSPAPYL
72-008 (Rev. 4/85)
6..............
i�►rt A. Strider
Ma, ilb7%
DATE PERFORMED: T/
SIT PLAN
ENCOUNTERED?
S
IF YES, AT WHAT /) L
f� t O
DEPTH? p
E
i
Depth to Water Ap�e /tl6//�
Monitoring? � Date:
5
Reading Date Gross Net Depth to Net
Time Time Water Drop
/L
PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER
TEST R BETWEEN FT AND FT /
I CERTIFY THA THIS EST WAS PERFORMED IN
W No. 204
3UIDELIN€N f. FECT ON THIS DATE. DATE:
0
e Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
PERFORMED FOR: 12-Ly G �k:� DATE P
LEGAL DESCRIPTION: I.S"A ?P .I jpt7LR Lfjownship, Range, Section: T
2
2
l
3 e O
4 Or
5
op7
8
9 DO O
10-
11-
12
0 11 12
13-
14-
15-
16-
17
314151617
18
19
20
COMMENTS
9-W611— e5+-1
C-
PLAN
WAS GROUND WATER
ENCOUNTERED? O
IF YES, AT WHAT
DEPTH?
DepthYom' to Water Alter
Monitoring?
MonilerinpY Date:
PERFORMED BY: S & S ENGINEERING
17034 Fagle River
ACCORDANCE WITHEgIF r4V4rT/.10tIAF*
72-008 (Rev. 4/85)
Y
PERCOLATION RATE 21 (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN FT AND L� FT
i CERTIFY THAT THIS TEST WAS PERFORMED IN
ON THIS DATE. DATE:
Municipality of Anchorage s
Department of Health and Human Services dhh5
Tom Fink, 825 "L" Street
Mayor P.O. Box 196650 Anchorage, Alaska 99519-6650
August 24, 1988
Robert A. Shafer, P.E.
S&S Engineering
17034 Eagle River Lp., Suite 204
Eagle River, Ak. 99577
Subject: Lot 5A Blk.l Upper Eagle River Estates
Dear Bob,
The purpose of this letter is to clarify the position this
department has regarding the issuance of the Health Authority
Approval ( HAA ) for the subject lot.
It has long been the department's position that if no records
are available, either from the current owner or our files,
that an adequacy test be run and the size of the septic tank
and absorption area be verified. This could result in having
the septic tank exposedto assess its condition. When such
information is provided by the engineer the department is
ensured of having reliable information with which a HAA can
then be processed. This was not requi-red in this case,
however, for the following reasons:
1. In January of 1978 the septic systems components were
identified and noted for our files by Mr. Les Buchholz, of the
Dept. of Environmental Quality, now DHHS.
2. Your investigation reported
of conpartments, and method of
tank, as provided by the owner.
information on the size, number
construction for the septic
3. The adequacy test on the absorption area was satisfactory
for a four bedroom residence.
Although a portion of this information was obtained from the
owner, Mr. Bayless, there appeared at that time to be no
reasonto doubt his word. As Mr. Bayless was the installer he
would, therefore, be the most knowledgeable person to contact
on the systems installation.
Since the last HAA, however, many deficiencies have come to
light, the foremost of which is that the dwelling is in fact a
duplex. As this department has no authority to review
multifamily dwellings we will have to withdraw our previous
approval. Among the other discrepancies are the facts that no
permit was ever obtained for either the original septic system
or the upgrade, performed at a later date by Mr. Bayless.
Neither did Mr. Bayless arrange for any component of the
system to be inspected. If there had been an inspection a
manhole cover would have been installed on the septic tank or
the installation disapproved. It is regrettable, though,
that these facts were not known until the system failed and
required yet another upgrade.
As stated earlier this department must rely on the information
which is presented. As such there is an inherent dependence
upon the investigation of the engineer. It is his
responsibility to ensure that all the information is verified.
I trust this will clarify the process by which this department
issued the approved HAA, for the subject property, on 2/29/87
and again on 3/16/88 and why we will now withdraw same. -If --
you should need any further information please don't hesitate
to contact this office.
Sincer7%
fFJ//J
Daniel N. Bolles
On—site Services
cc: Lee Browning, P.E., Manager
Environmental Services
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
DIVISION OF ENVIRONMENTAL SERVICES
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL
OF ON-SITE SEWER AND WATER FACILITY
264-4744
5o
7 g�
Application Date
GENERAL INFORMATION (MUST BE COMPLETED PRIOR TO SUBMITTAL) _.
(a) Legal Description (include lot, block, subdivision, section, township, range)
Z_ S /-i / 1-r / (il/O0E1P--
Location (address or directions)
Co 2 '/0 /a �&_- w ' /c /g vim' ti
(b) Property OwnerT/• -.&-A V /e ; S Telephone: Home 6 9 37 Business
Mailing Address 2032/ D/e_ 6e>x- A, /F 5- 7"7
(c) Lending Institution
Mailing Address
Telephone
(d) Real Estate Company and A�gent� 6
Address Sb / ' L/ C y"fz� `—
Telephone 7 /off
(e) Mail the HAA to the following address: or: Check here ❑, if hold for pick up.
List contact person and day phone number below.
$ s, S ENGINEERING
17034 Eagle River Loop Road No. 204
2. TYPE OF RESIDENCE
Single -Family
Number of Bedrooms -
3. WATER SUPPLY
Individual Well Community ❑ Public ❑
02 o,=2r� /3 y
G/rV4/a B�t-�
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
4. SEWAGE DISPOSAL
Onsite Public ❑ Community ❑ Holding Tank ❑
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
Page 1 of 2 72-025 (Rev 8/861 Front
5. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health
Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained
from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on
the date of this inspection.
Name of Firm Telephone
S & S ENGINEERING
Address j7034zygle-WYer--L rRoad-
Date Eagle River, Alaska 99577
6. DHHS APPROVAL
Approved forL—L-612 bedrooms by ate
Approved _. &/ Disapproved Conditional
Terms of Conditional Approval
CAUTION
w; r
4ez =1! l if
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval
certificates based only upon the representations given in paragraph 5 above by an independent professional engineer
registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in
order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data
before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional
engineer's work.
Page 2 of 2
74-025 (Rev 8/861 Back
MUNICIPALITY OF ANCHORAGE (MOA)
HEALTH AUTHORITY APPROVAL (HAA)
CHECKLIST - FEBRUARY 1984
MUNICIPALITY OF ANCHORAGE 284-4744
ENVIRONMENTAL SERVICES DIVISION UC,—x SA �jt
Legal Description:
MAR 1,6 1988 �P��� t y1.���s�
A. WELL DATA RECEIVED
Well Classification ✓Aqr-' If A, B, C, D.E.C. Approved (Y/N) 01A
Well Log Present Date Completed A�19 to Yield
Total Depth z" Cased to (IC2 Depth of Grouting
Static Water Level
Pump Set At
el
Casing Height Above Ground Sanitary Seal on Casing ON)
Electrical Wiring in Conduito'N) Depression Around Wellhead (Yx@)
Separation Distances from Well: /
To Septic/Hafd Rg Tank on Lot Sb On Adjoining Lots ��I+
To Nearest Edge of Absorption Field on Lpt � r On Adjoining Lots 1,I4-
To Nearest Public Sewer Line �7a' To Nearest Public Sewer 2� 1+
Cleanout/Manhole P To Nearest Sewer Service Line on Lot
Water Sample Collected by trF��G' ; Date —
Water Sample Tpst Results
Comments
'r� ��► _�� ��] ca_
B. SEPTIC/l4NG TANK DATA
Date Installed��� )� Size No. of Compartments
--tc-
Standpipes YJN) — Air -tight Caps(IN) ___yFoundation t�Ieanout (Y4W
Depression over Tank (Y41V tj Date Last Pumped
Pumping/Maintenance Contract on File (Y/N) 1J for
Holding Tank High -Water Alarm (Y/N) I A Temporary Holding Tank Permit (Y/N) �
Separation Distances from Septic/+iIok ing Tank: t
To Water -Supply Welles To Building Foundation
k !.
t _,r
To Property Line �� To Disposal Field Ud
To Water Main/Service Line
Course
Comments
Page 1 of 2
72-026 IRev. 8/861 Front
To Stream, Pond, Lake, or Major Drainage
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata JVD" Type of System Design '2 --
Date
Date Installed Length of Field �1v1 1 Z
I I I
Width of Field — Depth of Field 1�
Gravel Bed Thickness
Square Feet of Absorption Area Standpipes Present �J 1)
Depression over Field (Y/W N Date of Last Adequacy Test
Results of Last Adequacy Test
Separation Distance from Absorption Field:
I I
To Water -Supply Well To Property Line 3�
To Building Foundation
Lot
2-I
On Adjoining Lots
To Existing or Abandoned System on
Ik
To Water Main/Service Line \ -4 To Cutgank (if present)
To Stream/Pond/Lake/or Major Drainage Course tJ 1111
To Driveway, Parking Area, or Vehicle Storage Area Sb
Comments
D. LIFT STATION
Date In `
Size in Gallons��
"Pump On" Level at _
High Water Alarm Level at
Tested for
Electrical Codes (Y/N)
Comments
Dimensions
Manhole/Access (Y/N)
— "Pump Off' Level at
'" Check Permitted Bedroom Rating Against HAA Request "
Vent(Y/N)
Cycles during Adequacy Test. Meets MOA
I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection.
Signed S & 5 ENGINEERING [late �7 — 15 —LS
17034 Eag a ver 00p oad 1Vo. 04
Company __Eagte Uver Alayka_M77_ MOA No.
Receipt No.
Date of Payment _ is
p<
Amount: $ �v ine al
Page 2 of 2
72-026 (Rev 8/861 Bnck
b . Y
CHEMICAL & GEOLOGICAL LABORATORIES OF ALASKA, INC.
5633 B STREET ANCHORA(3E, ALASKA 99518 TELEPHONE (907) 562-2343
FEDERAL TAX ID # 92-0040440
ANALYSIS REPORT BY SAMPLE for Work Order f 5583
Date Report Printed: MAR 14 88 @ 15:51
Client Sample ID:LSA, B1 UPPER EAGLE RIVER Client Name : S & S ENGINEERING
PWSID :UA Client Acct SNSENGP
Collected MAR 10 88 @ 16:15 his. P.O.f NONE REC D
Received MAR 11 98 @ 13:00 his. Req f
Preserved with :ICE Ordered By
Analysis Completed :MAR 11 88 Send Reports to:
Laboratory Super,��v.ii�ss,,orr`:STEPHEN C. EDE 1)S & S ENGINEERING
"
Released By : G. 6?4/ 2)
Special
Instruct:
Chemlab Ref f: 9349 Lab Smpl ID: 3 Matrix: Water
Allowable
Parameter Tested Result/Units Method Limits
-------------------------------------------------------------------------------------------------------
NITRATE-N 2.2 mg/l EPA 353.2 10
Sample ROUTINE SAMPLE
Remarks:
.............................................................. .
1 Tests Performed See Special Instructions Above UA=Unavailable
HD- None Detected See Sample Remarks Above
NA- Not Analyzed LT -Leas Than, GT=Greater Than
7-
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
DIVISION OF ENVIRONMENTAL HEALTH
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL
OF ON-SITE SEWER AND WATER FACILITY
264-4720
Application Date -20
0 7
1. GENERAL INFORMATION
(a) Legal Description (include lot, block, subdivision, section, township, range)
�o� 6 IGC /,�0�/t €IFiGGE' &IC)elC Es T. ��12 Z_
Location (address or directions)
L'oe GcJvin/, ,/
(b) Applicant Name?'j- 6A► eleSS Telephfolne: Home 697 37V 7 Business
Applicant Address _2 03 2 I Jl. A(1 l;; N O/Z• Qct OL /4, LE. 9l/f %
(c) Applicant is (check one): Lending Institution ❑ ; Owner/43eild X, Buyer ❑ Other ❑ (explain);
(d) Lending Institution Telephone
Address
(e) Real Estate Company and Agent
Address
Telephone —
�L, D
(f) -Mai' the HAA to thV21l91 jQGff4&fNG
17034 Eagle River Loop Road No. 204
Eagle River, Alaska 99577
2. TYPE OF RESIDENCE
i
Single -Family, Multi -Family ❑ Other
Number of Bedrooms
3. WATER SUPPLY
Individual Well Community ❑ Public ❑
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
4. SEWAGE DISPOSAL
Onsite Public ❑ Community ❑ Holding Tank ❑
Note: If communitywell system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
Page 1 of 2 'l2-025(,1,84)
IMLL) SZo-zi
Z to Z abed
laom s,jeau!6ua leuo!ssaloid
aq; u, suolss!wo ao saoaaa jo; olq!suodsai lou sl a6eaogouV io A3!led!o!unvi agl'panss! si aleolpPeo a aao;aq elep azlleue
ao suo!loadsut lonpuoo lou op d3H(] to saa (oldw3 sluawaAinbaa awls Pae leJap U1eo a1 1S laq; u! paaals baa alaul6a
u
6u!pual 11agl pue sawoq to siasegoind of /�saUnoo a se s!gl saop d3H0 gl ' V 3
leuo!ssa;oid luepuadepu! ue /q anoge g gdei6eaed u! uaA16 suo!leivasaidai ag; uodn Rlolos paseq saieo!3!Uao lenoiddy
Aluoq;ny g11eaH sonss! (d3H(]) uo!loa;oad leluaLuuoa!Au3 pue glleaH to ;uawlieda(] abejogouV io /l!led!ounlN aqi
NOilnVo
E"W4v'i v:,2
VC 0
leuoglpuo0
lenojddV leuo!1!PuoO to swJal
panoiddesi(]Panoiddy
a3e0 � Aq swooapaq j� / �" aol panaddy
J t,
v
lea !R,',;
p✓ F asa F<„'4 r �
;A$��y�^tea:
IVAOUddV d3H0 '9
LLS6S e�sely'JaA;a 016e3 ssaapPV
auogdalal WAIA to aweN
'JNI833NI9N3uo� adsu! s!ql 10 aleP Gull
uo 10049 u! suo!;eln6ai pue'saoueu!pao'sapoo a;eiS pue led!o!unlN Ile ql!M aoue!ldwoo ui si wals/s lesods!p aa;emalsem
ao/pue (lddns aalem al!s-uo Gull 'uo!3oodsu! pue U01IL511SOAUI !w uioJJ pue sapl a6eaogouV to Al!led!o!unyi aqi ww;
paulelgo uollewjolui aqi uo paseq legl /3uaA aaq>ani 1 Ulejaq paleo!pui ain3onj;s io AAJ pue swoapaq to jagwnu aql aol
a;enbopepue leuo!lounl'aless!wals{slesods!paaiemalsemao/puellddnsjalema;!s-uoag11eg1 smogslenoiddV (1!joglnV
1411130H s!ql to uoge6gsanu! /w legl (3u8A I 'molaq umogs alep uogeP!leA aql to se pue olaaag paxgle leas ALU /q paipliao sV
N0I1tlWH0zlNI ONtltlltlO'HOUV3S 3-1!.4'SJ.S31'SNOI103dSNl ONIOIAOHd WHId ONIH33NION3
.9
MUNICIPALITY OF ANCHORAGE
n 1 ENVIRONMENTAL SERVICES DIVISION
MUNICIPALITY OF ANCHORAGE (MOA)
HEALTH AUTHORITY APPROVAL (HAA) FEB 12198%
CHECKLIST - FEBRUARY 1984 t
264-4720 C E! V E D
Legal Description: t;�/L Lam+ S V7Nq _
A. WELL DATA
Well Classification S• F.' If A, B, C, D.E.C. Approved (Y/N) '`/IA
Well Log Present (Y& Date CompletedI �7-6) APP A&X Yield (0 L P'N f
Total Depth %&' Cased to `fO 4 ✓
r �
Depth of Grouting
Static Water Level Zr Pump Set At %
Casing Height Above Ground —
Electrical Wiring in Conduit/N)
y
Sanitary Seal on Casing N)
Depression Around Wellhead (Y&
Separation Distances from Well:
To Septic/Holding Tank on Lot SIC) ; On Adjoining Lots (jp r4-
r r
To Nearest Edge of Absorption Field on Lot 00 ; On Adjoining Lots /oo 4
To Nearest Public Sewer Line A To Nearest Public Sewer /
Cleanout/Manhole/To Nearest Sewer Service Line on Lot 2 $ _74-
Water
fWater Sample Collected by d <S (- N U N��G Date
Water Sample Test Results
Comments
A , .,li
r7/yr,5�,<_ T �� aSs5
B. SEPTIC/HOLDING TANK DATA SS�2(Z /XOIZ� D( Sof C4
Date Installed / 9 "� Size /ZSl7 "I- No. of Compartments 10
Standpipes (O k Air -tight CapsaN) Foundation Cleanout (YCN�i)
Depression over Tank (Y,6P/ Date Last Pumped
Pumping/Maintenance Contract on File (Y/N) �/A ; for
Holding Tank High -Water Alarm (Y/N) �Izq Temporary Holding Tank Permit (Y/N)
Separation Distances from Septic/Holding Tank:
' r
To Water -Supply Well 4- So To Building Foundation /e
To Property Line 61's To Disposal Field /'0'
To Water Main/Service Line lo 4 To Stream, Pond, Lake, or Major Drainage
Course SIA
Comments �A e _ lN1i of JKSi L
QJ cSXS x e7'5'J14 3-ca���v
Page t of 2
72-026(11/84)
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata Type of System Design
Date Installed — Length of Field /(o e— Z!
Width of Field — r , �Z /` Depth of Field - /Z/
Square Feet of Absorption Area
Depression over Field (Y&
Results of Last Adequacy Test
Gravel Bed Thickness it
%By Standpipes Present (ON)
Date of Last Adequacy Test
S.A i i5F✓tc�K j `'02 4{/3)2
Separation Distance from Absorption Field:
To Water -Supply Well eco!
To Building Foundation
Lf Zr
Lot /� /
To Water Main/Service Line
To Stream/Pond/Lake/or Major Drainage Course _
To Driveway, Parking Area, or Vehicle Storage Area
Comments
D. LIFT STATION
To Property Line 3Y
To Existing or Abandoned System on
On Adjoining Lots 3o f
To Cutbank (if present)
Date Installed _ Dimensions
Size in Gallons Manhole/Access (Y/N)
"Pump On" Level at .'Pump Off' Level at
High Water Alarm Level at Vent (Y/N)
Tested for
Electrical Codes (Y/N)
Comments
** Check Permitted Bedroom Rating Against HAA Request **
Pumping Cycles during Adequacy Test. Meets MOA
I certr`X&8tgAjyft4JNFW,verified,orconformedtoallMOAandHAAguidelinesineffectonthedateofthisinspection.
Signea7034 Eagle River Loop Road No. 2*ate L-'
Eagle River, Alaska 99577 ,
Company MOA No.�`r
Receipt No. 'J 000k —t 1p�
Date of Payment a-
Amount: $ I Mee, �—
Page 2 of 2IN
72-026 (11/84)
I --.1 MUN
n I-Aw DEPARTME 01
3 2 5
41: Time ���_�11.__ � 1 2:
PALI(Y OF!Received:
SAG EAGLE RIVER AREA
LTi ANDMENr PROTECTION
et, A oAlaska 99501
v -41
DatDecember 13, 1977
Time
#3: Time
DateI-/�%j;j� Date Date
Insp n.11/ir�1 _ Insp I:nsp
REQUEST FOR APPROVAL OF INDIVIDUAL SEWER AND WATER FACILITIES
1. Lending Institution Request: Alaska Bank of Commerce % Carol Williams
Mailing Address: Pouch 7-012 99510 _ _ Phone: 279=5641/317 _
2. Property Owner: Tommy J. Bayless — ____ Phone: 344-4543 _
aul
Mailing Address: _NHN Wren — 376-5362
3. Legal Description: SZ Lot 5 Block1 qpeK Eagle River hi=s Subdivision
4: Single Family Residence: (x)
Multiple Family Residence: ( )
5
L
Number of Bedrooms: Four
Number of Bedrooms:
Well System: Individual Well (x) Community/Public System ( )
Permit # _ Depth of Well — __ Well Log on File ( )
Construction Bacterial Analysis— _
Sewage Disposal System: On-site System (x) Public Utility ( )
Permit # _ Installed InstVerj--(
Septic Tank Sizev Mkn'V�icurer
Absorption Area _ o ate _ Material.
7. Distances: Well to Septic Tank
to Seager Line Nearest Lot line
to Nearest Lot Line
to Absorption Area
Absorption Area
PAWY OF
GREATER ANCHORAGE ARL/ BOROUGH 1o1UNI)EpT. of HEATH It vF
o
Department of Environmental Qual i ty VIRU`pANTAL PROTti-i1O�
3330 "C" St., Anchorage, Alaska 99503 - 274-4589
FOROF
INDIVIDUUALSSEWER &PWATERLFACILITIES
1. Type of Inspection: CMRO VA FHA CONV_
2. Property Owner: Bayless,'Tommy J.
�.
Mailing Address: NHN wren Eagle R ,P,' Au Day Phone 344-4543/376-5:362
3. Name of Buyer: -SElf
Mailing Address: Same as above Day Phone ;
4. Name of Lending Institution.: Alaska Bank of Commerce
Mailing Address: Pouch 7012, Anchorage, A•k- Phone 279-5641 Ext. 317
(Processor Carol wfiilams),
5. Name of Realtor or Agent: NA
Mailing Address: Phone
6.. Legal Description: S 1/2 Lot 5, Blk; 1, Upper Eagle River Hts.
Location: Eagle.River, Alaska
7. Type of Facility to be inspected: well & Septic No. Bdrms. 4
8. Water Supply
Type of Supply: Public Utility Individual
If Individual, number of dwellings presently .served
If Individual, depth of well
9. Sewage Disposal -System
Type. -of System: Public Utility
If Individual, date of installation
Individual (on-site)
s,
Page. Two
�1
Department of Health and Environmental Protection
Request for Approval of Individual Sewer and Water Facilities
Legal Description: Sz Lot 5 Block 1 Upper Eagle River Heights Subdivision
Comments:
Af£adavit Attached: ( )
Approved
Disapproved:
Letter Attached: ( )
Date:
Date:
Department Worksheet:
v!
R&M CONSULTANTS, INC. 5024 CORDOVA Y BOX 6087 • ANCHORAGE, ALASKA 99502 • PH. 90]-2]9-0983 Y TLX. 090-25360
GEOLOGISTS
NNERS
SURVEYORS
January 17, 1978 R&M No. 851502
Tommy J. Bayless
SRA Box 6006
Eagle River, Alaska 99577
Subject: Adequacy Test on Existing Sanitary Sewer System; Lot 5, Block 1,
Upper Eagle River Estates
Dear Mr. Bayless,
On January J3, 1978 at your 4equest, we conducted a test of the septic $yftem
on the above described property.
During the test the �lquid level in the septic tank was monitored as water
was added to the sysPem. The measurements are summarized in the following
table:
Liquid Level Below Top Total Gallons
Time of Standpipe Added
—,--
12:30 8.50' p
12:48 8.40' 50
1:04 8.25' 75
1:31 8.15' 100
2:1.3 8.40' 100
2:25 8.50' 190
The meter used during the test was a Rockwell 5/8" standard water metev which
had previously been calibrated by R&M Consultants.
If the 3 -bedroom residence on the property is to house six people, the overage
load on the system can be expected to be 450 gallons per day or 0.31 gal,lofis'.
per minute. During the test, the system accepted 100 gallons in 115 minytes.
This indicates an average effluent acceptance rate of approximately 0.87 nn
gallons per minute eat the time of the test. AnY
ANCHORAGE FAIRBANKS JUNEAU V.I.E. WASILLA
January 17, 1978
Thomas J. Bayless
Page -2-
Since the house on the lot is occupied, we assume that the leach field was at
its normal degree of saturation. We can therefore conclude that the system
is disposing of effluent at an adequate average rate for a 3 -bedroom residence.
We appreciate this opportunity to be of service to you. Please contact us if
you have any questions concerning this test or this letter or if we can be of
additional service.
Very truly yours,
R&M CONSULTANTS, INC.
Gary E3: Smith'<L�Sy
Senior Geologist
GAS/kah
Jim McCaslin Brown Ph.D.
Head, Earth Sciences Department