Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
T11N R3W SEC 2 N2SE4 & N2SW4SE4
TIIN R3W Sec 2 N2 SE4 & N2 SW4 SE4 #020-101-06 LOT 2 � M cKiniIlet y I M /-\ U I M View Estates LEGEND R -O -W IROAD pe!}ERUIE 80 LOTS nr LAYOUT PLAN - OPTION 2 - - - - KID GRAPHIC SCALE 03/03/2009 08:56 9073453287 MW DRILLING PAGE 01/01 M -W Drilling, Inc. •P.O. Box 110378• Anchorage, AK 99511♦ •907-345-4000 • 907-345-3287 Fax* JobNo.: 05-118 Parcel No.: 020-101-06 Permit No. SWO50053 Groundwater tirell As -Built & Log •Well Owner: Harvest • Legal Dneription: Views of Promi, Construction • Use of I Fell. Domestic •Hole Depth: 180' •Casing Size: 6" ♦Cased TO: 8.95' ♦nfaterial: A53Steel •Drill Afethod: Air Rotary 5" 42' Schedule 40 Perf. •Yell Completion- Open end X Screen Per _ Method: *Screen/ Perforationdeseription: None ♦Grout lata: (3) Sacks -No. 8 bentonite granules • Notes: 6" Casing hung on boulder; nm and grout 5" after drilling to total depth. • Well Development: Afethod: Alr surge Notes:' ♦Stalk water level (SWL) 20' (above) (below) top of casing (TOC). • Welt yleld test at 4.1 gallons per minute (GPA01 ) for will, A g9. - of drawdown (DD) from static level (SWL). •Method. Airlift • Date of completion. 31 March 2005 • Pump Install: Well Loo _ f— hours Depth in feet from top of casing. Details of formntinna penetrated,size of mnterial color and hardness. _ 0 TO _3 Casing stickup 3 TO 6 Or anics _ 6 TO 180 Bedrock: gray/black, siltstone argillite, small water soaps in sporadic TO fractures TO .s' _..— TO _ _ TO TO ..., TO _ TO TO _ TO TO - WAYNE-ETWESTBER131- ft sldent -M--_ W.Drilling.-Ino, r-XM%0erlifiedCoAftccMr�-i. — ° Ceacaltte Nos, 19y !o(o!p TO Contractors Ucense No. 1000 03/02/2009 15:25 9073453287 MW DRILLING PAGE 01/05 M -W Drilling, Inc. *P.O. Box 110378*Anchorc9e, AK 99511• ♦907-345-4000 • 907-345-3287 Fox♦ Job No.: 05.118 Parcel No.: 020-101-06 Permit No. SWO50054 Groundwater Well As -Built & LoQ ♦ Well Owner: . Harvest ♦Legal peseNpGon: Views of Promi Construction •IloleDepth: 340' ♦CnsingSize. 6" •Cased To: ♦ Drill Method: Air Rotary ♦ Use of Well: Domestic 40.34' ♦Material: A 53 Steel Perj. • Well Completion- Open end X Screen Perforated Method: ♦Screen/Perjorationdeceription: None •GroutN'oles. (4.5)Sack3-No.8bentonitegnnu1es ♦ Notes: Drilled 8" to 401, tan 6" and grouted ♦ Well Development: Method: Air surge Notes: •static water level (SWL 94.1' (#b"V) (below) top of casing (TOCJ, ♦ Well yield teat of gallons per minute (GP,11)/geNontperaieur{6Pf1) for ;4-- hours wilit 26W+00% of drawdown (DD) from static level (SWL). ♦Method: Airlift • Date of completion: 06 April 2005 • Pump Install: Well i.on Depth in feet from top of Casing. Details of formations eenetrated, size of materint, color and hardness. 0 TO_ — 4 Casing stickup 4 TO 8 Or anics 8 TO _ 40 Bedrock: 20' some water 40 TO 200 Bedrock: gra lack, siltstone argillite, small water seaps in sporadic TO fractures 200 TO 220 Picked up more water in fractures , 220 TO 340 Bedrock: as above T — TOO --- — -- TO TO TO _ T'~ TO - AYNEM. &-MERG —, 'denti-M--VII-Drilling,-It1o.- .-NOWA Certified aoW-4 — * 0artificA!e Nos, (o(p i0 Corftctors License No.1000 TO _ To TO TQ 03/02/2009 15:25 9073453287 MW DRILLING PAGE 04/05 M -W Drilling, Inc. •P.O. Box 110378 *Anchorage, AK 99511• •907-345-4000 • 907-345-3287 Fax* JobNo.: 05-118 Per"INo.: 020.101-06 Permit No. SWO50052 Groundwater Well As -,built & Loi • WcllOwner., Harvest •Legal Description: Views of Proml Construction t. Use of Welt: Domewic •Hole Depth: 400' • Casing Size. 6" •Cased To: 40.05' ♦Material: A53Steel ♦Drill Method. Air Rotary _ pe{f. ♦ Well Completion- Open end X Screen Per — Method: •Sereen/Perforation deterfptiorr: None ♦Croutivates: (1)Sack- No. 9bentonite granoles • Notes: ♦ Well Development. Method: Airsurge Notes. •Static water level (SN2) 35.5' (above) (below) top of easing (TOC). q� ♦ Well y ield test at f .24 gallons per minute (GP,If)/gallon�A)for . n -r hours 11,11h 47 we% ofdrawdown (DD) from slafie level (S1111). •Afethod: -Airlift ♦ Date of completion: 29 March 2005 ♦ Pump Install. Well Log Depth In feet from top of casing. Details of formations penetrated, size of material, color and hardness. 0 TO 3 Casin sticku 3 TO 17 Sandy gravel: cobbley 17 TO 400 Bedrock: g /black, siltstone argillite, _ small water seaps in sporadic TO fractures TO ----�_ TO ---- __ TO TO TO TO _ TO _ TO TO QYNEE. WESTSERG Pmeldent, M-W-Dr1111nM4M —•i--HQWA Certified ContreoW-4- CeftitIcate_Nos._g9(da(o Contractors Ucense No. 1000 - TO TO TO MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water& Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519.6650 (907) 343-7904 ON-SITE WATER SUPPLY PERMIT Initial Date Issued: Mar 21, 2005 Expiration Date: Mar 21, 2006 Permit Number. SW050054 r_YrE s oF-P+to.wy8icf:�rsS arce 01-06 Legal Description: 4 Design Engineer: 0070 KND Engineering Owner Name: Harvest Properties Owner Address: PO BOX 110462 ANCHORAGE. AK 99511-0462 Site Address: 016433 COBBLESTONE HILL RD Lot Size: 4342982 SO. FT. Total Bedrooms: 0 Permit Bedrooms: 0 This permit is for the construction of: ❑ Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy ❑Q Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specked In Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. -WHEN THE WELL HAS BEEN COMPLETED AND SATISFACTORY WATER PRODUCTION HAS BEEN DETERMINED, THE WELL DRILLER SHALL PLACE AN APPROVED SANITARY SEAL ON THE WELL HEAD AND NO PITLESS ADAPTER OR PUMP SHALL BE INSTALLED UNTIL AN APPROVED WASTEWATER DISPOSAL SYSTEM HAS BEEN CONSTRUCTED. -THIS PERMIT IS FOR THE PROPOSED VIEWS AT PROMINENCE LOT 55 Received By. Issued By. � Date: 3 it OS Municipality of Anchorage Development Services Department ;''� " •. Building Safety Division /i On -Site Water and Wastewater Program 4700 South Bragaw St P.O. Box 196650 Anchorage, AK 99519.6650 www.cf.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. aso - f o t - 010 Permit Number SW Propertyowner(s) Harvest Prnperties T.T.r Dayphone 522-0514 Mailing address P O Box 111411, Anchorage AK Zip Code 99511 Site ad a• • ••a •u r •� •- ••s• • .•• •� 11 .• s. •r. ta• South Legal description (Section, Township & Range) NE, SW. a NW cruarters of th . SR 1/4 of Sect oh 2, Township 11 North, Range 3, Seward Meridian Lot Size 4;03 3#; 1 Acres/Sq.Ft. Number of Bedrooms n 1a Lot #'ib6S NOt C�PS�� f N3C THIS APPLICATION I�FOR: Sewer Only ❑ Well Only Sewerand Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above Information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. Authorized (Signature of propertV/GG6ner or authorized Permit/Rush Fees: l f�"yu Waiver Fees: Date of Payment 3l 1-4105 Date of Payment Receipt Number. 6(4QI2 Receipt Number. (R/v. 09104 �3 CarNe�- N III � W I I � W � � , Z � O O •� ~ U oa OJ� Jd O co f. J F �3 CarNe�- MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water d Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 995196650 (907) 343-7904 ON-SITE WATER SUPPLY PERMIT Initial Date Issued: Mar 21, 2005 Expiration Date: Mar 21, 2006 Permit Number. SW050053;volf"s-of FRo�-JOA" `r.r'S'L Parcel ID: 020-101-06 Legal Description: Design Engineer: 0070 KND Engineering Site Address: 016433 COBBLESTONE HILL RD Owner Name: Harvest Properties Owner Address: PO BOX 110462 ANCHORAGE, AK 99511-0462 Lot Size: 4342982 SQ. FT. Total Bedrooms: 0 Permit Bedrooms: 0 This permit Is for the construction of: ❑ Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified In Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. -WHEN THE WELL HAS BEEN COMPLETED AND SATISFACTORY WATER PRODUCTION HAS BEEN DETERMINED, THE WELL DRILLER SHALL PLACE AN APPROVED SANITARY SEAL ON THE WELL HEAD AND NO PITILESS ADAPTER OR PUMP SHALL BE INSTALLED UNTIL AN APPROVED WASTEWATER DISPOSAL SYSTEM HAS BEEN CONSTRUCTED. -THIS PERMIT IS FOR THE PROPOSED VIEWS AT PROMINENCE LOT 56 Received By: Issued By. _( N 1 Date: Date: 3 2 t Asunicipality of Anchorage Development Services Department ;''` •a. Building Safety Division =' On -Site Water and Wastewater Program 4700 South Bragaw St P.O. Box 196650 Anchorage, AK 99519.6650 www. ci. anchorage. akus (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. Z 0 ' 101 — 0(0 Permit Number SW Property owner( Haryp4* Drnnr>rtjtP; T.T.r Dayphone 522-0514 Mailing address P O Box 11 1411 , Anchorage AK Zip Code 99511 Site :•• • •f - Legal description (Section, Township & Range) NE Sw a tv*^ au rters of the SF 1/4 of Spe*ioh 2, Township 11 North, Range 3, Seward Meridian Lot Sized Acres/Sq.Ft. Number of Bedrooms n/a Lot s56w�}Carllo_ THIS APPLICATION IS FOR: Sewer Only ❑ Well Only Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above Information Is correct. I further certify that this application is being made for a Single Family Dwelling and is In accordance with applicable Municipal Codes. Authorized (Signature of property/6Aer or authorized Date of Payment Receipt Number. &491 Z Receipt Number. (Rw. 09/04) C C N W P&1�79, yok Go-- p�o�,�k �ntn�eQ O 0 co MUNICIPALITY OF ANCHORAGE Development Services Department Onsite Water 6 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WATER SUPPLY PERMIT Initial Date Issued: Mar 21, 2005 Expiration Date: Mar 21, 2006 Permit Number: SW050052 # ^� �B.K.oP-Qker*iNENof.;rr`Gg Parcel ID: 020-101-06 Legal Description: Design Engineer: 0070 KND Engineering Site Address: 016433 COBBLESTONE HILL RD Owner Name: Harvest Properties Owner Address: PO BOX 110462 ANCHORAGE. AK 99511-0462 Lot Size: 4342982 SO. FT. Total Bedrooms: 0 Permit Bedrooms: 0 This permit is for the construction of: ❑ Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specked in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to Apri115, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. -WHEN THE WELL HAS BEEN COMPLETED AND SATISFACTORY WATER PRODUCTION HAS BEEN DETERMINED, THE WELL DRILLER SHALL PLACE AN APPROVED SANITARY SEAL ON THE WELL HEAD AND NO PITLESS ADAPTER OR PUMP SHALL BE INSTALLED UNTIL AN APPROVED WASTEWATER DISPOSAL SYSTEM HAS BEEN CONSTRUCTED. -THIS PERMIT IS FOR THE PROPOSED VIEWS AT PROMINENCE LOT 68 Received By. Jm' ` Date: Issued By "` Date: 311 ZI A, i Municipality of Anchorage Development Services Department ;''" £l•. Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St P.O. Box 196650 Anchorage, AK 99519-6650 www.cl.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 07-0-101-0(0 Permit Number SW Propertyowner(s) Harvest PrnpPrti(-s T.T.r Dayphone 522-0514 Mailing address P O Box 11 1411 , Anchorage AK Zip Code 99511 #JpM • ••s •« r ••••lard' • • .• 11 .• a. •r.w v �• Site :d UMMI • •�: Legal description (Section, Township & Range) ,NE SW b NW auarters of to SE 114 0 j&tioh 2, T wnship 11 North, Range 3, Seward Meridian Lot Size W.13 # t AcreslSq.Ft. Number of Bedrooms n/a Lot N b8, Sovkd\)s cocneQ. THIS APPLICATION IS FOR: Sewer Only ❑ Well Only Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above Information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. Authorized (Signature of propb* owner or PermitlRush Fees: M-0 U Waiver Fees: Date of Payment 0/1,410.5, Date of Payment Receipt Number. (PL4Q 12 Receipt Number. (Rw. 0904) C L LOW O 0 Municipality of Anchorage Department of Health and Human Services di5r1S Tom Fink, 825 "L" Street Mayor P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 December 2, 1993 Tom Baird Henson, Jr. PO Box 141781 Anchorage, Alaska 99514 1781 Subject: T11N R3W Section 2 N' SE4 & N, SWa SE4 Permit #SW920396, PID #020-101-06 The subject permit, issued November 25, 1992 by this office for a single family well and/or on-site wastewater system, has expired as of November 25, 1993. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. If you have drilled the well, a well log must be sent to this office for documentation of the installation and to close the permit. If a licensed Professional Engineer has inspected the installation of the on-site wastewater system, the original as -built inspection report must be sent to this office for review, approval and documentation. All inspection reports must be submitted within 30 days of construction completion. When applying for a new permit, the fees are: $320.00 for an on-site wastewater permit; $120.00 for a well permit and $440.00 for a combined on-site wastewater and well permit. If you have any questions, please call this office at 343-4744. Sin erely, J n Smit , P. E. ogram anager n -site Services enc: Copy of Permit cc: Arctic Slope Consulting Group MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW920396 DESIGN ENGINEER:ARCTIC SLOPE CONSULTING GROUP OWNER NAME:HENSON TOM BAIRD JR & OWNER ADDRESS:BOX 1411781 ANCHORAGE, AK 99514 PARCEL ID:02010106 LEGAL DESCRIPTION: T11N R3W SEC 2 N2SE4 & N2SW4S E4 LOT SIZE: 999999 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: 4 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: PAGE 1 OF 1 DATE ISSUED:11/25/92 EXPIRATION DATE:11/25/93 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: THE TOTAL DEPTH OF THIS BED SHALL NOT EXCEED 2 FEET BELOW THE NATURAL GROUND LEVEL. RECEIVED ISSUED B' DATE: DATE: e:53 i aATE T9 ENGINEERS • ARCHITECTS • SCIENTISTS • SURVEYORS November 13, 1992 Mr. Dan Roth Municipality of Anchorage Dept. of Health and Human Services 825 L Street Anchorage, Alaska 99501 Re: Septic System Approval Lot 3, T1 IN R3W S2 Dear Mr. Roth: Attached is the permit application for upgrading a septic system on the above referenced lot. Below is a narrative of probable impacts to adjacent properties. 1. Adjacent Wells - There are no existing wells within 200 feet of the proposed new septic system. The proposed absorption field does not adversely impact other wells. 2. Adjacent Wastewater System - No systems exist within 200 feet of the proposed system. 3. Reserved Space - Adequate space remains within a 30 foot radius of the test holes immediately to the south of the proposed system. The reserve space can accommodate a bed 50 feet long and 24 feet wide. 4. Drainage - The proposed system is on a wide ridge, and drainage is towards the northeast, northwest, and southwest. No concentrated surface water will be directed toward the field and no existing streams are within 100 feet of the proposed field. The installation of this on-site system will have no probable impacts to adjacent well or septic systems. Sincerely, Carey S eY er Sr. Civil Engineer EG: CSM: CC:1110\0026\046 Attachment 1 =' 3 s s: rf ns ec,na nao7}Iye/ o eosoa.,m,a n 121 Car y .Meyer 353 p RE)F'ES510 , MP3 301 ARCTIC SLOPE AVENUE, SUITE 200 • ANCHORAGE, ALASKA 99518-3035 (907) 349-5148 • FAX (907) 349-4213 Permit No. 1 of 2 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 Anchorage, Alaska 99519-6650 Telephone:343-4744 On—Site Wastewater Disposal System and/or Well Inspection Report Legal Description LOT 3 T11 N R3W S2 UNDEVELOPED AREA WEST PROPERTY LINE @ 1100 FT SITE MAP T'=1001 • ►. NOTE: A WELL PERMIT MUST BE OBTAINED FROM THE DHHS PRIOR TO THE DRILLING OF A WELL ON THIS LOT. EASTERN PROPKRTY LINE > 1000 F PROPOSED WELL OW BMA END OF LINE POWER POLE ELEV=1000 BM B - TH 1 30 FT SOUTH 10F1 EAST OF POWER POLE TH 2 79 FT SOUTH 0 FT EAST OF POWER POLE TH 3 1109 FT SOUTH 1OFT EAST OF POWER POLE Permit No. Page 2 of 2 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 Anchorage, Alaska 99519-6650 Telephone: 343-4744 On—Site Wastewater Disposal System and/or Well Inspection Report Legal Description LOT 3 T1 1 N R3W S2 PID No: GHOULS NONN GWO NBE 0' O O aFP .. 1250 GALLON SEPTIC TANK MONRORING TUBE 24.0' W. RESERVE SPACE GIFINWI SEPTIC SYSTEM PLAN VIEW DESCRIPTION BMA END OF LINE POWER POLE LEV=1000) BM B — 2" INSULATION ONITORING CLEANOUTS UNDER 24" TUBE BACKFILL 2: SLOPE = 2% EXISTIN 14" GROUND NOTES 1. CONTRACTOR TO VERIFY MIN. SO. FOOTAGE 12-- , PRIOR TO PLACING TOPSOIL. 2. CAUTION SHALL BE TAKEN TO MINIMIZE REMOVAL OF EXISTING VEGETATION OUTSIDE 24. OF SEPTIC AREAS. 9 3. DISTURBED AREA SHALL BE SEEDED TO PREVENT EROSION. 7 4. NO WELLS. SURFACE WATER, OR CURTAIN DRAINS WITHIN 100 FT OF NEW ABSORPTION SYSTEM. BEDROCK ABSORPTION SYSTEM CROSS SECTION "=6' 2• INSULATION UNDER 24" OF FlLL 2" INSULATION 2. UNDER 24" OF FILL 2' INSULATION UNDER 24" OF FILL AA v/r /// �C'••'• // 1 -2' �.•' 9 =�. : 49th GRO.VN2$UREACL ..... ... ... ............ 10" ]IT j ... ... ... .... �'. Car S. Mey ,2j G1 •• E 6353 �� FOUNDATIONzo• CLEANOUT o• T G ABSORPTION SYSTEM PROFILE /'lilt% FESS IONP -`1 HORIZ 1"=20' VERTICAL 1"=6' ��%%\\ ASCG Calculations System Calculations for Lot 3 30 -OCT -92 Page 1 of 1 Tank Size 4 Bedrooms = 1250 Gallons Absorption Field Sizing Using an acceptance rate of 0.5 gal/SF/day and a daily load for 4 bedrooms of 600 gal/day. Req'd Absorption Area = 600 gpd / 0.5 gpd per SF = 1200 SF System Dimensions 50.0'X 24.0' = 1200.0 SF The laterals are to be spaced 6.0' apart and 3.0' from edge of the bed. o GniF° 5x ao e:aaaao oa oo aoo°oo�<° 2 Care .Meyer ©rROFESS\��� ASCG [wict INCORPORATED amrwrs w. .ernc xas nw.. sort mo • u�aawx, wsu sn�e-wu SOILS LOG - PERCOLATION TEST PERFORMED FOR: TOM HINSON LEGAL DESCRIPTION: LOT 3 TWSHP> RNG, SCTN DATE PERFORMED: THIN RAV S2 160CM 0— 1 '1— 3- 4- DEPTH (FEET9 TEST HOLE 1 DESCRIPTION BM AND OF LINE POWER POLE (ELEV=1000) TOPSO B - LBM 0 min SAND GRAVEL TH 1 130 FT SOUTH 1OFT EAST OF POWER POLE TH 2 /9 FT SOUTH 0 FT EAST OF POWER POLE TH 3 109 FT SOUTH 10FT EAST OF POWER POLE SILTY SAND m 5- 6 - SILTY 7- SAND GRAV 8- - F lo- 11- 13- 14- 15- 16- 17- 18- 19- 20- PERC TEST' OF 49th i...: ...... . ....... ... i A • Co y S. Meye 1 mCi '. E 6353 / G _ /I' �II... ,pROFFSS 0' ;\?� SITE PLAN UNDEVELOPED AREA DATE 4' NET TIME DEPTH TO WATER EASTERN PR ERTY LINE 11000 00 FT 0 min 4'-0. 0" PROPOSED 2 WELL 0 10 rein 4'-1.7" 1.7" m A O a 20 rein m 1.6" GROUNDWAS WATER ■■■■■■■■ - HOLE ENCOUNTERED? N • • • ■■■■■.■■DEPTH TO WATER AFTERMONITORING? DATE: If -l -W2 NO. DATE GROSS TIME NET TIME DEPTH TO WATER NET DROP 1 160CT92 14:25 0 min 4'-0. 0" - 2 14:35 10 rein 4'-1.7" 1.7" 3 14:45 20 rein 4'-1.6" 1.6" 4 14:55 30 rein 4'-1.4" 1.4" 5 15105 40 min 4'-1.4" 1.4" 6 15:15 50 min 4'-1.4" 1.4" 7 - - - - 8 - - - - 9 - - - - 10 - - - - PERCOLATION RATE 71 041N/INCH) PERC HOLE DIAMETER 6.0° TEST RUN BETWEEN 44.0" FT AND 4-0.0" IT COMMENTS: PERC HOLES WERE PRE-SOAKED FOR FOUR HOURS PRIOR TO TESTING PERFORMED BY: ERIC GROPP / GREG MAGEE CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT' ON THIS DATE: 160CM ASCG un INCORPORATED SOILS LOG - PERCOLATION TEST PERFORMED FOR! TOM HINSON LEGAL DESCRIPTION LOT 3 TWSHP, RNG, SCTN DATE PERFORMED: TIN R3W S2 160C M 0- 1_ 2- 3_ DEPTH (FEET) TEST HOLE 2 DESCRIPTION OMA ROOF LINE POWER POLE (ELFV=1000) TOPSOI OM 0 - 00 FT 2'-6.0" - TH 1 30 FT SOUTH 1OFT EAST OF POWER POLE SILTY TH 2 79 FT SOUTH 0 FT EAST OF POWER POLE TH 3 709 FT SOUTH 10FT EAST OF POWER POLE PERC TEST SAND 4- 5- 6- SILTY SAND 7- G RAV 8- fn 16- 17- 18- 19- 20- SLOPE q OF q�ghlh �P•.•• •. S�rq� 9th i ....... S ?T : Carey S Meyerr $ me •, CE 353 S /r �Sr •, •.' Gam? ilifqFit PR ' •........• P� 6YM_Y_:i'.[�lll UNDEVELOPED AREA DATE 4 NET TIME DEPTH TO NET WATER DROP EASTERN PR ERTY LINE > 1000 00 FT 2'-6.0" - 2 PROPOSED 14;40 WELL 0 N O 3 14:50 i m 2'-7.4" 1.4" z z v 0 28 min a 5 ONE M IM •.E 01. s no IlArp. N I M •■■■■■■■■ MMM M NO. DATE GROSS TIME NET TIME DEPTH TO NET WATER DROP 1 16OCT92 14:30 0 win 2'-6.0" - 2 14;40 10 min 2'-7.6" 1,6" 3 14:50 20 Min 2'-7.4" 1.4" 4 14:58 28 min 2'-6.9" 0.9" 5 15:08 38 rein 2'-7.3" 1.3" 6 15:18 48 min 2'-7.3" 1.3" 7 - - - - 8 - - - - 9 - - - - 10 - - - - PERCOLATION RATE 7.7 QN ANCH) PERC HOLE DIAMETER 6.0° TEST RUN BETWEEN 2'-6.0" FT AND 3'-0.0' ITT COMMENTS: PERC HOLES WERE PRE-SOAKED FOR FOUR HOURS PRIOR TO TESTING PERFORMED BY ERIC GROPP / GREG MAGEE CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE 160CM SOILS LOG — PERCOLATION TEST of A4,1'a,, ASCD TOM HINSON PERFORMED FOR: ^�' MI /ACM AW° [ I.K. SVR ]W . YGpNfL NAVA 9i51t_SA 49th LEGAL DESCRUMONLOT 3 16353 eyerS. M TAE_11S2 DTPERFO D 0CT .•• �S�`"_ S 'i DEPTH (FEET) o- TOPSO 1- 2- 3- SILTY SAND Iva 18- 0- 20 - TEST HOLE 3 DESCRIPTION BMA END OF LINE POWER POLE (ELEV=1000 BM B — TH 1 30 Ff SOUTH 1OFT EAST OF POWER POLE �TyH �2 79 FT SOUTH 0 FT EAST OF POWER POLE \ 109 FISOUTH LOFT EAST OF POWER POLE FtKu TEST HOLE BOTTOM / 7�h�j6n�<ece, ux� SLOPE WAS GROUND WATER ENCOUNTERED? N IF YES, AT WHAT DEPTH? - DEPTH TO WATER AFTER MONITORING? - DATE: - SITE PLAN UNDEVELOPED AREA DATE 4 NET TIME DEPTH TO WATER EASTERN PR ERTY LINE > 1000 00 FT 0 min PROPOSED - WELL 0 14:43 y_ rain 1'-8.6" 2.6" A M 0 20 M 1'-8.2" NO. DATE GROSS TIME NET TIME DEPTH TO WATER NET DROP 1 160CT92 14133 0 min 1'-6.0" - 2 14:43 10 rain 1'-8.6" 2.6" 3 14:53 20 min 1'-8.2" 2.2" 4 15:03 30 rein 1'-8.2" 2.2" 5 15113 40 min 1 '-8 . 0" 2. 0" 6 15:23 50 rein 1'-8.0" 2.0" 7 - - - - 8 - - - - 10 - - - - PERCOLATION RATE 5.0 (MINANCH) PERC HOLE DIAMETER 6.0" TEST RUN BETWEEN 1'-6.0" FT AND 7-0.0" FT COMMENTS: PERC HOLES WERE PRE-SOAKED FOR FOUR HOURS PRIOR TO TESTING PERFORMED BYERIC GROPP / GREG MAGEE CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 160CM ENGINEERS • ARCHITECTS • SCIENTISTS • SURVEYORS November 9, 1992 Municipality of Anchorage Dept. of Health and Human Services 825 L Street Anchorage, Alaska 99501 Re: Septic System Design Lot 3, T11N, R3W, S2 Dear Sirs: RECEIVED NOV 2 41992 Municipality of Anchorage Dept. Health & Human ServlceS A concern was expressed about the reserve space in the septic system design for Lot 3, T1 IN, R3W, S2. Most of the reserve space on the submitted design is within a 30 foot radius of testhole /i3, in which bedrock was encountered at a depth of 4 feet. The relatively shallow depth to bedrock could cause the cost of constructing an absorption field upgrade using the reserve space to be prohibitive. However, based on our surface and subsurface investigation of the site and the considerable size of the lot, we are certain that many potential sites for a sewer upgrade exist on the lot. Gently sloping ground (< 10% slope) is available for more than 100 feet to the East, West, and South of the proposed system. truly yours, r� i Carey S` eyer, E. Sr. Civil ngineer CS M: EG :MLT:1110-0026.046 301 ARCTIC SLOPE AVENUE, SUITE 200 • ANCHORAGE, ALASKA 99518-3035 (907) 349-5148 • FAX (907( 349-4213 Municipality of Anchorage Department of Health and Human Services 825 " L' Street Rick Mystrom, P.O. Box 196650 Anchorage, Alaska 99519-6650 Mayor 343-4744 November 15, 1994 Mr. Tom Henson P.O. Box 141781 Anchorage, AK 99514 Subject: T11N, R3W, See. 2, N2SE4 & N2SW4SE4 Permit#SW930355, Parcel ID #020-101-06 Dear Mr. Henson: A The subject permit, issued September 10, 1993 by this office for a single family well and/or on- site wastewater system, has expired as of September 10, 1994. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. If you have drilled the well, a well log must be sent to this office for documentation of the installation and to close the permit. If the on-site wastewater system has been completed and a licensed Professional Engineer has inspected the installation of the on-site wastewater system, the original as -built inspection report must be sent to this office for review, approval and documentation. All inspection reports must be submitted within 30 days of construction completion. When applying for a new permit, the fees are: $320.00 for an on-site wastewater permit; $120.00 for a well permit and $440.00 for a combined on-site wastewater and well permit. If you have any questions, please call this office at 343-4744. 'co James Cross, P.E. Program Manager On -Site Services JC/kb cc: Carey Meyer, P.E. PAGE 1 OF MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL SYSTEM PERMIT PERMIT NUMBER:SW930355 DATE ISSUED: 9/10/93 DESIGN ENGINEER:DUMMY COMPANY EXPIRATION DATE: 9/10/94 OWNER NAME:HENSON TOM BAIRD JR & OWNER ADDRESS:P.O. BOX 141781 ANCHORAGE, AK 99514 PARCEL ID:02010106 LEGAL DESCRIPTION: T11N R3W SEC 2 N2SE4 & N2SW4S E4 LOT SIZE: 999999 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: 4 THIS PERMIT IS FOR THE CONTRUCTION OF: WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 OR 343-4681 AFTER BUSINESS HOURS 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL P RECEIVED ISSUED BY ROVISION c � Y: moi= DATE:/ L} G / / DATE : llzz:� j / ,lam (�, Ism 1 'Termii,t No. 1 of 2 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 Anchorage, Alaska 99519-6650 Telephone:343-4744 On—Site Wastewater Disposal System and/or Well Inspection Report Legal Description LOT 3 T1 1 N R3W S2 PID No: NOTE: A WELL PERMIT MUST BE OBTAINED FROM THE DHHS PRIOR TO THE DRILLING OF A WELL ON THIS LOT. UNDEVELOPED AREA 4 ' EASTERN PRO RTY WEST PROPERTY LINE > 1000 F LINE @ 1100 FT PROPOSED RESERVE WELL Ow SPACE r0 T 3 OPOSEU z0 H USE me v F`1 ,z o� C) 00 -71 0 —i m qE OF g11h1 BM A END OF LINE POWER POLE (ELEV=1000) S 49th . ......... .Y .......ii BM B TH 1 30 FT SOUTH 10FT EAST OF POWER POLE ; '. Car S. Mee TH 2 79 Fi SOUTH 0 FT EAST OF POWER POLE / —6353 TH 3 109 FT S/OUTH 10FT EAST Or POWER POLE // �Sl SITE MAP /I,I ��It PROFESS `���`