Loading...
HomeMy WebLinkAboutT12N R4W SEC 10 LT 12 W2 Municipality of Anchorage On-Site Water and Wastewater Program • (907) 343-7904 Page of ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181145 PID Number: 011-161-29 Dwelling: ❑ Single Family (SF) ® Duplex (D) El Multiple (SF and/or D) Project: ❑ New ® Upgrade Name: BYRON BIRDSALL REV. TRUST ABSORPTION FIELD - EXISTING Address ❑ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound 8437 JADE STREET, ANCHORAGE, AK 99502 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 4 -- GPD/SF -- Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot -- Ft. -- Ft. 12 W2 Fill added above original grade Gravel length Township Range Section -- Ft. -- Ft. 12N 4W 10 Gravel width Beds: Number of Lines Distance between lines SEPARATION DISTANCES -- Ft. Ft. To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist.between trenches From Tank Field Tank Line -- Ft2 -- Ft. Well 100'+ -- -- __ 25'+ TANK ® Septic ❑ S.T.E.P. 0 Holding 0 Other Manufacturer Capacity Surface Water 100'+ -- __ __ ANCHORAGE TANK 1500 Gal. Material Number of compartments Lot Line 5'+ __ __ __ STEEL 2 NA Foundation 10'+ -- -- -- LIFT STATION Manufacturer Capacity Curtain Drain NA -- NA -- Gal. Remarks Pump on level at Pump off level at High water alarm at Existing septic tanks decommissioned per code. New tank installed & connected in. in. in. to system. Deep-Burial 10-gauge Tank. Pump make and model Electrical Inspections performed by PIPE MATERIAL House to tank D3034 Tank to D3034 Installer ArcticTerra drainfield Drainfield -- CO/MT D3034 Inspector ARCTERRA BENCH MARK (Assumed elevation) 100 ft Inspectio 'S'7/16/2018 2nd 9/19/2018 Location and description da 3rd 4th Garage Slab COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL 40,14b:41 \ \ AirAir OF i,ip 4 II Conditional Approval: Date / om. .4 1'*`'4- Tom* >' t A� :// KFNNF:"}i x OL ,{5 / A CF. 7;1 �,v Air i k,"Ror sstor ...► Approved J Date( 2 -57-10 "kNib.n6'40.44 Inspection Report ST copy 3.doc AS-BUILT SYSTEM DETAILS/SITE PLAN Permit ❑SP181145 W1/2 L❑T12 T12N R4W SEC10 S.M. ALASKA PID# 011-161-29 I S89'57'00"W 132.49' 0 33' R.O.W. ESMT LOT 1 a - wn MT ek/SnNc FiFCp C: CO "n Z 2O cn COs - O CO ö O Div NEW 1500-GAL CO O w WEST 22 C �CO SEPTIC TANK O LOT 12 LOT 2 - o Id 'T' � tii m In U) - H 0 I til A til FCO H BM 44.0' 8 46.2' ' PAVED b D/W N EXISTING ) SCALE: 1' = 410' i 4-BR Lon,,_ (o 088.20 87.61 '- A—C=65,6' A—C=65,6' o B—C=62,5' o A—D=75.4' o dP FINAL GRADE f _ B—D=72,2' ce 1 VARIES 91 --`1500 GAL o SEPTIC a TANK EXISTING FIELD 81.35 81.18 _ I _ b'-‘46:1‘, � lN\ I I SCALE: NTS /C��� 1�4 PREPARED FOR: RCTER `� BYRON BIRDSALL REV. TRUST )A,'''' 1 8437 JADE STREET ;'3 ��AlAtt. 1 `� * :49 TH i� ANCHORAGE, AK 99502 �,�� i.'1„\ mac. / . �►4o.GI� , . . / 1/E� II11I11 KENNETH ; S HELD BOOKS COMPUTED: % CE-711; �{ce / BOUNDARY:N /A DRAW BMW `1�� A�` 1J \ 1 . 45 STAKING: ! CHECKED: .- $) \ "VW/ 2 �' 1A4k9FESSIO1Ay ASBUILT: SLS DATE 9/24/18 4.. / O'Oo/ __� D . FILE: GRID: 2324 (F 0'04, �C e ` ACRD FILE: FILE No.: R/frFq S ULT.I NG •X*6 L. FILE 18163 AK. 99577 7'/16/1& wz_xvk. • °""r� MUNICIPALITY OF ANCHORAGE vo n r On-Site Water&Wastewater Program •�, H• r-�,dl PO Box 196650 4700 Elmore Road ` i l Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 1)",r.: http://www.muni.org/onsite J 1)cpirtnicnt 4NCHOP"VE On-Site Wastewater Disposal System Permit Permit Number: OSP181145 Effective Date: 7/11/2018 Work Type: SepticTank Upgrade Expiration Date: 7/11/2019 Tax Code Number: 01116129000 Site Legal Address: T12N R4W SEC 10 LT 12 W2 G:2324 Site Mailing Address: 8437 JADE ST, Anchorage Owner: BIRDSALL BYRON REVOCABLE TRUST Lot Size in Sq Ft: 39384 Design Engineer: ARC TERRA CONSULTING INC Total Bedrooms: 4 This permit is for the construction of: ❑ Disposal Field Septic Tank ❑ Holding Tank 0 Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72)and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing 7 /3 /* Received By: Date: ►7 c Issued By: _. QQJLCU Date: I I o MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On-Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 011-161-29 Property owner(s) BYRON BIRDSALL REV. TRUST.... Day phone 907-227-6794 Mailing address 8437 JADE STREET, ANCHORAGE, AK 99502 Site address 8437 JADE STREET, ANCHORAGE, AK 99502 Legal description (Sub'd., Block & Lot) T12N R4W SEC 10 LOT 12 W2 Legal description (Township, Range & Section) Lot Size 39,384 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) (w/wo ADU) Septic Tank Upgrade Duplex (D) Holding Tank Renewal ❑ Multiple Dwellings Privy n (SF and/or D) Private Well Water Storage THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Sign. • ey •roperty owner or authorized agent) Permit/Rush Fees: oZ 6 Waiver Fees: Date of Payment: io/i2/L3 Date of Payment: Receipt Number: asp'TO Receipt Number: Permit No. o S P 181145- Waiver No. Permit App_9-1-12.doc �RCTERR-I ,, 34,` ARCTERRA • CONSULTING, INC _., e 212 E. 51st Ave,Anchorage,AK.99503 `* , Office(907)868-3791,Fax(907)868-3793 f'9,aTh t I NG•`6 F•'A,„5”--. June 16, 2018 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Septic Tank Upgrade Permit—T12N R4W SEC 10 W2 LOT 12 The owner has requested we proceed forward to obtain a septic permit to upgrade the failed septic tank on the subject lot. The proposed upgrade will serve the existing 4-bedroom duplex. Attached are the ADEC record documents of the existing septic system to augment the MOA file. The area is served by private and public water as noted on the design. There is no surface water within 100' of the proposed tank. We do not expect there to be any adverse effect on adjacent lots by the development of this tank. If you have any questions, please contact me at 868-3792/FAX 868-3793. Respectfully submitted, ArcTerra Consulting, Inc. A litwArr Kenneth M. Duf i , .E. Attachments: On-Site Sewer Application Wastewater Absorption System Details/Site Plan ADEC Record Documents 20441 PTARMIGAN BLVD • EAGLE RIVER,AK 99577-8736 • PH(907)868-3791 • FAX(907)868-3793 WASTEWATER DISPOSAL SYSTEM DETAILS T12N R4W SEC10 W1/2 LOT 12 N89'55'00"W 165.50' w WEST 84th AVE w 33' 33' ESMT PLOTTED FROM MOA GRID MAP 1...;46.%4 MO S 4 D c,, �� � c,, m I.C1 1 VI C_ ti > v ED o 4X/Sr m I 0 /.V NO PUBLIC WELLS WITHIN 200' OF (n 0 M'1' Tnrkc �' ----------------- PROPOSED SYSTEM. —I M y Cn hO'� NO PRIVATE WELLS WITHIN 200' OF )0 O 1" PROPOSED SYSTEM EXCEPT AS NOTED. cn q rn 3 N --I o Z S.T• 3 a " Df.Co'1k1. a L 0 1 2 0 I Z 4 !a s pivt. zo W 'v WEST 1/2 12 New o o !50V-(P.41. o � �� N ac.I, 00 w o. N A P.T. Cvt. I DECOMMISSI❑N EXSITNG TANKS L. — cd 4, ,PER CODE & INSTALL NEW 42.4 44 X__-x— o 4500-GAL SEPT❑IC TANK 10'+ 2q N s � r� FROM FOUNDATION, 5'+ FROM "— EXISTING "4 u ASPHALT DRIVE $0 HOUSE N j0 LOT 3 (tXISTING SEPTIC FIELD, & 100'+ r3.g , FROM PRIVATE WELLS. :o ox_ INSULATE TANK IF <4' OF COVER. •N jrsi k o. CONTRACTOR WILL ENSURE 4 _0.1 22..7 �'"� X .,MINIMUM 2Z SLOPE INT❑ TANK. ` BRAVE , bRIVE „ 3. CONTRACTOR WILL ENSURE ALL l 17.4 ---).x ax oSEPARATIONS TO ADJACENT WELLS, 'c`y-XIX_; 20.2 ,SEPTICS, EASMENTS, PROPERTY EXISTING cA o = • LINES, ETC.. BUILDING w `� 11.3 LOT 4 a, 0 20.2 -- x T Scale: 1'= 50' N _ 67 PAGE 1 OF 1 33 x 6, I .X M K M • N N Y X o S89'55'00"C 165.54' ~1,4 _` OF ALS I / �� <Q,S 4 PREPARED FOR: gCTER� '�� + , BYRON BIRDSALL REV. TRUST E / 62* 4 • TH%\ * , 8437 JADE STREET oti /11)It, rs�. o` ANCHORAGE, AK 99502 > �,�� .'1„\ �. / I o / • KE.111111i4091.D / FIELD BOOKS COMPu�D: D 111113•11111111 BOUNDARY: DRAYM: BMW �r CE— 0• ww / N/A ��fir►R,. 0 1 � • STAKING: CHECKED: KMS . `/ 1 . G�s�� ~� N/A �P \!'t�.1I �M a ll� AsauILT: KLD DATE 6/15/18 .....�9"' '�,// �6�/ S$I� DWG. FILE: GRID: SWZ83F) G, co�' 14,. cci, \`\� ACRD FILE' FILE roe No.: 18163 /SFR s sss�'��6 WALTER J. HICKEL, GOVERNOR DEPT. OF ENVIRONMENTAL CONSERVATION R EC E IVE D ANCHORAGE DISTRICT OFFICE 800 E. Dimond Blvd., Suite 3-470 ANCHORAGE, ALASKA 99515 MAR 2 199;~ 349-7755 Munic~pahty of Anchorage Dept. Health & Human Services Februaw 26,1993 Mr. Tobben Spurkland, P.E. 203 West 15th. Avenue, Suite 206 Anchorage, Alaska 99501 Subject: Wl/2, Lot 12, Section 10, T. 12 N., R.4 W., S.M., Anchorage, Alaska, Class C Public Water System, Wastewater Disposal System, and Waiver Request, ADEC Project Numbers 9321-DW-052, 9321-DWW-037, and 9321-WV-017; Review Dear Mr. Spurkland: This letter is in response to your submittals, received in this office on January 27, and February 3, 1993, in which you requested approval for the omsite Clas~ C Public Water System and Wastewater Disposal System. In addition, you requested that the Department waive the separation distance from the existing Class C Public Water System Source Well and the septic tank located on Lot 17 from the minimum of 150 feet to the exiting 140 feet. I have reviewed the submitted information and this office's files on the above- referenced project. Based on this review, I have the following comments. WASTEVVATER DISPOSAL SYSTEM From the information submitted and found in the files, it appears that the wastewater disposal system was installed substantiaiiy in accordance with State regulations and guidelines at the time. The results of the adequacy test conducted on December 16, 1992 also verify that on the day the adequacy test was performed the wastewater disposal system was accepting the necessary flows. Therefore, the wastewater disposal system is approved for the concerns of this Department. The enclosed signed Approval of On-Site Residential Water and Sewer Systems, constituting this approval, is enclosed for the existing wastewater disposal system. DRINKING WATER SUPPLY SYSTEM The existing Cfass C Public Water System was approved by this Department on July 30, 1987. The results of the total coliform bacteria and nitrate (as nitrogen) was below the Tobber Spurkland 2 February 26, 1993 maximum contaminant concentration levels found in 18 AAC 80.070. As a result, this public water system is in compliance with the provisions of 18 AAC 80 State of Alaska Drinking Water Regulati0n~. The noted Approval of On-Site Residential Water and Sewer Systems also constitutes approval of the Class C Public Water System. WAIVER From the submitted information, it appears that the existing lesser separation distance does not effect public health and your client has no objection to the separation distance. Therefore, in accordance with the provisions of 18 AAC 72.015, Wastewater Disposal Regulations, and 18 AAC 80.030, Drinking Water Regulations, the requested waiver is being granted. The separation distance between the Class C Public Water System Source Well on Lot 12 and the septic tank on Lot 17 has been waived from the minimum distance of 150 feet to the existing 140 feet. If the demand on the existing Public Water System changes in any way, this waiver will become invalid. The Department is assigning Public Water System Identification (PWSlD) Number to all public water systems in the State. As a result, the PWSlD Number assigned to this Class C Public Water System is 218043. At this time the State Drinking Water Regulations do not require monitoring for Class C Public Water Systems nor do the conditions in which the waiver was granted require monitoring. However, if the State Drinking Water Regulations do change, to ensure that the information gets to the correct person, please fill in the highlighted areas on the attached form entitled "INVENTORY UPDATE FORM" and return it to this office as soon as possible. Thank you for your cooperation with this Department. If you have any questions, please do not hesitate to call. Sincerely, Keven K Kleweno, P.E. Environmental Engineer KKK/cf Enclosures: As Stated cc: John Smith, DHHS, w/o Enc. CONSULTING ENGINEER 203 W. 15th AVE "C" SUITE 203 ANCHORAGE, ALASKA 99501 TELEPHONE: (907) 279-3916 'JArl MUNICIPALITY OF ANCHORAGE - DECEM._~R 28, 1~ DIVISION OF ENVIRONMENTAL HEALTH DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 620 L STREET ANCHORAGE, ALASKA 9950 Subject: Septic System on W1/2 Lot 12, Sec 10, T12N, R4W, S.M. Gentlemen~ This system was installed in 1983, but has never been approved. An ASBUILT was submitted in March, 1984, but this ASBUILT was not in conformance with the permit issued in 1983. The total absorption area was less then that required by the permit. The native soil is a very clean and coarse gravel with a percolation rate higher than one inch per minute. To system was tested on December 27, 1984. On inspection the tank was found full and the sump to the drainfield dry. One hundred gallons was added to the sump, The water level in the tank did not rise, the water level in the sump rose immediately to 36 inches and stayed at that level. Within 2 hours the sump was again dry, indicating that the system could absorb substantially more than the required 450 gallons per day. Tobb P.O. BOX 6650 ANCHORAGE, ALASKA 99502-0650 (907) 264-4111 TONY KNOWI ES. MA YOR DEPARTMENT OF HEALTH & HUMAN SERVICES May 9, 1985 Mr. Tobben Spurkland, PE 203 West 15th Avenue Anchorage, Alaska 99501 RE: W~ BLM Lot 12, Sec. 10, Ti2N, R4W Dear Mr. Spurkland: I have reviewed your request about the on-site septic system on the above property. The requirement as to size stated in Mr. Robinson's letter of March 20, 1985 will not be waived. Sincerely yours, Rodman Wilson, M.D. Deputy Director for Health Department of Health and Human Services cc: Robert W. Robinson, Manager, Environmental Health Division POUCH 6-650 ANCHORAGE, ALASKA 99502-0650 (907) 264-4111 TONY KNOWLES, MA YOR DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION March 20, 1985 Tobben Spurkland, P.E. 203 W. 15th Avenue "C" Suite 203 Anchorage, Alaska 99501 Reference: W 1/2 BLM Lot 12, Section 10, T12N R4W Dear Mr. Spurkland: Thank you for your reply letter of March 14, 1985 regarding the issue of system adequacy versus system size° Paragraph IIo3 of the Health Authority Approval (HAA) guidelines addresses situations where records are not available for a system° It would be very costly in these situations to investigate the physical size and construction of a system through soil borings and excavations, and our Department does not routinely require this° However, we do require that the depth of field be determined in relation to the maximum seasonal high water table, which does require several soil borings and excavations. This is the least that we will require in order to "certify" a system where records are not available for that system. Where as-built records exist for a system, we have always required that the minimum system size be present, based on the number of bedrooms, in addition to passing an adequacy test. This was explained to you in my last letter. Your request cannot he approved. The system must be enlarged in order to obtain our approval and certification. Sincerely, Robert ~¢, D~v~s&oQ Hanager Env&~onmenta~ Hea~th RR1/ra/d8 . CONSULT!NG ENGINEER 203 W. 15th AVE "C" SUITE 203 ANCHORAGE, ALASKA 99501 TELEPHONE: (907) 279-3916 ROBERT W. ROBINSON MANAGER ENVIRONMENTAL HEALTH DIVISION DEPARTMENT OF HEALTH AND HUMAN SERVICES MUNICIPALITY OF ANCHORAGE POUCH 6-650 ANCHORAGE, ALASKA 99502-0650 Subject: W 1/2 BLM Lot, ~2 SEC. Dear Mr. Robinson: MARCH 14, 1985 ~AUNIClPAUTY OF ANCHORAGB DEPT. OF HEALTH & ENVIRONMI~NTAL PROTECT10~ MAR 8 1985 10~ T12N; R4W .... RECEIVED I have received your letter of March 4, 1985. which does not state the specific reason this system can not be approved. You call the system sub standard, talk about margin of safety without stating what this margin of safety should be,both at the time of construction and during the life of the system. I do not have to tell you that nowhere in the procedures and guide lines developed by your department is this subject discussed. The only criteria for adequacy is that the system can absorb 150 gallons of water per bedroom per day. Paragraph II.3. of the guide lines sta%es that "an adequacy test will also be required if an As Built is not available and the system must be verified". What is to be verified is not clear, but one can assume that what the Department is interested in is the absorption rate of the system, not the physical size. This system, which according to your letter, is more than three and one half year old, is absorbing more than three times ~ the required minimum. It is difficult to understand how you can call that a sub-standard system. I am again requesting apProval of this system. Yours_ Tob~E POL~, ~ '6-660 ANCHORAGE, ALASKA 99502-0650 (907) 264-4111 TONYKNOWLES. MAYOR DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION March 4, 1985 Mro Tobben Spurkland, PE 203 W. 15th Avenue, Suite 203 Anchorage, Alaska 99501 RE: Substandard On-Site Sewer System, W/2 BLM Lot 10, T12N-R4W, SeM. Dear Mro Spurkland: This will have reference to your letter dated December 28, 1984 pertaining to the wastewater disposal system serving a three bedroom single family residence on the lot described as the west 1/2 of BLM Lot 12, Section 10-Ti2N-R4W, Seward Meridian° In a meeting in my office on Friday afternoon, March 1, 1985, you requested that this Department approve the on-site wastewater disposal system based on the results of an adequacy test taken on December 27, 1984 regardless of the fact that the system contains less than one-half of the required absorp- tion area° Commencing in 1979, with the issuance of the initial "Well and On-Site Sewer Permit" (No. 790557 dated 9/20/79) and continuing through March 9, 1984, there have been numerous inconsistencies and infractions by the installer and inspecting engineer involved in this on-site well and sewer installation° A chronological summary of the events and actions relative to the on-site well and sewer is as follows: On 9/13/79, a soil test was taken by Earl Re Barnard (PE) which indicated that a GW (85 sq ft/bedroom) soil strata was observed at a subsurface depth of i' to 15'o The total depth of the test hole was not specifically iden- tified, however, for design purposes, it was assumed to be at 16'o (On one copy of the soil test log, it was indicated in ink that the total depth was 19' o) o On 9/20/79, a "Well and On-Site Sewer Permit" (No. 790557) was issued to Frits Meyer for a three bedroom single family residence in the subject leto The design requirements of this permit specified that a 12' deep trench 26' in length with 5' of gravel should be installed. This specific design would provide the required 255 square feet of absorption area° Mr. ~obben Spurklaed, PE March 4, 1985 Page 2 3. On 12/31/79, a letter was sent to Frits Meyer advising that the Well and On-Site Sewer Permit Noo 790557 had expired because this office had received no information which would indicate that the on-site system had' been installed° This letter also advised that (1) "if you have drilled that well, a well log should be sent to this Department to document the installa- tion date", and (2) "if an engineer has inspected the installation of the on-site sewer system, please have them submit as-builts for our files." There was no response to this letter° 4. On 9/30/81, a "Well Permit" (No° 810259) was issued to Frtts Meyer for the subject loto 5° On 1/4/82, a letter was sent to Frits Meyer advising that the Well Permit NOo 810259 had expired because this office had received no information which would indicate that the well had been completed° This letter also advised that "if you have drilled the well~ a well log should be sent to this department to document the installation date°" There was no response to this letter° 6. On 3/9/84, an "On-Site Sewer Permit (Noo 840036) was issued to Frits Meyer for an upgrade to an on-site sewer system that was apparentl.~ installed in October, 1979 having less than one-half of the required absorption area° This situation was brought to our attention when we received an as-built drawing by Earl Barnard, PE, dated 3/8/84° This as-built and copies of the "Inspector's Daily Report" dated 10/4/79 were prepared and signed by Earl Barnard, PE0 According to the information contained in the as-built drawing and the inspectors daily reports, the sewer system which was installed approximately, 31/2 years earlier, contained only 108 square feet of absorption area %~ereas the required area sho~n on the permit was 255 square feet° 7° On 1/7/85, the office received a copy of a well log prepared by T&T Drilling indicating that a well had been completed on the subject lot on 5/8/81 (approximately 31/2 years earlier) to a total depth of 265' with a completion potential of 5 gallons/minute° 8. On 1/8/85, this office received your letter dated 12/28/84 which summarized the results of an adequacy test taken on the on-site sewer system on 12/27/84, and also to which was attached the results of a potable water analysis report dated 12/8/84o In several telephone conversations and in our meeting last Friday, March 1, 19857 you have requested that this office grant our approval to this sub- standard system° Your request is supported by the results of the recent ade- quacy teSto. As you are aware, the design criteria of an on-site sewer system is such that a margin of safety is included ~tch is to enhance the longevity of the system° It is a recognized fact that the results of an adequacy test con- Tebben Spurkland, PE March 4, 1985 Page 3 ducted during the early life of a system can be expected to be very good. This early performance is not indicative of the longevity of the system. The design criteria for on-site wastewater systems are very explicit, and this Department is required by ordinance to adhere to these criteria. I am in total agreement with Mr. Bandt's and Mrs° Oswalt's decision not to approve this substandard on- site sewer system° Before any departmental approval will be granted, the existing system must be upgraded. It has recently been brought to our attention that the on-site well serving the subject residence has shown a drastic reduc- tion in productivity and probably does not meet the minimum requirement for a three bedroom single family residence. By receiving a copy of this letter, ~. Frits Meyer has been made aware of the problems with his on-site well and sewer systems, and should take action accordingly° Very truly yours, ~ Robert H. Robinson Manager~ Environmental Health Div±ston Department of Health and Human Seruiees RR1/ka/d4 cc: Mr. Frits Meyer 8437 Jade Street Anchorage, AK 99502 Certified Mail MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME MAILING ADDRESS LEGAL DESCRIPTION LOCATION O~ I DISTANCE TO: ]Well IMa"ufacturer Liq capacity n ga OhS I' ] 0~O IF HOMEMADE: DISTANCE TO: Well PHONE [~NEW Absorption area /~/¢ , Inside length Dwelling / ~ / NC. OF BEDROOMS PERMIT NO. ~ Cp~_~ No, of compartments Liquid depth Dwelling PERMIT NO. Manufacturer Material '~ ,~" Liquid capacity/~ ~'~ ~)in gallons~_~.~ I Well Foundation Nearest lot line PERMIT NO. DISTANCE TO: / ~ ~) No. of lines . / Length of each line Total length of lines I Trench width Distance between lines I .~, ~ 2- '7 I r ~ ~/p inches Top of tile to finish grde ~ ' Material beneat~th ti e Length Width Type of crib Crib diameter Well DISTANCE TO: Depth Z i¢ches Total effective absorption area PERMIT N~), Crib depth Total effective absorption area Building foundation Nearest lot line Class Depth found DISTANCE TO: OTHER PIPE MATERIALS SOIL TEST RATING INSTALLER REMARKS /'~'2",,~~ / J~ ~/~AI Distance to lot line PERMIT NO. Absorption area(s) APPROVED 72-013 (Rev, 3/78) ._. ,-,~----:-- :[ TE ZE.~I- ~EF-. F"EF-:f"I Z F'ERF'I_T T i'.4t3: g: 4 ~.3 R"-7:~-g JF:'GRFflDE E:,FITE I2%:;I.JED: d_'--.,.' .... :..-..,..7~,:~ .',-,.'o4 ~FFI. Z -.Hr~ F . RE:,E:,~7:ESS: 13 0 i"] Z f:'lC:Z F I-!uhk_. FRiTS F'iE'¢ER 8437 JI--IE:,E STI:~:EE3" FINCHORi::IGE., RK 995E~2 2,4. Z.':- 0046 LEGRL DEBCF..'iP: SLIBDI',,,'ISION: NFl LOT: [4i,.'"2 SECTION: J.O TOt4NSHIP: :LRN RflNGE: 4W L. OT %IZE: ~:'---.~]:84. (SLq. F'T. OR ACRES.':, LOT LOCRTI 0t'4: :E:4_~:'F' NR I' C:ERTIF'¢ 'FHf:IT: I FtI"I FRHIL. IR~: [,.lI]q-~ THE REQUIREF1ENTS FOR ON-SITE SEWERS RND WELLS RS SET FORTH E,'"r' THE hlUNICIPRLI'i"¢ OF FINC:HORRGE (l~lOFt) FIND THE STRTE OF FI[r. FISKR. 2. I 1.4:r.L.L INSTRLL TNE S'T"..E;TEH IN RCCORDRNCE WIT!-I RLL I'IOR COPES RND REGULRTIONS, fiND IN COHPLIFihlCE 14ITH THE DESIEiI'.4 CRITERIR 'OF THIS PEF~:['II'T'. ]:. I NILL RDHERE TO RL.L PIOFI RND 'qTRTE OF RLRSKR REC~UIREHENT'S FOR THE SET BRCK DI.STRNCES FROH RN'¢ EXISTING 14ELL, WFISTEkliZlTER 13, ISPOSRL S'¢STEf~I OR PUBLIC SEWERRGE S'T'STEPI C)N THIS OR RN'¢ RD..TRCENT OR NERRBh-' LOT. IF I-q LIFT STRTION IS INSTRLLED IN RN FIREFI COVERED Bb.' i',lClFI BUILDING CODES., THEhl (!t}, FIN ELECTRICRL PERt'alIT RND INE;PECTION I',IUST E:E OBTFtINED.~ (2) RS-BLIILTS klIL. L NOT BE RF'F'RO',,,'ED k!ITHOUT RN EL. ECT¢)ICRL. INSPECTION REPORT.~ I=IND (]:) THE ELECTF..'ICRL NORK f'IUST BE DONE E:'T' R LICENSED EL. ECTR~CIFIN. ~UNI~IPALITY OF ANCHORAGE~ Department Health and Environmenta~i: ~rotection 825 L Street, Anchorage, AK. 99501 Permit, ~ ~',~/'0~ 5~ * * * HANDWRITTEN PERMIT * * * · ~ ON-SITE SEWER PERMIT Legal Description: ~ /~r/~, S~ ~/~ ~/ Lot Size: ~ ~ Type of Soil ~sorption System Is: /~ Trench: ~ Drainfield: Seepage Bed: Holding Tank: __ Maximum N~ber °f Bedr°°ms:~3~-- ~d~ ~4S°il Rating(sq.ft/br)~ ~r~/ ~~ ~ The Required Size of the Soil ~sorption System Is: DEPTH ~ LENGTH / ~ GRAVEL DEPTH ~< WIDTH The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation-(in feet). There is no set width for trenches. The gravel depth is the minim~ depth of gravel between the outfall ~ipe and the bottom of the excavatiOn(in feet). · * REQUIRED SEPTIC(HOLDING) TANK SIZE = ~ GALLONS * * Permit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. · * * TWO(2) INSPECTIONS ARE REQUIRED * * * Backfilling of any system without final inspection and approval by this department will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 feet for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minim~ distance from a private well to a private sewer line is 25 feet and to a co--unity sewer line is 75 feet. Well lo~s are required and must be returned to this department within 30 days Of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. I certify that: (1) I ~ f~iliar with the requirements for on-site sewers and wells as set forth by the Municipality of ~chorage. (2) I will install the system in accordance with codes. (3) I understand that the on-site sewer system may require enlargement if the residence is remodeled to include more that 3 bedrooms. Signe~: Issued by: Applicant SWP/024 (1/81) ~ /~_~ ;'~, ~'~ HOWARD 'rEAL " 344-0498 WATER WELLS 665 W. 87th Avenue Anchorage, Alaska 99502 WELL CONSTRUCTION LOG Drilling Ce. ~'~"- r~" US6S ne. Well owner ~',~¢~Z~ '~/¢'J~N] Nearest community .__~"~ Well Ioc=tion: (,d,ress & local description) ~c~ ~'~ Location sketch or remarks Depth of well ~{-~ ft. Casing: depth ~[~ ft. diam; ~ in. Static water ~vet./~_ ft. (above,~ below) land surface. Dete~ ~ / Finish of well: (open-end, screen, perforated, open-hole, other) Describe intervals and size: for ~ hours with ~ ~ ft. of drawdown fram static level. DRILLER'S MATERIAL LOG Depth below land Dive description of strata penetrated surface in feet (size of material, color, hardness of drilling, and water content) / ;~?~ to p. ZT 9J.,~Lt o¢ kT to to ~}25 "1._" STREET ANCI]IORAG~, At_ASI<A 99501 (90?) 264-4111 January 4, 1982 Frits Meyer 8437 Jade St. Anchorage, AK 99502 Permit ~ 810259 Subject: W2 L12 S. A permit issued by system has expired Permits are issued 10 T12N R4W this department for a well and/or sewer as of December 31, 1981. on a calendar year basis, as stated on the permit, by authority of Municipal Ordinance. If you have drilled the well, a well log should be sent to this department to document the installation date. If an engineer inspected the installation of the on-site sewer system, please have them send us the as-builts for our files. If there are any further questions, please call this office at 264-4720. Sincerely, ~grN~mB~aChnha~le~' Sewer and Water Program Enclosure: Copy of Permit ~4U~-~ It: C; ~ PilL I -r'~ ~-]F I~NCHCI~..'BGE DEPBRTMENT :~% HEFILTH BND ENVIRONMENT~L~--~OTECTION 825 ~ STREET., 8NCHOR8GE., BK. 91..~ ~i 264-4720 ~4ELL P E~:r'~ I =¢;,T ch_ q. S' 0 D- 84=.,' JRDE LOT SIZE 24~-0046 2~204_,~-'=E'IRR~.~ FEET MINIMUM DISTRNCE BETWEEN R WELL RND RNY ON-SITE SEWRGE DISPOSRL SYSTEM IS ±00 FEET FOR R PRIVRTE WELL OR ±50 TO 200 FEET FROM R PUBLIC WELL DEPENDING UPON THE TgPE OF PUBLIC WELL. MINIMUM DISTRNCE FROM R PRIVRTE WELL TO R PRIVRTE SEWER LINE IS 25 FEET RND TO R COMMUNITY SEWER LINE IS 75 FEET. WELL LOGS RRE REQUIRED RND MUST BE RETURNED TO THE DEPRRTMENT WITHIN ~0 DRYS OF THE WELL COMPLETION. OTHER REQUIREMENTS MRY RPPLY. SPECIFICRTIONS RND CONSTRUCTION DIRGRRMS RRE RVRILRBLE TO INSURE PROPER INSTRLLRTION. PERf4 :I T E:~4F" I RES [)EL-:Ef'IBEF: Z::::[.. ~_~-¢- :9:t I CERTIFY THRT 2: I RM FAMILIRR WITH THE REQUIREMENTS FOR ON-SITE SEWERS RND WELLS RS SET FORTH 8Y THE MUNICIPRLITY OF RNCHORRGE. 2: I WILL INSTRLL THE SYSTEM IN RCCORDRNCE WITH THE CODES. S I GNED: .......... ,-~¢_ -~-' ................... RPPLICRNT FRIf~ MEYER ISSUE[:, BY_ --- ) .... ","4. 0 825 "L" STREET ANCItOR,,",,GE, ALASKA 99501 (907) 264-4111 December 31, 1979 Frits Meyer 8437 Jade Street Anchorage, Alaska 99502 Permit ~ 790557 Subject: T12N R4W Section 10 W% Lot 12 A permit issued by this department for well and/or sewer system has expired. Permits are issued on a calendar year basis, as stated on the permit, by authority of Municipal ordinance. If you have drilled the well, a well log should be sent to this department to document the installation date. If an engineer has inspected the installation of the on-site sewer system, please have them send us the as-builts for our files. If there are any further questions, please contact this office at 264-4720. Sincerely, Les N. Buchholz, R.S. Senior Environmental Speci~-- LNB/ljw enc: Copy of Permit PERMIT NO. DEPARTMENT OF HEAl. TH AND ENVIRONMENTAL PROTECTION 825 ~L~ STREET~ ANCHORAGE, AK. 99501 2~4-47~0 ) APPLICANT LOCRTION LEORL FRITS MEYER 84~? JADE ST. Wi?2 OF Li2 SiC TiRN R4N SM LOT SI~E 24~ 004~ ~D~04 SQURRE FEET TYPE OF SOIL ABSORPTION SYS ]"E.~: TRENCH (~.// '= - ( S¢! MRXIMUM NUMBER OF BEDROOMS = ..,JilL RATING FT,."'BR)= 85 THE REQUIRED SIZE OF TH~ SOIL. a~SO~PTZONSYSTEM THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRRINFIE. LD. THE DEPTH OF R TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF: THE GROUND AND THE BOTTOM OF THE EXCAVATION (IN PEET). 7HERE IS NO SET WIDTH FOR TRENCHES. THE GRRVEL DEPTH IS THE MINIMUM bEPTH OF GRAVEL BETWEEN THE OUTFRLL PIPE AND THE BOTTOM OP THE EXCAVATION (IN FEET). PERMIT RPPLICRNT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE INSTAL. LRTION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY RND THE NUMBER OF RESIDENCES THAT THE NELL WILL SERVE. .... TNr_~ (;~) I ~SPF. E]CTIO~S ARE RE~UI F<EI} BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION, MINIMUM DISTANCE BETWEEN R WELL. AND ANY ON-SITE SEWAGE DISPOSAL,, SYSTEM IS i00 FEET FOR A PRIVATE NELb OR i50 TO 200 FEET FROM 8 PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL.. NELL LOGS RRE REQUIRED AND MUST BE RETURNED TO THE DEPARTMENT WITHIN ~0 DBMS OF THE NELL COMPLETION. OTHER REQUIREMENTS M8Y RPPL. Y. SPECIFICATIONS AND CONSTRUCTION DIRGRRM~ ARE AVRILABLE TO INSURE PROPER INSTALLATION, I CERTIFY THAT l: I AM FAMILIAR NITH THE REQUIREMENTS FOR ON-SITE SENERS RND WELLS AS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTALL I'HE SYSTEM IN ACCORDRNCE WITH THE CODES. .~: I UNDERS?AND THAT THE ON-~IT~ ~ENER SY~TEH NAM REVUIRE ENLARGEMENT IF THE ,, RESIDENCE IS REMODELED TO INCLUD~ MORE THAN ~ BEDROOMS. i~ ~ ~ .................... ....................... . .. I SSL PLAN 0 I,"~';HINE -- PRODUCT MATERIAL {~] ,dESIGN [~] CONSTRUCTION A4,~,,4, /~/~/s/a,_~"~t~'~7'__~ ... Inspector's Daily Report Name of Project ~ Location of Project RESOURCE DEVELOPMENT Contractor Superintendent Equipment Personnel Supertendent Electricians Operators Plumbers Oilers Surveyors Labors Other trades ,,. Carpenters .<~ ]~isc. Others Teamsters TOTAL ~N ON T:&E JOB Con't on the back side° Orders or Comments given to the Contractor Remarks or General Comments / Inspector's Signature Title ~ /.. m ............ , ~'~,. .................... PLAN O' ---.~q~ACltlNE J, ', [' ~L' . '" '] :[: DESIGN ~ ] CONSTRUCTION · ANCHORAGE, ALASKA 9950! Inspector's Daily Report PRODUCT _.~ RESOURCE DEVELOPMENT TELEPHONE 907-27/~-5235 Superintendent ~ ~ ~. Equipment Percor~nel Supertendent __ Operators Oilers Labors Carpenters Teamsters Electricians Plumbers Sum~veyors Other trades I~isc. Others TOTAL ~31J ON 'filE JOB Con't on the back side, Orders ar Comments given to the 0ontractor Remarks or General Co~aents Inspector's Signav~e Title SOIl.. DESCRIPTION SURFACE: ELEV .... ~ ....... BARNARD--MARTH 81 ASSOCIATES--205 WEST ISTN AVE.--ANCHORAGE 0 ~---~" t-,q ~9 ° ~5~' W CERTIFICATE OF SURVEY ROADWAYS,~RANSMISSION LINES OR OTHER VISIBLE EASEMENTS ON SAID PROPERTY AS INDICATED HEREON; DATED AT ANCHORAGE, ALASKA, THIS ~ / DAY OF L//~/~, , t HEREBY CERTIFY THAT t HAVE SURVEYED THE FOLLOWING DESCRIBED PROPERTY: AS RECORDED IN THE ANCHORAGE RECORDING PRECINCT, ALASKA, AND THAT THE IMPROVEMENTS SITUATED THEREON ARE LOCATED AS SHOWN ON THIS PLAT, AND 'THAT THERE ARE NO EXCEPT BARNARD ENGINEERING CONSULTING ENGINEERS · SURVEYORS 203 W. I§TH AVE. ANCHORAGE, ALASKA . 99501 PHONE 274 -5255 FOR: ~P-. ITT--. -FND- /" R. EBAI--;. /7 SCALE: DRAW. BY: ,JF' CHECKED BY,/'z/~ aDB NO, 9-09~ GRID NO. ~. • • PAGE (3„/ • Municipality of Anchorage On-Site Water and Wastewater Program R • (907) 343-7904 s,. CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 011-161-29 Expiration Date: 1 r IGULCXI 0 to 019 1. GENERAL INFORMATION Complete legal description T12N R4W SEC 10 LOT 12 W2 Location (site address) 8437 JADE STREET,ANCHORAGE,AK 99502 Current Property owner(s) BYRON BIRDSALL REVOCABLE TRUST Day phone Mailing address 8437 JADE STREET,ANCHORAGE,AK 99502 Real Estate Agent Day phone 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 TYPE OF WASTEWATER DISPOSAL: 4. TYPE OF WATER SUPPLY: Individual Individual Well ® Holding Tank ❑ Individual Water Storage ❑ Community ❑ Community Class_Well ❑ Public Sewer ❑ Public Water System ❑ WaiverNariance request for: Distance: Received by: /% / //i!j! Date: /VV, g7 COSA to be released to the engineer,unless other*l e•.2' ted by the engineer. COSA Fee $ 5240 Waiver Fee $ Date of Payment t r 130 fig Date of Payment Receipt Number (�5�a,�b Receipt Number COSA# 0 5C/0402_9 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm ARCTERRA CONSULTING,INC. Phone 868-3791 Address 20441 PTARMIGAN BLVD., EAGLE RIVER,AK 99577 Engineer's Printed Name KENNETH M. DUFFUS Date 10/13/2018 THIS COSA DOCUMENT CANNOT BE USED TO TRANSFER TITLE UNLESS ALL VENDORS(ENGINEERING,SURVEYING,CONTRACTORS,ETC...ASSOCIATED WITH THIS COSA ARE PAID IN FULL AT OR BEFORE CLOSING. Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that may fluctuate during the year and the water usage of the family being served by the system. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, ArcTerra can not give any estimate of how long a system will function satisfactory for current or future occupants or can ArcTerra guarantee that no unseen encroachments,deficiencies or discrepancies exist. 01:•, 4l • # 6. DSD SIGNATURE / ��rd / J System #1 Approved for 'lJ �'2% bedrooms. ` System #2 Approved for bedrooms. r1 cr:•NENNEIfi 111, "� _ % /a /5 /a , - Disapproved. pEsstcs``' Ilk NIL Conditional approval for bedrooms, with the following stipulations: j ON-SITE L. • WATER AND 5' 11 WASTEWATER o R� �PROGRAM 2 J. By: C9.7ta9 Original Certificate Date: ,1)€C 0(o a 0 l E The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet_10-10-12.doc If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: T12N R4W SEC 10 LOT 12 W2 Parcel ID: 011-161-29 - A. WELL DATA Well type PRVT If A, B, or C provide PWSID# Well Log (Y/N) Y _ Date completed 5/7/1981 Sanitary seal (Y/N)Y Wires properly protected (Y/N)Y Total depth 265 ft. Cased to 265 ft. Casing height(above ground) 18+ in. FROM WELL LOG AT INSPECTION Date of test 51711981 6111/2018 Static water level 120 ft. 124 ft. Well production 5 g.p.m. 4+ g.p.m. WATER SAMPLE RESULTS: Coliform NEG colonies/100 mL Nitrate ISD mg/L Arsenic: r1.04 ug/L Date of sample: tt]a o J a 618 Collected by: ARCTERRA B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC 1 STEEL Date installed 7/16/2018 Tank size 1500 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout(Y/N)Y Depression over tank (Y/N) N High water alarm (Y/N) N Date of pumping NA-NEW TANK Pumper C. ABSORPTION FIELD DATA Date installed 6/29/1987 Soil rating (g.p.d./ft2 or ft2/bdrm) 125 System type SHALLOW TRENCH Length 54 ft. Width 5 _ ft. Gravel below pipe 3.5 ft. Total depth 8 ft. Eff. absorption area 500 ft2 Monitoring tube Y Depression over field N Date of adequacy test 6/11/2018 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 0 in. Water added 750 gal. New depth 0 in. Elapsed Time:0 min. Final fluid depth 0 in. Absorption rate >= 600+g.p.d. Any rejuvenation treatment(past 12 mo.) (Y/N &type) N If yes, give date. -_ D. LIFT STATION Date installed _ Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at _ in. High water alarm level at _ in. Datum Cycles tested _ Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot _100'+ On adjacent lots 100'+ Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main 75'+ Public sewer manhole/cleanout 100'+ Sewer/septic service line 25'+ Holding tank 100'+ Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPTIC/HOLDING TANK ON LOT TO: Building foundation 10'+ Property line 5'+ Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main 10'+ Water Service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+_ Curtain drain 50'+(NONE KNOWN) Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSHuidelines in effect on this date. 9 OF At \ Engineer's Printed Name KENNETH M.DUFFUS Date 10/13/2018 * 4 TI I /\ * coSA canary sheet_2-6-15.doc KENN 'TII71I.'• 4 / 4 /5/,TsS `__f LOT 1 N N N N N N , _ 47r1M11.1.••••• .M. . m••• ..... WEST 84TH AVE w CA I o S89°57'00"W 132.49' e V 33' R.O.W. ESMT i,jfis4 j". I LOT 1 • 4 I • too to 8 - o o • o 0 (.0 -' v+ • SEPTIC 0 ow x VENT LOT 2 - o I m tri m WEST V2 to LOT 12 CI) � 1-3o H rii to • i-3 44.0' 46.2' CO I PAVED o 01W N EXISTING o s.o' HOUSE N - - LOT 3 (No w.o' 00 J CONL / �� WALKK CANTcNCANT I ' 67.9' GRDA1WL CANT �,.r O x I20.0. 17.7' x ®WELL I In x to N wo �� LOT 4 I • 11.6' x I g X v-"-v v Lv v v v v v 0 I 33.00' ::1 S89'40'02"W 132.38' x LOT 17 ANCHORAGE RECORDING DISTRICT,ALASKA ASBUILT OF: WEST 1/2 LOT 12 O =FND REBAR NE1/4 SW1/4 SEC10 T12N R4W S.M.ALASKA `__``.A` SURVEY CERTIFICATE:I,John L.Schuller,Have conducted a A OF 4 `, yo LAmOD S, .., physical survey of this property as shown on this drawing and that the or .• improvements situated hereon are within the property lines and no if<�' ��C. S ', ,y,w1 4,.'�,�, enchroachments exist other than noted.Under no circumstance should 0*:' 49 /\ , Na .0 any information on this drawing be used for construction of fences, ! ►�a y. structures,improvements,or for establishing boundary lines. / C I / u V Q Cr„� EXCLUSION NOTES:It is the owners responsibility to determine3 �° �'(�. oo •.J L. SCHULLER. °/ = I the existence of any easements,covenants,or restrictions which ,�. . . �A,, •,, IS-10408 v do not appear on the recorded subdivision plat. i P^ • .§00 �� 1831 Talkeetna Street WORK ORDER NUMBER: DAIS ecce E-MAL: ,f eo, '••,,;/9.•;(8• a�/ Anchorage, Alaska 99508 SEPT 19, 2018 1"=40' \` At� 18-059 �W+BY:CHECKED sr.CRID IR* BOOK/PAGE ‘�`°fessiono` %�� (907) 227-1455 office JLS 2324 180223 \\����� (907) 274-4992 fax