HomeMy WebLinkAboutPEPPERS ACRES LT 1Onsite File #011 am 152 am 33 Municipality of Anchorage On-Site Water and Wastewater Program • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181306 PID Number: 011-152-33 Dwelling: ❑E Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New 9 Upgrade Name: Dwiggins Judith Marital Trust ABSORPTION FIELD ❑ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound Address 8721 Emerald St Anchorage, AK 99502 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 274-1642 4 GPD/SF Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Ft. Gravel depth beneath pipe Ft. Subdivision Block Lot Peppers Acres L1 Fill added above original grade Ft. Gravel length Ft. Township Range Section Gravel width Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line Ftz Ft. Well >100' N/A N/A N/A >25' TANK F21 Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Greer Capacity 1250 Gal. Surface Water >100' N/A N/A N/A Material Number of compartments Lot Line >5' N/A N/A N/A Steel 2 NA Foundation 7.5' N/A N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. Remarks Septic tank only Pump on level at in. Pump off level at in. High water alarm at in. Pump make and model Electrical Inspections performed by Installer PIPE MATERIAL House to tank D3034 Tank to drainfield D3034 Isaac's Excavating Services LLC Drainfield CO/MT 0303y Inspector Ben Schiller BENCHMARK (Assumed elevation) 100 ft Inspection nd 1s' 9-29-18 Location and description 2 3rd 4th Edge of conc deck COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp `Cal OF Conditional Approval: Date , a �Q TH • *. enjaniVSchiller ApprovedvcJt, Date 11311 � ��(] �•. CE 12592 � F� � i ��l . • 4/16/19 . • '�G�� ���®� PROFESSkQ0 111bl uLmuII r%t=y UII_7-I-IL.UUU O w w QUA wi00 w O= O O p ZD JoUo0- z w w w U cn 1— 000 ' ui O N u- 2i Ui 1-- M m 1 N Ln cfl d- Ln m m " ici m N co N N 1 M O N O Fz o w z 1 Z W /� d VJ ," OO a n. w W w U) O twi ry 01, CO a� zCO z � ~O :� � U W m 0 W o 0 n o _� w_ N 0 J z C`7 0 0 - �Q 0 W co Ab LL nLO , 0 O o 11 CD CO / O O cm 75 ry �6 W n s J ti "Ile 9 m Al PEPPERS ACRES, LOT 1 mmwmnw. • : �. PID # 011-152-33 ENGINEERING PROFILE AS -BUILT (NO SCALE) TH ... sic. I Benjain Schiller �Fe CE 12592 /J� 111. 2.19 ��_�° Municipality of Anchorne P.O. Box 196650 a 4700 Elmore Road Anchorage, Alaska 99519-6650 s (907) 343-7904 ® Fax (907) 343-7997 http://www.muni.org/Onsite Development, Services Department On -Site Water and Wastewater Section .111CI1f n Department * * * * VARIANCE/WAIVER REVIEW * * * * Waiver#: OSV191017 COSA#: Permit#:OSP181306 PID#: 011-152-33 Legal Description: Peppers Acres Lot 1 Engineer: Forge Enqineerinq Applicant: Judith Dwiggins Marital TrustMarital Trust Your request for a waiver of the required 10 feet horizontal separation from the septic tank to the building foundation has been approved. The approved separation distance is 7.5 feet. See engineer's waiver request for justifications. This waiver approval applies to the existing septic tank only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ....................................................................:......... t Waiver is Granted: X Waiver is not Granted: Date: 5 0l y l / Approved by: _,U,Ua Name of Reviewer **** VARIANCE/WAIVER REVIEW **** May 24, 2019 PO BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) FORGECIVIL.COM MOA Development Services, On -Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Peppers Acres Ll — 8721 Emerald St Foundation to Septic Tank Waiver Dear On -Site Services Engineer:, OF At "kk It TH Benjar>iLr�,,&hiller 19F� % CE 12592 F�PROFESSIONP The existing septic tank on the subject lot was recently replaced with a new 1,250 gallon tank. It was not possible to place the new tank 10' from the foundation due to the location of the existing tank and the depth of the excavation- to avoid creating a giant hole, we had to place the tank in the same spot. A small section of the new tank is 10' from corner of the building, just where the old tank was. The attached drawing illustrates the septic tank and its location in relation to the house foundation. As we did not expose the footing, we do not know how far down it extends. The ground slopes down sharply in this area toward the back yard, so we anticipate the footing to step down deeper than normal. Even so, the influence line of the footing and foundation when projected down at a 1:1 slope might encroach some into the new septic tank. However, as this septic tank is replacing a tank that existed in this location for several decades, it is unlikely that the location of the tank will have any influence on the foundation. In addition, we can verify that the soils were not sloughing during the deep excavation, so if the tank integrity were to be compromised it would not cause a complete collapse of the soils. The foundation would not be in danger. We hereby request a waiver be issued allowing the septic tank- to remain in its current location. Sincerely, Benjamin Schiller, PE OSV•1110i ,'a25 eo'J y f 11J ;ott_P `'' Of. MUNICIPALITY OF ANCHORAGE �1ent ' On-Site Water&Wastewater Program `o 0- PO Box 196650 4700 Elmore Road ® ; Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 ,. http://www.muni.org/onsite ccr ' 1) parfnicnt ,hc•f OR AVE On-Site Wastewater Disposal System Permit Permit Number: OSP181306 Effective Date: 9/7/2018 Work Type: SepticTank Upgrade Expiration Date: 9/7/2019 Tax Code Number: 01115233000 Site Legal Address: PEPPERS ACRES LT 1 G:2325 Site Mailing Address: 8721 EMERALD ST, Anchorage Owner: DWIGGINS JUDITH MARITAL TRUST Lot Size in Sq Ft: 77024 Design Engineer: FORGE ENGINEERING Total Bedrooms: 5 This permit is for the construction of: ❑ Disposal Field 0 Septic Tank 0 Holding Tank 0 Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: 14 �',i, � "/ `�, Date: 9 Issued By: ! ( Date: �/% MUNICIPALITY OF ANCHORAGE Community Development Department '\ . 1r,/ Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On-Site Water & Wastewater Program ON-SITE SEWER/ WELL PERMIT APPLICATION Parcel I.D. 011-152-33 Property owner(s) Judith Dwiggins Marital Trust Day phone 274-1643 Mailing address 8721 Emerald Street Anchorage, AK 99502 Site address Same Legal description (Sub'd., Block & Lot) Peppers Acres, Lot 1 Legal description (Township, Range & Section) Lot Size 77,024 Sq. Ft. Number of Bedrooms Five (5) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (©all that apply) Absorption Field H Initial I I Single Family (SF) X (w/wo AD U) Septic Tank X Upgrade I XI Duplex (D) Holding Tank Renewal Multiple Dwellings Privy n (SF and/or D) Private Well I Water Storage I 1 THIS APPLICATION INCLUDES A VARIANCE I WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: LL5 Waiver Fees: Date of Payment: e I5I,1Date of Payment: Receipt Number: O -1(0O I 1-3 Receipt Number: Permit No. C6101,17t3GL Waiver No. Permit App_:- • c, 'l 8 9 /0 ,A)\" . . 1 a BOO e M' SE.i' it ZU'itl t GE ENGINEERING . PO BOX 240773 �4 ANCHORAGE,AK 99524 6 522-7773 677-7766(FAX) September 3, 2018 Municipality of Anchorage Development Services Dept.- On-Site Water& Wastewater Program 4700 Elmore Rd Anchorage,AK 99507 Subject: Peppers Acres,Lot —8721 Emerald Street Septic System Design and Permit Application Dear On-Site Services Engineer: The septic tank on the subject lot is leaking and must be replaced prior to the issuance of a COSA for the property. The attached site plan identifies the location of the home and the existing well and septic system. No conflicts exist between this proposed system and any other well or septic system,whether on this lot or adjacent lots. The septic tank currently in place is 1,250 gallons. The new septic tank will be 1,500 gallons and will be placed a minimum of 5' from the south property line. The existing well on the lot is shown. The placement of the new septic tank will not encroach into surrounding protective well radii. Please refer to the attached plan sheet for the septic design. If this design is followed,there will be no adverse impacts to adjacent properties. Sincerely, v\\ pFAgyAk -vo Michael E. Anderson, PE 0*: 49 TH '. Michael E.Anderson : �Vs.. 4381-E •�c��% 1iIV1 pROFESSlONA4i PEPPERS ACRES, LOT 1 I I i 1 1 T12N R4W SEC 10 LOT 71 I I (UNDEVELOPED) 10.T.BE. \ I EASEMENT \ / \ \ LOT 1 \ a- I EXISTING WELL 1 I I- . EXISTING ABSORPTION TRENCHES w (EXACT CONFIGURATION UNKNOWN). 1 w 5-BDIRM W I HOIV1E I\ I- f NOTE: C' DECOMMISSION EXISTING SEPTIC TANK IN 0 O' s �� CONNECT TO EXISTING ACCORDANCE WITH M.O.A.CODE.; \Q L_ EXISTING 1.250 GALLON <�SV 0 SERVICE LINE. SEPTIC TANK. /TCO SV -- -1.. 00 GALLOP(SEPTIC TANK. 1 w \ I/ / MINIMUM 5"FRO PROPERTY LINE. A 1 f J - \ /'i — — 112N RAN SEC 10\IcOT 35 /'I .�44� '.. NOTE: LEGEND •��P......................... " �•40 NO SLOPES SURFACE WATER WITHIN 100'OF THE PROPOSED SEPTIC SYSTEM CO-CLEANOUT so �'.-•• •s •� 2C0-DOUBLE CLEANOUT 49th •. ,.•% ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH FCO-FOUNDATION CLEANOUT :•• a :. ..� _ MT-MONITORING TUBE � •��.�� WELLS OR SEPTIC SYSTEMS. •7"r'yICHAEL E. ANDERSON�:'t., •r^= r �4`� 0 50 100 SV-SEPTIC VENT �.�%i';• No. CE-4381 ..2's TH-TEST HOLE Sj F,p •.., 9-7-18 ••' .'m? . . . . FEET Fo ...........�• GE ,_ , ��••� OFES�ku-�• I M G, .I. N G 1"=50' Anchorag P.O. [' :, 196650 ANCHORAGE, ALASKA 99519-6650 (907) 264-4~t~:k 4 7 4 4 TONY KNOWLES. MAYOR DEPARTMENT OF HEALTH & HUMAN SERVICES January 9, 1987 Neil Hawthorne 7127 Old Seward Highway Anchorage, Alaska 99518 Subject: T12N R4W Section 10 Lot 72A On-site Sewer Permit #860210 Don Dwiggins Property A permit issued by this Department for an individual well and/or on-site sewer system has expired as of December 31, 1986. Permits are issued on a calendar year basis by authority of Municipal Ordinance. A new permit must be obtained from this Department for any well and/or on-site sewer system not installed by the expiration date. If you have drilled the well, a well log needs to be sent to this Department for documentation of the installation and to close the permit. If a private engineer inspected the installation of the on-site sewer system the original as-built inspection report (three part form) must be sent to this office for review and approval, and for documenta%ion. If there are any further questions, please call this office at 264-4744. Since~r~ly~ R.W. Robinson Program Manager On-site Services RWR/ljw enc: copy of permit DEPARTMENT OF HEALTH AND ENVIRONMENTAL. PROTECTION S25 L STREET~, ANCHORAGE, Ak:: 99501 2.64-4720 · 86'2'" IdO!...DING ]Ah.i, API::)L I CAIq'T ~ ADDRESS: CONTACT F:'HOIqE: DON DWIGGINS C/O N HAW'FHORNE 7127 OLD SEWARD HIGHWAY ANCHORAGIE, AK 99518 344-4711 SUBDIVISION: NA L.OT: 72A SECTION: 10 TOWNSHIP: :[2N RANGE: 4W 31500 (SQ.FT. OR ACRES? EMERALD STREET BLOCK: NA I am i'am:i, lia;' with t. he pequir'emer'its fop on-,site eewer-e and wel].s as set i'cmth by the Munic:ipalit. y oi' Anchor'age (MOA) and the State oF Alaska. 2. I ~:i.],:i, install the eystem in actor-dance with ali. MOA c:odes and ~-egulat:i. ons, and ¢.n compliance ~¢i'l'.h the design c:Pite~'ia of this pea*mit.,, I will aclhepe to all MOA arid St. ate of Alaska r. equir'ements l'of t. he set bac:k distances fpom any 6)xieting t¢~e].].s was'kewat, er' d:i. spoeal system 6)p pLtblJ, c ~;et*~6-n'age system o~i this or. any acljac:6~nt cap near'by lot. ]:1::: A i...IFT SI'A'I"I(]Iq IS IIqS'/ALLED IN AN AREA COVERED BY MOA BLJILDING CODEES, THEN (!) AN ELIECTRICAL PEERMtT AND INSPECTION MLIST BE OBTAINED; (2) AS-BUILTS WILL. NOT BE APPROVED WITHOLFF AN E:LECTRICAL- INSPECTION REPORT; AND (3) THE ELEC'TI:RICAL WORK MUST BE DONE BY A L..ICENSED EELECTRICIAN. N -IAWTHORNE ENGINEERING 7 ! 27 OLD SEWARD HIGHWAY ANCHORAGE, AlaSKA 99502 907-344-4711 July 1, 1986 Ms. Susan Oswalt Anchorage Dept of Health & Human Services Box 196650 Anchorage, AK 99519 Re: Lot 72A, S10, T12N, R4W Dear Susan: Please consider this a request for a permit to install a holding tank on the referenced property. I believe that the original trench was improperly installed and inspected in 1979 beca~se the bottom of the test hole was at about elevation 93 ft. (datum assumed) while the bottom of the trench is at about 90 ft. elevation. That is about 10 feet below the water level of Jewel Lake, 150 feet away. There is not room for a mound system and the well separation radius prevents use of the higher portion of the lot. Please find all pertinent paperwork enclosed. Thank you. Nell Hawthorne, PE NH:ck Enclosures  MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT ? ' [] UPGRADE LEGAL DESCRIPTI(~N ' ____.~: DISTANOETO: IWell /~?d ("'/- I PERMIT ~ Man u fact u ret ~')g~ Mater,(.~ ~.~ No. of compartment~ Liq' 7~P~-~:~JalJ°ns IF HOMEMADE: Ii, slde length Width Liquid depth ~ ~ DISTANCE TO: Well Dwelllng PERMIT NO. O 2~ <~ Manufacturer Material Liquid capacity in gallons ~i~ DISTANCE TO: Well/~of each ' line Total Foundatlon~>~_~ ~, lengt f line Nearest lot line/~/" -- NO, of lines / Length ~.~ ~ Trench wi~.~ inches Dista,ce batw~7~s El~, ,,.¢ ~' Material beneath tile~o inches ~' ~ ~ Top of tile to finish grade/~/.j Total effective adsorption area Length Width Depth PERMIT NO. ~: F- Type of crib Crib diameter Crib depth Total effective absorption area Lu Well Building foundation Nearest lot line u~ DISTANCE TO: .~ Class Depth Driller Distance to lot line PERMIT NO. ~ DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s) OTHER PIPE ATERIALS APP~ DATE LEGAL 72-O1~ Rev. 3/78) Well Owner_ ~., ! JVJ-W DRILLING, Inc. P.O. BoxZ!-1224 * 1310C InteJnatJonalAiJpoi'L Road (907) 274-4G1] ANCFIORAGE, ALASKA 99509 Don Dwiggins DRILLING LOG MUNICIPALITY OF ANCHORAGE DEPT. O7 ;iE'I.Ti! & ENVIRONMEi,d, .... CTION Location (address of: To~vnsbip, Range, Section, if known; or distance main road Lot 72 Sec. 10_T~ixL~R4W~S~M Size of casing_ Static water level 75 Screen ( ); Describe screen or perforation~/A Well pumping test at 50+ gallons per of drawdown from static level. Date of completion __ 7 / 3 / 79 Depth of Hole 2~B ___..feet Cased to~237 3 feet ft. (x~) (below) land surface. Finish of well (cbeck one) open end (xx Perforated ( ). (minute) for. 1 hours with 100% WI~LL LOG Depth in feet from ground surface G/ge details of formations penetrated, size of material, color and hardness __0 _. TO. 2 Casing s tickup _~_ TO 3 _ 3~ 'to 18 18 TO 43 0rB~nics Sand g~avel Sand __4.~_.?o 105 105_ TO. 125 125 TO. 160 _}~0 TO 230 23~ TO 238 TO TO. .TO TO__ .TO_ .TO sand S tickv__clay_: gray Damp silty, sand Bllue clag _~at~r gr_gvel 1--CUSTOMER THE LENGTH DI!'"IENSIOH tS THE [._ENGTH (:IN FEE'F) OF THE "[F;:iEt",![::H OR [>F;'.I'::t!HF!EL[:'. THE [:,EF'TH OF FI TRENC:H OR F'IT IS TFIE [:, :[ :i~;TFINCE E=E"I'HEEN TH!E SIJI::;:FI::ili:E I;.)F: THE GI;?OI..Ih!D FIi",![:, THE EffY'I'TOM OF THE EHCFI',,,'FI-F ! ON ,:: THERE IS NO SEF I.,IIDTH FOR TF'.ENCHE:S. THE GF;'.FI'v'EL DEPTH ]25 THE: MIH!HUM DEF'TH OF: f~iF'.F!',,,'EL. E~ETHEEN THE OUTFFiI..i.. F']:F'E FIt",!C, THE BOTTOM OF THE EHCFIVFF¢]:r)N ,::~h,1 FEET). PERMIT FiPF'LICFiNT HFIS THE RESF'OHS~E~ZL.ZT'¢ TO INF'ORM "f'I..I~S DEF'FIRTI,1ENT [:,L.IRtt'.,IG THE :( NSTRLL.FIT ~ Oi'.,! I NSPEC-F Z OI'-,!S OF FII',!'./ HELL. S RC, J'FICENT -f'O -FH ;[ S F'ROF'ERT'./ FtI'.,I[:, THE t'.,IUME~ER OF RE:Si!i>!ENCES THFIT THE HELL. HIL.I... SERVE. [:=RE:KF ;(L.L I NG OF FIN"r' S'./STEH P.I I THOUT F Z NRL ): NSPECTI 0!",I RN[> F:IF'PRO',/F!L E',V TH I S DEI.:'FIFTI'HENT HIL. L I:3E StJEh~ECT TO [:'RO'i;!:ECIjTZON. HZI'.4ZHUH DZSTFiRIC:E [3ETI.,.IEEH F:I HELl_ FIHD :[J}O FI{ET FOR F:I P?.Z',,,'FITE HEL.L..~ i5~) TO 2:Elei FEET FROM F:I F:'LIE;LIC HEL. I. DEF'[:P,!D:(NG UF'ON THE T'.r'PE OF PUBLIC: H[EI.i_ HELL LOGS FIFiIE [~:~)]:!I_JZf;~:E[:, Iai'q[:' fdI..tST BE RETI. JFe. NE[:, TO THE D!EPFIRTHENT t4!THZN :ii:~;~ DFI"r'S 8F THE NELL. COHF'METZON. Er[HER REg]UZREMENTS MF!¥ F:IF'F:'L¥. '.~;PEC:IFZCFIT);CIN:5 FIND [~¥!::iII_.FII3LE TO I HSURE PROPER 3: Z I...INDERSTFIN[:, f'HFI-[ THE .. !E:ESH>iENCE I:2 REMO[:,ELE[:' T3 II"IC~ [':,E' HORE: THFff',I 5 Alaska Testlab 4040 "B" Street Anchorage, Alaska 99503 Telephone (907) 562-2000 April 177 1986 Health and Human Services 825 "L" Street Anchorage, Alaska 99501 Attention: Ms. Laura J. Ward MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & ENVIRONMENTAL PROTECTION APR 2 g, 1986 RECEIVED Subject: Erratum - Legal Description of Percolation Test Dear Ms. Ward: In 1979 we performed a percolation test for Mr. Don Dwiggins (ATL Work Order No. A18915). In our report of the test, we identified the legal description as Lot 72, Section 10, T12N, R3W, S.M., snd we understand this is the legal description you have the report filed under. This legal description is incorrect. The correct legal description is Lot 72, Section 10, T12N, R4W, S.M. We apologize For any inconvenience we may have caused you for our incorrect identification of the range. Sincerely, ALASKA TESTLAB Melvin R. Nichols, P.E. President MRN:kf cc: Mr. Don Dwiggins Design Plus 4040 "B" STREET ANCHORAGE, ALASKA 99503 (907) 278-1551 June 12, 1979 W.O. ~A18915 Grid #2224 Design Plus 4446 Business Park Blvd. Anchorage, Alaska 99503 Attention: Don Dwiggins Subject: Subsurface Investigation for Suitability of On-Site Sewer, Lot 72, Section !0, T 12N, R ~W, S.M. Dear Mr. Dwiggins: ~ Transmitted herein in accordance with our agreement are the results of the above referenced investigation as performed by us on March 13, 1979. The scope of this project is the investigation for sui'hability of an on-site sewerage system. Included in ~his transmittal are: Test Hole Location Sketch Test Hole Log Explanatory Information Figure 1 Table A Sheets 1-3 · he exploration was conducted using a continuous flight? solid stem auger drilling rig, owned and operated by Denali Dril.~2n~, Inc. .Drilling was supervised, the test hole logged, and pe~coiation test performed by Mr. O. Hatch, Alaska Testlab geologist/senior field technician. The log of the test hole is included as Table A of this report. In iDterp~-eting the log, it would be helpful to utilize the explana~- tory .lnxormat~on contained in Sheets 1 through 3 of the report. When drilling was completed a 3/4" slotted PVC pipe was inserted ~n ~he hole to aid in determining the free water level. For th~ percolation test, the test hole was filled wi~h water and left overDigbt to saturate. On returning the next day~ the hole was reft[lied with water and the drop in the water level carefully monitored over the next 60 minutes. This procedure is not a standardized percolation test, however, we understand that the Municipality of Anchorage~ Department of pt~.b[~.i(; ]~ealth and Environmental Protection prefers tests perfo:cmed_ in 3chis manner I.:o evaluate a site for a proposed, on-slhe sys tern. ~.Design Plus June 12, 1979 Page Two Using the above test, the observed minimum percolation rate was 0.8 minutes/inch. We recommend that the system be designed for an absorption area of 100 square feet per bedroom provided the trench bottoms in gravel at a depth of 11 feet or more. If the trench does not extend to-~e~atively clean gravel this recommendation does not apply as the sandy silt has a much lower permeability than the underlying gravels. This recommendation is based on criteria in the "Manual of Septic Tank Practice", U.S. Department of Health, Education and Welfare, Public Health Service. No water table was observed during drilling. A wet zone was encountered at 15 feet; however no free water was observed in the test hole four days after drilling. We recommend that the seepage trenches be inspected prior to installing the system as the above recommendations 'are based on a six inch test hole. The seepage trench will provide a much clearer picture of the subsurface conditions than the test hole. If conditions are different than encountered in the test hole, it may be necessary to modify the design. We hope %his report meets your present needs. If we can be of further service, please feel free to contact us. Very sincerely, ALASKA TESTLAB James R. Finley, Jr. Geotechnical Engineer Approved: Laboratory Manager PE JRF/ms Enclosures ~9.5o .... 7O .~ KE'rc~H ~l Test Hole .#1 Table A WO #A18915 Date: 6/7/79 Logged by: O. Hatch Depth in Feet From To 0 1.0 1.0 10.0 10.0 15.0 15.0 19.0 Bottom of Test Hole: Frost Line: Free Water Level:- Soil Description F-4, Brown Sandy Silt, damp, soft to stiff, non-plastic, ML F-4, Brown slightly Gravelly very Sandy Silt, damp, stiff, non-plastic. Grades plastic at 8 feet, ML NFS, Brown Sandy. Grave]_, damp, medium dense, maximum particle size = 3", GP F-2, Brown Silty Gravell~ fine to coarse Sand, wet, medium dense, maximum particle size = 2" 19.0 feet None Encountered Sa. No. Depth 1 4 2 9 3 14 4 19 Blows/6" Type of M% Sample G G G G Dry .Strength Group Unified ML ML GP GM Remarks: 2. 3. 4. 5. Dry Strength, .N=None, L=Low, M=Medium, H=High. Group refers to similar material, this study only. General Information, see Sheet 1. Frost and Textural Classification, see Sheet 2. Unified Classification, see Sheet 3.