HomeMy WebLinkAboutT12N R4W SEC 9 W2SW4SW4T12N R4W W2 W4 W4 ¢ 011-271 -01 Permit Number: Tax Code Number: Work Type: On-Site Wastewater Disposal System Permit OSPl11140 01127101000 Septic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Upgrade Permit Effective Dates: July 20, 2011 to July 19, 2012 Design Engineer: SPURKLAND ENGINEERING Subdivision: T12N R4W SEC 9 Site Legal Address: T12N R4W SEC 9 W2SW4SW4 G:2322 Owner/Address: GROPP DORA L 6728 W DIMOND BLVD ANCHORAGE AK 995023903 Site Mailing Address: 6728 W DIMOND BLVD, Anchorage Lot Size in Sq Ft: 579940 Total Bedrooms: 5 This permit is for the construction of: Y Disposal Field N SepticTank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: Tank baffles are to be replaced. Special Provisions: Pit well is not allowed and is to be upgraded prior to Inspection Report approval. Received By: /~ '~ Issued By: k~-~ ~/~,/'~~ Date: UNICIPALITY OF Community Development Department ~.,,2'// Development Services Division On-Site Water & Wastewater Program Mayor Dan Sullivan ANCHORAGE Phone:907-343-7904 Fax:907-343-7997 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. Ol~.- Z~q -01 Property owner(s) hole Mailing address 6, f~ Z~ Site address '- ~ Am 6- Day phone 4F,, Legal description (Sub'd., Block & Lot) Ti 2. N ~ t4'¢J Sec. c~ . W Z. Legal description (Township, Range & Section) Lot Size Sq. Ft. Number of Bedrooms THIS APPLICATION ([~ all that apply) Absorption Field Septic Tank Holding Tank Privy Private Well Water Storage IS FOR: THIS APPLICATION IS AN: Initial [] Upgrade [] Renewal [] THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owne or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. Waiver Fees: Date of Payment: Receipt Number: Waiver No. G:\Building\On Site\Forms\Client Forms\Permit App_010411 .doc (Rev. 1/11 ) Environmental Consulting and Design SEPTIC SYSTEM DESIGN T12N R4W SEC 9 W2 SW4 SW4 Municipality of Anchorage Development Services Department On Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, Alaska 99519 July 18, 2011 Subject: Septic System Installation Permit 6728 W. Dimond Blvd. Ladies and Gentlemen: I am writing to request a permit to upgrade the septic system for the above referenced property. The owners are building an addition to the existing house and existing septic system is not sized properly. The proposed system will serve a 5-bedroom single-family residence. Soil logs, design calculations, a site plan, design drawings and construction specifications are enclosed for your review. Design Calcs: No Groundwater observed to a depth of 17.5 feet below ground surface (6/28/2011) Soil Rating: From Testhole 6/15/2011 3.2 min/in = 1.2 gal per sq.ft/day No. of Bedrooms 5 Required Area per Bedroom: 150/1.2 =125 sq.ft. Total area required: 125 x 5 = 625 sqft System: The existing system consists of two single compartment concrete tanks in series. The tank volumes are 1350 gallons respectively. The baffles in each tank will be replaced. A new deep trench subsurface absorption field will be installed it will be 60 feet long and 2 feet wide and contain 7 feet (840 sq.ft, effective) of sewer rock. Soils: A test hole was excavated on June 15th, 2011. See the attached soil logs. Ground water was monitored for through June 28th, 2011. Ground water was not observed. The soils in the area are very consistent. I have submitted the soils log for WoodCliff S/D lot 2 which confirms that the soil classification and percolation rate does not change. The reserve field can be sized the same as the proposed field. 203 West 15th Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland~gci.net Surface Water: septic system. Environmental Consulting and Design I No surface waters were observed within one hundred feet of the proposed Topography: The lot slopes to the east at approximately 1-2%. Waivers: None required. The installation of this septic system will not prevent wells and septic systems from being installed on the adjacent lots. The proposed septic system will not change the general slope of the area. Ponding and/or concentration of surface runoff will not result from this installation. If you have any questions or concerns, please contact me at 279-3916. Sincerely, ! "lz~i:~ Spbrkland, P.E. Civil Engineer 203 West 15th Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland~gci.net LOT 3A LET ~0 -- N ,,-,_--,_-- $0 0 / / NOTE: THIS IS NOT A SURVEYED PLAT. WELL ~ SEPTIC LOCATIONS TAKEN FROM ON-SITE WATER AND WASTE WATER DEPARTI~ENT DOCUI~ENTATION. ALL LOCATIONS SHOWN ARE APPROXIMATE. 300 50 100 150 200 250 SCALE; 1' = i00 Fr, / / LOT ~ L~T S SPURKLAND ENGINEERING 203 W 15TH. AVENUE ANCH. AK. 99501 (907? 2~9-,~9~ IL T12N R4~ SEC 9 ~2 S~4 S~4 ROB RETHERFORD $7Z0 It'. D/MONO BLVD., ANCHORAGE, AK .FE,~OZ SEPTIC SYSTEM DESIGN DA TE: JUNE 28, 2011 ~HEET: ?/',.T GRID: Z3ZZ PERHIT # £SPlllOXX PIB # 011-271-01 T12NR41,,/sgl,/PSIg4S~,/4B1.BI,/5 N NOTE: THIS IS NOT A SURVEYED PLAT. WELL k SEPTIC LOCATIONS TAKEN FROM ON-SITE WATER AND WASTE I~ATER DEPARTMENT DOCUI~ENTATION. ALL LOCATIONS SHOWN ARE APPROXII~A TE. 25 0 25 50 75 100 125 SCALE: 1' = 50 FT. LOT B SPURKLAND ENGINEERING 205 Vi 15TH. AVENUE ANCH. AK. 99501 ('907) 279-,3916 T12N R4 ~ SEC 9 ~2 S~4 S~4 ROB RETHERFORD 6725 W. DIMOND BLVD., ANCHORAGE, AK 9950Z SEPTIC SYSTEM DESIGN DATE: JUNE 28, 2011 SHEET: 2/$ GRID: 2522 PERMIT # DSPlllOXX PID # 011-c°71-01 TlcONR4~sglgcoSI,/4SIg4D1,DW6 S~and~rd Trench: ~.5' Wide ~0' Lo~9 7' Sewer rock 4' Cover ND SCALE Si! t Borrier~ 7,0 £t o£ Septic Rock Effective Connect to Exisitng single compartment tanks ~C --o,~ Monitor Cleonou$s - / NO SCALE 803 W15th Ave Anchor~Qe AR 99501 879-3<:916 T12N R4F SEC 9 ~2 SF4 S~4 ROB RETHERFORD 6728 WEST DIMOND BLVD., ANCHORAGE, AK 99502 II SEPTIC SYSTEM DESIGN DATE: JUNE 88, 8011 SHEET, 5/3 GRID, 2322 PERMIT ~ OSPXXXXXX PARCEL ID // Ol 1-271-01 TI2NR4WS9W2SW4SW4D$.DWG Performed For: Legal Description: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www.ci.anchora.qe.ak.us (907) 343-7904 Soils Log - Percolation Test Slope Date Performed: Township, Range, Section: Site Plan 2- 3- 4- 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- 15- 16- 17- 18- 19- 20- COMMENTS WAS GROUND WATER ENCOUNTERED? s IF YES, AT WHAT DEPTH? '~' L O Depth to Water After p Monitoring? -- E Date: Reading Date Gross Time Net Time Depth to Water Net Drop ~15/i/ i0~05,~ 0 ,~;~ 'ti ~/z" 8 '/~_" ,~ IO:lS^~ I0 ~;~ t2~'' PERCOLATION RATE '~; Z. (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN _~' FT AND (? FT PERFORMED BY: .,~.,~ ~ ¢' ¢~ I CERTIFY THAT THIS TEST WAS. PERFORMED IN ACCORDANCE wnLH ALL STATE AND MUNICIPAL G--0T~ELiI~IES IN EFFECT ON THIS DATE. DATE: GRE TER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME /~, &'/-?. /~;~r;7/Zf~(~/~:Y~'F_} MAILING ADDRESS '~;'' ~ '~ ~;(~',-/-~)/-)4':'~'-~')//} PHONE LOCATION ~)//.) c~'/' }~//)///~/Y/~ LEGAL DESCRIPTION //~/YI~,,~'(~ SEPTIC TANK: ~:~";-~;Y~" ~'-,~ DISTANCE ,..~ FROM WELL ~/~ MANUFACTURER__ MATERIAL INSIDE LENGTH__ INSIDE WIDTH LIQUID DEPTH NUMBER OF COMPARTMENTS .LIQUID CAPACITY GALLONS. SEEPAGE PIT: [./ic) -, ['.~"1"~/~ D~F- NUMBER OF PItS / DIAMETER OR WIDTH / ~, LINING MATERIAL ~'~'~/~//~: / CRIB SIZE: DIAMETER BUILDING FOUNDATION~-'C~ NEAREST LOT L NE/~///~ . ADDITIONAL ABSORPTION /V~-~ ~/~ LENGTH /~, /DEPTH '~" ) DEPTH DISTANCE FROM: WELL ,~-(~'¢:~' ~' TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA} //g/z/ SQ. FT. WELL: BUILDING FOUNDATION CESSPOOL APPROVED CONSTRUCTION NEAREST NEAREST LOT LINE SEWER LINE DEPTH DISTANCE FROM: SEPTIC ~_. SEEPAGE TANK ~'~! , SYSTEM ~/&~: ~/- OTHER SOURCES DISAPPROVED __ REMARKS DISTANCES: INSTALLED BY: ~/)h'//'/ PIPE MATERIAL: //~.~.~/,~ g_/-)~q7~ DIAGRAM Of SYSTEM LOT SLOPE: REMARKS: G.A.A.B. ~.;~ Form No, EQ-031 GreATEr ANCHORAGe AReA BOROUGH DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 'C" STREET ANCHORAGE, ALASKA 99503 TELEPHONE 274-4561 pER'liT NO. SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT INSTALLAT[ON LOCATION ~/L/'~ INSTALLATION OF: SEPTIC TANK TYPe AND SIZE OF FACILITY TO BE SERYED FINANCED THROUGH OTHER FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE TYPE SEEPAGE AREA SIZE MINIMUM DISTANCES, REQUIREMENT~ FOUNDATION TO SEPTIC TANK SEPTIC TANK , SEEPAGE pIT ~ -, DRAIN f}elD WELL TO SEPT]C TANK SEEPAGE PIT / CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. I CERTIFY THAT [ AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUG ORDINANCE NO, 28-68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. Z [