HomeMy WebLinkAboutUS SURVEY 3201 LT 23 T10N R1W SEC 23
EB Enterprises Fax : Nov 14 12:09
DEPARTMENT OF ~EAL.'TH AND HUMAN SERVICES -
ENVIRONMENTAL SERVICES DIVISION
P.O_ Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: ~'%ut ~ ~ ~(*~L¢'~ ~ PID Number; .~ -
~ .... ~. ~ ~ W~steweter S~sI~m; ~IN~ Upgrade
LEGAL DESCRIPTION. ~alrRating:l · ~ GPD/8,.F,.
SEPARATION DISTANCES ~Septic ~ Holdi,g lq 8.T.E.".
w~t~ . N/~ LIFT STATION .......
Remarks; BENCH MARK ....
Reviewed and approved by: Date'//-2 7~
11/14/95 13:45 TX/RX N0.0843 P.002 ·
Permit No.
On-$i[e
Legal Description:
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650' Anchorage, AK 99519-6650' Tel: 343-4744
Was[ewa[er Disposal System/Well Inspec[ion
LOT 23 U.S. SURVEY 3201 PID No.
Page of__
W.O. 95165
Date 10-26-95
Repot[
40.O'(A)
ASBUILT OF EXISTING TRENCH
SOLID MANIFOLD (W/CLEANOUT)
PIPE FROM SEPTIC TANK.
4" PERFORTATED PIPE
PERF DOWN LAID LEVEL
MONITORING TUBES
CAPPED - PERFORATED IN
SEWER ROCK, SOLID ABOVE.
PLAN VIEW .Ts
CLEANOUTS - CAPPED
(BOTIOM LEVEL)
SEWER ROCK
PROFILE (TYP)
NTS
EXISTING SYSTEM:
1. 1000 GALLON BAFFLED SEPTIC TANK.
100"
MONITOR TUBE CAPPED.
iD IN SEWER
ROCK, SOLID ABOVE.
BACKFILL
64"
PERFORATEO PIPE
LAID LEVEL ~TH
HOLES DOWN AND
36" CAPPED ON END.
I oP
TRENCH
MONITOR ~JBE
PERFORATED IN
ROCK. SOLID ABOVE.
CROSS SECTION
TRENCH A NTs
SENTEC Inc.
7801 E. 36TH AVE. Suite A.
Anchorage, Ak 99504
Ph: (907) 3334~881 Fax: (907) 333-1085
(E~ ENTERPF~ISE5
2. EXISTING SYSTEM WAS UNCOVERED AT THE TANK AND TRENCH.
THE UNDERLYING MATERIAL POORLY GRADED SILTY GRAVEL.
USE 1.2 GPD/SQ. FT.
5. 90' LONG BY 3' WIDE TRENCH W/ 36" OF GRAVEL.
4. TOTAL AVAILABLE ABSORPTION AREA: 540 SQ. FT.
DHHS REQUIREMENTS:
1. THREE (.3) BEDROOMS
2. WASTEWATER APPLICATION RATING: 1.2 GPD/SQ. FT
TOTAL ABSORPTION REQUIRED: 575 SQ. FT.
.3. REQUIREMENTS MEET: YES
DWN: ekb ~
CND: gmp
~;o gs
DATE:
E: AB NOTE
SENTEC Inc.
7801 E. 36TH AVE. Suite A.
Anchorage, Ak 99504
Co~75f. ru~;[o¢l 4 /~1~;~//1~r[t3~:~ Ph: (907) 333~881 Fax: (907) 333-1085
Department of Health and Human Services, Environmental Services Division
825 "L' Street, Room 502
Anchorage, AK 99501
RE: Lot 23 U.S. Survey 3201 Un-permitted on site services
October 30, 1995
The above mentioned lot improvements consist of a mobile home and on site services
consisting of a well and a septic system. DHHS has a well log on file but the septic system is
unpermitted. My client purchased this lot with the above mentioned on site services and he is
proposing to improve the lot by building a three bedroom home. In the process he is attempting to
conform to the DHHS on site services ordinances so that he may receive a land use permit for his
proposed improvements.
To verify the septic systems construction, the system was uncovered at two locations: at
the septic tank and near the end of the leach field. The enclosed asbuilt illustrates the conditions I
observed. The test pit near the end of the leach field was excavated to approximately 12 feet to
verify separation to ground water and to perform a perc test at the depth of the existing system,
approximately 6.0 feet. No ground water was encountered during excavation to a depth of 12
feet below. A monitoring tube installed and was checked on Oct. 2 and was dry.
In summary, the septic system consists of a baffled 1000 gallon tank (recently pumped) and
a deep trench leach field 90 feet in length underlain by 3.0 feet of sewer rock. A perc test was
performed on the poorly graded gravel with silt, at approx. 5.5 feet resulting in a perc rate of 2.5
minutes per inch (or 1.2 gpd/sq, ft). With an application rate of 1.2 gpd/sq ft the proposed
improvements will require approx. 375 square feet of absorption area. The existing system has
540 sq. feet of absorption area.
I conducted a septic adequacy test and a 4 hour well flow test and the results are enclosed.
In summary, the well produced 750 gallons within the 4 hour period. The leach field was dry prior
to the test and absorbed 450 gallons with in 90 minutes with a total change in depth of 12
inches. Both leach field monitoring tubes were monitored to ensure equal trench distribution.
If you have any questions, please do not hesitate to call. Thank you.
Sincerely,
Erin K Bashaw, Owner
I'111~ 2 Crow Creek tdw~to, t=.0o I~k~x 273, ~lrclwoocl, ~laet~ 09~,~7 l~n~/£ax 1-~7-7~3-2337
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 %" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
PERFORMED FOR:
LEGAL DESCRIPTION:
DATE PERFORMED:
Township, Range, Section:
1
2
3-
4-
5-
6-
7-
8-
9-
10-
11
13-
14-
15-
16-
17-
18-
19-
20-
SLOPE SITE PLAN
WAS GROUND WATER
ENCOUNTERED7
IF YES, AT WHAT
DEPTH?
Depth to Waler After
Moniloring? ~'~~ t3ate:
),} o
S
L
O
P
E
Gross Net Depth to Net
Reading Date Time Time Water Drop
~ ',00 ,. ~
~:o ~ 1,/~ ~ ~ ~ ~' e'
PERCOLATION RATE , (minutes/inch) PERC HOLE DIAMETER ~DIt
PERFORMED BY: I
TEST RUN BETWEFN 5 ~ FT AND ~'~ % FT
/
CERTIFY THAT THiS TEST WAS PERFORMED iN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
72-008 (Rev. 4185)
['l'jZEl'.,!II'qlJ[:'l [:,I:E;TFINCE E,[zI!IE-EEi'I FI !,,.l[!!:LL FII",I[:' l::lll',l:'r' .~ ,,".:,].IE '::EL'IIFI[:i[} ..... ":;'-'""'¥ -
[:' ~-' "~ ',,'~:'l"F I.:.IELL..: I]lR
JJ2}::Z~FEET FOR I=1 ri,: ...........
[[.~]Ci TC.I [~1:::1[:::1 F[!:[~TT I:=ROh'I 1:=I FlJE:L ZC I.,.IELL_ [:,EF:'ENE:,Iiq[E~ I.IF'ON THE 'I":T'PE OF P_.[:LI" [,.!El.L..
I,.I[ELL L.L 2.5 Fl[q:[~] RE(}!UIRE[:' FI["~[) h'IUL'~FF 8~ RE]'T.IRIq[~Z' T'.] TIqE [::EF'Ffl:;TTI'"IEI",IT I*[ITHIN B:3 ':
':'F:' 'T'HE I.,.IEI. Z_. COHF'LET:[ON.
CI'FHEI~: R[:~I]i[I.]][I:~::[~]f'I[.T.['"t'['(-}: I"tFI"~" FIPF'L.'*L :~F'EC]iF'IC!=IT]:CIN:E: F:II',I[:' CON::~:TRUC"FI()N [:: :[ I=I(]J[{U::[["['-:~:
FI":"FI ]: L.I::I[3[.E TCI I [.,IL:'~;I_![R:E PROF'EF: I N:Y['FIL. LFIT ]] 0I":1.
:[ ..I:[-.Fi[':' THFfF
J..: I FII'"I F'FIM-T. L. :1: FIR [,-! I 'l"l'~ ]"HE REI;!U ]: I:'~:EI'"IE[",I]".~; F'C[[;~: I.-.[i:.:[--:il; ]: '["E :SE[lllER'-:5 F:ff'.![:' b. IEL.I..']~;
FORTH F",' _ _
,=, 'THE l"1 i'.I'I"TF'FIL iT:'r' I]lF' FII:,ICHCI'r'~:FIGE.
"= ':" "::"' ='" ! f',l F:ICCOR[:,FINCE I.,J. I "['H THE ":r'~[:,E~!;.
' FIF'F'L ]: CI:II',,!T :E;T[~U'SFI
l,..,., ........
WELL OWNER ~Si~'~_.V~
~OOATION L t?~- ~..
WATER WELL LOG
FOSS DRILLING
1336 Ingra Street
MUNICIPALITY OF ANCHORAGE
f~'l DEPT OF HEALTH &
)/IRONMSNTAL p~OTF-CT ON
OCT ~ 1978
SIZE OF CA~ING ~"DEPTH OF HOLE ~FT. CASED TO ~ ~-~_
STATIC WATER LibEL 7/,,,FTo YIELD /0 GALoPERoMIN. WITH
FEET OF DRAWDOWN.
REMARKS
DATE COMPLETED ~ -c~ ~ ~ PUMP TO BE SET AT
LOT 11
LOT 22
LOT 2,3 ..r? ~ ®®
PROPOSED HOUSE LOC
F.F. = 100.0'
/
/
LOT 10
LOT 26
LOT 24
DAVE SIEFERT
with GLACIER VALLEY CONSTRUCTION
EXCLUSION NOIES: It is the owners' responsibility to determine
the existence of any easements, covenants, or restrictions
which do not appear on the recorded subdivision plat. NOTE: It
ts the contractor's responsibility to check top of foundation
grade and building setbacks in relation to IotJines and esm'ts.
LAND & CONSTRUCTION SURVEYORS-PLANNERS-ENGINEERS
440 WEST BENSON BLVD. # 105
ANCHORAGE, ALASKA 99503 (907) 562-5291
J(fax) 561-6626
SURVEY CERTIFICAHON: LANTECH has conducted a
physical survey of this property as shown on this
drawing and to the best of our knowledge end
abilities, oil dimensions have been measured true
PLOT PLAN OF: LEGAL DESCRIPTION:
LEGEND: SET FND
5/§"RD W/CAP~ 5/8" RB 0
3.25' ALMON.*MONU"EN[*I
!
OVERHA~G-
CONCRETE- I'~ . ' '1
LOT 25
U.S. SURVEY .3201
LOT 22
LOT 11
LOT 23
LOT 26
/
/
LOT 1 0
LOT 24-
:. Mark E. Davis ."
'... LS--7338,'"'
DAVE SIEFERT
with GLACIER VALLEY CONSTRUCIlON
LAND & CONSTRUCTION SURVEYORS-PLANNERS-ENGINEERS
440 WEST BENSON BLVD. # 105
ANCHORAGE, ALASKA 99505 (907) 562-5291
WORK ORDER NUMBER: NOV. 1, 1995 1"=60' fax) 561--6626
slono 95-24 ~'""~"'
4760
LEGEND: SET FND
EXCLUSION NOTES: It is the owners responsibility to determine
the existence o any easements, covenants, or restrictions E/8"BB W/CAP~) 5/8" RB
which do not appeor on the recorded subdivision plot. NOTE: It 3.25" AL.MON.~MONUMENf
is the contractor's responsibility to check top of foundotion RUB & TACK E3
LOT 23
U S. SURVEY 3201