HomeMy WebLinkAboutVALLI VUE ESTATES #1 BLK 1 LT 23
Municipality of Anchorage Page
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Name: ~ O~C~ CO ~ ~ N~ ~ Wastewater System: D New ~Upgrade
Address:
~ ~ ~L~ ABSORPTION FIELD
Phone: JNo. of B~ooms: ~eepTrench ~ Shallow Trench ~Bed ~Mound DOther
Soil R~ting: Total Depth from ori inal grade:
LEGAL DESCRIPTION C ~ ~ L~ ~P~.
Lot: Block: Subdivision: ~ ~ tO pipe bottom from o~.al grade: Gravel depth beneath pipe
Number of lines: IDistance between lines:
WELL: D New D Upgrade Gravel~:~/~ ~ Ft. )I ' Ft.
Classification (Private, A,B,C): Total Depth: Cased To: Total absorption area: Pipe material:
Ft. Ft. ~ SQ. Ft,
Oriller: Date Drilled: StaticWater Level: Installer: Date installed:
SEPARATION DISTANCES n Septic ~ Holding ~ S.T.E.P.
TO Septic Absorption Lift Holding Public/Pr[vat( Manufacturer: Capacityin gallons:
From Tank Field Station Ta~k Sewer Lines
Well ~/~ Material: Number of Compadments:
Surface
Water ~/~ LIFT STATION
Lot Size in gallons: ~ Manufacturer:
Line
I
Foundation ~ "Pump °n" level at: I"Pump °fl" level at: IH~gh water a'arm at:
CuHainDrain ~e ~ Pump Make & Model I Electrical Inspections pedormed by:
Remarks: BENCH MARK
Location and Description:
Inspections performed by:N. ;~ Dates: 1st --''____'
Department of Health an~ Human Services approval
Reviewed and approved by: ~ Date: 7- 7- ~
72-013 (1/91) MOA 25
~IVE£SIDN VAL
\ ~ EXISll CDNC~ETE PIT
\
\
I
TOBBEN SPURKLAND P.E,
~03 ~ 15TH, AVENUE
ANCH. AK. 9950!
LOT 2~, BLOCK 1 VALLI VIEW
SEC 14 [12N £3W
6756 BOUBLE T£EE COU£[
SEPTIC SYSTEM DESIGN
DATE~ JUNE ~ 1993
SHEET~Bt'/~ GRID, 2539
3' Wide
50' Lon0
]0' 2eep
5' Se~/er ~o~k
5' Cover
NO SCALE
INSTALL CLEANDUTS
DIVERTIQN VALVE
1250 go! Sepflc fonk
CLEAN AN1) CHECK £AFFLES
Cleonou~s
~ Corem
98, 7
TO CONCRETE PIT
Exi~$, 5Cound
Miro £i 140
o£ Septic Rock
ND SCALE 93
88, 9
TI?M; PORCH FDUNDA [IgN
ASSUMED ELEV, ]00,00 FT
TDBBEN SPURKL~N9 P,E,
203 W15~h ~ve
Anchorage Ak 99501
LET 23 BLOCK i VALLI VUE
SECTION 14 Ti2N R3W
6756 ]}DU£LE T£EE CDU£T
SEPTIC SYSTEM ASBUILT
D^TE, JUNE 2~ ]993
SHEET, 3/3 GRID, 2S39
PAGE 1 OF 1
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT
PERMIT NUMBER:SW920382
DESIGN ENGINEER:TOBBEN SPURKLAND, P.E.
OWNER NAME:BUTCHKO RONALD J
OWNER ADDRESS:3605 ARCTIC BLVD. APT 736
ANCHORAGE, ALASKA 99503-5704
DATE ISSUED:Il/12/92
EXPIRATION DATE:il/12/93
PARCEL ID:01531124
LEGAL DESCRIPTION: VALLI VUE ESTATES #1 BLK 1 L
T 23
LOT SIZE: 30827 (SQ. FT.)
NUMBER OF BEDROOMS: 4 THIS PERMIT: 4
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
2.
RECEIVED BY:
ISSUED BY:
ENGINEER WILL PROVIDE ADDITIONAL SOIL TEST AT TIME OF
INSTALLATION TO VERIFY CONSISTENCY OF SOIL AT RESERVE
SITE (INCREASE FROM 3 TO 4 BDRMS).
VERIFY INTEGRITY OF EXISTING SEPTIC TANK.
LOT
203 ~ ]Lth. Aw~e~ Suite 206
ANCHORAGE~ ALASKA 99501
(907) 279-5916
SEPTIC SYSTEM DESIGN
23 -BLOC~{ ~ V~LL~ VUE ?_~ ]
R0N BUTCHK0
STANDARD TRENCH
TOTAL LENGTH 50 FT.
TOTAL WIDTH 5 FT.
TOTAL DEPTH i0 FT.
ROCK DEPTH 5
COVER 5 FT.
PU~P AND CLEAN
EXISTING SEPTIC TANK
INSPECT BAFFLES
INSTALL DIVERSION VALVE TO
EXISTING CONCRETE RING PiT
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
PERFORMED FOR:
LEGAL DESCRIPTION: L~"~ _~
--. VA L.g.t
2
3 ,~ I ,L."T'
4
WAS GROUND WATER ~&~
ENCOUNTERED?
IF YES, AT WHAT
DEPTH? pO
E
"', ~ENG ,NEER:S SEA[)
Township, Range, Section:
5
6
7
8
9
10
11
12
13
14-
15-
16
17
18
19-
20-
Depth to Water A~r
Monitoring? ~:~ O,te:
Gross Net Depth to Net
Reading Date Time Time Water Drop
PERCOLATION RATE /'~'~ ~(minutes/inch) PERC HOLE DIAMETER ~ll
PERFORMED BY: ~ I CERTIFY THAT T S TEST WAS PERFORMED IN
72-008 (Rev. 4/85)
~ I o --'--'--~ -----. ..........
//
//I~ I ~ ,
I~ll ..~ ~:~ ' .
I' II ~ ·
Z
i/P/ALLEY
N
~0 100 1~0 ,200
£ChLE: 1' = lO0 Fr,
~58 30~
TUBBEN SPURKLAND P.E.
E09 W 15TN, AMENU£
ANCH, ~g, 99501
LOT 23, J~LOCK 1 VALLI VIEW
SEC 14 T12N RSW
6756 9DUBLE TREE C~IURT
SEPTIC SYSTEM DESIGN
DATE, OC~ 1~ 1998
SHEET, 1/3 GRID, 2539
SCALE; l' = 50
TDBBEN SPURKLAND P.E.
203 ~ 15TH. ~VENUE
ANCH, AK. 99501
LilT 23, BLI1CK 1 VALLI VIEW
SEC 14 T12N
6756 ~LTU~LE TNEE C£URT
SEPTIC SYSTEH ]DLSIGN
])ATE, On~[. ]5,
SHEET, 1/3 GRII), ,2539
I I
I I
I
I
I
I
N
£CALE; 1' = ~ FT,
TDBB£N SPURKLANB P,E,
203 ~ ~STH, AVENUE
ANCH, AK, 9950t
LOT ~3, ZLDCK 1 VALLI VIEW
SEC 14 [IBN R3W
6756 Z[IUZLE T~EE COURT
SEPTIC SYSTEM DESIGN
DATE, gcr, 15~ 1992
SHEET, 1/3 GRID, 2539
3' ~/ide
.50' Long
]0' B~ep
5' Sewer rock
5' Cover
NO SCALE
INSTALL CLEANOUTS
1
BIVERTION VALVE
]250 got Septic tenk
CLEAN ANB CHECK BAFFLE.
TO CONCRETE PIT
/ Cleanouts ---.
/~ Monltor
$* Cover / ~
5 £t o£ Septic Rock --//
NO SCALE
- Exis~. 6round
12.50 ga[, sep'~lc 3ank
TDBBEN SPURKLAND P,E,
803 W15th Ave
Anchorage Ak 99501
LDT 23 ~LOCK ] VALLI VUE
SECTIDN I4 TI2N R3~/
6756 BDU£LE T£EE CDURT
SEPTIC SYSTEM DESIGN
DATE, ~CT, £0 1992
SHEET, 3/3 GRID, £539
DIVERTER VALVE
Here's the simplest, strongest, and most economical diverter valve ever invented for septic tank leach fields.
It is made of tough molded plastic that will not shatter, bend, rust, or corrode. It is lighter in weight, easier
to handle and cut, and less expensive to ship.
FUNTIONAL
The diverter valve stem flow may be controlled
to individual or multiple fields (up to three) in
any combination. With a three way valve stem,
flow may be diverted to any two outlets. To
allow flow through all outlets the valve stem
may be removed from the assembly.
EASY TO INSTALL
· Connect 4" plastic sewer and drain pipe to
inlets and outl&ts on the four way distribution
box. (Unwanted outlets may be sealed by
installing outlet cap).
The Diverter shield which houses the diverter
stem may be cut to desired length.
DIVERTER VALVE
DEBCRIPTIOhl
PARTNO. PKG. QTY, MATERIAL LI~T PRICE
Diverter Valve
4" Diverler Valve.
4" DIverter Vslve
*IAPMO Listed
~75" 4 AES 83,50
~ 4 PV¢ 83.50
~i\ ;.'.'./:11'7
· .... ,,tQI'I .....
:[7-
'.._" ~a~n~) ~ou.voi-,o:~ds
] .... ..... .'"$PECiFICATION-GUIDE~,~
~ i. "' SlqlII,ii,VAIA~II DIVERI~ERVALVE '.
NOW AVAILABLE IN P.V.C,
IAPMO Lbtod
~NDS 675
NDe 575P
For septic tank leach fields, Irrigation and other applications
Here'a the etmpla~t, elrongeat, moat ooonomloal
dlverter valve ever Invented for aeptlo tank loach
fields and other epplloallone In drainage and Irrlga.
lion ayet~)me, Mede of tough AB$ molded plastlo
that will not shatter, bend, rust or ommda. Lighter In
weight. Eaaler to handle and out. Lees expensive to
~hlp,
With dlverter valve atom, you oan uontrol the Jndi.
vlduela end up to three outlete~ In any comblnatlen.
With a three.way valve t~t(~m, you divert flow to any
two outlets, To permit flow through ell outlets, JUet
fill the valve atom out of tho eeaambly.
To In~tall, co,naot standard 4" plaellc sewer and
drain couplings or regular reduoei' fittings to inlet
.nd gullets on the four.way dletrlbutor box.
(UnWanted gullets may be sealed by In~telllng outlet
oep.) Out dlverter shield to daglred depths and Install
In top alcove of distributor box. Insert dlverter valve
~tem. Cover with dlverler shield gap. ~
ANCHORAGE AREA BOr ,UGH
Department ~)~3E0n;irs~rner~;ntal Quality
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
LOCATIONO~'C~._L~-y ,/ _,~/,'¢)(~"-7~ ¢-~--~- LEGAL DESCRIPTION .Lg~ ]~/ ~/ U;~/~-!
SEPTIC TANK:
DISTANCE .r~ .... iA~,, ~-~ -"". -' /q ,'~ NUMBER OF
FROM WELL . MANUFACTURER~0''~ MATERIAL ,~ COMPARTMENTS
INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH ,.LIQUID CAPACITY ~'~'~ ~ O GALLONS.
SEEPAGE PIT:
NUMBER OF PItS I DIAMETER OR WIDTH
LINING MATERIAL CRIB SIZE: DIAMETER
BUILDING FOUNDATION , NEAREST LOT LINE
ADDITIONAL ABSORPTION
DEPT. t
DEPTHC~ I DISTANCE FROM, WELL~/V'V~ ,.
ABSORPTION AREA (WALL AREA) ~ SQ. FT.
WELL:
TYPE CONSTRUCTION
BUILDING NEAREST NEAREST
FOUNDATION_ LOT LINE SEWER LINE
CESSPOOL
OTHER SOURCES
APPROVED DISAPPROVED REMARKS
DEPTH DISTANCE FROM:
SEPTIC SEEPAGE
TANK SYSTEM
DISTANCES:
INSTALLED
PIPE MATE RIALC~)~
LOT SLOPE: ~""~., ,~ .
REMARKS:
Form No, LQ*031
DIAGRAM Of SYSTEM
:.., ~,~.~/,, ~, ~
GREATER ANCHORAGE AREA BOROUGH
DEPARTMENT OF ENVIRONMENTAL QUALITY
3330 'C" STREET ANCHORAGE~ ALASKA 99503
TELEPHONE 27Z~-4561
SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT
PERMIT NO..
'NS~^L"^T'ON LOCAT'O. (gh/*ll~y 'j..
INSTALLATION OF: SEPTIC TANK ~ SEEPAGE PIT
· OTHER
SOIL TEST RESULTS ~ '/~ ~-~) J~'/~)~/~) ,~/~'~ NOTE: THIS PERMIT I$ NOT VALID WITHOUT SOIL TEST
COMPLETION DATE ANTICIPATED
FINAL INSPECTION: 24 HOUR NOT~CE REQUIRED· BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION.
MINIMUM DISTANCES, REQUIREMENTS
FOUNDATION TO SEEPAGE PiT ~ ~ DRAIN FIELD //~ J
-. SEEPAGE PIT ~ DRAIN F[ELD~/~J/
WELL TO SEPTIC TANK /~g)' ~/~/ ~ SEEPAGE PIT /~)
DRAIN FIELD /~)/) ~ ALSO CONSIDER AREA WELLS.
~ /~
DRAIN FIELD /'~ /
SEPTIC TANK, / ~}~ SEEPAGE Pit -- /~/~ , DRAIN FleL~
~.,i~)/L.~ ~'~7- xt'~"7~ ///~/~ ~
DIAGRAM OF SYSTEM
CAST IRON INTO AND OUT OF SEPTIC TANK AND iNTO CRIB CROSSING GAP Of
EXCAVATION 5 FEETINTO UNDISTURBED SOIL.
4 INCH DIAMETER CAST IRON S~PHON PIPES ON SEPTIC TANK AND SEEPAGE PIT
FITTED W}TH AIRT~GHT REMOVABLE CAPS.
GRAVEL ~ACKIFILL
CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION.
I CERTIFY THAT [ AM FAMIL[AR WITH THE REC~U]REmENTS OF GREATER ANCHORAGE A~EA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE
DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE.
FORM NO. E~-Ol 6
~9~05~ ~'~D ~' '"'~
,, INN~ GR~/~TER ANCHORAGE AREA BOROUGH
~'5_1~{'~ 'DEPARTMENT OF ENVIRONMENT2L QUALITY
A~o~ou~" 3333 "C" Stree~
G~AI~ AN~~NM~N~AL QURLllY ANCHORAGE ALASKA 99503
Case
Performed For Smith Excavating Dated Performed oct, 5, 1973
Legal Descript.ion: Lot 23 BLOCK 1 Subdivision ,~al,Zey View ],states
This Form Reports Soils Log. ×x Percolation Test
Soil Test Must Be Logged To 4' Below Proposed Seepage System
Depth
Feet
2--
16'~
18~
Soil Characteristics
Brown Silty Sand (SM)
Gray Sandy Gragel (GW)
with silty sand pockets and seam~
Was Ground Water Encountered?
If Yes, At What Depth?
NO
Reading . Date ''. Gross Time :Net ~ime Depth to H20 .Net Drop
ation Rate Minute ~
Proposeu Install'ati'on: Seepage Pi: xx Drain Field
Decor of Inlet O.epth ~o Bottom Of Pit 6r Trench
COMMENTS: 120 sq. ft. of drainage'area is required per bedroom below fou~ feet depth~
Test Performed BY R.E. Carlisle Date Certified BY:
-. APPLIEr. 'NT FILLS OUT UPPER HAI/'~'~ONLY
Address Zip Code
Lending Institution /~(..AslcA t.) S/~ ~C. 9 ~C~,A,-. ~Z zT ZO, ~/~-a ~I I L) AI Phone
Zip Code
~ Multiple Famgy No. ot Bedrooms
[~ Public Utility
Sewer Disposal
'~ Individual Year Individual Installed: ~'~
[] Holding Tank
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
Time Time Time Time
Date Date Date Date
Inspector Inspector Inspector Inspector
.~ '~ - MUNICIPALITY OF ANCHORAGE
DEPT. OF H~ALTH
· ENVIRONMENTAL PRO~ECTION
SEP 2
RECEIVED
( '~APPROVED BEDBOOMS *GONDITIONB OF APPROVAL
( ) DISAPPROVED
()DATE CONDITION~t~I~21~L APPROVAL*~
Soils Rating Date Sewer Insta)led Well To Absorption Area Well Log Received
/ ~ ' ~ '~ Well to Tank Septic Tank Size
DATE RECEIVED
'- ~ . '~ INSPECTION APPOINTMENTS
T ME ITIME T ME
INSPECTOR INSPECTOR INSPECTOR
MUNICIPALITY OF ANCHORAGE ENVIRONMENTAl i';~O}ECTION
ENVIRONMENTAL SANITATION DIVISION
Telephone 264-4720 R E C ~ I V ~ D
REOUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES
5. LEGAL DESCRIPTION
STREET LOCATION'
S. TYPE OF RESIDENCE NUMBER OF~BEDROOMS
[] One [~ Four
[~ SINGLE FAMILY [] Two [] Five
[] MULTIPLE FAMILY [] Three [] Six
[] Other
7. WATER SUPPLY
[] INDIVIDUAL* * ATTACH WELL LOG. A well log is required for all wells drilled
'~ COMMUNITY since June 1975. For wells drilled prior to that date, give well
[] PUBLIC UTI LITY depth (attach log if available.)
8. SEWAGE DISPOSAL SYSTEM
'[~ INDIVIDUAL/ON-SITE** ,,~'"~ y YEAR ON-SITE SYSTEM WAS INSTALLED.
[] PUBLIC UTILITY /~
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REOUEBT BEFORE PROCESSING CAN BE INITIATED.
72-010 (Rev. 6/79)
THIS SIDE FOR OFFICIAL USE ONLY
1. TYPE OF RESIDENCE NUMBER OF BEDROOMS
[] SINGLE FAMILY [] ONE [] THREE [] FiVE [] OTHER
[] MULTIPLE FAMILY [] TWO [] FOUR [] SIX
PERMIT NUMBER
2. WATER SUPPLY
[] INDIVIDUAL DEPTH OF WELL
[] CQMMUNITY
DATE DRILLED
[] PUBLIC UTILITY
Connection Verified LOG RECEIVED
3, SEWAGE DISPOSAL SYSTEM PERMIT NUMBER
[]INDiViDUAL/ON -SITE DATE INSTALLED
[]PUBLIC UTILITY ~,~'~'~ ~
Connection Verified INSTALLER
[]Septic Tank or []Holding Tank
Size: If Tank is homemade SOILS RATING
give dimensions:
TYPE OF TANK MANUFACTURER
TOTAL ABSORPTION AREA MATERIAL
4, DISTANCESwELL TO: Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line
Absorption Area to nearest Lot Line
5. COMMENTS
~PPROVEDFOR ~ BEDROOMS
[] CONDITIONAL APPROVAL (letter must accompany certificate)
[~] DISAPPROVED
/
72-010 (Rev. 6/79)
ALASKA
I1UI Ollm nTAL CO[1T OL S RUIC S, I[1C.
~a~lin*¢rin§ 8 ~'nuironmenlal $1acJi~s MUNICIPALITY OF ANCHORAGE
DEPT. OF HEALTH &
ENVIRONMENTAL PROTECTION
OCT '7 1981
RECEIVED
lO/5/81
UNITED BANK OF ALASKA
P.O. BOX 7059
ANCHORAGE AK 99510
SELLER - WILLIAM ARTUS
SUBDIVISION-VALLEY VIEW
BLOCK-1
LOT-23
ADEQUACY TEST FOR SEWER SYSTEM
THE TYPE OF ABSORPTION SYSTEM IS A PIT WITH AN AREA OF 702 SQFT.
THE SYSTEM IS CAPABLE OF ACCEPTING 600 GALLONS OF WATER PER DAY.
THE SURGE CAPACITY OF THE SYSTEM IS 564 GALLONS.
BASED UPON THE TEST DATA THE SYSTEM IS ACCEPTABLE FOR A
4 BEDROOM HOME.
SEPTIC TANK ADEQUACY
THE EXISTING SEPTIC TANK VOLUME OF
THIS 4 BEDROOM HOUSE.
1250 IS ADEQUATE FOR
1220 JJ~¢st 25tJ~ Aucnu¢ - Anchoracl¢, Alaska 99503 · (907) 276-1361
825 'L'
ANCHQ[~AGE, Al ASKA 99501
(90~) 264~41 t 1
October 5, 1981
William Artus
629 L Street, Suite 20
Anchorage, Alaska 99501
Subject: Lot 23 Block 1 Valli Vue Estates Subdivision #1
Approval for the individual sewer and water facilities
cannot be granted until the following items have been
completed:
(1) The septic tank pumped with a receipt submitted to
this office for our review.
(2)
An adequacy test needs to be performed on the existing
leaching area. This test will determine if the system
is adequate according to National Standards. A listing
of private firms performing the test is enclosed. This
report needs to be submitted to this office for our
review.
If there are any further questions, please contact this
office at 264-4720.
Sincerely,
James S. Roberts
Associate Environmental Specialist
JSR/ljw
~c: United Bank Alaska
645 G. Street 99501
Linda Switzer
% Re/Max Properties
2702 Gambell Street
99503
GREATER ANCHORAGE AREA BOROUGH
Department of Environmental Quality
3330 "C" Street, Anchorage, Alaska 99503 274-4561
Date Received JuI¥
Time of Inspection
Date of Inspection
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER & WATER FACILITIES
FOR
Cony.
1. Approval requested by: First National Bank of Anchorage
Mailing Address: Post Office Box 4-2090, 99509 Phone: 274-1521
6, 1976
2. Property Owner: Harry Mc Clure Phone:
Mailing Address:
4.
5.
6.
Star Route A Box 32L 99507
279-9641
Legal Description: Lot 23 Block 1 Valli Vue Estates
Location: 6756 Double Tree Court
Type of facility to be inspected
Well Data: Co~ma~nity System
A. Type
C. Construction
Sewage Disposal System:
A. Installed 1974
Single Family
No. of bedrooms. 4
B. Depth
D. Bacterial Analysis
On-~ite
B. Installer
, Sewer Lines __
C. Septic Tank: 1. Size 2. Manufacturer
D. Seepage Pit: 1. Absorption Area 2. Material
E. Disposal Field: Total length of lines
Distances:
A. Well to: Septic tank , Absorption area
Nearest lot line , Other contamination
B. Foundation to septic tank ~, Absorption area
C. Absorption area to nearest lot line
EQ-034 (1/74) Page l'of two pages
page 2 of two pages - Req'~t for Approval of Individual
Water Facilities
~egal Description Lot 23 Block 1 Valli Vue Estates
Comments
ApprovedDisapproved Date
Approval Valid for one year from date signed
Greater Anchorage Ar~a Borough, Department of Environmental Quality
DIAGRAM OF SYSTEM
certify that the information contained in this request for approval to be a true and
accurate representation of the subject sewer and water facilities and these facilities
are operating satisfactorily.
SIGNED
Date
EQ-034 (1/74)
.;'-~MUNICIPALITY OF ANCHORAGF,
DEPT. OF HEALTH &
ENVIRONMENTAL PROTECTION
MUNICIPALITY OF ANCHORAGE
DEPAflTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
2510 East Tudor Road, Anchorage, Alaska 99504 276-2221
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER and WATER FACILITIES
JUL 6 1976
RECEIVED
1. Type of Inspection: CMRO VA
2. Property Owner: /-/(q,e~./ /~ ~/~'~
Mailing Address: .~c>/J~ J~o.~ ~2 (__ - ~?S'~ ~
FHA__ CONV /
Day Phone: ~2~'
3. Name of Buyer:
Mailing Address:
4. Name of Lending Institution: /
Mailing Address: ~/ ~c/. ~_~; /'~'~ .
5. Name of Realtor or Agent:
Mailing Address: ......
6. Legal Description: ,L- ~Y- ~
Location:
Day Phone:
Phone:
Phone:
7. Type of Facility to be Inspected: j~E_.<,
8. Water Supply
Type of Supply: Public Utility
No. Bdrms. Y
rtndividual.
If Individual, number of dwellings presently served
if Individual, depth of well
Sewage Disposal System
Type of System:
Public Utility
Individual (on-site) '~'~
If Individual, date of installation
72-003(3/76)
GREATER ANCHORAGE AREA BOROUGH
Department of Environmental Quality
3330 "C" Street, Anchorage, Alaska 99503 274-4561
Date Received 6/~1~74
Time of Inspection
Date of Inspection
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER & WATER FACILITIES
FOR
Cony.
1. Approval requested by:
Mailing Address:
2. Property Owner:
Mailing Address:
4.
5.
6.
Etrst National Bank
Box 4-2090 99509
Billy G. Wisdom
Phone: 274-0641
Phone:
Legal Description:
Lot 23, Block 1, Valli Vue Est.
Location:
Doubletree
Type of facility to be inspected single family
Well Data: Public Water
A. Type
C. Construction
Sewage Disposal System:
A. Installed 10/18/73
C. Septic Tank: 1. Size
D. Seepage Pit: 1. Absorption Area 702 sq.~t.
E. Disposal Field: Total length of lines
Distances:
A. Well to: Septic tank
Nearest lot line
B. Foundation to septic tank
No. of bedrooms
B. Depth
D. Bacterial Analysis
B. Installer Smit~
1250 gal. 2. Manufacturer Espinoza - concrete
2. Material rings
, Absorption area
, Other contamination
, Absorption area
Absorption area to nearest lot line
, Sewer Lines ,
EQ-034 (1/74) Page 1 of two pages
Page 2 of two pages - Request for Approval of Individual S~ ~r & Water Facilities
Legal Description
Lot 23, Block 1, Valli Vue Est.
Comments
Approved~ ~x~-~uDisapproved Date ~
Approval Valid for one year from date signed
Greater Anchorage Ar~a Borough, Department of Environmental Quality
DIAGRAM OF SYSTEM
certify that the information contained in this request for approval to be a true a.d
accurate representation of the subject sewer and water facilities and these facilities
are operating satis·factorily.
SIGNED
Date
EQ-034 (1/74)
3330
'GREATER ANCHORAGE ARL'.f~ BOROUGH ~'~,"r,o ~C'~o,~
'Department of Environmental Quality
"C St., Anchorage, Alaska 99503 - 274-4561
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER & WATER FACILITIES
1. Type of Inspection: CMRO VA FHA CONV
2. Prope'rty Owner: Billy G. W-isdom " ..;~".:
Mailing Addr 6 Double Tree ~ Day Phone 279-7571
3. Name Buyer: Mcdlur6%~r~f-r~ZAi.- '~ Sharon L. :,
Mailin§ Address: Day Phone 279-~641
4. Name of Lending Institution: The ~irst ~atlo'mal Bank of'Anchorage
Mailing Address: Box~-ZO9q99509) Phone 27~-1521
5.Name'of Realtor or Agent: Area Realtors
Mailing Address: 3300,,~,, Phone z?9-7571
Legal Description Lot 23, Blk. I, Valli Vue Estates
Location:
Type of Fac]]]~y to be ~nspec~ed. 3 No. Bdrms.-
~ater Supply
Type of Supply: Public U¢~IJty ×××× Znd~vidua]
If Individual, numBe~ of dwellings presently served
~f ~ndiv~du~l, depth of well
Sewa9e Disposal'System
Type.of S~stem: Public Utility __ Individual (on-site)
If ~ndividual, date o~ installatJon
xxxx