Loading...
HomeMy WebLinkAboutT15N R1W SEC 18 LT 30A MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP251328 Work Type: Septic Upgrade Tax Code Number: 05117135000 Site Legal Address: T15N R1 W SEC 18 LT 30A G:1155 Site Mailing Address: 19416 GANOE ST, Chugiak Owner: VANECK JAMES C Design Engineer: C & M Engineering This permit is for the construction of: Effective Date Expiration Date: Lot Size in Sq Ft: Total Bedrooms: 9/23/2025 9/23/2026 45618 Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: A test hole is required prior to construction of the absorption field, in the location shown on the site plan, to confirm minimum separation to impermeable soil and seasonal high groundwater. Construction may proceed at your own risk prior to 7-day groundwater monitoring. If results require a design change, construction shall stop pending approval of a change order. Please submit results with the inspection report (or change order, if required). 4 Received By: Ct Date: Issued By: LL, Date: /72,/-Z'C} ON -SITE SEPTIC/VVELL PERMIT APPLICATION Parcel I.D. 05117135000 Property owner(s) VANECK Mailing address Site address 19426 CANOE Legal description T1 5N R1 W SEC 18 LT 30A Number of Bedrooms 4 Engineering Firm C&M Engineering Building Permit Number Day phone Not Applicable ❑ APPLICATION IS FOR: APPLICATION IS AN: 0 all that apply) Disposal Field 0 Initial ❑ Septic Tank El Upgrade Holding Tank ❑ Renewal ❑ Privy ❑ Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Permit/Rush Fees: Date of Payment: Permit No. SP2 S- 13 2-SS WaiverFees: Date of Payment: Waiver No. Distance: May 2025 C&M ENGINEERING SERVICES Ph: 907-854-5558 Municipality of Anchorage Onsite Water & Wastewater Program 4700 Elmore Rd Anchorage, Ak 99507 RE: Proposed Septic System for T15N R1W SEC 18 LOT 30A Dear Reviewer, The above referenced property is currently served by an older undocumented system. We are requesting a permit to install a new 4-bedroom septic system. Our review of available documentation and field investigation show that this project will not adversely impact any nearby Wells, Wastewater disposal systems, replacement disposal sites, or drainage flowing onto and off of the subject property. As shown on the plan, the tank and field will be greater than 10’ from the house foundation. The tank will be of MOA approved construction. The tank and field shall be covered with a minimum of 2” moa approved insulation and 3’ of cover or a minimum of 4’ of cover without insulation. The design is based on the testhole logged by us in 2025. The testhole needs to be deepened to at least 14-feet at the start of construction to confirm that an impermeable layer does not exist to that depth. This approach is supported by historic testhole data: • A 1984 testhole logged by S&S engineering on this lot, revealed SM to a depth of 14-feet. • A 1984 testhole logged by S&S engineering on Lot 30 B revealed “sandy gravel” to a depth of 14- feet. • A 2015 teshole logged by Northrim on Lot 30 B revealed SM to a depth of 20-feet. • Two testholes were logged by Forge on Lot 32 in 2017, each revealing SM to depth of 16-feet. • None of the testholes referenced above indicated groundwater was present. Upon completion of the installation, a record drawing will be submitted showing the location of the new tank, leach field, well, and other applicable features. . Thank you for your time in reviewing this permit request. Please do not hesitate to contact me at 907-854- 5558 or by email cgbalzarini@gmail.com with any questions or concerns. Sincerely, Charles Balzarini, PE 9/15/25 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251328, Curtis Townsend, 09/23/25 Residence: T15N R1W SEC 18 LOT 30A number of bedrooms 4 br Water usage/bedroom 150 gpd/br Water Usage 600 gpd system type: Conventional type: trench Application Rate 0.8 gpd/sqft required absorption area 750 sqft width (W) 5.000 ft MIN gravel depth (D) 4 ft Min Required Length: 75.000 ft Groundwater Depth: dry Testhole Depth: 14 ft Max Excavation: SEE PLAN ft Calc By: CGB Date: 9/1/2025 C&M ENGINEERING SERVICES 907-854-5558 Septic Design Calculations RESIDENCE/LOT INFO DRAINFIELD REFER TO PLANS FOR DETAILS OF CONSTRUCTION Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251328, Curtis Townsend, 09/23/25 BUILDING 15'x15' SHED CHARLES G BALZARINI CE-13854REG IST EREDPROFE S S I O N A L E N GINEER 9/15/25 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251328, Curtis Townsend, 09/23/25 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251328, Curtis Townsend, 09/23/25 LEGEND EDGE OF GRAVEL DRIVEWAY DECK CONCRETE FENCE OVERHEAD UTILITIES POWER POLE RECORD DATA PER PLAT #77-18 SEPTIC PIPE WELL GUY WIRE 38.8' 16.7' 7. 0 ' 24.4'1. 7 ' 5.9'1. 7 ' 16.4' 31.8' 63.4' 6 7 .0 ' 2 5 . 9' 6 7 .0 ' 2 5 . 9' RESIDENCE BUILDING 15'x15' SHED TIMBERLINE SURVEYING AND MAPPING 17035 BARONOFF AVE EAGLE RIVER, AK 99577 907-242-5320 ryan@timberlinealaska.com FILE NO.: 25.157 SCALE: 1" = 30 FEET DATE: 7/9/2025 SHEET: 1 of 1 MOA GRID: NW1155 SCALE: 1" = 30 FEET(11"x17") 30'0' 60' AS-BUILT OF: ADDRESS: 19416 GANOE ST, CHUGIAK, AK LOCATED IN: ANCHORAGE RECORDING DISTRICT LOT 30ASECTION 18, T15N, R1W, S.M.PLAT #77-18 Ar chovage POt~.~cl 6 650 ANGt;ORA(}L, AL A,~KA 99502-(}6',50 (90/) 264 4111 DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION Permit II: 840453 January 31, 1985 TO: Permit Applicant SUBJECT: T15N R1W Section 18 Lot 30A A permit issued by this Department for an individual well and/or on-site sewer system has expired as of December 31, 1984. Permits are issued on a calendar year basis by authority of Municipal Ordinance. A new permit must be obtained from this Department for any well and/or on-site sewer system net installed by the expiration date. If you have drilled the well, a well log needs to be sent to this Department for documentation of the installation and to close the permit. If a private engineer inspected the installation of the on-site sewer system, the original as-built inspection report and the yellow copy must be sent to this office for review and approval, and for documentation. If there are any further questions, please call this office at 264-4720. Sincerely, Keith E. andt, SupeYvisor Environmental Engineering Program KEB/ljw enc: Copy of Permit SWP/057 PERMIT NO ~ DATE ISSUED: ON--S I TE 84045~? 0G~'1~, 04 MU~II ~IF -tLIT~' OF R~CHr ~F~GE DEPARTMENT 0~ HEALTH AND ENVIRONMENTAL F,.JTE[,TION /''- ' 8~5 L STREET..2~4-4~o~NCHORAGE' ~K ~501 ~ SEWER & [,~ELL F'ERH I T ~ APPLICANT: ADDRESS: C0NTRCT PHONE: JOSEPH LEMONE P.O. BOX RNCHORAGE, RK ~88-4413 LEGAL DESCRIP: LOT SIZE: MR~ BEDROOMS: SUBDIVISION: NA LOT: SECTION: 18 TOWNSHIP: i5N RANGE: 1N 5?750 (SQ. FT. OR ACRES> BLOCK: NR LISTED BELOW ARE THE OPTIONS AVAILABLE TO YOU IN DESIGNING YOUR SEPTIC SYSTEM. CHOOSE THE OPTION THAT BEST FI'TS YOUR SITE. TRENCH ' BlED DEPTH TO PIPE BOTTOM (FT.) 4. 0 GRAVEL DEPTH (FT.) ~. 0 0. 5 TOTAL DEPTH (FT.) 10. 0 4. 5 GRAVEL WIDTH (FT.) 2, 5 22. 0 GRAVEL LENGTH (FT. > 57. 0 44. O GRAVEL VOLUME (CU. ~'DS. ) ~4. 3 ~5. 8 TANK SIZE (GALS) l, 000. 8 ~m l.. SOIL RATING (SQ. FT. /BR) 225 [:,RR 4.0 7.5 7~. 5,$. 000, 225 · .'~ TANK MUST HAVE AT LEAST TWO COMPARTMENTS I CERTIFY THAT: 1. I AM FRMILIRR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS RS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE (MOA) AND THE STATE OF ALASKA. I WILL INSTALL THE SYSTEM IN RCCORDRNCE WITH ALL MOA CODES AND REGULATIONS, AND IN COMPLIANCE WiTH THE DESIGN CRITERIA OF THIS PERMIT. 3. I WILL ADHERE TO ALL MOR AND STATE OF RLRSKR REQUIREMENTS FOR THE SET BACK DISTANCES FROM ANY E~ISTING WELL~ NRSTENATER DISPOSAL SYSTEM OR PUBLIC SEWERAGE SYSTEM ON THIS OR ANY RDJRCENT OR NEARBY LOT. 4. I UNDERSTAND THAT THIS PERMIT IS VALID FOR R MAXIMUM OF ~ BEDROOMS AND ANY ENLARGEMENT MILL REQUIRE RN ADDITIONAL PERMIT. IF A LIFT STATION IS INSTALLED IN AN AREA COVERED BY NOR BUILDING CODES, THEN (i> RN ELECTRICAL PERMIT AND INSPECTION MUST BE OBTAINED} (2) RS-BUILTS HILL NOT BE APPROVED WITHOUT AN ELECTRICAL INSPECTION REPORT~ AND (~) THE ELECTRICRL,WOR~ MUST BE DONE BY R LICENSED, ELECTRICIAN. IssuE By DAT ............... MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND EHVl RONMENTAL PROTECTION 825 L, Street, Anchorage, Alaska 90S01 264-4720 SOILS LOG - PERCOLATION TEST SOILS LOG PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: 1 2 3- 4 5 6 7 8 9 10 11 12 13 14 -- 15 16 17, 18- 19- 20- COMMENTS "7-/~-^/ SLOPE SITE PLAN WAS GROUND WATER i~,] S ENCOUNTERED? ~, D ~ P IF YES, AT WHAT E DEPTH? Reading Date Gross Net Depth to Net Time 'rime Water Drop ~- //,'~-~ ~ ~;~,~ /~" ~z" PERCOLATION RATE TEST RUN BETWEEN '~ FT AND ~ FT (minutes/inch) DATE: