On -Site Wastewater Disposal System Permit
Permit Number: OSP251328
Work Type: Septic Upgrade
Tax Code Number: 05117135000
Site Legal Address: T15N R1 W SEC 18 LT 30A G:1155
Site Mailing Address: 19416 GANOE ST, Chugiak
Owner: VANECK JAMES C
Design Engineer: C & M Engineering
This permit is for the construction of:
Effective Date
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms:
9/23/2025
9/23/2026
45618
Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions: A test hole is required prior to construction of the absorption field, in the location shown on
the site plan, to confirm minimum separation to impermeable soil and seasonal high groundwater. Construction
may proceed at your own risk prior to 7-day groundwater monitoring. If results require a design change,
construction shall stop pending approval of a change order. Please submit results with the inspection report (or
change order, if required).
4
Received By: Ct Date:
Issued By: LL, Date: /72,/-Z'C}
ON -SITE SEPTIC/VVELL PERMIT APPLICATION
Parcel I.D. 05117135000
Property owner(s) VANECK
Mailing address
Site address 19426 CANOE
Legal description T1 5N R1 W SEC 18 LT 30A
Number of Bedrooms 4
Engineering Firm C&M Engineering
Building Permit Number
Day phone
Not Applicable ❑
APPLICATION IS FOR: APPLICATION IS AN:
0 all that apply)
Disposal Field
0 Initial ❑
Septic Tank
El Upgrade
Holding Tank
❑ Renewal ❑
Privy
❑
Well
❑
Water Storage
❑
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Permit/Rush Fees:
Date of Payment:
Permit No. SP2 S- 13 2-SS
WaiverFees:
Date of Payment:
Waiver No.
Distance:
May 2025
C&M ENGINEERING SERVICES
Ph: 907-854-5558
Municipality of Anchorage
Onsite Water & Wastewater Program
4700 Elmore Rd Anchorage, Ak 99507
RE: Proposed Septic System for T15N R1W SEC 18 LOT 30A
Dear Reviewer,
The above referenced property is currently served by an older undocumented system.
We are requesting a permit to install a new 4-bedroom septic system.
Our review of available documentation and field investigation show that this project will not adversely
impact any nearby Wells, Wastewater disposal systems, replacement disposal sites, or drainage flowing
onto and off of the subject property.
As shown on the plan, the tank and field will be greater than 10’ from the house foundation.
The tank will be of MOA approved construction.
The tank and field shall be covered with a minimum of 2” moa approved insulation and 3’ of cover or a
minimum of 4’ of cover without insulation.
The design is based on the testhole logged by us in 2025. The testhole needs to be deepened to at least
14-feet at the start of construction to confirm that an impermeable layer does not exist to that depth. This
approach is supported by historic testhole data:
• A 1984 testhole logged by S&S engineering on this lot, revealed SM to a depth of 14-feet.
• A 1984 testhole logged by S&S engineering on Lot 30 B revealed “sandy gravel” to a depth of 14-
feet.
• A 2015 teshole logged by Northrim on Lot 30 B revealed SM to a depth of 20-feet.
• Two testholes were logged by Forge on Lot 32 in 2017, each revealing SM to depth of 16-feet.
• None of the testholes referenced above indicated groundwater was present.
Upon completion of the installation, a record drawing will be submitted showing the location of the new
tank, leach field, well, and other applicable features.
.
Thank you for your time in reviewing this permit request. Please do not hesitate to contact me at 907-854-
5558 or by email cgbalzarini@gmail.com with any questions or concerns.
Sincerely,
Charles Balzarini, PE
9/15/25
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251328, Curtis Townsend, 09/23/25
Residence: T15N R1W SEC 18 LOT 30A
number of bedrooms 4 br
Water usage/bedroom 150 gpd/br
Water Usage 600 gpd
system type: Conventional
type: trench
Application Rate
0.8
gpd/sqft
required absorption area 750 sqft
width (W) 5.000 ft
MIN gravel depth (D) 4 ft
Min Required Length: 75.000 ft
Groundwater Depth: dry
Testhole Depth: 14 ft
Max Excavation: SEE PLAN ft
Calc By: CGB Date: 9/1/2025
C&M ENGINEERING SERVICES
907-854-5558
Septic Design Calculations
RESIDENCE/LOT INFO
DRAINFIELD
REFER TO PLANS FOR DETAILS OF CONSTRUCTION
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251328, Curtis Townsend, 09/23/25
BUILDING
15'x15'
SHED
CHARLES G BALZARINI
CE-13854REG
IST EREDPROFE S S I O N A L E N GINEER
9/15/25
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251328, Curtis Townsend, 09/23/25
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP251328, Curtis Townsend, 09/23/25
LEGEND
EDGE OF GRAVEL DRIVEWAY
DECK
CONCRETE
FENCE
OVERHEAD UTILITIES
POWER POLE
RECORD DATA PER PLAT #77-18
SEPTIC PIPE
WELL
GUY WIRE
38.8'
16.7'
7.
0
'
24.4'1.
7
'
5.9'1.
7
'
16.4'
31.8'
63.4'
6 7 .0 '
2
5
.
9'
6 7 .0 '
2
5
.
9'
RESIDENCE
BUILDING
15'x15'
SHED
TIMBERLINE SURVEYING AND MAPPING
17035 BARONOFF AVE
EAGLE RIVER, AK 99577
907-242-5320
ryan@timberlinealaska.com
FILE NO.: 25.157
SCALE: 1" = 30 FEET
DATE: 7/9/2025
SHEET: 1 of 1
MOA GRID: NW1155
SCALE: 1" = 30 FEET(11"x17")
30'0' 60'
AS-BUILT OF:
ADDRESS: 19416 GANOE ST, CHUGIAK, AK
LOCATED IN: ANCHORAGE RECORDING DISTRICT
LOT 30ASECTION 18, T15N, R1W, S.M.PLAT #77-18
Ar chovage
POt~.~cl 6 650
ANGt;ORA(}L, AL A,~KA 99502-(}6',50
(90/) 264 4111
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
Permit II: 840453
January 31, 1985
TO: Permit Applicant
SUBJECT: T15N R1W Section 18 Lot 30A
A permit issued by this Department for an individual well
and/or on-site sewer system has expired as of December 31,
1984.
Permits are issued on a calendar year basis by authority
of Municipal Ordinance. A new permit must be obtained from
this Department for any well and/or on-site sewer system net
installed by the expiration date.
If you have drilled the well, a well log needs to be sent
to this Department for documentation of the installation
and to close the permit.
If a private engineer inspected the installation of the
on-site sewer system, the original as-built inspection report
and the yellow copy must be sent to this office for review
and approval, and for documentation.
If there are any further questions, please call this office
at 264-4720.
Sincerely,
Keith E. andt, SupeYvisor
Environmental Engineering Program
KEB/ljw
enc: Copy of Permit
SWP/057
PERMIT NO ~
DATE ISSUED:
ON--S I TE
84045~?
0G~'1~, 04
MU~II ~IF -tLIT~' OF R~CHr ~F~GE
DEPARTMENT 0~ HEALTH AND ENVIRONMENTAL F,.JTE[,TION /''- '
8~5 L STREET..2~4-4~o~NCHORAGE' ~K ~501 ~
SEWER & [,~ELL F'ERH I T ~
APPLICANT:
ADDRESS:
C0NTRCT PHONE:
JOSEPH LEMONE
P.O. BOX
RNCHORAGE, RK
~88-4413
LEGAL DESCRIP:
LOT SIZE:
MR~ BEDROOMS:
SUBDIVISION: NA LOT:
SECTION: 18 TOWNSHIP: i5N RANGE: 1N
5?750 (SQ. FT. OR ACRES>
BLOCK: NR
LISTED BELOW ARE THE OPTIONS AVAILABLE TO YOU IN DESIGNING YOUR SEPTIC
SYSTEM. CHOOSE THE OPTION THAT BEST FI'TS YOUR SITE.
TRENCH ' BlED
DEPTH TO PIPE BOTTOM (FT.) 4. 0
GRAVEL DEPTH (FT.) ~. 0 0. 5
TOTAL DEPTH (FT.) 10. 0 4. 5
GRAVEL WIDTH (FT.) 2, 5 22. 0
GRAVEL LENGTH (FT. > 57. 0 44. O
GRAVEL VOLUME (CU. ~'DS. ) ~4. 3 ~5. 8
TANK SIZE (GALS) l, 000. 8 ~m l..
SOIL RATING (SQ. FT. /BR) 225
[:,RR
4.0
7.5
7~.
5,$.
000,
225
· .'~ TANK MUST HAVE AT LEAST TWO COMPARTMENTS
I CERTIFY THAT:
1. I AM FRMILIRR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS RS SET
FORTH BY THE MUNICIPALITY OF ANCHORAGE (MOA) AND THE STATE OF ALASKA.
I WILL INSTALL THE SYSTEM IN RCCORDRNCE WITH ALL MOA CODES AND REGULATIONS,
AND IN COMPLIANCE WiTH THE DESIGN CRITERIA OF THIS PERMIT.
3. I WILL ADHERE TO ALL MOR AND STATE OF RLRSKR REQUIREMENTS FOR THE SET BACK
DISTANCES FROM ANY E~ISTING WELL~ NRSTENATER DISPOSAL SYSTEM OR PUBLIC
SEWERAGE SYSTEM ON THIS OR ANY RDJRCENT OR NEARBY LOT.
4. I UNDERSTAND THAT THIS PERMIT IS VALID FOR R MAXIMUM OF ~ BEDROOMS AND
ANY ENLARGEMENT MILL REQUIRE RN ADDITIONAL PERMIT.
IF A LIFT STATION IS INSTALLED IN AN AREA COVERED BY NOR BUILDING CODES,
THEN (i> RN ELECTRICAL PERMIT AND INSPECTION MUST BE OBTAINED} (2) RS-BUILTS
HILL NOT BE APPROVED WITHOUT AN ELECTRICAL INSPECTION REPORT~ AND (~) THE
ELECTRICRL,WOR~ MUST BE DONE BY R LICENSED, ELECTRICIAN.
IssuE By DAT
...............
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND EHVl RONMENTAL PROTECTION
825 L, Street, Anchorage, Alaska 90S01 264-4720
SOILS LOG - PERCOLATION TEST
SOILS LOG
PERCOLATION
TEST
PERFORMED FOR:
LEGAL DESCRIPTION:
1
2
3-
4
5
6
7
8
9
10
11
12
13
14 --
15
16
17,
18-
19-
20-
COMMENTS
"7-/~-^/
SLOPE
SITE PLAN
WAS GROUND WATER i~,] S
ENCOUNTERED? ~, D ~
P
IF YES, AT WHAT E
DEPTH?
Reading Date Gross Net Depth to Net
Time 'rime Water Drop
~- //,'~-~ ~ ~;~,~ /~" ~z"
PERCOLATION RATE
TEST RUN BETWEEN '~ FT AND ~ FT
(minutes/inch)
DATE: