Loading...
HomeMy WebLinkAboutT15N R1W SEC 18 LT 30BT15N RIW Sec 18 Lot 30B #051-171-36 Municipality of Anchorage On-Site Water and Wastewater Program • (907) 343-7904 Page / of le ON-SITE WASTEWATER INSPECTION REPORT Permit Number: 0.5f Is/3 7/ PID Number: a 51 / 7/3 6" Dwelling Single Family(SF) ❑ Duplex(D) ❑ Multiple (SF and/or D) Project: ❑ New Upgrade Name: S i e-ve_Ar -OAis ABSORPTION FIELD Address ,Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound /9 573 ---.0Y ,s/V.. / ❑ Other Phone 8 / Number of Bed/rgoms Soil Rating Total depth from original grade 552^ 3 73 0 OGPD/SF /3, 5 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe 5 Subdivision Block Lot 3. Ft. /6t Ft. _ 30Filladded above original grade Gravel length Townshi13/SA( / q Range Section Ft. 78 Ft. /S/ ( 114/ / Gravel width Beds:Number of Lines Distance betwee\lines SEPARATION DISTANCES 3 Ft. _ \` fit. To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist.between trenches Tank Field Tank Line /staiog Fe 2- 2.5" Ft. \, Well `dd/4„ /0 (.#• Ufa - ^fie`TANK ?Septic 0 S.T.E.P. ❑Holding ❑Other \ ( ! (/ GJ Mann�ufactu?Septic [ G Capaci Surface Water ��yy�7 / — AAIL 17O(Z,4 ./-4ac �Q Gal. /l/t/ "f UQ Material Number of compartments Lot Line / 41* /0 /f -- -- NA 5— fie' z Foundation //1) /.f / 6 'r — — LIFT STATION NA /v Manufacturer Capacity Gal. Curtain Drain so .f �"(J f-' �- Pump on level at Pump off level at High water alarm at Remarks in. in. in. Pump make and model Electrical Inspections performed by PIPE MATERIAL House to tank A Tank to Installer LJ 3a3T drainfeld 363ci ct./At TS 7QNI_ Drainfield Q3(jj1( cum-411%1c( Inspector AK,,,,..,-4i21 �n BENCH MARK (Assumed elevation) /6 0 ft Inspection Location and description /� f� �+ dates: 1 tGA7/S 2nd /Z/Zi/.S ,� 00, 3IGL- 3'd /Z/zit S 4th /Z/sf/$" COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL En ° kt mp QF �?g 11 Conditional Approval: Date 41�'A. •^' A.,t,••,*4 it ® * :4�r _ - 0 `o6. / d' Steven W. Eng ; 'mss ��2p0. . .E/6/23,,t, .`, Approved in-4 t-_c4 /rl N ,� Date -2 ?-17 �,km�Oa Es Inspection Report_9-1-12.doc AS-BUILT MEASUREMENTS C D Lot 9 DC❑1 53 35.5 ST1 55 39 ` ST2 63 52.5 \\ / DC❑2 65.5 56 / 8 No CO/MT1 39 46 Conflicts CO2 60 45 MT2 60 45 CO3 10 32 C ass C Splitter 12 35 ell CD4 43 13 MT4 40 10 Lot 1 \v), 5% Slop ro o 1/ S ro� u�� ~ ��pP 0/MT2 cv— CO/MT1 0TH2 a0-- 1% _Slope C❑/MT4 oSplitter H Shafer (--/5— l Existing Field -- 1% Slope Ow Decommissioned /Ad Old�0 hed Above- Seotic Tanks Crib -O DCO2 round PER UPC -- ST2 I 41110# STNo New 2000 Gallon • DC1❑1 Conflicts Septic Tank / ,% Slope 6 Bairn d Lot 30-A Lot 2 -5- 00 Q Well RDA X100 ° 33' BLM 0' Utility Easement ROW J.y Avenue / lllllllllllllllll NORTHR/M :ter"` T15N R1W SECTION 18 1 40 ENGINEERING f* :49m LOT 30-B RECORD PO Box 770724 „;Ve aw LAY❑U T Engle River, Alaska 99577 . z- ' i WASTEWATER RECORD 907. 694. 7028 44 f If/. 7 'w UPGRADE SEPTIC 'tet°: �T: 5/20/17 12 of 3 w • Double Cleanouts Elevation @ 100' / Tank Cleanouts Elevation @ 98' Fin ade Opposing Cleanouts Between Septic Tank & Trench 2 Foot Cover /,e0 w/ 4° Insulation Elevation @ 97,5' "' / To Trench 2000Ga Steel levation @ 97, Elevation @ 97.4' Mounded Cover To Match Terrain 7 'Anchorage e Taankk Solid Pipe Monitor Tube leanout I G. O.G. Elevation @ 98.5' •-. Elevations For Both Trenches, Both Ends Filter Fabric 3. Elevation @ 95' - '' •,-..,>.;:;;' p s eipzWi�liP_.: t i i:•=•:•:•: 10' ' !-!•!•_= S❑ILS LOG - PERC❑LATI❑N TEST I\ICRTI--M Date Performed: 11/17/15 ENGINEERING Performed For: Chris Moore Legal Description: T15N 8114 Section 18 Lot 30-B DEPTH (FEET) T.H. Location: See Attached Design �/: 'a./,7 Organic Flat Terrain 1 - .0.• 3 _ ' . 5 - a:. SM Silty Sand Y• w/ Gravel 6 - •: Q:: :-. Groundwater? No 7 - Depth g _ v.-.0:1-• ` Water Depth 9 _ ;,• After Monitoring. None Date: 11/25 10 - .0.-:...:.:., _. Denser @ # Date Gross Tine Net Time Depth Net Drop 0 Depth 11 - .- - 1 11/17 0 -- 5' -- 12 - -•:•:.--,---. ..-"•t •,` 2 11/17 10 10 mil-. 7' 2' 13 - 3 11/17 12 -- 5' -- 14 - •``•.. 4 11/17 22 10 Hr. 7' 2' . • 15 - 5 11/17 25 -- 5' -- 16 - • 6 11/17 35 10 nir. 7' 2' 17 - 7 11/17 37 -- 5' -- 18 - • '... 8 11/17 47 10 nir. 7' 2' 19 - : : '• 9 11/17 50 -- 5' -- 20 - . • 1 10 11/17 60 10 nlr. 7' 2' 21 - Percolation Rate 5 min./inch Perc Hole Diameter 6' Test Run Between 3' and 4' Comments: Presoaked Performed By NarthRim Fng, I -�- CERTIFY THAT THIS TEST WAS Performed in Accordance with All State/Municipal Guidelines in Effect DN THIS DATE. DATE: 11/25/15 (°Fkt TESTH❑LE LOG NORTHRIMi; . ' ENGINEERING * •49m ' * LOT 30-B T. H. 2 PO Box 770724 Eagle River, Alaska 99377 a 907.694.7028 :OS° GE❑TECHNICAL m' tilIT:11/25/15 On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP151371 Tax Code Number: 05117136000 Work Type: Septic Upgrade Permit Effective Dates: November 16, 2015 to November 15, 2016 Design Engineer: NORTH RIM ENGINEERING Subdivision: T1 5N R1W SEC 18 Site Legal Address: T1 5N R1 W SEC 18 LT 30B G:1155 Owner/Address: JONES STEVEN 17806 MEADOW CREEK RD EAGLE RIVER AK 995770000 Site Mailing Address: 19513 JOY AVE, Chugiak This permit is for the construction of: Lot Size in Sq Ft: 45759 Total Bedrooms: 6 Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. The Engineer needs to do an additional test hole prior to the construction of the septic field. Construction may proceed at your own risk before the 7 day water monitoring is complete. Please submit stamped and signed results with the As -built Inspection Report. If the results require a design change, construction of the system will stop pending On -Site review and approval. Received By: a/m/- Ir IRWAUNICIPALITY OF ANCHORAGE Community Development Department " Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On-Site Water & Wastewater Program ON-SITE SEWERNVELL PERMIT APPLICATION I. s Parcel I.D. O V— 171- 3 4 Property owner(s) Day phone Mailing address 'T OK Ayt.= Site address Legal description (Sub'd., Block & Lot) Legal description (Township, Range & Section) !Z25nf SgC /,P 40/--3a — $ Lot Size S. 7S`3 Sq. Ft. Number of Bedrooms tir APPLICATION IS FOR: APPLICATION IS AN. TYPE OF DWELLING: (® all that apply) Absorption Field.' Initial ❑ Single Family (SF) Septic Tank Upgrade (w/wo ADU) Tank � Renewal ❑ Duplex (D) El Privy ❑ Multiple Dwellings ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. P6 owner Permit/RushFees: 61A -IMI go 911>4%Waiver Fees: Date of Payment: //I/�7'3� Date of Payment: Receipt Number: b5ll-) Receipt Number: Permit No. 0 P15 V31 1 Waiver No. Permit App_9-1-12.doc ENGINEERING Date: 11/9/15 To: MOA On -Site Services MEMO Steve Eng, PE, PH P.O. Box 770724, Eagle River AK 99577 (907) 694-7028 SteveEngPE@gmail.com Subject: T15N R1W Section 18 Lot 30-B Septic System Upgrade Number of Pages: An existing trench'has failed on the subject lot. A number of soil tests in the area reveal silty sandy gravel soil and no groundwater. The design calls for two 5' -wide trenches, and a new septic tank. A new soil test will be completed prior to construction to verify the soil. The entire subdivision is on wells and septic systems. The terrain slope is slight at the trench site. The system size is a single family at 6 bedrooms. A previous soil test is being used for design. It appears the existing trenches are beneath the shed. Please review the wastewater system design for the existing$' bedroom home. I have included design plans & specs, design guidelines, & soil tests. If there is need for additional information or clarification please give me a call. Thanks-Stev, , r THU - ENGINEERING T15N Rl W Section 18 Lot 30-B SPECIFICATIONS & DESIGN GUIDELINES Wastewater System Sizing: This is an existing 6 -bedroom, single family home. This is a developed subdivision. These lots are large and are served by private/Class C water wells. No adverse impacts are expected from trench/tank upgrade. No conflicts to the other lots will take place by this septic system construction. The easements are located on the drawing and are not encroached upon. A previous soil test reveals silty sandy gravel. A test hole will be completed prior to construction. An application rate of 0.6 GPD/FT1. Trench Length = 1500 FT2/10'x 2 = 75' trench, say 2 @ 38' (10' effective). A new 2000 gallon septic tank will be installed; Decommission old tanks/crib/field per UPC. Specification Requirements: All components and work must comply with the Municipality of Anchorage Specifications (AMC) & State of Alaska Drinking Water Regulations and Wastewater Regulations. • Two compartment, New 2000 gallon septic tank. Install Double Cleanouts. • 5' minimum between the tank and trenches. 10' to property lines. 3' of cover or insulation is required for trench; 2" Minimum thickness for insulation can substitute for 1' cover. Tank & solid pipe must be set on well compacted, stable soil. • 4 inch diameter cleanouts with airtight caps are required 1' to 4' from foundation wall, prior to any 90 degree bend in 4 inch line, in each tank compartment, and two adjacent opposing cleanouts between the tank and the absorption field, not more than 10' from the tank positioned to provide cleanout access towards the tank and towards the absorption field. • All cleanouts must extend to at least ground level. • In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron. Trench to be placed level, minimum of 4' to groundwater, 6' to bedrock from drain - rock. • Drain rock to be '/z inch to 2 %i inch screened. Drain rock to be distributed uniformly throughout the trench. • Perforated pipe to be installed level with perforations down. Silt barrier (filter fabric) to be installed above the drain rock. • Smeared trench sides must be raked or scarified before drain rock placement. • Backfill over drain rock must not be less than 36". • The finish grade must be mounded to promote drainage away from trench. • Insulation must be placed over any pipe installed under driveways or parking areas. • Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789, ABS ASTM D2661, • Sewer Service Line is minimum 2% slope. • Septic Tank to be pumped every two years or when required. • Insulation board to be extruded direct burial polystyrene (Dow Styrofoam HI/equal) DESIGN NOTES: 1. Total Depth of 2 Trenches is 13.5'. Lot 9 Terrain Slopes Slightly North & West. 2. Sewer Service Line minimum 2% slope. 3. Private Water Wells & Class C. 4. Decommission Old rench/Crib/Tanks Per UPC. No Cc 5. Test Hole Prior To Construction. 6. Measure Separation ihbStems. To NTito Prior To Constructi n. Lot 1 M l ` Z, 3- — \O%J Lr7 e 0i — CO'1. a— 1% Slope _O — �,5_-- 1 1% Slope Decommission M ❑ld Septic Tanks Crib 0 PER UPC Lot 2 Well NORTHRIM ENGINEERING PO Box 770724 Eagle River, Alaska 99577 907.694. 7028 New 2000 Gallo Septic Tank M Slope Shed ;s I Class C Well --R150 1 5% Slope _CO'TMT's Shafe TH No Confl Existing Field 6 ���til ILot 30-A o Y � _ 33' BLM Utility Easement ROW Avenue 'Aq T15N R1W SECTI❑N 18 LOT 30-B WASTEWATER DESIGN fI' UPGRADE SEPTIC 1" = 40' PLAN LAYOUT 11/16/15 2 of 3 PPI 4 (4mZ A V Z I Q Z o 0 = ° t T O Z von SITZ// �R1pj : Qi% 1 1 ON(A -P�W Nt-I A O Dro A* h-0-10 0ro A-00 T Sn S 3 CO rD )7 ro � (4 O 3 n N VlA W rD �'h(OQ T O 3 N A n — O Vl nhnro -9 90 -3 ro Q' � 0 r rroo V)3 O ro 3 S(0 - S Ln ro n- M L N ° -u O `+ 33 rrDD Ul T A 3 b7 �, ro it O W n 3 3 3 Q N� ro rD C d m p Z m Cn T 3 CD mn CD �O G) pT A A ° rD 3 T -9 m0 h A ^ n ° N M p A to m 3 rD .!� T l<o 77 rD fel Ln ro o F9 n h D R° O Q D = ° S w 0 m OT On 3 N fTl Z A < A n 0 d h rDro O < 3 -9 n M C £ m '�•'� F— CII h -5 ro m \ z A 3 CD l �7 A 3 ' al n s ° `rD0 .- (� 0 ^ 1 m h h ro T 3 O u I H O N i = Q 0h —r z T ro 3 G.S' W 3 Obi O 3- Uro N co h s ro T LA �+ W T A W (JI 3 p 0 O ut 3 n ro A 3 0 h N w r0 h ro ro ro 3 rD 1 h n A 3 R° T r0 3 n ro r0 N m O O 3 Q A h O 3 C) p A 3 O c h MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HFALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT ~PHONE I I~] NEW NO. OF BEDROOMS ~ Wi~Ltl~---- Liquid depth Dwelling PERMIT NO, Material Liquid capacity in gallons Type of crib DISTANCE TO: DISTANCE TO: Building foundation O'rHER PIPE MATERIALS SOl L TEST RATIN~ ~ ~ CHh depth Distance 15elc~ej~ lines/ inches" Tota/~.~ a~o/n area~ Total effective absorption area Nearest lot line Septic tank Absorption area(s) Distance to Jot line PERMIT NO. Building foundation Driller Sewer line DATE 72-013 (Rev. 3/78) MUNIcIPALIT? OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL' PROTECTION 825 L STREET~ ANCHORAGE~ AK ~9501 264-4?20 ON-----c. ITE -SELLER PERM I T PERMIT NO: DATE ISSUED: APPLICANT~ CONTACT PHONE: C/O S & S ENG~O. EAGLE RIVER, AK WILLIAM KNAPPE 99577 LEGAL DESCRIP; LOT SIZE: MAX BEDROOMS: SUBDIVISION: NA SECTION: 18 TOWNSHIP: 45759 (SQ. FT. OR ACRES) LOT: 30B BLOCK: NR iSN RRNGE: iW LISTED BELOW ARE THE OPTIONS AVAILABLE TO YOU IN DESIGNING WOUR SEPTIC $~STEM. CHOOSE THE OPTION THAT BEST FITS ~OUR SITE. TREt~CH BEE, DEPTH TO PIPE BOTTOM (FT.) 3.0 m~ 4.0 GRAVEL DEPTH (FT.) 7.0 0.5 TOTRL DEPTH (FT.) 10.0 4.5 GRRVEL WIDTH (FT.) 2.5 30.0 GRAVEL LENGTH (FT.) 82.0 ~ 60.0 GRAVEL VOLUME (CU. YDS. ) 56.9 66.6 TANK SIZE (GALS) i, 750.0 ~m i, 750:0 SOIL RATING (SQ. FT./BR) 18~ i~7 4.0 -?..5 7.5 5.0 750. 0 200 DEPTH TO PIPE BOTTOM < ~.5 FT. REQUIRES INSULATION DEPTH TO PIPE BOTTOM < 4.0 FT, MAY REQUIRE 8 LIFT STATION GRAVEL LENGTH > 75 FT. REQUIRES MULTIPLE RUNS (NOT E~CEEDING TANK MUST HAVE AT LEAST TWO COMPARTMENTS EACH) I CERTIF~ THAT: I AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET FORTH B~ THE MUNICIPRLITV OF ANCHORAGE (MOA) RND THE STATE OF ALASKA. 2. I WILL I,NSTALL THE S~STEM IN ACCORDANCE WITH ALL MOA CODES AND REGULATIONS~ AND IN COMPLIANCE WITH THE DESIGN CRITERIA OF THIS PERMIT. ~. I WILL ADHERE TO ALL MOA AND STATE OF ALASKA REQUIREMENTS FOR THE SET BACK DISTANCES FROM ANV'E~ISTING WELL~ WASTEWATER DISPOSAL S~STEM OR PUBLIC SEWERAGE S~STEM ON THZS OR ANV ADJACENT OR NEARBY LOT. 4. I UNDERSTAND THAT THIS PERMIT IS VALID FOR 8 MAXIMUM OF ~ BEDROOMS AND ANY ENLARGEMENT WILL REQUIRE 8N ADDITIONAL PERMIT. IF A LIFT STATION IS INSTALLED IN AN AREA COVERED BY MOA BUILDING CODES, THEN (l> AN ELECT~ PERMIT AND INSPECTION MUST BE OBTAINED~ (2> AS-BUILTS WILL NOT BE APP~VED ~ITHOUT AN ELECTRICAL INSPECTION REPORT.: 8ND (3> THE ELECTRICAL W~ MLI~T~~ 8 LICENSED ELECTRICIAN. RPPLI~RNT:~S & S ENG'G. NILLIR~ KNRPPE .... ..... MUNICIPALITY OF ANCHORAGE Protectio~/.~~7~/~ Department f Health and Environments __ 825 ~ Street,264-4720~ch°rage' A~.. 5p/~ * * * HANDWRITTEN PERMIT * * Permit ~ t WELL AND/OR ON-SITE SEWER PERMIT Legal Descr~ Lot Size: Type of Soil ~sorption System Is: Trench: ~ Drainfield: _ Seepage Bed: Holding Tank~ Maxim~ N~ber of Bedrooms: , ~ soil ~ating(sq.ft/br) The Required Size of the Soil ~sorption System Is: L~NGTH /~ / GRAVEL D~PTH ~ WIDTH The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(.in feet). There ~ ~o set width for trenches. The gravel depth is the minim~ depth mm tween the outfall pipe and the bottom of the excavation(iD ~ * * REQUIRED SE~ ~ GALLONS * * Permit applicant has th, .,~ ~,~. ] ~ department during the installation inspection~ .' ~/~ ~[J~ ~ ~ property and the number * * * ~ ~' 'D * * * ~ckfilling of any system ~ ~Fi approval by this departmen w~ll be subject to prosem /i/~ Minim~ distance between a ~ ~.~" .. C ~sposal system is 100 feet is 25 feet and to a co~uni , // ~ ~ f ~"~ tl logs are requ~rea Other requirements may apply ~ ~/~4~ ~/J ¢~.~uction diagrams are PERMI ....-~AES DECEMBER ~1~ 1 9 8 I certify that: (1) I ~ f~iliar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2) I will install the system in accordance with codes. n er,.n mor tZ , roo . (3) the residence is remodeled to sewer system may require enlargement AppliCant -~- / Date: ¢/¢~-- MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST [] SOILS LOG PERCOLATION TEST DATE PEREORMED: 6--/-- LEGAL DESCRIPTION: ~--o7' ~ ~ --,3" OAGf~q I~. 2 4 SLOPE SITE PLAN 10 11 12 13 14 15 16 17 18 2O COMMENTS WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? Reading Date Gross Net Depth to Net Time Time Water Drop , /~ PERCOLATION RATE /'~ (minutes/inch) TESTRUN BETWEEN ~'~Z- FTAND ~ FT 72-008 (6/79) CERTIFIED BY: DATE: PERMIT NO. MLI~I ICIr tLIT'~ L%mF FIY~(~I--f DEPARTMENT Or HEALTH AND ENVIRONMENTRL PROTECTION 825 ~L~ STREET, 8r.~:HORAGE, AK. 99501 264-4720 790008 ) APPLICANT LOCATION LEGAL WILLIAM G. KNRPPER KNAPPER LANE TiSN RiW Si8 L~OB PO BOX i57 CHUGIAK AK LOT SIZE 688 249:;L 45750 SQt.IRRE FEET MINIMUM DISTANCE BETWEEN 8 WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM · 00 FEET FOR A PRI¥ATE WEL. L.~ OR i50 TO 200 FEET FROM A PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WEt] WELL LOGS ARE REQUIRED AND MUST BE RETURNED TO TWE [~EPARTMENT WITHIN 30 DFIY'.:T'. OF' ]'HE WELL COMPLETION, OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS 8ND CONSTRUCTION DIAGRAMS I'qRE 8¥AIL~BLE TO INSURE PROPER INSTALLATION F'ERP11 T E~z.P I RES [)E£:Ef'IBER 3:1., ~l.S' l'-~ I FORTH BY THE MUNICIPALITY OF ANCHORAGE 2: I WILE. INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. -, I LINED: RPPLICANT WILLIAM ~3. /K~PPER CERTIFY THAT I 8M F~MILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS FINE:, WEL. E,.S FIS SET I)RII. IJI,4C,, IN ~. MUNICIPALITY OF ANCHORAGE DEPT. OF i ~ALTrl 8, ENVIRONMENTAL ,, i.CTiON MAR 2 7 k,/,:~ I)RIIJ,ING LOG Well Owner ~Zi : ~ ~ ~: ~?:: ..... ) 5;~L~ Location (address of: £oxv ~ship, Range, Section, if known; or distance mai~ road. Static water level ~'i ft. (abbve) Screen ( ); Perforated ( Describe screeh or perforation Well pumping test at ?_ gallons per (hour) of drawdown from static level. (below) land surface. Finish of well (check one) open end ( ; >, ); ). ilk ,',~ ,q ;r'c:,::t':,,,-- ~,,~ .0 , ,.,. " (minute) for . ;~ hours with )Date of completion ....... ~! / i //' 7 '4 WELL LOG Depth in feet from ground surface Give details of formations penetrated, size of material, color and hardness . A_ 'to_ ~ _ ' ' ' o 1 '1 _TO NWWA Certified Cnu ,¢.tor C{, ~f,c to NCs. 814 & ~'3 Municipality of Anchorage •• On-Site Water and Wastewater Program oH' t.� 1_ (907) 343-7904 K S c CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 051-171-36 Expiration Date: gr'2Z- —( 7 1. GENERAL INFORMATION Complete legal description T15N R1W Section 18 Lot 30B Location (site address) 19513 Joy Ave Current Property owner(s) Jones Day phone 552-3873 Mailing address Same Real Estate Agent Owner Day phone 552-3873 (01g919774., 2. TYPE OF DWELLING: r,,4 ROS ® Single Family (w/wo ADU) i .Lp\r '1 ❑ Duplex �i'�M ❑ Multiple Dwellings (Single Family and/or Duplex) �6 geti 3. NUMBER OF BEDROOMS: 6 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual Individual Water Storage ❑ Holding Tank ❑ Community Class C Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Received by: — Date: 2�J /7 COSA to be released to the engineer, unless otherwise r uested by the engineer. COSA Fee $ a(p$ Date: Date of Payment i it.oll/ Date of Payment Receipt Number OVii a5b Receipt Number COSA# 05C ll l`C l Waiver# • 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm NorthRim Engineering Phone 694-7028 Address PO Box 770724, Eagle River Engineer's Printed Name Steve Eng Date 5/15/2017 OF itt, • 6. DSD SIGNATURE ° '`-' . '" 1e'I System #1 Approved foryCstem #1 : ' 04, System #2 Approved for bedrooms. 70, ; Steven Eng Disapproved. 4,L A,�n PS 6 i 6 �, Zp $ ROFESSIS' r� Conditional approval for bedrooms, with the following stipulatio rt'a% N-'• \-\\' OF Aiilr: ON-SITE �u WATER AND r" o, WASTEWATER o PROGRAM `0•n, .rte By: { � Original Certificate Date: — r 7 The Municipality of Anchorage Devlopment Services Division(DSD)Issues Certificates of On-Site Systems Approval(COSA)based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska.The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet 9-1-12.doc If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certfficate of On-Siite Systems ApprovaD Checklist Legal Description: / /-!V t' k) f e G c Lel- 3013 Parcel ID:C51 ( 7136- A. (3A. WELL DATA Well type P If A, B, or C provide PWSID# Well Log (Y/N) y Date completed /0 7/7 ? Sanitary seal (YIN) r�/ Wires properly protected (Y/N) y Total depth 8' 3 ft. Cased to k0. 7ft. Casing height (above ground) 7di`/ in. FROM WELL LOG AT INSPECTION Date of test //i 7/7? S//al/7 Static water level 33 ft. P ft. Well production g.p.m. Z. Z g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 mL Nitrate 2. 75 mg/L Arsenic Nb ug/L Date of sample: .Shit 7 Collected by: /116r.-,, B. SEPTIC/HOLDING TANK DATA Tank Type/Material 5 e,r/C/ 5 7 Date installed /2f///5 Tank size 2000 gal. Ca c Number of Compartments Z Cleanouts (Y/N) Y/ Foundation cleanout(Y/N) Y Depression over tank (YIN) A./ High water alarm (YIN) /V A/e- Date of pumping Pumper C. ABSORPTION FIELD DATA Deep Date installed/272//.5 Soil rating (g.p.d./ft2 or ft2/bdrm) 0. 6. System type 1,rpric Length 3 k 'ei c{Cf ft. Width � ft. Gravel below pipe /d ft. Total depth /3,5 ft. Eff. absorption area/S60 ft2 Monitoring tube y' Depression over field N Date of adequacy test ��� Results (Pass/Fail) / For bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN & type) If yes, give date • D. LIFT STATION NA Date installed Size in gallons Manhole/Access (YIN) "Pump on" level at in. "Pump off" level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot / !i On adjacent lots /e70 rt- O Absorption field on lot /D Q /t On adjacent lots /4/(1 Public sewer main /&‘61,-- Public sewer manholelcleanout . / 1 'it 1 Sewer/septic service line 2 S '- Holding tank loD 1.t- Animal Animal containment areas SD -fr Manure/animal excrete storage areas ADO (i- SEPTIC/HOLDING TANK ON LOT TO: Building foundation /G {f Property line //e) <f Absorption fieldrf r7.- Water main /Q (fWater service line /d r f Surface water /OG rt r Wells on adjacent lots /Do f ABSORPTION FIELD ON LOT TO: ( Property line /o f Building foundation 7 _� t Water main / a 1- 1_4_ r Water Service line / Surface water /LW Driveway, parking/vehicle storage /Q " Curtain drain 5 D r" Wells on adjacent lots /r�[ /t' F. COMMENTS G. ENGINEER'S CERTIFICATION t ,,' . 4 O F + 1 certify that l have determined through field inspections and 4-- review of Municipal records that the above systems are in 0', : - conformance with MOA COSA guidelines in effect on this date. z;::;,,;_-w;� , Engineer's Printed Name - i_51Vs 0 , `�E �l ; Date sl/5// 7 0,. f ,r1 : 5/45/I 7 -3" 74 'iy%e4o4y— COSA yellow sheet_2-6-15.doc . LOT 10 LOT 9 S 89'59'06"E 150.00' — ' N y G LOT 30—B N LOT 1 45,759 s.f. o 0 0 a) / m . O Z Cr O b q SEPTIC PIPESa'- o cnX3.2' O 0 12.7'xt6.0' 203; )a LOT 30-A GREENHOUSES o ":„ N -z` N o0 4.0' PORCH�0' 1a.6 a:N \ 0 >GARAGE 8.7' l�SEPTIC PIPESS `� 363 �\ \ o WOODEN FENCE 2.2' CANT ` / �o� p 2.0'x60.2'�\ GRAVEL DRIVEWAY / ��, �� CANT a / 1 ,O ' 6°.2 .' N. \ LOT 2 `� o. 4s.a 50 c 7.8' / �'y `'A' . 516 2 •�Al'►r�� 2.0'x20.4' CANT QG, 2.0'x33.8' N• R 6° ` 1,2'x7.0' CANT CANT--_.r ' J 10' UTILITY EASEMENT lDECK WELL N /7-33' BLM RESERVATION rn —r- 1 v' N 89'59'24"W 150.00' KNAPPER LANE PLOT PLAN ___ AS BUILT _X SCALE 1" = 50' GRID NW 1 155 Project No. 17-103/R1 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Lang & Associates , inc . (907) 522-6476 Phone ooOOp (907) 522-4625 Fax �OF �/00�4 Professional Land Surveyors kenOlongsurvey.com d ,Q 1J jonathanOlangsurvey.com OO 0I hereby certify that I hove surveyed the following described property: QOM ' %LOT 30—B, SECTION 18, T15N, R1W, SEWARD MERIDIAN, ALASKA o *• 49TH*14---001, "'• *VOA Anchorage Recording District, Alaska, and that the improvements situated thereon are 0 VA within the property lines and do not encroach onto the property adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the surveyed �o� KENNETH LANN o premises and that there are no roadways, transmission lines or other visible O asements on said property except as indicated hereon. 00 sl, '•, 5.1,« L� .•' ,�0 t, 0Q *,''•.LS-5202.•'' S`�G Dated this the _ Day of ._ , , at Anchorage, Alaska aR •..... �0 c 4% O SSIONA1-�= It is the responsibility of the owner to determine the existence of any easements, 04000o -'` ' covenants, or restrictions which do not appear on the recorded subdivision plot. AECC963