ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP 19 1 a.ori PID Number: 051-172-38
Dwelling: ® Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New ® Upgrade
Name:
MYRTLE BEARDEN ABSORPTION FIELD - EXISTING
Address ❑ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound
18792 S BIRCHWOOD LOOP, CHUGIAK ❑ Other
Phone Number of Bedrooms Soil Rating Total depth from original grade
3 GPD/SF Ft.
LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe
Subdivision Block Lot Ft. Ft.
123 Fill added above original grade Gravel length
Township Range Section Ft. Ft.
15N 1 VV 18 Gravel width Beds:Number of Lines Distance between lines
SEPARATION DISTANCES Ft. Ft.
Total absorption area Number of trenches Dist. between trenches
To Septic Absorption Lift Station Holding Sewer p
From Tank Field Tank Line Ft2
-- -- Ft.
Well 69'+/- NA NA ' NA NA TANK El Septic ❑ S.T.E.P. ❑ Holding El Other
Manufacturer Capacity
Surface Water 100'+ NA NA NA PREMIER PLASTICS 1000 Gal.
Material Number of compartments
Lot Line 5'+ NA NA NA POLYETHYLENE 2
NA LIFT STATION
Foundation 10'+ NA NA NA
Manufacturer Capacity
Gal.
Curtain Drain NA NA ' NA NA
Pump on level at Pump off level at High water alarm at
Remarks Owner installed ST w/out permit 2003.
S.T. exposed and verified. in. in. in.
Pump make and model Electrical Inspections performed by
PIPE MATERIAL House to tank 3034 Tank to 3034
Installer Owner
drainfield
Drainfield CO/MT 3034
Inspector FWCS I MNA BENCH MARK (Assumed elevation) 100 ft
Inspection 1'' 5/2/19Location and description
dates: 2
3rd 4'' Bottom of Siding
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL -41:111°":‘
�‘At \
6.
Conditional Approval: Date /�' . . 4—
; *c.,•.)..• g TH i* .`..*
/ s'..!AI CHAEL N. ANDERSON:
'G, • No. CE 9489 /
1; 5/23/19 .. ���/
Approved CfictAB Date 10 3J19 • �o�sslo��'=�
* T►i � 8c e."4" Cl �..
Inspection Report_9-1-12.doc -h, WCul Ir.o.J-
w;o a r e'r • A .16;4131e Qt2.&4 .o l
W Kix\ b t z9 utio rit dam. to
MAWS
MUNICIPALITY OF ANCHORAGE
(; , 7t
Development Services Department ',\ `` Phone: 907-343-7904
On-Site Water & Wastewater Section Fax: 907-343-7997
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 051-172-38
Property owner(s) MYRTLE BEARDEN Day phone 9073519024
Mailing address 9300 BIORKA CIRCLE, EAGLE RIVER, AK 99577
Site address 18792 S BIRCHWOOD LOOP ROAD, CHUGIAK, AK 99567
Legal description (Sub'd., Block & Lot)
Legal description (Township, Range & Section) T15N R1W SEC 18 LOT 123
Lot Size 108900 Sq. Ft. Number of Bedrooms 3
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
(Z all that apply)
Absorption Field ] Initial n Single Family (SF) I?
(w/wo ADU)
Septic Tank Upgrade Duplex (D) ❑
Holding Tank ❑ Renewal ❑ —
Multiple Dwellings _
Privy ❑ (SF and/or D)
Private Well ❑
Water Storage ❑
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
WELL TO SEPTIC TANK Distance: 68'
certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
FWCS - Brent Western
(Signature of property owner or authorized agent)
Permit/Rush Fees: 1, / 30 Waiver Fees: a a.0
Date of Payment: S/Wl9' Date of Payment: 5/3i1/q
Receipt Number: Oa5300 Receipt Number: _ ag52d6
Permit No. d<JV/Q 1036-
Waiver No. 1 SP/Ql9,0'
G:\Development Services\Building SafetylOn Site Water and Wastewater\Forms\Client Forms\Perrnit Application.doc
PID: 051-172-38
N `9 ,,,
Ni
")diK. " WELL PREMIER PLASTIC
28.1 ' SEPTIC TANK
■
54.2' A
3BR v EXISTING PIT
N /
RESIDENCE ` C
• Co
68.9'
II— 54.2' :Mt CO CO SMT t
B
Lot
108,
0
m
r----
c)0
I
\ I
SCALE: 1' = 30'
co -\ IAT
co co
A-C=20.6' 8.88 98.85 NAL GRADE
B-C=14.7'
A-D=22.7' IN CFCO RAWL /-
B-D=17.9' SPACE ,
93.74 1,000-GALLON 93.49
PLASTIC TANK EXISTING SEEPAGE PIT
SEPTIC SECTION
SCALE: NTS
PREPARED FOR: SUPPORT SERVICES: _`\\\
MYRTLE BEARDON /?��. 4S %
T15N R1W SEC 18 LOT 123 i�. .i `Y 1A
* 49
18792 S BIRCHWOOD LOOP RD., CHUGIAK, AK ,
1,1144e414:4
Michael N. Anderson, P.E. DATE: 5/23/2019 /` •MaC�. CE. N. ANDERSON # /
No9489
4601 Natrone Ave. /DRAWN: FWCS 4 .5/23/19 "Air-
Anchorage, Alaska 99516 �, _
(907)727 8864/FAX: (907)345 1391 SCALE: 1" = 30' ‘�``.!-4111°-
Municipality of Anchorage ` e
^rhl_ur
P.O. Box 196650 • 4700 Elmore Road
Anchorage, Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997
http:/Iwww.muni.orq/Onsite
Development Services Department
On-Site Water and Wastewater Section
**** VARIANCE/WAIVER REVIEW ***
Waiver#: OSV191035 COSA#: OSC191165 Permit#: OSP191207
PID#: 051-172-38
Legal Description: T15N R1W Section 18 Lot 123
Engineer: Mike N. Anderson
Applicant: Myrtle Bearden
Your request for a waiver of the required 100 feet horizontal separation from the septic tank to
the private well has been approved. The approved separation distance is 68.0 feet. See engineer's
waiver request letter for justifications.
This waiver approval applies to the existing septic tank only. Any future upgrade to the on-site
wastewater disposal system will require all separation distances be met or another approval from
this department.
Waiver is Granted: X Waiver is not Granted:
Date: (0/3/19 Approved by: Ciuz -_2
/ Name of Reviewer
**** VARIANCE/WAIVER REVIEW ****
Michael N. Anderson, P.E.
Civil/Structural Engineering and Construction
4661 Natrona Ave. Anchorage,Alaska 99516
Phone 345-3377/Fax 345-1391
May 31,2019
Municipality of Anchorage
On-Site Water& Wastewater Program
P.O.Box 196650
Anchorage,AK 99519-6650
RE: T15N R 1 W SEC 18 LOT 123—WELL TO SEPTIC TANK WAIVER
Per previous discussions with MOA On-Site staff on the referenced non-permitted septic
tank that was installed in 2003 by the now-deceased owner, we respectfully request a
waiver of 68' from well to septic tank.
The well is up gradient and located on the opposite side and inside the house from the
tank. The nitrate sample results were ND. The plastic tank installed is a better tank than
the original steel tank that was allowed to be within 50' of the well at time of
construction. Water levels, the soil sorption and permeability of the area would indicate
low probability of any influence between the well and septic tank. Area well logs show
silty gravel and bedrock and test holes show slow percolating soils (20-40 min / inch).
Area nitrate results are also very low and mostly ND. Attached is a representative sample
of MOA record docs of the immediate area.
The existing well would be almost sure to be free from any form of sewage
contamination or influenced by the location of the septic tank. We do not expect there
to be any adverse effect on the subject or adjacent lots by the location of this existing
well and septic tank and request issuance of the waiver. Please contact Brent M.
Western or me if you have any questions.
Sincerely,
441144)(---
Michael N. Anderson,P.E.
tP( 4NS
MUNICIPALITY OF ANCHORAGE
Development Services Department \�\� � Phone: 907-343-7904
On-Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On-Site Systems Approval
Parcel I.D. 051-172-38 Expiration Date: R -
1. GENERAL INFORMATION
Complete legal description T15N R1W SEC 18 LOT 123
Location (site address) 18792 S BIRCHWOOD LOOP ROAD, CHUGIAK,AK 99567
Current property owner(s) MYRTLE M. BEARDEN Day phone
Mailing address 9300 BIORKA CIRCLE, EAGLE RIVER,AK 99577
Real estate agent Day phone
2. TYPE OF DWELLING:
® Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 3
4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Private Well ® Private Septic
Water Storage ❑ Holding Tank ❑
Community Well ❑ Community ❑
Public Water System ❑ Public Sewer ❑
Waiver request for: Distance:
Received by: Date:
COSA to be released to the engineer,unless otherwise requested by the engineer.
COSA Fee $ 55-6 Waiver Fee $
Date of Payment - 37/CM Date of Payment
Receipt Number 041r1-0 Receipt Number
COSA# 0509114•6- Waiver#
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater
disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in
effect at the time of installation. I acknowledge that On-Site staff may visit the site to verify the information submitted.
Name of Firm ANDERSON CONSTRUCTION&ENGINEERING Phone 345-3377
Address 4640 SHOSHONI DRIVE,ANCHORAGE,AK 99516
Engineer's Printed Name MICHAEL N. ANDERSON,PE Date 5/15/2019
SOF ..
j * '49 TR * A
6. DSD SIGNATURE I
System #1 Approved for bedrooms S. '.MICHAENo.L N. ANDERSON
44: /
CE
System #2 Approved for bedrooms 1,
Disapproved k SS1O
Conditional approval for bedrooms, with the following stipulations:
QIX j,TY OPArly��ii
ON-SITE 0 '
WATER I Np m
WASTEWATER
So
PROGRAM
By: � Original Certificate Date:
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA)based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA Checklist blue sheet
COSA Checklist
Legal Description: T15N R1W SEC 18 LOT 123 Parcel ID: 051-172-38600
If more than 1 septic system on lot: COSA Checklist# of_ Structure served by this system
A. WELL DATA
❑ Well log is filed with Onsite (or attached) Well production at time of test 1.4 gpm
Date drilled CIRCA 1968 Water storage tank volume NA gallons
`Total depth 112'+ ft Well disinfected for coliform test? ❑ Yes ® No
"Cased to 40+ ft ® Coliform bacteria is Negative
Z Sanitary seal is functioning correctly Nitrate mg/L ® Nitrate less than MRL (ND)
Z Wires are properly protected Arsenic ug/L Z Arsenic less than MRL (ND)
Casing height (above cement floor) 12+ in. Collected by FWCS
Date of flow test for COSA 5/2/2019 Date of Sample 5/3/2019
Static water level at beginning of test 37 ft.
Comments *Based on acoustic soundings. **Assumed based on area wells&water analysis.
B. TANK DATA—CIRCA 2003 - 1000-gal C. LIFT STATION - NA
Age of tank(s) 16 years ❑ Required maintenance completed
Tank type/material SEPTIC / PLASTIC Age of lift station years
Measured operating fluid level in septic tank 47.5" Lift station material
Z Standpipes/foundation cleanout per record drawing Comments:
Date of pumping 5/2/2019
D. ABSORPTION FIELD DATA— 12'L x 12'W x 6'ED 288SF SEEPAGE PIT
Which system tested (date installed) 8/21/1968 Adequacy test date 5/2/2019
® *ALL standpipes present per record drawing Results El Pass For 3 bedrooms
Total measured depth from grade 8_5 ft (max) Fluid depth prior to test 56 in
Measured depth to pipe invert from grade 5.75 ft(min) Water added 450 gal
❑ N/A—pressurized field New depth 66 in
❑ Monitor tubes go to bottom of effective. If not, state Elapsed time 1420 min
depth into effective 2.75'
® Code-required soil cover over field Final fluid depth 55 in
El System presoaked Absorption rate 450 gpd
(Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) N
date of test)
Gallons introduced gallons If yes, enter date
Comments/Deficiencies: *Appears so. System operating in the upper portion of the pit at 80-90% capacity&appears
to be nearing the end of its life—no guarantees how long it will continue to operate satisfactorily. Fluid levels include
the apparent 39" missing ED.
COSA Checklist.docx
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot> 100' Community Sewer Manhole/Cleanout> 100'
❑ Yes if No 69+/-ft ® Yes if No ft
Neighboring Tank > 100' ® Yes if No ft Private Sewer/Septic Line > 25' ® Yes if No ft
Absorption Field on Lot> 100' 0 Yes if No 98+/-ft Holding Tank> 100' ® Yes if No ft
Neighboring Absorption Fields > 100' Animal Containment> 50' ® Yes if No ft
® Yes if No ft
Manure/Animal Excreta Storage > 100'
Community Sewer Main > 75' ® Yes if No ft ® Yes if No ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10' ® Yes if No ft Wells on Adjacent Lots:
Property Line > 5' ® Yes if No ft Private Wells> 100' Z Yes if No ft
Absorption Field > 5' ® Yes if No ft
Water Main > 10' Z Yes if No ft
Community Wells > 200' ® Yes if No ft
Water Service Line > 10' ® Yes if No ft
If septic tank is under driveway comment below
Surface Water> 100' ® Yes if No ft
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10' ® Yes if No ft If absorption field is under driveway comment below
Property Line > 10' ® Yes if No ft Wells on Adjacent Lots:
Water Main > 10' ® Yes if No ft Private Wells > 100' ® Yes if No _ft
Water Service Line > 10' Z Yes if No__ ft Community Wells > 200' ® Yes if No ft
Surface Water> 100' Z Yes if No ft
F. ENGINEER'S COMMENTS
Septic tank separation of 70' requirement when originally installed. Owner installed Premier Plastic tank without
permit around 2003. Based on MOA record docs, Lang survey and observations—it appears the pit is 98'+/-to
the well.
,� OF ALS\
G. ENGINEER'S CERTIFICATION S 1
1 certify that I have determined through field inspections and review *"....4 9 TH k\ * I
of Municipal records that the above systems are in conformance
with MOA COSA guidelines in effect on this date. / . ./
MICHAEL N. ANDERSON.' r
�1 � No. CE 9489
/
W
COSA Checklist.docx 5'20-I9.. $ Al
SEWAGE DISPOSAL SYSTEM - APPLICATION § PERMIT
3'~ I?~~ ~ ~o ~ O ~-
Na~ of Applic~t,~Z ~. ~/~/ Mailing Add~ss~/r /~n/~/~ PA.
Residence Address~c4~/ /~ ~D, Location of Ins~alla~on~;~c$~~
...... Legal Descm~p~ion~d~ ~A3 3'~, /F ~. ;~ ~ ~i/~
Application to Install: Septic ~k ~ , Seepage p~t~, D~ain field__. , 0the~
To Serve ~he Following Facil~y~ ~ ~.~.,,
Financed Throush/$Nf /~F/~?~-~ To be Installed by, ~/~,f /3~=~d~7~
Percolation Tes~ Results_~ Anticipated Da~e of Comple~D
~,~. ......... BELOW TO BE FILLED O~ BY HEALTH DEPART~NT
This is to serve as
:.~as described below.
,a ~D%ic tank size
permit to ins%all a
Size of unit %0 be served
DISTANCES:
Health Autho~'ity
Type ..... Seepage Area_. _ Type__
DIAGRAM OF SYSTEM
I certify that I am familiar 'with the requirements of Greater Anchorage Area Borough
0 '
rdlnance No. 28-68 and that %be above described system is in accordance with said code.
INSPECTION REPORT, ON-SITE SEWAGE DISPOSAL SYSTEM
_SEPTIC TA~K: 0 ~ /--~ 7 Z- 57
Distance from well 70 Material.. 3/~x / Numbe~ of compartments / L~quid
capaaity, ,,/~ ~allons. Inside len~h, ~ Inside width Liquid depth
SEEPAGE SY,S~EM:
Seepage Pit: Nu~em of pits,,, / Outside d~amete%_ or width /~, len~h,, ~ ~
depth,,,~. , llninE material. ~.~[ . Distance f~om well/~', building ......
foundation, %~,9 .~ (wall
XILE DRAI~ FIELD:
Distance f~om well__, fomd~t~on .... , reelect lot line Total len~h
of lines Nu~e~ of lines Distance between l~nes T~ench w~dth in.
Total effective ~sorption amea ..... sq. ft. Len~h of each line
Depth: Top of tile ~o finish grade ..... Depth of filter material beneath
tile ,, inches. ~ove tile
WELL:
Type ~l~f~ Dist~ce fnom buildinE fo~dation~, nearest lot line/~0 ~,I neares~
sewe~ line ~ l, septic tank_ 7~ seepage system/~/; cesspool