Loading...
HomeMy WebLinkAboutT15N R1W SEC 18 LT 184 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 hftp://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP241080 Work Type: Septic Initial Tax Code Number: 05123228000 Site Legal Address: T1 5N R1 W SEC 18 LT 184 G:1054 Site Mailing Address: 18671 MINK CREEK DR, Chugiak Owner: CRUICKSHANK-FRIEND RVCBL TRUST Design Engineer: ARC TERRA CONSULTING INC This permit is for the construction of: Effective Date: Expiration Date: Lot Size in Sq Ft: Total Bedrooms: �r J DeI)artill ell t 5/14/2024 5/14/2025 113692 Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received -BY: U PJ fo Alc- / e rol Issued By: Date: Date: 3 MUNICIPALITY OF ANCHORAGE IJ Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 051-232-28 Property owner(s) Cruickshank -Friend RVCBL Trust Mailing address 18681 Mink Creek Dr. Chugiak, AK Site address 18671 Mink Creek Dr. Chugiak, AK Legal description (Sub'd., Block & Lot) Lot 184 Legal description (Township, Range & Section) T15N R1W Sec 18 Day phone Lot Size 113,692 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption FieldX❑ Initial ❑X Single Family (SF) X❑ Septic Tank X❑ Upgrade El(w/wo ADU) Holding Tank ElRenewal ElDuplex (D) El Privy ❑ Multiple Dwellings ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. Dea Duffus (Signature of property owner or authorized agent) Permit/Rush Fees: 5 Waiver Fees: Date of Payment: S� ZP "L Y Date of Payment: Receipt Number: Receipt Number: Permit No. USP 7i`� U�� Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc 20441 PTARMIGAN BLVD • EAGLE RIVER, AK 99577-8736 • PH (907) 868-3791 • FAX (907) 868-3793 ARCTERRA CONSULTING, INC 20441 Ptarmigan Bld, Eagle River, AK 99577 Office (907) 696-6111, Fax (907) 868-3793 May 13, 2024 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: New Septic System Permit –T15NR1W Sec 18 Lot 184 The owner has requested we proceed forward to obtain a new septic system permit for the subject lot. The proposed systems will serve a new 3-bedroom residence. The testhole was dug to a depth of 16’ on April 22, 2024, is attached; no groundwater was observed during the test nor after the 7-day monitoring period. We propose a 1000-gallon HDPE tank with a 32’ long by 2’ wide trench with 6’ effective depth, a total depth of 10’ maximum from original grade to serve a total of 3 bedrooms. The existing trailer on the lot will be repurposed as a storage shed and the existing septic system will be disconnected and abandoned in place once the new residence is built. The adjacent lots, with exception of the lot directly west and Lot 183A to the northeast, are developed and are served by private wells and septics. There is no surface water within 100' of the proposed tank and field. There are no wells within 200 feet of the proposed septic site except as shown on the system design. The new tank and field will be outside any protective well radii. We do not expect there to be any adverse effect on adjacent lots by the development of this tank and field. If you have any questions, please contact me at 696-6111/FAX 868-3793. Respectfully submitted, ArcTerra Consulting, Inc. Kenneth M. Duffus, P.E. Attachments: On-Site Sewer Application Wastewater Absorption System Details/Site Plan Soil Test Hole Log Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241080, Deb Wockenfuss, 05/14/24 A TRCERR A A TRCERR A C O NSULT I N G ,I N C . Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241080, Deb Wockenfuss, 05/14/24 I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. ARCTERRA CONSULTING, INC 20441 Ptarmigan, Eagle River,AK 99577 Office (907) 696-6111, Fax (907) 868-3793 SOILS PERCOLATION TEST Performed for: Date Performed: Project: TEST HOLE # TH Depth (Feet) 1- 2- 3 - 4- 5- Reading Date Gross Time Net Time Depth to Water Net Drop 6- 1 7- 2 8- 3 * 9- 4 10- 5 * 11- 6 12- 7 * 13 - 8 14- 9 * 15- 10 16- 11 * 17- 12 18- * Water Added 19- B.O.H. SEE ATTACHED SITE PLAN FOR HOLE LOCATION Was Ground water encountered? What depth? Depth to water after monitoring? Date (Depth below grade) Percolation Rate (min/in) Perc Hole Diameter ” Test Run Between ________ feet and _______ feet Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241080, Deb Wockenfuss, 05/14/24 PERMIT MUr~ I C I RL I T'~ OF t~lr4Ct-k ~RAGE DEPRRTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 ~L~ STREET~ ANCHORAGE, AK. 99501 264-4720 tdELL PERM I T 820872 ) APPLICANT -~ION PATRICI8 G FRIEND RTi BOX 2262 CHUGIAK 99567 26?-±365 MUST BE USED W?APPROVED SEPTIC SYSTEM Ti~~AtlA~ ............ LOT SIZE 999999 SQUARE FEET MINIMUM DISTANCE BETWEEN 8 WELL AND RNY ON-SITE SEWAGE DISPOSAL SYSTEM IS 100 PEET FOR 8 PRIVATE HELL OR 150 TO 200 FEET FROM 8 PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL. MINIMUM DISTANCE FROM A PRIVATE WELL TO 8 PRIVATE SEWER LINE IS 25 FEET 8ND TO A COMMUNITY SEHER LINE IS 75 FEET. WELL LOGS 8RE REQUIRED AND MUST BE RETURNED TO THE DEPARTMENT WITHIN 30 DAYS OF THE WELL COMPLETION. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS 8ND CONSTRUCTION DIAGRAMS ARE RVRILRBLE TO INSURE PROPER INSTALLATION. PER~I I T EXP I RES DECEMBER ~l, i982 I CERTIFY THAT l: I AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET FORTH B~HE MUNICIPALITY OF ANCHORAGE. ~ 2: I WI~L~NSTRLL THE SYSTEM IN RCCOR~NCE HIT~ THE CODES. SIGNED:-2-~I~-~-~------~-~ .... --~-1~--; APPLICANT PATRICI8 G FRIEND ISSUED BY - ~ ~,~~---DRTE ~ ~c~ V4. 0