Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
T15N R1W SEC 18 N2 SE4 SE4 SE4
A chorage POU 6-650 ANCH©RAGE, ALASKA 99502.-0650 (907) 264~4111 TONY KNOWLES, MA YOR DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION Permit ~: 840592 January 31, 1985 TO: Permit Applicant SUBJECT: Township: 15N Range:b~ Section: 18 A permit issued by this Department for an individual well and/or on-site sewer system has expired as of December 31, 1984. Permits are issued on a calendar year basis by authority of Municipal Ordinance. A new permit must be obtained from this Department for any well and/or on-site sewer system not installed by the expiration date. If you have drilled the well, a well log needs to be sent to this Department for documentation of the installation and to close the permit. If a private engineer inspected the installation of the on-site sewer system, the original as-built inspection report and the yellow copy must be sent to this office for review and approval~ and for documentation. If there are any further questions, please call this office at 264-4720. Sincerely, Keith E. Bandt, Supervisor Environmental Engineering Program KEB/ljw enc: Copy of Permit SWP/0 5 7 MUN I C I F'AL Ii TY OF= ,AN~2~'~DIF'-(A~.~E: DEPARTMENT OF HEAl_TH AND ENVIRONMENTAL PROTECTION 825 L STREET, ANCHORAGE, AK 99501 264-4720 ON---$ Z -rE: SE:WER & WE:LL. PrERIF'II I T PERMIT NO: 840592 DATE ISSUED: 07/18/84 APPL I CANT: ADDRESS: CGN'TACT PHONE AMERICAN ESG. %S&S ENGINEERING EAGLE RIVER, AK 6942979 99577 LEGAL DIESCRIP: StJBDIVIGION: NA I_OT: NA SECTION: 18 TGWNSHIP: 15N RANGE: 1W LOT SIZE: 1.25A (SQ.PT. OR ACRES) MAX BEDROOMS: 5 Listed below are the optiens available to you in des. igning your system. Choose the option that best fits your site. E~EED I¢~, DRA I fq DEPTH 'TO PIPE BOTTOM (FT.) 4.0 4.0 GRAVEl.. DEPTH (F'T.) O. 5 1.0 TOTAL DEPTH (FT.) 4.5 5.0 GRAVEL WII)TH (FT.) 27.0 5.0 ORAVEL LENGTH (FT.) 54.0 225.0 ** GRAVEL VOI_UME (CLI.YDS.) 54.0 61.9 TANK SIZE (GALS) 1.,0()0.0 ** 1,000.0 ** SOIL. RATING (SQ.. FT. /OR) 520 42]4 BLOCK: NA ~.~ep t i c .w-., GRAVEL LENGTH > 75 FT. REQUIRES MULTIPLE RUNS (NOT EXCEEDING 75 FT. ** TANK MuST HAVE AT LEAST TWO COMPARTIdENTS EACH) I certify that: 1. I am ¢amilia¢ with the reqLlirements for eh-site sewe.r,s and walls as far'th by the Municipality o¢ Anchorage (MOA) and the State o¢ Alaska. 2. I wiiI install the system in accordance with all MOA cedes and r~egulations, and in compliance with the design criteria ef th.is permit. 3.. I ~ill adhere to all MOA and State et' Alaska requiremen~ts for the :set. back distances from any existing well, wastewater disposal system er publ£c sewe~-age system on this or any adjacent o~' nearby let. 4. I understand that this permit is valid for a maximum o¢ 5 bedrooms and any enlargement will require an additional permit. IF A LIFT STATION IS INSTAL. LED IN AN AREA COVERED BY MOA BUILDING CODES~ THEN (1) AN ELE. CTRI~DC,].~ PERMIT AND INSPECTION ~UST BE OBTAINED~ (2) AS-BL~IL.'I'S WILl_ NOT BE APPR[~C~.D ~/I~T~THO[J~ AN ELECTRICAL INSPECTION REPORT~'AND (5) THE ELECTRICAl_ WORK~UST ~/~ BY A LICENSED ELECTRICIAN. ' ........... .......... ....................... [] SOILS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVl RONMENTAL PROTECTION 825 g Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: 1 2 F" ~ L..L_ 3 5 6 7 8 10 11 13- WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? DATE PERFORMED: /9 SITE /LAN '7 14- 15- 16- 17- 18- 19- 20- Gross Net Depth to Net Reading Date Time Time Water Drop COMMENTS 72-008 (6/79) PERCOLATION RATE ~/ (minutes/inch) TEST RUN BETWEEN ~L FT AND ~' FT