Loading...
HomeMy WebLinkAboutVALLI VUE ESTATES #2 BLK 1 LT 71Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 -SM S �� SU ON-SITE WASTEWATER INSPECTION REPORT AUG 111,2022 Permit Number: OSP221025 PID Number: 015-123-34 Dwelling: ® Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ® Upgrade Name JOANNA KARET ABSORPTION FIELD - EXISTING ❑ Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound Site Address 6820 ROUND TREE DR, ANCHORAGE ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 3 GPD/SF Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Ft. Gravel depth beneath pipe Ft. Subdivision Block Lot VALLI VUE ESTATES #2 1 71 Fill added above original grade Ft. Gravel length Ft. Township Range Section Gravel width Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line Ft2 Ft. Well 200'+ -- 25'+ TANK ® Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer GREER Capacity 1000 Gal. Surface Water 100'+ -- Material HDPE Number of compartments 2 Lot Line 10'+ __ NA Foundation 10'+ __ LIFT STATION Manufacturer Capacity Gal. Remarks TANK INSTALLED PER MOA CODE & PERMIT A CO WAS ADDED AT START OF EXISTING FIELD. Alarm location Electrical installed by Installer NORTHERN EXCAVATION Tankto PIPE MATERIAL House to tank 3034 d ainfield 3034 Drainfield CO/MT 3034 Inspector FWC BENCH MARK (Assumed elevation) 100 ft Inspection 15` 6/6/2022 Z,,, 6/7/22 Location and description 3rd 4"' GARAGE SLAB ON-SITE WATER AND WASTEWATER SECTION APPROVAL ---OF At""1 Conditional Approval: Date • . ' • • Septic System Approved - pp "�'� Date Z'1.�.2 Curtis Huffman ' ��G' •. CE 128991 p gw ��O 8/4/22 • �� 111 PROFESSION,` Note: this approval does not include well permit requirements. tKev uoiuzi-iu/ PID: 015-123-34 PERMIT: OSP221025 A -C=38.4' B -C=15,0' A -D=42.9' B -D=14.4' A -E=45,3' B -E=14.5' A -F=48.8' B -F=14.9' PSS �A Il� 256 1000—GAL HDPE 63 o TANK W/ E 09, 30��� BM: GARAGE SLAB CONST."THAT THE ST TO RELD HAD 5'+ SEPARATION. do INSTALLED ADDITIONAL CO SEPTIC SECTION SCALE, NTS VALLI VUE ESTATES #2 131, L71 SUPPORTOSERVICE PREPARED FOR: JOANNA L KARET 6820 ROUND TREE DRIVE C ANCHORAGE, AK 99507 FIRST WATER CONSULTING DATE: 8/04/22 13030 SUES WAY SURVEY. JLS DRAWN: FWCS ANCHORAGE, AK 99516 SCALE: 1" = 30' 907-350-9566 FirstWaterAK®gmail.com OF ALS 9 TH rtis Huffman CE 128991 810412022e,,W "VOSEsstoV" AV LOT 72 / BLK 1 "0. 5F ;P, 0, 8 � 2 1' E• N6� 20 SN�a a. 1b2 LOT 71 PAVED BLK 1 Ocy h0� D/w SEPTICVENT 6 n� y fSTi h�,OO `s o,n Sss Z A MH 4 T S2 `ss�j• ,�N 3 LOT 70 �930,J BLK 1 F 12359 RF• ANCHORAGE RECORDING DISTRICT ALASKA AS -BUILT OF: VALLI VUE ESTATES UNIT No2 ©= FND 5/8" RE13AR LOT 71 BLOCK 1 PLAT 74-148 SURVEY CERTIFICATE: I, John L. Schuller, Have conducted a QF+' A� SUjZ V�� physical survey of this property as shown on this drawing and that the . • ' '�-� e" s� I improvements situated hereon are within the property lines and no �4 g��� yv enchroachments exist other than noted. Under no circumstance should. any information on this drawing be used for construction offences, � Uj structures, improvements; or for establishing boundary lines. . . . . rn n EXCLUSION NOTES: It is the owners responsibility to determine' .-'� the existence of any easements, covenants, or restrictions which '•JQHN L. SCHULLER,: 0 � 3� do not appear on the recorded subdivision plat. a t� LS -10408 i , ? J� 1831 Talkeetna Street WORK ORDER NUMBER: QA1E: SCAM- E-Mwu N �? JUNE ffir 61-=40' schuller0ak net � V �a ,� Anchorage, Alaska 99508 22-061 GRQ NUMBER Boat acs: ��rofessionot L4 (907) 227-1455 office SW2539 220230 (907) 274-4992 fax MUNICIPALITY OF ANCHORAGE F On -Site Water & Wastewater Program �rt PR Box 196650 4700 Elmore Road G r. } Anchorage, Alaska 99519-6650 Phone: (907)343-7804 Fax: (907)343.7997 ' hV:fAVWW.muni-orgfonsite t •r � 9k Cly0RF4 L't l't IT1L'n[ On -Site Wastewater Disposal System Permit Permit Number: OSP221025 Effective Date: 2/1112022 Work Type: SepticTank Upgrade Expiration Date: 2/11/2023 Tax Code Number: 01512334000 Site Legal Address: VALLI VUE ESTATES #2 BLK 1 LT 71 K G:2539 Site Mailing Address: 5820 ROUND TREE DR, Anchorage Owner: KARET JOANNA L Lot Size In Sq Ft: 20,266 Design Engineer: FIRST WATER CONSULTING Total Bedrooms: 3 This permit is for the construction of: ❑ Disposal Field d Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15-55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (1 SAAC72) and Drinking Water Regulations (ISAAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65- Provide notification by calling (907) 343-7904 (2417). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: "" Prior to installing the tank, locate the beginning of the field to ensure that the required tank to field separation is met. Received By: Issued By: 2112/22 Date: Date: 17 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 015-123-34 Property owner(s) JOANNA L KARET Day phone Mailing address 6820 ROUND TREE DRIVE, ANCHORAGE, AK 99507 Site address 6820 ROUND TREE DRIVE, ANCHORAGE, AK 99507 Legal description (Sub'd., Block & Lot) VALLI VUE EST. #2 131, L71 Legal description (Township, Range & Section) Lot Size 26,266 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: (® all that apply) Absorption Field ❑ Initial ❑ Septic Tank Q Upgrade; [X Holding Tank ❑ Renewal ❑ Privy ❑ Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: TYPE OF DWELLING: Single Family (SF) Q (w/wo ADU) Duplex (D) Multiple Dwellings ❑ (SF and/or D) Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. nature or property owner or autnorizea agent) Permit/Rush Fees: 2 2--t—) Waiver Fees: Date of Payment: 9 b'0 2 a Date of Payment: Receipt Number: I � a 31�1 Receipt Number: Permit No. C_L2 p22102_6 Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc 13030 Sues Way, Anchorage, AK 99516 907-350-9566 / FirstWaterAK@gmail.com February 9, 2022 Municipalities of Anchorage On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 RE: SEPTIC TANK UPGRADE PERMIT LEGAL: VALLI VUE ESTATES #2 BLOCK 1, LOT 71 The owner has requested that we obtain a septic permit to upgrade the existing aged steel septic tank on the above referenced lot. We propose to install a 1000-gallon HDPE tank per the attached design to serve the existing 3-bedroom residence. The lot and area are served by a community well. The design will not impact any of the neighboring properties. Please contact us if you have any questions. Sincerely, Curtis Huffman, P.E. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221025, Deb Wockenfuss, 02/14/22 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221025, Deb Wockenfuss, 02/14/22 Municipality of Anchorage Page I of 2. DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: ,~'~,~/ ~Z~O070 PlDNumber:~Ol-5~'12~3~ Name:Wastewater System: D New D Upgrade TO~D W~GHT~N Address: ABSORPTION FIELD EXISTING ~2o ~o~b TREE IN° °fBedr°°ms: ~__ ~ Phone: ~'3~0 3 rench ~ Shallow Trench ~Bed ~Mound LEGAL DESCRIPTION sod Rating: ~ GPD/Sq. Ft. Total Depth f~grade: Lot: Block: Subdivision: )epth to pipe bogota from orig~e: Gravel th beneath pipe J J Fill added above original grade: : Township:~ N Range: ~ W ~ Ft WELL:coMH'u~,~e~ S' ST&upgrade ~raveJwidth/ Ft. 'umber°fli~ebetweenlineFst:. Classification (Private, A,B,C): Total Depth: Cased To: ~ption ar~a: Pipe material: Ft. CAR 5 Yield:GPM IPuapsetat: Ft JCasingHeighlAboveGround:Ft TANK REAAC~IT o~' SEPARATION DISTANCES ~s~ptio o Holding g S.T.E.P. TO Septic Absorption Lift Holding ~ubJic/prJvate Manufacturer: Capacity in gaHoRs: Material: Number of Compartments: Surface Water ~/00'- ~/OO ~ ~ >JO0I- LIFT STATION Lot Size in gallons: ~ Manufacturer: I Curtain Pump Make & Model J Eloclrical Inspections performed by: Drain Remarks: ~¢ ~g~ ~¢ ~ ~ in¢ ~lJ~ t'n BENCH MARK Location and Description: II Inspections performed by: ~L~TtOp %E6H %¢d% Dates: 1st Department of Health and Human Services approval %,~¢...,.~, . ~,.~,~ 72-0~3 (Rev 9/91) MOA 25 FRo~ ' A 8 -FO SEPTIC T4 NK c.o'.s C D Sub? EX~$'I'ING ,$ BDRM~ bev Iooc~ GAL S~:PTIC TAHK PLAN VIEW I t, tLET /~ ~L~W%.6' HEM 1ooo SEPTIC ~B.M, gAB GARAGE" ~ EL~ V. ': too INSuLATIO~ OV~ ( OUTL. FT PORTION OF I OuTLET iNveRT PRo FI LIE VERTICAL $CAL~ LoT "11) BLK I., VALLI VVE EST. SEPTIC T~NK REF'L,~-cEMENT PLAN ANb PRoF1LE ALL LoCATioNS ARE ..~PpRoX~MA-TE. J PAGE 1 OF 1 MUNICIPALITY OF ANCHOP~AGE DEPARTMENT OF HEALTH AND HI/MAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGPJ~DE) PERMIT PERMIT NL!MBER:SW940070 .DESIGN ENGINEER:FLATTOP TECHNICAL SERVICES OWNER NAME:WIGHTMAN TODD J OWNER ADDRESS:6820 ROUND TREE CIR ANCHORAGE, AK 99515 DATE ISSUED: 4/13/94 EXPIRATION DATE: 4/13/95 PARCEL ID:01512334 LEGAL DESCRIPTION: VALLI VUE ESTATES ~2 BLK 1 L T 71 LOT SIZE: 26266 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONTRUCTION OF: SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 ~ 15.65 AND THE STATE OF ALASKA WASTEWATER DIS~0SAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 OR 343-4681 AFTER BUSINESS HOURS 4. FRO~ OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: DATE: - ~ ~, DATE: LOT 72 LOT 71 BLOCK 1 TRENCH SUMP DRIVE 3BDRM HOUSE DOUBLE C.O. DOWNSTREAM OF NEW TANK / REPLACE EXISTING 1000 GALLON SEPTIC TANK WITH NEW 1000 GAL. SEPTIC TANK IN SAME LOCATION LOT 70 NOTE: LOTS IN THIS SUBDIVISION ARE ~- .~. SERVED BY A COMMUNITY WATER '~.-.. SYSTEM. NO WELLS ARE LOCATED ~.~.~(~. WITHIN 200 FEET. ~'~- ~O/, LOT 71, BLK. 1, VALLI VUE EST. #2 SEPTIC TANK REPLACEMENT SITE PLAN FLAT'TOP TECHNICAl. SEP..VICES 1 INCH = 40 FEET 14530 ECHO STREET DRAWN BY TFM ANCHORAGE, ALASKA 99516 APRIL, 1994 NOTE: THIS IS NOT A SURVEYED PLAT. ALL LOCATIONS SHOWN ARE APPROXIMATE. Flattop Technical Services 14530 Echo Street, Anchorage, AK99516 Phone (907) 345-1355 Lot 71~ Block 1~ Valli Vue Estates 6820 Round Tree Drive Septic Tank replacement Specifications 1.0 General: 1.1 The scope of the project consists of removal of an existing 1000 gallon steel septic tank and knstallation of a new 1000 gallon septic tank in the same location. 1.2 Construction shall be as depicted on the approved site plan. Minor deviations from these drawings may be allowed or required by the engineer conducting the inspections. All construction procedures and material specifications shall conform with Municipal and State requirements. All separation distm~ces shall be in conformance with Municipal requirements, unless specifically waived. 1.3 The contractor shall be responsible to obtain any necessary utility locates, and to work around any bm~ied utilities. 1.4 The conta'actor shall provide adequate cover material and rough grading over all system components to ensure that proper drainage is achieved after settlement and that there are no residual depressions. Insofar as possible the contractor shall minimize damage to ~ees and existing lawn areas. 1.5 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading after the soil is compacted, as well as placement of topsoil and reseeding ail areas distm'bed by the construction. 2.0 Septic Tank: 2.1 The existing septic tank must be properly abandoned by thoroughly pumping, removing, crushing and burial on site, or disposal at the landfill. 2.2 The new 1000 gallon, 2 compartment septic tank shall be Municipally approved and shall be set level on undisturbed soil. Each compartment shall be equipped with a watertight manhole cover and a 4" cleanout. If the tank is buried less than 4 feet, it shall be insulated with 2 inches of approved burial type, rigid insulation. 2.3 Ail pipe connections to the tank shall be equipped with waterproof mechanicaI couplings. The waste line fi'om the residence to the septic tank shall have a minimum slope of 1/4'" per foot, and the waste line between the tank and the soil absorption system shall have a nfinimum slope of 1/8" per foot. A cleanout shall be located withh~ 5 feet of the building foundation, and a double cleanout shall be installed within 5 feet downsWeam of the septic tank. 2.4 The contractor shall rake special care to ensure that the backfill soil under the inlet and outlet pipes is thoroughly compacted. 3.0 Inspection: 3.1 One engineering inspection will be required dnring the course of the project after the tank is set level and the piping connected, but prior to backfill. The installer shall coordinate the timing of the inspection with the engineer sufficiently far in advance to ensure the availability of the engineer. .. ANCHORAGE AREA BOR,.,,,>.. Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 LOCATION INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM ¢ MAILING ADDRESS SEPTIC TANK: DISTANCE FROM W E L g ~'7'¢"¢'r,'f-,~ INSIDE LENGTH MANUFACTURER ~ INSIDE WIDTH MATE RIAL,-~-~ NUMBER OF COMPARTMENTS LIQUID DEPTH LIQUID CAPACITY////~.~ _ GALLONS. TILE DRAIN FIELD: / TOTAL LENGTH DISTANCE FROM WELL ~¢'_-~'¢'1///[ FOUNDATION /c/~ NEAREST LOT LINE ~-~) * OF LINES NUMBER OF LINES / DISTANCE BETWEEN LINES ///f////~ TRENCH WIDTH ~'~'N. TOTAL EFFECTIVE ABSORPTION AREA 32~'~ SQ. FT. LENGTH OF EACH LINE ¢:/~ / DEPTH OF FILTER / DEPTH: TOP OF TILE TO FINISH GRADE /~ MATERIAL BENEATH TILE /~//-/~ '¢~ABOVE TILE g/'-/ IN. WELL: TYPE BUILDING FOUNDATION CESSPOOL APPROVED CONST RUCTION NEAREST NEAREST LOT LINE , SEWER LINE OTHER SOURCES DISAPPROVED REMARKS DEPTH SEPTIC SEEPAGE , TANK SYSTEM DISTANCE FROM: DISTANCES: DIAGRAM OF SYSTEM INSTALLED BY: PIPE MATERIAL: I' LOT SLOPE:_ GREATER ANCHORAGE AREA BOROUGH SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT PHONE SEEPAGE PIT //- ~ ~ LEGAL DESCRIPTION INSTALLATION OF: SEPTIC TANK TYPE AND SIZE Of FACILITY TO ]BE SERVED FINANCED THROUGH SOIL TEST RESULTS / 2'3~- , DRAIN FIELD ., OTHER NOTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST COMPLETION DATE ANTICIPATED FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEEPAGE AREA SIZE TYPE , DIAGRAM OF SYSTEM WELL TO SEPTIC TANK DRAIN FIELD WATER MAIN TO SEPTIC TANK DRAIN FIELD SEPTIC TANK, , SEEPAGE PIT TO RIVER, LAKE, STREAM. , SEEPAGE PIT ALSO CONSIDER AREA WELLS. ~ /0/ · SEEPAGE P~ DRAIN FIELD CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRib CROSSING GAP OF ~X~AVATION 5 FeET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PiT FITTED WITH AIRTIGHT REMOVABLE CAPS. CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. OR ] CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGEORAGE~REA BORO~CGH ORDINANCE NO. 28-68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. "~--'~' *~ 4~/~~'4~7~ ~'~ '~ '~ ~ ~&/~/~' DATE APPLICANT'S SIGNATURE . uREATER ANCtlORAGE AREA DOROUb,, Department of Environmell~al (/uality 333D "C" Street Anchorage, Alaska 99503 Performed for_ ...... Legal Description: This form reports: Soils log Depth Feet 2 - o~3 Fell SOII,S I,OG ' PEROI,ATION TEST Date Performed~- q--/~' Percolation test lO- ll ~ 12- 13- 14- Was ground water encountered? If yes, at what depth? / Reading Date Gross Time Net Time _lDepth to W~ter Net Drop Percolation rate minute. -Proposed installation: Seepage Pit ............. Drain Field Depth of Inlet . Depth to bottom of pit or trench EQ-040 (6/74) 1. GENERAL INFORMATION Complete legal description VALLI VUE ESTATES #2 BLOCK 1 LOT 71 Location (site address) 6820 ROUND TREE DRIVE ANCHORAGE AK 99507 Current property owner(s) REBECCA & WILLIAM ANDERSON Day phone Mailing address Real estate agent 1120 HUFFMAN ROAD STE. 24 ANCHORAGE AK 99515 3516 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4. TYPE OF WATER SUPPLY: Private Well Water Storage Community Well "A" Public Water System 3 Day phone TYPE OF WASTEWATER DISPOSAL: ❑ Private Septic ❑ Holding Tank ❑ ® Community ❑ ❑ Public Sewer ❑ Waiver request for: Distance:, Received by: COSA to be released to the engineer, unless otherwise requested by the engineer. Date: COSA Fee $ SSD -r2-?O Waiver Fee $ Date of Payment 3 2 Date of Payment Receipt Number. '3)'T / Receipt Number COSA # ©SC 2—Z t / k Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm FIRST WATER CONSULTING Phone 907-350-9566 Address 13030 SUES WAY, ANCHORAGE, AK 99516 Engineer's Printed Name CURTIS HUFFMAN, PE Date 8/5/2022 Comments: This investigation was completed in compliance with MOA guidelines, regulations, and best industry practices / methods. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year, quality of construction (workmanship & materials), the water usage of the family being served by the system and maintenance. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, any estimate of how long a system will function satisfactory for current or future occupants or guarantee that no unseen encroachments, deficiencies or discrepancies exist can be given by First Water Consulting & FWCS 6. DSD � SIGNATURE System #1 Approved for —Y bedrooms System #2 Approved for Disapproved Conditional approval for 67 P LC 4 bedrooms bedrooms, with the fol A/ u_u-i g'<P:• TM 9� *: 49 Curtis Huffman I • CE 128991 ROFESSI�N�'�'��A- stipulations: ..__� J,�� Original Certificate Date: 12 --IS r zZ The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other Legal Description: VALLI VUE ESTATES #2 BLOCK 1 LOT 71 Parcel ID: 015-123-34 If more than 1 septic system on lot: COSA Checklist # of A. WELL DATA - CLASS A WELL ❑ Well log is filed with Onsite (or attached) Date drilled Total depth _ft Cased to _ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) _in. Date of flow test for COSA Static water level at beginning of test _ft. Comments B. TANK DATA Age of tank(s) NEW TANK years Tank type/material SEPTIC / HDPE Measured operating fluid level in septic tank NEW ® Standpipes/foundation cleanout per record drawing Date of pumping NA — NEW TANK D. ABSORPTION FIELD DATA Which system tested (date installed)10/8/1975 ® ALL standpipes present per record drawing Total measured depth from grade *11.5 ft (max) Measured depth to pipe invert from grade *7=3 ft (min) ❑ N/A — pressurized field Structure served by this system Well production at time of test _gpm Water storage tank volume_ gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative Nitrate _mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by_ Date of Sample C. LIFT STATION ❑ Required maintenance completed Age of lift station _ years Lift station material Comments: Adequacy test date 2/4/2022 Results 2 Pass For 3 bedrooms Fluid depth prior to test 1 in Water added 450 gal New depth 5 in ® Monitor tubes go to bottom of effective. If not, state Elapsed time 180 min depth into effective *4.6 OF 4.5 MEASURED ® Code -required soil cover over field Final fluid depth 1 in ® System presoaked Absorption rate 450 gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) N date of test) If yes, enter date Gallons introduced gallons NE Comments/Deficiencies:.*RAW DATA AT GRADE MT/CO. MEASURED ELEVATION 4.5' ED AT 10/8/1975. E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' ® Yes if No ft Wells on Adjacent Lots: Community Sewer Manhole/Cleanout > 100' ❑ Yes if No ft ❑ Yes if No. Neighboring Tank > 100' ❑ Yes if No ft Private Sewer/Septic Line > 25' ❑ Yes if No Absorption Field on Lot > 100' ❑ Yes if No ft Holding Tank > 100' ❑ Yes if No Neighboring Absorption Fields > 100' Surface Water > 100' ® Yes Animal Containment > 50' ❑ Yes if No ❑ Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' F-1 Yes — if No ft C1 Yes if No From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ® Yes if No ft Surface Water > 100' ft ft ft ft ft ® Yes if No ft Property Line > 5 ® Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' ® Yes if No ft Private Wells >' 100 _ ®Yes if No . Water Main > 10' ® Yes if No ft Community Wells > 200' ® Yes if No Water Service Line > 10' ® Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ® Yes if No ft If absorption field is under driveway comment below Property Line > 10' ® Yes if No _ ft Wells on Adjacent Lots: Water Main > 10' ® Yes if No ft Private Wells >' 100 _ ®Yes if No _ ft Water Service Line > 10' ® Yes if No ft Community Wells > 200' ® Yes if No Surface Water > 100' ® Yes if No ft F. ENGINEER'S COMMENTS ADDITIONAL CO INSTALLED AT START OF EXISTING FIELD AT TANK CONSTRUCTION. G. ENGINEER'S CERTIFICATION l certify that / have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. -dewAmw AW �� l ,,,, g• TM . Curtis Huffman F' • CE 128991 8/5/22AW •.��� ®��..... ROFESS`0'-. N, ft li, • • GC 8C • Municipality of Anchorage0 On-Site Water and Wastewater Program ■ l (907) 343-7904 SAFETY Certificate of On-Site Systems Approval 1/ Parcel I.D. 015-123-34 Expiration Date: 7`2-I IT 1. GENERAL INFORMATION Complete legal description Valli Vue Estates #2 Block 1 Lot 71 Location (site address) 6820 Round Tree Drive Current Property owner(s) Matthew Ubedei & Nazly Mofidi Day phone Mailing address 8901 Sahalee Drive, Anchorage, AK 99507 Real Estate Agent Day phone 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Q Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System Cl Public Sewer ❑ WaiverNariance request for: Distance: Received by: // an,`hti e/ i Date: -://6VCOSA to be released to the engineer.unless otherwise requested by the engineer. COSA Fee $ Waiver Fee $ Date of Payment 1/a6/ (g Date of Payment Receipt Number 0 9 3 l 2_. Receipt Number COSA# i S( 1%1 -376 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Forge Engineering Phone (907) 522-7773 Address PO Box 240773 Anchorage, AK 99524 Engineer's Printed Name Benjamin Schiller, PE Date 7/30/18 �OF ACq9 , l o.. A i*x.• 49TH %\ *9 6. DSD SIGNATURE om" .C; •. X. System #1 Approved for bedrooms �f BenjamjrnSchiller • � �F•• CE 12592 System #2 Approved for bedrooms •4i�srF.• . `` ® �' Disapproved �11,0, PROFESSIONA Conditional approval for bedrooms, with the following stipulations: ( Mei/G �NP�LNIPER 5555 PRO RSM `G ��ArCA�T CSO . Original Certificate Date: Z—I Q The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality •of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA b'ue sheet f c If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: Valli Vue Estates #2 Block 1 Lot 71 Parcel ID: 015-123-34 A. WELL DATA Well type A If A. B, or C provide PWSID# 210605 Well Log (Y/N) Date completed Sanitary seal (Y/N) Wires properly protected (Y/N) Total depth ft. Cased to ft. Casing height (above ground) in. FROM WELL LOG AT INSPECTION Date of test Static water level ft. ft. Well production g.p.m. g.p.m. WATER SAMPLE RESULTS: Coliform colonies/100 mL Nitrate mg/L Arsenic ug/L Date of sample: Collected by: B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Date installed 4/18/94 Tank size 1000 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout(Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N Date of pumping 7/27/18 Pumper Isaac's Pumping C. ABSORPTION FIELD DATA Date installed 10/7/75 Soil rating (g.p.d./ft2 or ft2/bdrm) 125 SF/BORN System type Trench Length 42 ft. Width 3.0 ft. Gravel below pipe 4.5 ft. Total depth 11 .5 ft. Eff. absorption area 378 ft2 Monitoring tube Y Depression over field N Date of adequacy test 7/24/18 Results (Pass/Fail) Pass For 3 bedrooms Fluid depth in absorption field before test 8* in. Water added 451 gal. New depth 46 in. Elapsed Time: 1 440 min. Final fluid depth 0 in. Absorption rate >= 450 g p d None Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot >100' On adjacent lots >100' Absorption field on lot >100' On adjacent lots >100' Public sewer main '75' Public sewer manhole/cleanout 100' Sewer/septic service line >25' Holding tank X75' Animal containment areas >50' Manure/animal excrete storage areas 100' SEPTIC/HOLDING TANK ON LOT TO: Building foundation •2 Property line >5 Absorption field >5 Water main Water service line >10' Surface water >100' Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: Property line 10 Building foundation 10 Water main 10 >10' >100' Water Service line Surface water Driveway, parking/vehicle storage >10' Curtain drain None Noted Wells on adjacent lots >100' F. COMMENTS *Trench pre-soaked with 2,203 gallons before testing G. ENGINEER'S CERTIFICATION 41�t\\A of q�glli I certify that I have determined through field inspections and r tp review of Municipal records that the above systems are in ���P• conformance with MOA COSA guidelines in effect on this date. � : •• ` '• *9 Benjamin Schiller, PE Engineer's Printed Name % VP• • • `P'. � Date 7/30/18 Benja chiller•• / 00 e",... • CE10252 •.�44%1 1 (iN'. � I%POFESSO COSA brown sheet 10-10-12.doc / \ 7253 SIT 70 s;, LOT 72 a t90,/ G \F Q6, 56 8 `9V- 0( 1-0107 ,tt� E `Z �` LOT 71 ":; ".';� 1:; .............. MUNIOIP^LITY OF ANCHORAGE ~ ........ . .... :-~,.,~%,;,~: :,,..~., P.O. Box:~196650.~, Anchorage, Alaska 99519-6650 = ~? ~ ~:-.,:~'~.,~ ~?~.~.~.wCER'rlF OATE OF HEALTH AUTHORITY ............... -:: ~ e .::: .+ ::,~ ::-!: ,!~ ~.~:'. APPROVAL FOR A SINGLE FAMILY DWELLING GENE AL INFORMATION Campiete legal d~scnpbon Lo~. 11 r 8ZocE 1,-.~ v~ E~ . ?~_..::;~.~;~:...Unless:othe,n4/!se.requested, HAA ~tll be held fo~, , ............ 2.-- NUMBER OF BEDROOMS: - · :~:f~'L:~'~:.~ 3.~.~PE OF_WATER SUPPLY. ~ .. L.::~.;:~5 .__ .:. ~:_: ..... ' 4~:~.~).:(:..~.) }:~_.~ NOTE:z.: If communi~.'.w~!l/~stem, provide'Wfi~en confi~ation from State.DEC a~est- - ...:-.:¢~ tng to the legah~ and status of system. -. ' - ~,.._ ~ ~PE WASTEWATER DISPOSAL ........ ........ ~ ..... -- -., ..........~ HOld ng tank ...... ~'-.-~ .......... ::' .......... Pubhc sewer ....... :: ..:-.? ~ '-]~ ~*~]~ .:.. NOTE: If communt~ wastewate[ sys~e~, prowd~ wn~en confirmattonfrom State ADEC . STATEMENT OF INSPECTION BY ENGINEER :,~:,.. · As cert,fied ~ ~'.Se~l ~ffixea horo{o and as of tho validation' date sho~ be, low I verify that my inve~ii~ti°n: ~:.{his Heaitfi A~h~rj~PPr~vai:~l~li~i~:Sh~WS ihat'th~n;Site water Supply and/~ Waste~at~¢ diSP°~i Syste~' is Safe;'f~hCli°~a'l ~ha ~deq~t~ f0r the number °f ~edrooms and ~ of stru~iu~e indicated herein. I f~h~r veri~'i~a~'~a~d ~h the inform~ti0n obtained from · the Municipali~ of Anchorage files and from my invest~ation and insp~tion ~he on-site water supply and/or w~tewater d~sposal system ~s m compliance w~t~ all Mummpal and State codes ordinances, an~ regulabons in eff~t on the date of th~s ~ns~ct[om ' Name ~f Firm ~ ~ = =~C:~==~ ~ ' Phone 7' / . Engln~fs signature ~;O ...... ' ~"- " Approved for .~ ' ........ bedrooms. '"' ''*~ · - - .,m,,.~ · · ......... __ : · .......... . .......... ~ ;: ,:., .... .. ~ ~, D sa~Droved. , ,7,. '-". Conditional approval for .... bedrooms,, with' tho following stipulations: By. The Municip~,lity of A~cho?age Department of Health and Human S~;rvic~s (DHHs) issues Health Authority Approval Certificates based only upon the representations given m paragraph 5 above by an indepenOent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct.inspections or. anal~r~e data before a certifiemte is issued. The Mun,ic pa ty of Anchorage is not resPonSible fo~' errors 0~'~m'issions in the professional ~ngineer's w~ik, ~ -"!?.-'."" ;:~l:rl::'. . '~ ~ [ Municipality of Anchorage Department of Health and Human Services HEALTH AUTHORITY APPROVAL CHECKLIST A. Well Data Well type CONi,r.4i~d['/y If (~, B, or C, attach ADEC letter. ADEC water system number Log present (Y/N) AJ//~ /%//~'- Driller Date completed Total depth /~//~ Cased to ~//,~- Casing height ~ Sa~itary seal (Y/N) ~)1/~r- Wires properly protected (Y/N) LOG Date of test Static water level Well flow Pump level1 Absorption field on lot . · Public sewer main Sewer service line SEPARATION DISTANCES FROM WELL TO: Septic/h~d~ng tank on lot ~.,0C~ ' 4- g.p.m. AT INSP/ECTION ; On adjacent lots ~ // ; On adjacent lots ~.,~ Public sewer manhole/cleanout ~ Petroleum tank /?//~ WATER SAMPLE RESULTS: Coliform Date of sample: /~//,/~ Nitrate /~,~ Other bacteria /~,/~ Collected by: ~[//~ B. SEPTIC/~TANK DATA Date installed /'f/[~ Ic) t~ Tank size Cleanouts' ~tN) y~-~ Foundation cleanout (~_/N) High water alarm (Y~ J/~J/~- Alarm tested (Y/~)~ Date of pumping , . ' ,-- ~/'~J/d '7~/b'.JK__ Pumper SEPARATION DISTANCES FROM SEPTIC/H~L-'BING TANK TO: Well(s) on lot . /~J,~- : On adjacent lots Absorption field To property line r~.r3 Surface water/drainage Compartments -~ Depression (Y/I~ ¢00 Foundation Water main/service line 72-026 (3~3)* Front CONTINUED ON BACK PAGE Date installed Size in gallons Vent (Y/N) "Pump on" leve'l'~----_, Manufacturer Manhole/Access (Y/N) ~ .2Pu~vel at High water alarm level Meets MOA electrical codes (Y/N) ~ SEPARAT~~TATION TO: ¢,,~We~t On adjacent lots Date installed Length ~2' Total absorption area _ Date of adequacy test Water level in absorption field before test Peroxide treatment (past 12 months) (Y/¢ D. ABSORPTION FIELD DATA Width Soil rating ((~!~'D/FF) System type -~'~l~fdOl4 ,'~ ~ Gravel thickness ~,~ / Total depth /~L ' Cleanout present (~IN) /VE.~ Depression over field (Y/I~ /L)~ Results (pass/fail) ~,~ for '~ Bedrooms ,~ u After test ~/~ ~//dO~/~ If yes, give date /J//~ SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Well on lot To building foundation On adjacent lots Sudace water Curtain drain On adjacent lots ¢0.o0 '-/- Properly line l 0 '-]- To existing or abandoned system on lot Cutbank /'J//~ Water main/service line t~)O'~ Driveway, parking/vehicle storage area E. ENGINEER'S CERTIFICATION I certify that I have checked, verified, or conformed to ell MOA and HAA guidelines in effect Signature Engineer's Name Date ~" /~' / CE - 8501 HAAFee$ ~Y-~'~ Reoe, t Numar 72-026 (3/93)* Back Waiver Fee $ Date of Payment Receipt Number__ MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4720 Application Date 1. GENERAL INFORMATION (a) Legal Description (include lot, block, subdivision, section, to~vnship, range) Location (address or directions) (b) Applicant Name ~7~-~/ ~ 1~5 Telephone: Home '%~--Z~q-o Business~} Applicant Address ~ ~ ~0~ ~ ~-(~ ~-, - ~O~_14 (c) Applicant is (check one): Lending Institution ~; Owner/builder~; Buyer ~; Other (d) Lending Institution ~ Telephone (e) Real Estate Company and Agent Address Telephone (f) Mei~the HAA to the~olJ, o~..i~o~add[.~ss.: .~.~ TYPE OF RESIDENCE Single-FamilyJ~ Multi-Family [] Number of Bedrooms '~ Other WATER SUPPLY Individual Well [] Community'~ Public~ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Page I of 2 SEWAGE DISPOSAL Onsite ~ Public [] Cor~munity [] Holding Tank [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. ~.~ 72 02fi {11/84) ENGINEERING FIRM PROVIDING INSPECTIONS TESTS, FILE SEARCH DATA AND NFORMAT ON AS certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained 'from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm ,~ ,~ E~' E',']~I~E~I~,w~:-~ Telephone Address ~:., Date / / Approved ~q~_"~,~ bedrooms b Approved ~ Disa;~t ' Terms of Conditional Approval ~ Date ~)Conditional CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 ~, C. ABSORPTION FIELD DATA Soils Rating ia Absorption Strata Type of System Design Date Installed , t L~,-- ~- ~7~' Width of Field ~,~. li Square Feet of Absorption Area Depression over Field (Y/~ Results of Last Adequacy Test Separation Distance from Absorption Field: Length of Field Depth of Field Gravel Bed Thickness ,~"'7 ~45' Standpipes Present ~¢N) Date of Last Adequacy Test To Water-Supply Well To Building Foundation Lot To Water MCtmYService Line To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area To Property Line To Existing or Abandoned System on ; On Adjoining Lots ¢,~rZ.~ ~J,--- To Cutbank (if present) Comments D. LIFT STATION Date Installed Dimensions Size in Gallons "Pump On" Level at ~'3 High Water Alarm Level at Tested for Manhole/Access (Y/N) "Pump Off" Level at Vent (Y/N) Pumping Cycles during Adequacy Test. Meets MOA Electrical Codes (Y/N) Comments ** Check Permitted Bedroom Rating Against HAA Request I certify that I have checked, verifi.ed, or conformed to all MOA and H.,~A guidelines in effect on the date of this inspection. S gned --~'.~ ~ ~,~' !¢.~,l(~!~:~.~t~t,~ Date Receipt No. Date of Payment Amount: $ Page 2 of 2 72-026 (11/84) , D~T. OW ENTV~RONMEN~/~L ~ONS~RV~T]ON ANCHORAGE/WESTERN DISTRICT OFFICE 437 "E" STREET, SUITE 303 ANCHORAGE, ALASKA g9501 BILL SHEFFIELD, Telephone; Address: 274-2533 TO Whom it May Concern: According to records on file in this office the c=~'~~ Water Systemis in Compliance wi th the State Water Regulations DEPT. OF HEALTH & MUNICIPALITY OF ANCHORAGE ENVIRONMENTAL PROTECTION DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION  825 L Street- Anchorage, Alaska 99501 AU B 2 5 1981 ENVIRONMENTAL SANITATION DIVISION Telephone 284.-4720 R E C E 1 V E P REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing, PHONE 1, PROPERTY OWNER PROPERTY RESIDENT J~f different from above) P 2. BUYER MAILING ADDRESS 3. LENDING INSTITUTION 4. RE.ALT/pR/AGENT - ' /~.,.~ ~ '-/_~ /tAILING ADDRESS 5, LEGAL DESCRIPTION STREET LOCATION NUMBER OF BEDROOMS 6. TYPE OF RESIDENCE [] One [] Four ~ SINGLE FAMILY [] Two [] Five [] MULTIPLE FAMILY [~ Three [] Six [] Other 7, WATER SUPPLY [] INDIVIDUAL'~ COMMUNITY [] PUBLIC UTILITY * ATTACH WELL LOG. A well log is required for all wells drilled since June 1975. For wells drilled prior to that date, give well depth (attach Jog if available.) 8. SEWAGE DISPOSAL SYSTEM ~. INDIVIDUAL/ON-SITE** [] PUBLIC UTILITY YEAR ON-SITE SYSTEM WAS INSTALLED. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 6/79) t ~ '~ "' Page 1 of 2 72 026(11184) ALASKA EIUIRORmE RTAL CONTROL SE!RUlCeS, ~nclin¢¢~'imj 8 ~nuironmental $1udics INC. 9/2/81 SEeP 2~ 1981 RECEIVED MARLYS DODD 3800 DET.T~OOD PLACE ANCHORAGE ~ 99504 SRLL~ - RICHARD FIRTH JR. SUBDIVISION-VALLRY VIEW 92 BLOCK-1 LOT-71 ADEQUACY TEST FOR SEWER SYST~4 THE TYPE OF ABSORPTION SYSTEM IS A TRENCH WITH AN AREA OF 378 SQFT. THE SYST~ IS CAPABLE OF ACCEPTING 450 GALLONS OF WA'J.'~t PER DAY. THE SURGE CAPACITY OF THE SYST~4 IS 750 GALLONS. BASED UPON THE TEST DATA THE SYSTEM IS AC~Z~TABLE FOR A 3 BEDROOM HOME. THE SEPTIC TANK WAS PUMPED ON 9/23/80 . SEPTIC TANK ADEQUACY THE EXISTING SEPTIC TANK VOLUME OF 55{IS 3 RRDR00M HOUSE. 1000 IS ADEQUATE FOR 1220 LUest 25th Au~nue · Anchora§e,/~leska 99503 · [907) 276-1361 825 "L" STREET ANCHORAGE, ALASKA 99501 (907) 264-4111 GEORGE M, SULLIVAN, MAYOR August 31, DEPARTMENT OF HEALTH AND ENVIRONMEN]'~I PROTECTION Richard Firth, Jr. % Marlys Dodd 3800 Delwood Place < Anchorage, Alaska 99504 Subject: Lot 71 Block 1 Valli Vue Estates Subdivision Approval for the individual sewer and water facilities cannot be granted until the following items have been completed: #2 (1) ...~,~( 2 ) ~(3) The standpipes to the septic tank and the seepage pit need to be raised above ground level. This will need to be re-inspected when it has been completed. The septic tank pumped with a receipt submitted to this office. An adequacy test needs to be performed on the existing leaching area. This test will determine if the system is adequate according to National Standards. A listing of private firms performing the test is enclosed. This report needs to be submitted to this office for our review. If there are any further questions, please call this at 264-4720. office Sincerely, Robert C. Pratt, R.S. Associate Specialist RCP/ljw cc: First National Bank of Anchorage Post Office Box 720 99510