Loading...
HomeMy WebLinkAboutVALLI VUE ESTATES #2 BLK 1 LT 74Municipality of Anchorage On-Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181225 PID Number: 015-123-37 Dwelling: 0 Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ❑■ Upgrade Name Dan & Julia Suver ABSORPTION FIELD ❑ Deep Trench 0 Wide Trench ❑ Bed ❑ Mound Site Address 6910 Crooked Tree Dr, Anchorage, AK 99507 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 830-2687 4 6.0 GPD/SF 6.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 2.8 Ft. Gravel depth beneath pipe 3.2 Ft. Subdivision Block Lot Valli Vue Estates #2 1 74 Fill added above original grade 0.7 Ft. Gravel length 20 Ft. Township Range Section Gravel width 5.0 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption LiftStation Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 172 Ft2 1 Ft. Well N/A N/A N/A N/A >25 TANK ❑ Septic ❑ S.T.E.P. ❑ Holding X Other Manufacturer Advantex F.A.P. Capacity 1,500 Gal. Surface Water >50' >50' N/A N/A Material Number of compartments Lot Line >5' >10' N/A N/A NA Fiberglass 2 Foundation > 1 0' > 1 0' N/A N/A LIFT STATION Manufacturer Capacity Remarks A 4 bedroom tank was installed instead of a 5 Gal. bedroom tank. See change order on permit. Alarm location Electrical installed by PIPE MATERIAL House to tank D3034 drainfield Tank to D3034 Installer PCN Drainfield D3034 CO/MT D3034 Inspector J. Millette BENCH MARK (Assumed elevation) 100 ft Inspdection 1s` 10/8/19 n 10/9/19 Location and description 2 3" 4,h Threshold of back garage door. ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp F 14 Conditional Approval: Date ............ ®® w 49th e ®'�.....�.�... ... I................................... ® �MICHAEL E. ANDERSON Septic System ldj%�,�1/`P�f/C1{ ® . �p No. CE-4381 _® ,•' Approved Date �D�a ®®�F,p'••.,Fo , 12/4/19 ,.•••''•t���� Note: this approval does not include well permit requirements. ®®f l '°R0F ESS10P � ®m,e®se � ®®®a® kmev UD/UZI 10) VALLI VIDE ESTATES #2, BLOCK 1 LOT 74 wazlivilk EXISTING WATER LINE (ROUTING UNKNOWN) i 2 LOT 73 g FR EW 1500 -GAL ADVANTEX FAP TANK W/AX20 POD FC Hl 2CO H2 col ALTERNATE SITE 2 NEW 204,T 'T Gx5-WIDE Lo IVE DEP -x, ABS"01<PT N TRENCH 32 00, GE PID # 015-123-37 LOT 74 0 40 80 FEET = SLOPES > 25% 1 11=40' MN SLOPES > 46% A B FCO 16.5 51.9 MH1 32.3 48.3 MI -12 40.3 53.0 2CO 44.3 52.8 C01 60.5 68.5 MT 77.7846 CO2 78.7±iH LEGEND CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE RAI I IT1 - • • 91.1 ENGINEERING PID # 015-123-37 94.6 FINISH GRADE OUB 93.9 ORIGINAL GRADE O U Y `DWAINFIELDL?OCIZ 87.9 20 87.9 81.4 NO GROUNDWATER 7/17/19 PROFILE AS -BUILT (NO SCALE) :• 49th . ....•...... �.....:' ........... ... ...'v.—�- ..� i�'a...�...... " MICHAEL E. ANDERSON � �� �, NO. CE -4381 �_� Lot 73 �O �C,,00 N Fx�st/ X21 79 N o"Se / \ Cleano4Tank \ \ Lot 74 Septic Manholes \ 21,501 V, '0 \ Vents �g ° \ \ Septic Lot 71 \ \ r G \S / L \ RP Lot \ / Lot 70 \ /Lot 69\ 321 CA O co Legal Description: Asbuilt Lot 74, Block 1, Valli Vue Estates Unit No. 2 Lot 75 o�� OF Adv°off ?* 9TH enjamin Ho m om 0 el sLS 1 8�a Ofessiono\ oma' Survey Certification: I hereby certify that a Mortgagee's Inspection was performed on the described property. Notes: It is the owner's responsibility to determine the existence of any easements, covenants, or restriction which are not on the recorded subdivision plat. Checked by. CB I Drawn by: AR I Scale 1" = 30' Job 2018-35 Field Book: 142 Plat 72-133 Legend: Rebar O Water Valve 9 Septic QS Pavement Overhang Wood Deck Concrete Fence Grid SW2539 Date: 4/6/2022 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program a; PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP181225 Work Type: Septic Upgrade Tax Code Number: 01512337000 Site Legal Address: VALLI VUE ESTATES #2 BLK 1 LT 74 G:2539 Site Mailing Address: 6910 CROOKED TREE DR, Anchorage Owner: SUVER DANIEL W & JULIA M Design Engineer: FORGE ENGINEERING This permit is for the construction of: Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Effective Date Expiration Date: �o j41R.3vvi' . n Depal-tment 10/18/2018 10/18/2019 Lot Size in Scl Ft: 21501 Total Bedrooms: ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received B� Issued By: 3/Z -71q Ca # I Cbtuv yrst C « to a n J I AXzo pool. y S 1500 9a ad✓a� }c� -I-un is Date: Date: aZlill q 00403 MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On-Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION o t S - !Z3-3J-- Parcel I.D. °58k-5 Property owner(s) Dan & Julia Suver Day phone 830-2687 Mailing address 6910 Crooked Tree Dr, Anchorage, AK 99507 Site address 6910 Crooked Tree Dr Legal description (Sub'd., Block & Lot) Valli Vue Estates #2, Block 1 Lot2 Legal description (Township, Range & Section) Lot Size 21 ,501 Sq. Ft. Number of Bedrooms 5 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: IN all that apply) Absorption Field ❑X Initial Single Family (SF) Septic Tank [ Upgrade [x] (w/wo ADU) Duplex (D) Holding Tank ❑ Renewal ❑ — Multiple Dwellings ❑ Privy n (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. 3 ' (Signature of property owner or authorized agent) Permit/Rush Fees: 450 - Waiver Fees: Date of Payment: -4-/at`CS Date of Payment: Receipt Number: 8-7-5-36 iID Receipt Number: Permit No. Waiver No. Permit App__-:•:L.,c PO BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) July 25, 2018 MOA Development Services Dept- On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Valli Vue Estates #2 Block 1 Lot 24 - Septic system design Dear On-Site Services Engineer: The owner of the above lot would like to upgrade their aging septic system, so we are submitting this permit application for the construction of a new system. The attached site plan identifies the location of the home and existing system, as well as the proposed septic location and alternate site. There are no private wells on the adjacent properties, since the area is served by a public water system. The lot has flat areas in the northeast and southwest portions of the property, but otherwise slopes from the northeast to the southwest at about 10-20%. There are no large slopes, but there are some short portions that slope greater than 25% within 50 feet downslope of either proposed septic site. Fortunately, these are very short slopes and meet the requirements of section 15.65.210.B.1.e. Drainage arrows are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. The soils investigation revealed two different soil layers. The upper layer perked at less than 1 min/in. However, the lower layer perked at an acceptable 3.5 min/in. Therefore, we are not proposing a filter sand layer in the upper section of the trench, as the layer underneath will serve as protection for the aquifer. Please refer to the attached test hole logs, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE 7/25/18 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181225, Deb Wockenfuss, 10/18/18 7 00.0 710.0 710.0 700.015. 8 %17.1% 2 0 . 0% 24 . 6 % 3 1 . 1 %17.8%ALTERNATE SITE MIN 10' SEPARATION FCO 8040 0 FEET 1"=40' 20' LONG x 5' WIDE, 3' EFFECTIVE DEPTH ABSORPTION TRENCH EXISTING WATER LINE (ROUTING UNKNOWN) 2500-GAL ADVANTEX TANK W/ 2 x AX20 PODS MIN 5' FROM DECK SUPPORTS NOTE: NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND CO MT TH#1 CROOKED TREE D R I V E VALLI VUE ESTATES #2, BLOCK 1 LOT 74 Jul 25, 2018 SLOPES > 25% SLOPES > 46% 3-B E D R O O M HO M E 1 0 ' UT I L I TY EASEMENT CO REMOVE EXISTING CRIB REMOVE EXISTING SEPTIC TANK 2CO Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181225, Deb Wockenfuss, 10/18/18 DESIGN FACTORS: SYSTEM REQUIREMENTS: 750 GPD PEAK FLOW PERK RATE: < 5 MIN/IN APPLICATION RATE: 6 GPD/SF 5' WIDE TRENCH SYSTEM 2500-GAL ADVANTEX TANK W/ 2x AX20 PODS TYPICAL TRENCH SECTION (NO SCALE) 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 5' 6" 6" 2'-6" 3' Jul 25, 2018 NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY BOTTOM OF TRENCH: 6' BELOW GRADE FLOW LINE ELEVATION: 3' BELOW GRADE TOP OF TRENCH: 6" ABOVE GRADE 750 GPD / 6 GPD/SF / 5' WIDE * 0.58 REDUCTION = 14.6 LF TRENCH REQUIRED (20 LF SPECIFIED) VALLI VUE ESTATES #2, BLOCK 1 LOT 74 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181225, Deb Wockenfuss, 10/18/18 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TEST HOLE 1 SLOPE SLOPE SITE PLAN See Site Plan DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP TEST HOLE PRESOAKED PRIOR TO TESTING: PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) Valli Vue Estates #2 B1 L74 7/7/18 N. SHAFER Development Services Department 4700 Elmore Road Anchorage, AK 99519-6650 Municipality of Anchorage DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH OF WATER AFTER MONITORING: IF YES @ WHAT DEPTH? NO - None 0.38 6 2.5 3.5 015-123-37 Dan & Julia Suver Professional Engineers Stamp: Jul 25, 2018 17:17 - 17:27 7/7 1 2 3 4 5 6 1:55 4 0 16 - 10 0 16 4 - 1017:30 - 17:32 17:33 - 17:35 17:41 - 17:43 17:44 - 17:46 17:47 - 17:49 1' OB SILTY SANDY GRAVEL (SM) 7/17/18 10 2:01 1:49 2:14 2:16 6 0 16 4 - 10 4 - 10 4 - 10 4 - 10 6 6 66 6 6 SAND W/ GRAVEL (SP) Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181225, Deb Wockenfuss, 10/18/18 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TEST HOLE 1 SLOPE SLOPE SITE PLAN See Site Plan DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP TEST HOLE PRESOAKED PRIOR TO TESTING: PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) Valli Vue Estates #2 B1 L74 7/7/18 N. SHAFER Development Services Department 4700 Elmore Road Anchorage, AK 99519-6650 Municipality of Anchorage DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH OF WATER AFTER MONITORING: IF YES @ WHAT DEPTH? 3.5 6 5 6 015-123-37 Dan & Julia Suver Professional Engineers Stamp: Jul 25, 2018 16:00 - 16:10 7/7 1 2 3 4 5 6 10 4 0 16 - 6 8 16 4 - 6 10 16 4 - 6 11 16 4 - 6 13 16 4 - 6 14 16 4 - 6 14 16 16:11 - 16:21 16:23 - 16:33 16:34 - 16:44 16:56 - 17:06 17:07 - 17:17 10 10 10 10 10 2 8 16 2 10 16 2 11 16 2 13 16 2 14 16 2 14 16 Perk test in TH#1 in deeper soil layer Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181225, Deb Wockenfuss, 10/18/18 MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT,herein the "AGREEMENT" made and entered into as of this 1 Z- Day of of 20 I , by and between Julia SL'/Z 7 ,herein the"OWNER,"and the Municipality of Anchorage, herein the"MUNICIPALITY". in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as Advantex System located at (legal description) Valli Vue Estates #2, Block 1 Lot 74 2. Maintenance,Repairs and Alterations. (Owner is required to read, understand and initial each section) ifr. . Throughout the term of this Agreement. the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall he maintained in a satisfactory' condition capable of performing as designed and producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. It shall be the responsibility of the Owner during the term of this Agreement to pay for all 0)/1/11 repair(s), maintenance,adjustment(s), replacement costs,and inspection costs. This includes an annual maintenance fee(typically $400 to$600). /v` Owner agrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system. )caner acknowledges that regular maintenance of an AWWTS reduces the potential r---4 failure of the system, which could include sewage backup and costly repairs or drainfield replacement. (rev. 05118/2018) Page 1 of 3 Owner acknowledges that the Municipality may request records of maintenance and repairs from the manufacturer's representative or maintenance provider. (7._ Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60.030. Owner agrees to grant the Municipality reasonable access to test and inspect the I .AWWTS. The Municipality will give at least 24-hour notice. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On-Site Systems Approval. Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction, maintenance and repair of the Owner's AWWTS. kA, -- Owner agrees to maintain remote monitoring of the AWWTS as required by the AWWTS approval. 3. Term. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system,or upon transfer of title, and shall continue while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Agreement or any part hereof,or the right of the Municipality thereafter to enforce every provision hereof. 5. Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. Severability. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05/18/2018) Page 2 of 3 OWNER: �l p By: __. (signature) Date: \ItAka IUL J VVQ( (print name) STATE OF ALASKA ) )ss. THIRDJUDICIAL DISTRICT ) The foregoing.instrument was cknowledged before me this lY .,41„f 20 /$ by J i,t.r i /G/ i,1, _ �� t,,.. . pct`• ;NOTARY NOTARY PUBLIC FOR Al4 'K My Commission expires: & 40/0 PUBLIC 2•aa`,.•.F4 MUNICIPAALITY: By: � '" �� (signature) Date: (print name) Title: (rev. 05/18/2018) Page 3 of 3 Legal Description: Plot Plan Lot 74, Block 1, Valli Vue Estates Unit No. 2 Drainage Proposed Finish Grade PFG 100.0' Elevation 100.0' Legend: Survey Certification: I hereby certify that a Mortgagee's Inspection was performed on the described property. Notes: It is the owner's responsibility to determine the existence of any easements, covenants, or restriction which are not on the recorded subdivision plat. It is the contractor's responsibility to check top of foundation grade & building setbacks in relation to property lines and easements Checked by. THD I Drawn by: CB I Scale 1" = 30' Job 2018-35 Field Book: 142 Plat 72-133 Rebar Water Valve Septic QS Pavement Overhang Wood Deck Concrete Fence Grid 2539 Date: 6/7/2018 : GREA ' ANCHORAGE AREA BORC r H ~1~/ Department of Environmental Quality ~ 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME '~'));H';~,l':/-~ /</~i~-V~'/';L'i.O'- 9 MAILING ADDRESS PHONE ~/ 7 '/F)2'2-~ SEPTIC TANK: DISTANCE ~4~ ~ FROM WELL '~¢'d'~'b~I~(- INSIDE LENGTH /¢~/ . , . (%1_ . ~ NUMBER OF MANUFACTURER (_e_.,l& MATERIAL 'J cE_~' .~ COMPARTMENTS I INSIDE WIDTH "'- LIQUID DEPTH -" _LIQUID CAPACITY. /('?~) ~'~ GALLONS. SEEPAGE PIT: NUMBER OF PITS / DIAMETER "--~ OR WIDTH ~D'~',' LENGTH ~'2~'/ DEPTH / ~ / LINING MATERIAL'-)I¥''z ~{i~m CRIB SIZE: DIAMETER''~ DEPTH ~ DISTANCE FROM: · . ~ TOTAL EFFECTIVE BUILDING FOUNDATION,2(/ , NEAREST LOT LINE ,~('? ¢ ~ ABSORPTION AREA (WALL AREA) WELL ~¢~¢ ~ wY%' , SQ. FT. ADDITIONAL ABSORPTION ..... WELL: ' TYPE ~ (~"h/b i'l'( ~( 2~ L ¢,~-j CONSTRUCTION DEPTH DISTANCE FROM: BUILDING NEAREST NEAREST SEPTIC SEEPAGE FOUNDATION __ LOT LINE SEWER LINE TANK SYSTEM CESSPOOL OTHER SOURCES APPROVED DISAPPROVED REMARKS DISTANCES: LOT SLOPE: .. DIAGRAM OF SYSTEM G.A.A.B. Form NO. LQ~031 GREATER ANCHORAGE AREA BorouGH SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT PERMIT NO. INSTALLATION LOCATIOH MAILING ADDRESS PHONE INSTALLATION OF: SEPTIC TANK ~ SEEPAGE PIT / ,~DRAIN FIELD TYPE AND SIZE OF faCiLITY TO BE SERVED >~ 71 ~ / / FINANCED THROUGH TO BE INSTALLED ~Y ., OTHER NOTE= THIS PERMIT IS NOT VALID WITHOUT SOIL TEST COMPLETION DATE ANTICIPATED FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. WELL TO SEPTIC TANK , SEePage Pit DRAIN FIELD CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING gAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE Pit FITTED WITH AIRTight REMOVAI3LE CAps. CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. - / /'.~ 'a'7^.^.~. OR I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 2B-68 AND THAT THE ABOVE GREATER ANCHORAGE AR%A BOROUGH DEPARTMENT OF ENVIRONHENTA~ QUA[.fTY 3330 "C" Street ANCHORAGE, ALASKA 99503 Performed For Legal Description: Lot 7~__Block This Form Reports Soils Log ~<- - Soil Test Must Be Logged To 4' Depth Feet Soil Characteristics -C-~'s-F'-# Dated Performed I~,-~-~N Subdivision]Vjccl~ ~JfJ~ Percolation Test Was Ground Water Encountered? NO If Yes, At What Depth? Below Proposed Seepage System - ill Reading Date Percolation Rate Minute Gross Time Net Time J Depth to H20 Proposed Installation: Seepage Pit Drain Field Depth of Inlet Depth to Bottom of 'Pit or Trench CO~.,~ENT~: _~,~1 ~.~ o~l~, ,~ ,,,~.~ ~/,,,~,'~ Net DroP Test Performed BY Date Certified BY:_ Date: December 23, 1974 GAAB Dept. of Enviornmental Conservation 3330 C Street Anchorage Attn: Rolf Strickland Re: lot74 block i Valli Vue Subde Gentler~n This is a supplemental soils report for the above referenced subdivision lot. A test hole 18 feet in depth was observed on December 7, 1974 and a soils report was filed with your department. Additionally a second observation of the lot was made pursuant to a request by your department. It was observed during this supplemental observation that a large pit had been excavated at the location of the original test holeo In one corner of the pit a smaller excavation to a depth of 24 feet had been made. There wag no water to a depth of 24 feet in this pit. The soil type remained the same from 18 feet to 24 feet. If you have any questions concerning these matters, please contact me. Thank you. Sincerely, Thomas A Sexton 82OO E. 3rd ~nchorsge 99504 INSPECTION APPOINTMENTS TIME TIME TIME DATE DATE DATE INSPECTOR mPEOTDR NSPECTO MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & ) DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECff~ONMENTAL PROTECTION ENVlRONMENTALSANITATION DIVISION JUL 1981 Telephone 264-4720 REOUEST FOR APPROVAL OF INDIVIDUAL WATER AND SE~ ~A~L~T~ DIRECTIONS: Complete al) parts on page 1. Incomplete requests will not b~ proce~ed. Please allow ten (10) days for processing. 1. PROPERTY OWNER PHONE MAILING ADDRESS PROPERTY R~SIDENT (If different from above) ~ PHONE 2. BUYER PHONE MAILING ADDRESS LE~DI~G INST TOTION PHONE MAI LING A. DDRESS MAILING ADDRESS 5. LEGAL DESCRIPTION TREET LOCATION $. TYPE OF RESIDENCE NUMBER OF BEDROOMS [] One [~ Four ~ SINGLE FAMILY [] Two [] Five [] MULTIPLE FAMILY ~ Three [] Six [] Other 7. WATER SUPPLY [] INDIVIDUAL* * ATTACH WELL LOG, A well Icg is required for all wells drilled [~ COMMUNITY since June 1975. For Wells drilled prior to that date, give well [] PUBLIC UTI LITY depth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM ~ INDIVIDUAL/ON-SITE~ YEAR ON-SITE SYSTEM WAS iNSTALLED. [] PUBLIC UTILITY NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS [] SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2, WATER SUPPLY [] INDIVIDUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTI LITY Connection Verified LOG RECEIVED 3, SEWAGE DISPOSAL SYSTEM PERMIT NUMBER [] INDIVIDUAL/ON -SITE DATE ~NSTALLED []PUBLIC UTILITY ~ :2 ~' _.u~ t,f. Connection Verified INSTALLER [_-]Septic Tank or [] Holding Tank Size: .f';~(~)-~-- 0 If Tank is homemade SOILS RATING give dimensions: -~'YPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL (~ ;((~ -4. DISTANCESwELL TO: Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line ~bsorption Area to nearest Lot Line 5, COMMENTS ~PPROVED FOR --~ BEDROOMS [] CONDITIONAL APPRQVAL (letter must accompany certificate) DATE DISAPPROVED BY / ~ ) MUNICIPALITY OF ANCHORAGE [3'~,'...~ .,: ,,!', J. F,.; ~::': I.)~  DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION 825 L Street-Anchorage, Alaska 99501 [ ENVIRONMENTAL ENGINEERING DIVISION ~' ' ' ~: ' ~"'i~'~ Telephone 264-4720 '. REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES Robert Opalinski ~ ..... her ~ork MAILING ADDRESS /~ Star Route A Box 31P 99507 MAI LING A DDR ESS 3', =LENDING INSTITUTION National Bank of Alaska MAI LING ADDR ESS Pouch 7-025 99510 4. REALTOR/AGENT MAILING ADDRESS PHONE % Ruth LA Bar 276-1132/288: IPHONE 5. LEGAL DESCRIPTION Lot 74 Block 1 Valli Vue Estates Subdivision SIREEI LOCATION 6. TYPE OF RESIDENCE NUMBER OF BEDROOMS [] One [] Four ~ SINGLE FAMILY . [] Two [] Five [] MULTIPLE FAMILY OX Three [] Six · [] Other 7. WATER SUPPLY [] I NDIVI DUAL* * ATTACH WELL LOG. A well log is required for all wells drilled ~ COMMUNITY since June 1975. For weJJs drilled prior to that date, give well [] PUBLIC UTI LITY depth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM :~ INDIVIDUAL/ON.SITE** [] PUBLIC UTILITY **If individual/on-site, give installation date Approx. 1.97 5 If system is over two (2) years old an adequacy test is required by this Department. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010(3/78) THIS SIDE FOR OFFICIAL USE ONLY DATE RECEIVED INSPECTION APPOINTMENTS TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR INSPECTOR '~)IR ECTIONS: 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS ~'"~N G L E [] ONE [] THREE [] FIVE [] OTHER FAMILY [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2, WATER SUPPLY coDiViDUA L DEPTH OF WELL MMUNITY DATE DRILLED [] PUBLIC UTILITY Connection Verified LOG RECEIVED GE DISPOSAL SYSTEM PERMIT NUMBER I DUAL/ON -SITE DATE INSTALLED E3PUBLIC UTILITY Connection Verified INSTALLER(~ ~ f~lSeptic Tan~;,gr []Hol(ling Tank Size:__(~ ~ ~)o If Tank is homemade SOILS RATING give dimensions: TYPE O F T~~ M A N U F A C~.~,~,.~ TOTAL ABSORPTION AREA MATERIAL 4. DISTANCES WELL TO: Septic/Ho]ding Tank Absorption Area Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line [] APPROVED FOR BEDROOMS [] CONDI'FIONAL APPROVAL (letter must accompany certificate) [~ DISAPPROVED DATE BY ITitle) LEGAL DESCRIPTION 72-010 (Rev. 3/78) PENINSULA ENGINEERING MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTEI & ENVIRONMENTAl- pF¢OTECTION i 4 ' 981 RECEIVED August 6, 1981 RE: Lot 74 Block 1, Valli Vue #2 Sewage Disposal System Adequacy Test Dear Ms. Gail Opalinski: As per your request we have performed the adequacy test on the sewage disposal system for the home legally descrived above. The test was run in accordance with Municipalit~ of Anchorage recommended test procedures for the 3-bedroom home. In accor- dance with Municipal records the system was installed in 1974 and consists of a 1000 gallon septic tank with 4" ~ standpipe and a 25' x 25' seepage pit with a 4" ~ standpipe. The septic tank was pumped at the beginning of the test (receipt attached) and water was added to the seppage pit @ approximately 10 gallons/minute and the depth in the seepage pit monitor at regular intervals (see attached tabulation). After 500 gallons had been pumping into the seepage pit there was no significant change in Water level so the second daily supply was added directly thereafter. Based on the results of this test we find the seepage pit is functioning adequately. Although the level in the septic tank was not monitor because of accessibility, there was no evidence of any possible backup from the seepage pit into the tank. We therefore conclude that the system appears to be functioning adequately. Sincere ly, Wayne ~nderson 2820 'C' street, Suite #3 * Anchorage, Alaska 99503 * 276-4855 PgNINSULA ENGINgF-.RING ADEQUACY TEST (ii ienE: Gail Opalinski Address: 6910 Crooked Tree Drive [,('g;ll: Lot 74 Block 1' Valli Vue #2 System: Septic Tank with Seepage Pit ] I I)l'11"1'11 I)I,iI'TII ~,qAII.,R AI)I)[,,I) IOIAI, I,~AII'.R /'~'1~' :"' n~ '-; '"' (' ",",~"'< """~A';" I'IT "' F:::) ?..A"' ;!))',) full 51" 10 gpm .0 0 After 5 I0 20 Lest nj i n rain rain 30 35 mi n 40 rain 45 men 50 m i n O 20 m i n 25 mira) 30 min 35 mie AO mn Ln 45 rain 50 mnin unknown unknown unknown unknown unknown unknown unknown unknown unknown unknown unknown unknown 51" 51" 51" 51" 51" 51" 51" 51" 51" 51" 51" 51" 10 gpm 10 gpm 10 gpm 10 gpm 10 gpm 10 gpm lo gpm lo gpm lo gpm 10 gpni io gPm 10 gpm 0 .0 100 200 300 400 500 600 700 800 900 1000 · 2. Property Owner: Mailing Address: ?-~ MUNICIPALITY OF ANCHORAC~ '. Department of Health and Environment~i 825 L Street, Anchorage, Alaska 264-4720 uest for Approval of Individual Sewer and Wate~,F~ac%~$ps ~ /~/~ _._. __ _ __._ i :~,~ ii!,~:~,. Name of Buyer: Mailing Address: Lending Institution: Mailing Address: ~~ Phone: Phone: o Realtor/Agent: Mailing Address: Legal Description: ~// Street Location: / Single Family Residence: Multiple Family Residence: Phone: ( )/ Number of Bedrooms:~ ( ) Number of Bedrooms: Water Supply: *Individual Well (/) Public/Community System ( ) If Individual Well, well depth If Community System, name of system Sewage Disposal System: *~n-site System If On-site System, date of installation: (/) Public System ( ) *NOTE: A well log is required on ALL wells drilled since 6/75. ** If on-site sewer system is over two(2) years old, an adequacy test is required by this department. A fee of $25.00 must accompany each request before processing can be initiated. 3/77 AugUst 9, 197~ Robert Opaltnski Star Ro~t~ A An~horag-e, Alas~.a 99~07 on fha s~wer sy~te~ uneil~ %~e fo!l~fng has been completed. wi~h a (3} ~av~ a pe~cola%ion t~st ~rfor~! for adequacy. Prior to ~ u,~rade a p~i'~ m~t b~ issued by this at ~64-4720. Rebert Co ~ratt~ National Ba~k of Alaska % Ruth La Bar Mortgage Lo~n P~Ich 7-~25 99510