MUNICIPALITY OF ANCHORAGE
POUCH 6-650 ANCHORAGE, ALASKA 99502
Department of Health and
Environmental Protection
3330 C Street
Anchorage, Alaska 99503
274-4561
4.1
December 23, 1975
Hr. Michael Smith
Star Route A Box 35-L
Anchorage, Alaska 99507
Subject: Complaint of sewer system
Dear Mr. Smith:
sizing
The records in this office indicate the sewer system for Lot 52
Block I Vali Vue Subdivision has a tank adequate for a three
bedroom residence and an absorption pit that is suitable for a
Spur bedroom home.
This department issued permits to excavators for the number of
bedrooms requested during the time Lot 52 Block 1 Vali Vue was
under construction. Since that time the State Attorney General's
Office has informed this department that an excavator must construct
sewer systems adequate for the residence including the possibility
of finishing off the basement. If the residence was misrepresented
as to size and sewer system design, you may want to contact
Consumer Protection in Anchorage.
If you have any further questions, do not hesitate to contact this
office at 274-4561, extension 135.
Sincerely,
Les N. Buchholz
Sanitarian
LNB/ljh
Municipality of Anchorage Page
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
PermitNumber: ..~lx./ ~¥011~ PIDNumber: Ol,.,,c1~,.~07
Name: ~ ~ C~¢( E. ~ ~4 Wastewater System: D ~ew. B Upgrade
3 V~'~I IN°'°f~edt°ems: B Deep Trench B Shallow Trench ~Bed BMound ~Other
GPD/Sq, Ft.
Subdivision:.. ~ )epth to pipe bottom from original grade: Gravel depth beneath pipe
Ft. Ft.
Township: I Range: I Section: Fill added above original grade: Gr~vel length:
I
Ft. Ft.
WELL: N, 4, ~ New ~ Upgrade Gravelwidth: Numberotlines: I~ista~cebet*een~ines:
Classification (Private, A.B.C): Total Depth: Cased To: Total absorption area: Pipe material:
Yield: GPM~1 Pump 8et at: Ft. I Casing Height Above Ground:Ft. TANK
SEPARATION DISTANCES ~septic ~ Holding B S.T.E.P.
From T*nk Field S~a=io, Tm~k Se~er Lines ~ C~O¢ ~¢ ~
Number of Compartments:
w~,~, > ~oo, LIFT STATION -
LineL°t ~1 Size in gallons: J Manufacturer:
I
Foundation ~ ~ "Pump on*' level at:* "Pump off" level at: ~ High w~ter alarm at:
Curtain Pump Ma~e & Model ~ Electrical inspections performed by:
: Location and Description:
ENGINEER'S SEAL
Inspections performed by: FI~F~ ~ ~c Dates: 1st ~-/9/9y .~.'~z~
Department of Heal~d~ Hum~rvices approval ~ .,H,o~o~s~
Reviewed and approved ~?~"'t
[ I
LOT 42
, EXISTING
,' SEEPAGE-~ SEPTIC TANK
TEST -
HOLE #1
LOT 41 ,' REPLACEMENT SITE
FOR FUTURE 56' LONG
' TRENCH W 4 5' GRAVEL
,' SWING TIES
"-._.. LOT 51
NEW 1250 GAL.
HOUSE
LOT 52
BLOCK 1
,' FROM: COR."A" COR"B"
TO:
C,O, "C" 18,5' 27'
C.O. "D" 26' 27.5'
PLAN VIEW
SCALE: 1" = 40'
FINAL GROUND SURFACE
3' + OVER TOP OF TANK
1250 GALLON
SEPTIC TANK
INV. 94.04
CROSS SECTION VIEW
NOT TO SCALE
TBM (BOTTOM
OF SIDING)
¢
/
/
/
/
/
LOT 52, BLK. 1, VALLI VUE EST #2
SEPTIC TANK REPLACEMENT
AS-BUILT PLAN AND CROSS-SECTION
FLATTOP TECHNICAL SERVICES
14530 ECHO STREET
ANCHORAGE, AK, 99516
SCALE: AS SHOWN
DRAWN BY: TFM
DATE: JUNE, 1994
//
I I
TEST HOLE
LEGAL DESCRIPTION:
DATE PERFORMED:
PERFORMED FOR:
DEPTH
(feet)
1
FLATTOP TECHNICAL SERVICES
14530 ECHO ST.
ANCHORAGE, ALASKA 99516
SOILS LOG -- PERCOLATION TEST
g0-
Lot 52, Block 1, Valli Vue Estates #2
May 9, 1994
Mike Smith
Pt
SM Reddish sandy loam
SM Tan silty sand
SP Gray gravelly sand
SM Tan silty sand
Damp, some smearing
SP Gray gravelly sand
Sidewalls stable
SLOPE
Depth to Groundwater Date
No ~ronndwater 5fl)/94
SM Tan silty sand
No smearing
Becomes gravelly
and hard digging
near bottom
Clock Net Time Percometer Net Drop
Date Reading Time (minutes) Reading (inches)
5/9 8 gallon presoak 12:35 P.M. <1 0 water all gone
PERCOLATION RATE <<1 (minutes/inch) PERC HOLE DIAMETER 6
TEST RUN BETWEEN 9,0 FT AND 9.5 FT
COMMENTS: Test hole dug to determine suitability of replacement site, if original system were re-rated for 4 bedrooms. The perc test hole accepted
8 gallons of water as fast as it could be poured from the container. A sieve analysis of material from perc test hole showed it to be classified as SP
PERFORMED BY FLATTOP TECHNICAL SERVICES. I~'~ ~ CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WiTH ALL STATE AND MUNICiPALs_., GUIDELINES IN EFFECT ON THiS DATE. DATE; ',,.7't.~'/1 ~. '~.~ /~ ~ ~r
[ I
LABORATORY TEST REPORT
R&M CONSULTANTS, INC. giO1 VANGUARD OR. ANCHORAGE, ALASKA 99507 PH 907-522-1707
CLIENT/PROJECT: Flat-top Tech. Services / Valli Voe Estates
TEST ON: Field sample
SOURCE: Insitu
SAMPLED FROM: Lot 52, Block 1
LOCATION: Test hole #1
SUBMITTED BY: Client
DATE SAMPLED: 5/10/94
DEPTH: 9.5'
R&M PROJECT:'
LAB NO.: 4033
FIELD NO.: 1
DATE REPORTED: 5/12/94
DATE RECEIVED: 5/10/94
GRAIN SIZE DISTRIBUTION CLASSIFICATION COMPACTION
SIEVE5. II % PASS SPEC. UNIFIED AASHO t FAA
~% + 10 OPTIMUM MOISTURE:
4" % + 3 MAX. WET DENSITY:
3" % GRAVEL 41 MAX. DRY DENSITY:
2" % SAND 56 CORR. MAX. DRY DENSITY:
1 1/2" % SILT 3.1 % FRACTURE:
1" 100 % CLAY METHOD:
3/4" 96 FSV NATURAL DENSITY:
1/2" 87 LL NATURAL MOISTURE:
3/8" j 78 J PL WEIGHT LOOSE:
#4 59 PI WEIGHT RODDED:
#8 CLASS SP
#10 42
#16 GRAIN SIZE DISTRIBUTION CHART
#20 27 j .............................. .Y~M~T~ ...... I
#30 1.°0 h-i-i-~ ~- '--~ llll ......
#40 15 ~ *o m,,,, I ,,,,,""Il I ,' ,'
-- 6o ,,,~l I ,,,,, ~ ...... ',Ill I I '"" '
#60 7.2 ~.... · ',lll!l '""j
~o .... I', """ ...... IIIII
#80 ~ 4o111111 ' ""Il '"'i', ,
#100 4.5 ~, ,,,~ll I"lll I Hill
m 2o,,,,J J '"'' JJlll i
#2ool3.1 ,o""J IHt~J= I=I,,i 1~ '""= """" ' J I
........ Jl .... ,,, a--~ I1~',',, ,,,,l :
.02MM o IIIII ' IIII !I'1 .
~oo ~o ~ o.~ o.o~ o.oo~
,005MM
---- GRAIN SIZE (mm)
.002MM
TOTAL WT. TESTED: 1,026 GMS.
COARSE SPEC J FINE ! SPEC
! --
I
I-
ORGANIC CONTENT %:
L.A. ABRASION LOSS:
REMARKS:
DELETERIOUS MAT.
MINUS #200 MESH
SOFT FRAGMENTS
COAT & LIG, OR L.T.WT,pT.
CLAY LUMPS
STICKS & ROOTS
FRIABLE PARTICLES
~l ! J I -I--~'
j
I--I i--'
MOISTURE - PERCENT
Tested By: CLP Checked By:
DKJ
PAGE 1 OF 1
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT
PERMIT NUMBER:SW940116
DESIGN ENGINEER:FLATTOP TECHNICAL SERVICES
OWNER NAME:SMITH MICHAEL C T & LINDA L D
OWNER ADDRESS:6640 ROUND TREE DR
ANCHORAGE, AK 99516
DATE ISSUED: 5/05/94
EXPIRATION DATE: 5/05/95
PARCEL ID:01512307
LEGAL DESCRIPTION: VALLI VUE ESTATES #2 BLK 1 L
T 52
LOT SIZE: 20748 (SQ. FT.)
NUMBER OF BEDROOMS: 3 THIS PERMIT: 3
THIS PERMIT IS FOR THE CONTRUCTION OF:
SEPTIC TANK SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 OR 343-4681 AFTER BUSINESS HOURS
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
I I
LOT 43
tt
LOT 42
LOT 41
' ' ' ' -.. LOT 51
~ EXISTING NEW 1250GAL.
,' SEEPAGI SEPTIC TANK
PIT
EXISTING 1000 GAL.
SEPTIC TANK
(TO BE ABANDONED)
HOUSE
LOT 52
BLOCK 1
LOT 53
NOTE: LOTS IN THIS SUBDIVISION ARE SERVED
BY A COMMUNITY WATER SYSTEM. NO WELLS
ARE WITHIN 200 FEET OF THE SEPTIC SYSTEM
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/ LOT 5
BLK. 6
LOT 52, BLK 1, VALLI VUE EST. #2
SEPTIC TANK REPLACEMENT
SITE PLAN
FLATTOP TECHNICAL SERVICES 1 INCH = 40 FEET
14530 ECHO STREET DRAWN BY TFM
ANCHORAGE, ALASKA 99516 DATE: MAY, 1994
NOTE: THIS IS NOT A SURVEYED PLAT.
ALL LOCATIONS SHOWN ARE APPROXIMATE·
GRE: IER ANCHORAGE AREA BOF UGH
~.'.~.~FJF~ Department of Environmental Quality
' ~--~'- 3330 C Street
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
NAME ~-Z;~//~ /~/-/'~C~/~/~'~,/ MAILING ADDRESS ~,~/, ,~dy /f"-~'7 PHONE'~//~Z-//[~"Y/'~'~
LOCATION .//'~/~//t,'~ ~'., /~/2~'~/zJg/ LEGAL DESCR,PTION ,"~//
SEPTIC TANK:
DISTANCE ~ NUMBER OF
FROM WELL/~/~2/~ MANUFACTURER ~'~'~ ~'l-~g,~- MATERIAL -('/'~'~'~ COMPARTMENTS ~
INSIDE LENGTH --' INSIDE WIDTH --' LIQUID DEPTH --' .LIQUID CAPACITY /~ GALLONS.
SEEPAGE PIT:
NUMBER OF PITS / DIAMETER -- OR WIDTH /~/'~:. LENGTH /'~%/ DEPTH
LINING MATERIAL,~/'~[~,['~4~///~CRIB SIZE: DIAMETER Y/DEPTH ~ / DISTANCE FROM: WELL ~~.
BUILDING FOUNDATION~ 1~ NEAREST LOT LINE ~/~ TOTAL EFFECTIVE
ABSORPTION AREA (WALL AREA) ~/~//~/~SQ. FT.
ADDITIONAL ABSORPTION
WELL:
TYPE ,/~/2Z//Z/~/~ CONSTRUCTION, DEPTH DISTANCE FROM:
BUILDING NEAREST NEAREST SEPTIC SEEPAGE
FOUNDATION_ LOT LINE SEWER LINE TANK SYSTEM
CESSPOOL OTHER SOURCES
APPROVED __ DISAPPROVED REMARKS
DISTANCES: , C'/~//~/b
INSTALLED BY:
PIPE MATE RIAL: ~-'~/[/~2~
LOT SLOPE: ~-~/
REMARKS: ~'/~'~/Z2,~//'~
Form NO. EQ-031
DIAGRAM OF SYSTEM
DATE /'~/~/~'/:~/ APPROVED ~ ~Z~
G.A.A.B.
· ' GP' )'ER ANCHORAGE AREA BOROUGH "~
Deparanent of Environmental Quality
- = 333" "~" "' - -
u ~ ~'creer
Ancho'r~ge~ Alaska 99503
PerF°rm~' ~
tn]~ form repolts: So~ls log / , PercolatJon test
Depth
Feet
T -
Was ground water encountered?
If yes, at what depth? '
"Reading
Date
Gross Time
Net Time
Depth to H2O
Percolal;ion rA~e --minute~ .....
Prouosed i ~s~,llat~on Seepage Pit .....
Net Drop
Drain Field '
O.p~.n of Inlef
.. ~ . Depth ~o bottoln of pit or trench ,
Flattop Technical Serv~es
14530 Echo Street, Anchorage, AK99516
Phone (907) 345-1355
Lot 52, Block 1, Valli Vue Estates
6640 Round Tree Drive
Septic Tank Replacement
Specifications
1.0 General:
1.1 The scope of the project consists of abandoning an existing 1000 gallon septic tank and installing
a new 1250 gallon septic tank.
1.2 Construction shall be as depicted on the approved site plan and design drawings. Minor
deviations from these drawings may be allowed or required by the engineer conducting the inspections.
Al/construction procedures and material specifications shall conform with Municipal and State
requirements. All separation distances shall be in confmxnance with Municipal requirements, unless
specifically waived.
1.3 The contractor shall be responsible to obtain any necessary utility locates, and to work around any
buffed utilities.
1.4 The contractor shall provide adequate cover material and rough grading over al/system
components to ensure that proper ch'ainage is achieved after settlement and that there are no residual
depressions. Insofar as possible the contractor shall minimize damage to trees and existing lawn areas.
1.5 Unless specifically agn'eed otherwise, the homeowner shall be responsible for finish grading after
the soil is compacted, as well as placement of topsoil and reseeding all areas disturbed by the construction.
2.0 Septic Tank:
2.1 The existing 1000 septic tank must be properly abandoned by thoroughly pumping, removing the
top and backfilling with soil, or disposal at the Municipal landfill.
2.2 The new 1250 gallon, 2 compartment septic tank shall be Municipally approved and shall be set
level on undisturbed soil. Each compartment shall be equipped with a watertight manhole cover and a 4"
cleanout. If the tank is buried less than 4 feet, it shall be insulated with 2 inches of approved burial type,
rigid insulation. ~
2.3 All pipe connections to the tank shall be equipped with waterproof mechanical couplings. The
waste line fi'om the residence to the septic tank shall have a minimum slope of 1/4'" per foot, and the waste
line between the tank and the soil absorption system shall have a minimum slope of 1/8" per foot. A
cleanout shall be installed within 5 feet of the building foundation, and a double cleanout shall be installed
within 5 feet downstream of the septic tank.
3.0 Inspection:
3.1 One engineering inspection will be required after the new tank has been set level and the piping
connected, but prior to backfill. The installer shall coordinate the timing of the inspection with the
engineer sufficiently far in advance to ensure the availability of the engineer.
I I
m ;>
0 1~ 1
~ o
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On-Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
Parcel I.D.#
GENERAL INFORMATION
Complete legal description
Lot 52; Block I; Val~ vUe EstateS #2
Location (site address or directions)
Property owner
Mailing address
Mike Smith
6640 Round Tree Drive
A~¢ho~age~ AK
Lending agency
6640 Round Tree Drive Anchorage,
Day phone 346-2551
AK 99516
Day phone
Mailing address
Agent
Address
Day phone
Unless otherwise requested, HAA will be held for pickup.
NUMBER OF BEDROOMS: $ ~
TYPE OF WATER SUPPLY:
Individual well
Community well XXX
Public water
NOTE:
If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system.
TYPE OF WASTEWATER DISPOSAL:
Individual on-site
Holding tank
Community on-site
Public sewer
NOTE:
XXX
If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72-025 (Rev, 1/91) Front MOA #21
STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage files and from my inves!i_gation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection.
$ & $ ENGINEERING ~ Phone _~'c/~'. ~-~,
Name of Firm .
17034 Eagle River~p~d No. 2~
Engineer's signature Date
DHHS SIGNATURE
X Approved for ~ bedrooms.
Disapproved.
Conditional approval for
bedrooms, with the following stipulations:
Additional Comments
Date /2_ - ,/~T _,.C,.y
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineer's work.
I I
Municipality of Anchorage
Department of Health and Human Services
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: /~-5~,0-//7-~-/~ I/ ~.~_L~.7_- ~/c~ ,~-57 Parcel I.D.
A. Well Data
Well type ~IA/~/VI'~,/ .If A, B, or C, attach ADEC letter. ADEC water system number
Log present (Y/N) d//'~ Date completed ~ Driller ,,'~/'//~
Total depth ~/~ Cased to ~./~ Casing height/t///~
Sanitary seal (Y/N) ~'~/~ Wires properly protected (Y/N)
FROM WELL LOG AT INSPECTION
Date of test
Static water level
Pump level1
SEPARATION DISTANCES FROM WELL TO:
Septic/holding tank on lot
Absorption field on lot ~00 '~ ; On adjacent lots ,f~'/,,/}
Public sewer main /~/,~ Public sewer manhole/cleanout
Sewer service line ~'/y~tr- Petroleum tank ~CYU?~ /~zV0~J
WATER SAMPLE RESULTS:
Coliform
Date of sample:
Nitrate
/~.//~ Ot~e//~acte ria /~]"
Collected by:
B. SEPTIC~I~TANK DATA
Date'installed 5/ab / ~ ~ Tank size /~ ~-,,~-'~-- Compartments
Cleanouts{~N) 0/~ F'-_ /Y~',~- Foundation cleanout (~N) /~/'C, Z, Depression (Y/N)
High water alarm (Y/N) ~J//~ Alarm tested (Y/N)
Date of pumping /0 -/~ - ? ~ Pumper ~t~/~C~
SEPARATION DISTANCES FROM SEPTIC/t!I~ TANK TO:
Well(s) on lot /LJ/~ On adjacent lots ~ ~ '~ Foundation
To property line O~~ ~4 Absorption field ] ~ ' Water main/service line
Surface water/drainage I O0 /-
72-026 (3/93)* Front CONTINUED ON BACK PAGE
~-~.C.~LI~FT_ _"-~STATION //~
Date inst"~la [ed~. Manufacturer
Size in gallons ~ Manhole/Access (
Vent (Y/N)__ __ ~M~ ~ ....-.-"'""~" P u mp off" Level at
High water alarm level _ ~ Cycles tested ~
Meets MOA electrical cedes (Y/N) ~ ~
SEPARAT~~ STATION TO: ~
On adjacent lots
Wet Sudace water
D. ABSORPTION FIELD DATA
Date installed
Length I ~ '
Total absorption area
Date of adequacy test
Width
Soil rating (GPD/Ft2)
~ ~ Gravel thickness
Cleanout present ~)
Results (pass/fail)
Water level in absorption field before test
Peroxide treatment (past 12 m~nths) (Y/~
ABSORPTION FIELD TO:
On adjacent lots
SEPARATION DISTANCE~'ROM
Well on lot
To building foundation
On adjacent lots
Systemtype ~'El~(n~'- '/~/7
Total depth /
Depression over field (Y/~) /'~Jo
for ~' Bedrooms
If yes, give date
c~ Ofj ~F- Property line
To existing or abandoned system on lot
/v,//) Water main/service line
Surface water
Curtain drain
Driveway, parking/vehicle storage area
E. ENGINEER'S CERTIFICATION
HAA Fee $
Date of Payment
Receipt Number
I certify that I have checked, veri' , or conformed to all MOA and HAA guidelines in effect on the da~e"o~ this inspection.
Engineer's Name~..-.e.~NG!N~.ERIN.O ........ ,::''
Waiver Fee $.
Date of Payment
Receipt Number.
72-026 (3/93)* Back