On -Site Wastewater Disposal System Permit
Permit Number: OSP231315
Work Type: Septic Upgrade
Tax Code Number: 01532253000
Site Legal Address: VALLI VUE ESTATES #2 BLK 2 LT 5 G:2538
Site Mailing Address: 10630 LONE TREE DR, Anchorage
Owner: BOLDING ROBERT L & TRACY L
Design Engineer: FORGE ENGINEERING
This permit is for the construction of:
Effective Date
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms:
o`Zcnr�.S.
Department
9/22/2023
9/21/2024
27376
Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received By:
Issued By:
S �r�
G s
Date:
Date:
ZL� Zo Z 3
1----
0
Community Development Department _ Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 015-322-53
Property owner(s) Bob Bolding
Mailing address 10630 Lone Tree Drive, Anchorage AK 99507
Site address 10630 Lone Tree Drive, Anchorage AK 99507
Day phone (907) 230-0700
Legal description (Sub'd., Block & Lot) Valli Vue Estates #2, Block 2 Lot 5
Legal description (Township, Range & Section)
Lot Size 27,376 Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(N all that apply)
Absorption Field
®
Initial ❑
Single Family (SF) ❑X
(w/wo ADU)
Septic Tank
❑X
Upgrade FX]Duplex
(D) El
Tank
❑
Renewal ❑
Multiple Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: u7_rjR� Waiver Fees:
Date of Payment: ���F/ Zo Z3 Date of Payment:
Receipt Number: 7 Receipt Number:
Permit No. 0E, p%-2, ) 3 IS Waiver No.
Permit App_::- : :'-.,:c
September 13, 2023
MOA Development Services, On-Site Water & Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: Valli Vue Est #2 B2 L5- Lone Tree Drive
Septic system design
Dear On-Site Services Engineer:
The owner of the above lot would like to upgrade the septic system on his lot to accommodate
four bedrooms, so we are submitting this permit application for installation of a new tank and
septic field. The attached site plan identifies the location of the home as well as the existing
septic tank and field.
The ground surface on the lot fairly uniformly to the northwest at about a 10-15% slope. There
are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site.
Contours are shown on the site plan showing the grade and direction of flow. Stormwater
drainage will not impact this septic system. The new trench will be constructed parallel to the
slope as much as possible.
The existing trench was constructed across the lot line, and will be abandoned. The new trench
will maintain a 14’ separation from the existing trench. There are no wells on this or adjacent
lots, as all are fed from a community water system in the main ROW. The new tank and trench
will be 10’ away from the building foundation and lot line. Either a foundation cleanout or a
double cleanout will be installed upstream of the new tank.
Please refer to the attached test hole log, plan and profile pages for the septic design. If this
design is followed, there will be no adverse impacts to adjacent properties.
Sincerely,
Benjamin Schiller, PE
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP231315, Curtis Townsend, 09/22/23
//
//
//
//
//
//
//
//
//
//
//
//
//
//
//
//
//
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
1"=50'
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
2CO
TH1
VALLI VUE ESTATES #2, BLOCK 2 LOT 5
FEET
0 50 100
≥14'
FCO
NOTE:
THIS LOT AND SURROUNDING LOTS IN THE VALLI VUE #2
SUBDIVISION ARE ON A COMMUNITY WATER SYSTEM.
LON
E
T
R
E
E
D
R
I
V
E
3-BDRM HOME
650
SEPTIC PLAN
9/13/23
O'MALLEY ROAD
PAVED RETAINING
WALL
DECOMMISSION EXISTING 1,000
GAL STEEL TANK PER UPC
NEW 1,250 GAL
SEPTIC TANK
PROVIDE FCO OR
2CO BEFORE TANK
ABANDON EXISTING
TRENCH ENCROACHING
ON NEIGHBORING LOT
640630
620
610
CO
CO
75' LONG x 5' WIDE, 4' EFFECTIVE
DEPTH ABSORPTION TRENCH
MAINTAIN 10' SEPARATION FROM
PROPERTY LINE AND 14' FROM
EXISTING TRENCH
MT
MT ALTERNATE SITE:
CAT III ADVANCED TREATMENT
20' LONG x 5' WIDE x 4' EFFECTIVE
TRENCH
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP231315, Curtis Townsend, 09/22/23
VALLI VUE ESTATES #2, BLOCK 2 LOT 5
TYPICAL TRENCH SECTION
(NO SCALE)
NOTES:
1. GRADE AREA OVER TRENCH TO DRAIN AWAY
2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
4" PERFORATED PVC
(HOLES DOWN)
DRAINFIELD ROCK
4'
DESIGN FACTORS:SYSTEM REQUIREMENTS:
600 GPD PEAK FLOW
PERK RATE: 3.14 MIN/IN
APPLICATION RATE: 0.8 GPD/SF (CONSERVATIVE)
5-WIDE TRENCH SYSTEM
1250-GAL SEPTIC TANK
BOTTOM OF TRENCH: 7' BELOW GRADE
FLOW LINE ELEVATION: 3' BELOW GRADE
GEOTEXTILE FABRIC
9/13/23
PROVIDE ADDITIONAL MIN 6" FILL
TO ACCOUNT FOR SETTLEMENT
5'
600 GPD / 0.8 GPD/SF / 5' WIDE * 0.5 RED FACTOR [4' DEEP] = 75 LF TRENCH REQUIRED (75 LF SPECIFIED)
6"
2'-6"
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP231315, Curtis Townsend, 09/22/23
LEGAL DESCRIPTION:
PERFORMED FOR:
DATE: PARCEL ID#:
SOILS LOG AND PERCOLATION TEST
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
DEPTH
(feet)
TEST HOLE 1
DATE READING START TIME NET TIME
(minutes)
DEPTH to
WATER NET DROP
PERCOLATION RATE: (MIN/INCH)
(inches)(inches)
DATE OF MONITORING
WAS WATER ENCOUNTERED?
DEPTH TO WATER AFTER MONITORING
IF YES @ WHAT DEPTH?
3.14
8/23 1
2
3
4
5
6GM (SILTY SANDY GRAVEL)
Professional Engineers Stamp:
NO
VALLI VUE ESTATES #2, BLOCK 2 LOT 5
8/23/23 015-322-53
BOB BOLDING
10:33 1
OB
30
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
PERC TEST LOCATION
TECHNICIAN: M. Jakubisin
7
-
DRY
8/31/23
COMMENTS:
SITE PLAN
>6 0 16
USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED
9/13/23
BOH
7
10:50 1 10 6 11
16 5 1116
110 4 15
16 3 15 16
110 4 12
16 4 12 16
110 4 6
16 3 6 16
110 4 4
16 3 416
110 4 3
16 3 3 16
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP231315, Curtis Townsend, 09/22/23
Lot 5, Block 2
Valli Vue Unit No. 2
27,376 Sq. Ft. +/-
10630 Lone Tree Drive
2 Story Wood Frame House
With Attached 2 Car Garage
PA
V
E
D
D
R
I
V
E
W
A
Y
SH
E
D
16
.
2
N89° 59' 45"W 166.66'
N34
°
2
3
'
4
3
"
E
2
9
7
.
1
4
'
N1
5
°
0
0
'
0
0
"
E
2
2
6
.
5
1
'
26
.
3
24
.
2
50.
1
22.
1
12
.
2
PAVED RET.
WALL
MB
3.0
10.2
26
.
9
81
.
6
PAVED RET. WALL
9.8
S
LOT 6
LOT 4
L=63.51
R
=187.62 EDGE OF PAVEMENT
℄LO
N
E
T
R
E
E
D
R
I
V
E
CULVERT
G
E
75
.
0
30
'
R
.
O
.
W
.
34.
0
10
.
1
6.1
S
S
℄ O'MALLEY ROAD
PROFESSIONAL SEAL
Date:Frontier Surveys, LLC Project No:
650 W. 58th Ave. Suite E Anchorage, Alaska 99518
As-Built Survey of:
www.frontiersurveys.com
Frontier Surveys, LLC
I, Pierre Stragier, hereby certify that this Mortgage Inspection Survey was performed by me, or
under my direct supervision on
Plat:Grid:Ordered By:
907.460.1686 - info@frontiersurveys.com
This survey complies with the ASPLS Mortgage Location Standards. The survey represents visible improvements and
conditions at the time of the survey. This document does not constitute a boundary survey and is subject to any
inaccuracies that a subsequent boundary survey may reveal. It is the responsibility of the Owner to determine the
existence of any easements, covenants, or restriction which do no appear on the record plat. Under no circumstances
should this document be used for construction or for establishing a boundary or fence line.
August 6th, 2021.
Legend:
Scale 1" = 40'
Gas Meter
Electric Meter
Deck
Septic Fence MailboxS
G
E
Lot 5, Block 2 Valli Vue Estates No. 2
General Notes:
1. This document is created for the purpose of a single property transaction and is subject to Federal Copyright Laws.
2. Excepting for gross negligence, the liability for this survey shall not exceed the cost of preparing this survey.
3. All measurements/setbacks are to the visual/apparent building footprint.
4. All dimensions to property lines are plus/minus 0.1ft.
Nora Delolli
21-467 07/23/2021
77-296 2538-39
x
S T A T E O F ALA
S
K
A
49 TH
ROYEVRUSDNALLANOISSEFORP
DER
E
T
S
I
G
E
R Pierre M. Stragier
NO. LS-9812
08/06/2021
MB
Light Pole
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street - Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
NAME
/
PHONE ~r~EW
NO. OFBEDROOM~.~
Dwelling
Materia~)
Width
IF HOMEMADE: Inside lengtb..~.~ Liquid depth__
Well Dwelling PERMIT NO.
DISTANCE TO: W~'F./t'~K -
NO. of li~s~_~ Length of each ne
Top of tile to finish grade
Width
~ / ,~1 Nearest lot line
Total length of lines Trench
Material beneath tile
PERMIT NO,
Total effective al
Depth
PERMIT NO,
Crib diameter Crib depth Total effective absorption area
Well *; Suilding foundation ' SepticNeareSttankl°t line
Depth Driller Distance to lot line PERMIT NO,
DISTANCE TO: foundation Sewer line Absorption area(s)
OTHER
PIPE MATERIALS
SOIL TEST RATING !
INSTALLER
REMARKS
APPROVED
72-013 (l~v. 3/78)
PERMIT N0.
( 80055~ )
8PPLICBNT JRK CONST.
LOCRTION V8LLI VLIE
! C ! P--r.;IL :[ -r'~? OP- t-]NCH;~'RFi,SE
DEPBRTMENT 0, HEBLTH BND ENVIRONMENTBL ~ .OTECTION
82:5 "'L" STREET., RNCHORFIGE., RF'.". 9950:L
264-4?20
25±t CHILKFtT CT. i~)Ni~,~ .
694 _.i_ i
LEGFIL LOT ~., BLK 2 YFILLI vUE: EST. LOT _,I,.E 2?000 _,t~UFIRE FEET
TYPE OF :,OIL BB_,ORPTIuN ~_,TEM IS: TREN_.H j;j bl-(~/], ~,~
MFt:qlMUM NI_IMBER GF BEDROOMS = ~ SOIL RBTING <SQ FT/BR)= 250 ~L
THE RE..-.' IRED -~I~E OF 'THE _,OIL FtB'~ARPTION SYSTEM I_,.
[:,EPI-H: 11 L E P-.I ~_3 T H'-- e-:5 GRt-]~'EL C.,EPTH: ?
THE LENGTH DIMENSION IS THE LENGTH (IN FEET) GF THE TRENCH OR DRRINFIELD.
THE [EFTH OF R TKENL. H OR PIT I=~, THE DISTRNCE BETWEEN THE SURFRCE OF' THE
GROUND RND THE BOTTOM OF THE EXCRVRTION (IN FEET..
THERE IS NO SET WIDTH FOR TRENCHES.
THE * '- ,'
=~HkEL DEPTH IS THE MINIMUM DEPTH OF G~RVEL .ECETN~E[;~ THE ,OUTFRLL RIPE
BND THE BOTTOM OF THE EXC8VRTION (IN FEET) ....
,=- .
~]LLO~_
RE&qLi I REE:, -_.EFT I C: T~-~( :. I ~E--
F'ERMIT BF'PLIC:BNT HRS THE RE_,FON_,IE, ILIT~ TO INFORM THIS DEPFtRTMENT [:,URING THE
INSTBLLFtTION IN._~FECTION_-, OF FtNY WELLz, 8DJFtCENT TO THIS PROPEF.~TY BN[." THE
NUMBER OF RESIDENCES THBT THE WELL NILL SERVE.
T [,],3 ('. 2. .':, I t'-.l-=. P E~ F:_.T' I O I'-.I S R F..: E R E ~-7! IJ I F:ED
E, HL. KFILLING uF RNY SYSTEM WITHOLIT FINRL IN=,FEL. TIuN RND RPPROV8L 8Y THIS
DEPFIRTMENT WILL BE _,UE, JEL. T TO'PROSECUTION.
MINIMUM DISTRNCE BETWEEN R WELL RND RNY ON-SITE SENRGE DISPOSRL SYSTEM IS
t00 FEET FOR R PRIVRTE WELL OR ±50 TO 200 FEET FROM R PUBLIC WELL DEPENDING
UPON THE TYPE OF PUBLIC WELL
MINIMUM DISTRNCE FROM 8 PRIVBTE NELL TO 8 PRIVBTE SEWER LINE IS 25 FEET 8ND
TO R COMMUNITY SEWER LINE IS 75 FEET.
OTHER REQUIREMENTS MBY 8PPLY. SPECIFICRTIONS BND CONSTRUCTION DI8GRBMS 8RE
8V8ILBOLE TO INSURE PROPER INSTBLLBTION.
F'EF.'I',I ~ T E::<P I RE'---] [:.EL-:EI--18ER --.~:t~
I CERTIFY THRT
1: I BM FBMILIRR WITH THE REQUIREMENTS FOR ON-SITE SEWERS 8ND WELLS RS SET
FORTH BY THE MUNICIPALITY OF 8NCHORBGE.
2: I WILL INSTBLL THE SYSTEM IN BCCORDRNCE WITH THE CODES.
3: I UNDERST8ND THBT THE ON-SITE SEWER SYSTEM MRY REQUIRE ENLBRGEMENT IF THE
RESIDENCE IS REMODELED TO INCLUDE 'MORE TH8N 3 BEDROOMS.
Y4. 0
PERFORMED FOR:
LEGAL DESCRIPTION:
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
SOILS LOG - PERCOLATION TEST
[] SOILS LOG
PERCOLATION
TEST
DATE PERFORMED:
1
2
3-
4-
5-
6-
7-
8-
9-
10-
11
13-
14-
15-
16-
17
18
19
2O
WASGROUNDWATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
o
E
E
NO. 1
June ~2, .19,~8.
Gross Net Depth to Net
Reading Date Time Time Water Drop
c%/~ - -- 5~" '~
TEST RUN BETWEEN
COMMENTS
PERCOLATION RATE -~ ~ (minutes/inch)
/'~' , ET AND I/<-~ FT
CERT,E,ED"Y: fiJ 7t 7- DATE:
72-008 (6/79)
-~'- LJ~ I I I I I I
MUNICIPALITY OF ANCHORAGE.._
iENT OF HEALTH AN? ENVIRONMEN'rA iOTECTION TEST '
Pouch GGhS, Andmrcgo, Ala~a 9S502 276 2221
SOILS LOG - PERCOLATIO~J TEST
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WRAT
DEPTH?
Reading Date
PERCOLATION RATE
1~LC~
_$
4:tZ
Drop
~,07
J
72 008
I~,il..iN[CIPALFFY OF A?JCI-!OR$1
DEPAP<F,%~ENT OF HEALTH A,"~p ENVHqONMENTb
SOILS LOG -- PERCOLATION TES'£
13-
14-
!5
16
17
19
2O
WAS GROUND WATER
ENCOtJNTER£D?
IF YES, AT WRAT
DEPTH?
Reading DaTe
PERCOLATION RATE
DATE RECEIVED
INSPECTION APPOINTMENTS
TIME TIME TIME
DATE DATE DATE
INSPECTOR INSPECTOR INSPECTE~L_~
MUNICIPALITY OF ANCHORAGE DEPT. OF HTAU[;I &
,!AN 2 6 198i
ENVI RONMENTAL SANITATION
DIVISION
Te, epho.e 264-4720 RECEIVED
REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES
LEGAL DESCRIPTION
STREET ~.ODATI Ol'q
6. TYPE OF RESIDENCE NUMBER OF~BEDROOMS ~
[] One [] Four [] Other__
~ SINGLE FAMILY [] Two [] Five
[] MULTIPLE FAMILY J;~ Three [] Six
7. WATER SUPPLY
[] INDIVIDUAL' * ATTACH WELL LOG. A well log is required for all wells drilled
[~ COMMUNITY since June 1975. For wells drilled prior to that date, give well
[] PUBLIC UTI LITY depth (attach log if available.)
8. SEWAGE DISPOSAL SYSTEM
~ INDIVIDUAL/ON-SITE** /? ~'~' YEAR ON-SITE SYSTEM WAS INSTALLED.
[] PUBLIC UTI LITY
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
72-010 (Rev. 6/79)
THIS SIDE FOR OFFICIAL USE ONLY
1. TYPE OF RESIDENCE NUMBER OF BEDROOMS
[] SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER
[] MULTIPLE FAMILY [] TWO [] FOUR [] SIX
PERMIT NUMBER
2. WATER SUPPLY
[] INDIVIDUAL DEPTH OF WELL
[] COMMUNITY
DATE DRILLED
[] PUBLIC UTI LITY
Connection Verified LOG RECEIVED
3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER
[] INDIVIDUAL/ON -SITE DATE iNSTALLED
[]PUBLIC UTILITY
Connection Verified INSTALLER
L~Septic Tank or []Holding Tank
Size: If Tank is homemade SOILS RATING
(Jive dimensions:
--TYPE OF TANK MANUFACTURER
TOTAL ABSORPTION AREA MATERIAL
'~, DISTANCES Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line
WELL TO:
Absorption Area to nearest Lot Line
5, COMMENTS
[~_~PPROV ED FOR _-~ BEDROOMS
[] CONDITIONAL APPROVAL (letter must accompany certificate)
[] DISAPPROVED
--DATE By )~
72-010 ( Rev. 6/79)