ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP231094 PID Number: 015-322-43
Dwelling: ® Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ® Upgrade
Name
JEREMIAH & ANDREA MOSS
ABSORPTION FIELD - EXISTING
❑ Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound
Site Address
6201 CORNER TREE DRIVE, ANCHORAGE
❑ Other
Phone
Phone 7��
f Bedrooms
Soil Rating
depth from original grade
4
GPD/SF
JTotal
Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
Ft.
Gravel depth beneath pipe
Ft.
Subdivision Block Lot
VALLI VUE ESTATES #2 2 15
Fill added above original grade
Ft.
Gravel length
Ft.
Township Range Section
Gravel width
Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
Ft2
Ft.
Well
2001+
--
25'+
TANK ® Septic M S.T.E.P. ❑ Holding ❑ Other
Manufacturer
GREER
Capacity
1500 Gal.
Surface Water
100'+
--
Material
HDPE
Number of compartments
2
Lot Line
5'+
__
NA
Foundation
10'+
__
LIFT STATION
Manufacturer
GREER / ORENCO
Capacity
1500 Gal.
Remarks
Alarm location
BACK WEST WALL
Electrical installed by
DRS
Installer JRS
to
PIPE MATERIAL House to tank 3034 Tank to 3034
rainfield
Drainfield CO/MT
Inspector FWC
BENCH MARK (Assumed elevation) 100 ft
Inspection 1" 5/19/2023 2nd 5/19/23
Location and description
3rd 4"'
TOP OF MANHOLE / 6' RISER
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
•''•.� ��
Conditional Approval: Date
Q1`.'•
lowTH
.. - ....�... r�
�r Curtis Huffman
�•, CE 128991
(P�F • . 5/23/23 . • s
Septic System
Approved -'%
Date
• �C�
l�;F� ...AW
pROFESSIO�
Note: this approval does not include well permit requirements.
.N
�iwv vvivu 10)
PID:015-322-43 PERMIT:OSP231094
FIRST WATER CONSULTING
VALLI VUE ESTATES
BLOCK 2, LOT 15
VALLI VUE ESTATES BLOCK 2, LOT 15
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP231094
Work Type: SepticTank Upgrade
Tax Code Number: 01532243000
Site Legal Address: VALLI VUE ESTATES #2 BLK 2 LT 15 G:2538
Site Mailing Address: 6201 CORNER TREE DR, Anchorage
Owner: MOSS JEREMIAH J & ANDREA F
Design Engineer: FIRST WATER CONSULTING
This permit is for the construction of:
Effective Date
Expiration Date:
Sir.
J
De pai'tnlent
Lot Size in Sq Ft:
Total Bedrooms:
5/12/2023
5/11/2024
21351
❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received By: 1 5.S14� 0 'To r lj C_ Date:
Issued By: i� Date: S / 7 bo 7- 3
4
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 015-322-43
Property owner(s) JEREMIAH & ANDREA MOSS Day phone
Mailing address 6201 CORNER TREE DRIVE, ANCHORAGE, AK 99507
Site address 6201 CORNER TREE DRIVE, ANCHORAGE, AK 99507
Legal description (Sub'd., Block & Lot) VALLI VILI E ESTATES #2 132, L15
Legal description (Township, Range & Section)
Lot Size 21,351 Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(Z all that apply)
Absorption Field
E]
Initial ❑
Single Family (SF) El
Septic Tank
El
Upgrade I -XI
(w/wo ADU)
Holding Tank
El
Renewal ❑
Duplex (D) ❑
Privy
❑
Multiple Dwellings ❑
(SF and/or D)
Private Well
El
Water Storage
1-1
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: �Z �
Date of Payment: S I-ot 3
Receipt Number: 0
Permit No. 3 L)
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
GAIDevelopment Services\Building Safety\On Site Water and WastewaterTorms\Client FormsTermit Application.doc
13030 Sues Way, Anchorage, AK 99516
907-350-9566 / firstwaterAK@gmail.com
!
!!
May 8, 2023
Municipalities of Anchorage
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
RE: STEP SEPTIC TANK UPGRADE PERMIT
LEGAL: VALLI VUE ESTATES #2 BLOCK 2, LOT 15
We have been requested to obtain a septic permit to upgrade the existing aged steel STEP septic
tank on the above referenced lot. We propose to install a 1500-gallon HDPE tank per the
attached design to serve the existing 4-bedroom residence. No groundwater was noted in the
subject and adjacent MOA on-site files, but if groundwater is encountered during installation an
epoxy coated steel septic tank may be required. The lot and area are served by public water. The
design will not impact any of the neighboring properties. Please contact us if you have any
questions.
Sincerely,
Curtis Huffman, P.E.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP231094, Curtis Townsend, 05/12/23
FIRST WATER CONSULTING
DESIGN DETAILS:
VALLI VUE ESTATES BLOCK 2, LOT 15
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP231094, Curtis Townsend, 05/12/23
Municipality of Anchorage
On-Site Water and Wastewater Program • (907) 343-7904 Page 1 of 2
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: 015-322-43 PID Number: SW970361
Dwelling: ❑■ Single Family(SF) E Duplex(D) ❑ Multiple(SF and/or D) Project: ❑ New D Upgrade
Name:
ROBERT HOWARD ABSORPTION FIELD
Address
❑ Deep Trench ❑ Shallow Trench El Bed ❑ Mound
❑ Other
Phone Number of Bedrooms Soil Rating Total depth from original grade
4 362 GPD/SF 7.5 Ft.
LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe
Subdivision Block Lot 3.5 Ft.4.0 Ft.
VALLI VUE EST#2, BLK 2, LOT 15 Fill added above original grade Gravel length
Township Range Section 0 Ft. 4X45 =181 Ft.
Gravel width Beds:Number of Lines Distance between lines
SEPARATION DISTANCES 2.0 Ft. Ft.
To Septic AbsorptionHolding Sewer Total absorption area Number of trenches Dist.between trenches
From
Tank Field Lift Station Tank Line 1448 Ft2 Ft.
Well NA NA NA 50'+ TANK ❑l Septic ❑S.T.E.P. 0 Holding ❑Other
Manufacturer Capacity
Surface Water 100'+ 100'+ 100'+ ANCH TANK 1500 Gal.
Material Number of compartments
Lot Line 10'+ 10' 10'+ STEEL 2
NA -
Foundation 10'+ 10'+ 10'+ LIFT STATION
Manufacturer Capacity
Curtain Drain UN UN ANCH 1500 Gal.
Remarks
COMM. WATER WELL > 200' Pump on level at Pump off level at High water alarm at
_UNDOCUMENTED SYSTEM, DESIGNED 36 in. 28 in. 40 in.
AND INSTALLED BY UNKNOWN Pump make and model Electrical Inspections performed by
STANDARD UNKNOWN
PIPE MATERIAL House to tank 3034 Tank to 3034
Installer _ drainfield
UNKNOWN Drainfield 3034 Co/MT3034
Inspector UNKNOWN BENCH MARK (Assumed elevation)96.7 ft
Inspectio: 1si 10-18-97 2nd 10/24/97 Location and description
3rd 4th BACK DOOR CONCRETE PAD
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Ennggjne. ,'s,Slamp
Conditional Approval: Date �`��•• %%Pi_1d
ry
14.49Tf �`y •••.. 'S
eij I
r•••
/ •
• / . MICHAEL N. ANDERSON ;
MSC �. P
6.,-;:-' ••• C - 469 :.'-c ••
fl
Approved c.,--__I — Date 5'`�l 1 g f li? of• ••••• ., .. ,
Inspection Report_9-1-12.doc
Permit No. SW970361 Page 2 of 2
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 Anchorage, Alaska 99519-6650 Telephone: 343-4744
On—Site Wastewater Disposal System and/or Well Inspection Report
Legal Description: VALLEY VUE ESTATES #2 BLK 2, LOT 15 PID No.: 015-322-43
MARK A B
C01 25 60
TC01 20 65
TCO2 30 72
CO2 90 97 __
CO3 132 125 N.
C04 125 115 / \
C05 84 85 / TH#•
C06 75 77 /
C07 122 108 I CO4
CO8 118 103 1 CO3 11 1107 Cern
——
co9 75 65 n
MT1 128 122 ` I 1TT2�IT3 �M14
MT2 119 115MT3 115 \ SII II yyJJ
MT4 115 955 /T�—I•I—��ii\
I/ II ITH41 �1., 00011.11..--
\
'" SPILTTERS, NO ACCESS
1:02 : eb6 • ,
DRIVEMY I —
_ /�? \\ TEST HOLE BY OTHERS, SEE MOA FILE
i \
-fi..- fi/; 1
/
/I I I \ • MO 1
I 1Iti 2 \ I ----BENCH ELEV. 96.7'
\\ ITCO `��, �1
1 T.,
C01
•
1500 STEP TANK
11/41
I
ASBUILT
SCALE: 1"=30'
[co. TCO, .�.....• 1I
CO25.5.1. Cp,,}.<,9
611-4
�i'��N N . :��P�• ••. .�
\-57
J '-- '-'-'----9-1.67
ri1L,[R FABRIC 81NSIM,I09 49TH i\ '`.�•:
•
•
92 5 / 1.500 CALLON \ sna.wc \` • •
STEEL STP 10.9 �yys 9}@ •
N
10
996 / 9ss_/ �0 l'..MICHAEL N. ANDERSON'Li,
°B'� wax •G • No. E 94 9 '��/
S• 4'�O%••.,,, •
SEPTIC SECTION
N.T.S. 444▪ i▪ . .'�4••
jerT varness
From: Daniel Kranich <daniel@nusalaska.com>
Sent: Wednesday, June 23, 2021=- Pl
To: David Garness
Cc: David Kranich; Jeff Garness
Subject: Re: 6161 O'Malley Road *Anchorage, AK - O'Malley Fire Station; Lot 2
Attachments: qgis-bin_2021-06-23_15-44-07.png
Hello David,
I have located the water service line for the O'Malley fire station and painted marks on the ground. I have also used that
information to update our map and have attached that map to this email.
I also could not get any signal going to 6161 O'Malley, so I don't believe that property has a water service.
AC
VP
asfmN twdp
ftP
F
Vi
too, 1!
.. . 0.r►�
t
Rick M?strom,
Mayor
Municipality of Anchorage
Department of Health and Human Services
825 "L" Street
P.O. Box 196650 Anchorage, Alaska 99519-6650
http://www.ci.anchorage.ak.us
343-4744
October 16, 1998
Mary E Howard
6201 Corner Tree Drive
Anchroage, Alaska 99516 6716
Subject: Lot 15 Block 2 Valli Vue Estates Subdivision #2
Permit #SW970361, PID #015-322-43
The subject permit, issued October 9, 1997 by this office for a
single family well and/or on-site wastewater system, has
expired as of October 9, 1998.
A new permit must be obtained from this office for a well
and/or on-site wastewater system NOT installed by the
expiration date.
If you have drilled the well, a well log must be sent to
this office for documentation of the installation and to
close the permit.
If a licensed Professional Engineer has inspected the
installation of the on-site wastewater system, the original
as-built inspection report must be sent to this office for
review, approval and documentation. Ail inspection reports
must be submitted within 30 days of construction completion.
When applying for a new permit, the fees are: $320.00 for an
on-site wastewater permit; $120.00 for a well permit and
$440.00 for a combined on-site wastewater and well permit.
If you have any questions, please call this office at 343-4744.
jSa~es~ESi ely, ~]
P~ogram Manager
On-site Services
enc: Copy of Permit
cc: Theta Enviromental Engineering
PAGE 1 OF
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650~ 825 "L" STREET, ROOM 502
ANCHORAGE~ ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT
PERMIT NUMBER:SW970361
DESIGN ENGINEER:THETA ENVIRONMENTAL ENGINEERING
OWNER NAME:HOWARD MARY E
OWNER ADDRESS:6201 CORNER TREE DR
DATE ISSUED:10/09/97
EXPIRATION DATE:10/09/98
PARCEL ID:01532243
LEGAL DESCRIPTION:
VALLI VUE ESTATES #2 BLK
2 LT 15
LOT SIZE: 21351 (SQ. FT.)
NUMBER OF BEDROOMS: 4 THIS PERMIT: 4
THIS PERMIT IS FOR THE CONSTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18RAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3, THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AMD CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
THETA ENVIRONMENTAL ENGINEERING
eE2, 905 Jayme Court
Anchorage, Alaska 99518-2444
(907) 344-1928
Fax: (907) 349-2363
SHEET NO.
DATE. ~'/~/~"/
DATE
THETA ENVIRONMENTAL ENGINEERING
eE2 905 Jayme Court
., Anchorage, Alaska 99518-2444
(907) 344-1928
Fax: (907) 349-2363
2
SHEETNO OF.
CHECKED BY.
/4
18
:>-e /
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L' Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
PERFORMED FOR: BOB HOWARD
LEGAL DESCRIPTION: L15, B2 Valli Vue II
DATE PERF(
Township, Range, Section:
1
2
3
4
5
6
7
8
9
104
11
12-
13-
14
15
16
17
18
19
2O
Organics
ML, Silt, Orange
,ML, Silt, Tan
very consistant
GM, Silty Gravel
Few Cobbles
ML, Silt, Dense
BOH
SLOPE
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH? N/A
Oegm to Water Attor hate:9 / 1 9 / 9 7
Monitoring? .~.T 0 ~.TE
SITE PLAN
Gross Net Depth to [ Net
Reading Date Time Time Water Drop
1 9/11/9' 0 0 0.500 0
10 10 ;500/0. 500 0
20 ,[0 .500/0. 500 0
30 10 .500/0. 500 0
40 10 )/500/0. 500 0
50 10 )f500/0. ~00 0
60 10 .500/0. ~00 0
PERCOLATION RATE 0 (minutes/inch) PERC HOLE DIAMETER 6"
TEST RUN BETWEEN ~J. 5 FTAND 5.0 FT
soils absorption field
PERFORMED BY: t~on Godden ~ ~ CERTIFYTHATTHISTESTWASPERFORMEDIN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: q./? 1 ./q 1
72-008 (Rev 4/85)
PID:015-322-43 PERMIT:OSP231094
FIRST WATER CONSULTING
VALLI VUE ESTATES
BLOCK 2, LOT 15
VALLI VUE ESTATES BLOCK 2, LOT 15
PERFORMED FOR:
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
Bob Howard
TH~3 .
LEGAL DESCRIPTION: L15B2 Valll Vue IIT
--OL, Organics
SM, SiltyTSand, Tan
'Orange
ML, Silt, Tan
Few Cobbles
GM,
Tan
1
2
3
4
5
6
7
8
9-
10-
11
12
13
14
15
16-
17-
18-
19-
20-
Township, Range, Section:
SLOPE
DATE PERFO ~ ,2~.~_.~
SITE PLAN
WAS GROUND WATER
ENCOUNTERED? NO
Silty Gravel
IF YES, AT WHAT
DEPTH? N / A
Depth to Water After
y GravelM0nimrin9? AT9~ Dale:9/!9/97
Dense
I
Gross Net Depth to J
Net
Reading Date Time Time WaterI Drop
1 9/11/9. 0 0 0.60 0
2 10 il0 0.60/0.~ 0.02
3 20 10 0.60/0.5 0.02
4 30 10 0.60/0.51 0.02
5 40 10 0.60/0.5 0.02
6 50 10 0.60/0.5 0.02
7 60 10 0.60/0.5 0.02
PERCOLATION RATE 4 2 [minutes/inch) PERC HOLE DIAMETER ~"
TEST RUN BETWEEN 4 . ~ FT AND ~ . (] FT
COMMENTS Perc Hole Presoaked
PERFORMED BY: ]~. ~c~c] c] p~q I ~) ~F~r~ ~ ~ CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: (3,/1_ ! ,/9 ?
72-008 (Rev. 4/85)
Municipality o! Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage. Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
PERFORMED FOR: Bob Howard
TH~4
LEGALDESCRiPTiON~15,B2, Valli VueII
1
2
3
4
5
6
7
8
9-
10
11
12
13
14
15-
16-
17-
18-
19
20
Townshi
0L, Organics
SM, Silty Sand, Orange
ML, Silt, Tan
few cobbles
DATE PERF(
Range, Section:
;LOPE
WAS GROUND WATER
GM, Silty Gravel ENCOUNTERED?
with cobbles, tan
Dense IF YES, AT WHAT
DEPTH?
BOH
SITE PLAN
NO
Oel)lh Io Water Aitor
Monitoring7 l'~3~q ~ Dale:
Gross Net De~th to Net
Reading Date Time Time Water Drop
1 9/20/9 0 O 0.55
2 10 10 ).55/0.4~ 0.06
3 20 10 ~.55/0.4~ 0.06
4 30 10 ).55/0.4~ 0.06
~ 40 10 .55/0.4~ 0.06
6 50 10 .55/0.4~ 0.06
7 60 10 (.55/0.4~ 0.06
PERCOLATION RATE ] '~ . 0 (minutes/tach) PERC HOLE DIAMETER
TEST RUN BETWEEN z~, 0 FT AND z~, .~ FT
PERFORMED BY: ~- ~odd~t~ I ~, ~c~c~c]¢,~ CERTiFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THiS DATE. DATE: Q,/') (3,/Q"7
72-008 (Rev. 4/85)
Municipality ol Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
PERFORMED FOR: Bob Howard
TH~5
LEGAL DESCRIPTION.~_,I5 · ~--2, V=-!!i
EPTH
V,!e I I
SLOPE SITE PLAN
t
2
3
4-
5-
7
8
9
10
11
12
13
1fi-
18
20
OL, Organics
SM, Silty Sand, Orange
ML, Silt, Tan
GM,
Sand, Clean
Silty Sand, Tan
GP, Sandy Gravel,
WAS GROUND WATER
ENCOUNTERED?
GM, Silty Gravel IFYES, ATWHAT
DEPTH?
Cobbles, Tan
Depth tn Waler After
Monitoring? ~nn~
BOH
I
I
N
,ri, / I
Nn
$
L
.o
E
Da~e: q/gR/q7
9/20/97 0 0 0.55 0
10 10 .55/0.5~ 0.02
20 10 /55/0.52 0.02
30 10 .55/0.5~ 0.02
40 10 .55/0.5~ 0.02
50 10 .55/0.5~ 0.02
60 10 .55/0.52 0.02
PERCOLATION RATE 42 tm,nutes/LnCh) PERC HOLE DIAMETER ~"
TEST RUN BETWEEN 4·0 FTAND 4·,~ FT
PERFORMED BY: m. Godden ~ R. Godden __
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE.
72-008 (Rev 4~85)
CERTIFY THAT THIS TEST WAS PERFORMED IN
DATE: 9/2 0 / 9 7
Depa~tmer1'~ o~ ~4.~ .?~ and"" ca ,-'~*s-
825 '? Sb'eet
P.O. Box ~9a550 Ancno~age. AJasXa995~9-6650
343-4744
August 22, 1997
Mary E Howard
5020 Fairbanks Street
Anchorage, Alaska 99503 7442
Subject: Lot 15 Block 2 Valli Vue Estates Subdivision #2
Permit #SW960259, PID #015-322-43
The subject permit, issued August 21, 1996 by this office for a
single family well and/or on-site wastewater system, has
expired as of August 21, 1997.
A new permit must be obtained from this office for a well
and/or on-site wastewater system NOT installed by the
expiration date.
If you have drilled the well, a well log must be sent to
this office for documentation of the installation and to
close the permit.
If a licensed Professional Engineer has inspected the
installation of the on-site wastewater system, the original
as-built inspection report must be sent to this office for
review, approval and documentation. Ail inspection reports
must be submitted within 30 days of construction completion.
When applying for a new permit, the fees are: $320.00 for an
on-site wastewater permit; $120.00 for a well permit and
$440.00 for a combined on-site wastewater and well permit.
If you~ave any questions, please call this office at 343-4744.
Since?l,y,~ ~
Program Manager
On-site Services
enc: Copy of Permit
cc: Steven R. Pannone, P.E.
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AI~D HUbLAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
PAGE
ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE)
PERMIT KIUMBER:SW960259
DESIGN ENGINEER:STEVEN R. PANNONE
OWNER NAME:HOWARD MARY E
OWNER ADDRESS:6201 CORNER TREE DR
ANCHORAGE, AK. 99516
PERMIT
DATE ISSUED: 8/21/96
EXPIRATION DATE:
PARCEL ID:01532243
LEGAL DESCRIPTION:
VALLI VUE ESTATES #2 BLK
2 LT 15
LOT SIZE: 21351 (SQ. FT.)
IqUMBER OF BEDROOMS: 4 THIS PERMIT: 4
5~IS PERMIT IS FOR THE CONSTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80) o
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
1 OF
8/21/97
SPECIAL PROVISIONS:
EXCAVATE AN ADDITIONAL TESTHOLE NEAR THE EXISTING
TRENCH AND INSTALL A GROUNDWATER MONITOR TUBE AND LEAVE
THIS MONITOR TUBE IN PLACE UNTIL FINAL APPROVAL IS
GRANTED FROM THIS DEPARTMENT. (ENGINEER MUST CERTIFY A
4 FT. VERTICAL SEPARATION EXISTS BETWEEN THE BOTTOM OF
THE EXISTING TRENCH AND GROUNDWATER, OR THE EXISTING
TRENCH MUST BE PERMANENTLY ABANDONED.
RECEIVED BY~ --
Steven R. Pannone, P.E.
Consulting Engineer
(907) 272-8218
P.O. Box 142025
Amchorago, Alaska, 99514
(907)272-8218 Fax
August 14, 1996
Municipality of Anchorage
Dept. of Health & Human Services
On-Site Services Section
P. O. Box 196650
Anchorage, Alaska 99519
Subject:
Lot 15, Block 2 Valli Vue Subdivision, 6201 Comer Tree
Upgrade Permit
Gentlemen:
My firm was contacted to investigate the possibility of installing of a replacement system at the above
referenced property. The existing trench type system has failed. The owners report slow draining of the
lower fixtures and minor backing-up of the drains. The system was installed in 1975. I was requested to
investigate the possibility of installing a new system adjacent to the existing system. A single test holes was
excavated on July 15, 1996 The soil report and percolation test results are attached. Additional soils will be
verified at the time of installation. No ground water was encountered during the seven day monitoring period,
but was measured to be 14 feet below ground level by MOA DHHS personnel on August 12, 1996.
The tot is approximately 1.25 acres in size and is served by a community water system, h slopes to the
southeast at a rate of approximately one to two percent. The proposed installation will be located greater
than 100 feet away from any well and 25 feet from the water service lines. The surrounding systems are
located greater than 100 feet from the proposed installation. The existing septic tank wilt be inspected and if
found competent, reused. A new tank will be installed if the existing tank is not found competent. The
existing soil absorption field will be reused. A diverter valve will be installed between the septic tank and the
two drain fields. The new drain field will be selected for use.
Please contact me at 272-8218 if you have any questions about the proposed installation.
Sincerely,
-3~ven R. Pannone, P.E-~.
Attachments:
C:\WORK~ 15-~VVUE.001
DESIGN
WASTEWATER ABSF1RPTIDN SYSTEM
Lots 15 BLOCK 8 V=[U Vue Estates No.2
Approximately
45 Feet to
property lime,
Soils to be verified
during construction,
Approximately
145 Feet to
ne[bors system,
-SX
Approximately
80 Feet to
property line,
Approximately
115 Feet to
melbors system,
20 Feet to
property
Zabe[ Z2000-~
Ftow
Existing 1850 Q
septic tank, to be
verified during
construction,
NDTE~
1) Lot Is served by ~
community water system,
2) There are No septic
systems within 100 Feet oF
the proposed location,
C~\Work\15-SVVUE.DWG
=roposed Trenchs
Z~be[ Z2OOS~Ir
Flow Divider
ExtstlnD
house
])rlveway
C.L. Corner Tree Circle
PREPARED FDR~
Robert Howard
6201 Corner Tree
Anchorage, AK 99516
(907) 563-4743
l-2z
PANNDNE ENG. SVC
P. D, BOX 148085
ANCHORAGE, ALASKA 99514
274-0308, 878-8818 Fax
OATD 7-84-96 I DESIGN
$~ALE, I'=30'
Soil R~clnQ = 250 sF/br
4 Bedroom House
lOOO sP Rqd
])eslgn~ 5' EFFective
10 To~l ])ep~h
2' Wide, 100' Long
To~c~l absorp~clon = 1000
I)EglGN DETATLS
~/AgTE~/AT£R A])gBRPTInN gYSTEN
Lots 15 ])LOCK 2 valU Vue Estotes No,8
Z
d
PREPARED FOR~
Robert Howard
6201 Corner Tree
Anchorage, AK 99516
(907) 563-4743
PANNDNE ENG, SVC,
P, O, BDX 142025
ANCHDRAGE, ALASKA 99514
274-0308, 278-8218 FAX
DATE, 7-24-9G
~DT TD gCALE DESIGN
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
PERFORMED FOR:
DATE PERFOI
LEGAL DESCRIPTION: /..E,-I' l,~..,'-J~ ~_ ~tA~CPVO~
3-
4-
5-
6
7
8
9-
10-
11
13-
14-
15-
16-
17-
18-
19-
20-
Township, Range, Section:
SLOPE
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
Depth to Water A~ter
M0nit0rinD7 '~'"c'
SITE PLAN
Gross Net Depth -t~ ~F~ Net
Reading Date Time Time Water Drop
PERCOLATION RATE /~ (minutes/inch) PERG HOLE DIAMETER
TEST RUN BETWEEN ~ FT AND "~ FT
PERFORMED BY: ~ '~'~3AJ~ L ~ ~
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE.
72-008 (Rev. 4/85)
CERTIFY THAT THIS TEST WAS PERFORMED IN
DATE: '~ ~'-~-- <~ ~
Zabel Z200 F10w Divider° Zabel Z200,D F10w Director
BRAND NEW FOR 94- The Zabel Flow Divider replaces old fashioned d str bution boxes ,md p pe manifold~
and The Zabel Flow Director replaces expens ye, old ~ashioned Y-valves. They are also more e ~'ec tire and easier
to install. All Zabel products are manufactured fi'om high quality injection no ded PVC nd cam' Zabel'~
Lifetime Warranty if parts fail due to manufacturer s defect in material or worknmnship. The warranty does not
include replacement parts not sold by Zabel and does not include labor for removal or remstallatio~.
The Flow Divide distributes effluent leaving the
septic tank by means ot'a patented central weir
design that insures the flow ~s evenly divided even
if the Flow Divider is not peffecrl¢ level.
The inlet ptpe of the Flow Divider ~s constructed
so fha t eft[uent will flow from it and down into the
effluent into two equal portions.
Distributes flow better than D-boxes and mani-
folds that are subject to (mst heave or ground
settling.
Testing shows that even with a level discrepancy
of i/8" or more between the nght and left port, the
division of the flow was almost 50/50. A standard
D-box or manifold distorts the flow under these
same
conditions.
5-9 ~ 5
Manufactured from injection molded PVC.
Always insures an even flow. -/
Doest~'t create solids bu'ld up ~/
Will not clog.
Lifetime Warranty.
Laboratory Test Results using
1000 mi samples @ 3 gpm
Average
Level Distribution
Right Port 50.03'
Left Port 49 97
1/16" Tilt
Right Port
Left Port 49,5%
1/8" Tilt
Right Port 51.3%
Lett Port 48.7%
The Flow Director is a Flow D~vider wxth a pat-
ented sleeve valve instal[ed to &stribute the effiu-
ent flow to a pnmary field ,~r your choice and
allows the secondan! field to rest until needed.
The Flow Divider automatically back flows t}om
the primar,/to the secondary field and does
depend on the homeowner ro change the sleeve
valve in the Flow Director. A :tandard Y-valve is
dependent on the homeowner :o change the flow
direction at the proper time. Unfortunately, thts
usually does not happen and a problem develops
such as an effluent break out resulting in ground
water contamination.
3. At the time the septic tank t, normally sen'iced,
the septic tank sen'ice company can redirect the
flow allowing the primary field the opportunity to
rest.
Questions concernm= ~2cc Flow Divider · Zabel Z2OO-D Flow Director please call
i -800-221-5742 or Fax (502) 267-8801 for further information.
R
,t ANCHORAGE AREA BOF-}GH
Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
NAME ~
LOCATION
MAILING ADDRESS
SEPTIC TANK:
INSIDE LENGTH /d"/ INSIDE WIDTH LIQUID DEPTH
NUMBER OF
COMPARTMENTS
LIQUID CAPACITY//~ ~¢~GALLONS.
TILE DRAIN FIELD:
DISTANCE FROM WELL (-'~/~¢ ~FOUNDATION 2~ ~-~
! TOTAL LENGTH
NEAREST LOT LINE ~ OF LINES
TRENCH WIDTH ~ /
IN. TOTAL EFFECTIVE
Sq. FT. LENGTH OF EACH LINE
! DEPTH OF FILTER
MATERIAL BENEATH TILE . VE TILE ~' IN.
NUMBER OF LINES
DISTANCE BETWEEN LINES
ABSORPTION AREA
DEPTH: TOP OF TILE TO FINISH GRADE
WELL:
TYPE__ ~¢~'/~'2' /~2~']CONSTRUCTION
BUILDING
FOUNDATION
CESSPOOL
APPROVED __
NEAREST
LOT LINE __
OTHER SOURCES
DISAPPROVED
NEAREST SEPTIC
SEWER LINE TANK
REMARKS
DEPTH
SEEPAGE
SYSTEM
DISTANCE FROM:
DISTANCES:
INSTALLED BY: ~7~, -
SEWER LINE DEPTH:
PiPE MATERIAL'
LOT SLOPE:
REMARKS:
Form LQ-032
Gte,/ 'ER ANCHORAGE AREA BOf dg~--~.jJ
SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT
INSTALLATION LOCATION
INSTALLATION OF: SEPTIC TANK
TYPE AND SIZE OF FACILITY TO BE SERVED
SOIL TEST RESULTS ~¢'~ / / % --/~ / NOTE: THIS P=RMIT IS NOT VALID WITHOUT
COMPLET,ON DATE ANTI CIPATED ~ /¢ 7X
BOIL TEBT
FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION.
TYPE d SIZE
CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING gAP OF
FOUNDATION TO SEEPAGE~-~ , DRAIN FIELD
~o ~ !
SEPTIC TANK TO SEEPAGE'~T~ WALL
5-/ E~~----~¢ 7
SEPTIC TANK SEEPAG , DRAIN FIELD
I CERTIFY THAT I Aid FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE
DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. I also certify that this home will contain a maximum of 4
~'"~-) bedrooms be added
bedrooms. I understand an upgrade wou.l,d--be n~ece. Ssary s~hp.u-ld-'n)ore ·
GREATER ANCtlORAGE AREA I~OROUb,,
Oepartment of Environmental Quality
3330 'C" Street
Anchorage, Alaska 99503
SOILS I,OG ' PEROt,ATION TI~ST
Performed for__ J~_,~.~____~/_~_~_.~__.,
Legal Descripti~i~' -z.~
This form reports: Soils
Percolation test
Depth
Feet
1
2-
3-
4-
5-
8-
9-
10-
11 -
12---
13-
~>-,d /.,z~ >' 6 ,~ Z U ~: L. -- ..? Pv -~ ~ IA/
Was ~ encountered?
If yes, at whaL depth?
Reading
Date Gross Time Net Time epth to
Percolation rate minute.
-Proposed installa~-~? Seepa-ge Pit Drain Field
Depth of Inlet '. Depth t6~-l~6¥tYm-0:F-i)it or trench .................
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval
Parcel I.D. 015-322-43 Expiration Date: G
Legal description VALLI VUE ESTATES #2 BLK 2 LT 15
Site address 6201 CORNER TREE DR Anchorage AK 99507
Current property owner(s) JEREMIAH & ANDREA MOSS
X The On-site system(s) is/are approved for 4 bedrooms
Conditional approval for bedrooms, with the following stipulations:
Comments or advisories:
M
Original Certificate Date: 6/9/2023
This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
system(s) is/are in substantial compliance with municipal code. The Municipality of
Anchorage, Development Services Department (DSD) issues COSAs based upon
representations provided by an independent professional engineer. The Municipality of
Anchorage is not responsible for errors or omissions in the professional engineer's work.
ATTACHMENTS:
COSA Checklist X Well Flow Advisory
Absorption Field Advisory Nitrate Advisory
Tank Age Advisory Arsenic Advisory
Other
COSA Approval_June 2022
MUNICIPALITY OF ANCHORAGE
Development Services Department p p � @ Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval Application
1. GENERAL INFORMATION
Parcel I.D. 015-322-43
Complete legal description VALLI VUE ESTATES #2 BLOCK 2, LOT 15
Location (site address) 6201 CORNER TREE DRIVE, ANCHORAGE, AK 99507
Current property owner(s) JEREMIAH & ANDREA MOSS Day phone
2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS
3. TYPE OF WATER SUPPLY: ❑ Private Well ❑ Private Well serving 2 dwelling units
❑ Private Well serving 3+ dwelling units ® Community Well or Public
❑ Water Storage
4. TYPE OF WASTEWATER DISPOSAL: ® Private Septic ❑ Private Septic serving 2 dwelling units
❑ Holding Tank ❑ Community Septic or Public Sewer
5. SEPTIC TANK: ❑ Steel DQ Plastic ❑ Concrete ❑ Fiberglass
Age /1f fir- See advisory if steel older than 20 years — .1500 STEP
6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ® Deep Trench ❑ Wide Trench ❑ Seepage Pit
Waiver request for:
Expedited review requested: ❑
Distance:
By applying for this entitlement, this property is subject to inspection by municipal On-site staff
to verify the accuracy of the information provided.
COSA Fee $,55 O Waiver Fee $ _
Date of Payment
� / .5 / � 7. 3 Date of Payment
COSA # DSC 2 3 12.E Waiver #
COSA Application.doc
COSA Checklist.docx
COSA Checklist
Legal Description: VALLI VUE ESTATES #2 BLOCK 2, LOT 15 Parcel ID: 015-322-43
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____
A. WELL DATA - PUBLIC &/OR CLASS “A” WATER
Well log is filed with Onsite (or attached)
Date drilled Total depth ft
Cased to ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) in.
Date of flow test for COSA
Static water level at beginning of test ft.
Well production at time of test gpm
Water storage tank volume NA gallons
Well disinfected for coliform test? Yes No
Coliform bacteria is Negative
Nitrate mg/L Nitrate less than MRL (ND)
Arsenic ug/L Arsenic less than MRL (ND)
Collected by
Date
Comments __________________________________________________________________________________
B. TANK DATA
Measured operating fluid level in septic tank NEW
Date of pumping NA – NEW 1500 STEP TANK
Required maintenance completed, if AWWTS
Comments:
C. LIFT STATION
Required maintenance completed
Age of lift station NA - NEW years
Lift station material HDPE
Comments:
D. ABSORPTION FIELD DATA – UNDOCUMENTED SYSTEM DOCUMENTED IN 2018 PER MOA FILE – INSPECTION REPORT (IR)
Which system tested (date installed) 10/24/1997
ALL standpipes present per record drawing
Total measured depth from grade 6.2 ft (max)
Measured depth to pipe invert from grade 2.6 ft (min)
N/A – pressurized field.
Per record drawings, field is insulated.
Monitor tubes (MT) go to bottom of effective. (ED)
If not, state depth into effective 3’ & 3.5’ (MT3 / MT4)
Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced gallons date
Any rejuvenation treatment (past 12 months) N
If yes, enter date
Adequacy test date 5/1/2023
Results Pass
Fluid depth prior to test 19 / 7 in (MT3 / MT4-IR)
Water added 700 gal
New fluid depth 36 / 36 in (UP INTO LATERALS)
Elapsed time 1350 min
Final fluid depth 19 / 5 in (MT4 2” lower than start)
Absorption rate 600 gpd
FIELD STATUS – POST RECOVERY
Effective depth (per record drawings) 48 in (4’ ED)
Effective depth used 31 / 11 in (MISSING ED & FINAL
FLUID DEPTH OF EASTERN TRENCHES MT3 & MT4)
Effective depth remaining 17 / 37 in
Comments/Deficiencies: Tested the eastern 2 trenches 1” up into / to the field laterals. The western trenches were near
the top of the ED. Septic system is operating in the top portions of the effective depth (ED).
COSA Checklist.docx
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) - NA
Septic Tank/Lift Station on Lot > 100’
Yes if No ft
Neighboring Tank > 100’ Yes if No ft
Absorption Field on Lot > 100’ Yes if No ft
Neighboring Absorption Fields > 100’
Yes if No ft
Community Sewer Main > 75’ Yes if No ft
Community Sewer Manhole/Cleanout > 100’
Yes if No ft
Private Sewer/Septic Line > 25’ Yes if No ft
Holding Tank > 100’ Yes if No ft
Animal Containment > 50’ Yes if No ft
Manure/Animal Excreta Storage > 100’
Yes if No ft
N/A – Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required)
Building Foundations > 10’ Yes if No ft
Tank to Property Line > 5’ Yes if No ft
Field to Property Line > 10’ Yes if No * ft
Water Main > 10’ Yes if No ft
Water Service Line > 10’ Yes if No ft
Surface Water > 100’ Yes if No ft
Wells on Adjacent Lots:
Private Wells > 100’ Yes if No ft
Community Wells > 200’ Yes if No ft
If tank or field is under driveway comment below
F. ENGINEER’S COMMENTS
*Western absorption trench was shown to be approximately 11’ from property line by Walataka a Registered
Land Surveyor in 2018 & shown in MOA file. Walatka performed a recert on 6/8/23 with the same results
and this survey is attached.
G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm FIRST WATER CONSULTING Phone 907-350-9566
Engineer’s Printed Name CURTIS HUFFMAN, PE Date 6/8/2023
Comments: This investigation was completed in compliance with MOA guidelines, regulations,
and best industry practices / methods. The assessment of the condition of the well and septic
applies only to the conditions as of the day tested. The flow and absorption rates may change
due to subsurface conditions that may not be observed from the surface, changes in land use,
local soil characteristics, groundwater levels that may fluctuate during the year, quality of
construction (workmanship & materials), the water usage of the family being served by the
system and maintenance. The operational life of all well and septic systems are subject to
these various and dynamic characteristics and are outside the control of the evaluator of the
well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory
for current or future occupants or guarantee that no unseen encroachments, deficiencies or
discrepancies exist can be given by First Water Consulting &
6/8/23
)5(
• Gi f3<:
• .- , Municipality of Anchorage/ ci
On-Site Water and Wastewater Program ,
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
ci
Parcel I.D. 015-322-43 Expiration Date: '-- br C
1. GENERAL INFORMATION
Complete legal description _VALLI VUE ESTATES #2 BLK 2 LT 15
Location (site address) _6201 CORNER TREE DR ANCH AK
Current Property owner(s) _ROBERT HOWARD Day phone
Mailing address _SAME
Real Estate Agent Day p •rfe6 8 9 /0 77
1
N RUSE! A-
2. TYPE OF DWELLING:
® Single Family (w/wo ADU) a MAY 0 201$ 3
❑ Duplex �a ___y
❑ Multiple Dwellings (Single Family and/or Duplex) 2O�'i` s 8 L°'
3. NUMBER OF BEDROOMS: 4
4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Individual Well ❑ Individual
Individual Water Storage ❑ Holding Tank ❑
Community Class A Well ® Community ❑
Public Water System ❑ Public Sewer ❑
WaiverNariance request for: Distance:
Received by: 7014 Date: c5////i/
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ ggl.Cao Waiver Fee $
Date of Payment 51q /i Date of Payment
Receipt Number a Zi(O.vl Receipt Number
COSA# 056/n/QO Waiver#
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm MIKE N ANDERSON,P.E. Phone 727-8864
Address 4661 NATRONA AVE.
Engineer's Printed Name MIKE N ANDERSON,PE Date 5/8/18
•
•
o
r✓I ° 4 yl`,'t
rte' ^o,
(•'�ao ooan oo -oo I'
°o+ara0000,l
6. DSD SIGNATURE A..`' ` -
�1p L „a ve. yo0000
11( rte. ;� ;i;r�s-• ;
bedrooms. �x':,•, C .
'4:
System #1 Approved for ° •
Y
4
System #2 Approved for bedrooms. u: : ( !�°
Disapproved.
Conditional approval for bedrooms, with the following stipulations:
-cY OF,rw/5G
ON-SITE
WATER AND rn
: WASTEWATER o
fi PROGRAM R:
C O\l\C^
By: �^--� �/� Original Certificate Date: ,7 � "(
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The
Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
• COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet 10-1O.12.doc
If more than 1 septic system is on the lot:
COSA Checklist# of
Structure served by this system _
Certificate of On-Site Systems Approval Checklist
Legal Description: VALLI VUE ESTATES #2 BLK 2 LT 15 Parcel ID:_015-322-43
A. WELL DATA
Well type A If A, B, or C provide PWSID#210605 Well Log (Y/N)
Date completed Sanitary seal (Y/N)Y Wires properly protected (Y/N)Y
Total depth _ft. Cased to ft. Casing height (above ground) +
FROM WELL LOG AT INSPECTION
Date of test
Static water level ft. ft.
Well production g.p.m. g.p.m.
WATER SAMPLE RESULTS:
Coliform colonies/100 mL Nitrate _mg/L
Arsenic: ug/L Date of sample: Collected by:
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material STEEL Date installed 10/18/97-10/24197
Tank size 1500 gal. Number of Compartments 2 Cleanouts (Y/N) Y
Foundation cleanout(Y/N)Y Depression over tank (Y/N) N High water alarm (Y/N) N
Date of pumping Pumper TANK EMPTY
C. ABSORPTION FIELD DATA—SYSTEM WAS PRE-SOAKED PRIOR TO TESTING.
Date installed 10/18-24/97 Soil rating (SF/BED) 362 System type DEEP TRENCH
Length 181 ft. Width 2.0 ft. Gravel below pipe 4.0 ft.
Total depth 7-7.5' ft. Eff. absorption area 1448 ft2 Monitoring tube Y Depression over field N
Date of adequacy test 5.6.2018 Results (Pass/Fail) PASS For 4 bedrooms
Fluid depth in absorption field before test 0 in. Water added 800+gal. new depth 12 in.
Elapsed Time: 1440 min. Final fluid depth 0 in. Absorption rate >__800_g.p.d.
Any rejuvenation treatment(past 12 mo.) (Y/N &type) N If yes, give date
D. LIFT STATION
Date installed 10/18-24/97 Size in gallons 1500 Manhole/Access (Y/N) Y
"Pump on" level at 36 in. "Pump off' level at 28 in. High water alarm level at 40 in.
Datum TANK BOTTOM Cycles tested 12 Meets alarm&circuit requirements? Y
E. SEPARATION DISTANCES
WELL ON LOT TO:
Septic tank/lift station on lot 100'+ On adjacent lots 100'+
Absorption field on lot 100'+ On adjacent lots 100'+
Public sewer main 75'+ Public sewer manhole/cleanout 1001+
Sewer/septic service line 25'+ Holding tank 100'+
Animal containment areas 50'+ Manure/animal excrete storage areas 100'+
SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 44 (0+ Property line 5'+ Absorption field 5'
Water main 10'+ Water service line 10'+ Surface water 100'+
Wells on adjacent lots 100'+
ABSORPTION FIELD ON LOT TO:
Property line 10'+ Building foundation 10 Water main 100'+
Water Service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+
Curtain drain 50'+(None Known) Wells on adjacent lots 100'+
F. COMMENTS
SYSTEM WAS DESIGNED AND INSTALLED BY OTHERS, THIS INSPECTION REPORT IS ONLY DOCUMENTING WHAT WAS
DISOVERED IN THE MOA FILES AND ON-SITE.
G. ENGINEER'S CERTIFICATION \ � "s
P `
I certify that I have determined through field inspections and o • r
review of Municipal records that the above systems are inei *: 49TH '' °•.:
conformance with MOA COSA guidelines in effect on this date. /1,
Engineer's Printed Name MIKE N. ANDERSON,PE / ..MICHAEL N. ANDERSCN
Cci•. CE-9469
Date 5/8/2018 lt ,pf,••• 5� �.•`
1�`u fffSsi�� �
COSA canary sheet_2-6-15.doc
N860t Lot 18 1 8470T
Q8 05 W 51.48 Lot 7
10' Utility Ease
ment'l
0 c
0 de
I 0 0
i 0
I
I Wood fence (typ)
0 t
I
I
Lot 16
C) I
� 1 s
00 b 0 0 Chain link fence (typ c.r�
cr)
i U),
eptic vent (typ)
CD
CD I ��
CD dQ
o I 'UP
CD LOT 15 °
o I F SCALE..
V= 30
Z � I
I
(I a n hole O .°
p �`L e
��W
3 (; p
4"
M
c� C °•o .°
� � I �o
u o
3 0
aD a
�
1.2 OH v
Q)
o N o
Io DRIVE
.*.r CORNER RNER TREE
I ii
i 4�
N88019102"E 131.00
Lot 14 RECERTIFIED 6-05-23
AS-BUILT NO CORNERS SET THIS DATE
`'I hereby certify that I have performed a Mortgagee's inspection
OF ,C' ' ` of the following described property: LOT 15, BLOCK 2,
�. • ' " ' - ��Q VALLI VUE ESTATES UNIT No. 2
40 49th 04 � Anchorage Recording Precinct, Alaska, and that the
00 improvements situated thereon are within the property lines
00 00 and do not overlap or encroach on the property lying
• • • adjacent thereto, that no improvements on the property lying
� •" iizobeth L. Wolatka .' ,o / adjacent thereto encroach on the premises in question and
�`p,� 803fi - LS �-� AW that there are no roadways, transmission lines or other
rF • J .�. visible easements on said property except as indicated
�Fa • . " . • '�,o ,W hereon.
� Dated at Anchorage, �oF t vP e Alaska
ESS I ONA �,
, this 16th day of MARCH , 2018.
EASEMENTS OF RECORD, OTHER THAN \%%Vt
THOSE SHOWN ON THE RECORDED FB 23-1, pg 18 3 FRED WALATKA & ASSOCIATES
PLAT ARE NOT SHOWN HEREON Recert 5-01-18 BEEngineers and Surveyors
UNLESS OTHERWISE NOTED. FB 18-2, pg 32 907-248-1666
This drawing is a representation of conditions found at the time the mortgage location survey was performed. This document does not constitute a boundary
survey and is subject to any inaccuracies that a subsequent boundary survey may disclose. The information contained on this drawing shall not be used to
establish any fence. structure or other improvements. This drawing shall only be used for a single property transaction. Use of this drawing by the original
client or by others at a later date without the consent of Elizabeth L. Walatka is a violation of Federal Copyright law. Unless gross negligence is discovered,
the liability extent of the preparer is limited to the amount of fees collected for services in preparation of this product.
ot 18
N86°08'05"WL 51.48 / 8470T
,. ._,_,, Lot 17
10' Utility Easement\ _
0 °
0
Wood fence(typ)
°
r'
Lot 16
OLo
L y b ° Chain link fence(typ �Q°
rn
eptic vent(typ) ��
CD
o 0
oy LOT 15 `.90
z
\ SCALE: 1"= 30'
•
peptic Tank , �o 1g.
y as ‹ol"cn
toe03 0 d
-6 w Hca ^r,..\y ..
= yrs ° G,`�� V,1`Y yY•;�,n! :�'€'`%
.ti�i.. c
o
z , `*X
BScy :p
3
.%:: .
O a t .. " O.
O ae . rL.� . h
2.0 OH :,;
V
O O
N
Zt
.5' ih0 CORNER TREE DRIVE
N88°19'02"E 131.00
Lot 14 RECERTIFIED 5-1-18
AS-BUILT O CORNERS SET THIS DATE
'fi.,%....%:•N OF .A 1 1 I hereby certify that I have performed a Mortgagee's inspection
• • •,4 j of the following described property: LOT 15. BLOCK 2.
;9 I VALLI VUE ESTATES UNIT No. 2
I ow�P•• • •
S-r
I° C,,. 49th �, •• y //
t /\ •., / Anchorage Recording Precinct,Alaska,and that the
/ improvements situated thereon are within the property lines
/L L� �� , and do not overlap or encroach on the property lying
/ .. �. is^V...tr- Si adjacent thereto,that no improvements on the property lying
//3, Elizabeth L. Wolotko:its/ adjacent thereto encroach on the premises in question and
""<,..,• 8036 - LS Jam' that there are no roadways,transmission lines or other
I1p� ,• 5 visible easements on said property except as indicated
0
hereon.
A�'0 ss oNp'- �'Pa Dated at Anchorage,Alaska
EASEMENTS OF RECORD,OTHER THAN i%X\\ N�` this 16th day of MARCH ,2018.
THOSE SHOWN ON THE RECORDED 5-3--/1.7:, FRED WALATKA&ASSOCIATES
PLAT ARE NOT SHOWN HEREON FB 18 232 BE Engineers and Surveyors
,
UNLESS OTHERWISE NOTED. pg 907-248-1666