HomeMy WebLinkAboutVALLI VUE ESTATES #2 BLK 2 LT 19Onsite File
Valli Vue
Estates #2
Block 2
Lot 19
#015-322-39
4-bedroom approval is for septic tank
only. Drainfields are each sized for up
to 3-bedrooms.
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
ht,p:11w%,vw.muni.arg1onsfte
Permit Number: OSP211244
Work Type: SepticTank Upgrade
Tax Code Number: 01532239000
Site Legal Address: VALLI VUE ESTATES #2 BLK 2 LT 19 G:2538
Site Mailing Address: 6266 WEST TREE DR, Anchorage
Owner: MANN JASON R &
Design Engineer: GARNESS ENGINEERING GROUP LTD
This permit is for the construction of:
Effective Date
Expiration Date
Lot Size in Sq Ft:
Total Bedrooms:
ry
Department
6/29/2021
6/29/2022
20036
E-1 Disposal Field 21 Septic Tank 0 Holding Tank 0 Privy 171 Private Well 171 Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15-65. Provide notification by calling (907) 343-7904 (2417).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
AW,
Special Provisions:
1) 4 -bedroom approval is for septic tank only. Drainfields.are each sized for up to 3 -bedrooms.
2) The water service line shall be located at time of construction to confirm minimum 10 ft separation to septic
system.
Received Bw
Issued By:
Date: L
Date: -) I
0�
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 015-322-39
Property owner(s) TANI KRON Day phone 907-830-1007
Mailing address 6266 WEST TREE DRIVE *ANCHORAGE, AK
Site address 6266 WEST TREE DRIVE *ANCHORAGE, AK
Legal description (Sub'd., Block & Lot) VALLI VUE ESTATES #2; BLOCK 2, LOT 19
Legal description (Township, Range & Section)
Lot Size
Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
❑
Initial ❑
Single Family (SF)
(w/wo ADU)
Septic Tank
7
Upgrade Z
(D) ❑
Holding Tank
❑
RenewalDuplex
❑
Multiple Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION
INCLUDES A WAIVER REQUEST FOR:
N/A
Distance: -
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: 22 r Waiver Fees:
Date of Payment: 5 a0 Date of Payment:
Receipt Number: G 6 `i 7 5 G Receipt Number:
Permit No. C� P 2-1 1 ?_9'- Waiver No.
G:\Development Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211244, Rebecca Carroll, 06/29/21
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211244, Rebecca Carroll, 06/29/21
f'OT A' PART
t
I
..
Municipality of Anchorage Page
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: 5't,,,/~ ¥0 ¥c~0" PID Number:
Name:
~ch~l ~o~ Wastewater System: D New ~ Upgrade
Addres':6~ ~ ~ee D~ A. c4~ ~/< ~/~ ABSORPTION FIELD
Phone: ~y~.3e~7 IN°'°f~dr°°~: DDeepTre~ch ~ Shallow Trench DBed ~Mound DOther
LEGAL
DESCRIPTION
} * ~ GPD/Sq. Ft.
LOt: Block: Subdiv~ion: ~ ~ Depth to pipe bottom from original grade: Gravel depth beneath pipe
Township: I Range: I Section: Fill added above original grade; Gravel length:
I
I
~'~ Ft, ~ Ft.
Gravel width: Number of lines: ~Dista~ce between lines:
WELL:
New
Upgrade
Classification (Private, A,B,C): Totat Depth: Cased To: Total absorption area: Pipe material:
Driller: Date Drilled: StaticWaterLevel: Installer: Date installed:
Yield: GPM IPump Set at: Ft. ]Casing Height Above Ground:Ft. TANK
SEPARATION DISTANCES ~septic ~ Ho[ding ~ S.T,E,P.
To Septic Absorption Lift Holding 'ublic/Private Manufacturer: Capacity in gallons:
FrO~ Tank Field Station Tank Sewer Lines
Material: ~ ~ ~/ Number of Compa~ments:
su,.ce LIFT STATION ~.~
Water ! ~ ~Oo' ~ t~
Lot Size in gallons: ~ Manufacturer:
Cu~ain Pump Make & Model I Electrical Inspections performed by:
I
Remarks: ~y~ m~(/~ p~ BENCH MARK
Location and Description:
' ~ Assumed Elevation:
Reviewed and approved b~~~
7g-013 (R~. 9191) MOA 25
PERMIT NO: SW940406
PAGE 2 OF 2
PID NO: 01532239
LOT 19, BLK. 2
VALLI VUE #2
44' LONG x 5' WIDE
DRAINFIELD
SWING TIES
NEW 1000 GALLON
SEPTIC TANK
PLAN VIEW
SCALE: 1" = 30' - 0"
!FROM: COR "A"
O: ....
.T.C.O., E. 17
.T.C.O. 'F 22.5
DBL. C.O. 'G" 27
C.O. "H"
"B .... C ....D"
24
26
25
60 20
47
M.T. "1"
C.O. "d"
86 45 64
103 61.~6
1000 GALLON ~__INV
SEPTIC TANK 94.4'
-- BOTTOM DRAINFIELD @ 89.4'
PROFILE VIEW
VERT. SCALE: 1" [] 5' -0"
~- T.H.#2 M.T. DRYAT 82.0'
LOT 19, BLK 2, VALLI VUE EST #2
SEPTIC SYSTEM UPGRADE
AS-BUILT INSPECTION REPORT
FLATTOP TECHNICAL SERVICES
14530 ECHO STREET
ANCHORAGE, ALASKA 99516
ISCALE: AS,SHOWN
DRAWN BY TFM
NOVEMBER, 1994
PAGE 1 0~ 1
MI/NICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES ~,'.J~ I,/~'q[ ~ [ZJOI t~/Iq
P.O. BOX 196660, 825 "L" STREET, ROOM 502 ~KZ~i/.Z/~
ANCHORAGE, ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGP~ADE) PERMIT
PERMIT NUMBER:SW940406
DESIGN ENGINEER:FLATTOP TECHNICAL SERVICES
OWNER NAME:GOODE MICHAEL R & VICKI L
OWNER ADDRESS:6266 WEST TREE DR
ANCHORAGE, AK 99516
DATE ISSUED:10/19/94
EXPIRATION DATE:10/19/95
PARCEL ID:01532239
LEGAL DESCRIPTION: VALLI VUE ESTATES #2 BLK
T 19
2 L
LOT SIZE: 20036 (SQ. FT.)
NIrMBER OF BEDROOMS: 3 THIS PEP, MIT: 3
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 (24 HOURS)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
RECEIVED
ISSUED BY: ~~~~ C
DATE:
THEODORE F. MOORE, P.E.
PH: (907) 345-1355
OP T] CHNiC A, ::SE
CIVIL & ENVIRONMENTAL ENGINEERING * ENERGY CONSERVATION & ANALYSIS
14530 ECHO ST.
October 12, 1994 ANCHORAGE, ALASKA 99516
M.O.A. DHHS
P.O. Box 19-6650
Anchorage, AK 99519
Dear Sirs:
The purpose of this letter is to provide the required design narrative in support of our application for a
permit to upgrade the wastewater disposal facilities on Lot 19, Block 2, Valli Vue Estates, Unit//2, located
at 6266 West Tree Drive. The existing soil absorption trench failed a recent adequacy test. Soils logs,
perc test results, sieve analysis results, a site plan, design drawings and specifications are enclosed for
your review.
The proposed system will be constructed in the vicinity of test hole # 2A. As can be seen from the
soil logs for this and adjacent test holes, the native material below 9.5 feet is a uniform fine sand with a
measured perc rate of less than one minute per inch. The enclosed laboratory sieve analysis of material
removed from the perc test hole shows that it is properly classified as SP, and therefore there in no need to
install an imported sand filter. Using the soil application rate of 1.2 gpd/sq, ft. specified in the
wastewater ordinance for soils with measured pere rates of less than 5 minutes per inch, this 3 bedroom
residence requires a total absorption area of (3 x 150)/1.2 = 375 square feet. The proposed 5' wide
drainfield design with 3 feet of sewer gravel beneath the horizontal distribution pipe has a total effective
absorption area of 377 square feet.
The topography in the area of the proposed construction slopes downwards towards the east at
approximately 2%. The ground surface at test hole #2 is approximately one foot lower than at T.H. #2A.
The proposed project will have no impact on present or future water supply and wastewater disposal
systems serving adjacent properties, nor will it have any impact on reserved space/surface and subsurface,
or on drainage. This subdivision is served by a community water system.
Please give me a call at 345-1355 if you have any questions on tlfis submittal.
Sincerely,
Ted Moore, P.E.
LOT 12, BLOCK 1
SPRING FOREST S/D
HOUSE
LOT 20, BLOCK 2
LOT 19, BLK. 2
VALLI VUE #2
,; T.H.#3 T.H.
OLD 1000 GAL.
SEPTIC TANK
~#2A ?,,~$ EPTIC TANK
NEW 44' LONG
5' WIDE DRAINFIELD
-W. 3' GRAVEL BELOW
HORIZ. DIST. PIPE
SEPTIC .__~
SYSTEM~
LOT 18, BLOCK 2
NOTE: HOUSES IN THIS
SUBDIVISION ARE SERVED
BY A COMMUNITY WATER
SYSTEM. N
20 0 20 40 60 80 100
FEET
LOT 19, BLK. 2, VALLI VUE EST. #2
SEPTIC SYSTEM UPGRADE
SITE PLAN
FLATTOP TECHNICAL SERVICES r 1 INCH = 50 FEET
14530 ECHO STREET I DRAWN BY TFM
ANCHORAGE, ALASKA 99516 OCTOBER, 1994
NOTE: THIS IS NOTASURVEYED PLAT.
ALL LOCATIONS SHOWN ARE APPROXIMATE.
44~ "A" 4" D-3034 FROM
SEPTIC T~I~ K
4" PERF PIPE (F-810) ~ 'A" EXCAVATION
PLAN VIEW
SCALE: 1" = 10' - 0"
MONITOR TUBE
ORIGINAL GROUND
1ACKFILL
FABRIC
F-810 PERF PIPE
3.5' SEWER GRAVEL
(3.0' BELOW PIPE)
SECTION 'A - A"
SCALE: 1" = 5' - 0'
LOT 19, BLK 2, VALLI VUE EST#2
SEPTIC SYSTEM UPGRADE
PLAN AND CROSS-SECTION
FLATTOP TECHNICAL SERVICES
14530 ECHO STREET
ANCHORAGE, AK, 99516
SCALE: AS SHOWN
DRAWN BY: TFM
OCTOBER, 1994
Flattop Technical Services
14530 Echo Street, Anchorage, AK99516
Phone (907) 345-1355
Lot 19, Block 2, Vaili Vue Estates, Unit g2
6266 West Tree Drive
Wastewater disposal system installation
Specifications
1.0 General:
1.1 The scope of the project consists of abandonment of an exi~sting septic tank and soil absorption
trench and installation of a new 1000 gallon septic tank followed by a 44 foot long, 5 foot wide soil
absorption dralnfield with 3 feet of sewer gravel beneath the horizontal distribution pipe.
1.2 Construction shall be as depicted on the approved site plan and design drawings. Minor
deviations from these drawings may be allowed or required by the engineer conducting the inspections.
All c. onstmction procedures and material specifications shall conform with Municipal and State
reqmrements. All separation distances shall be in conformance with Municipal requirements, unless
specifically waived.
1.3 The contractor shall be responsible to obtain any necessary utility locates, and to work around any
buried utilities.
1.4 The contractor shall provide adequate cover material and rough grading over all system
components to ensure that proper drainage is achieved after settlement and that there are no residual
depressions. Insofar as possible the contractor shall minimize damage to trees and existing lawn areas.
1.5 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading after
the soil is compacted, as well as placement of topsoil and reseeding all areas disturbed by the construction.
2.0 Septic Tank:
2.1 Unless inspection by the engineer confirms that the existing tank is still in good condition, the
existing septic tank is to be properly abandoned by thoroughly pumping, removing its top and backfilling
with soil.
2.2 The new 1000 gallon, 2 compartment septic tank shah be Municipally approved and shall be set
level on undistur[~ed soil. Each compar~anent shall be equipped with a watertight manhole cover and a 4"
cleanout. If the tank is buried less than 4 feet, it shall be insulated with 2 inches of approved burial type,
rigid insulation.
2.3 All pipe connections to the tank shall be equipped with waterproof mechanical couplings. The
waste line from the residence to the septic tank shall have a minimum slope of 1/4"' per foot, and the waste
llne between the tank and the soil absorption system shall have a minimum slope of 1/8" per foot. A
cleanout shall be installed within 5 feet of the building foundation, and a double cleanout shall be installed
within 5 feet downstream of the septic tank.
3.0 Soil absorption system:
3.1 The soil absorption system shall be constructed by excavating a 5' wide trench to a total depth of
· approximately 13 feet below the elevation of the original ground in the vicinity of test hole #2A.
3.2 The bottom of the excavation shall be level. Any compacted or smeared surfaces shall be raked to
allow proper infiltration. Sand for leveling or serving as filter material shall comply with Municipal
specifications.
3.3 A total of 3.5 feet of approved sewer gravel shall be placed in the bottom of the excavation with
the perforated distribution pipes laid level such that the pipe inverts are no less than 3.0 feet above the
bottom of the sewer gravel. Sewer gravel shall be 0.5" - 2.5" screened gravel, with less than 3% passing
the g200 sieve.
3.4 Monitor tubes and cleanout pipes shall be of 4" diameter and installed in the locations shown on
the design drawings. The portion of the monitor tube extending tlu:ough the sewer gravel shall be
perforated.
3.5 Approved filter fabric shall be placed over the entire top surface of the sewer gravel before
backfill.
3.6 The top surface of the cover material shall be raised a minimum of 12 inches higher than the
surrounding terrain to allow for subsequent settlement, and shall be graded to smooth contours. Fill
slopes shall be no steeper than 3:1.
3.7 Unless specifically agreed otherwise the homeowner shall be responsible for arranging to have the
site finish graded after the backfill material has stabilized, and for placement of adequate topsoil and seed
to promote rapid revegetation of all areas disturbed by the construction.
4.0 Inspections:
4.1 A total of 4 engineering inspections will be required during the course of the project: (1) initial
stakeout with the contractor to establish the location of the system and to discuss the plans, specifications
and construction procedures, (2) after the native material has been excavated to expose the infiltrative
surface to ensure that it is level and at the right elevation, and conforms with the soil test information, (3i
after the sewer gravel is in place and the distribution pipes have been laid and connected up to the septic
tank, but prior to placement of the filter fabric, and (4) after rough backfill and grading is complete. The
septic tank requires one inspection after it is set level and the piping connected, but prior to backfill. This
inspection may be incorporated with any of the above inspections.
4.2 The instbller shall coordinate the timing of the inspections with the engineer sufficiently far in
advance to ensure the availability of the engineer.
TEST HOLE
LEGAL DESCRIPTION:
DATE PERFORMED:
PERFORMED FOR;
DEPTH
(feet)
1-
COMMENTS:
FLATTOP TECHNICAL SERVICES
14530 ECHO ST.
ANCHORAGE, ALASKA 99516
SOILS LOG -- PERCOLATION TEST
Lot 19. Block 2. Valli Vue Estates. Unit #2
October 6:1094
Rick Goode
Pt
ML Gray silt, fill
Pt
SM Reddish sandy loam
ML Gray silt, dense, dry. cohesive clumps
Some cobbles and boulders
scattered damp sand seams @ 10'
large bpulder at 10.5'
SLOPE
Depth to Groundwater Date
No Groundwater 10/6~)6
q
Clock Net Time Porcometer Not Drop
Date Reading Time (minutes) Reading (inches)
PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN FT AND FT
Soil not suitable for construction of an on-site soil absorption system. No monitor tube set.
PERFORMED BY FLA'FrOP TECHNICAL SERVICES. I ~',.z.~ ff~'~..,~(._
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES iN EFFECT ON THiS DATE.
CERTIFY THAT THIS TEST WAS PERFORMED IN
DATE: tO / /"~[ ~ ~
TEST HOLE
LEGAL DESCRIPTION:
DATE PERFORMED:
PERFORMED FOR:
DEPTH
(feet)
11-
12-
13-
FLATTOP TECHNICAL SERVICES
14530 ECHO ST.
ANCHORAGE, ALASKA 99516
SOILS LOG -- PERCOLATION TEST
Lot 19. Block 2, Va[Ii Vue Estates. Unit #2
October 6, 1994
Rick Ooode
Pt
SM Reddish sandy loam
ML Brown silt, dense, cohesive near top
becoming looser with depth
SP/SM Fine gray sand
SLOPE
Depth to Groundwater Date
No Groundwater 10/6i96
Monitor lube dry 10/12/94
... ..
SITE P~N
14-
COMMENTS:
Transition to SP, Uniform
fine sand, below 13 feet
Clock Net Time Percometer Net Drop
Date Reading Time (minutes) Reading (inches)
PERCOLATION RATE
(minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN FTAND FT
See log for T,H #2A for perc test results
PERFORMED BY FLATTOPTECHNICALSERVICES. I '~'"~,~. ~
ACCORDANCE WITH ALL STATE AN D MUNICIPAL GUIDELINES IN EFFECT ON THiS DATE.
CERTIFY THAT THIS TEST WAS PERFORMED IN
DATE: ~0 / [ ~. /' c~
lTEST HOLE# 2Al
LEGAL DESCRIPTION:
DATE PERFORMED:
PERFORMED FOR:
FLATTOP TECHNICAL SERVICES
14530 ECHO ST.
ANCHORAGE, ALASKA 99516
SOILS LOG -- PERCOLATION TEST
Lot 19. Block 2. Valli Vue Estates. Unit #2
October 6:1994
Rick Goode
DEPTH
(feet)
Pt
SM Reddish sandy loam
ML Brown silt
SP/SM Fine gray sand
Transition to SP, Uniform
fine sand below 9.5 feet
B.H.
SLOPE
Depth to Groundwater Date
No Groundwater 10/6/96
o,
Clock Net Time Percometer Net Drop
Date Reading Time (minutes) Reading (inches)
10/ltl 12" Presoak 4:12 27 1/2
4:14 dry
4:15:30 21
4;20 29
4:21 1 23 6
4:22 1 20 3
4:23 i Dr~ 3
16-
18-
PERCOLATION RATE <i (minutes/inch) PERC HOLE DIAMETER '6"
TEST RUN BETWEEN 11.0 FTAND il.s FT
COMMENTS: Perc test was conducted approximately midway between T.H.'s #2 and #3. The clean sand stratum was encountered at a shallower
depth than in the other test holes. Recommend constructing soil absorption system in vicinity of T.H. #2A. See sieve analysis of material from per,
I . _'~,.~ '~'~'~._ CERTIFY THAT THIS TEST WAS PERFORMED IN
PERFORMED By
FLATTOP TECHNICAL SERVICES.
ACCORDANCEWITHALLSTATEAND MUNICIPALGUIDELINES iN EFFECTON THiS DATE. DATE: ~O t//~-.j ~
TEST HOLE # 3
LEGAL DESCRIPTION:
DATE PERFORMED:
PERFORMED FOR:
FLA'rroP TECHNICAL SERVICES
14530 ECHO ST.
ANCHORAGE, ALASKA 99519
SOILS LOG -- PERCOLATION TEST
Lot 19. Block 2. Valli Vue Estates. Unit #2
October 6, 1994
Rick Goode
DEPTH,
(feet)
1
Pt
SM Reddish sandy loam
Iv~ Gray/brown somewhat sandy silt
Soft digging
SP/SM fine sand
scattered
clumps of IvlL
SLOPE
Depth to Groundwater Date
No Groundwater 10/6/96
Monitor tube dry 10/l 2~94
...,
SITE P~N
.Becomes clean SP
below 13', however
there are scattered
clumps of ML
Clock Net Time Percometer Net Drop
Date Reading Time (minutes) Reading (inches)
PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN FTAND FT
COMMENTS:
PERFORMED BY FLATTOP TECHNICAL SERVICES. l
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE.
CERTIFY THAT THIS TEST WAS PERFORMED IN
I
J.U/,1Z/I~ Z,~:Z:" ~'9o"r .522 ,3403 R&M CONSULTANTS
' ' LABORATORY TEST REPORT
CLIENT/PROJECT: Flattop Technical Services / Valli Vue
TEST ON: Ta~st Hole
SOURCE: Valli Vue Subdivision SUBMI1TED BY: Client
SAMPLED FROM: Test Hole #2A DATE SAMPLED: ~
LOCATION 12 va, .. DEPTH: 11 ft.
~003/003
R&M PROJECT: 45107,~
LAB NO.: 4282
FIELD NO.= N/A
DATE REPORTED: 10/11/94
DATE RECEIVED: 10/10/94
BRAIN SIZE DISTRIBUTION
SIEVE SPEC.
5" % + 10
4' 6+3
3e % GRAVEL
2" %SAND
I 112 '
%SILT
1" % CLAY
3/4"
1/2'
3/8"
//4
//8 CLASS
#10
~30
~40
~so
~60
~10o
~200 6.0
,02MM
.O05MM
.O02MM
CLASSIFICATION COMPACTION
UNIFIED AASHO
OPTIMUM MOISTURE:
MIN. DRY OENSI"C~'.
0
94
~, FRACTURE;
NATURAL DENSITY=
NATURAL MOISTURE:
WEIGHT LOOSE:
SP
GRaJN SIZE DISTRIBUTION CHART
~;: ;'7.' ,' ",~,.,';., , '; :;,, .,~ ,.-/- .- i ,.,,- T T
GRAIN SIZE Irmn)
TOTAL WT. TESTED'. 518 GMS.
~)EtE'~EfllOUS MAT.
COARSE SPEC F~E Si~EC
ORGANIC CONTENT
L.A, ABRASION LOSS:
REMARKs:
Tested By:. CLF Checked BV: S JO
GRE~..ER ANCHORAGE AREA BOP.. IIGH
Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
NAME ~f/¢0.-t"//:;'.,4~ ,¢lc)eK; MA,L,NG ADDRESS ~'~ r+ 7¢'/5 qCb-o? P,ONE :~'¢,1- 5-¢o(,/
SEPTIC TANK: . _~
DISTANCE /'~ /~.~_ ~""~"~"-'~ R ~
FROM WELL ~//,~'~(~MANUFACTURE ~)~2.~' MATERIAL cNoUMMpBAERRTOMFENTS ~
INSIDE LENGTH / INSIDE WIDTH / LIQUID DEPTF~"'~ LIQUID CAPACITY[~'~ALLONS.
TILE DRAIN FIELD:
DISTANCE FROM WELL ATION __2~ NEAREST LOT LINE
ABSORPTION AREA ,~'/'~0 SQ, FT. LENGTH OF EACH LINE
..~,~.,~,...f¢ ~ DEPTH OF FILTER
DEPTH: TOP OF TILE TO FINISH GRADE ~J~/'(~ MATERIAL BENEATH TILE_ ~ ¢~) IN. ABOVE TILE
TOTAL L ENG T H/4,//~
OF LINES
IN. TOTAL EFFECTIVE
TYPE _"--7 ~' v--L~ CONSTRUCTION DEPTH
BUILDING NEAREST NEAREST SEPTIC SEEPAGE
FOUNDATION LOT LINE , SEWER LINE , TANK__ SYSTEM_
CESSPOOL OTHER SOURCES
APPROVED_ DISAPPROVED REMARKS
DISTANCE FROM:
DISTANCES: ~ --
PIPE MATERIAL:
LOT SLOPE:
Form LQ-032
DIAGRAM OF SYSTEM
GR£]-".'Er ANCHORAGE AREA BO )UGH
DEPARTMENT OF ENVIRONMENTAL QUALITY
3330 'C" STREET ANCHORAGE. ALASKA 99503
SEWAGE DISPOSAL SYSTEM APPLICATION AND PERMIT
LEGAL DESCRIPTION ,'
DRAIN FIELD ., OTHER
TO BE INSTALLED BY
NOTE= THIS PERMIT IS NOT VALID WITHOUT SOIL TEST
COMPLETION DATE ANTICIPATED
FINAL INSPECTION ;~4 HOUR NOTICE REQUIRED, BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION....
SEEPAGE PiT .
· DRAIN FIELD
ALSO CONSEDER AREA WELLS.
SEEPAGE PIT
DIAGRAM OF, sYSTEM
GRAVEL BACKFILL
CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION.
I CERTIFY THAT AM FAM[I.IAR WITH THE REQUIREMENTS Of GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE
DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE.
DATE
APPLICANT'S SIGNATURE
EQ-016(3-75)
TH-1
Lot 19
Not to Scale
TH-1
2-10-77
All Samples A
SA~DY SILT N/TRACE
GRAVEL
Brown, Moist
Cobble at 3'
--10.0'
SAND
Brown, Moist, Fine
to Medium Grained
18.0' TD
Groundwater Table Not Encoun%ered
This log represents subsurface
soil conditions within Lot 19,
Block 2, Valli-Vue Estates,
SW%, Section 14- T12N, R3W, S.M.
Anchorage, Alaska
[DWN' V~
~CKD~ DEB
~0a¥5: 2-11-77
. ~ 1"=3'
SANITARY S~4ER TEST HOLE
BAVARIA~ BUILDERS
A~;CHORAGE, AI~ASKA
GRID:
752109
A-01
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES_
Division of Environmental Services
On-Site Services Section
P.O. Box 196650 Anchorage, Alaska :99519'6650
343-4744
Parcel I.D. #
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
NAA#
GENERAL INFORMATION
Complete legal description
/3(oc~- ~, /-/~//i c/we
Location (site address or directions) ~'2d'd' ~z~. 7-f~ D,~,-~_
Property owner
Mailing address
Lending agency
Mailing address
Agent ~ory ~n~
Address
Day phone
Day phone
~Day phone
Unless otherwise requested, HAA will be held for pickup.
2. NUMBER OF BEDROOMS: ~
3. TYPE OF WATER SUPPLY:
NOTE:
Individual well
Community well / LP'~ -~P~~'~' ~''~' c/ /~Z'
Public water
If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system.
4. TYPE OF WASTEWATER DISPOSAL: · ·
Individual on-site
- -, Holding tank
Community on-site
r -- ' ' ' ' Public sewer , - - -
NOTE: If community wastewater system,'provide wr~?en confirmation from State ADEC
.... attesting to the legality and status'Of~s~e~i~'~;:i':i ,~:-: . ~;.'... ~:, '~¢:;.:;~: ..'~ ~:.- .'
STATEMENT OF INSPECTION BY ENGINEER .:~
AS certified by my seal affixed hereto and as of the validation date shown below, I verify that my:
investigation of this Health Authority Approval application shows ~hat the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance .with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection.
Phone ~ ~/~ - / '34-.5-
Date I! /7/?¥
DHHS SIGNATURE
·~ Approved .for ~
/
Disapproved.
Conditional approval for
By:
Additional Comments
The Municipality of Anchorage Department of Health and Human Services (DHHSI issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registerad in the State of Alaska,The DHHS does this as a courtesyto purchasers of homes
and their lending institutions in orderto satisfy certain federal and state requirements. Employees o1 DHHS do not
conduct Inspections or analyze data:before a certificate is Issued, The Municipality;of.An,chbr~ge is
responsible for errors' or or~issions I~ the pr,ofeSSional engineer's work..q.:_i.::
,,.,,..,.,,., .o^.. ...... .
:, :., ?;i,?,i;;::i?:-t:,; r~,.;, ,,:.,·,
Municipality of Anchorage
Department of Health and Human Services
HEALTH AUTHORITy APPROVAL CHECKLIST
Legal Description: Lo ~ I~,. [~ /lc ~., ball; U'u¢ #~ Parcel I.D.
FROM WELL LOG
A. Well Data
Well type '~/)"
Log present (Y/N)
Total depth
Sanitary seal (Y/N)
If A, B, or C, attach ADEC letter. ADEC water system number.
Date completed Driller
Cased to Casing height
Wires properly protected (Y/N)
AT INSPECTION
Date of test
Static water level
Well flow
Pump level1
SEPARATION DISTANCES FROM WELL TO:
Septic/holding tank on lot
Absorption field on lot
Public sewer main
Sewer service line
.g.p.m.
; On adjacent lots
; On adjacent lots
Public sewer manhole/cieanout
Petroleum tank
WATER SAMPLE RESULTS:
Coliform
Date of sample:
Nitrate Other bacteria
Collected by:
B. SEPTIC/HOLDING TANK DATA
Date installed II / ~ ~/? '7'
Cleanouts (Y/N)
High water alarm (Y/N)
Date of pumping
Tank size / ¢,oo' ~'~ / Compartments
Foundation cleanout (Y/N) 'i" .Depression (Y/N)
A~ Alarm tested (Y/N) /,,I, /~,
(. n.~ c(., ~ Pumper .N.
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO:
Well(s) on lot .~l. A,
To property line ~.5-
Surface water/drainage
On adjacent lots ~> ~_c,o' Foundation I
Absorption field -7.5-' Water main/service line
72026 (3/93)* Front
CONTINUED ON BACK PAGE
C. LIFT STATION N./¢.
Date installed
Size in gallons
Vent (Y/N) "Pump on" level at
High water alarm level
Meets MOA electrical codes (Y/N)
SEPARATION DISTANCE FROM LiFT STATION TO:
Well on lot __ On adjacent lots
Manufacturer
Manhole/Access (Y/N)
"Pump off" Level at
Cycles tested
Surface water
D, ABSORPTION FIELD DATA
Date installed II / ~ / ? ~' Soil rating (GPD/FF)
Length "/"/ Width .5' Gravel thickness
Total absorption area 3 ? ? Cleanout present (Y/N)
Date ot adequacy test N. A, ( n-~u~./ Results (pass/fail) --
Water level in absorption field before test
Peroxide treatment (past 12 months) (Y/N)
N
System type 5' ' ~-',
Total depth /.~
Depression over field (Y/N)
for 3 Bedrooms
After test O
If yes, give date hi, A,
SEPARATION DISTANCE FROM ABSORPTION FIELD TO:
Well on lot N,/~-,
To building foundation I g'
On adjacent lots ',> 3' d '
Surface water >. too '
On adjacent lots > ~ ~.,c, ' Properly line
To existing or abandoned system on lot
Cutbank ~, A. Water main/service line
Driveway, parking/vehicle storage area
Curtain drain
E. ENGINEER'S CERTIFICATION
I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in
the date of this inspection.
Signature '~~
Engineer"s Name
HAA Fee $ ,~ ,~'~
Date of Payment _ 1!/~3/~
Receipt Number 00 ~'"'?"¢'" '~ "7 "'~ ~
72-026 (3/93)° Back
CE-3589
Waiver Fee $
Date of Payment
Receipt Number
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
DIVISION OF ENVIRONMENTAL HEALTH
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL
OF ON-SITE SEWER AND WATER FACILITY
264-4720
Application Date _ ~/¢/'/~ ~"~
GENERAL INFORMATION
(a) Legal Description (include lot. block, subdivision, section, township, range)
Location (address or directions)
(b) Applicant Name ~'~I2~,'~U"~L- Telephone: Home ~l.J(~ . ¢~,~..~ Business
Applicant Address ~ ~,~,. 0~, /.~.~ ~ ~
(c) Applicant is (check one): Lending Institution []; Owner/builder []; Buyer []; Other [] (explain);
(d) Lending Institution Telephone
Address
(e) Real Estate Company and Agent g~e.,,-~ ,Le~/~_
Telephone ~"~ ~ ~/~"'~ ~'
(f) Mail the HAA to the following address:
TYPE OF RESIDENCE
Single-Family~[~' Multi-Family []
Number of Bedrooms .~
Other
WATER SUPPLV
Individual Wail [] Community/J~ Public
Note: If com m unity well system, must have written confirmation from the State Department of Environ mental Conservation
attesting to the legality and status.
4. SEWAGE DISPOSAL
Onsite~ Public [] Community [] Holding Tank []
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
Page I of 2 72-025 (1~z84)
ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health
Authority Approval shows that the on-site Water supply and/or wastewater disposa~ system is safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained
from the Municipality of Anchorage flies and from my investigation end inspection, the on-site water supply and/or
wastewater disposal system is in compliance with all Municipal and State codes, ordinances~ and regulations in effect on
the d~e of this inspection.
Name of Firr~ ~ ;--~~
Telephone ~-'7~ ' ~ ~'~
Approved ~ Disapproved Conditional
Terms of Conditional Approval
CAUTION
The M, uncipelity of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority
Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional
engineer registered in the State of Alaska. The DHEP does this es a courtesy to purchasers of homes and their lending
institutions m order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or
analyze da!a before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the
profe3$ional engineeFs work.
Page 2 of 2
MUNICIPAUTY OF ANCHORAGE (MOA)
HEALTH AUTHORITY APPROVAL (HAA)
CHECKLIST - FEBRUARY 1984
264-4720
Legal~_Descdpti,on: ,L_ O'~'
MUNICIPALITY OF ANCHORAGE
DEPT. OF HEALTH &
ENVIRONMENTAL PROTECr/O~,I
WELL DATA
Well Classification
Well Log Present (Y/N)
Total Depth
Static Water Level
Casing Height Above Ground
Electrical Wiring in Conduit (Y/N)
Separation Distances from Well:
To Septic/Holding Tank on Lot
To Nearest Edge of Absorption Reid on Lot
To Nearest Public Sewer Line
Cleanout/Manhole
Water Sample Collected by
IfA, B, C, D.E.C. Approved (Y/N)
Date Completed Yield
Cased to Depth of Grouting
Pump Set At
Sanitary Seal on Casing (Y/N)
Depression Around Wellhead (Y/N)
; On Adjoining Lots
; On Adjoining Lots
To Nearest Public Sewer
To Nearest Sewer Service Line on Lot
; Date
Y
Water Sample Test Results
Comments
B. SEPTIC/HOLDING TANK DATA
Date Installed ~/7/~'7
Standpipes (Y/N) 0 (~t~--- Air-tight Caps (Y/N)
Depression over Tank (Y/N)
Pumping/Maintenance Contract on File (Y/N)
Holding Tank High-Water Alarm (Y/N)
Separation Distances from Septic/Holding Tank:
To Water-Supply Well . ~
To Property Line
To Water Main/Service Line
Course
Size I0o0 No. of Compartmen~ts
Foundation Cleanout (Y/N)
Date Last Pumped
;for /'%"//,.'~
Temporary Holding Tank Permit (Y/N)
Comments
'To Building Foundation / Z/
To Disposal Field /~:~
To Stream, Pond, Lake, or Major Drainage
Page 1 of 2
72-026(11/84)
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata
Date Installed _
Width of Field
Square Feet of Absorption Area _
Depression over Field (Y/N)
Results of Last Adequacy Test
Separation Distance from Absorption Field:
To Water-Supply Well "~
To Building Foundation ,~'
Lot Fl 0 N .L~
To Water Main/Service Line
To Stream/Pond/Lake/or Major Drainage Course
To Driveway, Parking Area, or Vehicle Storage Area
Type of System Design
Length of Field ~'
Depth of Field
Gravel Bed Thickness
Standpipes Present (Y/N)
Date of Last Adequacy Test
To Property Line
To Existing or Abandoned System on
; On Adjoining Lots
To Cutbank (if present)
Comments
Dm LIFT STATION /~ ON ~-
Date Installed
Size in Gallons
"Pump On" Level at
High Water Alarm Level at
Tested for
Electrical Codes (Y/N)
Dimensions
Manhole/Access (Y/N)
"Pump Off" Level at
Vent (Y/N)
Pumping Cycles during Adequacy Test. Meets MOA
Comments
** Check Permitted Bedroom Rating Against HAA Request **
I certify that I have checked, veri~Od, or conformed to all MOA and HAA guidelines in effect on the date of this inspection.
Signed ~'~, ~~ · Date
Company ~"'~'~-¢
Receipt No.
Date of Payment
Amount: $ ~/~- c,~z_ Engineer's Seal
Page 2 of 2
72-026 (11/84}
I
CONSULTING ENGINEER
~203 W. 15th AVE "C" SUITE 203
ANCHORAGE, ALASKA 99501
TELEPHONE: 1907) 279-3916
SEPTIC
SYSTEM ADEQUACY TEST
LEGAL:
LOCATION:
OWNER:
RESIDENCE:
WATER SYSTEM:
SEPTIC SYSTEM:
LOT 19, BLOCK 2, VALLI VUE ESTATES
6266 WEST TREE DRIVE
ROGER K. DOUGHTY
SINGLE FAMLIY, THREE BEDROOMS
ON SITE WELL
FROM MUNICIPAL RECORDS:
TANK: GREER STEEL,
1000 GAL.
ABSORPTION SYSTEM:
ABSORPTION AREA:
SOIL RATING: 125,
INSTALLATION DATE:
TWO COMP.
TRENCH
580 SQ.FT.
150
MARCH 1977
DATE OF PUMPING: 8/3/85
DATE OF TEST:
9/9/85
WATER WAS ADDED TO THE TRENCH AT A STEADY
RATE OF 9 GALLONS PER MINUTE. THE WATER
LEVELS IN THE TANK AND SUMP WERE MONITORED
AT THE START OF THE TEST THE WATER LEVEL IN
THE TANK WAS 49 INCHES. AFTER THE ADDITION
OF550 GALLONS THE WATER LEVEL HAD NOT
CHANGED.
THE WATER LEVEL IN THE SUMP ROSE FROM 27
INCHES TO 54 INCHES DURING THE TEST. ONE HOUR
AFETR THE END OF THE FILLING PERIOD THE WATER
LEVEL WAS 50 INCHES.
THIS SYSTEM MEETS THE CODE REQUIREMENTS OF
THE MUNICIPALITY OF ANCHORAGE. THE TRENCH
ABSORBED 80 GALLONS IN ONE HOUR.
life of all septic systems depends on the local
groundwater levels that may fluctuate during the
water usage of the family being served by the
The operational
soil conditions,
year, and the
system. These conditions are outside the control of the evaluator
of this septic system. We can therefore not give any estimate of
how long the system will continue 5o meet the operational requi-
rements of the Municipality and State.